USERS OF THIS MANUAL
Standards in force
This manual is intended for: - the engineer responsible for regulations - the installer - the user - the maintenance technician
The products in this manual are provided with a European certificate (European Directive 92/42/EEC . They also have the Belgian .OPTIMAZ-label (Stook oil burner).
The following symbols are used in this manual:
This manual is an integral part of the equipment to which it refers and must be handed over to the user.
The installation and maintenance of the product shall be entrusted to approved technicians in accordance with applicable requirements.
The manufacturer may never be held liable for any damage resulting from errors in the installation or use of equipment or accessories that have not been approved by the manufacturer.
- Electrocution hazard.
Failure to comply with instructions regarding the
The operation and adjustment of this product may result in serious personal injury or environmental contamination.
This device is not equipped for use by
persons (included children) with limited physical or mental potential. Or persons who have not acquired the necessary knowledge except if they are accompanied by a person who is his own with the installation and responsible for their safety, health and well-being.

Use of the boiler
Operation of the circulating pump: The circulation pump is controlled by the minimal thermostat, mounted at the back of the boiler. It is set to 45 °C by default, so that the circulating pump is switched on later during start of the burner in order to avoid any risk of rust formation in the combustion chamber.
To ensure the proper functioning of your installation
must be maintained by a qualified technician before the heating season each year. Start of the burner: In normal conditions, the burner automatically starts when the temperature of the boiler drops below its set value.
Manometer pressure heating system Your installation must be equipped with a safety valve, adjusted to 3 bar.
Make sure that the installation is always under water pressure. Cold and after ventilation of the installation, the pressure gauge shall always be between 0.5 and 1.5 bar depending on the height of the building.
Before each intervention to the boiler,
The boiler's power supply shall be interrupted by the external cabinet switch. The main switch of the control board shall also be placed in the .offfffff/s position.
Layout of the control board (fig. 1)
User does not have access to the internal
Safety valves (fig. 8, page 8 - No 3 If water is running out of one of the safety valves, you must stop the boiler and contact your installer
components of the control board.
A monthly check is recommended: The lever of the draining device lights up for a few seconds to verify the proper operation of the safety valve.
If you find an irregularity during this short test,
Please contact your installer
The water that runs out of the safety valve can be very hot
and cause severe burns.
If the burner does not work:



Fig. 2 Fig. 3

General description
Covering The boiler is coated with a steel coat which was first degreased and phosphatized and subsequently at 220°C covered with a special lacquer. Presentation of the boiler (fig. 4) and (Fig. 5)
Simple and safe control One button is sufficient to regulate the temperature of the heating water. This arrangement is done with the control thermostat, whose sensor is placed in the outgoing stream of the boiler.

Preparation of hot drinking water The boiler .N• The product can be combined with the smart boiler (100 L) or any other ACV boiler.
External boiler body The external boiler body contains the primary liquid and is made of thick STW 22 steel.
Smoke channel The boiler's smoke canal is accessible from the front and is built up with 6 removable chromed stainless steel curves. This system is specially developed to improve the efficiency of the boiler.

Burning chamber The boiler is equipped with a large water-cooled combustion chamber that has been specially developed to ensure good flame development of the burner.
Removable fireplace door The hinged (left or right) fireplace doors are made of STW 22 steel. The door is protected from the flame by a ceramic fibre mat and vermiculite brick.
Insulation The boiler body is insulated by a 30 mm glass fibre mat.

General
Conditions of operation
The appliances are fully mounted, tested and packed in shrink film on a wooden palette with bump edges. When receiving and after removing the packaging, please check that the devices have not been damaged during transport. The dimensions and weights below shall be taken into account for transport.
Maximum operating pressure (boil filled with water) - Heating circuit 3 bar - Drinking water Circle 10 bar (*)
Test pressure (boil filled with water) - Heating circuit 4,5 bar - Drinking water circle 13 bar (*)
(*) If the boiler is connected to a hot water heater.



A mm W mm C mm D Ø mm E mm F mm G mm Kg (*)
N 1 470 700 566 130 550 445 260 108
N 2 470 765 566 130 615 510 260 122
N 3 530 805 656 150 645 550 260 157
(*) The weights given are empty.
Peak flow rate at 45°C (ΔT = 35°C) L/10’ 202 202
Peak flow rate at 60 °C (ΔT = 50°C) L/10’ 117 117
Load (input) kW 22,0 / 28,0 30,4 / 40,0 40,0 / 57,0
Net rated power (output) kW 20,0 / 25,0 27,0 / 35,7 36,5 / 51,0
Reduced working load of flue gases mbar 0,15 0,17 0,15
The temperature circuit content L 31 37 53
Connection heating Ø 1” 1” 1” 1/4
Operating regime at 85°C

