The complete installation set and replacement filters can be obtained from specialist outlets. The corresponding accessory numbers can be found at the end of these operating instructions. K The extractor-hood fan extracts the
If you have any questions or if a fault occurs, please call Customer Service. (See list of Customer Service representatives). When you call, please quote the following:
kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen. K The grease filter absorbs the grease
Enter the relevant numbers into the box above. The E-Nr. (product no.) and FD (production date) are shown on the nameplate which can be seen inside the extractor hood after the filter frame has been detached. The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework.
particles in the kitchen vapours. K The activated carbon filter binds the
odorous substances. If no activated carbon filter is installed, it is not possible to bind the odorous substances in the cooking vapours.
kitchen vapours and conveys them through the grease filter into the atmosphere. K The grease filter absorbs the solid
versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. K This extractor hood complies with all
particles in the kitchen vapours. K The kitchen is kept almost free of grease
and odours. D When the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion. Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar). This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air-inta- ke/exhaust-air wall box or by other techni- cal measures, such as reciprocal interlocking, etc. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter.
relevant safety regulations. Repairs should be carried out by qualified technicians only. Improper repairs may put the user at considerable risk. K Before using your appliance for the first
time, please read these Instructions for Use carefully. They contain important information concerning your personal safety as well as on use and care of the appliance. K Please retain the operating and
installation instructions for a subsequent owner.
K This appliance is labelled
in accordance with European Directive 2002/96/EG concerning used electrical and electronic appliances (waste electrical and electronic equipment – WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU.
for this operating mode (see Filters and maintenance).
Pull-out vapour extractor · Light switch


Filters and maintenance
Do not use the appliance if damaged. The appliance may be connected to the mains by a qualified technician only. If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his custo- mer service or a similarly qualified person in order to prevent serious injury to the user. Dispose of packaging materials properly (see Installation instructions). This extractor hood is designed for domestic use only. Light bulbs must always be fitted when the extractor hood is in use. Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading. Never operate the extractor hood without a grease filter. Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended. Never allow children to play with the appliance. Do not let adults or children operate the appliance unsupervised: – if they are mentally or physically unable
Various types of grease filter can be used to absorb the grease contained in the vapours produced during cooking. The filter frame must be detached before the grease filter can be renewed.
The most effective method of removing vapours produced during cooking is to: K Switch the ventilator ON
as soon as you begin cooking. K Switch the ventilator OFF
Detaching and re-attaching the filter frame: Detaching the frame: 1. Open the cupboard door. 2. Place your fingers in the recessed grips in the inspection window, push the filter frame towards the front and then pull it all the way out.
a few minutes after you have finished cooking. Switching the ventilator ON: 1. Pull out the vapour extractor tray. K The ventilator is operating. 2. Select the required ventilator power level. Operating controls on different models:

Re-attaching the frame: 1. Insert the filter frame into the housing and push it in as far as it will go. 2. Close the cupboard door.
Metal grease filter: The filter mat is made of non-combustible metal.
to use the appliance safely and correctly, – if they don’t have the knowledge and
experience to use the appliance safely and correctly. Do not flambé food directly under the extractor hood.
Risk of grease filter catching fire due ! to flames. The hotplates must always be covered with a utensil. Restrictions apply to the use of the extractor hood over a solid-fuel burner (coal, wood, etc.). (See Installation instructions).
as far as it will go. Note: The next time that the tray is pulled out, the ventilator will start up at the power level to which it was last set.
Light:
Cleaning the metal filter: Under normal operating conditions (1 to 2 hours per day), the metal grease filter will require cleaning after 8 to 10 weeks.
Gas hobs / Gas cookers Do not use all the gas hotplates simultaneously for a prolonged period (max. 15 minutes) at maximum thermal load, otherwise there is a risk of burns if the housing surfaces are touched or a risk of damage to the extractor hood. If the extractor hood is situated over a gas hob, operate the hood at maximum setting if three or more gas hotplates are operated simultaneously.
the metal grease filter must be cleaned 1 x a month. K The filters can be cleaned in a dish-
washer. It is however possible that they will become slightly discoloured. K The filter must be placed loosely, and
NOT wedged, in the dishwasher. Important: Metal filters that are saturated with grease should not be washed together with other dishes etc.

