EN
ARGO logo
Official user manual

Argo Relax

12 pages·3.3 MB·Air Conditioner·PDF·ENDEFRITNLJA
Argo Relax
Table of Contents 13 sections PORTABLE AIR CONDITIONER (LOCAL) · EN · DESCRIPTION OF THE APPLIANCE FRONT VIEW · REAR VIEW · … ShowHide
Page 1 of the Argo Relax user manual — EN
Page 1 · click to enlarge
Page 1
Argo Relax — PORTABLE AIR CONDITIONER (LOCAL) diagram (page 1)
Fig. 1

PORTABLE AIR CONDITIONER (LOCAL)

EN

Argo Relax — EN diagram (page 1)
Fig. 2
Argo Relax — EN diagram (page 1)
Fig. 3
Argo Relax — EN diagram (page 1)
Fig. 4
Argo Relax — EN diagram (page 1)
Fig. 5
Argo Relax — EN diagram (page 1)
Fig. 6
Argo Relax — EN diagram (page 1)
Fig. 7
Argo Relax — EN diagram (page 1)
Fig. 8
Argo Relax — EN diagram (page 1)
Fig. 9
Argo Relax — EN diagram (page 1)
Fig. 10
Argo Relax — EN diagram (page 1)
Fig. 11
Argo Relax — EN diagram (page 1)
Fig. 12
Argo Relax — EN diagram (page 1)
Fig. 13
Argo Relax — EN diagram (page 1)
Fig. 14
Argo Relax — EN diagram (page 1)
Fig. 15

OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance work. Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage. Keep these instructions in a safe place for future reference.

Page 2 of the Argo Relax user manual — PORTABLE AIR CONDITIONER (LOCAL)
Page 2 · click to enlarge
Page 2
  • GENERAL OPERATING AND SAFETY INSTRUCTIONS
  • This appliance is a portable air conditioner, designed for domestic use.
  • Only use this air conditioner as described in this manual.
  • Ensure that the required voltage and frequency (220-240V/50Hz) match the available power source.
  • Ensure that the electricity system is able to deliver the operating current needed by the air conditioner in addition to that normally absorbed by other appliances (electrical appliances, lighting, etc.). Please refer to the maximum absorption data given on the air conditioner data plate.
  • Connection to the electricity grid must take place in accordance with current installation standards.
  • Ensure that the automatic switches and system protection valves are able to withstand a start-up current of 7A (normally for less than 1 second).
  • The system socket must always be fitted with an efficient earth.
  • Make sure the plug is inserted fully. Do not use multiple adapters. Do not touch the plug with wet hands. Make sure the plug is clean.
  • Do not use the plug as a means by which to start/stop the air conditioner: use the ON/OFF button on the remote control or on the control panel.
  • Do not install the air conditioner in rooms that may be subject to water spray (e.g. laundries).
  • This dehumidifier can be used by children of 8 years of age an upwards, and by persons with reduced physical, sensorial and mental capacity, or who are not familiar with its operation, under the supervision or instruction of a person responsible for their safety, so that they are fully aware of the attendant risks.
  • Do not allow the unit to be cleaned or serviced by unsupervised children.
  • Before moving or cleaning, ensure that the device is unplugged from the socket.
  • Do not move the air conditioner while it is operating; first turn the appliance off, check and remove any condensation that may have formed.
  • To turn the appliance off, set the remote control to OFF and remove the plug from the socket. Only pull on the plug. Do not pull the cord.
  • Do not use the appliance if the cord or plug are damaged. If the power supply cord is damaged, it must be replaced by the manufacturer, dealer or a similarly qualified person so as to avoid any safety risks. PRECAUTION!
  • Do not insert any objects into the air conditioner: this is very dangerous as the fan turns very quickly.
  • Ensure that air circulates freely around the unit. Do not cover the air intake and delivery grilles with drapes or in any way. WARNING!
  • The air conditioner must be positioned at least 50 cm from the wall and any other obstacles, on a firm, flat surface to avoid water leaks.
  • The air conditioner is fitted with a system to protect the compressor from overload. This means that the compressor only starts once 3 minutes have passed from its previous stop.
  • Please wait at least 3 minutes before starting the unit. This helps prevent the compressor from being damaged. WARNING! In the event of an anomaly, switch the appliance off and unplug from the socket. Do not dismantle or attempt to repair or modify the product. In the event of a malfunction, contact the after-sales service centre directly. WARNING!
  • Do not expose the air conditioner to direct sunlight, as the colour of the materials may change and if the appliance overheats, this may activate the protection mechanism, causing it to switch off.
  • Do not use insecticides, oils, detergents or spray paints near the appliance; do not use aggressive chemical detergents to clean the casing: this may damage the finish and colour.
  • Close all open windows to maximise air-conditioning efficiency. The manufacturer will not be held liable if safety and accident prevention rules are not observed.
Page 3 of the Argo Relax user manual — REAR VIEW
Page 3 · click to enlarge
Page 3

