Table of Contents/Índice 2



Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
Plug into a grounded 3 prong outlet.
Do not use an extension cord.
Do not remove ground prong.
Unplug air conditioner before servicing.
Do not use an adapter.
Use two or more people to move and install air conditioner.
INSTALLATION REQUIREMENTS
Parts supplied Check that all parts are included in parts package.
Assemble the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
I Flat-blade and Phillips screwdrivers
I Drill and ³⁄₃₂ in. or smaller bit
I Tape measure · I Scissors

Electrical Requirements
I Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner.
I Free movement of air to rooms to be cooled.
I A large enough opening for the air conditioner. Installation parts are supplied for double-hung windows.
Electrical Shock Hazard Plug into a grounded 3 prong outlet.
I Adequate wall support for weight of air conditioner. Air conditioner weighs 56 lbs (25 kg) to 80 lbs (36 kg).
Do not use an adapter. Do not remove ground prong.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
In the U.S. only: If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sure air conditioner is grounded. A three-wire, single-phase, 60-Hz, AC-only, electrical supply is required on a separate circuit. A 15-amp time-delay fuse or circuit breaker is required. Copper wire (14 gauge) is required. The fuse size must not exceed the circuit rating specified on the model and serial number label. The model and serial number label is located on the right-hand side of the cabinet. Specific electrical requirements are listed in the chart. Follow the requirements for the type of plug on the power supply cord.
Window opening measurements:
I 26 in. (66 cm) minimum to 38 in. (95.5 cm) maximum opening width.
I 16 in. (40.6 cm) minimum opening height.
Power supply cord plug outlet
I 115 volt (103.5 min. - 126.5 max.)
I 15-amp time-delay fuse or circuit breaker
I 14 gauge copper wiring
B
Recommended ground method
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer's responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer. It is the customer's responsibility:
A. 26 in. (66 cm) minimum B. 16 in. (40.6 cm) minimum
I To contact a qualified electrical installer.
I To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269
Wiring requirements · I 0-12 amperes


Excessive Weight Hazard Use two or more people to move and install air conditioner.
Failure to do so can result in back or other injury.
I Remove and properly dispose of packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry.
I Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner.
I Handle air conditioner with care.
I Be sure your air conditioner does not fall out of the opening during installation or removal.
I The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded outlet.

I Do not block the louvers on the outside of the air conditioner.

Excessive Weight Hazard Use two or more people to move and install air conditioner.

Failure to do so can result in back or other injury.

I Handle air conditioner with care.
I Be sure your air conditioner does not fall out of the opening during installation or removal.
I The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded outlet.
I Do not block the louvers on the front panel.







Electrical Shock Hazard Plug into a grounded 3 prong outlet.
Do not use an adapter. Do not remove ground prong.
Failure to follow these instructions can result in death, fire, or electrical shock.
Top view

Operating your air conditioner properly helps you to obtain the best possible results. This section explains proper air conditioner operation. IMPORTANT:
I Auto - Cools room while it automatically controls fan speed. You cannot change fan speed, but you can adjust temperature by pressing the plus or minus button.
I Cool - Cools room. You can select fan speed by pressing Fan Speed. You can then adjust temperature by pressing the plus or minus button.
I If you turn off the air conditioner, wait at least 3 minutes before turning it back on. This prevents the air conditioner from blowing a fuse or tripping a circuit breaker.
I Fan Only - Only the fan runs. Display shows “FO” (fan only).
I Do not try to operate your air conditioner in the cooling mode when outside temperature is below 65°F (18°C). The inside evaporator coil will freeze up, and the air conditioner will not operate properly.
I Power Saver - Fan runs only when cooling is needed. Fan stops running when the room temperature matches the Temperature control setting.
Because the fan does not circulate the room air continuously, less energy is used, but the room air is not circulated as often. Use Power Saver when you are asleep or away from home.
Digital Control



I Press the plus button to raise the temperature 1º until it reaches 86°F (30°C).

