Zenith HydroTap
Filtered boiling and chilled drinking water for kitchens and tea rooms.


37671 Zenith HydroTap BC60/85
30281 Zenith HydroTap BC150/175 30271 Zenith HydroTap BC100/125
37201 Zenith HydroTap B10OF 38201 Zenith HydroTap B150F
37691 Zenith HydroTap B60
37291 Zenith HydroTap B100 38291 Zenith HydroTap B150 Disabled Models
Domestic models
30009 Zenith HydroTap HT60 30609 Zenith HydroTap HTD60 36051 Zenith HydroTap HT60/85 36651 Zenith HydroTap HTD60/85
37276 Zenith HydroTap BCD100/125 38286 Zenith HydroTap BCD150/175 37206 Zenith HydroTap BD10OF 38206 Zenith HydroTap BD150F
37601 Zenith HydroTap BF60 (Ambient)
37696 Zenith HydroTap BD60
37296 Zenith HydroTap BD100 38296 Zenith HydroTap BD150
81467 - February 2005
®



Do not allow young children, handicapped or infirm persons, to use the Zenith HydroTap without supervision.
The Zenith HydroTap Chilling unit contains 134A refrigerant under pressure. No part of the unit should be exposed to a naked flame. Maintenance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration mechanic.

If any power cord or plug is damaged it must be repaired only by a qualified technician. To avoid hazards, all installation procedures must be carried out by a suitably qualified tradesperson. The power cord and general power outlet must be in a safe visible position for connection.
Sometimes steam and / or boiling water may discharge through a vent outlet at the mouth of the tap. If the tap is not installed using the Font pedestal, ensure the tap body is located so the tap outlet safely drains into the sink bowl area.
The power point must be located within reach of it’s cable. The appliance must be positioned so that the plug is accessable.

Take care when lifting the Zenith HydroTap undersink unit. Some units may exceed safe lifting limits. Do not lift without assistance. The weights of the units are given in the table under the heading “Installation Requirements”. Do not lift the unit by the doors.
The ambient temperatures this unit should operate within are 5ºC - 35ºC. Proper air circulation must be provided. The system will operate satisfactorily only if the recommended air gaps are provided, these are 65mm min rear clearance and 50mm side clearance. An air vent is provided with each unit for high usage applications, this must be installed in the top half of the cupboard door as a matter of course. An optional fan kit is available and should be used to ensure adequate ventilation. Make sure that the ventilation grilles of the undersink unit are not obstructed.
Zip Hydrotap undersink assembly. The appliance must be placed in a horizontal position, as shown above.
Altitude (not HT boiling only series)
The Zenith HydroTap is equipped with a self-calibrating program which caters for altitude adjustment.
The Zenith HydroTap filter control is preset to 6000 Litres to provide trouble-free flow and operation in most installations. Local water quality conditions may require an alteration to this capacity. In areas where the water has a high concentration of sediment, the preset litre capacity may be shortened to avoid poor flow, taste or odour situations. In areas where the water quality is above average, lengthening the preset capacity may be desirable, but not essential. If any of these changes is needed, follow the instructions on page 11 or contact your Zenith Service Provider.

If this appliance is located where the ambient air temperature could fall below 5ºC when the heater is not in use, do not turn off the appliance electrically. This safeguard does not offer the same protection to the connecting pipework and fittings.
This unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature. This unit must not be positioned in an area that may be cleaned by a water jet. This unit must not be cleaned by a water jet.
These Installation Instructions cover the entire Zenith HydroTap range. Use the chart on the left to identify the model you are using:
Commercial and Domestic Models: BC = Boiling and Chilled, Filtered, Timer BF = Boiling, Filtered BD = Boiling and Ambient Filtered B = Boiling only (unfiltered) D = Disabled Lever controls, (Optional order only) HT = Domestic Models (boiling only are unfiltered, boiling/chilled are filtered) Boiling Water Capacity: 100 = 100 cups in one hour 150 = 150 cups in one hour Chilled Water Capacity: (BC only) 125 = 125 glasses in one hour 175 = 175 glasses in one hour Filtration: (BC, BD and BF only) Note: The Cup measurement = 167mls, the Glass measurement = 200mls.
Cups of Boiling Water
Glasses of Chilled Water
Before installing ensure that the following have been provided at the installation site:

In addition to normal tools, the following will be required:
When installing a Font unit:
Step A - Installing the tap (all models)
supplied to go in between the Spider Clamp and the underside
of the sink top. Position it here.

the HydroTap unit. Failure to do this may result in poor water delivery.
installation is complete.





