Radio room temperature sensor operation and installation
Wireless room temperature sensor Operation and Installation

ENGLISH
The device is intended for use in the home environment. It can be safely operated by unincorporated persons. In a non-domestic environment, e.g. B. in the small business sector, it can also be used provided that use is made in the same way.
This appliance is designed for domestic use. It can be used safely by untrained persons. The appliance can also be used in a non-domestic environment, e.g. In a small business, as long as it is used in the same way.
WARNING Injury The appliance may be used by children aged 8 and up and persons with reduced physical, sensory or mental capabilities or a lack of experience provided that they are supervised or have been instruct- ed on how to use the appliance safely and have un- derstand the resulting risks. Children must never play with the appliance. Children must never clean the appliance or perform user maintenance unless they are supervised.
WARNING INJURY The device may be used by children aged 8 years and older, as well as those with reduced physical, sensory or mental abilities or lack of experience and knowledge if they are supervised or have been instructed on the safe use of the device and understand the resulting dangers. Children are not allowed to play with the device. Reiniction and user maintenance must not be performed by Kindern without supervision.
The warranty conditions of our German companies do not apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products, it is increasingly the case that warranties can only be issued by those subsidiums. Such warranties are only granted if the subsidiary has issued its own terms of warranty. No other warranty will be granted.
To ensure that your device arrives undamaged, we have carefully packaged it. Please help to protect the environment and dispose of the packaging material of the device properly. Together with the wholesalers and specialist trade / specialised trade in Germany, we are participating in an effective take-back and disposal concept for environmentally friendly packaging processing.
We shall not provide any warranty for appliances acquired in countries where we have no subsidiary to sell our products. This will not affect warranties issued by any importers.
Leave the transport packaging to the tradesman or specialist retailer.
We would ask you to help protect the environment. After use, dispose of the various materials in accordance with national regulations.
Disposal of sales packaging via one of the dual systems in Germany.
Equipment disposal services The devices marked with this symbol must not be disposed of together with the household waste.
As a manufacturer, we ensure environmentally sound treatment and recycling of the waste equipment within the framework of product responsibility. Further information on collection and disposal can be obtained via your municipality or specialist craftsman / dealer.
Already when developing new devices, we pay attention to a high recyclability of the materials.
The take-back system achieves high recycling rates of materials in order to relieve landfill and the environment. Together, we are making an important contribution to environmental protection.
Disposal of this device professionally and properly in accordance with the local regulations and laws.

Radio room temperature sensor with setpoint adjuster and switch
“Comfort/ECO” Radio-controlled room temperature sensor with set point setter and
“comfort/ECO” switch
GB
This device forms a control unit together with an appropriate radio temperature controller (receiver). Therefore, the initial installation must be carried out by an electrical specialist taking into account the valid safety regulations. Attention! Operation in the vicinity of devices that do not comply with EMC guidelines can lead to an influence on device function. After installation, the operator shall be instructed by the executing installer to operate and operate the control system. The operating instructions must be kept in a freely accessible place for operators and maintenance personnel.
This sensor with its radio-controlled temperature controller (receiver) forms a control unit. That is why initial installation is to be undertaken by a qualified electrician with consideration given to the safety regulations in force. Caution! Operations conducted near equipment not complying with EMV guidelines can impair sensor function. Following installation, the firm carrying out this work is to instruct the operator in control functioning and operation. The operating instructions are to be kept where operating and maintenance staff have access to them at all times.
