MODE D’EMPLOIp.1INSTRUCTION MANUALp.1ISTRUZIONI PER L’USOp.1MANUAL DE INSTRUCCIONESp.1BEDIENUNGSANLEITUNGp.1MANUAL DE INSTRUÇÕESp.1SYSTÈMES DE CHAUFFAGE / CLIMATISATIONp.1AVEC POMPE À CHALEUR SPLIT INVERTERp.1HEATING/COOLING SYSTEMS WITH INVERTER SPLIT HEAT PUMPp.1SISTEMA DI RISCALDAMENTO / CLIMATIZZAZIONEp.1CON POMPA DI CALORE SPLIT INVERTERp.1SISTEMAS DE CALEFACCIÓN / CLIMATIZACIÓNp.1CON BOMBA DE CALOR SPLIT INVERTERp.1HEIZUNGS-/KLIMAANLAGEN MIT SPLIT INVERTER WÄRMEPUMPEp.1SISTEMAS DE AQUECIMENTO / CLIMATIZAÇÃOp.1COM BOMBA DE CALOR SPLIT INVERTERp.1DANGERp.1CONTENTSp.2PRODUCT INFORMATIONp.2DECLARATION OF CONFORMITYp.2ALERT SYMBOLSp.21 - INSTALLATION LOCATIONp.32 - ELECTRICAL REQUIREMENTSp.33 - SAFETY INSTRUCTIONSp.34 - PRESENTATION OF MAIN ELEMENTSp.45 - HEAT PUMP OPERATING PRINCIPLEp.56 - CONTROL UNIT OPERATIONp.56.1 - TEMPERATURES DISPLAY Zone selection with key Z/OKp.56.2 - COOLING MODE - Activated according to the type of installationp.6COOLp.66.3 - HEATING MODEp.66.3.1 - Comfort modep.66.3.2 - Economy modep.66.3.3 - Long-term absence mode (away) - Frost protectionp.66.3.4 - Hourly programming modep.66.4 - DOMESTIC HOT WATER PREPARATION (DHW)p.76.5 - TIME AND DATE ADJUSTMENTp.76.6 - PROGRAMMINGp.76.7 - STOPp.76.8 - PARAMETERISATION From any knob position, simultaneously press and hold keysp.8List of parameters that can be consulted by the user:p.8DHW valve position fault (if the function is activated)p.97 - TROUBLESHOOTING AND MAINTENANCEp.107.1 - TROUBLESHOOTINGp.107.2 - MAINTENANCEp.118 - SYSTEM OPERATING RECOMMENDATIONSp.11
Page 1 of the Argo Hydrokit user manual — DANGER
Page 1 · click to enlarge
Page 1

10 11 530_01 Couv.qxd 15/02/10 15:11 Page 1

Conserver ce mode d’emploi Save these instructions Conservate queste istruzioni Guarde estas instrucciones Bewahren Sie bitte diese Bedienungsanleitung auf Guarde estas instruções

Argo Hydrokit — MODE D’EMPLOI diagram (page 1)
Fig. 1

MODE D’EMPLOI

INSTRUCTION MANUAL

ISTRUZIONI PER L’USO

MANUAL DE INSTRUCCIONES

BEDIENUNGSANLEITUNG

MANUAL DE INSTRUÇÕES

SYSTÈMES DE CHAUFFAGE / CLIMATISATION

AVEC POMPE À CHALEUR SPLIT INVERTER

HEATING/COOLING SYSTEMS WITH INVERTER SPLIT HEAT PUMP

SISTEMA DI RISCALDAMENTO / CLIMATIZZAZIONE

CON POMPA DI CALORE SPLIT INVERTER

SISTEMAS DE CALEFACCIÓN / CLIMATIZACIÓN

CON BOMBA DE CALOR SPLIT INVERTER

HEIZUNGS-/KLIMAANLAGEN MIT SPLIT INVERTER WÄRMEPUMPE

SISTEMAS DE AQUECIMENTO / CLIMATIZAÇÃO

COM BOMBA DE CALOR SPLIT INVERTER

Février 2010 37.4163.340.00 10 11 530 - F.GB.I.E.D.P - 01

DANGER

Page 2 of the Argo Hydrokit user manual — Table of Contents
Page 2 · Contents
Contents

