OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage. Store these instructions in a safe place for future reference.





Min/max operating limits (internal temperature) Cooling: 16 °C DB / 35 °C DB Dehumidification: 16 °C DB / 35 °C DB Cooling mode room temperature adjustment range: 16 °C DB / 30 °C DB
(13)

APPLIANCE START-UP Open the packaging and remove the box from above. Remove the product and the other elements supplied (illustrated in the box below).
Type AAA batteries for the remote control


Round fitting for window (1) to be positioned between the end of the tube and the end fitting for the window
End fitting for window (2)
Flat fitting for positioning between the air discharge outlet and the

Clamp Cap Cord winder Drain hose
Round fitting for window unit, to be positioned between the end of the tube and the window unit
Window unit kit (3 pcs)




Position the product vertically on a flat and stable surface, as close as possible to a window and at least 50 cm from walls or other nearby obstacles.

Install the cord winder hooks to the back of the unit using the screws, as shown in the figure.
When the appliance is not being used, wind the power cord around the hooks.


The hooks must be positioned facing upwards anddownwards.
Wind the cord around the hook.
Connect the flat fitting to the hose, extend the hose as far as necessary for reaching the outside and it connect to the back of the air conditioner.
Next, slide the flat fitting downwards into the grooves (A) and secure it with the hook (B). The upward-facing side of the flat fitting is marked "TOP".


Connect the round window fitting (1) to the end of the hose then the end fitting for the window (2).
Open the windows and lock one of the two leaves with the handle. Place the end fitting against the fixed leaf of the window, and draw the other leaf towards it.



Make a hole measuring roughly 135 mm through the window pane.
Insert the window unit without its closure cap into the window. Insert the round fitting into the retractable hose and insert the retractable hose with the round fitting into the window unit.


Insert the assembled hose into the back of the air conditioner.
Insert the flat fitting onto the hose.


The outlet must be between 40 cm and 130 cm above the ground.
Avoid tight curves or bends in the flexible hose.


When the air conditioner is not being used, disconnect the hose and fit the closing cap.

Connect the power cord to a suitable electrical socket (230 V). Insert the batteries supplied into the remote control, while observing the polarities. Select the desired operating mode from the remote control.

This appliance can be used for cooling, dehumidifying and ventilating. When switching between modes, the fan continues to rotate but the compressor stops: the compressor will start after 3 minutes. This delay protects the compressor from potential damage.


THE DISCHARGE TUBE MUST ALWAYS BE CONNECTED to the appliance: the only exception is when the appliance is used solely for dehumidification, in which case it is advisable to let the appliance discharge directly into the environment for maximum efficiency (consult the "Dehumidification Mode" paragraph). Regularly clean the air filters beneath the easily removable rear grille to keep the air conditioner working efficiently.
Cooling, Ventilation · Dehumidification

This appliance automatically vaporises condensate in the cooling mode. When the air conditioner operates in cooling mode, there is no need to drain condensate continuously; only in certain weather conditions with very humid air may it occur that water deposits inside the unit. When its inner tank is full, the air conditioner beeps 8 times and the message "H8" appears on the display to signal that the tank is full and stop the appliance's operation. INSTALLATION OF THE DRAINAGE HOSE 1. Remove the rubber plug at the back of the unit (1).



Cooling When the unit operates in the cooling mode, ensure that the rubber cap closing the drainage opening on the back of the appliance is properly positioned. To empty the container, switch the air conditioner off and unplug the cord. Remove the cap from the rear drainage opening and place its end over a normal drain. Ensure that the tube is not twisted or bent. The tube must slope downwards. Re-close the drainage opening with the cap, insert it into the clamp and resume use of the air conditioner.




Dehumidification WARNING! When using the air conditioner in dehumidification mode, we recommend always ensuring continuous drainage, in order to maximise dehumidification efficiency. Use the drainage outlet on the appliance. The water can be drained into a drain by simply connecting a tube with 14 mm internal diameter (not supplied).