Overview
01.1 Brief guide 02.1 Application 03.1 Function generally 04.1 Start-up 04.1 Range constraint of the temperature setting 05.1 Learning function 06.1 Logging off function (erasing function) 07.1 Battery blank display 08.1 Malfunction at radio room temperature sensor 09.1 Light indicators on radio room pressure sensor 10.1 Functional and assignment control of radio connection 11.1 Mounting 12.1 Technical data 13.1 Installation information for battery replacement 14.1 Installation instructions 15.1 Dimension drawing
01.1 Short instruction 02.1 Application 03.1 General functioning 04.1 Commissioning 05.1 Range limitation of the temperature setting 05.1 Learn function 06.1 Logging-off function (delete function) 07.1 “Battery empty” indication 08.1 Functional fault at the radio-controlled room temperature sensor 09.1 LED display at the Radio-Controlled Room temperature sensor 10.1 Function and assignment check of the radio contact 11.1 Mounting 12.1 Technical data 13.1 Mounting information for battery replacement 14.1 Installation information 15.1 Dimensioned drawing
The description of the following functions can be found in the operating manual for the radio temperature controller ➞Master-Slave control (clock program control for several rooms with
A description of the following functions is in the operating instructions of the radio-controlled temperature controller ➞Master/slave control (time-based program control for several rooms with
a central radio room temperature sensor with clock) ➞ connection loss (radio interruption), ✞ emergency operation function in the event of connection loss, control in the case of radio interruption
a central radio-controlled room temperature sensor with timer) ➞Contact loss (radio signal interruption) Ø➟Emergency running function given loss of contact (control in case of radio
signal interruption ➞Functional check on radio contact
1. Short instruction
1.) Insert batteries on the radio room temperature sensor and switch mains voltage to the radio temperature controller 2.) Short press learning button on the wireless temperature controller ➞Lamp flashes red 3. Pressing and holding down on the mobile room temperature detector until lamp on the device flashes green 4.
Insert batteries at radio-controlled room temperature sensor and switch on mains voltage at the radio-Controlled temperature controller. Briefly depress learn key at the radio-controlled temperature controller ➞ lamp flashes red. Press learn key at the radio-controlled room temperature sensor and keep depressed until lamp at the Radio-Controlled Temperature Controller flashes green. Mount radio-controlled room temperature sensor at a suitable place, set the desired temperature – the control system is now activated.
2. Application
This radio room temperature sensor (transmitter) has been developed specifically for the temperature detection in living, office and hotel spaces and is operated together with one or more radio temperature controllers (receiver). The unit comprising radio room temperature sensor and radio temperature controller thus serves for individual room temperature control. Radio room temperature control is used primarily in the renovation area or heating system extensions, where complex tear-up and cleaning work for electrical line installation should be avoided, or in modern office complexes, where flexibility of spatial design is paramount. For other applications which are not foreseen by the manufacturer, the safety regulations applicable there must be observed.
This radio-controlled room temperature sensor (transmitter) has been specially directed for rooms at home, for offices and hotel rooms and is collectively run with one or several radio-Controlled temperature controllers (receivers). The complete unit of radio-controlled room temperature sensor and radio-Controlled temperature controller is for controlling individual room temperatures. The radio-controlled room temperature controller is chiefly used in the building reconstruction sphere or wherever heating systems are to be extended and where the avoidance of costly cutting up and/or plaster work for laying electric cables is important. The same also applies to modern office complexes where emphasis is on interior design flexibility. The valid safety provisions in other fields of use not anticipated by the manufacturer are to be heeded.

3. General functioning
This device measures the room temperature with an internal sensor and sends it to the trained radio temperature controller. If a setpoint value is present, the adjusted temperature setpoint is likewise transmitted. The apparatus has a switch that allows switching between the comfort temperature or ECO temperature modes. In ECO operation, starting from the currently set desired value and in heating mode to a temperature of approximately 1 m/s2. 4K lower temperature controlled. When operating in ECO combined heating and cooling systems, a temperature of approximately 4K is allowed for the refrigeration. Attention! In master-slave operation, the ECO function of the switch automatically changes to “Participation in master-Slave mode”. For this purpose, see the operating instructions of the radio temperature controller "master-slave control". It is possible to train the radio room temperature sensor (transmitter) on any number of radio temperature controllers (receiver). Thus, e.g. a plurality of electric heaters/plates or hot water valves can be controlled by means of a sensor. The transmission range of the radio room temperature sensor is to a large extent dependent on spatial conditions. The range is thus reduced by reinforced walls, ceilings and metal housing.
