445-0215-01-01 Printed in China
t 1-800-670-0707 (toll free) t 604-422-2777 f 604-420-2145 e customerservice@xantrex.com

400 PLUS model shown

400 Plus, 700 Plus
Owner’s Manual

electronics and controls with products from 50 watt mobile units to 1 MW utility-
products include inverters, battery chargers, programmable power supplies, and
variable speed drives that convert, supply, control, clean, and distribute electrical
Other trademarks, registered trademarks, and product names are the property of
scale systems for wind, solar, batteries, fuel cells, microturbines and backup
power applications in both grid-connected and standalone systems. Xantrex
their respective owners, and are used herein for identification purposes only.
Xantrex Technology Inc. is a world-leading supplier of advanced power
XPower is a trademark of Xantrex International. Xantrex is a registered
XPower 175 Plus, 400 Plus, 700 Plus Inverter Owner’s Manual ©
December 2002 Xantrex International reserved.
trademark of Xantrex International.
power.
About Xantrex · Trademarks

CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF
THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK.
SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN
MANUALS OR OTHER DOCUMENTATION PROVIDED BY IT IN CONNECTION
b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES,
a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR
SPECIFICALLY AGREED TO BY IT IN WRITING, XANTREX
December 2002, Revision 1
SUCH INFORMATION.





Thank you for purchasing an XPower Plus Inverter. The XPower
175 Plus, XPower 400 Plus, and XPower 700 Plus are part of a family of ultra compact and highly portable power inverters from
directly from a dedicated 12 volt battery (400 and 700 watt only),
years of safe, trouble-free operation, and includes the following
Xantrex Technology Inc., the leader in high-frequency inverter
The XPower employs reliable solid state power electronics for
the XPower efficiently and reliably powers a wide variety of
Connected to the 12 volt outlet in your vehicle, boat, RV, or
automatic features to ensure safe and trouble-free operation:
household AC products such as portable stereos, laptop
computers, TVs, VCRs, and other similar products.
1 Introduction
design.

To get the best performance from your XPower inverter, Xantrex
recommends that you read this guide before connecting and using
the inverter, and then save it for future reference.
This guide contains:

Misusing or incorrectly connecting the XPower may damage the
equipment or create hazardous conditions for users. Read the
Keep children away from the XPower inverter. The
following safety instructions and pay special attention to all
inverter generates the same potentially lethal AC
power as a normal household wall outlet.
Warnings and Cautions
XPower or other equipment.
or loss of life.

of air surround the inverter. During operation, keep it
Do not use the XPower in the presence of flammable
warm, reaching 140° F (60° C) under extended high
power operation. Ensure that at least 2 inches (5 cm)
powered boat, or near propane tanks. Do not use the
XPower in an enclosure containing automotive-type,
batteries, vent explosive hydrogen gas, which can be
The XPower housing may become uncomfortably
away from materials that may be affected by high
fumes or gases, such as in the bilge of a gasoline
lead-acid batteries. These batteries, unlike sealed
ignited by sparks from electrical connections.
temperatures.

Some chargers for small nickel-cadmium batteries can
shavers, and night lights that are plugged directly
be damaged if connected to the XPower. Do not use
chargers display a warning label stating that
rechargeable flashlights, some rechargeable
the inverter with the following appliances:
into an AC receptacle to recharge.
battery terminals.

Do not connect live AC power to the XPower’s AC
outlets. The inverter will be damaged even if it is
Do not connect any AC load, which has its neutral
Failure to follow these safety guidelines may cause personal
injury and/or damage to the XPower. It may also void your
conductor connected to ground, to the XPower.
switched OFF.
product warranty.
wiring.

This section describes the main features of the XPower inverters.
Figure 1 shows the AC panel of the XPower 175 Plus inverter.

