
fx-350EX fx-85EX fx-82EX
User’s Guide
CASIO Worldwide Education Website
Be sure to keep all user documentation handy for future reference.



Perform the following procedure when you want to initialize the calculator and return the calculation mode and setup (except for the Contrast setting) to their initial default settings. Note that this operation also clears all data currently in calculator memory. (RESET)(Initialize All)(Yes)
Safety Precautions
Battery

Before using the calculator, slide its hard case downwards to remove it, and then affix the hard case to the back of the calculator as shown in the illustration nearby. Turning Power On and Off Press to turn on the calculator. Press (OFF) to turn off the calculator.

Note: The calculator also will turn off automatically after approximately 10 minutes of non-use. Press the key to turn the calculator back on. Adjusting Display Contrast Display the Contrast screen by performing the key operation below: (SETUP)(Contrast). Next, use and to adjust contrast. After the setting is the way you want, press . Important: If adjusting display contrast does not improve display readability, it probably means that battery power is low. Replace the battery. Key Markings
Pressing the or key followed by a second key performs the alternate function of the second key. The alternate function is indicated by the text printed above the key.



Using Menus Some of the operations of this calculator are performed using menus. Menus are displayed by pressing or and then (SETUP). General menu operation operations are described below.


Specify the calculation mode that is suitable for the type of calculation you want to perform.


Before starting a calculation on the calculator, you should first use the operations in the table below to specify the formats that should be applied for calculation formula input and calculation result output.
*1 Decimal output is applied when these formats cannot be output for some reason. *2 All calculations, including fractions and functions are input in a single line. Same output format as that for models without Natural Textbook Display (S-V.P.A.M. models, etc.) Input/Output Format Display Examples





To change the calculator setup
Input/Output MathI/MathO◆; MathI/DecimalO; LineI/LineO; LineI/DecimalO Specifies the format to be used by the calculator for formula input and calculation result output. Angle Unit Degree◆; Radian; Gradian Specifies degree, radian or gradian as the angle unit for value input and calculation result display. Number Format Specifies the number of digits for display of a calculation result. Fix: The value you specify (from 0 to 9) controls the number of decimal places for displayed calculation results. Calculation results are rounded off to the specified digit before being displayed. Example: 1007(≈)* 14.286 (Fix 3) Sci: The value you specify (from 0 to 9) controls the number of significant digits for displayed calculation results. Calculation results are rounded off to the specified digit before being displayed. Example: 17(≈)* 1.4286 × 10-1 (Sci 5) Norm: Displays calculation results in exponential format when they fall within the ranges below.
Norm 1◆: 10-2 > |x|, |x| ≧ 1010, Norm 2: 10-9 > |x|, |x| ≧ 1010
Example: 1200(≈)* 5 × 10-3 (Norm 1), 0.005 (Norm 2) * Pressing (≈) instead of after inputting a calculation will display the calculation result in decimal form. Fraction Result ab/c; d/c◆ Specifies either mixed fraction or improper fraction for display of fractions in calculation results. Statistics On; Off◆ Specifies whether or not to display a Freq (frequency) column in the Statistics Mode Statistics Editor. Table f(x); f(x),g(x)◆ Specifies whether to use function f(x) only or the two functions f(x) and g(x) in the Table Mode. Decimal Mark Dot◆; Comma Specifies whether to display a dot or a comma for the calculation result decimal mark. A dot is always displayed during input. Note: When dot is selected as the decimal mark, the separator for multiple results is a comma (,). When comma is selected, the separator is a semicolon (;). Digit Separator On; Off◆ Specifies whether or not a separator character should be used in calculation results. MultiLine Font Normal Font◆; Small Font Specifies the display font size when LineI/LineO or LineI/DecimalO is selected for Input/Output.

Up to four lines can be displayed while Normal Font is selected, and up to six lines can be displayed with Small Font. To initialize calculator settings (except the Contrast setting) (RESET)(Setup Data)(Yes)
Basic Input Rules When you press the priority sequence of the input calculation will be evaluated automatically and the result will appear on the display.
4 × sin 30 × (30 + 10 × 3) = 120

*1 Input of the closing parenthesis is required for sin and other functions that include parentheses. *2 These multiplication symbols (×) can be omitted. *3 The closing parenthesis immediately before the operation can be omitted. Note
- When a multiplication sign is omitted immediately before an open
parenthesis or after a closed parenthesis. Example: 6 ÷ 2 1 + 2 6 ÷ 2 1 + 2 - When a multiplication sign is omitted immediately before a variable, a
constant, etc. Example: 2 ÷ 2 2 2 ÷ 2 2 Calculation Priority Sequence The priority sequence of input calculations is evaluated in accordance with the rules below. When the priority of two expressions is the same, the calculation is performed from left to right.