The internal sensor takes the temperature of the room and transmits it to the trained radio-controlled temperature controller. The adjusted temperature set point is also transmitted. The device has a switch for changing over from com- fort to ECO temperatures and back again. Control under ECO operations pro- ceeds from the currently adjusted set point and under heating operations from a 4K lower temperature. A 4K higher temperature is permitted with cooling under ECO operations in combined heating/cooling systems. Caution! Under master/slave operations, the switch ECO function automatically changes to “Participation in master/Slave operation”. Note here the operating instructions of the radio-controlled temperature controller – “Master/slave control”. The radio-controlled room temperature sensor (transmitter) can be trained to any number of radio-Controlled temperature controllers (receivers). Hence, one sensor can control a number of electric radiators/panels or hot water valves. The transmitting range of the radio-controlled room temperature sensor is very much affected by spatial conditions. Reinforced walls, ceilings and metal housings, for instance, reduce the range.
4. Commissioning
Depending on the type of device or packaging size, the device is either delivered closed or open for faster assembly. In this state, the radio room temperature sensor is not operational. Operational readiness is only established by inserting the batteries and teaching the radio room temperature sensor (transmitter) to the radio temperature controller (receiver) (here on point 5). Learning function. In the case of closed devices, for later orientation before removal of the setting button, the button is set to a scale number. The setting of the adjusting button after insertion or replacement of the batteries is thus simplified. When inserting the batteries, care must be taken to ensure correct polarity. In order to achieve the maximum running time, only new batteries of the specified design and equivalent quality of original batteries may be used. The correct insertion of the batteries is confirmed by a short green lighting up of the lamp. For others, please indicate point 9. Observe illuminated indicators. For the sake of simplicity, learning to the radio temperature controller should be carried out before closing the sensor cover; however, it can also take place later by means of the housing curve under the setting button (cf. Point 13.
The sensor type or packing size determines whether the sensor is delivered in a closed condition or – for rapid mounting – in an open condition. In this condition, the radio-controlled room temperature sensor is not ready for operation. Only when the batteries are inserted and the radio-controlled room temperature sensor (transmitter) is trained to the radio -controlled temperature controller (receiver) is operational readiness on hand. Learn function. Before taking off the setting button, the button of sensors in a closed condition is set to a scale number for subsequent orientation. This makes it easy to fit the setting button after insertion or change of batteries. Make sure poling is correct when inserting the batteries. For maximum running time, only new batteries of the specified type and of the same quality as the original ones are to be inserted. A short green flash of the lamp confirms their correct insertion. Please note Item 9 should give other indications. It is easier to train the radio-controlled temperature controller before closing the sensor cover; however, it can still be done later through the housing hole under the setting button (cf. Item 13
4.1 Range limitation of the temperature setting
The setting range can be limited mechanically under the button with the adjusting lugs (cf. Point 14.
The setting range can be mechanically limited under the button using the setting pins (cf. Item 14.
5. Learn function
With the learning function, a radio room temperature sensor (transmitter) is assigned to the respective radio temperature controller (receiver). Before learning: From the following 3 starting situations, a radio room temperature sensor can be taught to a radio temperature controller: 1. In this case, the lamp on the radio temperature controller is continuously red. 2.) A radio room temperature sensor has already been learned from the radio temperature controller within the last hour. In this case, the lamping light on the radio temperature controller is green and thus indicates the correct radio connection to said sensor. 3.) A radio room temperature sensor has already been learned from the radio temperature controller for more than 1 hour. In this case, the lamp on the radio temperature controller is off and thus indicates the correct radio connection to this sensor. In the case of radio temperature controls with status indication of output, the lamp may be off or yellow continuous luminaires. The following procedure: The learning button of the radio room temperature sensor is accessible with a suitable object when the cover is open or after removal of the setting knob through the bore. 1.) Short press the learning button on the radio temperature controller ➞The lamp on the wireless temperature control flashes red for a maximum of 30 seconds. If no radio room temperature sensor is learned during this time, the lamp stops flashing and changes back to its initial state. 2.) Press and hold the learning button on the radio room temperature sensor until the lamp changes from red flashing to green blinking at the radio temperature controller. During the press of a button on the radio room temperature sensor, its lamp flashes red. 3.) Let go of the learning button on the radio room temperature sensor ➞The lamp on the wireless room temperature detector goes out. After correct learning, the lamp lights up on the radio temperature controller for approx. 1 hour green, the regulation is now active. For other indications on the radio temperature control, please note its operating instructions point light indicators. After the radio room temperature sensor has been placed in the space to be controlled, the correct radio connection must again be checked on the radio temperature controller using the green continuous lamp of the lamp. For this purpose, see the operating and installation instructions of the radio temperature controller "Indication of installation mode".