Figure 1 AC Panel of XPower 175 Plus


XPower 175 Plus An AC receptacle is located on one end of
appliances with a combined total power consumption of 150
Figure 2 AC Panel of XPower 400 Plus and XPower 700 Plus
Figure 2 shows the AC panel of the XPower 400 Plus and
the XPower 175 Plus. You can plug in any 120-volt
watts or less when the inverter is turned on.
XPower 700 Plus inverters.
AC Outlets

appliances with a combined total power consumption of 320
appliances with a combined total power consumption of 560
FAULT Light The red FAULT light indicates that the inverter
XPower 400 Plus Two AC receptacles are located on one
end of the XPower 400 Plus. You can plug in any 120-volt
XPower 700 Plus Two AC receptacles are located on one
end of the XPower 700 Plus. You can plug in any 120-volt
On/Off Switch When the On/Off switch is on, AC power is
power is present at the outlet and that the XPower is operating
POWER Light The green POWER light indicates that AC
Audible Alarm An audible alarm warns of an impending low
has shut down. Shutdown is caused by low or high battery
voltage, overload, or excessively high temperatures.
watts or less when the inverter is turned on.
watts or less when the inverter is turned on.
available at the outlet.
voltage shutdown.
normally.

ventilation openings on the front and back panels are kept clear.
Figure 3 shows the DC panel of the XPower 175 Plus inverter.
Ventilation Openings To prevent overheating, ensure that the

Figure 3 DC Panel of XPower 175 Plus


100 watts. When the inverter is turned on, the fan may operate momentarily. The ventilation openings should not be covered at
operate only when output power is greater than approximately
Figure 4 DC Panel of XPower 400 Plus and XPower 700 Plus
XPower 400 Plus and XPower 700 Plus units are designed to
Figure 4 shows the DC panel of the XPower 400 Plus and
any time the inverter is operating.
XPower 700 Plus inverters.

400 Plus and XPower 700 Plus, you connect the ring terminals on the power cables to these terminals. To ensure correct polarity,
red must be connected to red and black must be connected to

Figure 5 Lighter Plug Cable
black.

watts, so it is not equipped with cabling terminals and
The XPower 175 Plus can not power loads over 150

Figure 6 Cable for Direct Connection to 12 Volt Battery
can not be run from a 12 volt battery.

connect a separate cable
clamp cable (included).
connect a separate cable
clamp cable (included).
Product Lighter Plug Connection Cable Clamps/Battery
Available - You must
Plus Not Available Available - You must
Figure 6.
Figure 6.
connect a separate lighter
Plus Available - A cable is
the inverter. Figure 5.
Plus Available - You must
plug cable (included).
Figure 5.

For the best performance, place the inverter on a flat surface in a
The XPower must only be connected to a battery that
has a nominal output of 12 volts. It will not operate if
connected to a 6 volt battery and may be damaged if
The XPower 700 Plus can not be powered from the lighter
connected to a battery with 16 volts or more.
socket of a vehicle.
location that is:

Dry Do not allow water or other liquids to splash on
32° F and 104° F (0° C and 40° C) - the cooler the better within this range. Keep the inverter
Well ventilated Allow at least 2 inches (5 cm) of clearance all
around the inverter, and keep the ventilation
Safe Do not install the XPower in a compartment
with batteries or flammable liquids, such as
of dust/dirt This is especially important if the XPower is
Cool Ambient temperatures should be between
gasoline, or explosive vapors.
used in a work environment.
away from heating vents.
openings clear.
the inverter.
Clean and free

hard-wired into it, so you do not need to complete this step.
equipped with the lighter plug (Figure 5) and place the ring
terminals over the two cabling terminals on the back of the
Follow these steps to connect the XPower 175 Plus or XPower
Make sure you connect red to red and black to black,
inverter. (The cabling terminals are shown in Figure 4.))
If you have a XPower 400 Plus, take the power cord
and make sure you screw the nuts on tightly.
vehicle.

connected this way, you can operate loads of any size up to 320
operating normally and that AC power is available at the
You must connect the XPower 400 Plus or XPower 700 Plus
directly to a 12-volt battery if you are going to operate loads
The green POWER light indicates that the XPower is
watts continuously with a XPower 400 Plus and 560 watts
greater than 150 watts continuously. When the inverter is
continuously with a XPower 700 Plus.
lighter socket or a 12 volt outlet.
outlet.

personal metal objects like rings and bracelets do not
Batteries contain corrosive materials and present an
burns, wear protective eyewear and clothing when
electrical shock hazard. To prevent irritation and
you install the inverter or work with the batteries.
Take special care to ensure that metal tools and
Follow these steps to make a direct battery connection:
contact the battery terminals.

