Page 2 of the Whirlpool Dryer (8535899) user manual — You will need
Page 2 · click to enlarge
Page 2

INSTALLATION INSTRUCTIONS

I A level floor with a maximum slope of 1 in. (2.5 cm) under entire dryer. (If slope is greater than 1 in. [2.5 cm], install Extended Dryer Feet Kit, Part No. 279810.) Clothes may not tumble properly and models with automatic sensor cycles may not operate correctly if dryer is not level.

Tools and Parts

Check that you have everything necessary for correct installation. Proper installation is your responsibility.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

I Tin snips (new vent installations)

I Adjustable wrench that opens to 1 in. (2.5 cm) or hex-head socket wrench (for adjusting dryer feet)

I Caulking gun and compound (for installing new exhaust vent)

I #2 Phillips screwdriver

I Wire stripper (direct wire installations)

Installation Clearances The location must be large enough to allow the dryer door to open fully. Dryer Dimensions

Parts supplied: Remove parts package from dryer drum. Check that all parts were included.

Parts needed: Check local codes. Check existing electrical supply and venting and see “Electrical Requirements” and “Venting Requirements” before purchasing parts. Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For further information, please reference the “Assistance or Service” section of your “Dryer User Instructions.”

Location Requirements

1. Small Opening Side-Swing Door
2. Large Opening Side-Swing Door 3. Wide Opening Side-Swing Door 4. Wide Opening Hamper Door

* Most installations require a minimum 5½ in. (14 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.” Minimum installation spacing for recessed area or closet installation The dimensions shown following are for the minimum spacing allowed.

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

I Additional spacing should be considered for ease of installation and servicing.

You will need

I A location that allows for proper exhaust installation. See “Venting Requirements.”

I Additional clearances might be required for wall, door and floor moldings.

I A separate 30 amp circuit.

I Additional spacing of 1 in. (2.5 cm) on all sides of the dryer is recommended to reduce noise transfer.

I A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See “Electrical Requirements.”

I For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

I A sturdy floor to support the total weight (dryer and load) of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered.

Show 7 more labels / short text on this page
I Flat-blade screwdriver · I Safety glasses · I Level · I Gloves · I Vent clamps · 4 leveling legs · Explosion Hazard
Page 3 of the Whirlpool Dryer (8535899) user manual — It is your responsibility
Page 3 · click to enlarge
Page 3

I Companion appliance spacing should also be considered.

If using a power supply cord: Use a UL approved power supply cord kit marked for use with clothes dryers. The kit should contain:

Whirlpool Dryer (8535899) — Electrical Requirements diagram (page 3)
Fig. 1 · Electrical Requirements

I A UL approved 30 amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

I A UL approved strain relief.

If your outlet looks like this:

1. Recessed area
2. Side view - closet or confined area 3. Closet door with vents

Then choose a 4-wire power supply cord with ring or spade terminals and UL approved strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have 4, 10 gauge solid copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover. If your outlet looks like this:

Mobile Home-Additional Installation Requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). Mobile home installations require:

I Metal exhaust system hardware which is available for purchase from your dealer.

I Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

Then choose a 3-wire power supply cord with ring or spade terminals and UL approved strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have 3, No.-10 copper wires and match a 3-wire receptacle of NEMA Type 10-30R. If connecting by direct wire: Power supply cable must match power supply (4-wire or 3-wire) and be:

Electrical Requirements

It is your responsibility

I To contact a qualified electrical installer.

I To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.

I Flexible armored cable or non-metallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.

A copy of the above code standards can be obtained from: National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

I 10 gauge solid copper wire (do not use aluminum).

I At least 5 ft (1.52 m) long.

I To supply the required 3 or 4 wire, single phase, 120/240-volt, 60-Hz., AC-only electrical supply (or 3 or 4 wire, 120/208-volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and ground- ed in accordance with all local codes and ordinances.

I Do not use an extension cord.

I If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Electrical Connection To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equip- ment-grounding terminal or lead on the dryer.