The Learn Function Assigns a Radio-Controlled Room Temperature Sensor (Trans-Mitter) to the Right Radio-controlled Temperature Controller (Receiver). Before learning: A radio-controlled room temperature sensor can be trained to a radio-Controlled temperature controller from the following 3 situations at the outset: 1.) No radio- Controlled room Temperature Sensor is trained towards the radio- control led temperature controller. In this case, the lamp at the radio-controlled tempe- rature controller is continuously red. A radio-controlled room temperature sensor has been trained to the radio- controlled temperature controller within the last hour. In this case, the lamp at the radio-controlled temperature controller lights up green thus indicating correct radio contact to this sensor. A radio-controlled room temperature sensor has been trained to the radio- controlled temperature controller for over 1 hour. In this case the lamp at the radio-controlled temperature controller is off and thus indicates correct radio contact to this sensor. In the case of radio-controlled temperature controllers with output status indication, the lamp can be both off and also show a conti- nuous yellow light. Learn process: The radio-controlled room temperature sensor learn key can be accessed when the cover is open or after a suitable object has been used to take off the setting button through the hole. Briefly depress the learn key at the radio-controlled temperature controller ➞The lamp at the Radio-Controlled Temperature Controller flashes red for a maximum 30 seconds. If no radio-controlled room temperature controller is trained within this time, the lamp stops flashing and returns to its starting state. Depress learn key at the radio-controlled room temperature sensor and keep pressed until the lamp at the Radio-Controlled Temperature Controller changes from red to green flashing. While pressing the button at the radio-controlled room temperature sensor, its lamp flashes red. Release learn key at the radio-controlled room temperature sensor ➞Its lamp is extinguished. Following correct training, the lamp at the radio-controlled temperature controller lights up green for approx. 1 hour – The control system is now active. If indica- tion is different at the radio-controlled temperature controller, then consult its operating instructions under Item LED Display. After placing the radio-control- led room temperature sensor in the room to be controlled, correct radio contact is to be re-checked at the radio controlled temperature controller. This is shown by then lamp’s continuous green light. Please note here the operating and installation instructions of the radio-controlled temperature controller “Dis- playing the installation mode”.

6. Logging off function (Delete function)
In order to log off the radio room temperature sensor (transmitter) from the radio temperature controller (receiver), the learning button of the radio space temperature sensor must be pressed permanently until the lamp has reached approx. 10 seconds from red blinking to permanent red. If the lamp is permanently red, the learning button of the radio temperature controller must also be pressed briefly. For this purpose, observe the operating and installation instructions of the radio temperature controller.
To log off the radio-controlled room temperature sensor (transmitter) from the radio -controlled temperature controller (receiver), the learn key of the radio – controlled room temperature Sensor must be pressed for as long as it takes the lamp to change from red flashing to continuous red after approx. 10 seconds. When the lamp continues to light up red, the learn button of the radio-controlled temperature controller must also be depressed. Note here the installation instructions of the radio-controlled temperature controller.
7. “Battery empty” indication
The lamp on the radio room temperature sensor flashes red for the first 5 seconds per minute. The battery idle state is displayed for at least 7 days, while maintaining the control. After changing the batteries, there is no need to relearn the radio room temperature sensor.
The radio-controlled room temperature sensor lamp flashes red for the first 5 se conds of every minute. “Battery empty” indication is shown for at least 7 days and with the control system being maintained during this time. The radio-controlled room temperature sensor does not need to be re-trained after changing the battery.
