Radio room temperature sensor operation and installation

The device is intended for use in the domestic environment. It can be safely operated by unincorporated persons. In a non-domestic environment, e.g. B. in the small business sector, it may also be used provided that its use is carried out in an identical manner.
WARNING INJURY The device may be used by children aged 8 years and older, as well as those with reduced physical, sensory or mental abilities or lack of experience and knowledge if they are supervised or have been instructed on the safe use of the device and understand the resulting dangers. Children are not allowed to play with the device. Reiniction and user maintenance must not be performed by Kindern without supervision.
To ensure that your device arrives undamaged, we have carefully packaged it. Please help to protect the environment and dispose of the packaging material of the device properly. Together with the wholesalers and specialist trade / specialised trade in Germany, we are participating in an effective take-back and disposal concept for environmentally friendly packaging processing.
Leave the transport packaging to the tradesman or specialist retailer.
Disposal of sales packaging via one of the dual systems in Germany.
Equipment disposal services The devices marked with this symbol must not be disposed of together with the household waste.
As a manufacturer, we ensure environmentally sound treatment and recycling of the waste equipment within the framework of product responsibility. Further information on collection and disposal can be obtained via your municipality or specialist craftsman / dealer.
Already when developing new devices, we pay attention to a high recyclability of the materials.
The take-back system achieves high recycling rates of materials in order to relieve landfill and the environment. Together, we are making an important contribution to environmental protection.
Disposal of this device professionally and properly in accordance with the local regulations and laws.

Instructions for use
Sunday program will leave the program input automatically, but can also be terminated at any time by direct dial-up button. If no button actuation takes place for more than 2 minutes, the function is terminated automatically. Not with confirmed inputs will not be accepted. After the program input has ended, the display changes again to the previous operating view. Entry: Press the direct dial button and enter ECO temperature (ECO in display). Depending on the adjustment setting, the ECO temperatures are used as absolute values in a range of 5 ... 29°C (factory setting 17°C) or relative to the setpoint value – temperature reduction in heating mode: -1°... -6°, OFF heating and temperature increase in cooling mode: 1°... 6°, cooling OFF (factory setting Heating −2°, Cooling 2°). After confirmation with , the time is entered (in the display). First enter the hours, and then enter the minutes. After confirmation with , the date is entered (D in display). First enter the year and confirm with. Then enter the month and day. After confirmation with , the daily programs are entered. For this purpose, the day of the week is first selected. In the display, the 1 for Monday flashes. The selection of another day of the week is made with and . After confirmation of the day of the week with , setting of the switching segments ("rider") takes place, starting at 0.00 o'clock. In addition to the setting time, the current position at which the tab can be set flashes. With each pressure of the button, a 1⁄4 hour rider is set for comfort temperature; with every pressure of this key one half an hour further jumps without setting a switching segment. If pressed or long, the scroll function becomes active. In the case of incorrect inputs, a reset and new entry is possible by exceeding the 0.00 clock mark without leaving the currently selected day. After confirmation with , the next day of the week flashes for selection. After selecting the next day with , the copy function comes into effect and the program just entered for the previous day is pre-laid. This program can be adopted or another programme entered. After confirmation with flashes the next day of the week for dialing, etc. The copy function is interrupted with the selection of Sunday evening and the Saturday program for Sunday offered again. If the radio room temperature sensor has been adapted to a heating/cooling system in adjustment mode, the input is extended by daily programs for the cooling operating mode. For further adjustments see point 3. Adjustment functions.