I If local codes do not permit the connection of a cabinet ground connector to the neutral wire, see “Optional 3-wire connection” section.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is proper- ly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

I This dryer is manufactured with a 3-wire, cabinet-ground conductor connected to the NEUTRAL (white or center wire) of the wiring harness at the terminal block.

I Use a 4-wire conductor cord when the dryer is installed in a mobile home or an area where local codes do not permit grounding through the neutral.

4-wire receptacle (14-30R) · 3-wire receptacle (10-30R)

Page 4 of the Whirlpool Dryer (8535899) user manual — Electrical Connection
Page 4 · click to enlarge
Page 4

Electrical Connection

Whirlpool Dryer (8535899) — Electrical Connection diagram (page 4)
Fig. 2 · Electrical Connection

Use a new UL approved 30 amp power supply cord.

Connect neutral wire (white or center wire) to center terminal (silver).

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Failure to do so can result in death, fire, or electrical shock.

Failure to do so can result in death, fire, or electrical shock.

1. Disconnect power. 2. Remove the hold-down screw and terminal block cover.
3. Assemble a ³⁄₄ in. (1.9 cm) UL approved strain relief (UL marking on strain relief) into the hole below the terminal block opening. Tighten strain relief screws just enough to hold the two clamp sections together. Put power supply cord through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position.
Whirlpool Dryer (8535899) — Electrical Connection diagram (page 4)
Fig. 3 · Electrical Connection
4. Now complete installation following instructions for your type of electrical connection: 4-wire (recommended)

3-wire (if 4-wire is not available)

2. External ground connector 3. Center, silver-colored terminal-block screw 4. Hold-down screw location 5. Neutral grounding wire (green/yellow) 6. Hole below terminal block opening

Power Supply Cord · Direct Wire

Page 5 of the Whirlpool Dryer (8535899) user manual — Electrical Connection
Page 5 · click to enlarge
Page 5
2. Remove appliance ground wire (green with yellow stripes) from external ground connector screw. Fasten it under center, silver colored terminal block screw.
If your home hasAnd you will be connecting to:
Whirlpool Dryer (8535899) — Electrical Connection diagram (page 5)
Fig. 4 · Electrical Connection

4-wire receptacle (NEMA Type 14-30R)

A UL listed, 120/ 240 volt minimum, 30 amp., dryer power supply cord*

4-wire connectionPower Supply Cord

4-wire direct A fused disconnect or circuit breaker box*

4-wire connectionDirect Wire

5" (12.7 cm)

3-wire receptacle (NEMA type 10-30R)

A UL listed, 120/ 240 volt minimum, 30 amp., dryer power supply cord*

3-wire connectionPower Supply Cord
1. External ground connector - Dotted line shows

position of NEUTRAL ground wire before being moved to center terminal block screw 2. Center silver-colored terminal block screw 3. Green/yellow wire of harness

3. Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw. 4. Connect neutral wire (white or center wire) of power supply cord under center screw of the terminal block.

3-wire direct A fused disconnect or circuit breaker box*

3-wire connectionDirect Wire
Whirlpool Dryer (8535899) — Electrical Connection diagram (page 5)
Fig. 5 · Electrical Connection

*If local codes do not permit the connection of a frame- grounding conductor to the neutral wire, go to “Optional 3-wire connection” section.

2. Green wire of power supply cord or bare copper wire 3. External ground connector 4. Center silver-colored terminal block screw 5. Neutral wire (white or center wire) 6. Neutral grounding wire (green/yellow)
1. 4-wire receptacle (NEMA type 14-30R)
2. 4-prong plug 3. Ground prong 4. Neutral prong 5. Spade terminals with upturned ends 6. ¾ in. (1.9 cm) UL approved strain relief 7. Ring terminals
5. Connect the other wires to outer terminal block screws. Tighten screws. 6. Tighten strain relief screws. 7. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
1. Remove center terminal block screw.
4-wire connectionDirect Wire

Electrical Connection Options · Go to Section

Page 6 of the Whirlpool Dryer (8535899) user manual — Electrical Connection
Page 6 · click to enlarge
Page 6

Strip 5 in. (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5 in. (12.7 cm). Cut 1¹⁄₂ in. (3.8 cm) from 3 remaining wires. Strip insulation back 1 in. (2.5 cm). Bend ends of wires into a hook shape.

5. Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
6. Tighten strain relief screws. 7. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw. See example below.

3-wire connectionPower Supply Cord

Use where local codes permit connecting cabinet-ground conductor to neutral wire:

Whirlpool Dryer (8535899) — Electrical Connection diagram (page 6)
Fig. 6 · Electrical Connection
1. Remove center terminal block screw. 2. Remove appliance ground wire (green with yellow stripes) from external ground connector screw. Fasten it under center, silver colored terminal block screw.
Whirlpool Dryer (8535899) — Electrical Connection diagram (page 6)
Fig. 7 · Electrical Connection
1. 3-wire receptacle (NEMA type 10-30R)
2. 3-wire plug 3. Neutral prong 4. Spade terminals with up turned ends 5. ³⁄₄ in. (1.9 cm) UL approved strain relief 6. Ring terminals 7. Neutral (white or center wire)
1. Loosen or remove center terminal block screw. 2. Connect neutral wire (white or center wire) of power supply cord to the center, silver colored terminal screw of the terminal block. Tighten screw.
Whirlpool Dryer (8535899) — Electrical Connection diagram (page 6)
Fig. 8 · Electrical Connection
1. External ground connector - Dotted line shows

position of NEUTRAL ground wire before being moved to center terminal block screw 2. Center silver-colored terminal block screw 3. Green/yellow wire of harness

3. Connect ground wire (green or bare) of power supply cable to external ground conductor screw. Tighten screw. 4. Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
Whirlpool Dryer (8535899) — Electrical Connection diagram (page 6)
Fig. 9 · Electrical Connection
1. Neutral grounding wire (green/yellow)
2. External ground connector 3. Center silver-colored terminal block screw 4. Neutral wire (white or center wire) 5. ³⁄₄ in. (1.9 cm) UL-listed strain relief
3. Connect the other wires to outer terminal block screws. Tighten screws. 4. Tighten strain relief screws. 5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
1. ³⁄₄ in. (1.9 cm) UL-listed strain relief
2. Green or bare copper wire of power supply cord 3. External ground connector 4. Center silver-colored terminal block screw 5. Neutral wire (white or center wire) 6. Neutral grounding wire (green/yellow)
Page 7 of the Whirlpool Dryer (8535899) user manual — Electrical Connection
Page 7 · click to enlarge
Page 7
3-wire connectionDirect Wire

Use where local codes permit connecting cabinet-ground conductor to neutral wire. Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed. Strip 3¹⁄₂ in. (8.9 cm) of outer covering from end of cable. Strip insulation back 1 in. (2.5 cm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Bend ends of wires into a hook shape.

Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire. 1. Remove center terminal block screw. 2. Remove appliance ground wire (green with yellow stripes) from external ground connector screw. Connect appliance ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver colored terminal block screw. Tighten screw. 3. Connect the other wires to outer terminal block screws. Tighten screws.

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw.

4. Tighten strain relief screws. 5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 6. Connect a separate copper ground wire from the external ground connector screw to an adequate ground.
1. Loosen or remove center terminal block screw. 2. Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
Whirlpool Dryer (8535899) — Electrical Connection diagram (page 7)
Fig. 10 · Electrical Connection
Whirlpool Dryer (8535899) — Electrical Connection diagram (page 7)
Fig. 11 · Electrical Connection
1. Neutral grounding wire (green/yellow)
2. External ground connector 3. Center silver-colored terminal block screw 4. Neutral wire (white or center wire) 5. ³⁄₄ in. (1.9 cm) UL-listed strain relief
1. External ground connector
2. Neutral grounding wire (green/yellow) 3. Neutral wire (white or center wire) 4. Grounding path determined by a qualified electrician
3. Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
4. Tighten strain relief screws. 5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

Optional 3-wire connection

Page 8 of the Whirlpool Dryer (8535899) user manual — Standard exhaust installation with rigid metal or flexible metal vent
Page 8 · click to enlarge
Page 8

Venting Requirements

Plan Vent System

Whirlpool Dryer (8535899) — Venting Requirements diagram (page 8)
Fig. 12 · Venting Requirements

Typical exhaust installations Typical installations vent the dryer from the rear of the dryer.

