Instruction/ maintenance manual of the product M3000-40C Yamaha
Go to page of 48
Owner’ s Manual Mode d’emploi Bedienungsanleitung M MIXING CONSOLE.
2 Introduction Thank you for pur chasing the Y amaha M3000 mixing console. The M3000 is based on Y amaha ’ s experience with the PM ser ies, and features superb sound quality w ith a full range of functionality such as V CA faders, sc ene memor y , and GA di versity .
3 Contents Features of the system ...............................5 Control panel............................................ 6 Input channel section ................................................ 6 Variable/fixed select section......................
4 Precautions • Connect the mix er powe r cord only t o the power supply unit, and connect the po wer supply unit to an A C outlet of the ty pe stated in this Ow ner’ s M anual or as marked on the power supply unit. Failure to do so is a fir e and electrical shock hazard.
5 Features of the system • The M3000-40C pr ovides a generous number of input modules; 40 monaural and 4 stereo (the M3000-24 provides 24 monaural and 4 stereo).
6 Control panel Input channel section Mono input channels The M3000-24 provides 24 input channels, and the M3000-40C provides 40 input channels. All input channels hav e the same specifications. A Phantom pow er s witch/ +48 V indicator This switch turns the +48 V phantom powe r on/off for each channel.
Control panel 7 I M1–M8 s witches These switch on/off the signal which is sent from the input channel to MIX buses 1–8. J M1–M8 mix le v el controls These controls send the signal fr om the input channel to MIX buses 1–8. W hen the c ontrol is in the “ ▲ ” position, the level is nominal (0 dB).
Control panel 8 Q ST (stereo) s witch W hen this switch is on, the signal of the input channel will be sent to the (ST) stereo bus. R PA N control This sets the panning of the signal that is sent from the input channel to the ST bus.
Control panel 9 U VCA GROUP select s witches These switches select the V CA master fader(s) which will control the signal output level of this channel. W hen you select a V CA group 1–8, the indicat or located at the left of each sw itch will light, and the corresponding V CA master fader (V CA master section 3 ) will control the channel.
Control panel 10 Stereo input channels The M3000 provides four ster eo input channels. Ste- reo sound sourc es such as sub-mix ers, effect proces- sor , or CD play ers can be input to the INPUT A jacks (XLR connect ors) or INPUT B jacks (RCA phono connect ors) located on the rear panel.
Control panel 11 G M1–M8 mix le vel controls These controls c ombine the stereo signal fr om the ste- reo input channel int o a mono signal, and send it to MIX buses 1–8. W hen the contr ol is in the “ ▲ ” posi- tion, the level is nominal (0 dB).
Control panel 12 N ST (stereo) s witch W hen this switch is on, the signal of the input channel will be sent to the (ST) stereo bus. O BA L (balance) control This sets the left/right balance of the sig nal that is sent from the input channel t o the ST bus.
Control panel 13 V ariable/fixed select section The M3000’ s GA (Group/A ux) div ersity function allows MIX buses 1–8 to function either as gr oup buses or as A UX buses. In this section, y ou can switch each pair of MIX buses (1/2, 3/4, 5/6, 7/8) between functioning as group buses or as A UX buses.
Control panel 14 Mix section These output channels contr ol the signals of MIX buses 1–16. MIX buses 13/14 and 15/16 are c ontrolled as stereo pairs r espectively .
Control panel 15 MIX buses 1–8 MIX buses 9–12 MIX buses 13–16 (SUB)(ST) from INPUT MIX 3-4, 5-6, 7-8: Same as MIX 1-2 MIX 2: Same as MIX 1 to Meter VARIABLE FIX AFL PFL LR O N MAS AFL MAS (MIX) .
Control panel 16 VCA master fader section The V CA mast er fader section allows the gain of input channels assig ned to a V CA g roup to be contro lled as a whole by the co rresponding V CA fader .
Control panel 17 A T O MA TRIX s witch W hen this switch is on ( ), the ST OUT A post- fader signal is sent to the matrix. B ON/EDIT s witch The function of this switch and indicator will depend on the mode of the M3000. ● In normal mode The ON/EDIT switch will turn ST OUT A on/off.
Control panel 18 STEREO B section This section controls the signal which is output fr om the rear panel ST OUT B jacks (page 28) A LEVEL control This controls the output lev el of the signal which is sent from the ST OUT B jacks. It does not affect the signal which is output from the ST OUT A jacks.
