EN
Belkin logo
Official user manual

Belkin IP 5232K

57 pages·5.1 MB·Switch·PDF·ENDEFRITNLJA
Belkin IP 5232K
Table of Contents 80 sections OmniView IP* · 5216K/5232K User Manual · Introduction · Key Features · … ShowHide
OmniView IP*p.15216K/5232K User Manualp.1Introductionp.4Key Featuresp.5System Contentsp.7System Requirementsp.7Terminologyp.8Unit Display Diagramsp.9J<I@8C( J < I )p.9CF:8CLJ<Ip.9MD(p.9Connector tablep.9INSTALLATIONp.10Pre-Installation Guidelinesp.10Avoiding general rack-mounting problemsp.10Rack-mounting the SMB IP KVM Switchp.11Connecting the Systemp.12The Server Interface Modules (SIMs)p.13Setting the IP Addressp.16WEB INTERFACEp.18Logging In to the Web Interfacep.18SSL certificate notesp.18Logging inp.19Connecting to a target serverp.20Network > Configurationp.20Configuring the Systemp.20LANp.21OmniView IP Central Access Appliance 5000HQp.21Administration > User Settingsp.22Administration > Server Name Editp.24Administration > Serial Settingsp.24Administration > Server Access Listp.25Security > Settingsp.26Security > SSL Certificatep.27Maintenance > Switch Upgradep.27Set Time and Datep.29Back Up and Restorep.29Saving Changes and Logging Outp.30Accessing a Target Serverp.31The Toolbarp.32Changing the performance settingsp.32Switching to a different serverp.32Bandwidthp.33Adjusting the video settingsp.33Refreshp.33Manual video adjustp.34Auto video adjustp.35Keyboard key sequencesp.35Red Hat ® , Fedora, and other Linux distributionsp.38Manual settingsp.39Advanced – Mouse emulationp.40Calibrating mice pointersp.41Adjustments in generalp.41Globe icon menu featuresp.42Virtual mediap.43Full-screen modep.45Disconnecting the remote sessionp.45The Targets Page Menup.45Changing the passwordp.46Downloading the logp.46Event logp.46Clearing the logp.46LOCAL ACCESSp.47Navigating the OSD Main windowp.47The OSDp.47Selecting a computerp.47The Settings window – F2p.49DDC – F10p.50Saving changes to the settingsp.50Updating the DDC informationp.50Additional informationp.51Technical Specificationsp.51PS/2 SIM USB SIMp.51VGA - HDD15p.51KM - USBp.51Video Resolution and Refresh Ratesp.52Safetyp.53User Manual Feedbackp.53Product Registrationp.53Informationp.54
Page 1 of the Belkin IP 5232K user manual — OmniView IP*
Page 1 · click to enlarge
Page 1
Belkin IP 5232K — OmniView IP* diagram (page 1)
Fig. 1 · OmniView IP*

OmniView IP*

5216K/5232K User Manual

PM00020 - F1DP2XXG *OmniView is a registered trademark of Belkin International, Inc.

Page 2 of the Belkin IP 5232K user manual — OmniView IP*
Page 2 · click to enlarge
Page 2
Page 2 of the Belkin IP 5232K user manual — OmniView IP*
Page 3 of the Belkin IP 5232K user manual — OmniView IP*
Page 3 · click to enlarge
Page 3
Page 3 of the Belkin IP 5232K user manual — OmniView IP*
Page 4 of the Belkin IP 5232K user manual — Introduction
Page 4 · click to enlarge
Page 4

Introduction

Congratulations and thank you for purchasing the Belkin OmniView IP 5216K/5232K Switch with the latest in IP KVM technology. This Switch provides a simple, quick, remote server management solution for medium to large-size businesses. The Switch allows two remote digital users and one local analog user to access and control your servers over the Internet via a standard web browser.

Combine the Switch with the Belkin Central Access Appliance 5000HQ to address the management and administration needs of more users accessing more servers across geographical locations.

The innovative technology in the OmniView IP 5216K/5232K Switch combines hardware and software technology to deliver high- performance remote access, and enables you to troubleshoot servers faster and more efficiently, reducing server downtime and service costs in mission-critical environments.