I Press the minus button to lower the temperature 1º until it reaches 64°F (18°C).
To change the temperature display from °F to °C: 1. Turn off the air conditioner. 2. While the air conditioner is off, press and hold down the MODE and FAN SPEED buttons while pressing POWER to turn the air conditioner on. NOTE: Follow these same steps to change the temperature display from °C to °F.

To operate air conditioner with remote control
To set the Timer for a 1- to 24-hour delay until the air conditioner turns off (the air conditioner must be On): 1. Press TIMER. Indicator light will flash.
To set the Timer to turn on the air conditioner, keeping previous settings: 1. Turn off air conditioner. 2. Press TIMER. Indicator light will flash. 3. Press the plus or minus button to change delay time (1 to 24 hours). 4. Press TIMER again or wait 10 seconds. Indicator light will remain on.
To set the Timer to turn on the air conditioner, changing the previous settings: 1. Turn air conditioner on. 2. Adjust MODE to Auto, Cool, Fan Only, or Power Saver. 3. Adjust FAN SPEED to Turbo, High or Low. 4. Adjust temperature between 64°F (18ºC) and 86°F (30ºC). 5. Wait 3 seconds before turning off air conditioner. 6. Press TIMER. Indicator light will flash. 7. Press the plus or minus button to change delay time (1 to 24 hours). 8. Press TIMER again or wait 10 seconds. Indicator light will remain on.
To turn the air conditioner on or off: Press POWER ON/OFF.
To select the mode: Press AUTO COOL, COOL, FAN ONLY, or POWER SAVER.
To clear Timer delay program: NOTE: Air conditioner can be either on or off. Press and hold TIMER for 3 seconds. Indicator light will shut off.
I Auto Cool - fan speed is adjusted automatically.
I Fan Only - fan speed is automatically set at Turbo.
To see the remaining time (in hours): 1. Press TIMER once after it has been programmed. 2. While the display is showing the remaining time, you can press the plus or minus button to increase or decrease the time.
I Cool or Power Saver - you can adjust the fan speed.

To select the fan speed (in Cool or Power Saver mode only): Press TURBO, HIGH or LOW.
Rotary Control


To raise the temperature: Press the up arrow button to raise the temperature 1º until it reaches 86°F (30ºC).
To lower the temperature: Press the down arrow button to lower the temperature 1º until it reaches 64°F (18ºC).
To set Timer for a 1- to 24-hour delay until air conditioner turns off (the air conditioner must be On): 1. Press TIMER. Indicator light on air conditioner will flash.
Push the Exhaust control CLOSED for maximum continuous cooling. Pull the Exhaust control OPEN to allow you to draw stale or smoky air from the room.
To set Timer to turn on air conditioner, keeping previous settings: 1. Turn off air conditioner. 2. Press TIMER. Indicator light on air conditioner will flash. 3. Press the up arrow or down arrow button to change delay time (1 to 24 hours). 4. Press TIMER again or wait 10 seconds. Indicator light on air conditioner will remain on.
I Open - pull to exhaust room air to the outside

To set Timer to turn on air conditioner, changing the previous settings: 1. Turn on air conditioner. 2. Adjust MODE to Auto, Cool, Fan Only, or Power Saver. 3. Adjust FAN SPEED to Turbo, High or Low. 4. Adjust temperature between 64°F (18ºC) and 86°F (30ºC). 5. Wait 3 seconds before turning off air conditioner. 6. Press TIMER. Indicator light on air conditioner will flash. 7. Press the up arrow or down arrow button to change delay time (1 to 24 hours). 8. Press TIMER again or wait 10 seconds. Indicator light on air conditioner will remain on.
Model 1 · Timer

Set FAN SPEED to the desired setting. When the air conditioner is operating at Low Cool, High Cool, or Turbo Cool, the fan circulates air continuously.
Roll the wheel to direct the air right or left. Rotate the whole cartridge to direct air up, down or straight ahead.
I Turbo Cool - for maximum cooling

