Emix Tank 200 V2 Emix Tank 300 V2
04/2017


This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
If necessary, get help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sale/service outlet or your certified dealer for additional instructions.
In case of improper installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.
SPECIAL PRECAUTIONS • During installation, connect before the refrigerant and hydraulic system and then the wiring one; proceed in the reverse order when removing the units.
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIANS SHOULD ATTEMPT TO WIRE THIS SYSTEM.
When transporting Be careful when picking up and moving the unit. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminium fins on the unit can cut your fingers. When installing Make sure the floor is strong enough to hold the unit-weight. It may be necessary to build a strong wooden or metal frame to provide added support.
Properly insulate any tubing run inside a room to prevent “sweating”, which can cause dripping and water damage to walls and floors.

In the absence of the precautions described above, THE MANUFACTURER shall not be held responsible for any damage caused.

Tools required for installation (not supplied)
Emix Tank is an innovative indoor unit, able to provide domestic hot water from a thermodynamic source all year round, i.e. independently of the system’s operating mode.
The purpose of Emix Tank is to produce domestic hot water through storage, using the energy produced directly from the heat pump (therefore renewable energy) and providing the service at the same time as heating and cooling the environ- ments.
Emix Tank is both a proper heat pump tank and a full feature electrical water heater.
Emix Tank is connected to the proper EMIX port of the heat pump (except outdoor units G30 and G42 where it can be connected to a normal port, using the adapter from 3/8” to 1/4” for the liquid return fl are, included with the outdoor unit). Further informations in the paragraph “ Only DHW application”.
Anyway, in case of outdoor unit failure, you can use Emix Tank as electrical water heater without the heat pump.

Emix Tank must be connected to an outdoor unit compatible with Emix. For specifi c models see catalogue.(*)
(*) The models WITHOUT EMIX PORT can not support this new device for the production of domestic hot water.
This manual will use some models abbreviations of compatible outdoor units of the catalogue (Example G30 means AEI1G30EMX-GR9FI30).
The following diagram illustrates the concept exposed above and shows a system confi guration where three indoor direct expansion units, a hydrokit for a fl oor system and an Emix Tank coexist, all connected to a G110.

Emix Tank always works in heating mode even when the heat pump is working for cooling of the environments; during this operation mode, Emix Tank is able to recover the heat which would otherwise be lost in the outdoor air, signifi cantly increasing the energy effi ciency of the entire system.
There are several possible confi gurations with Emix Tank and the one represented in the previous fi gure is just one of many.

Emix Tank is a component that may be connected with other indoor units at the same time by using the special connec- tion for Emix and duly considering the length of the Emix Tank pipe to be added to the total length set by the outdoor unit (we advise a specifi c insulation of the Emix Tank pipes to guarantee the minimum dispersion of energy).

H
H3
FOR TUBING LENGTH AND ELEVATION DIFFERENCE LIMIT SEE INSTALLATION INSTRUCTIONS OF OUTDOOR UNIT. CONSIDER EMIX TANK AS AN INDOOR UNIT OF THE SYSTEM. FOR THE BEST PERFORMANCE, KEEP EMIX TANK TUBING AS SHORT AS POSSIBLE (MAX. 10m).
Additional refrigerant charge for Emix Tank line (if needed) is : 15 g/m for tubing 3/8” - 3/8” or 20g/m for tubing 1/2” - 1/2”.
G80 limit (in application 4 units), without additional load, is 40 meters. The system is ok.
G80 limit (in application 4 units), with additional load, is 65 meters. You have to add: 15 g/m x 17 m.
Refrigerant Circuit · Example n° 1

The cover can be removed by pulling it out from the bottom. When the cover is partially removed, pull it towards you.

MAIN PARTS 1



200 LITRE UNIT 1460 mm 300 LITRE UNIT 1875 mm
200 LITRE UNIT 103 Kg 300 LITRE UNIT 133 Kg
NOTES
In the absence of such a precaution, the intervention of the safety valve could cause damage to people, animals and things and THE MANUFACTURER can not be held responsible.
210 210 200

