The device you have just purchased was submitted to many tests and checks ensuring its quality. We thank you for your choice ant trust.We hope you will be fully satisfied.
These are located on the right-hand side of the appliance. The commercial code and the serial number identify for the manufacturer the particular panel hea- ter you have bought.
A Standards, quality labels
B Commercial name C Commercial code D Manufacturing reference E Serial number F Manufacturer’s number
Appliances with this symbol must not be scrapped with normal household rubbish but be collected separately and recycled. When these products come to the end of their useful life, they must be collected and recy- cled in accordance with the local regulations and bylaws.
Please keep this instruction manual even after installing your panel heater.
- Please ensure that children do not lean on the device or play close to it when it is operating : its
surface may be hot enough to cause burns to their skin in some circumstances, particularly becau- se their reflexes may not yet have been acquired or aur slower than those of an adult. If there is any risk, fit a protective grill in front of the device. - This device is not intended for use by persons (including children) with physical, sensory or mental
disability, or by persons lacking experience or knowledge, unless they have received from a person in charge of their safety adequate supervision or preliminary instructions on how to use the devi- ce. - Care must be taken at all times to keep children from playing with the device. - Do not obstruct the grills, even partially (either on the front of the device or underneath it): otherwi-
se the device may overheat. - If the supply cord is damaged, it must be replaced by a service agentor similarly qualified person in
order to avoid a hazard (applies to units fitted with a supply cord and plug). - Units fitted with a three core supply cord (brown, blue and black), must be directly connected to
hard wiring by a licensed electrician. - All work on the interior of the device must be carried out by a licensed electrician.

Installation guidelines - This device was designed to be installed in residential premises. In any other case, please call your
distributor. - Installation must comply with the standards currently enforced in the country of use. - The panel heater must be supplied with 230V single-phase 50Hz. - In damp areas such as bathrooms and kitchens, you must install the connection box at least 25cm
above the floor. Keep the panel heater away from any draughts that may interfere with its operation (e.g.: under a centrally controlled fan, etc...). Do not install the heater under a fixed socket. The panel heater is fitted with a detection system, whose sensor is located on the front of the appliance.
Volume 1 No electrical appliance
Volume 2 Class II IPX24 electrical appliance
Volume 3 Class II electrical appliance
Comply with the minimum distances from any furniture units when positioning the appliance.
To optimise absence detection by your appliance, do not install it in a closed off corner or behind furniture.
We strongly advise against installing vertical machines above an altitude of 1000m (risk of faulty operation).
Installing a machine at altitude causes an increase in air output temperature
(of the order of 10°C per 1000m above sea level).
It is forbidden to install a vertical machine horizontally or vice versa. Do not use the device in mobile, on feets or on casters.
50 cm · 15 cm

We recommend that you place the panel heater face down on the floor, taking care to protect its front surface from scratches.
1 2 While keeping the slid- er raised, push the hanging frame towards the bottom of the heater to release the upper brackets S2. We recommend that you wear protective gloves.
Take a flat-bladed screwdriver and lift the slider, taking care not to bend it.
3 4 Remove the hanging frame. Swivel the hanging frame downwards on the lower brackets S1.
FIXING THE HANGING FRAME TO THE WALL
1 2 Refit the hanging frame, lining up with drilling points A to find drilling points B (you can also use a level).
Place the hanging frame on the floor against the wall. Locate drilling points A.
Drilling points A show the position for the lower fastenings.
Drilling points B show the position for the upper fastenings.
3 4 Position the hanging frame and screw it down. Drill the 4 holes and insert the wall plugs. Use suitable wall plugs when fitting on a specific support (e.g. plasterboard wall).
Drilling points B · Drilling points A · Drilling points A