1. Instructions for operation 2. Function Direct dial buttons , ,, , 2.1 Program input 2.2 Display heating system, air conditioning system or cooling system 2.3 Operating modes Automatic operation , Comfort and Energy saving ECO 2.4 On/off function 2.5 Holiday function 2.6 Information function 2.7 Party function 3. Adjustment functions J.1 ... J.6 3.1 J.1, Learning function 3.2 J.2 Log-off function 3.3 J.3 Display during operation – time, temperature, alternating time/temperature 3.4 J.4 Program display by means of switching segments (“Rair Ring”) On/Off 3.5 J.5 Child Restraint on/Out 3.6 J.7 Automatic summer/winter time changeover On/OFF 4. Reset function, 5. Battery idle state indicator 6 . Light and display indicators on the radio room temperature sensor Subsequent installation instructions
If the sensor has been adapted to a heating system (factory setting), all 3 operating modes, such as comfort, ECO and automatic operation, permanently display the heating symbol. If the sensor has been adapted to a cooling system, the cooling symbol is permanently displayed. In the air conditioning system (heating and cooling) both symbols are displayed in comfort and ECO operation. In automatic operation, the program display with the corresponding symbol changes every 15 seconds between the heating and cooling programs. If the program display (crest ring) is deactivated in adjustment mode, both symbols are also activated during automatic operation.
Permanently displayed.
This function serves to switch the 3 operating modes, automatic operation , comfort operation and energy-efficient ECO. The set operating mode is represented in the display by the switching segments (“rider ring”) known from mechanical switches. Visible switching segments ("riders") indicate the times of comfort operation, missing parts show the times for energy-efficient operation. The operating modes automatic operation and energy-efficient operation are additionally indicated by the clock program symbol and the abbreviation ECO. The comfort operation is represented exclusively by the circumferential rider ring. In the mode of operation, comfort is permanently regulated to the temperature selected by means of the setting button. In the energy-saving mode (ECO) operating mode, the input ECO temperature is regulated. In the operating mode automatic operation, a switch is made automatically between comfort and energy-saving operation.
There are a total of 6 direct dial-up buttons with which the desired function is dialed and left again. Unneeded buttons are deactivated while remaining in a function. For the selection of another function, the currently selected function must first be left again.
The program input serves to set the ECO temperature, time, date and daily programs. Activated, it works on the principle of forced guidance. If a value is confirmed with the key, the display changes to the next input step. During the active function, a P is displayed in the display. In addition, depending on the input step, the function of the value is represented by easily understandable symbols and the value to be entered is displayed in a flashing manner. With confirmation of
If the button is actuated, the control system is switched off. After actuating the button again, it returns to its previous operating mode. In order to distinguish between a switched-off control and empty batteries of the radio room temperature sensor, “OFF” is displayed on the display when the control is switched off.

When the control is switched off, frost protection at 5° C. remains guaranteed. If the valve and pump protection is activated in the adjustment menu, this also remains guaranteed.
3.4 J.4 Program display by means of switching segments ("Riterkranz") On/Off On = On (factory setting) OFF = Off
2.5 Holiday function The holiday function serves to save energy during a longer period of time and heat up in good time to the desired temperature at the return point. If the button is pressed, the date of the following day will be displayed. After setting the return date with , and buttons, the holiday temperature is displayed. Depending on the adjustment input, holiday temperatures are set as absolute values in a range of 5 ... 30°C (factory setting 17°C) or relative to the setpoint value – temperature reduction in heating mode: -1°... -6°, OFF heating and temperature lift in cooling mode: 1°... 6°, cooling OFF (factory setting Heating −2°, Cooling 2°). After confirmation of the holiday temperature with , the holiday function is active and the return date as well as the holiday symbol are displayed. The holiday function can be terminated at any time by the direct dial-up button, or is automatically terminated by 0.00 o'clock of the entered day of return. After the leave function has ended, the regulation will continue with the previous operating mode and associated notification.