Power connections of the 12 volts DC battery to the
XPower must be positive to positive and negative to
A reverse polarity connection (positive to negative)
will blow a fuse in the inverter and may permanently
polarity connection is not covered by your warranty.
(Figure 6) and place the ring terminals over the two cabling
terminals on the back of the inverter. (The cabling terminals
Make sure you connect red to red and black to black,
damage the unit. Damage caused by a reverse
and make sure you screw the nuts on tightly.
are shown in Figure 4.))
negative.

The green POWER light indicates that AC power is available
then fasten the negative (black) clip to the negative battery
at the outlets and that the inverter is operating normally.
post.

This section describes normal operation as well as conditions that
Normal Operation When you connect the inverter to the vehicle’s
voltage decreases. When the XPower senses that the voltage at its
cigarette lighter or directly to the 12 volt outlet and turn on the
power is available at the outlets. You can now plug in your AC
Low Battery Alarm and Shutdown As the battery discharges, its
DC input has dropped to 10.7 volts, it sounds an alarm. If you
volts, the inverter shuts down all loads to save the battery from
ignore the alarm, and the DC input voltage drops below 10.0
This section explains how to operate the XPower 175 Plus,
On/Off switch, the green POWER light illuminates and AC
XPower 400 Plus and XPower 700 Plus most efficiently.
trigger an alarm or automatically shut down the XPower.
further discharge. The red FAULT light comes on.
products and switch them on one at a time.

automatically if it exceeds its safe operating temperature. The red
The XPower is capable of continuously powering most 120-volt
Overload Shutdown If you connect an AC load that is rated too
levels, the XPower shuts down automatically. The red FAULT
system causes the battery voltage to rise to dangerously high
high (see Table 1 on page 30) or a load that draws excessive
surge power, the XPower shuts down. The red FAULT light
High Input Voltage Shutdown If a defective battery charging
AC products with the following power rating maximums:
Over Temperature Shutdown The XPower shuts down
Shutting the Inverter Off
FAULT light comes on.
light comes on.
off first.
comes on.
Operating Normal Loads

Power Rating Surge Rating
The inverter’s AC (“modified-sine wave”) output waveform, is
designed to function similarly to the sine wave shape of utility
XPower 700 Plus 700 watts 560 watts 1000 watts
power. Most AC products correctly rated for the power rating
maximums listed above or less will operate normally with the
XPower 175 Plus 175 watts 150 watts 300 watts
XPower 400 Plus 400 watts 320 watts 600 watts
Inverter 5 minute Max. Power Rating Continuous
Table 1 Power and Surge Ratings
XPower inverter.
Maximum

The power, or wattage, rating of AC loads is the average amount
their power rating when they are first turned on. TVs, monitors,
momentary surge power that is higher than its maximum power
rating, some products rated less than power rating maximum for
operate several AC products at the same time, try first switching
of power they use. Some appliances consume more power than
overload shutdown. If this problem occurs when attempting to
on the inverter with all AC products switched off, then one by
one switch each on, starting with the high surge product first.
and electric motors are some products that have high surge
your inverter may exceed its surge capability and trigger an
requirements at start up. The XPower inverters can supply
Operating Loads With High Surge Requirements