G30 / G42 ONLY DHW (SEE SECTION “ONLY DHW APPLICATION”)
R410A, 3/8” IN R410A, 3/8” OUT
G140

R410A, IN (X) is the pipe from the outdoor unit R410A, OUT (Y) is the pipe to the outdoor unit
Pay the max. attention to respect the sense of these connections, both if you are using Emix Tank connected to the Emix port or the standard port of the outdoor unit.
- connect the port (X) of outdoor unit to the pipe R410A, IN (X) of Emix Tank - connect the port (Y) of outdoor unit to the pipe R410A, OUT (Y) of Emix Tank
- connect the gas pipe 3/8” of outdoor unit to the pipe R410A, IN (X) of Emix Tank - connect the liquid pipe 1/4” of outdoor unit to the pipe R410A, OUT (Y) of Emix Tank
Use the adapter indicated in the fi gure.
Emix Tank

HYDRAULIC CONNECTION BETWEEN EMIX TANK AND DOMESTIC WATER CIRCUIT
Here below you can see the water connections and how to set the thermostatic mixing valve.

F
Expansion vessel installation is always warmly recommended in order to prevent hydraulic issues to Emix Tank unit (e.g. due to suddenly pressure change in the water inlet circuit) and, most of all, to counteract the pressure in- creasing due to water heating.

Connect here the discharge valve and the expansion vessel


Place the fl ow switch on the domestic hot water tap as shown in fi gure. Connect the fl ow switch to the connector J14 on the main board.
Convention: if there is fl ow (tapping) the switch must be closed (dry contact).


THE FRONT PANEL AND THE COVER OF ELECTRICAL CONNECTIONS MUST BE FASTENED SECURELY DURING OPERATION OF THE UNIT.

TERMINAL BLOCKS AND ELECTRICAL CONNECTIONS


electrical line.
Main switch for disconnection from the supply line must have a contact separation in all poles that provides full disconnection under category III overvoltage conditions.
Connect the communication shielded pair cable to the connection block C1 and C2 taking care about polarity between outdoor unit and Emix Tank. Connect the shield to the communication ground connection. In case of mistake you will see a communication error indication (all the LED fl ashing). SEE AUTO-DIAGNOSIS TABLE. REMOTE CONTROL is a connection giving you the opportunity to control the Emix Tank by a remote wired connection, for example by a Solar Panel Control Box or a Timer. (See the section “Home Automation Connections”). The label of the electric wiring diagram is applied on the electrical box panel.
Setting of electrical heater elements The electrical heater elements of Emix Tank are both enabled (factory setting). It is possible to change this setting utilizing the switch SW1 in order to exclude the lower element or the upper one, but you must anyway let at least one electric heater element enabled. Failure to use at least one electrical heater element could affect the proper operation of the system; besides this, in case of failure of outdoor unit, the electrical heaters provide heating of the water.
Factory setting 1 element 1kW lower 2 elements 1+1kW lower +
1 element 1kW upper
upper

A B
L ( m ) S ( mm2) L ( m ) S ( mm2)
Supply power wire A: Multipolar electric wire. Size and length of the suggested electric wire are showed on table. The wire must be Mod. H07RN-F (according to CEI 20-19 CENELEC HD 22). Make sure the length of the conductors between the fixing point and the terminals allows the straining of the conductors L, N before that of the grounding Connecting wire B (SHIELDED): Bipolar electric shielded wire; size and length of the suggested electric wire are showed in the Installation Instructions of outdoor unit (consider Emix Tank as an indoor unit). The wires have not to be lighter than Mod. H05VVC4V5-K (according to CEI 20-20 CENELEC HD21).
Home Automation connections It is possible to connect Emix Tank to an Home Automation system, according to the following instructions:
Use terminals O and O (see WIRING DIAGRAM) for connection to an external input signal that is used to activate or deactivate Emix Tank unit (dry contact, bridged at the factory); such as a solar controller that activates or deactivates Emix Tank according to its heating requirements, or a programmer for service activation at different times. For connection, remove the factory-installed jumper and connect the external controller. Convention: CONTACT OPEN: EMIX TANK STANDBY CONTACT CLOSED: EMIX TANK OPERATING



Flow switch connection on DHW (optional) Connect the fl ow switch to the connector J14. SEE SECTION G
JP1= CLOSED
JP2= CLOSED
JP1 JP2
JP3= CLOSED (DO NOT CHANGE)
JP4= OPEN (DO NOT CHANGE)
JP3
JP4
JP1 Application type selection: CLOSED: connect the unit to the special Emix port (when Emix Tank is part of a system). OPEN: Connect the unit to refrigerant port on the outdoor unit (if there is no Emix port) - see DHW application with outdoor unit G30 / G42.
JP2 Internal use. Do not change factory setting. If changed, the unit will not run properly.
JP3 Internal use. Do not change factory setting. If changed, the unit will not run properly.
JP4 Internal use. Do not change factory setting. If changed, the unit will not run properly.