Belkin’s distinctive technology provides IT professionals:

  • Immediate video synchronization, allowing access through the entire boot sequence, when troubleshooting is most critical.
  • Immediate video display and keyboard output to intercept systems at their earliest status upon power-up or reboot.
  • Instantaneous access between multiple sessions over IP. Users experience immediate access when switching between attached systems, eliminating the delay when managing time-sensitive system access and repair.

This User Manual provides all the details you’ll need to install and operate your new OmniView IP 5216K/5232K Switch, in addition to expert troubleshooting advice—in the unlikely event of a problem. For quick and easy installation, please refer to the Quick Installation Guide included in your packaging.

We appreciate your business and are confident that you will soon see for yourself why over 1 million Belkin OmniView KVM products are in use worldwide.

Page 5 of the Belkin IP 5232K user manual — Introduction
Page 5 · click to enlarge
Page 5

Introduction

Key Features

  • Access, switch, view, and control faster than before
  • Switch from one remote server to another instantly
  • Quicker performance over the Internet and congested networks
  • View all the information displayed during the post and boot process

Web-Browser Based The Switch allows you to access your KVM switch and all connected servers from any computer connected to the LAN, WAN, or Internet using Firefox® or Microsoft Internet Explorer®.

Out of Band—BIOS-Level Access The Switch allows you to remotely access the basic input/output system (BIOS) of your servers to make changes and perform reboots, regardless of network connectivity or server condition.

User-Friendly Interface The web-based interface allows you to set up and change the Switch’s functions quickly and easily through your web browser, without having to install additional software onto your servers.

Remote Serial Access The Switch provides support for up to two serial devices, such as a managed power distribution unit (PDU), so you can remotely perform hard reboots of your servers.

High-Performance Remote Access

Page 6 of the Belkin IP 5232K user manual — Introduction
Page 6 · click to enlarge
Page 6

Introduction

Virtual-Media Technology The Switch provides virtual-media support for up to two servers. This allows the remote user to copy files from a USB or CD-ROM drive to a target server that may be anywhere in the world. Or boot a remote server from a local USB or CD-ROM drive.

Enhanced Security The IP device provides 128-bit Secure Sockets Layer (SSL) authentication and password protection to prevent unauthorized access to your servers and protect data transferred over the Internet. The data communication is also protected with AES 256-bit encryption.

Scalable Centralized Management Additional Switches can be added as your data center grows and the entire inventory can be managed under the Belkin Central Access Appliance 5000HQ. This is ideal for corporations operating servers at multiple sites such as testing labs, campuses, branch offices, and multi-floor facilities.

Video Resolution The Switch supports video resolutions of up to 1600x1200@75Hz for both local and remote consoles.

Flash-Upgradeable Flash upgrades allow you to obtain the latest firmware updates for your Switch. These firmware updates ensure that the Switch is compatible with the latest devices.

Page 7 of the Belkin IP 5232K user manual — System Requirements
Page 7 · click to enlarge
Page 7

Introduction

System Contents

  • PS/2 and USB computers/servers
  • 1 OmniView IP 5216K/5232K Switch
  • VGA, SVGA, or XGA monitors
  • 1 AC Power Cable
  • 1 Serial-to-RJ45 Interface Cable
  • 1x User Manual CD
  • USB-compatible
  • 1 Quick Start Guide
  • 1 Set Rack-Mount Brackets and Screws
  • CRT and LCD (with VGA, SVGA, or XGA monitors)

System Requirements

Remote-Client Browser The Switch may be accessed remotely over a TCP/IP connection from computers using the following web browsers and OS platforms:

Host Computer Operating-System (OS) Platforms The Switch is compatible with CPUs running on, but not limited to, the following OS platforms:

  • Windows ® 2000, XP, Server 2003 and 2008, Vista ®
  • Microsoft Internet Explorer 6.0 and above with ActiveX ® support
  • Microsoft ® DOS 5.x and above
  • Firefox 3.0 and above**
  • Red Hat ® Linux ® 8.x and above

Linux (major distributions only)

  • Sun™*
  • Firefox 3.0 and above**
  • Novell ® 5.x

**Firefox support may require a firmware upgrade. Visit www.belkin.com/support for more information.

  • Sun Solaris™ 8.x and above*

Server Interface Modules Connecting the Switch to a server requires a custom Belkin OmniView SMB Server Interface Module and a standard CAT5 patch cable.

