EN
Bomann logo
Official user manual

Bomann VS 175

24 pages·1.6 MB·Refrigeration and freezing·PDF·ENFRITNLJA
Bomann VS 175
Table of Contents 2 sections 页 1 · 页 2 ShowHide
Page 1 of the Bomann VS 175 user manual — O VERVIEW
Page 1 · click to enlarge
Page 1

T ABLE O F C ONTENT

OVERVIEW 2 DISPOSAL OF USED DEVICES 2 IMPORTANT USE AND SAFETY INSTRUCTIONS 3 General safety precautions 3

Risk of injury 3

PRODUT DESCRIPTION 4 Control Panel 4

INSTALLATION 5 Location 5

REVERSE THE DOOR OPENING 6 STARTUP / OPERATION 8 Prior to first use 8

What if . . . Troubleshooting 10

O VERVIEW

Please read this user manual thoroughly before first time operation. It includes im- portant information with regard to installation, operation and maintenance of the device. Improper use may cause hazardous situations, especially for children. Keep this manual for future reference. Pass it on to any future owner of this product. In case of any doubt regarding questions or topics which are not extensively described in this manual, please contact your distributor or a specialist. DISPOSAL OF USED DEVICES

This product is marked in accordance with the European waste regulation

  • 2002 / 96 / EC - WEEE It regulates the proper disposal of the product. Environmentally friendly disposal will prevent possible negative consequences to health caused by improper disposal. This symbol on the product or its packaging indicates that this product must not be disposed of with the regular household waste. The user has to return the product to a collection point for the recycling of electric and electronic equipment. The disposal must comply with the local regulations in place. For further information please contact your local authorities or waste collection service. Disable waste equipment before disposal:
  • Disconnect the mains plug from the wall socket.
  • Disconnect the plug from the mains cable.
  • Remove or disable any existing spring or latch locks. This will prevent children from locking themselves (risk of suffocation!) or from getting into perilous situations. Children might not understand the risks that arise from handling household devices. Therefore, observe children and make sure they do not play with the device.
Show 12 more labels / short text on this page
Coolant 3 · Intended use 3 · Unpacking 3 · Specifications 5 · Electrical connection 6 · Turning on 8 · Storing food 8 · Defrosting 9 · Operating noise 9 · Turning off 9 · Repairs 10 · 2 03/2012
Page 2 of the Bomann VS 175 user manual — I MPORTANT U SE A ND S AFETY I NSTRUCTIONS
Page 2 · click to enlarge
Page 2

I MPORTANT U SE A ND S AFETY I NSTRUCTIONS

  • General safety precautions All safety information in this user manual are marked with a warning symbol. They indicate possible dangers precociously. It is imperative to read and follow these information.
  • Do not touch the plug at the mains cable with wet or moist hands when connecting or disconnecting. Risk of death by electric shock!
  • In case of emergency, unplug the device immediately.
  • Hold the plug when disconnecting the mains cable; do not pull the cable.
  • Disconnect the plug before cleaning or servicing.
  • Regularly check the device and cable for signs of damage. Do not continue to operate the device in case of damage.
  • A damaged mains cable must be replaced by the manufacturer or a technician and without any delay. Do not use the device with a damaged cable or plug.
  • Do not repair the device by yourself. Please contact authorized personnel. In order to avoid hazards. A damaged mains cable must be replaced with an equivalent cable by the manufacturer or qualified specialist.
  • Except for cleaning and maintenance work described in this manual, no other alterations of this device must be executed.
  • Do not place vases or other containers filled with liquids on the device. Risk of injury!
  • So that you can disconnect the appliance quickly in event of an emergency, do not use extension cables.
  • This device may not be operated by children or persons with physical, sensory or mental abilities or lack of experience and knowledge, unless they are supervised or guided.
  • Children should be supervised to ensure that they do not play with the device.
  • Transport the unit never with content.
  • WARNUNG
  • Packaging materials (e.g. plastic bags, polystyrene) are dangerous for children. Risk of suffocation! Keep packaging materials out of reach of children.
  • Containers with flammable gases or liquids can leak due to cold ambient temperatures. Risk of explosion! Do not store combustible materials such as aerosol cans or refill cartridges for lighters in your device. Coolant
  • CAUTION The coolant circuit of this device contains the refrigerant Isobutane (R600a), a natural gas that is flammable and of high environmental compatibility. Make sure no parts of the Coolant circuit gets damaged during transport and installation of the device. If the coolant circuit is damaged:
  • it is imperative to avoid any open flames or ignition source.
  • thoroughly air the room in which the device is installed. Intended use
  • This device is intended for private use. It is suitable for cooling and storing food.
  • The manufacturer is not reliable for any damage resulting from improper or other then intended use.
  • For safety reasons, alterations or modifications of the device are prohibited.
  • Please keep in mind that the manufacturer is not reliable for any damage resulting from commercial or any other use then freezing food. Unpacking The packaging must be undamaged. Check the device for any possible transport damage. Do not install a damaged device. In case of damage, please contact your distributor.