Note: When squaring a negative value (such as -2), the value being squared must be enclosed in parentheses (2). Since x2 has a higher priority than the negative sign, inputting 2 would result in the squaring of 2 and then appending a negative sign to the result. Always keep the priority sequence in mind, and enclose negative values in parentheses when required. Inputting an Expression Using Natural Textbook Format (MathI/MathO or MathI/DecimalO Only) Formulas and expressions that include fractions and/or special functions such as √ can be input in natural textbook format by using templates that appear when certain keys are pressed.
2 + 53 2 1. Press (). • This inputs a mixed fraction template.

() 532
6 and then change it to 1 + 7 6

Pressing (INS) in the above example causes 7
6 to be the argument
of the function input by the next key operation (√). Overwrite Input Mode (LineI/LineO or LineI/DecimalO only) In the overwrite mode, text you input replaces the text at the current cursor location. You can toggle between the insert and overwrite modes by performing the operations: (INS). The cursor appears as “” in the insert mode and as “” in the overwrite mode.
While MathI/MathO or MathI/DecimalO is selected for Input/Output on the setup menu, each press of will toggle the currently displayed calculation result between its fraction form and decimal form, its √ form and decimal form, or its π form and decimal form.
6𝜋= 0.5235987756 (MathI/MathO)
(π)6 1 6π ←→ 0.5235987756
2 + 2 × 3 = 5.913591358 = 6 + 2 3 (MathI/DecimalO) 223 5.913591358 ←→ 6 + 2 3 Regardless of what is selected for Input/Output on the setup menu, each press of will toggle the currently displayed calculation result between its decimal form and fraction form. Important
Fraction Calculations Note that the input method for fractions depends on the current Input/ Output setting on the setup menu.
2 3 + 11 2 = 13 6 (MathI/MathO) 23() 112 13 6 (LineI/LineO) 23112136

150 × 20% = 30 15020(%) 30 Calculate what percentage of 880 is 660. (75%)
660880(%) 75 Discount 3500 by 25%. (2625)
3500350025(%) 2625 Degree, Minute, Second (Sexagesimal) Calculations The syntax below is for inputting a sexagesimal value: {degrees} {minutes} {seconds} . Note that you must always input something for the degrees and minutes, even if they are zero.
2°20’30” + 9’30” = 2°30’00” 220300930 2°30’0” Convert 2°30’0” to its decimal equivalent. 2.5 (Converts decimal to sexagesimal.) 2°30’0” Multi-Statements You can use the colon character (:) to connect two or more expressions and execute them in sequence from left to right when you press .
3 + 3 : 3 × 3 33(:)33 6 9 Note: Inputting a colon (:) while LineI/LineO or LineI/DecimalO is selected for the Input/Output setting on the setup menu causes a newline operation to be performed. Using Engineering Notation
Transform the value 1234 to engineering notation, shifting the decimal mark to the right, and then to the left.
1234 1234 1.234×103
(←) 1.234×103
(←) 0.001234×106
Prime Factorization In the Calculate Mode, a positive integer no more than 10 digits long can be factored to prime factors.
To perform prime factorization on 1014
To re-display the unfactored value, press (FACT) or . Note: The types of values described below cannot be factored, even if they have 10 or fewer digits.
1234×100

Calculation History An and/or at the top of the display indicates that there is more calculation history content above and/or below. You can scroll through calculation history contents using and .
2 + 2 = 4 22 4 3 + 3 = 6 33 6 (Scrolls back.) 4
Note: Calculation history data is all cleared whenever you press , when you change to a different calculation mode, when you change the Input/ Output setting, or whenever you perform a RESET operation (“Initialize All” or “Setup Data”). Replay While a calculation result is on the display, you can press or to edit the expression you used for the previous calculation.
4 × 3 + 2 = 14 432 14 4 × 3 − 7 = 5 (Continuing) 7 5
Answer Memory (Ans) The last calculation result obtained is stored in Ans (answer) memory.
To divide the result of 14 × 13 by 7