See section “Setting of electrical heater elements”.
Set SW3 in order to select the water volume of the tank. SW3 is pre-set in the factory
OFF - OFF = 300 l ON - OFF = 200 l
Emix Tank unit can be used with outdoor unit G30 and G42 in a specifi c confi guration in order to create an heat pump system only for DHW production.

Only DHW application: G30 / G42 + Emix Tank Connect Emix Tank unit to the only refrigerant port (G30) or to the refrigerant port A (G42) on the outdoor unit, using 1/4 ->3/8 adapter provided with outdoor unit. The system will operate always in heating mode. Remove JP1 from PCB of Emix Tank unit before switching on the system. In this application, you can not connect other indoor units to G42.
Emix Tank could be connected to any type of thermal solar forced circulation system (see example in the system layout). The panel will be connected directly to the coil inside Emix Tank unit (the connections are in the lower part of the tank). The temperature sensor of the tank for the solar thermal system can be placed in its thermowell in the lower part of the unit (accessible by removing the lower panel - see section C).


How to disconnect the refrigerant circuit In case of Emix Tank is connected to a normal indoor unit port, (for example with G30 or G42) the unit must be discon- nected exactly as any other indoor unit. On the outdoor unit, electrically disconnect the reversing valve to force the system in cooling.
In case of Emix Tank is connected to the Emix port and by any reason it has to be disconnected and replaced, the installer has to do this procedure using a refrigerant recovery unit:
In case of Emix Tank is connected to the Emix port and by any reason it has to be removed defi nitively, the installer has to do this procedure using a refrigerant recovery unit:
INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE 2012/19/EU
At the end of its working life this equipment must not be disposed of as an household waste. It must be taken to special local community waste collection centres or to a dealer providing this service. Disposing of an electrical and electronic equipment separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to be recovered and recycled to obtain significant savings in energy and resources. In order to underline the duty to dispose of this equipment separately, the product is marked with a crossed-out dustbin.


6 Thermostatic mixing valve (installed on Emix Tank unit)
BUS (bipolar electric shielded wire min. 0,75 mm2)


BUS (bipolar electric shielded wire min. 0,75 mm2)
5 Polyphosphate filter or softener (not supplied) 6 Thermostatic mixing valve (installed on Emix Tank unit)
1 EMX outdoor unit 2 Emix Tank 200/300 3 Expansion vessel 18 liters minumum (not supplied;
8 Solar coil connection 9 Forced circulation solar system 10 Flow switch (optional, not supplied)


6 Thermostatic mixing valve (installed on Emix Tank unit)
BUS (bipolar electric shielded wire min. 0,75 mm2)
BUS (bipolar electric shielded wire min. 0,75 mm2)

Read this booklet carefully before using this appliance. If you still have any difficulties or problems, consult your dealer
for help.
This appliance is designed to give you domestic hot water. Use this only for its intended purpose as described in this
Instruction Manual.
Never use or store gasoline or other flammable vapour or liquid near the unit. It is very dangerous.
Never install electrical equipment, which is not protected with IPX1 protection (protection against vertical water drop),
under the unit.
Never touch the units with wet hands.
The manufacturer assumes no responsibilities if the safety regulations or local codes are not observed.
Never use the power main switch to start or stop the air conditioner: always use the selector switch on the unit.
Do not let children play with the appliance.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the air conditioner by a person responsible for their safety.
Safety instructions

The control panel is located on the front of Emix Tank. From top to bottom we can see:
1...5: GREEN LED: they indicate the water tempera- ture, both in the confi guration menu (desired temperature) and in the operation menu (actual temperature).
6 BLUE LED: It indicates the activation of the elec- trical heaters. Fixed: one or more activated heaters. Flashing: BOOSTER mode selected.
7 YELLOW LED: it indicates the status of the anti- legionella cycle. Fixed: active cycle. Flashing: active cycle, but not closed.
8 RED LED: it indicates that the unit is in stand by. 9 BUTTON for confi guration of operation settings.
10 RECEIVER of infrared signal from the remote control (at the moment the use of the IR signal is reserved for factory procedures).