8. Functional fault at the radio-controlled room temperature sensor
The lamp on the radio room temperature sensor (transmitter) flashes alternately red/green. If the setting button has been rotated outside of the scale range, the lamp also flashes red/green. Turn the button back into scale, and the lamp goes out. Emergency running characteristics of the control ➞see operating instructions for radio temperature controller (receiver).
The radio-controlled room temperature sensor (transmitter) lamp alternatively flashes red/green. Turning the setting button beyond the scale range would also result in the lamp flashing red/green. With the button back within the scale range, the lamp is extinguished. Emergency running features of the control system ➞ see Operating Instruction of the radio-controlled temperature controller (receiver).
9. LED displays at the radio-controlled room temperature sensor
Lamp made of: The radio room temperature sensor works correctly. Prerequisite, the batters are inserted and loaded correctly. Lamp flashes red: The batteries are empty and must be changed, the control is active during flashing and works correctly. ➞see point 7. Battery vacancy indicator and point 4. putting into service. Lamp is continuously red: After approx. 10 seconds The lamp is permanently illuminated red, the radio room temperature sensor is in log-off mode. (cf.) Point 6. Lamp flashes alternately red / green: Internal error. The device must be inspected at the factory (cf. Point 8.
Lamp off: The radio-controlled room temperature sensor functions correctly given that the batteries are properly inserted and charged. Lamp flashes red: The batteries are empty and must be changed. The control system is active during flashing and functions correctly. See Item 7. “Battery empty” indica- tion and Item 4 Commissioning Lamp is continuously red: Depressing the learn key for some 10 seconds is followed by a permanently red lamp; the radio-controlled room temperature sensor is in the logging-off mode. (cf.) Item 6 Lamp flashes alternatively red/green: Internal fault. The sensor must be examined at the factory (cf.) Item 8
10. Function and assignment check of the radio contact
This function serves for subsequent monitoring of the correct allocation of radio room temperature sensors (transmitter) to various radio temperature controllers (receiver). Confusions are thus easily recognized even at a later time. ➞Step learning button on the radio room temperature sensor permanently ✞The lamp on the wireless room temperature detector flashes red during this time. If the lamp starts to flash green on the radio temperature controller, the radio room temperature sensor is trained and connected. Attention! Press the learning button on the radio room temperature sensor for no longer than about 10 seconds. If the learning button on the radio room temperature sensor is pressed for more than about 10 seconds, it switches to log-off mode (cf. Point 6.
This function is for subsequently checking the correct assignment of radio-controlled room temperature sensors (transmitters) to either various radio-controlled temperature controllers (receivers). This makes it easy to spot mix-ups at a later date. Constantly depressing learn key at the radio-controlled room temperature sensor ➞the lamp at the Radio-controled room temperature detector flashes red simulta- neously. The radio-controlled temperature controller lamp starting to flash green means that the radio-Controlled room temperature sensor is trained on it and has contact. Caution! Do not depress the learn key at the radio-controlled room tem- perature sensor for more than 10 seconds – otherwise it will change over to the logging-off mode (cf. Item 6.
11. Mounting
The apparatus is advantageously mounted with double-sided adhesive tape or, in the case of walls covered by paper, directly on an inner wall opposite to the heater at a height of 1.50 m. Table, shelf or cabinet locations are not suitable due to unfavorable air flow and influence of external heat sources (e.g. Persons, devices, candles, sunlight etc.) not recommended. An adhesive strip is included in the package.
The device should, for practicality reasons, be mounted on an internal wall opposite the related heater at a height of 1.5 metres above floor using a double adhesive tape or commercially available screws. Tables, shelves or cupboards are not advisable in view of unfavourable air currents and effects from extra- neous heating sources (e.g. People, Equipment, Candles, Solar Radiation. An adhesive strip is enclosed in the scope of delivery.