Contents

MODE D’EMPLOIp.1INSTRUCTION MANUALp.1ISTRUZIONI PER L’USOp.1MANUAL DE INSTRUCCIONESp.1BEDIENUNGSANLEITUNGp.1MANUAL DE INSTRUÇÕESp.1SYSTÈMES DE CHAUFFAGE / CLIMATISATIONp.1AVEC POMPE À CHALEUR SPLIT INVERTERp.1HEATING/COOLING SYSTEMS WITH INVERTER SPLIT HEAT PUMPp.1SISTEMA DI RISCALDAMENTO / CLIMATIZZAZIONEp.1CON POMPA DI CALORE SPLIT INVERTERp.1SISTEMAS DE CALEFACCIÓN / CLIMATIZACIÓNp.1CON BOMBA DE CALOR SPLIT INVERTERp.1HEIZUNGS-/KLIMAANLAGEN MIT SPLIT INVERTER WÄRMEPUMPEp.1SISTEMAS DE AQUECIMENTO / CLIMATIZAÇÃOp.1COM BOMBA DE CALOR SPLIT INVERTERp.1DANGERp.1CONTENTSp.2PRODUCT INFORMATIONp.2DECLARATION OF CONFORMITYp.2ALERT SYMBOLSp.21 - INSTALLATION LOCATIONp.32 - ELECTRICAL REQUIREMENTSp.33 - SAFETY INSTRUCTIONSp.34 - PRESENTATION OF MAIN ELEMENTSp.45 - HEAT PUMP OPERATING PRINCIPLEp.56 - CONTROL UNIT OPERATIONp.56.1 - TEMPERATURES DISPLAY Zone selection with key Z/OKp.56.2 - COOLING MODE - Activated according to the type of installationp.6COOLp.66.3 - HEATING MODEp.66.3.1 - Comfort modep.66.3.2 - Economy modep.66.3.3 - Long-term absence mode (away) - Frost protectionp.66.3.4 - Hourly programming modep.66.4 - DOMESTIC HOT WATER PREPARATION (DHW)p.76.5 - TIME AND DATE ADJUSTMENTp.76.6 - PROGRAMMINGp.76.7 - STOPp.76.8 - PARAMETERISATION From any knob position, simultaneously press and hold keysp.8List of parameters that can be consulted by the user:p.8DHW valve position fault (if the function is activated)p.97 - TROUBLESHOOTING AND MAINTENANCEp.107.1 - TROUBLESHOOTINGp.107.2 - MAINTENANCEp.118 - SYSTEM OPERATING RECOMMENDATIONSp.11
Page 3 of the Argo Hydrokit user manual — 3 - SAFETY INSTRUCTIONS
Page 3 · click to enlarge
Page 3

1 - INSTALLATION LOCATION

  • This apparatus must be installed by a qualified technician and in compliance with the instructions provided .
  • Prior to installation, check that the installation's mains voltage corresponds to that indicated on the rating plate.
  • The indoor unit must be installed in a frost protection location.
  • Do not install the indoor unit in an area where gaseous emanations or flammable gases may be present, or in a very humid location such as a laundry room.
  • Do not install the indoor unit in a location containing elements that release an excessive amount of heat.
  • Do not store objects near the outdoor unit so as not to disrupt good airflow around the exchanger.
  • Avoid: To protect the unit from corrosion, avoid installing the outdoor unit in a location where there is a risk of it being sprayed with seawater or in an aggressive or sulphurous environment (for example, near a hotspring).

2 - ELECTRICAL REQUIREMENTS

1. All cables and their installation must comply with current standards and regulations. For further details, consult your installer. 2. All elements must be properly grounded. 3. The electrical connections must be performed by a qualified technician.
  • To warm up the system, the power mains must be turned on at leats five (5) hours before operation. Leave the power mains ON unless you will not be using this appliance for an extended period.

3 - SAFETY INSTRUCTIONS

  • Read this Instruction Manual carefully before using the apparatus. If you still have any difficulties or problems, consult your dealer for help.
  • The apparatus is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.
Page 4 of the Argo Hydrokit user manual — 4 - PRESENTATION OF MAIN ELEMENTS
Page 4 · click to enlarge
Page 4
  • Never touch the units with wet hands.
  • Never wet or spray the units with water.
  • Never use or store gasoline or any other flammable liquids or vapours near the units, as such practices are extremely dangerous.
  • Do not remove the protective covers from the units.
  • Never turn the unit on or off using the system power supply switch. Use the ON/OFF button.
  • Do not introduce anything into the outdoor unit's air outlet. This is very dangerous as the fan turns at high speed.
  • Do not cool or heat the room too much if babies or invalids are present.
  • This appliance is not designed to be used by people (including children) whose physical, sensory or mental capacities are impaired, or who lack experience or knowledge, unless they are supervised or have received instructions on how to use the appliance by a person who is responsible for their safety. Children must be supervised to ensure that they do not play with the appliance or its accessories.
  • Consult approved professionals to perform the maintenance and troubleshooting operations.