°C LED 1 LED 2 LED 3 LED 4 LED 5 40 F 45 50 F 55 60 F 65 70 F 75 80 F 85
LED OFF
F Flashing LED

When Emix Tank unit is correctly connected and electrically powered the RED LED is ON (stand by).
Power ON / OFF of Emix Tank To switch on Emix Tank, push and hold the BUTTON for about 4 seconds until the RED LED turns off and the GREEN LEDs of water temperature light up. Emix Tank unit is designed to be always ON. To switch off Emix Tank, push and hold the BUTTON for about 4 seconds until the GREEN LEDs turn off and only the RED LED stays on. At this point release the BUTTON. Once turned on, Emix Tank unit displays the temperature inside the tank.
Desired temperature setting (setpoint) Press and quickly release repeatedly the BUTTON until the led corresponding to the desired temperature lights up (see table). After 5 seconds without any operation, Emix Tank exits the desired temperature setting procedure and begins to display the water temperature in the tank.
Super Booster mode activation When the Super Booster mode is activated, all the electrical heaters will be activated at the same time, together with the heat pump. When the setpoint is reached, all electrical heaters are switched off and the Super Booster mode is automatically turned off. To activate the Super Booster mode, press and hold the BUTTON until the BLUE LED lights up. At this point release BUTTON. 3 consecutive beeps confi rm the setting.
To deactivate the Super Booster mode, press and hold the BUTTON until the GREEN LEDs turn off and the BLUE LED lights up. At this point release BUTTON. 3 consecutive beeps confi rm the deactivation.
When Emix Tank is on, you can change the setting of some parameters. To enter the confi guration menu, press and hold the BUTTON until the BLUE, YELLOW and RED LEDs light up contem- porary. At this point release the BUTTON. After 5 seconds without any operation, Emix Tank exits the confi guration procedure and returns to the previous menu.
Booster mode setting The use of electrical heating elements installed in the storage tank allows you to heat the cold water faster and to reach the desired water temperature even in conditions of very low external temperatures. When you activate the Booster mode, the software will automatically handle the electrical heaters. If after 120‘ from start up of the system the water setpoint is not reached, the fi rst electrical element is automatically activated. The second element will be activated after 120‘ following the course of the water temperature, until reaching the setpoint. To activate / deactivate the Booster mode, enter the confi guration menu, then quickly press the BUTTON until the only BLUE LED is fl ashing. Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more. 3 consecutive beeps confi rm the setting. If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.

Antilegionella cycle setting To activate / deactivate the Antilegionella cycle, enter the confi guration menu, then quickly press the BUTTON until the only YELLOW LED is fl ashing. Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more. 3 consecutive beeps confi rm the setting. If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
EG Setpoint limit setting with Heat Pump It is possible to set the maximum achievable setpoint only with the Heat Pump. This limit can be set to 50°C or 58°C. To change the setting, enter the confi guration menu, then quickly press the BUTTON until the BLUE and YELLOW LEDs are fl ashing. Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more. 3 consecutive beeps confi rm the setting. If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
For details on the operation of the Antilegionella cycle, see section “ANTILEGIONELLA CYCLE”.
Temperature delta setting for restart of the heat pump When the water temperature reaches the set value or the maximum achievable value with the heat pump alone (in the case of Emix Tank operation without other indoor units), the heat pump switches off and starts up again only when the water temperature drops below the desired temperature of a certain value (delta). You can change the startup delta of the heat pump by setting it to 5°C or 10°C. To change the set value, enter the confi guration menu, then quickly press the BUTTON until the BLUE and RED LEDs are fl ashing. Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more. 3 consecutive beeps confi rm the setting. If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
Stratifi cation sensor selection Emix Tank measures the water temperature in the tank through one of the two stratifi cation sensors. It is possible to select which of the two sensors is read for the measurement. To change the sensor, enter the confi guration menu, then quickly press the BUTTON until the YELLOW and RED LEDs are fl ashing. Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more. 3 consecutive beeps confi rm the setting. If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
Reset of the factory settings To reset all the factory settings, enter the confi guration menu, then quickly press the BUTTON until the BLUE, YELLOW and RED LEDs are fl ashing. Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more. 3 consecutive beeps confi rm the reset of factory settings. If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.