3.5 J.5 Child safety on/off The child safety guard serves to protect against accidental adjustment or displacement by unauthorized persons during operation. If the parental control is activated, 3 minutes after the last button press all keys and changes with the temperature setting button are locked and the key icon displayed in the display. In order to activate the keys again, the button must be ca. Press for 10 seconds until the key icon goes out. During the keystroke, the key symbol flashes. 3 minutes after the last press of a button, the keys are automatically locked again. If the desired temperature on the setting button has been adjusted during active key locking, this is valid only after activation of the operating elements. On = OFF = Off (factory setting)
3.6 J.6 Automatic Summer/Winter Time Change On/Off The standardised summer time in the European Union is valid from the last Sunday of March at 2:00 CET until the last Saturday of October at 3:00 CEST (Directive 2000/84/EC of the European Parliament and of the Council). At these appointments, the radio room temperature sensor automatically changes time. For time changes to other dates or regions without a time change, the automatic summer/winter time change can be deactivated. On = On (factory setting) OFF = Off
2.6 Information function The information function serves to display all set values without the possibility of an accidental adjustment. During the active function, a is displayed in the display. After actuation of the key, all set values can be viewed with the keys and buttons. It is not possible to change values intentionally or accidentally. The information function can be terminated at any time by the direct dial-up button or is automatically terminated 2 minutes after the last key press. The control is not influenced by the selection of the information function. After the information function has been terminated, the display switches back to the previous operating view.
4. reset function , The reset function is used to restore the delivery status and sets all input values, for program times, ECO temperature and holiday temperature as well as adjustment settings back to factory settings. The time, date and values entered in the craftsman mode are not reset. As protection against accidental resetting, this function consists of a combination of 2 buttons that must be operated in the following order. First the button and then additionally the key permanently approx. Press 10 seconds until the indicator stops blinking. The delivery state is restored, minus the above mentioned restrictions.
2.7 Party function The party function, regardless of the set program or operating mode, serves to trigger a comfort heating time once from the moment of input. When the button is pressed, the next possible end time of the comfort heating time (party-end) will be displayed. After setting the end time with , and buttons, the party function is in operation. The end time is displayed together with the party symbol until the end of the set comfort heating time. The party function can be terminated at any time by the direct dial-up button or is automatically terminated after reaching the entered end time. After the party function has been terminated, regulation is continued with the previous operating mode and corresponding display.
3. alignment function J.1 ... J.6 The adjustment functions serve to adapt the control system, which is usually one-time, to the individual needs of the user. They are taken from the normal operating surface in favor of simpler operation during operation and are displayed on a separate menu. In order to enter the adjustment mode, first of all the key is pressed and additionally briefly the button. The first adjustment function J. 1 is displayed in the display. With the , and buttons, the desired adjustment function is selected. The settings are also made - if again with the and buttons and must be confirmed. The adjustment function can be terminated at any time by the button or is automatically terminated 2 minutes after the last key press. Not with confirmed inputs will not be accepted. After the adjustment function has been terminated, regulation is continued with the preceding operating mode and the corresponding display. For further adjustment options see point 12. Adjustment functions in craftsman mode.
If the flashing battery idle reading in the display is not noticed early, the lamp on the radio room temperature sensor starts to blink red for 5 seconds per minute. The battery idle condition is indicated by the lamp for at least 7 days, while maintaining control. The battery idle reading does not affect the backlighting battery. However, it is recommended to change the battery of background lighting because of the risk of overlay. After replacing the batteries, there is no need to train again the radio room temperature sensor. The time and date must be re-entered.