123 + 456 = 579 789 − 579 = 210 123456 (Continuing) 789
Variables (A, B, C, D, E, F, M, x, y) You can assign values to variables and use the variables in calculations.
To assign the result of 3 + 5 to variable A
35(A) 8 To multiply the contents of variable A by 10
(Continuing) (A)10*1 80 To recall the contents of variable A

(A) 8 To clear the contents of variable A

*1 Input a variable as shown here: press and then press the key that corresponds to the desired variable name. *2 Pressing (RECALL) displays a screen that shows the values currently assigned to variables A, B, C, D, E, F, M, x, and y. On this screen, values are always displayed using the “Norm 1” Number Format. To close the screen without recalling a variable value, press . Independent Memory (M) You can add calculation results to or subtract results from independent memory. The “M” appears on the display when there is any value other than zero stored in independent memory.
To clear the contents of M
0(M) 0 To add the result of 10 × 5 to M
(Continuing) 105 50 To subtract the result of 10 + 5 from M
(Continuing) 105(M−) 15 To recall the contents of M
(Continuing) (RECALL)(M) 35 Note: Variable M is used for independent memory. You also can call M and use it in a calculation you are inputting. Clearing the Contents of All Memories Ans memory, independent memory, and variable contents are retained even if you press , change the calculation mode, or turn off the calculator. Perform the procedure below when you want to clear the contents of all memories. (RESET)(Memory)(Yes)
Pi π: π is displayed as 3.141592654, but π = 3.14159265358980 is used for internal calculations. Natural Logarithm Base e: e is displayed as 2.718281828, but e = 2.71828182845904 is used for internal calculations. sin, cos, tan, sin-1, cos-1, tan-1: Specify the angle unit before performing calculations.
sin 30° = 1
2 (Angle Unit: Degree) 30 1 2 sinh, cosh, tanh, sinh-1, cosh-1, tanh-1: Input a function from the menu that appears when you press (Hyperbolic Func)*1. The angle unit setting does not affect calculations.
*1 Depending on the calculation mode, you should press . ∘, r, g : These functions specify the angle unit. ° specifies degree, r radian, and g gradian. Input a function from the menu that appears when you perform the following key operation: (Angle Unit)*2. π/2 radians = 90° (Angle Unit: Degree)

(π)2(Angle Unit)(r) 90
*2 Depending on the calculation mode, you should press . , : Exponential functions. e5 × 2 = 296.8263182 (MathI/MathO) () 52 296.8263182 (LineI/LineO) () 52 296.8263182
log: Logarithmic function. Use to input logab as log (a, b). Base 10 is the default setting if you do not input anything for a. log101000 = log 1000 = 3 1000 3 log216 = 4 2(,) 16 4 The key also can be used for input, but only while MathI/MathO or MathI/DecimalO is selected for Input/Output on the setup menu. In this case, you must input a value for the base. log216 = 4 216 4 ln: Natural logarithm to base e. ln 90 (= loge 90) = 4.49980967 90 4.49980967
x2, x3, x-1: Powers, power roots, and reciprocals. (1 + 1)2+2 = 16 1122 16 (52)3 = 15625 5 15625 32 5 = 2 (MathI/MathO) () 532 2 (LineI/LineO) 5() 32 2 2 × 3 = 3 2 = 4.242640687 . . . (MathI/MathO) 23 3 2 (LineI/LineO) 23 4.242640687 Pol, Rec: Pol converts rectangular coordinates to polar coordinates, while Rec converts polar coordinates to rectangular coordinates.