DESCRIPTION OF THE APPLIANCE FRONT VIEW

Argo Relax — DESCRIPTION OF THE APPLIANCE FRONT VIEW diagram (page 3)
Fig. 16
1. CONTROL PANEL - FUNCTION BUTTONS WITHOUT REMOTE CONTROL 2) HANDLE 3) REMOTE CONTROL COMPARTMENT DOOR 4) AIR DELIVERY 5) HORIZONTAL LOUVERS 6) VERTICAL LOUVERS 7) WHEELS 8) AIR INTAKE 9) GRILLE 10) TERMINAL CONNECTION FOR WINDOW 11) CIRCULAR CONNECTION FOR WINDOW 12) AIR EXPULSION HOSE 13) AIR EXPULSION HOSE TERMINAL CONNECTION 14) FLAT CONNECTION 15) POWER CORD 16) CORD STORAGE HOOKS 17) REMOTE CONTROL 9) A 1

REAR VIEW

Min/max operating limits (internal temperature) Cooling: 18°C B.S. / 35°C B.S. Dehumidification: 10°C B.S. / 35°C B.S. Cooling mode room temperature adjustment range: 16°C B.S. / 30°C B.S.

Argo Relax — REAR VIEW diagram (page 3)
Fig. 17
Argo Relax — REAR VIEW diagram (page 3)
Fig. 18

(17)

Page 4 of the Argo Relax user manual — DESCRIPTION OF THE APPLIANCE FRONT VIEW
Page 4 · click to enlarge
Page 4

APPLIANCE START-UP Open the packaging and remove the box from above. Remove the product and the other elements supplied (illustrated in the box below).

Type AAA batteries for the remote control.

Argo Relax — DESCRIPTION OF THE APPLIANCE FRONT VIEW diagram (page 4)
Fig. 19
Argo Relax — DESCRIPTION OF THE APPLIANCE FRONT VIEW diagram (page 4)
Fig. 20

Circular connection for window (1) for positioning between the end of the tube and the terminal connection for the window.

Terminal connection for window (2).

Flat connection for positioning between the air discharge port and the hose

Hose.

Screws.

Argo Relax — DESCRIPTION OF THE APPLIANCE FRONT VIEW diagram (page 4)
Fig. 21

Clamp Cap Cord storage Drain hose

Circular connection for window unit, for positioning between the end of the tube and the window unit itself.

Window unit kit (3 pcs)

Argo Relax — DESCRIPTION OF THE APPLIANCE FRONT VIEW diagram (page 4)
Fig. 22

Window unit.

Cap.

Argo Relax — DESCRIPTION OF THE APPLIANCE FRONT VIEW diagram (page 4)
Fig. 23
Argo Relax — DESCRIPTION OF THE APPLIANCE FRONT VIEW diagram (page 4)
Fig. 24
Argo Relax — DESCRIPTION OF THE APPLIANCE FRONT VIEW diagram (page 4)
Fig. 25

Place the product in a vertical position on a flat, stable surface, as close as possible to a window; leave a clearance of 50 cm from walls and other objects. INSTALLING THE CORD STORAGE HOOKS

Install the cord storage hooks to the back of the unit using the screws, as shown in the figure.

When not using the appliance, wind the power cord onto these hooks.

Argo Relax — DESCRIPTION OF THE APPLIANCE FRONT VIEW diagram (page 4)
Fig. 26
Argo Relax — DESCRIPTION OF THE APPLIANCE FRONT VIEW diagram (page 4)
Fig. 27

LCD remote control

Page 5 of the Argo Relax user manual — USE WITH WINDOW UNIT KIT
Page 5 · click to enlarge
Page 5

USE WITH TERMINAL CONNECTION FOR WINDOW

Connect the flat connection to the hose, extend the hose as far as necessary to reach the outside and connect it to the back of the air conditioner.