The battery operating time of the XPower depends on the charge
drawn by the AC loads you are operating. With a typical vehicle
Here are some guidelines that will help to preserve your battery:
level of the battery, battery capacity, and the amount of power
discharge cycles, and constantly recharging a vehicle’s
XPower 175 Plus 50 watts CD player 6-8 hours
XPower 400 Plus 100 watts small TV 3-4 hours
XPower 700 Plus 100 watts small TV 3-4 hours
battery, you can expect the following:
Table 1 Battery Operating Times
Appliance Operating · Time · Inverter Load Sample

battery will shorten its life. Therefore, when you are using a
voltage drop that occurs when the engine starts may trigger a
battery if you will be frequently running electrical products
very high current needed for engine starting. They are not
intended for constant deep discharge. Regularly operating
alarm sounds will shorten the life of the battery. Consider
vehicle battery as a power source, start the vehicle every
connecting the XPower to a separate deep discharge type
the XPower from a vehicle battery until the low voltage
turn off the On/Off switch. The inverter draws less than
0.25 amps when the On/Off switch is on and no load is connected, but it will eventually discharge the battery.
hour or two to recharge the battery.
for extended periods of time.
low voltage shutdown.

This section will help you identify the source of most problems
section before contacting Xantrex Customer Service. If you are
unable to solve a problem and need to contact Xantrex, please
If you have a problem with the inverter, please review this
prepare for the call by writing down the following details:
that can occur with the XPower inverter.

Some inexpensive stereo systems have inadequate internal power
supply filtering and buzz slightly when powered by the XPower.
Do not dismantle the XPower. It does not contain any
inverter yourself could result in an electrical shock or
The best solution is to use an audio system with a good quality
user-serviceable parts. Attempting to service the
Common Problems
Buzz in Audio Systems
burn.
filter.

signals. If TV signals are weak, you may see interference in the
The XPower is shielded to minimize interference with TV
form of lines scrolling across the screen. Try one of these
This section describes problems, their symptoms, possible
suggestions to minimize or eliminate the problem:
use shielded antenna cable where possible.
XPower and the TV, antenna, and cables.
their susceptibility to interference.
causes, and specific remedies.
and cables.
Television Interference

The AC load will not operate. No inverter lights are on.
Inverter will run some small loads, but not larger ones.
with reverse DC input polarity. Check connection to battery. The
inverter has likely been damaged
and needs to be repaired. Have the
unit repaired (not covered under
Loose cable connections. Check cables and connections.
Battery is defective. Check battery and replace if
Voltage drop across DC cables. Shorten cables or use heavier
Possible Cause Suggested Remedy
Possible Cause Suggested Remedy
Tighten as required.
warranty).
required.
cables.
The inverter has been connected

XPower modified sine wave output
requires a “true RMS” voltmeter for
cables. Recharge battery. Allow unit
around unit. Locate units in a cooler
continuous operation is required.
For accurate measurement, the
to cool. Improve air circulation
thermal shutdown has occurred. Shorten cables or use heavier
environment. Reduce load if
accurate measurements.
Possible Cause Suggested Remedy
The battery voltage is too low. Recharge the battery.
Possible Cause Suggested Remedy
Measured inverter output is too low.
measure output voltage, resulting
in an apparent reading 5-15 volts
AC voltmeter has been used to
Low voltage shutdown or
Alarm is sounding.
too low.
A standard “average-reading”

consumption is higher than rated. Use a larger battery to make up for
properly. Some chargers are not able to fully
recharge a battery. Make sure that
Use a product with a power rating
less than the inverter’s continuous
the increased power requirement.
The AC load will not operate. The FAULT light is on.
Power dissipation in DC cables. Use shorter/heavier DC cables.
power rating (see Table 1 on
you use a powerful charger.
Possible Cause Suggested Remedy
The battery is old or defective. Replace the battery.
Possible Cause Suggested Remedy
Battery run time is less than expected.
page 30).
The battery is not being charged
The AC product(s) connected are
rated at more than the inverter’s
overload shutdown has occurred.
The AC product power
continuous power rating;

surge capability. Use a product with
cool for 15 minutes. Clear blocked
fan or remove objects covering unit.
Move the inverter to a cooler place.
Reduce load if continuous operation
properly regulated and the battery is
The product exceeds the inverter’s
Switch inverter OFF and allow to
a starting surge power within the
volts. Verify the charging system is
Possible Cause Suggested Remedy
XPower’s capability.
sounding). Recharge battery.
12 volts nominal.
is required.
The AC product(s) connected are
The inverter has overheated due
rated at less than the inverter’s
continuous power rating; high
Battery is discharged (alarm is
shutdown (alarm is sounding).
Input voltage is greater than 15
to poor ventilation and has
starting surge has caused
overload shutdown.