Whirlpool Dryer (8535899) — Venting Requirements diagram (page 8)
Fig. 13 · Venting Requirements

Failure to follow these instructions can result in death or fire.

1. Dryer
5. Clamps
2. Elbow 3. Wall 4. Exhaust hood
6. Rigid metal or flexible metal vent 7. Vent length necessary to connect elbows 8. Exhaust outlet

4 in. (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended. DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the “Assistance or Service” section of your “Dryer User Instructions.”

Standard exhaust installation with rigid metal or flexible metal vent

I The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, or a concealed space of a building.

I Do not use an exhaust hood with a magnetic latch.

I Do not install flexible metal vent in enclosed walls, ceilings or floors.

I Use clamps to seal all joints. Exhaust vent must not be connected or secured with screws or other fastening devices which extend into the interior of the duct. Do not use duct tape.

Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions.

Whirlpool Dryer (8535899) — Standard exhaust installation with rigid metal or flexible metal vent diagram (page 8)
Fig. 14 · Standard exhaust installation with rigid metal or fl…
Whirlpool Dryer (8535899) — Standard exhaust installation with rigid metal or flexible metal vent diagram (page 8)
Fig. 15 · Standard exhaust installation with rigid metal or fl…

Improper venting can cause moisture and lint to collect indoors, which may result in:

Use a heavy metal vent. Do not use plastic or metal foil vent. Rigid metal vent is recommended to prevent crushing and kinking. Flexible metal vent must be fully extended and supported when the dryer is in its final position. Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance. An exhaust hood should cap the vent to prevent rodents and insects from entering the home. Exhaust hood must be at least 12 in. (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, etc.). If using an existing vent system, clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint. Replace any plastic or metal foil vent with rigid metal or flexible metal vent.

1. Over-The-Top installation (also available with one offset elbow) 2. Periscope installation

I Over-The-Top Installation:

Part Number 4396028

Page 9 of the Whirlpool Dryer (8535899) user manual — Vent Length Chart
Page 9 · click to enlarge
Page 9

I Periscope Installation (For use with dryer vent to wall vent mismatch):

Exhaust systems longer than specified will:

I Shorten the life of the dryer.

Part Number 4396037 - 0 in. (0 cm) to 18 in. (45.72 cm) mismatch

I Reduce performance, resulting in longer drying times and increased energy usage.

Part Number 4396011 - 18 in. (45.72 cm) to 29 in. (73.66 cm) mismatch

3. Determine the number of elbows you will need. NOTE: Do not use vent runs longer than specified in the Vent Length Chart.

Part Number 4396014 - 29 in. (73.66 cm) to 50 in. (127 cm) mismatch

When using only one type of metal vent:

Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Use the following chart to help you determine your maximum vent length based on the number of 90° turns or elbows you will need and the type of vent (rigid and/or flexible metal) you will use.

Vent Length Chart

Number of 90º turns or elbows

Rigid metal vent Flexible metal vent

0 120 ft (36.6 m) 40 ft (12.2 m)

1 110 ft (33.5 m) 37 ft (11.3 m)

2 100 ft (30.5 m) 33 ft (10.1 m)

3 90 ft (27.4 m) 30 ft (9.1 m)

Determine Vent Length 1. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90º turns.

4 80 ft (24.4 m) 27 ft (8.2 m)

5 70 ft (21.3 m) 23 ft (7.0 m)

When using a combination of rigid and flexible metal vent:

Use the following charts to help you determine your maximum vent length based on the number of 90° turns or elbows you will need.

I Determine the number of elbows or turns you will need.