4 - PRESENTATION OF MAIN ELEMENTS

Outdoor unitIndoor unitControl unit2-zone hydraulic module if installedDomestic Hot Water (DHW) production tank if installed Installed outside the homeInstalled in a sheltered and frost protection equipment roomInstalled inside the home within the unit's operating environmentInstalled in a sheltered and frost protection equipment roomInstalled in a sheltered and frost protection equipment room
Argo Hydrokit — 4 - PRESENTATION OF MAIN ELEMENTS diagram (page 4)
Fig. 2
Argo Hydrokit — 4 - PRESENTATION OF MAIN ELEMENTS diagram (page 4)
Fig. 3
Page 5 of the Argo Hydrokit user manual — 6.1 - TEMPERATURES DISPLAY Zone selection with key Z/OK
Page 5 · click to enlarge
Page 5

5 - HEAT PUMP OPERATING PRINCIPLE

  • The outdoor unit "captures" heat and transfers it to the indoor unit via a refrigerant connection. The indoor unit then delivers this heat into the home through a hydraulic circuit capable of supplying various types of transfer units (floor, low-temperature radiators, fan-coil units, and Domestic Hot Water (DHW) production tank...).
  • The built-in control manages the system that supplies the hydraulic system with a water temperature adapted to current needs and according to the operating mode selected on the control unit.
  • For installations with radiators or fan-coil units, the ambient temperature can be adjusted by means of commands specific to this type of transfer unit.

6 - CONTROL UNIT OPERATION

Current program (Comfort, : Economy) Comfort override activated

Display zone 1, zone 2 (if any) or outside temperature

Modification or override keys

Validation or zone change key

DHW cycle in progress (if any) (Blinking if alarm on the DHW) Economy

6.1 - TEMPERATURES DISPLAY Zone selection with key Z/OK

1 2 3 4 5 6 7

1 2 3 4 5 6 7

1 2 3 4 5 6 7

0h 2 4 6 8 10 12 14 16 18 20 22 24

0h 2 4 6 8 10 12 14 16 18 20 22 24

At any time, pressing and holding (5 sec.) the key will display the ambient temperature of the zone

Display of the current setpoint and program of zone 1.

Display of the current setpoint and program of zone 2 (possible).

By default, the current set point is displayed.

The cursor is displayed near the symbol when the system is operating in override with a Typhone 500 telephone remote control unit (Heating mode - ZONE 1 - only).

Show 14 more labels / short text on this page
Current day · Electric heating only · Temperatures · Button selection mark · Electric heating ON · Hourly program mode · Away · Comfort · Cooling · Stop · mode · Time setting · Hourly programming · Outside temperature display
Page 6 of the Argo Hydrokit user manual — 6.3.4 - Hourly programming mode
Page 6 · click to enlarge
Page 6
  • Two cases are possible in the case of an installation with 2 zones:
  • zone 2 = floor: the unit displays the temperatures for each zone,
  • zone 2 = terminal units: the unit displays either HEAT in heating mode or COOL in cooling mode. The configuration is determined when commissioned.

6.2 - COOLING MODE - Activated according to the type of installation

1 2 3 4 5 6 7

The setting mode is exited after 5 seconds if no key is pressed.

Set the knob to

The setpoint temperature is displayed

Cooling setpoint temperature adjustment (20°C to 30°C)

COOL

6.3 - HEATING MODE

6.3.1 - Comfort mode

1 2 3 4 5 6 7

1 2 3 4 5 6 7

The setting mode is exited after 5 seconds if no key is pressed.

0h 2 4 6 8 10 12 14 16 18 20 22 24

0h 2 4 6 8 10 12 14 16 18 20 22 24

the Comfort setpoint is displayed

Set the new Comfort setpoint from 15°C to 25°C (ex: 21.5°C)

6.3.2 - Economy mode

1 2 3 4 5 6 7

The Economy temperature is indexed to the Comfort temperature (adjustable in the installer menu). Default value: Economy = Comfort - 2°C.