Control panel 19 Monitor section In this section y ou can select the signal which will be monitored fr om the MONIT OR OUT jacks and the PHONES jack. The following signals can be selected as monitor sourc es.
Control panel 20 G LEVEL control This control adjusts the lev el of the signal which is output from the MONIT OR OUT jacks. It does not affect the PHONES jack. H ON s witch This is an on/off switch for the signal which is output from the MONIT OR OUT jacks.
Control panel 21 T alkback section A M1–M2 s witch B M3–M4 s witch C M5–M6 s witch D M7–M8 s witch E M9–M12 s witch F M13–M16 s witch G ST s witch These switches send the talkback or test tone oscillat or signal to MIX buses 1–2, MIX buses 3–4, MIX buses 5–6, MIX buses 7–8, MIX buses 9–12, MIX buses 13– 16, or the ST bus.
Control panel 22 Meter select section In this section y ou can select the source whose lev el will be shown in the meter bridge section. Only one of the sources 1 – 3 can be select ed. A M1–M8 s witch W hen this switch is turned on, the M1/M9/ MA TRIX1–M8/M16/MA TRIX8 meters (page 25) will show the output levels of MIX OUT 1–8.
Control panel 23 A UTILITY s witch Pr ess this switch t o enter U tility mode, where y ou can make settings for scene memories and MIDI, etc. W hen you are in U tility mode, the indicat or located abov e the switch will lig ht. B RECALL s witch U se this switch to recall sc enes from scene memory .
Control panel 24 Matrix section The M3000 provides eight matrices which allow output signals from the MIX buses 1–16 or the ST bus, or input signals from MA TRIX SUB IN to be mixed at the desir ed level.
Control panel 25 Meter bridge A M1/M9/MA TRIX1–M8/M16/MA TRIX8 lev el meters As selected b y the switch settings of the METER SEL section (page 22), these meters indicate the output levels of MIX OUT 1–8/MIX OUT 9–16/MA TRIX OUT 1–8. Each meter has a PEAK indicat or which lights 3 dB before peak level.
26 Rear panel Mono input channel input/out- put jacks A INPUT jacks These are XLR -3-31 t y pe input jacks (balanced). N ominal input level is –16 dB ~ –60 dB when the 26 dB pad switch (page 6) is off, or +10 dB ~ –34 dB when the pad switch is on.
Rear panel 27 Master section input/output jacks F MIX INSERT I/O jac ks These are TRS phone jacks for inserting external sig- nal processors int o MIX buses 1–16. Nominal input/ output level is 0 dB. Pin wiring is as follows. G STEREO INSERT I/O jac ks These are TRS phone jacks for inserting external sig- nal processors int o the ST bus.
Rear panel 28 L ST OUT A/B jacks These are XLR output jacks (balanced) for outputting the signals from the STEREO A/B sections. N ominal output level is +4 dB for both sections. Pin wiring is as follows. M MONIT OR OUT jacks These are XLR output jacks (balanced) for monit or- ing the monitor sourc e selected on the contr ol panel.
Rear panel 29 U MIDI IN/OUT/THRU connectors These are standard fiv e-pin MIDI connect ors. B y c on- necting a sequencer or personal c omput er t o these c on- nectors, you can select sc enes remotely , or backup sc ene memories.
30 About the GA Diversity functionality The GA Div ersity functionalit y of the M3000 allows you t o switch the MIX buses 1–8 between acting as group buses (output level from the input c hannels will be fixed) or acting as A UX buses (output level from the input channels will be variable).
31 About the Scene Memor y function What is scene memor y? Scene memory is a function which stores the on/off status of the mono/stereo input channels and of MIX buses 1–12, 13/14, 15/16 and ST A as one of 128 “sc enes. ” A scene that has been stor ed can be recalled instantly at a touch of a sw itch.
About the Scene Memory function 32 Operations in normal mode Storing a scene (normal mode) 1. Mak e sure that the M3000 is in normal mode, and use the ON/EDIT s witches of the mono/ste- reo input channels, the mix section and the STE- REO A section to make the desired on/off settings.
About the Scene Memory function 33 Operations in check mode In check mode y ou can verify the settings of a scene before recalling it, or edit the on/off status of the ON/ EDIT keys without affecting the internal audio sig- nals. T o mov e from normal mode to check mode, press the CHECK switch in the scene memory section.
