EN
Xantech logo
Official user manual

Xantech XVCD50

10 pages·529 KB·Switch·PDF·ENDEFRITNLJA
Xantech XVCD50
Table of Contents 32 sections · · · · … ShowHide
Page 1 of the Xantech XVCD50 user manual —
Page 1 · click to enlarge
Page 1
Xantech XVCD50 —      diagram (page 1)
Fig. 1
Xantech XVCD50 —      diagram (page 1)
Fig. 2
Xantech XVCD50 —      diagram (page 1)
Fig. 3

Xantech XVCD50 —    diagram (page 1)
Fig. 4
Xantech XVCD50 —    diagram (page 1)
Fig. 5
Xantech XVCD50 —    diagram (page 1)
Fig. 6
Page 2 of the Xantech XVCD50 user manual — Installation Instructions
Page 2 · click to enlarge
Page 2

Isolated left- and right-channel grounds ensure safety with any bridged

Xantech’s premier product line of XV volume controls are in-wall

matching capability. From one to eight pairs or stereo speakers

may be driven from one stereo power amplifier, using an equal

number of XV volume controls. It maintains correct impedance

matching between the amplifier and the speakers by the use of

instant setting jumpers on the control. This eliminates the need

  • XVC100, XVD100, XVCS100, XVCO100, XVCD100IR, XVCS100IR

Attenuation: 11 steps plus Off; max 42 dB Frequency response: 20Hz-20kHz ±1 dB Speaker Terminals: 16 gauge, Quick Connect (detachable) Mounting: Minimum 20 cu. in. J-box or Mud Ring.

for separate impedance matching components in multi-room

mountable stereo speaker volume control with impedance

Power handling100 Watts continuous, 300 Watts peak
Power handling50 Watts continuous, 150 Watts peak
  • All Models Adjustable impedance matching for up to 8 speaker pairs

Installation requires only a screwdriver and wire strippers.

XVC Series Volume Controls

Fluid, pop-free switching during volume adjustments.

Compatible with 4-, 6-, or 8-ohm speaker systems.

Installation Instructions

Features and Benefits

UL Listed to comply will all local building codes.

  • XVC50, XVD50, XVC50

(1, 2, 4, 8 pairs)

installations.

amplifier.

Page 3 of the Xantech XVCD50 user manual — Installation Requirements
Page 3 · click to enlarge
Page 3

stranded copper speaker wire. For runs longer than 100 feet, we

recommend 14-gauge stranded copper speaker wire. Never use

rated wire (CL-2 or CL-3) for speaker wire installed within a wall.

from the high voltage (120VAC) power lines. Again, consult your

Consult your local building codes to find out what kind of wire is

You will need at the very least, a ⅛” slotted screwdriver, a ¼”

Be sure to observe proper polarity when connecting a system.

Some areas allow the installation of the volume control to be

placed in the same junction box as a high voltage connection

recommended as the speaker wires may pick up interference

connected to the negative wire. Failure to do so will result in

(120VAC) and divided by a low-voltage partition. This is not

Most installations in the United States require a special fire

The positive terminals should always be connected to the

The recommended speaker wire to be used is 16-gauge

local building codes to verify the proper way to install the

positive wire. The negative terminals should always be

slotted screwdriver, wire cutters and wire strippers.

solid-core wire such as aluminum or Romex wire.

poor phasing and possible system malfunctions.

Installation Requirements

required.

product.

Page 4 of the Xantech XVCD50 user manual — Impedance
Page 4 · click to enlarge
Page 4
1. Determine the minimum amplifier impedance (typically either 4or 8-Ohm). This information can usually be found next to the speaker outputs located on the receiver or amplifier. If in doubt,
3. Move to the right of the chart and find the number of speaker pairs that you plan to connect to the volume control.
4. Finally, move up the column to the very top row. This row will provide the jumper setting solution. Change the jumper on the
2. Next, determine the impedance of a single speaker that will be used. Use the left-most column.