Now slide the flat connector downwards into the grooves (A) and secure it with the hook (B). The upper side of the flat connector is marked TOP.

Argo Relax — USE WITH TERMINAL CONNECTION FOR WINDOW diagram (page 5)
Fig. 28
Argo Relax — USE WITH TERMINAL CONNECTION FOR WINDOW diagram (page 5)
Fig. 29

Connect the circular window connector (1) to the end of the hose and then the window terminal (2).

Open the windows and block one of the two leafs with the handle. Rest the terminal connector against the fixed section of the window,and move the other section up towards it.

Argo Relax — USE WITH TERMINAL CONNECTION FOR WINDOW diagram (page 5)
Fig. 30
Argo Relax — USE WITH TERMINAL CONNECTION FOR WINDOW diagram (page 5)
Fig. 31

USE WITH WINDOW UNIT KIT

Make a 135 mm hole in the window panel.

Insert the window unit without its closure cap into the window. Fit the circular connector into the retractable hose and insert the hose with its circular connector into the window unit.

Argo Relax — USE WITH WINDOW UNIT KIT diagram (page 5)
Fig. 32
Argo Relax — USE WITH WINDOW UNIT KIT diagram (page 5)
Fig. 33

Insert the assembled hose into the back of the air conditioner.

Fit the flat connector to the hose.

Argo Relax — USE WITH WINDOW UNIT KIT diagram (page 5)
Fig. 34
Argo Relax — USE WITH WINDOW UNIT KIT diagram (page 5)
Fig. 35
Page 6 of the Argo Relax user manual — HOW TO USE THE APPLIANCE
Page 6 · click to enlarge
Page 6

The outlet must be between 40 cm and 100 cm off the ground. Avoid tight curves and folds in the hose.

Argo Relax — HOW TO USE THE APPLIANCE diagram (page 6)
Fig. 36
Argo Relax — HOW TO USE THE APPLIANCE diagram (page 6)
Fig. 37

When not using the air conditioner, disconnect the hose and fit the closing cap.

Argo Relax — HOW TO USE THE APPLIANCE diagram (page 6)
Fig. 38

Connect the power cord to a suitable electrical socket (230V). Insert the provided batteries into the remote control, making sure to observe their indicated polarities. Select the desired operating mode from the remote control.

HOW TO USE THE APPLIANCE

This appliance can be used to Cool, Dehumidify and Fan. When switching between modes, the fan continues operating but the compressor stops: the compressor will start again 3 minutes later. This delay protects the compressor from potential damage.

Argo Relax — HOW TO USE THE APPLIANCE diagram (page 6)
Fig. 39
Argo Relax — HOW TO USE THE APPLIANCE diagram (page 6)
Fig. 40

THE DISCHARGE TUBE MUST BE CONNECTED to the appliance AT ALL TIMES: the only exception is when the appliance is used for Dehumidification only, in which case it is recommended that the appliance discharges directly into the environment to obtain maximum efficiency (see the paragraph entitled "Dehumidification Mode"). Clean the air filters under the easily removable rear grille regularly to keep the air conditioner working efficiently.

Cool, Fan · Dry

Page 7 of the Argo Relax user manual — HOW TO ELIMINATE CONDENSATION
Page 7 · click to enlarge
Page 7