Lamp made of: The radio room temperature sensor works correctly. Prerequisite, the batteries are inserted correctly. Lamp flashes red: The batteries are empty and must be changed, the control is active during flashing and works correctly. See point 5. Battery blank indicator and point 10. putting into service. During the learning process (cf. 3.1 and 11.) the lamp also flashes red. Lamp is continuously red: During the log-off process (cf. 3.2) the lamp is permanently red. Display display: Fbr sensor breakage. The device must be inspected at the factory. Display display: FSch sensing short circuit. The device must be inspected at the factory. Display display: This symbol appears only briefly (1 second) and indicates a radio transmission to the radio temperature controller. Display display: The battery is discharged and needs to be replaced. Display: flashing switching segments (heating devices) Blinking switching segments characterize the advanced switchover time from ECO- to comfort operation during automatic mode. The advanced switchover time is determined by the radio room temperature sensor itself when the self-learning function was activated in craftsman mode. (cf.) Point 12.3. Display display: L Learning mode (see point 3.1 and point 11.) Display indicator: -L Log-off mode (see point 3.2)
3.1 J.1 Learning function This learning process is required in addition to the teaching process at start-up, in order to teach the radio room temperature sensor (transmitter) to several radio temperature controllers (receiver), without having to enter the time repeatedly by removing the batteries multiple times. After dialling with the button, a flashing L is displayed. Pressing the button again triggers the 10-second learning process. During the 10 seconds, the lamp of the radio room temperature sensor flashes red. After the learning process, J.1 is again displayed in order to teach the radio room temperature sensor to a further radio temperature controller. For the implementation of the learning process, note point 11, sub-item: Learning Process 1 and 2.
3.2 J.2 Log-off function This function serves to log off the radio room temperature sensor (Sen- der) from a radio temperature controller (receiver). After election with the
The button is flashing -L. Pressing the button again triggers the 10-second logout process. During the 10 seconds, the lamp of the radio room temperature sensor lights up red. In order to log off the radio room temperature sensor, it is necessary to press the learning button on the radio temperature controller during this time.
3.3 J.3 Display during operation – time, temperature, alternating time/temperature A1 = permanent display of time (factory setting) A2 = permanent indication of temperature A3=changing display time/temperature (display 5 seconds each)

After the batteries have been inserted, the radio room temperature sensor first performs a self-test for several seconds in which all display symbols appear. After the self-test and subsequent display of the software version, the radio room temperature sensor automatically switches to the
This device forms a control unit together with an appropriate radio temperature controller (receiver). Therefore, the initial installation must be carried out by an electrical specialist, taking into account the applicable safety regulations. Attention! Operation in the vicinity of devices that do not comply with EMC guidelines can lead to an influence on device function. Settings or changes to the adjustments in hand-operated mode, can influence the control and may also only be made by a suitably qualified specialist. After installation, the operator shall be instructed by the installer to operate and operate the control system. The operator's accessories must be kept in a freely accessible place for operators and maintenance personnel.
Learn mode, in the display L is shown. After learning (see point 11.), the flashing display “00.00” will show a request to enter the time and date. If the learning process is not to be carried out at this time, the learning mode can be aborted by pressing the button and immediately changed for entering the time of day and date. If no time and date is entered, the operating mode automatic operation shall be activated upon initial start-up after 2 minutes. Acknowledgement! If no time and date is entered, then the time starts at 00.00 hrs and the reheating times do not correspond to the actual daytime. The setting of the time and date after activation of automatic operation is described in point 2.1 Program input.

When the batteries are inserted
Medium battery for background irrigation
Temperature control system – heating/air conditioning/cooling system 11. The learning function 12 . Adjustment function J.7 . . J.12 “Craftsman mode” 12.1 J.7-temperature unit °C/°F 12.2 J.8 Valve and pump protection On/Of 12.3 J.9 Self-learning function On/Out of 12.4 J.10 ECO temperature input relative/absolute 12.5 J.11
10.1 Adaptation of the display and input possibilities to the temperature control system: heating system / air conditioning system / cooling system
The radio room temperature sensor must be adapted in adjustment step J.11 to the heating-only (factory setting), cooling-onLY or heating-or-cooling system. The adaptation is necessary in order to activate or adjust the display and input possibilities associated with the temperature control system. not applicable to deactivate (dynamic menu). Attention! If the sensor is not adapted to the temperature control system, the energy saving function ECO will not be executed in the non-activated mode “cooling” or “heating”.