8 Ohm 1 PAIR 2 PAIRS 4 PAIRS 8 PAIRS

6 Ohm - 1 PAIR 2 PAIRS 4 PAIRS

4 Ohm - 1 PAIR 2 PAIRS 4 PAIRS

6 Ohm 1 PAIR 2 PAIRS 4 PAIRS 8 PAIRS

4 Ohm 1 PAIR 2 PAIRS 4 PAIRS 8 PAIRS

procedure. Both jumpers must be changed appropriately

Impedance Jumper Settings for Identical

x1 x2 x4 x8

x1 x2 x4 x8

volume control to complete the impedance jumper setting

8 Ohm 1 PAIR 4 PAIR 8 PAIRS -

consult the receiver and/or amplifier instruction manual.

Jumper Settings

Jumper Settings

How to use the impedance jumper setting chart:

Impedance

CHART A8 Ohm Minimum Amplifier
CHART B4 Ohm Minimum Amplifier

(see diagram in Fig. 1)

Impedance

Impedance

Speaker

Speaker

Page 5 of the Xantech XVCD50 user manual — Example 1:
Page 5 · click to enlarge
Page 5
1. Refer to “CHART A”, 8 Ohm Minimum Amplifier. 2) In the first column, find “8 Ohms”. 3) Follow the row to the right until you find “2 PAIR”. 4) Follow the column up to the very top row and find that the jumper setting should be set to “x2” for both volume

volume controls, all driven by a single amplifier rated for 8 Ohm

1. Set your receiver and/or amplifier to the lowest possible volume setting.
2. Turn all the volume controls to maximum volume (up position for slider volume controls, full clockwise position
3. Turn up the receiver and/or amplifier volume setting until you reach the maximum listening level desired.
4. Finally, lower the volume control level. Volume setting is now complete.
1. Gently press the tabs up on all four corners.
3. Replace with the correct color face plate.

Two pairs of 8 Ohm ceiling speakers are to be used with two

2. Lift the face plate off the metal frame and

Installation Tip – Setting the Volume

remove.

minimum safe operating load impedance.

Xantech XVCD50 — Installation Tip – Setting the Volume diagram (page 5)
Fig. 7 · Installation Tip – Setting the Volume
Xantech XVCD50 — Installation Tip – Setting the Volume diagram (page 5)
Fig. 8 · Installation Tip – Setting the Volume

for rotary volume controls).

Changing the Face Plate

controls.

Example 1:

Page 6 of the Xantech XVCD50 user manual —
Page 6 · click to enlarge
Page 6
Xantech XVCD50 —   diagram (page 6)
Fig. 9

Single Zone, Single Speaker Pair

Volume Control Application

Xantech XVCD50 —   diagram (page 6)
Fig. 10

Show 13 more labels / short text on this page
· · · · · · · · · · · ·
Page 7 of the Xantech XVCD50 user manual — Multiple Zone, Single Speaker Pair
Page 7 · click to enlarge
Page 7
Xantech XVCD50 — Multiple Zone, Single Speaker Pair diagram (page 7)
Fig. 11 · Multiple Zone, Single Speaker Pair

Multiple Zone, Single Speaker Pair

Volume Control Application

Page 8 of the Xantech XVCD50 user manual — Note: Applies to Model XVCD100IR, XVCS100IR only
Page 8 · click to enlarge
Page 8
Xantech XVCD50 — Volume Control and IR Receiver Application diagram (page 8)
Fig. 12 · Volume Control and IR Receiver Application

Volume Control and IR Receiver Application

Note: Applies to Model XVCD100IR, XVCS100IR only

Single Zone, Single Speaker Pair

Xantech XVCD50 — Note: Applies to Model XVCD100IR, XVCS100IR only diagram (page 8)
Fig. 13 · Note: Applies to Model XVCD100IR, XVCS100IR only
Page 9 of the Xantech XVCD50 user manual — CB18 Connecting Block (not included)
Page 9 · click to enlarge
Page 9

onto a 4 conductor bus. You can easily connect many home run

- Nine 4-terminal plug-in connectors on a 4-conductor bus.