OPERATING MODES

1. COOL MODE

  • The first time it is turned on, the air conditioner will operate in Cooling mode with the temperature set to 25ºC by default.
  • The control panel Cool led will turn on.
  • The temperature can be adjusted from 16° to 30°C.
  • In this mode, each time the ON/OFF button is pressed, the unit switches off, the appliance saves the temperature setting and, when switched back on again, it will retain this setting.
  • In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set.
  • For more silent operation, run the fan at low speed 2. DRY MODE
  • Press the MODE button to select Dry.
  • The temperature is controlled by the electronic card and cannot be regulated.
  • In this mode, each time the ON/OFF button is pressed, the unit switches off, the appliance saves the settings and when switched back on again, it will retain them.
  • Fan speed is fixed to low and cannot be adjusted. NOTE The air conditioner does not cool the environment when operating as a dehumidifier. When the appliance is used as a dehumidifier, the flexible hose must not be connected. For maximum dehumidification efficiency, leave the rear discharge attachment free to discharge directly into the environment. Dehumidification mode is recommended in autumn and winter. If used in the summer, it is best to leave the flexible hose attached, in order to send the hot air outside rather than releasing it into the environment. During dehumidification, it is best to provide for continuous drainage (see the next chapter, "HOW TO ELIMINATE CONDENSATION"). 3. FAN ONLY MODE
  • Press the MODE button until the Fan icon displays.
  • In this mode, the fan speed can be set.
  • The temperature cannot be regulated.

HOW TO ELIMINATE CONDENSATION

This equipment automatically evaporates condensation in Cooling and Heating mode. When the air conditioner operates on Cool mode, there is no need to arrange for continuous drainage of condensation; only in specific weather conditions where air humidity levels are very high may water deposit within the unit. When the unit's tank is full, it beeps 8 times and the display reads “H8” to indicate that the tank is full; the air conditioner switches off. INSTALLING THE DRAIN HOSE 1. Remove the rubber plug on the back of the unit.

2. Screw the clamp onto the back of the unit to the right of the drain hole.
Argo Relax — HOW TO ELIMINATE CONDENSATION diagram (page 7)
Fig. 41
Argo Relax — HOW TO ELIMINATE CONDENSATION diagram (page 7)
Fig. 42
Page 8 of the Argo Relax user manual — OPERATING MODES
Page 8 · click to enlarge
Page 8
Argo Relax — OPERATING MODES diagram (page 8)
Fig. 43
3. Screw the drain hose into the drain hole and then secure it with the clip. Fit the other end of the hose into the cap, secure it with the clip and then run it through the clamp.
Argo Relax — OPERATING MODES diagram (page 8)
Fig. 44

Cooling Ensure that when the unit is operating in Cool mode, the rubber cap closing the drain hole on the back of the appliance is in place. To empty the container, switch the air conditioner off and unplug. Remove the cap form the rear drain hole and route its end over a normal drain. Ensure that the tube is not twisted or bent. The tube must slope downwards. Close the drain again with the cap, fit it into the clamp, and resume use of the air conditioner.

Argo Relax — OPERATING MODES diagram (page 8)
Fig. 45

Dry WARNING! When using the air conditioner in Dry mode, we recommend always ensuring continuous drainage, in order to guarantee maximum dehumidification efficiency. To empty the tank, switch the air conditioner off and pull out its plug, remove the cap from the drain hole on the back of the unit and route its end over a normal drain.

REMOTE CONTROL OPERATION Insert the batteries into the remote control, respecting the indicated polarities. Only use type AAA 1.5V batteries. Remove the batteries if the remote control is not used for a month or more. Do not attempt to recharge the batteries. Change all batteries at the same time. Do not throw batteries onto a fire, they may explode.

Argo Relax — OPERATING MODES diagram (page 8)
Fig. 46
Page 9 of the Argo Relax user manual — OPERATING MODES
Page 9 · click to enlarge
Page 9

INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE

2006/66/EC Please replace batteries when flat: at the end of their useful life, batteries must not be disposed of with unsorted waste. It must be must be delivered to appropriate separated waste disposal plants or to dealers that provide a similar service. Separate waste disposal of batteries prevents potential negative effects on the environment and human health resulting from inadequate disposal, and also allows the materials from which it is made to be recovered and recycled in order to achieve significant savings in terms of energy and resources. The separate disposal obligation is underlined by the crossed-out dustbin symbol appearing on the battery. Illegal disposal of the product by the user shall result in the application of administrative sanctions as defined by current regulations.

If you will not be using the remote control for a long time, store in its compartment on the side of the air conditioner.

Argo Relax — OPERATING MODES diagram (page 9)
Fig. 47

Press the indicated arrow

to open the compartment. Press it again to close the compartment.

FOR OPTIMAL REMOTE CONTROL FUNCTION, POINT THE HEAD OF THE TRANSMITTER TOWARDS THE RECEIVER ON THE AIR CONDITIONER.