Connection rules and regulations - The panel heater must be supplied with 230V single-phase current at 50Hz. - The panel heater’s power supply must be directly connected to the main supply after the circuit brea-
ker without any intermediate switch. - The panel heater’s power cable must be connected to the main supply via a connection box. In damp
areas, such as bathrooms and kitchens, the connection box must be installed at least 25cm above the floor. - An Earth connection is prohibited. Do not connect the pilot wire (black wire) to Earth. - The installation must be fitted with an all-pole cut-off switch with a contact opening distance of at least
3mm. - If the power cable is damaged, it must only be replaced by an electrician. - If you are using the pilot wire and it is protected by a 30mA differential (e.g.: bathroom use), the pilot
wire’s power supply must also be protected on this differential.
Wiring diagram for the heating panel - Cut off the power supply and connect the wires as shown in the following diagram:

The pilot wire end is insulated and not further connected
- You can connect the pilot wire if your home is equipped with a programming unit or controller.
In this case, make the following checks according the selected mode (Comfort, Eco, etc.) to that the programming instructions are being transmitted correctly:


FRAME
1 2 Pivot the panel heater upwards and lift it to position it on brackets S2. Position the tilted panel heater on brackets S1.
S1
3 Lower the panel heater onto the hanging frame. A click tells you that the panel heater is fastened and locked in place.
To unlock the panel heater from the hanging frame, take a flat-bladed screwdriver and push the slider (located on the top left-hand corner of the hanging frame behind the appliance) towards the wall. Lift the panel heater while holding the slider in place with your screwdriv- er. Tilt it forwards and then remove it from brackets S1.



After 2 minutes of inactivity, the light on indicator D goes out automatically.


This mode enables you to have the ambient temperature you desire in your room. The consump- tion indicator lights enable you to optimise your setting (see page 33).

Set the temperature knob C to the desired temperature. For a setting of around 19°C, only the first light (green) on the indicator D comes on to indicate optimised consumption.
Set the cursor A to position The heating light E illuminates if the room’s temperature is below that indi- cated on the control knob C.
The heating light E illuminates if the room’s temperature is below that indicated on the control knob C.

Wait at least 6 hours for the room’s tem- perature to stabilise.
If the room’s temperature is not accept- able, progressively adjust the control knob C using the notches (one notch at a time).
If the room’s temperature is acceptable, setting is complete. The higher the temperature shown on the control knob C the more the indicator light D moves to the right.

ROOM: HOW TO USE ECO MODE
This involves a lowering of the temperature by around 3.5°C with respect to the Comfort tempe- rature , set on the control knob C. We recommend that you use this mode when you will be absent for 2 to 24 hours, or during the night, especially in bedrooms.
Set the cursor A to position The Comfort temperature will be lowered by about 3.5°C.
This mode enables you to lower the tem- perature automatically without altering the Comfort setting on the control knob C.

If you have a programmer:
HOW TO USE PROG MODE
Using the programming, you can adjust your panel heater’s settings to suit your lifestyle.
By connecting the pilot wire to a programmer, or if you use an on-board programmer (available as an option), you can programme your Comfort and temperature periods (please refer to the instructions included with your programmer). You can connect several appliances to one programmer.
The temperature set on the control knob C is the base temperature that will serve as a reference for the desired temperature according to the programming.
Order on your program-
COMFORT -1°C -1°C with respect to the setting on the knurled knob C
COMFORT -2°C -2°C with respect to the setting on the knurled knob C
ECO -3.5°C with respect to the setting on the knurled knob C
FROST Ambient temperature held at around 7°C.
STOP Immediate switch off of the heating (used to disconnect the power).
Set the Comfort temperature that will serve as a base for programming my reductions in temperature: Set the temperature control knob C to the desired temperature.
Set the cursor A to position
E
The heating light E illuminates if the room’s ambient temperature is below the desired temperature for the selected mode (Comfort temperature in Comfort mode and reduced temperature in Eco mode ).
NB : When there are no instructions from the pilot wire, the appliance heats in Comfort mode . The instructions for Frost and Stop take priority over Eco mode and Comfort mode . The changeover time is around 12 seconds when switching from Comfort mode to Eco mode
ming box Lower


To use these functions, we recommend that you set the cursor A to Comfort or Programming mode. These functions are in addition to the programming functions.
Do not heats the room while it is being ventilated allow you to save energy. If you do not turn off your heater when a window is open for a long time, the airing function stops your device from heating when it is not necessary: your heater automatically detects when the window is opened or closed and therefore saves energy. Your device reacts to an open or close window according to several variables, especially
- the temperature settings programmed for the room - the outside temperature - the location of your heater, etc.

