
User Manual Guide d’utilisation – OmniView™PRO Serial Manual del usuario para el
OmniView ™ PRO Serial OmniView ™ PRO – Manual
do Usuário


Ca · Es · Po


Thank you for purchasing the Belkin Components OmniView™PRO KVM switch. Controlling 16 PCs from one keyboard, mouse and monitor has never been easier!
The OmniView™PRO gives you the ultimate in control. Compatible with AT and PS/2 style computers, it is loaded with features such as On-Screen Display, Integrated Mouse Conversion Technology and separate DB25 daisy-chain ports. It has complete keyboard and mouse emulation for error-free boot-ups, plus Microsoft®
Intellimouse® support. The OmniView™PRO is also designed to handle the most demanding resolutions up to 1600 x 1200, without any noticeable degradation in image quality. Switching can be done through the advanced On-Screen Display Menu, convenient front-panel pushbutton, or keyboard hot-key commands. And if you wish to control a Macintosh® computer, simply add the Belkin MAC® Adapter™for even more system control. To control a SUN workstation, use a Belkin SUN adapter. The OmniView™
PRO truly gives you ultimate control over all of your systems.

Package Contents:
OmniView™PRO 16-Port F1D116-OSD
12VDC, 1000mA power supply F1D108-PWR
Two rackmount brackets F1D116-BRKT with mounting screws
Four combo mouse adapters F1D116xMSE
This manual P73233 · Registration card P72009

Console Connectors:
Computer Port Connectors:
Keyboard: 6 pin MiniDIN Mouse: 6 pin MiniDIN (combo; PS/2 and serial mouse) Monitor: HDDB15 male
Dimensions:
Weight: 10 lbs. (4.54 kg) est. Operating Temp: 32 to 104 deg. F (0~40 deg. C) Storage Temp: -4 to 140 deg. F (-20 ~ 60 deg. C) Humidity: 0~80% RH, non-condensing


Power Switch Port Select Button Bank Select/Scan Button Current Active Bank Display

The OmniView™PRO requires cables to connect the sixteen computers you will be controlling. Below are the Belkin part numbers and their descriptions. We recommend purchasing Cable Kits based on the type of mouse port your computer uses. One cable kit has all the cables you need to connect one computer to the OmniView™PRO 16- Port:
Includes:


Includes:
A3X982 - PS/2 Cable Kit A3X939 - AT Cable Kit
Individual Cables and Adapters:
5 pin DIN Female
6 pin MiniDIN Male
Other Cables and Adapters:
6 pin MiniDIN DIN Female
5 pin DIN Male
6 pin MiniDIN



BANK 1 (SLAVE)
BANK 2 (SLAVE)
ETC... ETC...
The OmniView™PRO has the capability to be daisy-chained to 15 more units (for a total of 16), giving the user control over a maximum of 256 computers!
Each OmniView™PRO unit is defined as a “BANK.” See diagram above for more information. BANK numbers range from 0 to F (hexadecimal), for a total of 16 BANKs. BANK 0 is the MASTER bank, while banks 1 through F are slave banks. The MASTER bank is the unit that connects to the console keyboard, mouse, and monitor.
The DIP switches must be set correctly for proper identification and usage. See the next section for the actual settings. If you are using the OmniView™PRO in a single-unit configuration, it must be set as the MASTER (BANK 0). If it is to be used as a slave unit, then it must be set to any unused unique bank number from 1 through F.

PLEASE FOLLOW THIS INSTALLATION PROCEDURE EXACTLY. NOT DOING SO MAY RESULT IN KEYBOARD AND/OR MOUSE ERRORS, OR FAULTY OPERATION.
NOTE: “ON” is down 2. Find a convenient place to put your OmniView™PRO. Its 19" form factor makes it ideal for 19" racks. When mounting to a rack, attach the included brackets to the sides of the OmniView™PRO. Take note of the length of your cables so that your computers, OmniView™PRO, keyboard, mouse, and monitor are distanced properly.

Back view of OmniView™PRO
PC15
PC14
PC13
PC12
PC11
PC10
PC9
SW
PC8
PC7
PC6
PC5
PC4
PC3
PC2
PC1


Back view of OmniView™PRO


Back view of OmniView™PRO

If using a serial mouse cable (Belkin Part# F2N209-XX-T), connect the female
end to a DB9 serial port on the computer, and the male end to the DB9 female end of F1D116xMSE combo mouse adapter. Then connect the PS/2 end of the combo mouse adapter to the PC1 PS/2 mouse port on the back of the OmniView™.
PC15
PC14
PC13
PC12
PC11
PC10
PC9
PC1 SW
PC8
PC7
PC6
PC5
PC4
PC3
PC2
Back view of OmniView™PRO
AT KEYBOARD PS/2 MOUSE PS/2 KEYBOARD PARALLEL
AT SERIAL
F2N025-XX-T
PC SERIAL
VGA MONITOR
RJ45 NETWORK
USB 2
USB 1
PC15
PC14
PC13
PC12
PC11
PC10
PC9
AT KEYBOARD PS/2 MOUSE PS/2 KEYBOARD PARALLEL
PC1 SW
PC8
PC7
PC6
PC5
PC4
PC3
PC2
Back of OmniView™ PRO
Back view of OmniView™PRO
PC SERIAL
VGA MONITOR
RJ45 NETWORK
USB 2
USB 1
F2N036-06