11. Technical data
Supply voltage: Battery 2x Micro AAA, capacity 1100mAh, Do not use batteries! Battery life: approx. 5 years, Attention! Change the batteries at least every 5 years Temperature sensor: internal setting range: 5 ... 30°C Measuring accuracy: 0.1K Sensor tolerance: ±1K Setting scale: °C Scale Transmission frequency: 868.3MHz Transmitter range: line of sight approximately 150 m, in buildings up to 30 m – point 3. Take note! permissible ambient temperature: -10 ... +50°C, permissable storage temperature: –10 ...+50°C and permissive humidity: max. 95%rH, non-dewing housing: Berlin 1000 Housing material and paint: ABS plastic, pure white (similar to RAL9010) Protection class: III protection type: IP20 mounting type: Wall installation by means of screws or adhesive strip
Supply voltage: 2 micro AAA batteries, capacity 1100mAh, Do not use rechargeable batteries! Durability of the battery: Approx. 5 years, Caution! Change the batteries at least every 5 years Temperature sensor: internal type Setting range: 5 ... 30°C Measuring accuracy: 0.1K Sensor tolerance: approx. ±1K Adjustment scale: scale in °C Transmit frequency: 868.3MHz transmitter range: Line of sight approx.150m, in buildings approx. Up to 30m. Note Item 3! Admissible ambient temperature: -10 ... +50° C. Admissable storage temperature: –10 ...+50° C Admissibility air moisture: max. 95 %r.h., non condensing Housing model: Berlin 1000 Housed material and colour: ABS plastic, pure white (similar to RAL9010) Protection class: III Degree of protection: IP20 Way of mounting: on the wall by means of screws or adhesive strips
This apparatus, when used as intended, meets the essential requirements
This product complies, when used as intended
with the basic requirements and all
and the other relevant provisions
Relevant provisions of the
Directive 1999/5/EC.
EC Directive 1999/5/EC.


Learn key with housing in closed condition
Unscrew the screw below the setting button
Learn key with the housing in opened condition
For opening, raise the housing cover here and rotate the cover in an anti-clockwise direction. For opening, lift the housing cover here and turn it counter-clockwise.
Maximum temperature value setting lug Pin for the setting of the maximum temperature value

Accessibility Should a disturbance occur to one of our products, we will naturally be at your side with advice and deeds. AEG Haustechnik | Customer service | Fürstenberger Straße 77 | 37603 Holzminden Tel. 05531 702-111 | Fax 05530 702-95890 | [email protected] Further addresses are listed on the last page. Our customer service can be reached by phone around the clock, also on Saturdays and Sundays as well as public holidays. Customer service assignments are made during our business hours (from 7.30 to 16.30, Fridays until 14.00). As a special service we offer customer support assignments until 10 pm. For this special service as well as customer support operations on Sams, Sunday and public holidays higher prices are charged. Guarantee terms These guarantee conditions regulate additional warranty services from us to the end customer. They are in addition to the legal warranty claims of the customer. The legal warranty claims against the other contractual partners are not affected. These warranty terms apply only to devices purchased as new by the end customer in Germany. A guarantee contract shall not be concluded if the end customer purchases a used device or a new device from another end user. Content and scope of the guarantee The warranty is provided if a manufacturing and/or material defect occurs on our devices within the guarantee period. However, the warranty does not include services for such equipment in which faults, damage or defects due to calcification, chemical or electrochemical action, erroneous installation and/or installation, improper alignment or operation of the system and/or incorrect use; use occur. Likewise excluded are services due to defective or omitted maintenance, weather influences or other natural phenomena. The warranty expires if repairs, intervention or modifications have been made to the device by persons not authorised by us. The guarantee covers the careful examination of the device, first determining whether a warranty claim exists. In the event of a guarantee, we alone decide on how to correct the error. We are free to have a repair of the device carried out or carry it out ourselves. Any replaced parts become our property. For the duration and range of the warranty, we cover all material and assembly costs. Insofar as the customer has received services due to the case of a guarantee on account of legal warranty claims against other contractual partners, we shall not be obliged to provide any service. If a guarantee is provided, we do not assume liability for the damage of an equipment by theft, fire, riot or. . Causes. In addition to the above-proposed guarantee services, the end customer cannot assert any claims under this warranty for indirect damage or consequential damage caused by the device, especially compensation of damage incurred outside the device. Legal claims of the customer towards us or against third parties remain unaffected.