Cleaning and care
K When cleaning the filters by hand, soak
Clean the operating buttons with a mild soapy solution and a soft, damp cloth only. Do not use stainless-steel cleaner to clean the operating buttons.
them in hot soapy water first of all. Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Removing/inserting the metal grease filter: 1. Remove the wire frame. 2. Exchange the fleece filter. 3. Refit the wire frame.

cleaner. K Clean the surface in the same direction
as it has been ground and polished. K We recommend our stainless steel
cleaner no. 461731. See enclosed service booklet for order address.

Aluminium and plastic surfaces: K Do not use dry cloths. K Use a mild window cleaning agent. K Do not use aggressive, acidic or caustic
cleaners.
Activated carbon filter: For neutralising odours when hood is used in recirculating-air mode. The activated carbon filter is installed above the grease filter inside the extractor hood. Inserting/removing the filter: 1. Remove the filter frame (see details on previous page). 2. Place wing nut and sleeve over screw, insert into housing and tighten firmly (applies only when installing filter for first time).
Observe the warranty regulations in the enclosed service booklet. For appliances with a glass plate in the pull-out vapour extractor:
In so doing you will be ensuring that the extractor hood performs as effectively as possible.
K The glass plate is easily removed and
can be cleaned in a dishwasher. K To remove the lugs, push outwards.
Disposing of the old activated carbon filter: K Activated carbon filters do not contain
any pollutants and can be disposed of with domestic refuse.
Isolate the extractor hood by pulling out the mains plug or switching off the fuse. Do not clean the extractor hood with abrasive sponges or with cleaning agents which contain sand, soda, acid or chlorine! K Clean the extractor hood with a hot soap
– Screw, sleeve and wing nut are en-
closed with the activated carbon filter –. 3. Hook the activated carbon filter into the left-hand side of the extractor hood housing, push the other side upwards and secure in place with the wing nut.

solution or a mild window cleaner. K Do not scrape off dried-on dirt but wipe
off with a damp cloth. K When cleaning the grease filters, remove
grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. K Note: Do not use alcohol (spirit) on
plastic surfaces, as dull marks may appear. Caution: Ensure that the kitchen is ade- quately ventilated. Avoid naked flames!

Prior to installation
Important information
Old appliances are not worthless rubbish. Valuable raw materials can be reclaimed by recycling old appliances. Before disposing of your old appliance, render it unusable. You received your new appliance in a protective shipping carton. All packaging materials are environmentally friendly and recyclable. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner. Please ask your dealer or inquire at your local authority about current means of disposal. The extractor hood can be used in exhaust air or circulating air mode. Always mount the extractor hood over the centre of the hob. Minimum distance between electric hob and bottom edge of extractor hood: 430 mm, Fig. 1. The extractor hood must not be installed over a solid fuel cooker – a potential fire hazard (e.g. flying sparks) – unless the cooker features a closed, non-removable cover and all national regulations are observed. The smaller the gap between the extractor hood and hotplates, the greater the likelihood that droplets will form on the underside of the extractor hood.