I High Cool - for normal cooling
I Low Cool - for sleeping comfort
I Fan Only - to move air continuously without cooling
I Power Saver (on some models) - fan runs only when cooling is needed. Fan stops circulating air when the room temperature matches the Temperature control setting.
Because the fan does not circulate the room air continuously, less energy is used, but the room air is not circulated as often. Use Power Saver when you are asleep or away from home. Model 1
When your air conditioner is operating normally, you may hear sounds such as:
I Droplets of water hitting the condenser, causing a pinging or clicking sound. The water droplets help cool the condenser.

I Vibrations or noise due to poor wall or window construction.
I A high-pitched hum or pulsating noise caused by the modern high-efficiency compressor cycling on and off.
Turn the TEMPERATURE control to a mid-setting. Adjust the air conditioner's performance by turning the Temperature control clockwise for maximum cooling. For less cooling, turn the TEMPERATURE control counterclockwise. Experiment to find the setting that suits you best.
Model 2

Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care for your air conditioner properly. Call your local authorized dealer for an annual checkup. Remember… the cost of this service call is your responsibility.
The air filter is removable for easy cleaning. A clean filter helps remove dust, lint, and other particles from the air and is important for best cooling and operating efficiency. Check the filter every 2 weeks to see whether it needs cleaning. NOTE: Do not operate the air conditioner without the filter in place. 1. Turn off air conditioner. 2. Remove air filter by sliding filter out from either side of unit.
Check once or twice a year for paint damage. This is very important, especially in areas near oceans or where rust is a problem. If needed, touch up with a good grade enamel paint. NOTE: To reduce paint damage during the winter, install a heavy- duty cover over air conditioner cabinet. For information on ordering a heavy-duty cover, see “Accessories” section.
Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year. Call your local authorized dealer to schedule an annual checkup. The expense of an annual inspection is your responsibility.

You can solve many common air conditioner problems easily, saving you the cost of a service call. Try the suggestions below to see whether you can solve your problem without outside help.
Air conditioner cycles on and off too much or does not cool.
I The MODE is set to POWER SAVER (on some models). Use Power Saver only when you are away from home or asleep, since the fan does not circulate the room air continuously. Use LOW, HIGH or TURBO for your best comfort.
Air conditioner will not operate.
I The power supply cord is unplugged. Plug into a grounded 3 prong outlet. See “Electrical Requirements.”
I A household fuse has blown or circuit breaker has tripped. Replace the fuse or reset the circuit breaker. Plug into a grounded 3 prong outlet. See “Electrical Requirements.”
I The air conditioner is not properly sized for your room. Check the cooling capabilities of your room air conditioner. Room air conditioners are not designed to cool multiple rooms.
I Depending on model, the Power button has not been pressed or the Fan Speed control is turned to Off. Press POWER button or turn the FAN SPEED control to an active setting.
I The filter is dirty or obstructed by debris. Clean the filter.
I The inside evaporator and outside condenser coils are dirty or obstructed by debris. See “Annual Maintenance.”
I The local power has failed. Wait for power to be restored.
I There is excessive heat or moisture (open container cooking, showers, etc.) in the room. Use a fan to exhaust heat or moisture from the room. Try not to use heat- producing appliances during the hottest part of the day.
Air conditioner blows fuses or trips circuit breakers.
I Too many appliances are being used on the same circuit. Unplug or relocate appliances that share the same circuit.
I The louvers are blocked. Install the air conditioner in a location where the louvers are free from curtains, blinds, furniture, etc.
I Time-delay fuse or circuit breaker of the wrong capacity is being used. Replace with a time-delay fuse or circuit breaker of the correct capacity. See “Electrical Requirements.”
I The outside temperature is below 65°F (18°C). Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 65°F (18°C).
I An extension cord is being used. Do not use an extension cord with this or any other appliance.
I The temperature of the room you are trying to cool is extremely hot. Allow extra time for the air conditioner to cool off a very hot room.
I You are trying to restart the air conditioner too soon after turning the unit off. Wait at least 3 minutes after turning the unit off before trying to restart the air conditioner.
I Windows or doors to the outside are open. Close all windows and doors.
I The Exhaust control is set to OPEN (on some models). Push the Exhaust control CLOSED for maximum cooling.
Air conditioner seems to run too much.
I Depending on model, the Temp/Time or Temperature control is not at a cool enough setting. Adjust the TEMP/ TIME control to a cooler setting by pressing the minus button to reduce the temperature or adust the TEMPERATURE control to a cooler setting by turning the knob clockwise. Set the FAN SPEED control to TURBO or TURBO COOL.
I The current air conditioner replaced an older model. The use of more efficient components may cause the air conditioner to run longer than an older model, but the total energy consumption will be less. Newer air conditioners do not emit the “blast” of cold air you may be accustomed to from older units, but this is not an indication of lesser cooling capacity or efficiency. Refer to the efficiency rating (EER) and capacity rating (in BTUs/hr.) marked on the air conditioner.
Water drips from cabinet into your house.
I The air conditioner is in a heavily occupied room, or heat- producing appliances are in use in the room. Use exhaust vent fans while cooking or bathing and try not to use heat- producing appliances during the hottest part of the day. A higher capacity air conditioner may be required, depending on the size of the room being cooled.
I The air conditioner is not properly leveled. The air conditioner should slope slightly downward toward the outside. Level the air conditioner to provide a downward slope toward the outside to ensure proper drainage. See the Installation Instructions.