Step D - Connecting the water supply (all models)
To prevent sediment from entering the Zenith HydroTap at connection, flush water through the supply line thoroughly before connection to the Zenith HydroTap. Open the access door and check that the filter is in place and secure. Connect the water supply to the undersink unit using the attached flexible hose. Turn on water and check for leaks. If no leaks are evident turn the poer on.
Step E - Testing and commissioning (all models except boiling only HT models)
Filter Flush Mode (filtered models only)
Use these buttons to scroll through the menu
The display screen will show which model you have. Have a bucket or similar container (not supplied) at the ready to hold a quantity of water that is ejected while the Filter Flush Mode is in operation. Open the filter access door on the front of the HydroTap and the filter cartridge will be exposed. Located to the rear RHS of the cartridge is a fixed flush line, approx 600mm long and the flush line stop cock. Place the free end of the flush line into the bucket or container (not supplied).

Use these buttons to activate and de-activate
Turn “ON” both water and electricity supplies and open the flush line stop cock. The display will show Filter Flush Mode. To activate press adjust ∧. Run at least 7.5 Ltrs of water through to activate the filter membrane. Press the adjust ∧button again to stop the Filter Flush Mode. Turn OFF the Filter Flush stop cock and re-locate the tube and stop cock in the filter compartment. Turning OFF the Filter Flush Mode puts the HydroTap into calibration mode. Press adjust ∧to start calibration.The element will now cycle On and heat the water to 95ºC maintaining it at that temperature for a short stabilization period.
Once stabilized, the element will cycle On, bring the water to boiling point and hold it there for a short period.
The unit now carries out a self calibration function to ensure correct temperatures are maintained. During this period the Red LED on the Tap Head assembly flashes slowly until the calibration function is complete.
Once this step is complete (approx 5 minutes) the unit will default to normal operation.
When starting, both Boiling and Chilled cycles activate similtaneously after calibration has taken place, the descriptions below indicate what happens during each cycle.
Boiling Water Lever Chilled Water Lever

Boiling The unit is now running in normal operating mode. The Red LED will flash until usable temperature is reached.
Before using the HydroTap wait 5 minutes after this point to allow adequate fill time. The unit is now ready for use. Test water delivery from the tap and check for appropriate temperatures. Use cable clips to tidy and secure wiring.
Chilled When water and power is turned On, the Blue LED flashes slowly on the Tap Head assembly. The compressor activates and water begins to fill the chiller tank at the prescribed rate. When the water is chilled to 10ºC the Blue LED on the Tap Head assembly stops flashing and stays illuminated. The compressor continues to chill down to 5º after which it will cycle Off.
Red Light White Light Blue Light Boiling Filter Status Chilled
Ensure that the clock matches your local time. If not refer to page 15 “Set time”. If Energy Saver Settings are required, the instructions for installing these are described on on page 11 “Setting the Energy Saver Timer”.
the program selected


5. Feed the hoses and USB cable through the Font base, then through the plastic spacer that sits under the font base but on the bench top, this stops warping of the base plate. Ensure the Tap spout is directly centered over the Font drain. Refit the “Spider Clamp”, nut and washer onto the “All Thread”. Have all the supply tubes and USB cable located evenly between the Spider Clamp legs. When satisfied with the positioning, tighten the fixing nut with the Tube Spanner provided in the kit.

Tap assy hole 38mm
Hole required for Font

8. Ensure the positioning of the snap-on spigot is on the “sink” side of the trap and not the “waste” side. Once positioned, a hole (13mm ID) will need to be drilled to provide waste access to the drain line. The snap-on unit will require suitable sealant to keep it water tight against the waste pipe. Finish by fitting the worm drive clamps tightly on either side of the spigot and fitting worm drive clamps to either end of the drain hose. The drain hose from the Font must have constant fall
Page 8 0f 20 Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005



Do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft cloth or brush and mild soap and water.
Do not spray water over the tap as it may damage the low-voltage electronics.
Undersink units must never be cleaned with water jets.
The Zenith HydroTap notifies the user when filter replacement is due. The default seting is 6000L. When a filter change is due, the Change Filter light flashes once a minute and remains so until reset. The filter status light is located between the Red and Blue Lights on the tap head assembly. Depending on local water quality conditions and usage, the filter change period can be set in increments of 1000L from 1,000L to 10,000L. The filter may also need to be replaced if unpleasant odours or tastes occur.
Some water may drip from the filter head during replacement. Keep a bucket and towel handy to catch drips and mop up any spills. To change the filter:


Set Time To change time, press either Mode ∧or Mode ∨button until Set Time is on the display screen. Press ∧Adjust button to increase time or ∨Adjust button to decrease time. Time increases or decreases in increments of one minute. Hold the Adjust buttons down for rapid increases or decreases.
Set Day Press either Mode ∧or Mode ∨button until Set Day is displayed.
Press ∧Adjust or ∨Adjust to select day.
Filter Life ( factory set at 6000 litres ) Press either Mode ∧or Mode ∨button until Filter Life is displayed.
Press ∧Adjust button to increase Filter Life or ∨Adjust button to decrease Filter Life.
Filter Life increases in 1000 Ltr increments to a maximum of 10000 Ltrs.
Reset Litres Filtered This function is to reset the Filter Change display after a filter has reached the end of its life (refer to “Replace Filter Instructions” section of this document).
Press either Mode ∧or Mode ∨button until Litres Filtered is displayed. Press ∧Adjust once and “Reset Counter” will be displayed, press ∧Adjust button once and “Are You Sure” will be displayed.
Press ∧Adjust once and Litres Filtered will be reset to 0.
Activating Sleep Mode This mode allows the HydroTap to go into Energy Saving mode. In this mode the unit will go to “sleep” after a pre-determined period of inactivity. Press either Mode ∧or Mode ∨button until Sleep Mode is displayed. Press ∧Adjust once to select 2 Hours or twice to select 4 Hours. When the period of inactivity passes, the display will show “Sleep Mode”. During sleep mode the Red LED on top of the tap lever will flash slowly.
Activating On / Off Mode Press either Mode ∧or Mode ∨button until "Monday On" is displayed. To set the time for the unit to turn on press ∧Adjust button until required time is reached.
To set the time for the unit to turn Off press Mode ∧button once and Monday Off will be displayed. Now press ∧Adjust until required time is reached.
If each individual day is to have an “On / Off” time, these steps need to be repeated for each day and for each "On / Off" time.


The HydroTap is equipped with an auxiliary connection point for an exhaust fan on the rear panel close to the cold water inlet / flex and plug area. The fan kit is available as a spare part. The fan operates in parallel with the Condensor fan helping to remove heat from the cupboard space. This fan should be purchased and fitted to the HydroTap if the airfow characteristics of the cupboard space are inadequate for the effective removal of hot air thereby adversly affecting the operation of the HydroTap.
The fan can be installed so that it extracts air from, or forces air into the cupboard space, whichever is the most effective for your installation.
Application of the fan is of paramount importance in situations where the cupboard space reaches temperatures greater than 35ºC.
The HydroTap if equipped with a safety mode that allows protection against accidental operation by Infirmed or disabled persons.
activation.

Symptom Possible Cause Solution
No LED display, no tap head lights or, no water when tap levers are operated.
No power.
Check power supply.
Plug is not located in power socket.
Ensure power plug is correctly fitted and switch is turned ON.
Tap loom is not connected to HydroTap unit.
Check loom connection.
Possible internal fault.
Contact local Zenith service provider.
Program in OFF cycle
Check LCD for information.
No water flow.
Water supply isolated.
Check water supply is on.
Water supply not connected.
Check to ensure plumbing connecting is made.
Power supply not connected.
Check power plug is correctly fitted and switch is turned on.
Tap loom is not connected to HydroTap unit.
Check for loom connection
Possible internal fault.
Contact local Zenith service provider.
Program in OFF cycle.
Check LCD for information.
Slow water recovery after use.
Filter may require replacement.
Check filter usage on LCD screen, if “filter change” is displayed follow instructions on page 13.
Water not hot.
Unit in Sleep Mode.
Touch Hot lever and wait for Red LED to stop flashing.
Unit has just come out of OFF cycle.
Wait for Red LED to stop flashing.
Possible internal fault.
Contact local Zenith service provider.
Water not chilled.
Excessive use, unit refilling or chilling down to temperature.
Wait for Blue LED to stop flashing.
Possible internal fault.
Contact local Zenith service provider.