I Determine the length of the fully extended flexible metal vent you will use. Find the column that has the nearest number of feet to what you will be using.

2. Determine vent length. The maximum length of the exhaust system depends upon:

I Match the number of turns or elbows with the length of the fully extended flexible metal vent you will use to find the maximum length of rigid metal vent you can use.

I The type of vent (rigid metal or flexible metal).

I The number of elbows used.

I If a combination of rigid and flexible metal vent is used.

Vent Length Chart - 0 ft (0 m) to 10 ft (3.0 m)

Recommended hood styles are shown here.

No. of turns or elbows

Length of Flexible Metal Vent

0 ft (0 m)

1-5 ft (.3-1.5 m)

6-10 ft (1.8-3.0 m)

0 120 ft (36.6 m)

105 ft (32.0 m)

90 ft (27.4 m)

4" (10.2 cm)

4" (10.2 cm)

1 110 ft (33.5 m)

95 ft (29.0 m)

80 ft (24.4 m)

1. Louvered hood style 2. Box hood style

Length of Rigid metal vent

2 100 ft (30.5 m)

85 ft (25.9 m)

70 ft (21.3 m)

The angled hood style (shown following) is acceptable.

4" (10.2 cm)

3 90 ft (27.4 m)

75 ft (22.9 m)

60 ft (18.3 m)

4 80 ft (24.4 m)

65 ft (19.8 m)

50 ft (15.2 m)

2½" (6.4 cm)

The same length of vent can be used with any of the 3 exhaust hoods shown.

5 70 ft (21.3 m)

55 ft (16.8 m)

40 ft (12.2 m)

Page 10 of the Whirlpool Dryer (8535899) user manual — Connect Vent
Page 10 · click to enlarge
Page 10

4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible. 5. Place a carton corner post under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent. 6. Once connection is made and dryer is in final location, remove corner posts and cardboard.

Vent Length Chart - 11 ft (3.4 m) to 25 ft (7.6 m)

No. of turns or elbows

Length of Flexible Metal Vent

11-15 ft (3.4-4.6 m)

16-20 ft (4.9-6.1 m)

21-25 ft (6.4-7.6 m)

0 75 ft (22.9 m)

60 ft (18.3 m)

45 ft (13.7 m)

Whirlpool Dryer (8535899) — Install Vent System diagram (page 10)
Fig. 16 · Install Vent System

1 65 ft (19.8 m)

50 ft (15.2 m)

35 ft (10.7 m)

Check the levelness of the dryer. Check levelness first side-to-side, then front-to-back.

Length of Rigid metal vent

2 55 ft (16.8 m)

40 ft (12.2 m)

25 ft (7.6 m)

3 45 ft (13.7 m)

30 ft (9.1 m)

15 ft (4.6 m)

4 35 ft (10.7 m)

20 ft (6.1 m)

5 ft (1.5 m)

If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for levelness. NOTE: It might be necessary to level the dryer again after it is moved into its final position.

5 25 ft (7.6 m)

10 ft (3.0 m)

0 ft (0 m)

Install Vent System

1. (Optional) Put on safety glasses and gloves. 2. Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood. 3. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4 in. (10.2 cm) clamp. 4. Run vent to dryer location. Use the straightest path possible. See “Determine Vent Length.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.

Connect Vent

1. Using a 4 in. (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Make sure the vent is secured to exhaust hood with a 4 in. (10.2 cm) clamp. 2. Move dryer into final position. Do not crush or kink vent. Make sure dryer is level. 3. (On gas models) Check to be sure there are no kinks in the flexible gas line.

Whirlpool Dryer (8535899) — Connect Vent diagram (page 10)
Fig. 17 · Connect Vent

You can change your door swing from a right-side opening to a left-side opening, if desired.

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.

1. To protect the floor, use a large, flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer. See illustration. 2. Firmly grasp the body of the dryer (not the top or console panel).

Gently lay the dryer on the cardboard.