Temperature control system – heating/air conditioning/cooling system 12.6 J.12 correction (offset) of the actual value acquisition to room temperature
± 5K (indicator ± 5°) 13. Functional and assignment control of the radio link 14 . Accessories 15. Mounting 16 Technical data 17. Dimensional drawings
With the learning function, a radio room temperature sensor (transmitter) is assigned to the respective radio temperature controller (receiver). There are two ways to start the learning process of the radio room temperature sensor. Immediately after insertion of the batteries during commissioning point 10. or as described in point 3.1, in adjustment mode. Teaching process after insertion of the batteries: After the batteries are inserted, an L for learning mode flashes after self-testing and display of the software version for 2 minutes. The radio temperature controller is now switched to the learning mode and subsequently the key on the radio room temperature sensor is briefly pressed. The radio room temperature sensor sends the learning identifier for 10 seconds, and then switches to entering the time. 1.) Switch radio room temperature sensor into learning mode and briefly press the learn button on the radio temperature controller The lamp on the wireless speed rating control flashes red for a maximum of 30 seconds. If no transmitter is learned during this time, the lamp stops flashing and changes back to its initial state. Press the button on the radio room temperature sensor for a short time The lamp on the wireless room temperature detector flashes for approx. 10 seconds red, the lamp on the radio temperature controller changes from red blinking to green continuous light. The radio link is established. After correct learning, the lamp lights up on the radio temperature controller for approx. 1 hour green, the regulation is now active. For other indications on the radio temperature control, please note its operating instructions point light indicators. After the radio room temperature sensor has been placed in the space to be controlled, the correct radio connection must again be checked on the radio temperature controller using the green continuous lamp of the lamp. If the radio connection is broken, the lamp lights up after approx. 5 minutes red. 1 hour after learning, the green lamp goes out and thus indicates correct operation.
The description of the following functions can be found in the operating control system for the radio temperature controller. Master-slave control (automatic operation for several rooms with one
Central radio room temperature sensor with clock) Connection loss (radio interruption) Emergency operation in case of connection loss (control for sub-broadband control).
This radio room temperature sensor (transmitter) with time-controlled energy saving function, has been specially developed for the detection of temperature in living, office and hotel spaces and is operated together with one or more radio temperature controllers (receiver). The overall unit comprising radio room temperature sensor and radio temperature controller thus serves for individual room temperature control. Radio room temperature regulation is used primarily in the renovation sector, for heating system expansions where complex tear-up and cleaning work for electrical line installation should be avoided or in modern office complexes where flexibility of spatial design is paramount. For other applications which are not foreseen by the manufacturer, the safety regulations applicable there must be observed.
The radio room temperature sensor measures the room temperature with an internally located probe and sends this together with the desired temperature to the learned radio temperature controller. It is possible to train the radio room temperature sensor (transmitter) on any number of radio temperature controllers (receiver). Thus, e.g. a plurality of electric heating elements/plates or hot water valves are controlled via a sensor. The transmission range of the radio room temperature sensor is to a large extent dependent on spatial conditions. The range is thus reduced by reinforced walls and ceilings as well as metal housing.
Attention! In these adjustment functions, control settings are specified which may only be carried out by a qualified heater or electrical specialist. Settings in crafter mode cannot be reset by the Reset function, but must be set deliberately. Thus, a clear proof of the settings by one person is given. The craftsman mode is activated from the normal adjustment mode (point 3.). For this purpose, the display J.6 must be shown. The key is now first pressed and the button briefly pressed, and the display shows the first adjustment function of craftsman mode J.7. After activation of the craftsman mode, all 12 adjustment functions can be selected with the and buttons. The craftsman mode can be terminated at any time by the button, or is automatically terminated 2 minutes after the last key press. Not with confirmed inputs will not be accepted. After the hand-worker mode has been terminated, the display changes again to the previous operating view.