3 03/2012

Page 3 of the Bomann VS 175 user manual — 页 1
Page 3 · click to enlarge
Page 3
Bomann VS 175 — 页 1 diagram (page 3)
Fig. 1
Bomann VS 175 — 页 1 diagram (page 3)
Fig. 2
Bomann VS 175 — 页 1 diagram (page 3)
Fig. 3
Bomann VS 175 — 页 1 diagram (page 3)
Fig. 4
Bomann VS 175 — 页 1 diagram (page 3)
Fig. 5
Page 4 of the Bomann VS 175 user manual — 页 2
Page 4 · click to enlarge
Page 4
Bomann VS 175 — 页 2 diagram (page 4)
Fig. 6
Bomann VS 175 — 页 2 diagram (page 4)
Fig. 7
Page 5 of the Bomann VS 175 user manual — 页 2
Page 5 · click to enlarge
Page 5
  • IMPORTANT
  • Do not expose the device to direct sunlight.
  • Do not place near heaters, next to a stove or any other heat sources.
  • Do not use the device outdoors.
  • Only install at a location with an ambient temperature suitable for the climate class of the device. For information on the climate class, please refer to chapter “Specifications“ or to the rating label located in the interior or on the rear side of the device.
  • Avoid installation at locations with high humidity (e.g. outdoors, bathroom), as metal parts would be susceptible to corrosion under such circumstances.
  • Do not place the device near volatile or combustible materials (e.g. gas, fuel, alcohol, paint, etc.) and in rooms which may have poor air circulation (e.g. garages).
  • Only place on a steady and safe surface.
  • If the device is not horizontally leveled, adjust the feet accordingly.
  • Electrical connection The kind of current (AC) and the voltage must be conform with the data of the rating label, located inside or outside on the back of the unit. In case of heavy voltage fluctuations, it is recommended to use an automatic alternating current regulator. The plug, together with the grounding conductor, must fit into the wall socket. The mains plug must be freely accessible. Mains cable
  • Do not extend or roll up the cable during operation.
  • Also, the cable must not be near the compressor on the rear side, since latter one gets hot during operation. In case of any contact, the isolation would be damaged resulting in electric leakage.
  • The use of extension cables is not recommended.
  • Do not connect the device to the mains with wet hands.
  • Install the device for the wall socket to be freely accessible. Leveling The appliance should be level in order to eliminate vibration. To make the appliance level, it should be upright and both adjusters should be in stable contact with the floor. You can also adjust the level by unscrewing the appropriate level adjustment in the front (use your fingers or a suitable spanner). R EVERSE T HE D OOR O PENING

If required, the door opening can be moved from the right (supplied condition) to the left side.

Socket driver (8 mm), (10 mm)

Putty knife or thin-blade screwdriver

1. Remove the three screws at the rear and the two screws at the top of the Larder Freezer and remove the lid.
5. Lay the Upright Freezer backward. Remove the bottom hinge bracket using an 8 mm socket or spanner.
Bomann VS 175 — 页 2 diagram (page 5)
Fig. 8
Bomann VS 175 — 页 2 diagram (page 5)
Fig. 9

Cross-shaped screwdriver · 6 03/2012

Page 6 of the Bomann VS 175 user manual — 页 2
Page 6 · click to enlarge
Page 6
2. Use an 8 mm spanner to remove the top bracket.
6. Remove the pin and replace on the opposite side. Using a 10 mm socket or spanner.
Bomann VS 175 — 页 2 diagram (page 6)
Fig. 10
Bomann VS 175 — 页 2 diagram (page 6)
Fig. 11

Reattach bottom bracket to the Upright Freezer. Re- place leveling feet. Stand upright and replace door.

7. Insert top hinge bracket into the recess on top of the door. Bolt into place using the three bolts removed earlier.
3. Lift the hinge bracket out of the recess in the door.
Bomann VS 175 — 页 2 diagram (page 6)
Fig. 12
Bomann VS 175 — 页 2 diagram (page 6)
Fig. 13
8. Remove blanking plates from the door handle to reveal screws. Remove the two screws that secure the handle,
4. Remove the pin from the bracket with a 10mm spanner/socket. Replace in the same hole through the other side. Remove the door.
Bomann VS 175 — 页 2 diagram (page 6)
Fig. 14
Bomann VS 175 — 页 2 diagram (page 6)
Fig. 15
9. Cover the holes left by the removed screws with the blanking plates. Re-secure the door handle on the other side. Cover screws with the blanking plates.
11. Check the door is aligned horizontally and vertically. Re-adjust the adjustable feet.
Bomann VS 175 — 页 2 diagram (page 6)
Fig. 16
Bomann VS 175 — 页 2 diagram (page 6)
Fig. 17
10. Replace and secure the lid of the Upright Freezer with the two top screws and the three rear screws from step 1.
Bomann VS 175 — 页 2 diagram (page 6)
Fig. 18