*USB server interface module required

Show 4 more labels / short text on this page
Servers · Keyboards and Mice · Monitors · Windows
Page 8 of the Belkin IP 5232K user manual — Introduction
Page 8 · click to enlarge
Page 8

Introduction

Terminology

OmniView SMB Server Interface Modules: F1DP101A-AP (PS/2 style) F1DP101A-AU (USB style) F1DP101A-AS (Legacy Sun, miniDIN8 style) F1DP101A-AP-8PK (PS/2 style, 8-pack) F1DP101A-AU-8PK (USB style, 8-pack)

Below are some terms and their meanings used in this guide.

TermMeaning Target serverThe computers/servers that are accessed remotely via the Switch. Client computerThe PC running a remote session. Remote sessionThe process of remotely accessing and controlling target servers connected to the Switch from a user workstation.

CAT5 Cables Belkin highly recommends you use Belkin Category 5e, FastCAT™ 5e, or Category 6 Patch Cables for your OmniView IP 5216K/5232K Switch to help ensure the superior performance of your video. These Cables offer the highest quality possible to ensure optimal data and video transmission.

Belkin UTP Patch CablesA3L791-XX-YYY (CAT5e) A3L850-XX-YYY (FastCAT 5e) A3L980-XX-YYY (CAT6)
Page 9 of the Belkin IP 5232K user manual — Connector table
Page 9 · click to enlarge
Page 9

Introduction

Unit Display Diagrams

J<I@8C( J < I )

CF:8CLJ<I

Figure 1 illustrates the front panel of the OmniView IP 5232K Switch.

MD) GFN<I (''$)+'M8:,'&-'?q

MD(

Figure 2 OmniView IP 5232K Switch – rear view

Connector table

Figure 1 OmniView IP 5232K Switch – front view

Belkin IP 5232K — Connector table diagram (page 9)
Fig. 2 · Connector table
ConnectorFunction Local ConsoleConnect a keyboard, video, and mouse to operate the Switch locally. Serial 1Connect any serial device. Serial 2Connect any serial device. Connect to 10/100Mb Ethernet. Yellow LED LANilluminates when connected to a LAN. Green LED illuminates when a remote session is in progress. Server PortsConnect to servers via SIMs (Server Interface Modules). VM1Connect to server on server port 1 via USB cable. VM2Connect to server on server port 2 via USB cable.
Belkin IP 5232K — Connector table diagram (page 9)
Fig. 3 · Connector table
LEDFunction PortSolid: Server is connected to and powered on Fast Blink: When a port is being accessed remotely Slow Blink: When a port is being accessed locally Solid Green: When unit is available for use Ready LinkBlinking Green: Unit is connected to the network Power Power Indicator
Page 10 of the Belkin IP 5232K user manual — Avoiding general rack-mounting problems
Page 10 · click to enlarge
Page 10

INSTALLATION

Pre-Installation Guidelines

Mechanical loading Mount the equipment in the rack in such a way that a hazardous condition is not achieved due to uneven mechanical loading.

  • Place cables away from fluorescent lights, air conditioners, and machines that are likely to generate electrical noise.

Circuit overloading When connecting the equipment to the supply circuit, consider the effect that overloading of circuits might have on over-current protection and supply wiring.

  • Place the Switch on a flat, clean, and dry surface.
  • The Switch is not intended for connection to exposed outdoor lines.
  • Ensure that the maximum distance between each computer and the Switch does not exceed 100 ft. for SIMs.

Reliable electrical grounding of rack-mounted equipment should be maintained. Provide attention to supply connections other than direct connections to the branch circuit (e.g., use of power strips).

Avoiding general rack-mounting problems

Elevated operating ambient temperature The operating ambient temperature of the rack environment may be greater than the room ambient when installing into a closed or multiunit rack assembly. Install the equipment in an environment compatible with the maximum rated ambient temperature.