100 120
100 120
The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. D Exhaust air must not be discharged via a smoke or exhaust gas flue which is already in use or via a shaft which is used for ventilating rooms in which fireplaces are located. Discharge exhaust air in accordance with official and statutory regulations (e.g. national building regulations). Discharge of air into smoke or exhaust air flues which are not in use requires the consent of a heating engineer. D If the extractor hood is operated in exhaust-air mode at the same time as a flue-type heater (e.g. gas, oil or solid-fuel heater, instantaneous water heater, boiler), ensure that there is an adequate air supply which the heater requires for combustion. Safe operation is possible provided that the partial vacuum in the room in which the heater is installed does not exceed 4 Pa (0.04 mbar).This can be achieved if the combustion air is able to flow through non- lockable openings, e.g. in doors, windows and in conjunction with an air supply/air- intake wall box or by other technical proce- dures such as reciprocal interlocking. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and gas cookers. The extractor hood can be used without restriction in circulating air mode – with an activated carbon filter. For exhaust air mode a one-way flap should be installed in the extractor hood unless already installed in the exhaust air pipe or wall box. If a one-way flap is not enclosed with the extractor hood, you purchase one from your dealer. If the exhaust air is conveyed through the outside wall, a telescopic wall box should be used.
For optimum extractor hood efficiency: K Short, smooth air exhaust pipe. K As few bends in the pipe as possible. K Diameter of pipe to be as large as pos-
sible (ideal is l 120 mm ) and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise. The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework. K Round pipes:
We recommend Internal diameter at least. 120 mm. K Flact ducts must have an internal
cross-section that equates to that of round pipes with a 100/120 mm internal diameter. There should be no sharp bends. l 100 mm approx. 078 cm2 l 120 mm approx. 113 cm2
Additional information concerning gas cookers: When installing gas hotplates, comply with the relevant national statutory regulations (e.g. in Germany: Technische Regeln Gasinstallation TRGI). Always comply with the currently valid regulations and installation instructions supplied by the gas appliance manufacturer. Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Gap at least 50 mm. Minimum distance on gas hotplates between the upper edge of the trivet and lower edge of the extractor hood: 650 mm, Fig. 1.
there is an adequate supply of fresh air.
twist it as far as it will go. K If the pipe diameter is 120 mm, cut out
the inner part of the outlet connector.
Exhaust-air mode

Preparing the wall cupboard
Installation inside the wall cupboard
ard, including a groove for the mains cable. – Template O I lis enclosed –.
template have been configured in such a way as to allow a 20 mm thick handle to be attached flush with the front edges of the cupboard. K If no handle is going to be attached, the
min.
mounting points must be brought forward by 20 mm. If the cupboard depth is greater than 280 mm, the hood can be mounted further back, . . . if the light strip under the cupboard . . . units is mounted further back, . . . if the handle is more than 20 mm thick.
Exhaust flows straight out at the back: – inside the wall cupboard –. K Cut a hole in the rear panel of the wall
cupboard, including a groove for the mains cable.
To do this, move the mounting points further towards the back by the corresponding distance.
Circulating-air mode K With activated carbon filter if exhaust-air
mode is not possible.
The complete installation set can be obtained from specialist outlets. The corresponding accessory numbers can be found at the end of these operating instructions.

ard, including a groove for the mains cable. – Template O I is enclosed –.
Ensure that there is a minimum gap between hob and extractor hood of 650 mm (for gas hobs) or 430 mm (for electric hobs). This extractor hood has been designed for installation inside a wall cupboard with the following dimensions: Width: 600 mm Depth: 280 bis 350 mm Height:at least 280 mm.
Preparation: 1. Remove bottom panel of cupboard – if fitted. The stability of the cupboard must be maintained.

Electrical connection
94 230 230 44 598
Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identify- ing marks on the plug terminals. This is what you have to do: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red.

mind.15
mind. 475

The extractor hood may only be connected to an earthed socket that has been installed according to the relevant regulations. If possible, site the earthed socket directly above the wall cupboard or in its immediate vicinity. K The earthed socket should be
If the shelf is permanently fixed inside the cupboard, 4 holes must be drilled to provide access to the 4 mounting screws for the extractor hood. 5. Route the mains cable through the hole in the wall cupboard and connect up the exhaust pipe. 6. Connect up the extractor hood to the mains. 7. If no handle is going to be attached to the vapour extractor, seal off the 3 holes with the enclosed caps.
connected via its own power circuit. K If the earthed socket is no longer
accessible following installation of the extractor hood, ensure that there is a permanently installed disconnector.
If it is necessary to wire the extractor hood directly into the mains: The extractor hood may only be connected up by a qualified electrician approved by the appropriate electricity company. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors.
extractor hood housing. – The board at the front should not be
attached to the housing. – Ensure that access is possible for

replacing filters or by Customer Service.
Electrical specifications: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1,30 m. This extractor hood complies with EC regulations relating to the suppression of RF interference.
Weight in kg:
Exhaust air Re-circulating air
The manufacturer reserves the right to make design alterations in the interests of technical development.
Attaching a handle to the vapour extractor: K A handle can be attached to the vapour
extractor. 1. Use the enclosed template O III to mark the 3 mounting points on the handle and start the hole with a gimlet. Details for drilling: l 2 mm – max. 10 mm deep.