0h 2 4 6 8 10 12 14 16 18 20 22 24

The Economy setpoint is displayed

6.3.3 - Long-term absence mode (away) - Frost protection

1 2 3 4 5 6 7

The frost protection temperature is 12°C - factory set (adjustable during installation)

The frost protection setpoint is displayed

6.3.4 - Hourly programming mode

1 2 3 4 5 6 7

1 2 3 4 5 6 7

1 2 3 4 5 6 7

0h 2 4 6 8 10 12 14 16 18 20 22 24

0h 2 4 6 8 10 12 14 16 18 20 22 24

0h 2 4 6 8 10 12 14 16 18 20 22 24

The unit followings the programming

Press the key as many times as necessary to select a Comfort override

If not pressed for 3 seconds, the override is validated. The hourglass icon flashes

The key enables you to go back during the override duration programming step.

Show 12 more labels / short text on this page
Set the · knob · to · Set the · knob · to · Set the · knob · to · Set the · knob · to
Page 7 of the Argo Hydrokit user manual — 6.7 - STOP
Page 7 · click to enlarge
Page 7

6.3.5 - Set point override by telephone control TYPHONE 500 • Only in heating mode (do not operate in cooling mode). The user can:

New current set point.

- know the ambient temperature of zone 1, - know the current set point temperature of zone 1, - send a common override set point for zone 1 and 2.

During override, zone 1 and 2 operate in Comfort mode with the new temperature set point. This override is indicated by an index on the display. Any action on the rotary knob deactivates the override. Note: This function is possible only after entering the password (given by the installer) by means of the phone keyboard.

Phone comfort override index

6.4 - DOMESTIC HOT WATER PREPARATION (DHW)

  • If installed - Activated according to the type of installation
  • Available on installations 1 zone heating only (No cooling).
  • Function activated during installation. Actuates the heat pump, in a cyclic way, for an adapted DHW preparation tank pre-heating.
  • A running DHW cycle can be stopped by setting the system to “ OFF ” (Then start it again in the selected function).
  • Out of the heating season, it is possible to activate this DHW function by selecting the cool mode (=“ Summer ”). At that time, message “DHW” is appearing on the display.

6.5 - TIME AND DATE ADJUSTMENT

1 2 3 4 5 6 7

1 2 3 4 5 6 7

1 2 3 4 5 6 7

The current day flashes

Select the desired day and validate by pressing OK

Set the hour using + or - and validate by pressing OK

Set the minutes using + or - and validate by pressing OK

6.6 - PROGRAMMING

1 2 3 4 5 6 7

1 2 3 4 5 6 7

Set the knob on PROG Z1

0h 2 4 6 8 10 12 14 16 18 20 22 24

0h 2 4 6 8 10 12 14 16 18 20 22 24

Validate and continue to the next day. Repeat the procedure for each day.

The 1st time slot flashes

Repeat the procedure for each time slot

Ex.: Comfort from 7h to 9h, from 12h to 14h, from 19h to 23h

To modify the programming for zone 2 (if this one is activated), set the knob to and repeat the operations above

6.7 - STOP

Set the knob to

Show 5 more labels / short text on this page
Set the · knob · to · 1 h comfort · 1 h reduced
Page 8 of the Argo Hydrokit user manual — List of parameters that can be consulted by the user:
Page 8 · click to enlarge
Page 8

6.8 - PARAMETERISATION From any knob position, simultaneously press and hold keys

1. User 2 : Installer

and for 5 seconds, until the screen displays PArA, then select User / Installer menu.

To move from the user menu to the installer menu, press or :

- = user menucertain parameters may only be consulted,

hold the and keys for 5 seconds

- = installer menuprotected access by password for

modification (for installer use only).

Select the first parameter by pressing on Z/OK.

Access to the 1st parameter (P01) Display of the parameter

Press the or keys to shift from one parameter to another.

To exit the parameterisation menu, press and hold for 5 seconds or modify the position of the selector knob.