Reduced airflow Install the equipment in a rack in such a way that the amount of airflow required for safe operation is not compromised. Leave a gap of at least 5cm/2 inches on each side of the Switch.

Page 11 of the Belkin IP 5232K user manual — INSTALLATION
Page 11 · click to enlarge
Page 11

INSTALLATION

Rack-mounting the SMB IP KVM Switch

Place the brackets toward the front of the unit so that the unit can be mounted front facing; or place the brackets toward the rear of the unit so that it can be mounted rear facing on the back of a rack. Figure 4 illustrates the bracket connected for rear facing. Screw the bracket to the Switch using the screws provided.

Rack-mount the Switch using the supplied rack-mount kit. The brackets can be placed in two possible positions (see Figure 3).

Belkin IP 5232K — INSTALLATION diagram (page 11)
Fig. 4
Belkin IP 5232K — INSTALLATION diagram (page 11)
Fig. 5

Figure 3 Bracket positions

Figure 4 Bracket connected

Page 12 of the Belkin IP 5232K user manual — INSTALLATION
Page 12 · click to enlarge
Page 12

INSTALLATION

Connecting the System

Belkin IP 5232K — INSTALLATION diagram (page 12)
Fig. 6

Figure 5 Switch’s system overview

Page 13 of the Belkin IP 5232K user manual — INSTALLATION
Page 13 · click to enlarge
Page 13

INSTALLATION

The Server Interface Modules (SIMs)

Each computer/server is directly connected to the Switch via the appropriate SIM using CAT5 cables in a star configuration. No external power is needed at the remote SIMs. The SIMs draw their power from the computer’s keyboard port (PS/2 SIM) or from the USB port (USB SIM). The figures below illustrate the SIM PS/2 and USB.

Belkin IP 5232K — INSTALLATION diagram (page 13)
Fig. 7
Belkin IP 5232K — INSTALLATION diagram (page 13)
Fig. 8

Figure 6 USB SIM2 (part no. F1DP101A-AU)

Figure 7 PS/2 SIM (part no. F1DP101A-AP)

Page 14 of the Belkin IP 5232K user manual — The Server Interface Modules (SIMs)
Page 14 · click to enlarge
Page 14
Page 14 of the Belkin IP 5232K user manual — The Server Interface Modules (SIMs)
Page 15 of the Belkin IP 5232K user manual — The Server Interface Modules (SIMs)
Page 15 · click to enlarge
Page 15
Page 15 of the Belkin IP 5232K user manual — The Server Interface Modules (SIMs)
Page 16 of the Belkin IP 5232K user manual — INSTALLATION
Page 16 · click to enlarge
Page 16

INSTALLATION

Setting the IP Address

2. Press “F2”. The Settings window appears (see Figure 11).

By default, the Switch boots with an automatically assigned IP address from a DHCP (Dynamic Host Configuration Protocol) server on the network. The DHCP server provides a valid IP address, gateway address, and subnet mask.

Belkin IP 5232K — INSTALLATION diagram (page 16)
Fig. 9

You can identify the IP address from the OSD at the local position. You can set the IP address locally via the OSD where there is no DHCP server as follows:

1. From the local keyboard, press “Scroll Lock”. The OSD Main window appears (see Figure 10).
Belkin IP 5232K — INSTALLATION diagram (page 16)
Fig. 10

Figure 11 Settings window

In the Settings window, navigate downward using the Tab key. At the bottom of the window, press “Tab” to go to the top of the window. Change settings by typing in the selected area or by pressing the space bar—whichever is relevant.

Figure 10 OSD Main window

Page 17 of the Belkin IP 5232K user manual — INSTALLATION
Page 17 · click to enlarge
Page 17

INSTALLATION

Changing the network parameters Enable DHCP – When a DHCP server is active on the same network to which the Switch is connected, DHCP provides automatic IP assignment.

When DHCP is disabled (Recommended) – You can assign a fixed IP address to the Switch.

Consult your network administrator regarding the use of the DHCP. When DHCP is disabled, enter the IP Address, Subnet Mask, and Gateway as given by your network administrator.