1. Place towel (1) on top of dryer to protect surface. 2. Open dryer door. Remove bottom screws from cabinet side of hinges (3). Loosen (do not remove) top screws from cabinet side of hinges. 3. Lift door until top screws in cabinet are in large part of hinge slot. Pull door forward off screws. Set door on top of dryer. Remove top screws from cabinet.
3. Examine the leveling legs. Find the diamond marking.
Page 11 of the Whirlpool Dryer (8535899) user manual — Complete Installation
Page 11 · click to enlarge
Page 11
4. Use a small, flat-blade screwdriver to carefully remove 4 hinge hole plugs (4) on left side of cabinet. Insert plugs in hinge holes on right side of cabinet. 5. Insert screws in bottom holes on left side of cabinet. Tighten screws halfway. Position door so large end of door hinge slot is over screws. Slide door up so screws are in bottom of slots. Tighten screws. Insert and tighten top screws in hinges.
8. Remove door strike (5) from cabinet. Use a small, flat-blade screwdriver to carefully remove 4 hinge hole plugs (6) on left side of cabinet. Insert plugs in hinge holes on right side of cabinet. 9. Insert screws in bottom holes on left side of cabinet. Tighten screws halfway. Position door so large end of door hinge slot is over screws. Slide door up so screws are in bottom of slots. Tighten screws. Insert and tighten top screws in hinges.
6. Close door and check that door strike aligns with door catch (2). If needed, slide door catch left or right within slot to adjust alignment.
10. Remove door strike plug (2). Insert the door strike you removed in Step 8 in hole and secure with screw. Insert door strike plug in original door strike hole and secure with screw. 11. Close door and check that door strike aligns with door catch (3). If needed, slide door catch left or right within slot to adjust alignment.

Reversible Super Wide Side-Swing Door

Whirlpool Dryer (8535899) — Reversible Super Wide Side-Swing Door diagram (page 11)
Fig. 18 · Reversible Super Wide Side-Swing Door

Complete Installation

1. Check to be sure all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped. 2. Check to be sure you have all of your tools. 3. Dispose of all packaging materials. 4. Check the dryer’s final location. Be sure the vent is not crushed or kinked. 5. Check to be sure the dryer is level. (See “Level Dryer.”) 6. Plug into a grounded outlet. Turn power on. 7. Remove the blue protective film on the console and any tape remaining on the dryer. 8. Read your “Dryer User Instructions.” 9. Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust. 10. Set the dryer on a full heat cycle (not an air cycle) for 20 minutes and start the dryer. If the dryer will not start, check the following:

1. Place towel (1) on top of dryer to protect surface. 2. Open dryer door. Remove bottom screws from cabinet side of hinges (4). Loosen (do not remove) top screws from cabinet side of hinges. 3. Lift door until top screws in cabinet are in large part of hinge slot. Pull door forward off screws. Set door (handle side up) on top of dryer. Remove top screws from cabinet. 4. Remove screws attaching hinges to door. 5. Remove screws at top, bottom and side of door (4 screws). Holding door over towel on dryer, grasp sides of outer door and carefully lift to separate it from inner door. Do NOT pry apart with putty knife. Do NOT pull on door seal or plastic door catches. 6. Be careful to keep cardboard spacer centered between doors. Reattach outer door panel to inner door panel so handle is on the side where hinges were just removed.

I Controls are set in a running or “On” position.

I Start button has been pushed firmly.

I Dryer is plugged into a grounded outlet.

I Electrical supply is connected.

I House fuse is intact and tight, or circuit breaker has not tripped.

I Dryer door is closed.

11. When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you do not feel heat, turn off the dryer and check the following:

I There may be 2 fuses or circuit breakers for the dryer. Check to make sure both fuses are intact and tight, or that both circuit breakers have not tripped. If there is still no heat, contact a qualified technician.

7. Attach door hinges to door so large part of hinge slot is at bottom of hinge.

Ask about the Whirlpool Dryer (8535899)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Whirlpool Dryer (8535899)

Be the first to ask — other owners or our team will answer.

Original document

Whirlpool Dryer (8535899) manual PDF

24 pages·952 KB·Washing Machine·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…