XPower 175 Plus XPower 400 Plus XPower 700 Plus
AC output waveform Modified Sine Wave Modified Sine Wave Modified Sine Wave
range 10–15 volts DC 10–15 volts DC 10–15 volts DC
(nominal) 120 volts AC 120 volts AC 120 volts AC
output power 150 watts 320 watts 560 watts
5 minutes AC output power 175 watts 400 watts 700 watts
surge power 300 watts 600 watts 1000 watts
AC output frequency 60 ± 4 Hz 60 ± 4 Hz 60 ± 4 Hz
0.15 amps 0.20 amps 0.25 amps
Specifications are subject to change without notice.
Table 1 XPower Plus Specifications
Battery drain with no
(at 12 V input)

XPower 175 Plus XPower 400 Plus XPower 700 Plus
(L x W x H) 5 1/8 x 4 1/8 x 2 1/4 in 130 x 105 x 56 mm 5 7/8 x 4 1/8 x 2 1/4 in 149 x 105 x 56 mm 7 1/4 x 4 1/8 x 2 1/4 in 186 x 105 x 56 mm
temperature range 32° F – 104° F 0° C – 40° C 32° F – 104° F 0° C – 40° C 32° F – 104° F 0° C – 40° C
(nominal) 10.7 volts 10.7 volts 10.7 volts
(nominal) 10.0 volts 10.0 volts 10.0 volts
15.0 volts 15.0 volts 15.0 volts
Weight 1 lb 3 oz. 550 grams 1 lb 6 oz. 655 grams 1 lb 14 oz. 900 grams
(maximum) 90% 90% 90%

XPower Plus Inverter. This warranty lasts for a Warranty Period of 1
(one) year from the date of purchase at point of sale to you, the original
Xantrex will, at its option, repair or replace the defective product free of
charge, provided that you notify Xantrex of the product defect within the
performing warranty repair and building replacement products. Xantrex
reserves the right to use parts or products of original or improved design
in the repair or replacement. If Xantrex repairs or replaces a product, its
(“Xantrex”) and covers defects in workmanship and materials in your
establishes the existence of such a defect and that it is covered by this
warranty continues for the remaining portion of the original Warranty
This Limited Warranty is provided by Xantrex Technology, Inc.
Xantrex will, at its option, use new and/or reconditioned parts in
Warranty Period, and provided that Xantrex through inspection
end user customer.
Limited Warranty.

Period or 90 days from the date of the return shipment to the customer,
whichever is greater. All replaced products and all parts removed from
Xantrex covers both parts and labor necessary to repair the product, and
surface freight within the contiguous United States and Canada. Alaska
and Hawaii are excluded. Contact Xantrex Customer Service for details
on freight policy for return shipments outside of the contiguous United
return shipment to the customer via a Xantrex-selected non-expedited
If your product requires troubleshooting or warranty service, contact
your merchant. If you are unable to contact your merchant, or the
merchant is unable to provide service, contact Xantrex directly at:
Phone: 604 422 2777 Toll Free North America: 1 800 670 0707 Fax: 604 420 2145 Email: customerservice@xantrex.com
repaired products become the property of Xantrex.
States and Canada.

Service Centers. Call Xantrex or check our website to see if your product
product or costs related to the removal, installation, or troubleshooting
of the customer’s electrical systems. This warranty does not apply to and
Material Authorization Policy described in your product manual. For
product and the product must not have been disassembled or modified
some products, Xantrex maintains a network of regional Authorized
In any warranty claim, dated proof of purchase must accompany the
Direct returns may be performed according to the Xantrex Return
This Limited Warranty does not cover normal wear and tear of the
Xantrex will not be responsible for any defect in or damage to:
Proof of purchase may be in any one of the following forms:
without prior written authorization by Xantrex.
product at point of sale to the end user, or
equipment manufacturer (OEM) status, or
can be repaired at one of these facilities.
exchanged under warranty

physically damaged or altered, either internally or externally, or
damaged from improper use or use in an unsuitable environment;
LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS,
corrosion, biological infestations, and high input voltage from
GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND
LIABILITIES, EXPRESS OR IMPLIED, STATUTORY OR
its authorized service centers (hereafter “ASCs”);
markings have been defaced, altered, or removed.
warranted by another manufacturer;
lightning strikes; · Product