Item Kit No. Description Item Kit No. Description
1 Z90613 plumbing fittings kit 14 Z90056 braided hose
2 Z90614 safety solenoid kit 15 Z90635 level sensor kit cold tank BC100/125
3 Z90615 double solenoid kit 15 Z90627 level sensor it BC150/175
4 Z90631 gasket and elbows kit cold tank 16 Z90636 relay compressor kit BC100/125
5 Z90626 dryer-filter kit nut and tube 16 Z90024 relay compressor kit BC150/175
6 Z90632 evaporator kit BC100/125 17 Z90637 compressor kit BC100/125
6 Z90641 evaporator kit BC150/175 17 Z90023 compressor kit BC150/175
7 Z90633 sensor probe kit 18 Z90639 fan motor kit BC100/125
8 Z90634 pump kit cold 18 Z90640 fan motor kit BC150/175
9 Z90622 PCB kit BC100/125 & BC150/175 19 Z90437 capacitor kit BC100/125
9 Z90663 PCB kit domestic BC60/85 19 Z90020 capacitor kit BC150/175
9 Z90664 PCB kit B100 & B150 20 Z90185 loom level sensor kit
9 Z90665 PCB kit domestic B60 21 Z90652 transformer kit-auxillary fan
9 Z90666 PCB kit boiling B100F & B150F 22 Z90657 second solenoid boiling only model
9 Z90667 PCB kit domestic B60F 23 Z90041 38mm chassis punch
9 Z90668 Pcb kit domestic ambient BF60 24 Z90671 3ag-10amp fuse
10 Z90623 transformer kit 25 Z90670 2ag-2amp fuse
11 Z90624 leak sensor kit 26 Z90669 2ag-1amp fuse
12 Z90625 control panel kit
13 Z90628 stop valve and john guess fitting kit filter


Item Kit No. Description Item Kit No. Description
1 Z90613 plumbing and fittings kit 13 Z90130 clips kit
2 Z90614 safety solenoid kit 14 Z90628 stop valve and john guess fittings kit for filter
3 Z90615 double solenoid kit 15 Z90056 braided hose inlet
4 Z90616 gasket and elbow kit BC 100/125 16 Z90629 level sensor kit hot tank BC100/125
4 Z90617 gasket and elbow kit BC 150/175 16 Z90630 level sensor kit hot tank BC150/175
5 Z90579 overload kit 17 Z90186 loom-overlad kit
6 Z90618 element 1500W kit 18 Z90187 loom-compressor to fan kit
6 Z90619 element 1800W kit 19 Z90188 loom-solenoid kit
7 Z90620 sensor probe kit 20 Z90189 loom-level sensor kit hot
8 Z90621 pump kit hot 21 Z90190 loom+gland main PCB to tap
9 Z90622 PCB kit BC 100/125 & BC 150/175 22 Z90652 transformer kit auxillary fan
10 Z90623 transformrer kit 23 Z90657 secondary solenoid boiling only models
11 Z90624 leak sensor kit 24 Z90617 elbow and gasket kit BC 150/175
12 Z90625 control panel kit


1 Z90656 Plumbing and Fittings kit
2 Z90614 Safety Solenoid Kit
3 Z90657 Single Solenoid Kit
4 Z90658 Gasket and Elbow Kit BC 100/125
5 Z90579 Overload Kit
6 Z90618 Element 1500 watt Kit
7 Z90620 Sensor Probe Hot
8 Z90621 Pump Kit Hot
9 Z90689 PCB Kit Boiling Only
10 Z90624 Leak Sensor Kit
11 Z90130 Clips Kit
12 Z90056 Flexible Inlet Hose Kit
13 Z90690 Level Sensor Kit Hot Tank H/T 60/85
14 Z90186 Loom-Overload Kit
15 Z90661 Loom-Solenoids Kit
16 Z90189 Loom-Level Sensor Kit Hot
17 Z90190 Loom and Gland Main PCB to Tap




The Zenith appliance you have chosen is precision-built from the finest materials available and should give many years of trouble free service.
Certain warranties may be implied by law into your contract with Zenith. The warranty provided below is additional to these implied warranties and nothing set out below shall limit your statutory rights or rights at law.
Parex Appliances warrants that, should any part fail within 12 calendar months of installation, that part will be repaired or replaced free of charge by Parex Appliances or its Distributor or Service Provider, except as set out below, provided the appliance is installed and used strictly in accordance with the instructions supplied, and that failure is not due to accident, misuse, abuse, unsuitable water conditions, or to any alteration, modification or repair by any party not expressly nominated by Parex Appliances.
No costs are payable by the customer other than any mileage or travelling-time charges incurred by a Zenith Service Provider or the cost of removal, cartage and re-installation of any component of the appliance if it needs to be returned for repair its Distributor.
This warranty does not cover damage resulting from non-operation of the appliance or consequential damage to any other goods, furnishings or property.
No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary according to water quality and the rate of water consumption.
Parex Appliances does not exclude, restrict or modify any liability that cannot be excluded, restricted or modified or which cannot, except to a limited extent, be excluded, restricted or modified as between the owner or user and Parex Appliances under the laws applicable.
Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Parex Appliances is entitled to do so, the liability of Parex Appliances under any statutory warranty will be limited at Parex Appliances option to the replacement of the appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the appliance.
Parex Appliances 103 Central Park Dr Henderson Auckland
Zenith Hydrotap - Installation & Operating Instructions - 81438 - June 2004 Page 20 of 20
Head Office
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.