REMOTE CONTROL OPERATION Insert the batteries into the remote control, while respecting the indicated polarities. Only use type AAA 1.5V batteries. Remove the batteries if the remote control is not used for a month or longer. Do not attempt to recharge the batteries. Replace all batteries at the same time. Do not throw the batteries into fire: they may explode.

INFORMATION FOR CORRECT DISPOSAL OF THE BATTERIES PURSUANT TO EUROPEAN DIRECTIVE 2006/66/EC Replace the batteries when depleted. At the end of their working life, batteries must be disposed of separately from unsorted waste. They must be must be delivered to appropriate separated waste disposal plants or to dealers that provide a similar service. Separate waste disposal of batteries prevents potential negative effects on the environment and human health resulting from inadequate disposal, and also allows the materials from which it is made to be recovered and recycled in order to achieve significant savings in terms of energy and resources. The separate disposal obligation is underlined by the crossed-out dustbin symbol appearing on the battery. Illegal disposal of the product by the user is subject to administrative penalties as per current regulations.
FOR OPTIMAL REMOTE CONTROL OPERATION, POINT THE TRANSMITTER HEAD TOWARDS THE RECEIVER LOCATED ON THE AIR CONDITIONER. The remote control can be activated by pressing the ON/OFF button on the portable unit. The icon on the remote control display will flash once and a buzzer will sound to indicate that the signal was transmitted to the air conditioner. In the OFF mode, the set temperature and set timer will appear on the remote control.



a. Cooling b. Dehumidification c. Ventilation d. Temperature setting e. Timer setting f. Speed setting g. Lock h. Sleep mode setting i. X-FAN mode setting l. Signal transmission m. T-OFF off timer n. T-ON on timer

(1)ON/OFFBUTTON Press this button to switch the unit on or off. When switched on, the appliance will start functioning based on its last settings (save function). (2)MODE SELECTION BUTTON (MODE) Press this button to select the various operating modes, according to the following sequence: Cooling (Cool) → Dehumidification (Dry) → Ventilation (Fan Only)
In the COOL mode the display lights up. In the DRY and FAN modes the display does not light up.
Signal receiver · Operating display

(3) TEMPERATURE + - AND TIMER ADJUSTMENT BUTTONS The temperature can be adjusted to between 16 °C and 30 °C. Increase temperature(+): 1) Allows for adjusting the desired temperature in cooling (COOL) mode. 2)Whenever the(+) button is pressed, the set temperature increases by 1 °C.
Decrease temperature (- ): 1) Allows for adjusting the desired temperature in cooling (COOL) mode. 2)Whenever the ( - ) button is pressed, the set temperature decreases by 1 °C. The same button allows for setting the TIMER. (4) FAN SPEED ADJUSTMENT BUTTON Press this button when the appliance is switched on for adjusting the ventilation speed in cooling mode (AUTO), to low (Low), medium (Med) or high (High).
The fan speed cannot be adjusted in DRY mode and is fixed to low speed. (5)SLEEP BUTTON (on both the remote control and portable unit)
Press this button to activate the Sleep function, which automatically adapts the temperature to changes in body and
room temperature throughout the night, so as to optimise comfort when sleeping and minimise consumption. In cooling mode, the temperature increases by 1 °C in an hour then by 2 °C in two hours, and remains in this setting for
the whole period. The Sleep function is not available in the ventilation, dehumidification and auto modes. The indicator light turns on whenever the Sleep function is set. (6)TIMER BUTTON (on both the remote control and portable unit)
Press and hold this button for 1 second to set the timer.
1)Timer-on (automatic switch-on) When the appliance is off, this button is used to set a delay after which the unit will switch on. Remote control: Press TIMER. The T-ON and H icons will light up on the remote control. Press the + and - buttons within 5 seconds to set the delay. The T-ON icon will remain on to indicate that the TIMER has been set. Portable unit: Press TIMER. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm.
2)Timer-off (automatic switch-off) When the appliance is running in the COOL mode, set a delay after which the unit will switch off. Remote control: Press TIMER. The T-OFF and H icons will light up. Press the + and - buttons within 5 seconds to set the delay. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm. The T-OFF icon will remain lit to indicate that the switch-off TIMER is running. Portable unit: Press TIMER. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm. Resetting the timer: If a TIMER has been set, press TIMER to display the delay. Press TIMER again to cancel the setting. (7) X-FAN BUTTON (only on remote control)
By pressing the X-FAN button in the cooling and dehumidification modes, when the unit is switched off the fan continues to turn for roughly 2 minutes in order to fully dry the evaporator. (8) TEMPERATURE AND ERROR DISPLAY