In the delivery state, the radio room temperature sensor is not operated. Operational readiness is only established by inserting the batteries and teaching the radio room temperature sensor (transmitter) to the radio temperature controller (receiver) (here on point 11). Learning function. When inserting the batteries, care must be taken to ensure correct polarity. In order to achieve the maximum running time, only new batteries of the specified design and equivalent quality of original batteries may be used. This device can be operated with a third battery for the backlighting. This is placed centrally between the two batteries necessary for temperature regulation. The battery life, of the two batteries required for temperature rating control, is thus independent from background illumination.
Observe the polishing! · + + +

14 Accessories
The temperature unit switchover is indicated directly as °C or °F. (factory setting °C)
12.2 J.8 Valve and pump protection on/off
The radio room temperature sensor is advantageously mounted with two-sided adhesive tape or, in the case of walls covered by paper, on an inner wall opposite to the heating device at a height of 1.50 m. The substrate shall be dry, dust- and grease free, level and load bearing. Table, shelf or cabinet locations are not suitable due to unfavorable air flows and influence of external heat sources (e.g. Persons, equipment, canisters, sunlight etc.) not recommended. An adhesive strip is included in the package.
The valve and pump protection serves to prevent the tight corrosion of the valve seat and/or the pump during long downtimes. For hot water heaters, activation of the valve protection is recommended. The radio room temperature sensor sends the signal to all trained receivers or relayers on Monday from 11:00 a.m. Channels, regardless of number and type of other trained radio transmitter. The radio temperature controller (receiver) then activates the valve and pump once for 5 hours. 12 minutes. On = OFF = Off (factory setting)
The self-learning function serves for the independent attainment of the comfort temperature at the set time. The advanced switchover time from ECO to comfort temperature is automatically set and indicated by blinking switching segments (“heating devices”). The heating time varies depending on the heat output and outside temperature. On = OFF = Off (factory setting)

The adjustment for absolute ECO temperature input can only be performed if the display and input possibilities in the adjustment step J 11 have been adapted to a heating system. In factory setting, the ECO temperature becomes relative, i.e. as a function of the desired value, −1° ... -6°, OFF or for cold fall 1° ... 6°, OFF. For the relative input of ECO temperature, a 1 is displayed for absolute input a 2.
12.5 J.11 Adaptation of the display and input possibilities to the temperature control system: heating system / air conditioning system / cooling system With this adjustment step, the display and input possibilities are adapted to the existing temperature control system (dynamic menu). For example, it is not possible to enter an ECO temperature or time for cooling operation when adapting to a heating system. At the factory, the display and input possibilities are adapted to a heating system. In the case of a cooling system or heating/cooling (air conditioning) system, the display and input options for the clock transmitter must be adapted. Displayed in the display are for selection “Heating system” H and , for selection "Cooling system" C and for selection of "Climate control system" HC as well.
Supply voltage: battery 2 or 3 Micro AAA, Attention! No batteries use battery life: approx. 3 years. Very frequent button actuation reduces the battery life of the backlight. Attention! Change the batteries every 5 years at the latest! Temperature sensor: Internal setting range: 5 ... 30° C. Display range: 0 ... 45° C. Resolution: 0.1 K Sensor tolerance: approx. ±1K Adjustment scale: °C Scale Transmission frequency 868,3 MHz Range: 150 m line of sight, up to 30 m ambient temperature allowed in buildings: –10 ... +50° C admissible storage temperature: – 10 ... +50 C permissible humidity: max. 95%rH, non-dewing housing: Berlin 3000 housing material and paint: ABS plastic, pure white (similar to RAL9010) protection class: III protection class; IP30 assembly type: adhesive strip or wall holder
12.6 J.12 Correction (offset) of the actual value acquisition to room temperature ±5K (indication ±5°). The correction serves to adapt the actual value acquisition to the room temperature (target: nominal value scale/actual value display=room temperature). The adaptation is necessary where a constantly constant thermal influence of the radio room temperature sensor by an external heat or cold source cannot be prevented. If the radio room temperature sensor is influenced, for example by a heat source, a cooler room temperature will be established than that set with the desired value button. The correction of the actual value acquisition can be carried out in 0.1K steps. Example of external heating: Assumption: At a displayed and set target temperature of 22° C., the result is room temperature 20° C. In order to achieve a room temperature of 22°C, with simultaneous setpoint setting of 22 °C, the difference must be subtracted from 2K by correction of actual value acquisition, and the correction value –2.0°. The radio room temperature sensor corrects the measured actual value by –2K, which leads to a room temperature increase to 22°C nominal value scale/actual reading = room temperature. Example of external cooling: Assumption: At a displayed and set target temperature of 22° C., the result is a room temperature 24° C In order to achieve a room temperature of 22° C., with simultaneous setpoint value adjustment of 22 ° C. the difference of 2K must be added together with correction of actual-value detection, correction value +2.0°. The radio room temperature sensor corrects the measured actual value by +2 K, which leads to a lowering of the room temperature to 22° C. Setpoint scale/actual value display=room temperature.