Guarantee period For appliances used in private households, the guarantee period is 24 months; otherwise (e.g. B. if the equipment is used in commercial, craft or industrial enterprises, the warranty period shall be 12 months. The warranty period for each device begins with the delivery of the device to the customer who uses it for the first time. Guarantees shall not lead to an extension of the duration of the guarantee. The guarantee provided will not set in motion a new warranty period. This applies to all warranty services provided, in particular for any installed spare parts or replacement delivery of a new device. Use of the guarantee Warranty claims must be registered with us before the expiry of the warranty period, within two weeks after the defect has been detected. The error, the device and at time of detection shall be reported. As proof of guarantee, the invoice or another dated proof of purchase must be attached. If the aforementioned information or sub-objections are missing, there is no guarantee claim. Guarantees for equipment purchased in Germany but used outside of Germany We are not obliged to provide guarantee services outside the Federal Republic of Germany. In the event of malfunctions in a device used abroad, this must be sent to customer service in Germany at the risk and expense of the customer. The return is also at the risk and expense of the customer. Any legal claims of the customer towards us or against third parties remain unaffected in this case. Devices purchased outside Germany For devices purchased outside Germany, this guarantee does not apply. The respective legal regulations and, if applicable, the delivery conditions of the national company or the importer.

Sales centre
Australia STIEBEL ELTRON Australia Pty. Ltd 6 Prohasky Street Port Melbourne VIC 3207 Tel. 03 9645-1833 Fax 03 9644-4366
EHT Haustechnik GmbH Brand distribution AEG Gutenstetter Straße 10 90449 Nuremberg [email protected] www.aeg-haustechnik.de Tel. 0911 9656-250 Fax 0911 9656-444
Austria STIEBEL ELTRON Ges.m.b.H Eferdinger Str. 73 4600 Wels Tel. 07242 47367-0 Fax 07242, 47367-42
Woodminden Fürstenberger Str. 77 37603 Wood mints Letter address 37601 Timber mint
Belgium STIEBEL ELTRON bvba/sprl 't Hofveld 6 - D1 1702 Groot-Bijgaarden Tel. 02 42322-22 Fax 02 42322-12
The customer service and spare parts sale is available in the period from Monday to Thursday, between 7.15 a.m. and 6.00 p.m and Fridays between 7.10 a. m. and 5.00 pm. Reachable by fax number:
Czech Republic STIEBEL ELTRON spol. s r.o. K Hájům 946 155 00 Praha 5 - Stodůlky Tel. 251116-111 Fax 235512-122
Hungary STIEBEL ELTRON KFT. Gyár u. 2 2040 Budaörs tel. 01 250-6055 Fax 01 368-8097
Netherlands STIEBEL ELTRON Nederland BV Daviottenweg 36 5222 BH 's-Hertogenbosch Tel. 073 623-0000 Fax 073 723-1141
Poland STIEBEL ELTRON Polska Sp. c O.O. ul. Działkowa 2 02-234 Warszawa Tel. 022 60920-30 Fax 02260920 - 29
Russia STIEBEL ELTRON LLC RUSSIA Urzhumskaya street 4, building 2 129343 Moscow Tel. 0495 7753889 Fax 0495 675 3887
Switzerland STIEBEL ELTRON AG Industrie West Gass 8 5242 Lupfig Tel. 056 4640-500 Fax 0564640-501
www.aeg-haustechnik.de
© EHT Haustechnik
A 318977-38650-1513
B 318972-38650-9038
4<AMHCMO=bijha>
AEG is a registered trademark used under license from AB Electrolux (publ).
Mistake and technical changes reserved! Subject to errors and technical changes! | Sous réserve d’erreurs et de modification techniques! | Onder voorbehoud van vergessingen and technical wijzigingen! Salvo error o modificación técnica! | Rätt till misstag och tekniska ändringar förbehålls! | Excepto erro ou alteração técnica | Zastrzeżone zmiany techniczne i ewentualne błędy | Omyly a technické změny jsou vyhrazeny! A muszaki változtatások és tévedések jogát fenntartjuk! | Отсутствие ошибок не гарантируется. Возможны технические изменения.’ Chyby a technické zmeny sú vyhradené! 1505
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.