By detecting whether the window is open or closed, the airing function helps you to be environmentally friendly: you save energy by not heating your house when you ventilated it.

To activate the airing detection function: Turn control knob B to position
The operating instructions are for 7°C ±3°C for the whole time that your room is being aired. When you close the window, your panel heater will return to its initial operating mode. After 2 hours, the appliance starts heating again in any case.The maximum expected airing period is 2 hours.
NB: If the function does not meet your requirements, you can manually stop the panel heater from heating (Stand-by mode ). When the function is running, the green LED flashes slowly.


The absence detection function enables you to lower the temperature setting for your room automatically, as soon as you leave it.
To activate the absence detection function: Turn control knob B to position
If your panel heater detects no one in the room, it automatically lowers the temperature setting progressively to 3.5°C lower than the Comfort temperature setting.
The programming instructions ( ) take priority over absence detection.
To activate the airing + absence detec- tion function: Turn control knob B to position
To deactivate the energy-saving func- tions: Turn control knob B to position
To optimise your setting: - Activate the energy-saving functions (knob B), - Adopt “19°C” as a standard (1° less = 7% savings in energy).

All the panel heaters in the same room must be fitted with the same function capabilities.The energy-saving functions must be set in the same way on each heater.
We do not recommend the use of the “airing” and “airing + absence detection” functions in corridors and rooms located close to an entrance door from outside your home or from the garage.

Absence detection is made from a height of over 45cm (Diagram 1) and operates progressively (Diagram 2):
E.g.:Your appliance is set to 19°C, in Comfort mode (whether programmed or not)
At 9:00, it detects your absence. At 9: 30, its operating instructions are set to18°C. At 10:00, its operating instructions switch to 17°C. At 10:30, its operating instructions switch to 15.5°C.
The energy consumed by an electrical heating appliance depends, among other things, on the temperature required. The temperature recommended by the public authorities is 19°C, in Comfort mode (15.5°C in Eco mode).
The “Consumption Indicator” function enables you to position yourself in accordance with this recommended temperature.
Therefore, depending on the temperature required:
- If the second orange or red LED is lit, you can behave more responsibly by lowering your required temperature significantly. - If the first orange LED is lit, you can behave more responsibly by lowering your requi- red temperature slightly. - If the green LED is lit, you are at the recommended temperature and are already behaving responsibly.

It is pointless to set your panel heater to the maximum setting; your room’s temperature will not rise any faster. All the appliances in the same room must be set in the same way.
Set the cursor A to
PROG
bles you to ensure an automatic reduc- tion in temperature during your absen- ce (see the section “How to use the energy-saving functions”).
Your panel heater will maintain a tempera- ture approximately 3.5°C lower than the Comfort temperature you have set.


Your panel heater will maintain a tempera- ture of 7°C ±3°C, corresponding to the Frost setting.
Release the panel heater from its hanging frame (see Page 26).

Set the control knob C to the desired position.
Remove one pin from its holder on the back of the control box.
Place the locking pin in the hole opposite the arrow.
Now the setting on the con- trol knob C cannot be altered.



Set the control knob C to the maximum tempera- ture desired.
Remove one pin from its holder on the back of the control box.
In the example above, the maxi- mum temperature is 21°C.


3 Set the control knob C to the minimum temperature desired.
Place the locking pin in the hole to the left of the arrow.
In the example above, the mini- mum temperature is 19°C.