7 03/2012

Page 7 of the Bomann VS 175 user manual — Prior to first use
Page 7 · click to enlarge
Page 7

Check if the door is arranged vertical as well as horizontal, so that a smooth opening and closing of the door is ensured. STARTUP / OPERATION

Prior to first use

ATTENTION After transport, the device should be left standing for 4 hours in order for the oil to be collected in the compressor. Nonobservance could cause damage to the compressor and hence result in failure of the device. This would void your warranty claim. • Clean the interior of the device including all accessory parts located inside. Connect the device to the mains supply

  • IMPORTANT
  • The device must be earthed properly. For this purpose the plug of the mains cable has been fitted with the intended lead.
  • Contact an electrician if the plug does not fit in the wall socket.
  • In case you disconnect the device or in case of power failure: Wait for 5 minutes before restarting the device. Turning on Turn on the device by connecting the plug to a wall socket. The thermostat control panel controls the temperature inside the freezer compartment and is located on the top cover plate. Thermostat of the refrigerator If you press the

button, you can select the temperature ranging from +2°C to +8°C. If you press the

  • button once, the temperature will increase or decrease, until the required temperature is displayed. Please keep in mind that the temperature changes with the ambient temperature (of the location), with the frequency of opening the door and the amount of food in the device. During initial operation, set the temperature control to the highest setting first, until the device has reached the desired operating temperature. Afterwards it is recommended to turn the control back to a medium setting, correcting the temperature at a later point would then be easier. Super Cool With pressing the button “Super Cool” the device is working with a faster cooling procedure. The LED „Super Cool“ is lightening. Storing food Note: Always store food covered or packed in order to prevent drying-out and transfer of odor or taste onto other food items. You may pack the food with:
  • Polyethylene plastic bags or foil
  • Plastic containers with a lid
  • Special elasticated plastic covers
  • Aluminum foil The following safety precautions are recommended
  • The device is suitable for storing fresh food and drinks.
  • Store fresh packed items on the glass shelves and fresh fruits and vegetables in the vegetable box.
  • Place bottles in the door storage rack.
  • Store meat well packed and only for 2 to 3 days. Avoid contact with cooked dishes.
  • Let warm food cool down before putting it in the device.
  • Keep a space between the single items for air circulation.

or · or · 8 03/2012

Page 8 of the Bomann VS 175 user manual — NORMAL NOISE
Page 8 · click to enlarge
Page 8

Defrosting The device has a automatic defrosting system. During defrosting the water drops drain off at the rear side of the cooling chamber. The water running through a flume, is collected in a container underneath the compressor, where it will evaporate. Make sure the flume does not get clogged. Clean it carefully with a pipe cleaner or knitting needle. A light formation of ice on the rear side during operation is nor- mal. Operating noise

TYPE OF SOUND CAUSE/ SOLUTION

Mumbling Caused by the compressor during its operation. This is stronger when it turns on or off.

Liquid sounds Caused by the circulation of the refrigerant in the device.

NORMAL NOISE

Click sounds The temperature control turns the compressor on or off.

  • Disturbing noises Vibration of the shelves or cooling coils – check if those are securely fastened. Turning off Disconnect the plug or unscrew the fuse in order to turn off the device. If the device will not be operated for a longer period of time:
  • Remove the entire food from the device.
  • Disconnect the plug or turn off / unscrew the fuse.
  • Thoroughly clean the device (refer to chapter of “Cleaning and Care”).
  • Keep the door open in order to prevent bad odors. T IPS F OR E NERGY S AVING
  • Disconnect the plug if you do not use the device.
  • Do not install the device near stoves, heaters or other heat sources. In case of higher ambient temperatures, the compressor will run more frequently and longer.
  • Ensure sufficient ventilation at the bottom and rear side of the device. Never block any ventilation openings.
  • Allow warm dishes to cool down before putting them in the device.
  • Do not open the door longer then necessary.
  • Avoid opening all freezer compartments at the same time.
  • Make sure that the temperature in the freezer does not rise above -18°C.
  • The device should be defrosted regularly.
  • Always keep the condenser – metal grid on the rear side (if existing) – clean.
  • Make sure the door sealing is in good order for the door to close properly. M AINTENANCE A ND C LEANING

Cleaning and care For hygienic reasons, clean the interior and accessory parts regularly.