A. Upper ventilation B. Sub-exercise C. Tractor D. E. Lookhole. Height of the F. Screen diameter

Accessibility The boiler room should be large enough to ensure easy access to the boiler. It is advisable to provide the following minimum distances (mm) around the boiler:
- front 500 - rear 150 - sides 100 - top 300
Ventilation The boiler room shall be equipped with an underlighting and a upper ventilation (fig. 7).
Every user must ensure that the ventilation of the boiler room complies with local requirements.
For information: the table below shows the values according to Belgian regulations.
Ventilation N 1 N 2 N 3
Supply fresh air m3/h 50 72 102
Upper ventilation (A) dm2 150 150 150
Sub-exercise (B) dm2 150 150 170
the above table is only a guide.
Base The base (or ground) on which the boiler is placed, must be made of non-combustible material.
The high efficiency of our boilers means that the
The exhaust gases are discharged at a very low temperature. Smoke gas condensation is therefore possible, which in some fireplaces could cause damage To avoid that risk we strongly recommend you to provide the chimney with a tube. For further information please contact your installer.
The diameter of the fireplace shall not be less than the
diameter of the boiler's discharge pan.
Shower connection type: B23 (fig. 7) The connection to the fireplace is done with a metal tube, which is placed diagonally between the boiler and the chimney.
A fireplace is necessary.
Scrap N 1 N 2 N 3
E = 5 m Ø min. F mm 130 143 170
E = 10 m Ø min. F mm 130 130 143
E = 15 m Ø min. F mm 130 130


Connection example single circuit (fig. 8) 1. Fulfill valve installation 2. Retro-return valve 3. Safety valve with pressure gauge (set at 3 bar) 4. Expansievat 5. Circulation pump 6. Closing valve heating 7. Environmental thermostat (option) 8. Tap tap 9. Automatic air vent
Nutrition principle The boiler works with single phase current 230 V - 50 Hz. A cabinet with main switch and 6A fuses shall be mounted on the outside of the boiler to allow interruptions in the kettle's power supply during maintenance operations and before each intervention on the appliance.
Conformity The installation must comply with the applicable local standards and regulations.

The drain valve and the safety valve shall be connected to the sewage system.

Electrical wiring of boilers N1/N2/N3 (fig. 11) 1. Main switch 2. Minimum thermostat 45°C (T.O.D.) 3. Summer winter switch 4. Safety thermostat with manual re-initiation (max. 103°C) 5. Burner 6. Lockdown Signpost 7. Environmental thermostat (option) 8. Circulation pump (not included) 9. Control thermostat of the boiler

B. Blue Bk. Black Br. Brown G. Grey V. Violet R. Red W. White Y/Gr. Yellow / Green
Boiler Control BC 01
Boiler Control BC 03



Installation with 2 circulation pumps(fig. 12)

Installation with a circulation pump and three-way crane with motor (fig. 13)



1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Electric connection of BC 01 with 1 threeway crane with motor + 1 pump

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

230 V ~ 50 HZ PE PE 1 6 2 3 4
1 2 3 4 5 6 7 8 9 10 11
this institution, an · bridging between

Maintenance
Fill the heating circuit (fig. 14)
RECOMMENDATION
You must have the boiler maintained once a year. That maintenance and the burner control must be entrusted to a qualified technician.
The drinking water circuit must be absolutely filled, especially before the heating ring is filled.
1. The main switch of the control board shall be placed in the .offfffff/position. 2. Shut down the electric power supply of the boiler with the switch from the external cabinet and close the fuel feed valve 3. Remove the front piece from the boiler (1). 4. The fireplace door (2) by unscrewing the two mounting nuts. 5. The stainless steel curves (3) and the Council. 6. Brush the smoke channels, clean the fireplace and suck out the soot deposits. 7. Check the condition of insulation of the fireplace door (4). 8. Prior to reassembly the burner's combustion head (5) cleaning. 9. Check the proper functioning of thermostats and safety valves.


- The proper functioning of all thermostats and safety devices
Control: boiler thermostat and safety thermostat with manual re-initiation 103°C. - Check the safety valves of the heating circuit.
The water flowing out of the drain is very hot
and can cause severe burns so keep everyone away from the hot water flow.
Elimination of the heating circuit (fig. 14) 1. Put the main switch of the control board in position .OFFS, interrupt the electric power supply of the boiler with the shell of the external cabinet 2. Clamps (6) turn off the heating circuit. 3. A flexible tube at the tap (8) fasten. 4. The tap valve (8) open the heating circuit to reduce.