This device, when used as intended, meets the basic requirements
Requirements and other relevant requirements
provisions of Directive 1999/5/EC.
13. Functional Radio link allocation check
This function serves for subsequent monitoring of the correct allocation of radio room temperature sensors to various radio heating controllers. Confusions are thus easily recognized even at a later time. Triggering the learning process on a radio room temperature sensor (transmitter) The lamp at the radio room pressure sensor flashes red during this time. If the lamp on the radio heating controller (receiver) starts to flash green, the radio room temperature sensor is trained and connected.
Adaptor plate as wall holder

Accessibility Should a disturbance occur to one of our products, we will naturally be at your side with advice and deeds. AEG Haustechnik | Customer service | Fürstenberger Straße 77 | 37603 Holzminden Tel. 05531 702-111 | Fax 05530 702-95890 | [email protected] Further addresses are listed on the last page. Our customer service can be reached by phone around the clock, also on Saturdays and Sundays as well as public holidays. Customer service assignments are made during our business hours (from 7.30 to 16.30, Fridays until 14.00). As a special service we offer customer support assignments until 10 pm. For this special service as well as customer support operations on Sams, Sunday and public holidays higher prices are charged. Guarantee terms These guarantee conditions regulate additional warranty services from us to the end customer. They are in addition to the legal warranty claims of the customer. The legal warranty claims against the other contractual partners are not affected. These warranty terms apply only to devices purchased as new by the end customer in Germany. A guarantee contract shall not be concluded if the end customer purchases a used device or a new device from another end user. Content and scope of the guarantee The warranty is provided if a manufacturing and/or material defect occurs on our devices within the guarantee period. However, the warranty does not include services for such equipment in which faults, damage or defects due to calcification, chemical or electrochemical action, erroneous installation and/or installation, improper alignment or operation of the system and/or incorrect use; use occur. Likewise excluded are services due to defective or omitted maintenance, weather influences or other natural phenomena. The warranty expires if repairs, intervention or modifications have been made to the device by persons not authorised by us. The guarantee covers the careful examination of the device, first determining whether a warranty claim exists. In the event of a guarantee, we alone decide on how to correct the error. We are free to have a repair of the device carried out or carry it out ourselves. Any replaced parts become our property. For the duration and range of the warranty, we cover all material and assembly costs. Insofar as the customer has received services due to the case of a guarantee on account of legal warranty claims against other contractual partners, we shall not be obliged to provide any service. If a guarantee is provided, we do not assume liability for the damage of an equipment by theft, fire, riot or. . Causes. In addition to the above-proposed guarantee services, the end customer cannot assert any claims under this warranty for indirect damage or consequential damage caused by the device, especially compensation of damage incurred outside the device. Legal claims of the customer towards us or against third parties remain unaffected.