  • WARNING
  • Always disconnect the plug or turn off/ unscrew the fuse before cleaning. Pull the plug and not the cable.
  • Do not use steam cleaners for cleaning the device; moisture could enter electrical components. Risk of electric shock! Hot steam could damage the plastic parts. The device must be dry before restarting operation.
  • Essential oils and organic solvents, such as the juice of lemon or orange skin, butanoic acid or cleaning agents containing acetic acid can damage plastic parts. Prevent contact of any part with such substances. Do not use abrasive cleaning agents.

9 03/2012

Page 9 of the Bomann VS 175 user manual — 页 2
Page 9 · click to enlarge
Page 9
  • Pls. do as follows:
  • Remove all food and keep covered at a cool location.
  • Use warm water and a mild detergent for cleaning the interior (including rear side and bottom).
  • After thorough drying, restart operation.
  • Clean the condenser - metal grid on the rear side (if existing) once a year, using a soft brush or vacuum cleaner.
  • Before changing the light bulb, switch off the appliances and unplug it, or pull the fuse or the circuit breaker.
  • Light bulb data: 220-240V
  • Unplug the mains plug.
  • Press the bulb in the center with finger. Before changing the light bulb, either the refrigerator or disconnect the electricity leading into the refrigerator into the refrigerator at the main power supply. Failure to do so should result in electrical shock or personal injury.
Bomann VS 175 — 页 2 diagram (page 9)
Fig. 19
  • Remove the light cover out by one hand while pressing the middle of the light cover by force with the other hand.
  • Replace with a 10 watt (or less than 10 watt) light bulb that is of the same shape and size.
  • Replace the light cover. Repairs

WARNING Servicing of electric devices must be conducted by qualified experts only. Incorrect or improper repairs constitute a risk for the user and will void the warranty! What if . . . Troubleshooting The design of the device ensures a trouble-free operation as well as a long life cycle. Nevertheless, if any defect occurs during operation, please check if it is caused by improper operation. The following problems can be solved by you by checking for the possible cause. PROBLEM POSSIBLE CAUSE SOLUTION The device is not working properly or at all

Connect the plug properly to the socket, turn on the fuse, and contact a technician if necessary. Check the settings. Check the ambient temperature. Arrange the food or shelves and/or drawers properly. Clear the ventilation slits, install the device freely Appliances cools too much

Is the plug securely connected to the mains? Has the safety mechanism of the wall socket been triggered? Is the temperature control properly set? Is the place unqualified? Do food items or shelves and/or drawers prevent the door from closing properly? Is the ventilation of the device hedged?

Temperature is set too cold. Turn the temperature regulator to a warmer setting temporarily.

The food is too warm.

Temperature is not properly adjusted. Door was open for an extended period. A large quantity of warm food was placed in the appliances within the last 24 hours.

Please refer to the “StartUp” section. Open the door only as long as necessary. Turn the control panel to a colder setting temporially.

10 03/2012

Page 10 of the Bomann VS 175 user manual — 页 2
Page 10 · click to enlarge
Page 10

The appliance is near a heat source. Please refer to the “Installation Location” section. Light does not work

The light bulb is defective. Please look in the “Changing the light bulb” section. Loud noise during opera- tion

Adjust the feet accordingly. Liquid flow sounds in the cooling circuit are normal. Water on the bottom

Does the device not stand vertical or hori- zontal?

Is the temperature control set properly?

Check the temperature settings.

www.bomann.de

  • Distribution: C. Bomann GmbH
  • Heinrich-Horten-Str. 17
  • D-47906 Kempen

11 03/2012

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
The device is not working properly or at allIs the plug securely connected to the mains? Has the safety mechanism of the wall socket been triggered? Is the temperature control properly set? Is the place unqualified? Do food items or shelves and/or drawers prevent the door from closing properly? Is the ventilation of the device hedged?Connect the plug properly to the socket, turn on the fuse, and contact a technician if necessary. Check the settings. Check the ambient temperature. Arrange the food or shelves and/or drawers properly. Clear the ventilation slits, install the device freely p.9
Appliances cools too muchTemperature is set too cold.Turn the temperature regulator to a warmer setting temporarily. p.9
The food is too warm.Temperature is not properly adjusted. Door was open for an extended period. A large quantity of warm food was placed in the appliances within the last 24 hours.Please refer to the “StartUp” section. Open the door only as long as necessary. Turn the control panel to a colder setting temporially. p.9

Ask about the Bomann VS 175

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Bomann VS 175

Be the first to ask — other owners or our team will answer.

Original document

Bomann VS 175 manual PDF

24 pages·1.6 MB·Refrigeration and freezing·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…