(MathI/MathO) (Pol)2(,)2r=2, θ=45
To convert polar coordinates 2, 45° to rectangular coordinates (Angle Unit: Degree) (MathI/MathO) (Rec)2(,) 45x=1, y=1 x!: Factorial function. (5 + 3) ! = 40320 53(x!) 40320 Abs: Absolute value function. |2 − 7| × 2 = 10 (MathI/MathO) 272 10 (LineI/LineO) 272 10

Ran#: Function that generates a pseudo random number in the range of 0.000 to 0.999. The result is displayed as a fraction when MathI/MathO is selected for Input/Output on the setup menu. To obtain random three-digit integers
1000(Ran#) 459 (The result differs with each execution.) RanInt#: Function that generates a pseudo random integer between a specified start value and end value. To generate random integers in the range of 1 to 6
(RanInt)1(,) 6 2 (The result differs with each execution.) nPr, nCr: Permutation (nPr) and combination (nCr) functions. To determine the number of permutations and combinations possible when selecting four people from a group of 10
Permutations: 10(nPr) 4 5040 Combinations: 10(nCr) 4 210 Rnd: Using the Rnd function causes decimal fraction values of the argument to be rounded in accordance with the current Number Format setting. For example, the internal and displayed result of Rnd(10 ÷ 3) is 3.333 when the Number Format setting is Fix 3. Using the Norm 1 or Norm 2 setting cause the argument to be rounded off at the 11th digit of the mantissa part. To perform the following calculations when Fix 3 is selected for the number of display digits: 10 ÷ 3 × 3 and Rnd(10 ÷ 3) × 3 (MathI/DecimalO) (SETUP)(Number Format)(Fix)
1033 (Rnd) 1033
10.000 9.999
Perform the steps below to start a statistical calculation.
To select this type of statistical calculation: Press this key:
Single-variable (x) (1-Variable)
Paired-variable (x, y), linear regression (y=a+bx)
Paired-variable (x, y), quadratic regression (y=a+bx+cx2)
Paired-variable (x, y), logarithmic regression (y=a+b・ln(x))
Paired-variable (x, y), e exponential regression (y=a・e^(bx))
Paired-variable (x, y), ab exponential regression (y=a・b^x)
Paired-variable (x, y), power regression (y=a・x^b)
Paired-variable (x, y), inverse regression (y=a+b/x)

Note: When you want to change the calculation type after entering the Statistics Mode, perform the key operation (Select Type) to display the calculation type selection screen. Inputting Data with Statistics Editor Statistics Editor displays one, two, or three columns: single-variable (x), single variable and frequency (x, Freq), paired-variable (x, y), paired- variable and frequency (x, y, Freq). The number of data rows that can be input depends on the number of columns: 160 rows for one column, 80 rows for two columns, 53 rows for three columns. Note

(Select Type)(y=a+b・ln(x))

170173179 666875
Important: All data currently input in the Statistics Editor is deleted whenever you exit the Statistics Mode, switch between the single-variable and a paired-variable statistical calculation type, or change the Statistics setting on the setup menu. To delete a line: In the Statistics Editor, move the cursor to the line that you want to delete and then press . To insert a line: In the Statistics Editor, move the cursor to the location where you want to insert the line and then perform the following key operation: (Editor)(Insert Row). To delete all Statistics Editor contents: In the Statistics Editor, perform the following key operation: (Editor)(Delete All). Displaying Statistical Values Based On Input Data
From the Statistics Editor: (1-Variable Calc or 2-Variable Calc) From the statistical calculation screen: (1-Variable Calc or 2-Variable Calc)



Obtaining Statistical Values from Input Data You can use the operations in this section to recall statistical values assigned to variables (σx, Σx2, etc.) based on the data you input with the Statistics Editor. You can also use the variables in calculations. The operations in this section are performed on the statistical calculation screen that appears when you press while the Statistics Editor is displayed. Supported statistical variables and the keys you should press to recall them are shown below. For single-variable statistical calculations, the variables marked with an asterisk (*) are available. Summation: Σx*, Σx2*, Σy, Σy2, Σxy, Σx3, Σx2y, Σx4
x*, σ2
x*, s2
(Variable) to , to Minimum Value: min(x)*, min(y) / Maximum Value: max(x)*, max(y)
When the single-variable statistical calculation is selected: (Min/Max) , When a paired-variable statistical calculation is selected: (Min/Max) to First Quartile: Q1* / Median: Med* / Third Quartile: Q3* (For single-variable statistical calculations only)
(Regression) to Regression Coefficients for Quadratic Regression: a, b, c / Estimated Values: 𝑥1, 𝑥2, 𝑦
(Regression) to • 𝑥, 𝑥1, 𝑥2 and 𝑦 are commands of the type that take an argument immediately before them. Ex 2: To input the single-variable data x = {1, 2, 2, 3, 3, 3, 4, 4, 5}, using the Freq column to specify the number of repeats for each items {xn; freqn} = {1;1, 2;2, 3;3, 4;2, 5;1}, and calculate the mean. (SETUP)(Statistics)(On) (Select Type)(1-Variable)