Remove one pin from its holder on the back of the control box.
Place the locking pin in the hole to the right of the arrow.
In our example, the control knob C cannot go below 19°C or rise above 21°C.


Set the control knob B to the desired position.
Remove one pin from its holder on the back of the control box.
Place the locking pin in the hole opposite the arrow.
Now the setting on the con- trol knob B cannot be altered.
Lock the panel heater onto its hanging frame (see Page 24).
To maintain your panel heater’s performance, you must dust it approximately twice a year. Never use abrasive products or solvents.

C HECKS TO BE MADE
ENCOUNTERED
The panel heater does not heat.
- Check that the cursor is on position . - If you are operating under programming, check that the programmer is in
COMFORT mode. - Ensure that the installation’s circuit breakers are engaged and that the power
cut-off (if you have one) has not cut off the power to the panel heater. - Check the air temperature in the room: if it is too high, the heating light E
does not illuminate: the panel heater does not heat. - Check that the control knob B is not in Airing position and that there are no draughts.
The panel heater heats all the time.
- Check that the panel heater is not in a draught or that the temperature set-
ting ha not been altered. - There may be a fluctuation in the main power supply. If there is a problem
(blocked thermostat...), cut off the power to the panel heater (fuse, circuit breaker) for approximately 10 minutes and then switch it back on. - If the phenomenon recurs frequently, have your electricity utility check the
power supply.
The panel heater’s surface is very hot.
It is normal for the panel heater to be hot when it is operating; the maximum surface temperature is restricted in accordance with the NF electrical per- for-mance standard. However, if you think that your panel heater is still too hot, check that the output is suitable for the area of your room (we recom- mend 100W / m2) and that the heater is not placed in a draught, which would interfere with its self-regulation; also check that the installation guidelines have been followed (curtains, etc.)
The panel heater does not follow its programming instructions.
Ensure that the energy controller or programming unit is being used correct- ly (see the user’s manual).
The heating light E flashes rapidly (lit 0.5 seconds, unlit 0.5 seconds).
The measurement sensor has deteriorated. Contact your installer.
The consumption indicator light D flas- hes rapidly (lit 0.5 seconds, unlit 0.5 seconds).
Your panel heater’s absence detector is disconnected or is not working. Contact your installer. The functions other than absence detection still remain operational.

C HECKS TO BE MADE
ENCOUNTERED
The heating light E flashes slowly (lit 1 second, unlit 1 second).
Your panel heater’s potentiometer has deteriorated. Contact your installer.
The airing detector does not react
Your panel heater’s environment may interfere with this function’s ability to react (e.g.: distance of the panel heater from the window, the external tem- perature, the room’s level of insulation, etc.). During airing, switch the cur- sor A to Stand-by mode .
- The ambient tem-
If your ambient temperature, after 6 hours without adjusting the mode or the setting, still differs from that set on the control knob, you can recalibra- te your panel heater.
perature is diffe- rent from the tem- perature set on the control knob C.
If a pilot wire kit or a carrier current interface is fixed to the back of your panel heater, it is best to remove this first.
- Control knob C is
For recalibrating the heater, the temperature on the control knob C must be set between 18°C and 23°C.
set to 19°C, a light other than the green one is lit.
- While holding knob C, unlock the locking pin behind the knob with a flat- bladed screwdriver.
- Turn the knob’s numbered part C1 while hol- ding the upper part C2 to match up the room’s temperature with that shown on the knob. Take care not to turn the upper part C2: this would disrupt the panel heater’s controls.
- Relock the pin by pressing it down.
If you do not succeed in solving your problem, contact your local installer and have the details of your heater’s references,the room’s temperature and the programming system (if any) to hand.