List of parameters that can be consulted by the user:

Outside temperatureHeat pump control status Installation water return temperatureHeat pump mode control status Installation water outlet temperatureOutlet status, Support heater Elec. - 1 Resulting water temperature setpoint, ZONE 1Outlet status, Support heater Elec. - 2 Resulting water temperature setpoint, ZONE 2Outlet status, Support heater Elec. - 3 Water temperature, ZONE 1Outlet status - water pump ZONE 1 Water temperature, ZONE 2 (floor)Outlet status - water pump ZONE 2 Ambient Temperature ZONE 1Outlet status - valve control ZONE 1 Ambient Temperature ZONE 2 (floor)Outlet status - valve control ZONE 2 (heating floor)

Parameters available for installations with 2 ZONES

Simultaneously press and · value

Page 9 of the Argo Hydrokit user manual — DHW valve position fault (if the function is activated)
Page 9 · click to enlarge
Page 9

6.9 - ALARMS If an alarm message appears, contact the After-Sales Service.

The unit displays:

Heat pump fault. manual reset (*). In heating mode, the heat pump fault causes the installation to switch to Frost Protection mode. It is possible to restart in heating mode by pressing and holding OK.

The symbol is displayed.

Communication fault with heat pump. Same action as for Gr alarm. Manual reset (*).

Heater fault.

Installation water return probe fault.

Output water probe fault installation.

Water probe fault, zone 1 (in the case of 2 zones only).

Water probe fault, zone 2 (in the case of 2 zones only).

High water temperature fault. Manual reset (*).

Ext. air probe fault.

Ambiance probe fault Z1.

Ambiance probe fault, Z2 (in the case of 2 zones floor only).

Communication or system fault.

Communication fault with zone 1 board (in the case of 2 zones only).

Communication fault with zone 2 board (in the case of 2 zones only).

Heat pump water flow fault. Manual reset (*).

DHW valve position fault (if the function is activated)

disconnecting the power of the apparatus). Call the after-sales service.

Page 10 of the Argo Hydrokit user manual — 7.1 - TROUBLESHOOTING
Page 10 · click to enlarge
Page 10

7 - TROUBLESHOOTING AND MAINTENANCE

7.1 - TROUBLESHOOTING

PROBLEMPOSSIBLE CAUSEACTION The control unit is turned off.Indoor unit power supply circuit breaker has tripped (open). Circuit breaker of the indoor unit control circuit has tripped (open) (accessible via the window on the right-hand side of the indoor module).Contact the After-Sales Service Department. Contact the After-Sales Service Department. The system does not operate at all.The function switch is set to "OFF". An alarm is displayed on the control unit (see list in paragraph 6.9). Outdoor unit power supply circuit breaker has tripped (open). Line voltage very low.Select the desired mode. Contact the After-Sales Service Department. Contact the After-Sales Service Department. Consult the installer. The outdoor unit starts but stops rapidly.Obstacle in front of the unit's exchanger.Clear a space around the unit. Insufficient heating (or cooling).Doors and/or windows are open. Heat source in cooling mode. Setpoints (set on the control unit) are inappropriate (too low in heating mode / too high in cooling mode). Incorrect settings on radiator and fan-coil unit thermostats (if any). Air filter on terminal units (if any) obstructed or dirty. Low water pressure on the hydraulic system (see pressure gauge on front of indoor unit). Hydraulic system poorly purged. Faulty outdoor unit defrosting.Close. Remove the source of heat. Modify the settings. Modify the settings. Clean the filter. Add water to the system. If the problem continues, call After-Sales Service. Purge the system. If the problem continues, call After-Sales Service. Contact the After-Sales Service Department.
Page 11 of the Argo Hydrokit user manual — 8 - SYSTEM OPERATING RECOMMENDATIONS
Page 11 · click to enlarge
Page 11

7.2 - MAINTENANCE

  • A yearly verification (or during a restart) is to be performed by an approved technical service centre.
  • Cleaning.
1. Be safe! Turn the unit off and disconnect the electric power supplies. 2. Do not pour water on the units to clean them. This will damage the internal components and cause an electric shock hazard.
1. Never use solvents or powerful chemical products. Do not wipe plastic parts using very hot water. 2. As certain metal edges may be sharp, handle elements with caution when cleaning them. 3. Certain components (such as the outdoor unit heat exchanger) and the filters installation must be cleaned regularly. These operations must be performed by an approved technical service centre.