Guarantee period For appliances used in private households, the guarantee period is 24 months; otherwise (e.g. B. if the equipment is used in commercial, craft or industrial enterprises, the warranty period shall be 12 months. The warranty period for each device begins with the delivery of the device to the customer who uses it for the first time. Guarantees shall not lead to an extension of the duration of the guarantee. The guarantee provided will not set in motion a new warranty period. This applies to all warranty services provided, in particular for any installed spare parts or replacement delivery of a new device. Use of the guarantee Warranty claims must be registered with us before the expiry of the warranty period, within two weeks after the defect has been detected. The error, the device and at time of detection shall be reported. As proof of guarantee, the invoice or another dated proof of purchase must be attached. If the aforementioned information or sub-objections are missing, there is no guarantee claim. Guarantees for equipment purchased in Germany but used outside of Germany We are not obliged to provide guarantee services outside the Federal Republic of Germany. In the event of malfunctions in a device used abroad, this must be sent to customer service in Germany at the risk and expense of the customer. The return is also at the risk and expense of the customer. Any legal claims of the customer towards us or against third parties remain unaffected in this case. Devices purchased outside Germany For devices purchased outside Germany, this guarantee does not apply. The respective legal regulations and, if applicable, the delivery conditions of the national company or the importer.

Sales centre
Australia STIEBEL ELTRON Australia Pty. Ltd 6 Prohasky Street Port Melbourne VIC 3207 Tel. 03 9645-1833 Fax 03 9644-4366
EHT Haustechnik GmbH Brand distribution AEG Gutenstetter Straße 10 90449 Nuremberg [email protected] www.aeg-haustechnik.de Tel. 0911 9656-250 Fax 0911 9656-444
Austria STIEBEL ELTRON Ges.m.b.H Eferdinger Str. 73 4600 Wels Tel. 07242 47367-0 Fax 07242, 47367-42
Holzminden Fürstenberger Str. 77 37603 Wood mints Letter address 37601 Timber mint
Belgium STIEBEL ELTRON bvba/sprl 't Hofveld 6 - D1 1702 Groot-Bijgaarden Tel. 02 42322-22 Fax 02 42322-12
The customer service and spare parts sale is available in the period from Monday to Thursday, between 7.15 a.m. and 6.00 p.m and Fridays between 7.10 a. m. and 5.00 pm. Reachable by fax number:
Czech Republic STIEBEL ELTRON spol. s r.o. K Hájům 946 155 00 Praha 5 - Stodůlky Tel. 251116-111 Fax 235512-122
Hungary STIEBEL ELTRON KFT. Gyár u. 2 2040 Budaörs tel. 01 250-6055 Fax 01 368-8097
Netherlands STIEBEL ELTRON Nederland BV Daviottenweg 36 5222 BH 's-Hertogenbosch Tel. 073 623-0000 Fax 073 723-1141
Poland STIEBEL ELTRON Polska Sp. c O.O. ul. Działkowa 2 02-234 Warszawa Tel. 022 60920-30 Fax 02260920 - 29
Russia STIEBEL ELTRON LLC RUSSIA Urzhumskaya street 4, building 2 129343 Moscow Tel. 0495 7753889 Fax 0495 675 3887
Switzerland STIEBEL ELTRON AG Industrie West Gass 8 5242 Lupfig Tel. 056 4640-500 Fax 0564640-501
www.aeg-haustechnik.de
© EHT Haustechnik
A 318978-38650-1513
B 318973-38650-9038
4<AMHCMO=bijhih>
AEG is a registered trademark used under license from AB Electrolux (publ).
Mistake and technical changes reserved! Subject to errors and technical changes! | Sous réserve d’erreurs et de modification techniques! | Onder voorbehoud van vergessingen and technical wijzigingen! Salvo error o modificación técnica! | Rätt till misstag och tekniska ändringar förbehålls! | Excepto erro ou alteração técnica | Zastrzeżone zmiany techniczne i ewentualne błędy | Omyly a technické změny jsou vyhrazeny! A muszaki változtatások és tévedések jogát fenntartjuk! | Отсутствие ошибок не гарантируется. Возможны технические изменения.’ Chyby a technické zmeny sú vyhradené! 1505