Any intentional damage (perforation, scratches) to the absence detector’s lens rescinds your appliance’s war- ranty.
Hold · Turn

- The guarantee period is two years from the date of installation or purchase and may not exceed
30 months from the date of manufacture in the absence of a receipt. -The guarantee covers the replacement and supply of components recognised as being defective,
excluding any damages or interest. - The user is responsible for any labour or transport costs. - The guarantee does not cover any damage arising from improper installation, abnormal use or
non-observance of the requirements of the said instructions for installation and use . - The stipulations of the present guarantee conditions do not exclude any of the purchaser’s legal
rights of guarantee against faults or hidden defects, which are applicable in all cases under the sti- pulations of Articles 1641 of the Civil Code. - Present this certificate to your distributor or installer only in the event of a claim, together with
your purchase invoice.
TYPE OF DEVICE*: SERIAL NUMBER*: CUSTOMER’S NAME AND ADDRESS:
* This information can be found on the information plate situated on the left-hand side of the device. ATLANTIC INTERNATIONAL Tel: (33) 146836000 Fax: (33) 146836001
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The panel heater does not heat. | - Check that the cursor is on position . - If you are operating under programming, check that the programmer is in COMFORT mode. - Ensure that the installation’s circuit breakers are engaged and that the power cut-off (if you have one) has not cut off the power to the panel heater. - Check the air temperature in the room: if it is too high, the heating light E does not illuminate: the panel heater does not heat. - Check that the control knob B is not in Airing position and that there are no draughts. | p.17 | |
| The panel heater heats all the time. | - Check that the panel heater is not in a draught or that the temperature set- ting ha not been altered. - There may be a fluctuation in the main power supply. If there is a problem (blocked thermostat...), cut off the power to the panel heater (fuse, circuit breaker) for approximately 10 minutes and then switch it back on. - If the phenomenon recurs frequently, have your electricity utility check the power supply. | p.17 | |
| The panel heater’s surface is very hot. | It is normal for the panel heater to be hot when it is operating; the maximum surface temperature is restricted in accordance with the NF electrical per- for-mance standard. However, if you think that your panel heater is still too hot, check that the output is suitable for the area of your room (we recom- mend 100W / m2) and that the heater is not placed in a draught, which would interfere with its self-regulation; also check that the installation guidelines have been followed (curtains, etc.) | p.17 | |
| The panel heater does not follow its programming instructions. | Ensure that the energy controller or programming unit is being used correct- ly (see the user’s manual). | p.17 | |
| The heating light E flashes rapidly (lit 0.5 seconds, unlit 0.5 seconds). | The measurement sensor has deteriorated. Contact your installer. | p.17 | |
| The consumption indicator light D flas- hes rapidly (lit 0.5 seconds, unlit 0.5 seconds). | Your panel heater’s absence detector is disconnected or is not working. Contact your installer. The functions other than absence detection still remain operational. | p.17 | |
| The heating light E flashes slowly (lit 1 second, unlit 1 second). | Your panel heater’s potentiometer has deteriorated. Contact your installer. | p.18 | |
| The airing detector does not react | Your panel heater’s environment may interfere with this functi react (e.g.: distance of the panel heater from the window, the perature, the room’s level of insulation, etc.). During airing, s sor A to Stand-by mode . | p.18 | |
| - The ambient tem- perature is diffe- rent from the tem- perature set on the control knob C. - Control knob C is set to 19°C, a light other than the green one is lit. | If your ambient temperature, after 6 hours without adjusting the setting, still differs from that set on the control knob, you te your panel heater. If a pilot wire kit or a carrier current interface is fixed to the back of your panel heater, it is best to remove this first. For recalibrating the heater, the temperature on the control knob C must be set between 18°C and 23°C. - While holding knob C, unlock the locking pin behind the kn bladed screwdriver. C2 Ho - Turn the knob’s numbered part C1 while hol- Tu ding the upper part C2 to match up the room’s temperature with that shown on the knob. Take care not to turn the upper part C2: this would panel heater’s controls. - Relock the pin by pressing it down. | p.18 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.