8 - SYSTEM OPERATING RECOMMENDATIONS

  • Make sure that doors and windows are correctly closed.
  • Correctly set the temperature setpoints to the desired values. Each additional degree of heating (or cooling) results in a significant increase in energy consumption.
  • Remember to use the “ Eco ” and “ Frost-Protection ” modes.
  • For reversible installations, be sure to respect a minimum rest period (“ OFF ”) of 2 to 3 hours when switching from heating mode to cooling mode (or from cooling mode to heating mode).
  • Ensure that all terminal units, if any, are in good operating condition (air inlets and outlets clear, clean filter).
Page 12 of the Argo Hydrokit user manual — 7.2 - MAINTENANCE
Page 12 · click to enlarge
Page 12

10 11 530_01 Fin.qxd 15/02/10 11:45 Page 74

Page 13 of the Argo Hydrokit user manual — 7.2 - MAINTENANCE
Page 13 · click to enlarge
Page 13

10 11 530_01 Fin.qxd 15/02/10 11:45 Page 75

Votre produit est conçu et fabriqué avec des matériels et des composants de qualité supérieure qui peuvent être recyclés et réutilisés. En fin de vie, il doit être éliminé séparément des ordures ménagères. Nous vous prions donc de confier cet équipement à votre centre local de collecte/recyclage. Dans l’Union Européenne, il existe des systèmes sélectifs de collecte pour les produits électriques et électroniques usagés. Aidez-nous à conserver l’environnement dans lequel nous vivons ! Les appareils contiennent fréquemment des matières qui, si elles sont traitées ou éliminées de manière inapropriées, peuvent s’avérer potentiellement dangereuses pour la santé humaine et pour l’environnement. Cependant, ces matières sont nécessaires au bon fonctionnement de votre appareil ou de votre machine. Pour cette raison, il vous est demandé de ne pas vous débarrasser de votre appareil ou machine usagé avec vos ordures ménagères.

Your product is designed and manufactured with high quality materials and components which can be recycled and reused. At end of livetime, it should be eliminated separately from your household waste. Please dispose of this equipment at your local community waste collection/recycling centre. In the European Union there are separate collection systems for used electrical and electronic products. Please help us to conserve the environment we live in! Some equipments contain substances that are considered dangerous to the environment and human health if they are disposed of carelessly. These substances, however, are required for your apparatus or machine to work properly. For this reason, it is requested that it not be disposed of with other household waste at the end of its service life.

Il vostro prodotto è stato costruito da materiali e componenti di alta qualità, che sono riutilizzabili o riciclabili. Alla fine della sua vita utile deve essere smaltito separatamente dai rifiuti domestici. Vi preghiamo di smaltire questo apparecchio in un centro di raccolta differenziata locale. Nell'Unione Europea esistono sistemi di raccolta differenziata per prodotti elettrici ed elettronici. Aiutateci a conservare l'ambiente in cui viviamo! Gli apparecchi contengono spesso dei materiali che, se trattati od eliminati in modo non adeguato, possono dimostrarsi potenzialmente pericolosi per la salute umana e per l'ambiente. Tuttavia, questi materiali sono necessari per il corretto funzionamento del vostro apparecchio o della vostra macchina. Per questo motivo, si richiede di non eliminare il proprio apparecchio o macchina usata assieme ai rifiuti domestici comuni.

Los productos están diseñados y fabricados con materiales y componentes de alta calidad, que pueden ser reciclados y reutilizados. Al final de su ciclo de vida, no se debe desechar con el resto de residuos domésticos. Por favor, deposite su viejo “televisor” en el punto de recogida de residuos o contacte con su administración local. En la Unión Europea existen sistemas de recogida específicos para residuos de aparatos eléctricos y electrónicos. Por favor, ayúdenos a conservar el medio ambiente! Los aparatos a menudo contienen materiales que, si son tratados o eliminados de forma inadecuada, pueden convertirse en potencialmente peligrosos para la salud humana y para el medio ambiente. No obstante, estos materiales son necesarios para el buen funcionamiento de su máquina. Por esta razón, le rogamos encarecidamente que al final de la vida útil de su aparato, no lo tire junto con la basura doméstica, sino que lo recicle adecuadamente.