F4 The external temperature sensor has short-circuited.
Contact the service centre.
The temperature and error display lights up only in the COOL mode. In the DRY and FAN modes the display does not light up.
SAFETY FUNCTIONS REMOTE CONTROL LOCK Simultaneously press "+" and "-" to lock the remote control. The "Lock" icon will light up on the remote control, and the latter will not respond to commands. SWITCHING BETWEEN °C AND °F. Press the "-" and "MODE" buttons simultaneously to switch between °C and °F.
CARE AND MAINTENANCE WARNING! Prior to carrying out any cleaning or maintenance, unplug the unit from the power socket. 1. Cleaning the air filters The air filter must be checked at least once every two weeks of operation. Operating with dirty or clogged filters will decrease the effectiveness of the air conditioner and can cause serious problems. To remove the filter, release the rear grille then slide out the filter by gently pulling it sideways. Use a vacuum cleaner to remove any dust. Should this not be sufficient, wash the filter with lukewarm water and neutral detergent (if necessary), rinse it with cold water then leave it to dry naturally before putting it back in place. After putting the filter back in place, close the grille and resume use of the air conditioner.



2. Cleaning the casing. Use a soft damp cloth to clean the outer surface of the air conditioner. Do not use excessively hot water, solvents, petrol or other aggressive chemical compounds, talcum powder and brushes: they may damage the surface or colour of the casing. Remove any stains using warm water with a little neutral detergent. Do not pour water onto the air conditioner to clean it: this may damage the internal components or cause a short circuit. 3. Storage. When you do not envisage using the air conditioner for a long time, clean the filters before storing it away. Keep the appliance in a vertical position at all times. Do not place any heavy objects on the top and, if possible, protect the air conditioner with a plastic sheet. 4. Transport. Preferably keep the air conditioner in the vertical position when transporting it. Should this not be possible, rest it on its right-hand side; when it reaches its destination, immediately put the appliance in the vertical position and wait at least 4 hours before using it in the cooling mode. 5. For complete safety, regularly check the condition of the power cord; should it be damaged through use, contact the Service Centre to replace it.


INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2012/19/EU This appliance may not be scrapped with domestic waste at the end of its life cycle. We call your attention to the crucial role played by the consumer in the re-use, recycling and other forms of recovery of such waste. The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer (no charge is levied for this service), when you purchase a new equivalent appliance. Sorted disposal of electric and electronic equipment prevents the negative effects on the environment and human health resulting from improper scrapping, and also allows the materials from which it is made to be recovered and recycled, with significant savings in terms of energy and resources. The sorted disposal requirement is indicated by the crossed waste bin label affixed to the appliance.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| E5 | Overcurrent protection device. | Pull out the plug and insert it again after 10 minutes. If the problem persists, contact a service centre. | p.11 |
| H8 | Tank full of water. | Empty the tank. If the problem persists, contact a service centre. | p.11 |
| F1 | Room temperature sensor failure. | Contact a service centre. | p.11 |
| F2 | Failure of temperature sensor on the evaporator. | Contact a service centre. | p.11 |
| F0 | Refrigerant leakage. Air conditioner out of order. | Contact a service centre. | p.11 |
| H3 | Overload protection device on compressor. | The room temperature exceeds the appliance's operating range (beyond 35°) or there is too much humidity. Wait for the temperature to drop below 35 °C. Check if the evaporator and compressor are obstructed by objects. If they are, remove the objects, disconnect the unit then restore the power supply. Clear the obstructed ventilation grilles. If the problem persists, contact a service centre. | p.11 |
| E8 | Overload protection. | p.11 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.