Daisy-Chaining the OmniView
The OmniView™PRO can be daisy-chained with additional OmniView™PRO units through the DB25 daisy-chain ports. The F1D108–CBL daisy-chain cable is required (not included) for proper operation. Please refer to the example below. Here, four OmniView™PRO units are cascaded together for control over 64 computers. Recall that a maximum of 16 OmniView™PRO units can be cascaded together for control over 256 computers. Recall that the DIP switches on the MASTER unit must be set to BANK 0, and the slave units set to a unique BANK (any from 1 through F). See the beginning of this section for more information on the DIP switch settings.
PC15
PC14
PC13
PC12
PC11
PC10
PC9
MASTER
PC1 SW
PC8
PC7
PC6
PC5
PC4
PC3
PC2
PC16
PC15
PC14
PC13
PC12
PC11
PC10
PC9
MASTER
PC1 SW
PC8
PC7
PC6
PC5
PC4
PC3
PC2
PC16
PC15
PC14
PC13
PC12
PC11
PC10
PC9
MASTER
PC1 SW
PC8
PC7
PC6
PC5
PC4
PC3
PC2
PC16
PC15
PC14
PC13
PC12
PC11
PC10
PC9
MASTER
PC1 SW
PC8
PC7
PC6
PC5
PC4
PC3
PC2

NOTE: The OmniView™PRO can also be daisy-chained to other OmniView™PRO units (4, 8 or 16 ports) or OmniView SE™units (F1D102 and F1D104 only). This gives the user more selection and flexibility. When doing this, it is desirable to have the OmniView™ PRO as the MASTER unit because of the On-Screen Display (OSD) menu feature. Thus, all the units will benefit from the OSD control, even if the OmniView SE™does not have the OSD feature.

Selecting which computer to operate can be done either by On-Screen Display, the SELECT button, or through keyboard hot-key commands. You will notice that after the OmniView™PRO switches to another computer, the mouse will be inoperative for about 1-2 seconds. This is normal operation and ensures that proper mouse synchronization is established.
The SELECT Button:
Pressing the SELECT button cycles you through all the ports, including inactive ports.
Keyboard Hot key commands:
You can also conveniently command the OmniView™PRO to switch ports through simple keyboard key sequences. To send commands to the OmniView™PRO, the SCROLL LOCK key must be pressed twice within 2 seconds. You will hear a beep for confirmation. Below are the different commands:
Switch to PREVIOUS ACTIVE port (on the same BANK)
Switch to NEXT ACTIVE port (on the same BANK)
Switch to the PREVIOUS BANK (by default, selects first active port on that BANK)
Switch to the NEXT BANK (by default, selects first active port on that BANK)
Directly switches to port Y on BANK X. X = {0 to F} hexadecimal, Y= {1 to G, where ports 10-16 are A-G}
You can switch directly to any port by giving the OmniView™PRO the BANK and PORT numbers. For instance, if you press [SCROLL LOCK] [SCROLL LOCK] [2] [5], the computer on PORT 5 of the OmniView™PRO set to BANK 2 will be selected. In the following diagram, that is PC # 37. Hence, if you only have one OmniView™PRO, the first key (X) must be “0”.

etc...
etc...
AutoScan Mode:
To enable AutoScan mode, press [SCROLL LOCK] [SCROLL LOCK] [0] [0]. In AutoScan mode, the OmniView™PRO remains on one port for a number of seconds, before switching to the next. This time interval is set in the On-Screen Display menu.
To get out of AutoScan mode, press the SPACEBAR.