Ihr Produkt wurde entworfen und hergestellt mit qualitativ hochwertigen Materialien und Komponenten, die recycelt und wiederverwendet werden können. Am Ende ihrer Nutzungsdauer muss er getrennt vom Hausmüll eliminier werden sollen. Bitte entsorgen Sie dieses Gerät bei Ihrer örtlichen kommunalen Sammelstelle oder im Recycling Centre. In der Europäischen Union gibt es unterschiedliche Sammelsysteme für Elektrik- und Elektronikgeräte. Helfen Sie uns bitte, die Umwelt zu erhalten, in der wir leben! Die Geräte enthalten häufig Bestandteile aus bestimmten Werkstoffen, die bei einer nicht ordnungsgemäßen Behandlung oder Entsorgung eine Belastung für die menschliche Gesundheit und Umwelt darstellen. Diese Werkstoffe sind jedoch für die korrekte Funktionsweise Ihres Gerätes oder Maschine notwendig. Daher bitten wir Sie, Ihr(e) ausgediente(s) Gerät/Maschine nicht in den Hausmüll zu geben.

O seu produto foi concebido e produzido com materiais e componentes de alta qualidade que podem ser reciclados e reutilizados. No final da sua vida útil deverá ser descartado separadamente do seu lixo doméstico. Por favor, entregue este equipamento no seu ponto local de recolha / reciclagem. Na União Europeia existem sistemas de recolha separados para produtos eléctricos e electrónicos usados. Por favor, ajude-nos a conservar o ambiente em que vivemos! Os aparelhos contêm, frequentemente, substâncias que, se forem tratadas ou eliminadas de maneira incorrecta, podem revelar-se potencialmente perigosas para a saúde humana e para o ambiente. Contudo, estas matérias são necessárias para o bom funcionamento do aparelho ou da máquina. Por este motivo, solicita- se que não se deite fora o aparelho ou a máquina com os resíduos domésticos.

Page 14 of the Argo Hydrokit user manual — 7.2 - MAINTENANCE
Page 14 · click to enlarge
Page 14

10 11 530_01 Fin.qxd 15/02/10 11:45 Page 76

Par souci d'amélioration constante, nos produits peuvent être modifiés sans préavis. Due to our policy of continuous development, our products are liable to modification without notice. Per garantire un costante miglioramento dei nostri prodotti, ci riserviamo di modificarli senza preaviso.

En el interés de mejoras constantes, nuestros productos pueden modificarse sin aviso prévio. Unsere Produkte werden laufend verbessert und können ohne Vorankündigung abgeändert werden. Com o objectivo de uma melhoria constante, os nossos produtos podem ser modificados sem aviso prévio.

R.D. 28 Reyrieux BP 131 01601 Trévoux CEDEX France Tél. 04 74 00 92 92 - Fax 04 74 00 42 00 Tel. 33 4 74 00 92 92 - Fax 33 4 74 00 42 00 R.C.S. Bourg-en-Bresse B 759 200 728

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
The control unit is turned off.Indoor unit power supply circuit breaker has tripped (open). Circuit breaker of the indoor unit control circuit has tripped (open) (accessible via the window on the right-hand side of the indoor module).Contact the After-Sales Service Department. Contact the After-Sales Service Department. p.10
The system does not operate at all.The function switch is set to "OFF". An alarm is displayed on the control unit (see list in paragraph 6.9). Outdoor unit power supply circuit breaker has tripped (open). Line voltage very low.Select the desired mode. Contact the After-Sales Service Department. Contact the After-Sales Service Department. Consult the installer. p.10
The outdoor unit starts but stops rapidly.Obstacle in front of the unit's exchanger.Clear a space around the unit. p.10
Insufficient heating (or cooling).Doors and/or windows are open. Heat source in cooling mode. Setpoints (set on the control unit) are inappropriate (too low in heating mode / too high in cooling mode). Incorrect settings on radiator and fan-coil unit thermostats (if any). Air filter on terminal units (if any) obstructed or dirty. Low water pressure on the hydraulic system (see pressure gauge on front of indoor unit). Hydraulic system poorly purged. Faulty outdoor unit defrosting.Close. Remove the source of heat. Modify the settings. Modify the settings. Clean the filter. Add water to the system. If the problem continues, call After-Sales Service. Purge the system. If the problem continues, call After-Sales Service. Contact the After-Sales Service Department. p.10

Ask about the Argo Hydrokit

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Argo Hydrokit

Be the first to ask — other owners or our team will answer.

Original document

Argo Hydrokit manual PDF

14 pages·3.1 MB·Climate Controle Miscellaneous·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…