Before calling for assistance or service, please check “Troubleshooting.” It may save you the cost of a service call. If you still need help, follow the instructions below. When calling, please know the purchase date and the complete model and serial number of your appliance. This information will help us to better respond to your request.
Please record your model's information. Whenever you call to request service on your appliance, you need to know your complete model number and serial number. You can find this information on the model and serial number label. See “Electrical Requirements” for model and serial number location. Please record the model and serial number information below. Also, record the purchase date of your appliance and the store's name, address, and telephone number.
If you need replacement parts If you need to order replacement parts, we recommend that you use only factory-authorized replacement parts. These replacement parts will fit right and work right because they are made with the same precision used to build every new appliance. To locate factory-authorized replacement parts in your area, call our Customer Interaction Center telephone number or your nearest designated service center.
In the U.S.A.
Call the Customer Interaction Center toll free: 1-800-253-1301. Our consultants provide assistance with:
Keep this book and the sales slip together for future reference.
I Features and specifications on our full line of appliances.
I Installation information.
I Use and maintenance procedures.
You can order the following accessories for your air conditioner from your local authorized dealer or by calling 1-800-253-1301 from anywhere in the U.S.A.
I Accessory and repair parts sales.
I Specialized customer assistance (Spanish speaking, hearing impaired, limited vision, etc.).
I Referrals to local dealers, repair parts distributors, and service companies. Our service technicians are trained to fulfill the product warranty and provide after-warranty service, anywhere in the United States.
A good, clean air filter is important for best cooling with least energy consumption. Your air filter should be cleaned regularly. See “Cleaning the Air Filter” for cleaning instructions. We suggest you replace your air filter once a year.
To locate the authorized service company in your area, you can also look in your telephone directory Yellow Pages.
For further assistance If you need further assistance, you can write with any questions or concerns at:
If you decide to leave your air conditioner installed during the winter, a heavy-duty cover will help protect your air conditioner and reduce drafts. The outdoor cover protects against cold drafts through the unit's air passages and protects the cabinet from snow, rain, sleet, rust, and dust. For a heavy-duty outdoor cover sized to fit your air conditioner, order Part Number 484184. For a heavy-duty indoor cover sized to fit your air conditioner, order Part Number 4396497.
Customer Interaction Center 553 Benson Road Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.
Owners and our team usually reply within a day — and your question helps the next person too.