KEY FEATURES: ➤ Stainless steel front, top and sides. ➤ Heavy-duty infrared burner, 30,000 BTU/hr. input. ➤ Infinite heat control valve. ➤ Standing pilot ignition system. ➤ Chrome plated trigger grip control handle provides positive positioning of the broiling carriage. Heavy-duty crome plated broiling grid measures 27½"w x 13"d. ➤ Removable full width spillage pan. ➤ ¾" top gas connection and gas pressure regulator. ➤ One year limited parts and labor warranty.
➤ Set of stainless steel wall mount brackets. ➤ Set of four 4" legs with adjustable feet.
DESCRIPTION: Gas infrared salamander broiler, Wolf Model No. RB36A IR. Stainless steel front, top and sides. Heavy-duty infrared burner, 30,000 BTU/hr. input. Infinite heat control valve. Pilot ignition system. Chrome plated trigger grip control handle provides positive positioning of the broiling carriage. Heavy-duty chrome plated broiling grid measures 27½"w x 13"d. Removable full width spillage pan. ¾" top gas connection and gas pressure regulator.
CSA design certified. NSF listed.
Exterior dimensions: 36"w x 19"d x 17½"h.

SPECIFY TYPE OF GAS WHEN ORDERING. SPECIFY ALTITUDE WHEN ABOVE 2,000 FT.

Wolf Range Company Division of ITW Food Equipment Group LLC (800) 366-9653 www.wolfrange.com
Model IRB36

INSTALLATION REQUIREMENTS: 1. A gas pressure regulator sized for this unit is included. Natural Gas 5.0" W.C. Propane Gas 10.0" W.C. 2. Gas line connecting to appliance must be ¾" diameter or larger. If flexible connectors are used, the inside diameter must be the same as the ¾" iron pipe. 3. An adequate ventilation system is required for commer- cial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org When writing, refer to NFPA No. 96. 4. These units are manufactured for installation in accordance with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat- est edition). Copies may be obtained from The American Gas Association, Accredited Standards Committee Z223
@ 400N. Capital St. NW, Washington, DC 20001, or the Secretary Standards Council, NFPA, 1 Batterymarch Park, Quincy, MA 02169-7471. NOTE: In the Commonwealth of Massachusetts All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR. 5. Clearances: Combustible Non-Combustible Rear 0" 0" Sides 2" 0" Bottom 10" 4"

reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.