12345 1232
(Variable)(𝑥−) 3 Ex 3: To calculate the logarithmic regression correlation coefficients for the following paired-variable data and determine the regression formula: (x, y) = (20, 3150), (110, 7310), (200, 8800), (290, 9310). Specify Fix 3 (three decimal places) for results. (SETUP)(Statistics)(Off) (SETUP)(Number Format)(Fix) (Select Type)(y=a+b・ln(x))

20110200290 3150731088009310

(Regression)(r) 0.998 (Regression)(a) -3857.984 (Regression)(b) 2357.532
Calculating Estimated Values Based on the regression formula obtained by paired-variable statistical calculation, the estimated value of y can be calculated for a given x-value. The corresponding x-value (two values, x1 and x2, in the case of quadratic regression) also can be calculated for a value of y in the regression formula.
Ex 4: To determine the estimate value for y when x = 160 in the regression formula produced by logarithmic regression of the data in Ex 3. Specify Fix 3 for the result. (Perform the following operation after completing the operations in Ex 3.)
160(Regression)(𝑦) 8106.898
The Table Mode generates a number table based on one or two functions.
g 𝑥= 𝑥2 −1
2 for the range -1 ≦ 𝑥 ≦ 1, incremented in steps of 0.5

(x)12

(x)12

110.5

2 and

The calculator will display an error message whenever an error occurs for any reason during a calculation. While an error message is displayed, press or to return to the calculation screen. The cursor will be positioned at the location where the error occurred, ready for input. To clear the error message: While an error message is displayed, press to return to the calculation screen. Note that this also clears the calculation that contained the error. Error Messages
function, make sure that the memory or variable value is within the allowable range for the function. Stack ERROR
of the stack. →Try splitting the calculation into two or more parts. Syntax ERROR
Math ERROR

→Narrow the table calculation range by changing the Start, End, and
Step values, and try again.
Before Assuming Malfunction of the Calculator...
1. Check the calculation expression to make sure that it does not contain any errors. 2. Make sure that you are using the correct mode for the type of calculation you are trying to perform. 3. If the above steps do not correct your problem, press the key. • This will cause the calculator to perform a routine that checks whether calculation functions are operating correctly. If the calculator discovers any abnormality, it automatically initializes the calculation mode and clears memory contents. 4. Return the calculation mode and setup (except for the Contrast setting) to their initial default settings by performing the following operation: (RESET)(Setup Data)(Yes).
A low battery is indicated by a dim display, even if contrast is adjusted, or by failure of figures to appear on the display immediately after you turn on the calculator. If this happens, replace the battery with a new one. Important: Removing the battery will cause all of the calculator’s memory contents to be deleted.

Calculation Range and Precision

Calculation Range ±1 × 10-99 to ±9.999999999 × 1099 or 0


In general, ±1 at the 10th digit for a single calculation. Precision for exponential display is ±1 at the least significant digit. Errors are cumulative in the case of consecutive calculations.
Degree 0 ≦ |x| < 9 × 109
sinx cosx
Radian 0 ≦ |x| < 157079632.7
Gradian 0 ≦ |x| < 1 × 1010
Degree Same as sinx, except when |x| = (2n−1) × 90.
Radian Same as sinx, except when |x| = (2n−1) × π/2.
Gradian Same as sinx, except when |x| = (2n−1) × 100.
sin-1x, cos-1x 0 ≦ |x| ≦ 1
tan-1x 0 ≦ |x| ≦ 9.999999999 × 1099
sinhx, coshx 0 ≦ |x| ≦ 230.2585092
sinh-1x 0 ≦ |x| ≦ 4.999999999 × 1099
cosh-1x 1 ≦ x ≦ 4.999999999 × 1099
tanhx 0 ≦ |x| ≦ 9.999999999 × 1099
tanh-1x 0 ≦ |x| ≦ 9.999999999 × 10-1
logx, lnx 0 < x ≦ 9.999999999 × 1099
10x -9.999999999 × 1099 ≦ x ≦ 99.99999999
ex -9.999999999 × 1099 ≦ x ≦ 230.2585092
𝑥 0 ≦ x < 1 × 10100
x2 |x| < 1 × 1050
x-1 |x| < 1 × 10100 ; x ≠ 0
𝑥 3 |x| < 1 × 10100
x! 0 ≦ x ≦ 69 (x is an integer)
nPr 0 ≦ n < 1 × 1010, 0 ≦ r ≦ n (n, r are integers) 1 ≦ {n!/(n−r)!} < 1 × 10100
nCr 0 ≦ n < 1 × 1010, 0 ≦ r ≦ n (n, r are integers) 1 ≦ n!/r! < 1 × 10100 or 1 ≦ n!/(n−r)! < 1 × 10100
Pol(x, y) |x|, |y| ≦ 9.999999999 × 1099
𝑥2 + 𝑦2 ≦ 9.999999999 × 1099
Functions Input Range · tanx