OPERATION OF LAW, CONDUCT, STATEMENT OR OTHERWISE),
PURPOSE. ANY IMPLIED WARRANTY OF MERCHANTABILITY
PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIOD
IN NO EVENT WILL XANTREX BE LIABLE FOR ANY SPECIAL,
ANY DAMAGE OR INJURY ARISING FROM OR AS A RESULT OF
OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT
WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT
LOSS OR DAMAGE TO PROPERTY, ANY PERSONAL INJURY,
MISUSE OR ABUSE, OR THE INCORRECT INSTALLATION,
REQUIRED UNDER APPLICABLE LAW TO APPLY TO THE
HOWEVER ARISING (WHETHER BY CONTRACT, TORT,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
OTHERWISE IN CONNECTION WITH THE PRODUCT,
INCLUDING WITHOUT RESTRICTION ANY IMPLIED
STIPULATED UNDER THIS LIMITED WARRANTY.
INTEGRATION OR OPERATION OF THE PRODUCT.

exclusion of implied warranties. To the extent you are entitled to implied
warranties under federal law, to the extent permitted by applicable law
warranties or on the duration of an implied warranty or on the limitation
product. Specifically, please note that this power supply is not intended
warranty or representation in connection with any use of the product for
they are limited to the duration of this Limited Warranty. Some states
Please refer to your product user manual for limitations on uses of the
for use in connection with life support systems and Xantrex makes no
If this product is a consumer product, federal law does not allow an
Warranty gives you specific legal rights. You may have other rights
or exclusion of incidental or consequential damages, so the above
limitation(s) or exclusion(s) may not apply to you. This Limited
and provinces do not allow limitations or exclusions on implied
which may vary from state to state or province to province.
Exclusions
such purposes.

Before returning a product directly to Xantrex you must obtain a Return
Material Authorization (RMA) number and the correct factory “Ship To”
address. Products must also be shipped prepaid. Product shipments will
returned without an RMA number clearly marked on the outside of the
When you contact Xantrex to obtain service, please have your operating
packing materials. Please ensure that your product is shipped fully
insured in the original packaging or equivalent. This warranty will
not apply where the product is damaged due to improper packaging.
shipping box, if they are shipped collect, or if they are shipped to the
be refused and returned at your expense if they are unauthorized,
manual ready for reference and be prepared to supply:
wrong location.
When you ship:

Ship the unit prepaid to the address provided by your Xantrex customer
If you are returning a product from outside of the USA or Canada:
In addition to the above, you MUST include return freight funds and are
If you are returning a product to a Xantrex Authorized Service
number is not required. However, you must contact the ASC prior to
fully responsible for all documents, duties, tariffs, and deposits.
returning the product or presenting the unit to verify any return
procedures that may apply to that particular facility.
marked on the outside of the box.
are not acceptable.
service representative.
hours

If the warranty period for your XPower Plus Inverter has expired, if the
purchase is available, your inverter may be serviced or replaced for a flat
contact Xantrex Customer Service for a Return Material Authorization
(RMA) number and follow the other steps outlined in “Return Material
Payment options such as credit card or money order will be explained by
the Customer Service Representative. In cases where the minimum flat
excessive damage, an additional fee will be charged. If applicable, you
conditions of the warranty have not been met, or if no dated proof of
To see the range of products offered by Xantrex, visit our web site at
To return your XPower Plus Inverter for out of warranty service,
will be contacted by Customer Service once your inverter has been
inverter was damaged by misuse or incorrect installation, if other
fee does not apply, as with incomplete inverters or inverters with
Authorization Policy” on page 49.
received.
fee.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.