500 Watts to be used. - Screw terminals handle wire sizes from 24 to 12 gauge.

- Adhesive backed labels are included for attachment to

- High current design allows amplifiers rated as high as

The CB18 provides a convenient way to parallel many wires

leads from volume controls to the output terminals of a main

Xantech XVCD50 — CB18 Connecting Block (not included) diagram (page 9)
Fig. 14 · CB18 Connecting Block (not included)

- One-in eight-out or eight-in one-out capability.

the plug-in terminals so that the speaker lead

CB18 Connecting Block (not included)

connections can easily be identified.

- Dimensions: 11-¼” x 1-¼” x 1-¼”.

The CB18 features the following:

amplifier.

Page 10 of the Xantech XVCD50 user manual — ATTENTION: TO OUR VALUED CONSUMERS
Page 10 · click to enlarge
Page 10

outside of the United States of America, the terms of this warranty apply EXCEPT that You must

such item was not as warranted above and You promptly notify Xantech in writing, Xantech shall

inadequate packing or shipping damage, maintenance or storage, or to other than normal use of

service. The foregoing warranties do not cover reimbursement for labor, transportation, shipping,

replacement. All claims for product shipping damage must be processes within 3 days of receipt

may be expressly provided and authorized in writing by Xantech, Xantech shall not be subject to

any other obligations or liabilities whatsoever with respect to equipment manufactured or sold by

products are not sold online. The warranties on Xantech products are NOT VALID if the products

Xantech Corporation (“Xantech”) warrants to the holder of a valid proof of purchase as the first

end-user purchaser (“You”), its products to be free from defects in materials and workmanship

for the periods specified above from the date of purchase. This limited warranty extends only to

reconditioned/refurbished/pre-owned or new products or parts under this limited warranty. This

earthquake, or any other catastrophic events beyond Xantech’s control, or (g) to product which

sent to Xantech together with proof of purchase, RA number, prepaid and insured to Xantech.

This document is copyright protected. No part of this manual may be copied or reproduced in

Xantech Corporation shall not be liable for operational, technical, or editorial errors/omissions

You for product purchased and used in the United States of America. For product purchased

contact the Xantech authorized distributor in your region for warranty services. Product is not

intended for end user installation. If within the applicable warranty period above You discover

product that has suffered normal cosmetic deterioration (f) to product which shall have been

shall have been subjected to improper operation, connected equipment failure or malfunction,

installer or your distributor for Product covered under this warranty. Covered product must be

packaged, altered, or physically damaged. Products will be inspected upon receipt. Except as

EXPRESSED AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED

To insure that consumers obtain quality pre-sale and after-sale support and service, Xantech

products are sold exclusively through authorized dealers and authorized distributors. Xantech

repair or replace the items at its option. Xantech may elect which remedy or combination of

Xantech, (d) to charges for installation or set up or adjustment of customer controls, (e) to

removal, installation, or other expenses which may be incurred in connection with repair or

by You. A Xantech Return Authorization (RA) must be obtained from Xantech by You, your

sender. Xantech's warranty does not cover Products which have been received improperly

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Freight collect shipments will be refused. Risk of loss or damage in transit is borne by the

subjected to negligence, misuse, abuse, accident, or damage by circumstances beyond

Xantech’s control, including, but not limited to, lightning, flood, electrical surge, tornado,

determine if your Xantech re-seller is authorized, please call Xantech (800) 843 - 5465.

warranty shall not apply (a) to product which shall have been installed by other than an

authorized Xantech installer, (b) to installed product which is not installed to Xantech’s

specifications, (c) to product which shall have been repaired or altered by others than

have been purchased from an unauthorized distributor or an online E-tailer. In order to

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER

remedies to provide in its sole discretion. Xantech may use functionally equivalent

any form without prior written consent from Xantech Corporation.

© 2006 Xantech Corporation, Document #08905078A

Warranty Statement

Installation Instructions, Volume Controls

13100 Telfair Avenue, 2/F Sylmar, CA 91342

made in this document.

ATTENTION: TO OUR VALUED CONSUMERS

(Effective for products sold after July 1, 2006)

Xantech or services rendered by Xantech.

Xantech 5 Year Limited Warranty

Xantech Corporation

Ask about the Xantech XVCD50

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Xantech XVCD50

Be the first to ask — other owners or our team will answer.

Original document

Xantech XVCD50 manual PDF

10 pages·529 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…