Rec(r, θ) 0 ≦ r ≦ 9.999999999 × 1099
|a|, b, c < 1 × 10100 ; 0 ≦ b, c The display seconds value is subject to an error of ±1 at the second decimal place.
|x| < 1 × 10100
Decimal ↔ Sexagesimal Conversions 0°0’0” ≦ |x| ≦ 9999999°59’59”
x > 0: -1 × 10100 < ylogx < 100 x = 0: y > 0
y > 0: x ≠ 0, -1 × 10100 < 1/x logy < 100 y = 0: x > 0
𝑚 (m ≠ 0; m, n are integers)
a b/c Total of integer, numerator, and denominator must be 10 digits or less (including separator symbol).
RanInt#(a, b) a < b; |a|, |b| < 1 × 1010; b − a < 1 × 1010
fx-82EX: AAA-size battery R03 (UM-4) × 1 fx-350EX: AAA-size battery LR03 (AM4) × 1 fx-85EX: Built-in solar cell; button battery LR44 × 1 Approximate Battery Life (based on one hour of operation per day):
fx-82/85EX: 2 years fx-350EX: 1 year Power Consumption: 0.0006 W (fx-82/350EX) Operating Temperature: 0°C to 40°C (32°F to 104°F) Dimensions:
fx-82/350EX: 13.8 (H) × 77 (W) × 165.5 (D) mm 1/2” (H) × 3” (W) × 61/2” (D) fx-85EX: 11.1 (H) × 77 (W) × 165.5 (D) mm 3/8” (H) × 3” (W) × 61/2” (D)
°’ ” · °’ ” · xy

Approximate Weight:
fx-82/350EX: 100 g (3.5 oz) including the battery fx-85EX: 90 g (3.2 oz) including the battery
How can I change a fraction form result produced by a division operation to decimal form?
→While a fraction calculation result is displayed, press . To have
calculation results initially appear as decimal values, change the setup menu Input/Output setting to MathI/DecimalO. What is the difference between Ans memory, independent memory, and variable memory?
→Each of these types of memory acts like “containers” for temporary
storage of a single value. Ans Memory: Stores the result of the last calculation performed. Use this memory to carry the result of one calculation on to the next. Independent Memory: Use this memory to totalize the results of multiple calculations. Variables: This memory is helpful when you need to uses the same value multiple times in one or more calculations. What is the key operation to take me from the Statistics Mode or Table Mode to a mode where I can perform arithmetic calculations?
→Press (Calculate). How can I return the calculator to its initial default settings?
→Perform the following operation to initialize calculator settings (except
the Contrast setting): (RESET)(Setup Data)(Yes). When I execute a function calculation, why do I get a calculation result that is completely different from older CASIO calculator models?
→With a Natural Textbook Display model, the argument of a function that
uses parentheses must be followed by a closing parenthesis. Failing to press after the argument to close the parentheses may cause unwanted values or expressions to be included as part of the argument. Example: (sin 30) + 15 (Angle Unit: Degree) Older (S-V.P.A.M.) Model: 3015 15.5 Natural Textbook Display Model: (LineI/LineO) 3015 15.5 Failure to press here as shown below will result in calculation of sin

This mark applies in EU countries only.
Printed in China SA1412-A
© 2015 CASIO COMPUTER CO., LTD.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.