In addition to the already described modes in the section “EMIX TANK CONFIGURATION”, Emix Tank software can auto- matically manage electrical back up heaters under certain conditions. This mean that these operation modes are not to be set and that can not be deactivated. They are: - Antifreeze mode - Cold draft prevention mode - Electrical water heater mode (in case heat pump is not active) - Antilegionella cycle
Electrical back up heater management – Antifreeze mode If water temperature inside the tank is lower than 5° C, all electrical elements are switched on until the water temperature reaches 10° C.
Electrical back up heater management – Cold draft prevention mode When one or more indoor units are in cold draft prevention mode and compressor is operating since 20’, one by one electrical element are switched on every 20’; they will be switched off one by one when no indoor unit will be any more in Cold draft prevention mode.
Electrical back up heater management – Electric water heater mode If the outdoor unit is stopped for maintenance, Emix Tank will control automatically the electrical heater elements located inside the tank, exactly like any electrical water heater. In this case, if the water temperature is lower than the desired temperature for more than 10’, all the electrical heaters will switch on up to the reaching of the setpoint. The end user can switch off Emix Tank if he does not want to utilise this option.
Electrical back up heater management – Antilegionella cycle During the Antilegionella cycle, one or more electrical heaters may be automatically switched on. See section “ANTILE- GIONELLA CYCLE”.
Legionella is a bacteria that under certain conditions can be present in any water system. The proliferation of this bacteria depends on many factors and it fi nds the best conditions to survive between 20ºC to 45ºC. That’s why, even though each Country has a different local regulation about Legionella prevention, all of them re- quire to heat water over than 50ºC.
If within 72 hours (3 days) none of the above conditions have been satisfi ed, the cycle is activated. During the cycle the YELLOW LED lights up. It is possible that the electrical heaters are activated during anti legionella cycle. During the cycle, by water temperature trend analysis, if the software understands that there is not enough energy us- ing only the heat pump, the fi rst electrical heater will be switched on automatically. The second electrical heater will be switched on after 120’ depending on the water temperature trend up to reach the necessary conditions to close the cy- cle. If there is a fl ow switch connected, the cycle time will be reduced according to the amount of fresh water introduced into the tank.
If after 8 hours none of the above conditions occurred, the cycle will continue, but the YELLOW LED will begin fl ashing with low frequency to alert the end user. NOTE: The antilegionella cycle is fundamental for the health of people; it is normally completed due to thermodynamic energy, however, we can not exclude that in unfavorable atmospheric conditions, the heat pump is unable to complete by itself the cycle. For this reason it is obligatory to use the heater / the heaters. In case you disconnect the electrical heat- ers, under certain operating conditions, it may happen that the legionella cycle will not be closed, a condition for which our company does not assume any responsibility.


Error Cause LED BLUE YELLOW RED 1 Error on outdoor unit F 3 Communication error with outdoor unit F F F 4 Sensor REFRIGERANT OUT damaged or disconnected
5 Sensor H2O IN damaged or disconnected F F 6 Sensor H2O OUT damaged or disconnected F 8 Electrical heaters not set F 9 Reversed refrigerant tubes error F 10 Sensor REFRIGERANT IN damaged or disconnected
11 Tank sensor (1/3) damaged or disconnected F 12 Tank sensor (2/3) damaged or disconnected F
LED OFF
CARE AND MAINTENANCE
F flashing LED

WIRING DIAGRAM - SCHEMA ELETTRICO - SCHÉMA ÉLECTRIQUE - SCHALTPLAN - ESQUEMA ELÉCTRICO - ESQUEMA ELÉTRICO - ΔΙΑΓΡΑΜΜΑ ΣΥΝΔΕΣΜΟΛΟΓΙΑΣ - ELSCHEMA


Via Alfeno Varo, 35 - 25020 Alfianello - BS - Italy
Tel. +39 0331 755111 - Fax +39 0331 755501
Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| 1 | Error on outdoor unit | p.27 | |
| 3 | Communication error with outdoor unit | p.27 | |
| 4 | Sensor REFRIGERANT OUT damaged or disconnected | p.27 | |
| 5 | Sensor H2O IN damaged or disconnected | p.27 | |
| 6 | Sensor H2O OUT damaged or disconnected | p.27 | |
| 8 | Electrical heaters not set | p.27 | |
| 9 | Reversed refrigerant tubes error | p.27 | |
| 10 | Sensor REFRIGERANT IN damaged or disconnected | p.27 | |
| 11 | Tank sensor (1/3) damaged or disconnected | p.27 | |
| 12 | Tank sensor (2/3) damaged or disconnected | p.27 |