1. ON/OFF BUTTON 2. MODE BUTTON 3. TEMPERATURE AND TIMER BUTTON 4. FAN SPEED BUTTON 5. X-FAN BUTTON 6. SLEEP BUTTON (only on remote control) 7. TIMER BUTTON (only on remote control) 8. TEMPERATURE AND ERROR DISPLAY 9. FAN SPEED DISPLAY 10. AUTO FAN SPEED DISPLAY 11. COOL MODE DISPLAY 12. REMOTE CONTROL RECEIVER 13. FAN MODE DISPLAY 14. DRY MODE DISPLAY
Argo Relax — OPERATING MODES diagram (page 9)
Fig. 48

Remote control receiver · Transmitter head · Operating display

Page 10 of the Argo Relax user manual — OPERATING MODES
Page 10 · click to enlarge
Page 10
Argo Relax — OPERATING MODES diagram (page 10)
Fig. 49

(1) ON/OFF BUTTON Press the ON/OFF button to switch the unit on or off. When switched on, the appliance will start to operate as it was last set (memory function). (2) MODE BUTTON Press this button to select the different operating modes, according to the following sequence: Cool → Dry → Fan Only → Heat (n/a)

(3) TEMPERATURE ▲▼ AND TIMER BUTTON Increase temperature(▲): 1) Enables the adjustment of the temperature desired in Cool mode. 2)Pressing the button (▲) increases the temperature by 1°C.

Decrease temperature (▼): 1) Enables the adjustment of the temperature desired in Cool mode. 2)Pressing the button (▼) decreases the temperature by 1°C. The same button is used for setting the TIMER only on remote control (see par. 7). (4) FAN SPEED BUTTON Pressing this button adjusts the fan speed when the unit is running in cool mode; the settings are AUTO, Low, Med and High.

The fan speed cannot be adjusted in DRY mode, when it is set to Low. (5) X-FAN BUTTON

Pressing the X-FAN button in cooling or dehumidification mode, when the power is turned off the fan continues to operate for about 2 minutes to completely dry the evaporator. (6) SLEEP BUTTON (remote control only)

Press this button to activate the Comfort function, which automatically adapts the temperature to changes in body and

room temperature throughout the night, to optimise comfort when sleeping and minimise consumption. (7) TIMER BUTTON (remote control only)

Press and hold this button for 1 second to set the timer.

1)Timer-on (auto-on) When the appliance is off, this button is used to set a delay after which the unit will switch itself on. The T-ON and H icons light up. Press the + and - buttons within 5 seconds to set the delay. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm. The T-ON icon will remain on to indicate that the TIMER is running.

2)Timer-off (auto-off) When the appliance is running in COOL mode, this is used to set a delay after which the unit will switch off. The T- OFF and H icons light up. Press the + and - buttons within 5 seconds to set the delay. Select a number of hours

Page 11 of the Argo Relax user manual — (8) TEMPERATURE AND ERROR DISPLAY
Page 11 · click to enlarge
Page 11

from 0.5 to 24. Press the TIMER button to confirm. The T-OFF icon will remain on to indicate that the TIMER is running. Cancelling the timer: If the TIMER is set, press TIMER to display the delay. Press TIMER again to cancel the setting.

(8) TEMPERATURE AND ERROR DISPLAY

ProblemCauseSolution E5Overcurrent protection.Pull out the plug and insert it again after 10 minutes. If the problem persists, contact a service centre. H8Tank full.Empty the tank. If the problem persists, contact a service centre. F1Temperature sensor failure.Contact a service centre. F2Evaporator temperature sensor failure.Contact a service centre. F0Refrigerant leak. Air conditioner out of service.Contact a service centre. H3The room temperature is in excess of the appliance's operating range (over 35°). The ventilation grilles are blocked.Wait for the temperature to drop below 35°C. Clear the obstruction to the ventilation grilles. If the problem persists, contact a service centre.

SAFETY FUNCTIONS LOCK REMOTE Press + and - at the same time to lock the remote control. The Lock icon will light up on the remote control, and it will not respond to commands. SWITCHING BETWEEN °C AND °F. Press - and MODE together to switch between °C and °F.

CARE AND MAINTENANCE WARNING! Before carrying out any cleaning or maintenance, unplug from the electric socket. 1. Cleaning the air filters The air filter must be checked at least once every two weeks of use. Operating with dirty or blocked filters will decrease the effectiveness of the air conditioner and can cause serious problems. To remove the filter, release the rear grille and carefully pull the filter out sideways.