On-Screen Display Menu Control:
Enable the On-Screen Display Menu
To enable On-Screen Display, press [SCROLL LOCK] [SCROLL LOCK] [SPACEBAR]. Immediately, the OSD overlay screen appears. This screen is generated by the OmniView™PRO, and does not affect your computers or running software in any way.
The main OSD screen menu is shown on the right. It shows the currently selected BANK. If you have only one OmniView™PRO, it will say “BANK 0”.
“✹” Belkin: F1D116-OSD 1. WIN98 ✹ 2. NT SERVER ✹ 3. MAC OS8 ✹ 4. NET SRVR ✹ 5. UNIX SRVR ✹ 6. CHANNEL 6 7. CHANNEL 7 8. CHANNEL 8
A “✹” indicates PC is powered
Currently selected Port is in RED
The current selected port is shown in RED.
A “✹” indicates that the computer connected to that port is powered up.
Currently selected Bank Address
(TAB): FUNCTION / HELP
:PgUp : PgDn
![Page 17 of the Belkin PRO user manual — [ ↕ ]: SELECT (INS): RENAME (Enter):COMPLETE (Esc): Exit](/cdn/reader/b9/b9c7eb7cbb845410f61adf983021cc9e8a3822369fc46e30702c0c0a6a12a973/images/page-17.webp?w=400)
SCAN TIME: Amount of time the OmniView™PRO stays on one port before switching to the next port when in Scan Mode.
SCAN TIME: I 7sec I 15sec I 30sec I 60sec DISPLAY TIME: I 7sec I 15sec I 30sec I 60sec
SCAN TIME: I 7sec I 15sec I 30sec I 60sec DISPLAY TIME: I 7sec I 15sec I 30sec I 60sec
DISPLAY TIME: Amount of time the OSD Menu or Port Name remains displayed on-screen after making a port selection.
[ ↕ ]: SELECT (INS): RENAME (Enter):COMPLETE (Esc): Exit
The BANK/SCAN Button:
Pressing the BANK/SCAN button cycles you through all of the active BANKs (if there are slave units present) and then puts the unit into AutoScan mode. If the unit is a single MASTER unit, pressing the button immediately invokes AutoScan mode. This is evident by a long BEEP, followed by two short beeps.

General Problems:
Q: The OSD menu does not display a “✹” on a port where a computer is connected
CHANNEL buttons on the front panel. Access the OSD menu again and it should have re-detected all the active ports.
Q: When cascading, the MASTER unit does not see the slave unit(s). A: • Refer to the Hardware Installation section for information on how to properly
Q: I am getting ghosting, shadowing or fuzzy images on my monitor. A: • Check the cables and make sure they are inserted properly.
Q: The computers boot up fine, but the keyboard does not work. A: • Check the cables and make sure they are inserted properly in the correct ports.

PS/2 Mouse Problems at the console or computers:
Q: The mouse is not detected during boot-up. A: • Check the cables and make sure they are inserted properly in the correct ports.
Q: The computers boot up fine, but the mouse does not work. A: • Check the cables and make sure they are inserted properly in the correct ports.
Q: When I switch from one port to another, mouse movement is completely erratic. A: • RESET the OmniView™PRO by simultaneously pressing the BANK/SCAN and
Q: The computers boot up fine, but the mouse does not work. A: • Check the cables and make sure they are inserted properly in the correct
ports/adapters. • Check the cable and make sure that it is a straight-through DB9 male/female cable such as Belkin P/N F2N209–XX-T (XX is the length in feet).

Q: When I switch from one port to another, mouse movement is completely
Q: The wheel on the IntelliMouse® does not work on my computer. Why? A: • The Integrated Mouse Conversion Technology converts only the standard PS/2
signals which are the buttons and the x and y coordinate movement, but not the wheel movement or wheel button. This is because the wheel and wheel button data use non-PS/2 protocol.

FCC Statement
DECLARATION OF CONFORMITY WITH FCC RULES FOR ELECTROMAGNETIC COMPATIBILITY
We, Belkin Components, of 501 West Walnut Street, Compton CA 90220, declare under our sole responsibility that the product:
F1D116-OSD to which this declaration relates: Complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
We, Belkin Components, declare under our sole responsibility that the F1D116-OSD, to which this declaration relates, is in conformity with Generic Emissions Standard EN50081-1 and with Generic Immunity Standard EN50082-1 1992.
Belkin Components warrants this product against defects in materials and workmanship for one year. If a defect is discovered, Belkin will, at its option, repair or replace the product at no charge provided it is returned during the warranty period, with transportation charges prepaid, to the authorized Belkin dealer from whom you purchased the product. Proof of purchase may be required.
This warranty does not apply if the product has been damaged by accident, abuse, misuse, or misapplication; if the product has been modified without the written permission of Belkin; or if any Belkin serial number has been removed or defaced.
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE IN LIEU OF ALL OTHERS, WHETHER ORAL OR WRITTEN, EXPRESSED OR IMPLIED. BELKIN SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
No Belkin dealer, agent, or employee is authorized to make any modification, extension, or addition to this warranty.
BELKIN IS NOT RESPONSIBLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPROGRAMMING, OR REPRODUCING ANY PROGRAM OR DATA STORED IN OR USED WITH BELKIN PRODUCTS.
Some states do not allow the exclusion or limitation of incidental or consequential damages or exclusions of implied warranties, so the above limitations of exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
Belkin Components B.V.
© 2000 Belkin Components. All rights reserved. All trade names are registered trademarks of the respective manufacturers listed.
Belkin Components
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.