Instruction/ maintenance manual of the product K5EU090A50A York
Go to page of 12
GENERAL These completely assembled blower units are manufac- tured under ISO 9002 Quality System Certification and include a well-insulated cabinet, a DX cooling coil with copper tubes and aluminum fi.
2 Unitary Products Group 550.39-N4YI T ABLE OF CONTENTS General ................................................................................ 1 Reference ............................................................................ 1 Inspection ....
carrier's agent should be made in writing. See Local Dis - tributor for additional information. LIMIT ATIONS These units must be installed in accordance with applicable na - tional, local and municipal safety codes.
CLEARANCES The clearances listed on the unit dimension drawing (Figure 9) are required for the proper service and opera - tion of the unit. RIGGING AND HANDLING Be careful when moving the unit. Do not remove any packaging until the unit is near its final location.
REFRIGERANT MAINS Many service problems can be avoided by taking adequate pre- cautions to provide an internally clean and dry system, and by us- ing procedures and materials that conform with established standards. Hard drawn copper tubing should be used where no apprecia - ble amount of bending around pipes or other obstructions in necessary .
Before brazing the refrigerant lines to these connections, remove the short panel from the unit frame and slide it (along with the grommets) onto the refrigerant lines. Af - ter the brazed joints have cooled, slide the panel back into place and secure it to the unit frame.
3. Using an inclined manometer , determine the pressure drop across a dry evaporator coil. Since the moisture on an evaporator coil may vary greatly , measuring the pressure drop across a wet coil under field conditions would be inac - curate. T o assure a dry coil, the refrigerant system should be de-energized while the test is being run.
8 Unitary Products Group 550.39-N4YI KEU090 - SUPPL Y AIR BLOWER PERFORMANCE 1 - (CFM) BLOWER SPEED RPM AIRFLOW ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (KW) ESP2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW) ESP 2 (IWG) OUTPUT (BHP) INPUT (kW 2400 CFM 2700 CFM 3000 CFM 3300 CFM 3600CFM 600 0.
Unitary Products Group 9 550.39-N4YI T ABLE 5 - ACCESSOR Y ST A TIC RESIST ANCE (IWG) ACCESSORY EXTERNAL ST A TIC PRESSURE DROP RESIST ANCE IWG/pA BLOWER CFM/m 3 /s 2400 / 1.1 2700 / 1.3 3000 / 1.4 3300 / 1.6 3600 / 1.7 Electric Heat 10k W 0.01 / 2.5 0.
10 Unitary Products Group 550.39-N4YI FIG 9 - UNIT DIMENSIONS AND CLEARANCES Overall dimension of the unit will vary if an electric heater , a supply air plenum or a base is used. This dimension is required for removal of the DX coil. Only 26" is required for normal servicing.
Unitary Products Group 11 550.39-N4YI MOTOR SPECIFICA - TIONS •1450 RPM •380/415-3-50 •Solid base •56 Frame •Inherently protected Permanently lubricated ball bearings POWER AND CONTROL WIRING Install electrical wiring in accordance with applicable national, local and municipal codes.
Unitary Products Group P .O. Box 1592, Y ork, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in U.S.A Copyright © by Y ork International Corporation 1994. All Rights Reserved. 550.39-N4YI MAINTENANCE FILTERS — The filters must be replaced as often as necessary to assure good air flow and filtering action.
An important point after buying a device York K5EU090A50A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought York K5EU090A50A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data York K5EU090A50A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, York K5EU090A50A you will learn all the available features of the product, as well as information on its operation. The information that you get York K5EU090A50A will certainly help you make a decision on the purchase.
If you already are a holder of York K5EU090A50A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime York K5EU090A50A.
However, one of the most important roles played by the user manual is to help in solving problems with York K5EU090A50A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device York K5EU090A50A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center