Argo Relax — (8) TEMPERATURE AND ERROR DISPLAY diagram (page 11)
Fig. 50

Use a vacuum cleaner to remove dust. If this is not sufficient, wash it with lukewarm water and some neutral detergent (if necessary), rinse it thoroughly in cold water and leave to dry in air before restoring it. Once the filter has been replaced, close the grille and return to using the air conditioner.

Argo Relax — (8) TEMPERATURE AND ERROR DISPLAY diagram (page 11)
Fig. 51
Page 12 of the Argo Relax user manual — www.argoclima.com
Page 12 · click to enlarge
Page 12

2. Cleaning the casing Use a damp and soft cloth to clean the exterior surface of the air conditioner. Do not use water that is too hot, solvents, petrol or other aggressive chemical compounds, talcum powder or brushes: these may damage the surface or colour of the casing. To remove stains use warm water with a little neutral detergent. Do not pour water onto the air conditioner to clean it: this may damage the internal components or cause a short circuit. 3. Storage. When you do not envisage using the air conditioner for a long time, before storing it away, clean the filters. Keep the appliance in a vertical position at all times. Do not rest heavy objects on the top and, if possible, protect the air conditioner with a sheet of plastic. 4. Transport If possible, transport the air conditioner in a vertical position. If not possible, lie it on its right side; when you reach your destination, immediately return the appliance to a vertical position and wait at least 4 hours before using it to cool. 5. For complete safety, regularly check the condition of the power cord; if it should be damaged through use, to replace it contact the Service Centre.

Argo Relax — ADVICE FOR MAXIMUM COMFORT AND MINIMUM CONSUMPTION CHECK that: diagram (page 12)
Fig. 52 · ADVICE FOR MAXIMUM COMFORT AND MINIMUM CONSUMPTION C…
Argo Relax — ADVICE FOR MAXIMUM COMFORT AND MINIMUM CONSUMPTION CHECK that: diagram (page 12)
Fig. 53 · ADVICE FOR MAXIMUM COMFORT AND MINIMUM CONSUMPTION C…

ADVICE FOR MAXIMUM COMFORT AND MINIMUM CONSUMPTION CHECK that:

  • the unit suction and delivery grilles are always free;
  • the air filters are always clean; a dirty filter will decrease the passage of air and reduce the unit performance;
  • doors and windows are closed, to avoid the infiltration of unconditioned air;
  • the flexible hose is correctly positioned, without sharp bends or curves;
  • the room temperature is above 18ºC for Cool mode, 10ºC for Dry mode. REGULATION (EU) N. 517/2014 - F-GAS The unit contains R410A, a fluorinated greenhouse gas with global warming potential (GWP) = 2087.50. Do not release R410A into the atmosphere.

INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2012/19/EU This appliance may not be scrapped with domestic waste at the end of its life cycle. We call your attention to the crucial role played by the consumer in the re-use, recycling and other forms of recovery of such waste. The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer (no charge is levied for this service), when you purchase a new equivalent appliance. Sorted disposal of electric and electronic equipment prevents the negative effects on the environment and human health resulting from improper scrapping, and also allows the materials from which it is made to be recovered and recycled, with significant savings in terms of energy and resources. The sorted disposal requirement is indicated by the crossed wastebin label affixed to the appliance.

www.argoclima.com

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
E5Overcurrent protection.Pull out the plug and insert it again after 10 minutes. If the problem persists, contact a service centre. p.11
H8Tank full.Empty the tank. If the problem persists, contact a service centre. p.11
F1Temperature sensor failure.Contact a service centre. p.11
F2Evaporator temperature sensor failure.Contact a service centre. p.11
F0Refrigerant leak. Air conditioner out of service.Contact a service centre. p.11
H3The room temperature is in excess of the appliance's operating range (over 35°). The ventilation grilles are blocked.Wait for the temperature to drop below 35°C. Clear the obstruction to the ventilation grilles. If the problem persists, contact a service centre. p.11

Ask about the Argo Relax

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Argo Relax

Be the first to ask — other owners or our team will answer.

Original document

Argo Relax manual PDF

12 pages·3.3 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…