About the Scene Memory function 34 Operations in utility mode In utility mode you can modify various settings related t o scene memory oper ations. Operations such as Bulk Out and Bulk Dump R equest are also per - formed in this mode. Basic operation in utility mode 1.
About the Scene Memory function 35 responding pr ogram change message will be tr ansmit- ted. If this is set to “ ” (local), the co rresponding program change will be tr ansmitted even when y ou select a scene for which data has not been sa v ed, th us allowing you t o select pr ograms on an external device.
About the Scene Memory function 36 • If the CC (control change) parameter of utility mode is set to “ ” (m ute group), only control change numbers (105–112) which correspond to mute groups will be tr ansmitted or received.
About the Scene Memory function 37 Adding/defeating mute groups 1. Store the channel or b us mute settings that y ou wish to use as a mute group in a memory num- ber 1–8. 2. In utility mode , select the oP (recall operation) item, and s witch the displa y to “ .
38 About the VCA functionality The V CA master section of the M3000 contains eight V CA master faders. These V CA master faders 1–8 can be used to contr ol the overall input lev el of input channels assigned to the corresponding V CA groups 1–8.
About the VCA functionality 39 Using two or more VCA master faders to control a single channel As the opposite of the example on the previous page, it is also possible to assign a channel to tw o or more V CA g roups. The following diagram shows an exam- ple of signal flow when channel 1 is assigned to V CA groups 1, 5, and 8.
About the VCA functionality 40 • If the V CA MUTE switch of a V CA master fader is turned on (the indicator beside the switch will light), the post-fader signal of all input channels assigned to that V CA g roup will be muted. This is con v enient when you wish to simultaneously mut e or un-mute multiple channels without operating the faders.
41 Error messages One of the following error messages may appear in the MEMOR Y displa y while operating the M3000 or when the power is turned on. If this occurs, refer to the following explanations and take the appr opriate action. (* is an error number) An error occurred while receiving MIDI data.
42 Specifications General specifications 0 dB is referenced to 0.775 Vr ms. T otal Har monic Distor tion Less than 0.1% (THD+N) (Master output) 20 Hz–20 kHz @ +14 dB 600 Ω Less than 0.
Specifications 43 Input/output characteristics Input specifications • 0 dB=0.775 Vrms. *1 XLR connectors are balanced. *2 XLR connector is unbalanced. *3 Phono Jac ks are unbalanced. *4 SUB IN Phone Jac ks(TRS) are unbalanced(T=SIGNAL, R=GND , S=GND).
Specifications 44 Other Connector wiring DC POWER INPUT VCA EXTERNAL I/O Included items P ow er supply connection cable (3 m, 10 pin) Pin No. Signal name 1 P ow er supply remote 2 +15 V 3 ± 15 V GND 4 +48 V GND 5 –15 V 6 +12 V 7 +12V GND/ power supply remote 8 P ow er supply remote 9 +48 V 10 FRAME GND Pin No.
45 D: 874 H: 265 W: 2043/40ch W: 1515/24ch Units: mm Dimensions.
46 MIDI data format 1. MIDI Channel The same channel is used for transmission and recep- tion. Select from channel numbers 1–16. 2. MIDI Program Change Pr ogram change numbers 0–127 correspond to Sc ene M emor y numbers 1–128. This correspondence can- not be changed.
47 IDI Implementation Char t M YAMAHA [MIXING CONSOLE] Date:Apl/08, 1998 Model : M3000 MIDI Implementation Chart Version : 1.0 Function... Transmitted Recognized Remarks Basic Default 1 - 16 1 - 16.
V302330 R2 1 AP 148 NP Printed in T aiwan Y AMAHA CORPORA TION Pro A udio Di vision, #18/3 P .O . Box 3, Hamamatsu, 430-8651, J apan.
An important point after buying a device Yamaha M3000-40C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Yamaha M3000-40C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Yamaha M3000-40C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Yamaha M3000-40C you will learn all the available features of the product, as well as information on its operation. The information that you get Yamaha M3000-40C will certainly help you make a decision on the purchase.
If you already are a holder of Yamaha M3000-40C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Yamaha M3000-40C.
However, one of the most important roles played by the user manual is to help in solving problems with Yamaha M3000-40C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Yamaha M3000-40C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center