Once the IP address is satisfactory, log in to the web interface to complete the configuration, as explained in the next section. (Network parameters can also be changed from the remote GUI as explained on page 17).

Page 18 of the Belkin IP 5232K user manual — WEB INTERFACE
Page 18 · click to enlarge
Page 18

WEB INTERFACE

Logging In to the Web Interface

SSL certificate notes

Client computer operating system. Windows 2000 or higher, with Internet Explorer 6.0 or later version. 128-bit encryption support is required.

When first connecting, two browser security warnings appear. Click “Yes” to proceed.

The first warning disappears upon the first Switch client installation, when Belkin’s root certificate is installed.

Windows Vista Note! To log in to the web configuration interface with Windows Vista, run Internet Explorer as “administrator.” To do this, right-click the Internet Explorer icon on the task bar and select “Run” as “administrator.” See figure below.

On first connection, install the Belkin certificate and ActiveX control. You must be logged in as an administrator on your computer to install the ActiveX control. Once the ActiveX control is installed, all types of users can log in.

Belkin IP 5232K — WEB INTERFACE diagram (page 18)
Fig. 11

Figure 12 Select Run as administrator

Page 19 of the Belkin IP 5232K user manual — WEB INTERFACE
Page 19 · click to enlarge
Page 19

WEB INTERFACE

Logging in

Belkin IP 5232K — WEB INTERFACE diagram (page 19)
Fig. 12

To complete the initial setup via the web configuration interface:

1. Open your web browser (Internet Explorer version 6.0 or higher).
2. Type the Switch’s system IP address—http or https://IP address/ - and press “Enter”. The login page appears (see Figure 13).
Belkin IP 5232K — WEB INTERFACE diagram (page 19)
Fig. 13

Figure 14 Targets page

By default, an administrator can access all connected Targets, so they all appear on the Targets page.

Figure 13 Login page

Columns:

3. Type the default administrator user name ( admin ) and password ( SMBremote ) (case-sensitive).

Server Name – The server name can be changed in the configuration settings to give the server an identifiable name.

4. Press “Enter”. The web interface opens at the Targets page (see Figure 14).

Port Status – Port status can be on, off, or busy (i.e., another user is accessing the server).

5. Bookmark the page for easy reference.

Current User – The current user (if any) who is accessing the target.

Page 20 of the Belkin IP 5232K user manual — Configuring the System
Page 20 · click to enlarge
Page 20

WEB INTERFACE

Connecting to a target server

Network > Configuration

To connect to a target, click the desired target in the Server Name column. The screen of the target appears inside the remote console window. The “Accessing a Target Server” section on page 28 explains how to conduct a remote session. The following sections first explain how to configure the system.

Consult your network administrator for the network settings if necessary.

Device Name – Type a name for the Switch.

TCP Ports – Choose any three TCP ports between ports 800 to 65535. When the Switch is a standalone system, the ports do not have to be consecutive. (The port numbers can be changed from Central Access Appliance, if needed.)

Configuring the System

Configuring the system includes setting network parameters, user and security settings, and maintenance.

From the menu, click “Configuration”. The “Network > Configuration” page, including the Configuration menu, appears:

Belkin IP 5232K — Configuring the System diagram (page 20)
Fig. 14 · Configuring the System

For client computer access from a secured LAN, the selected ports should be open for outbound communication.

Figure 15 Network > Configuration page

Page 21 of the Belkin IP 5232K user manual — WEB INTERFACE
Page 21 · click to enlarge
Page 21

WEB INTERFACE

LAN

OmniView IP Central Access Appliance 5000HQ

Under LAN in Figure 14, is the following:

OmniView IP 5000HQ is a centralized, IP-based system for secure control of servers and network devices, power, and user administration in the datacenter environment. The 5000HQ combines out-of-band, KVM-via-IP access with modern IT standards and requirements. It is the most comprehensive remote server maintenance solution available in the market today.

Enable DHCP – When a DHCP server is active on the same network to which the Switch is connected, DHCP provides automatic IP assignment.

When DHCP is disabled (Recommended) – You can assign a fixed IP address to Switch.

Enable OmniView IP 5000HQ – Check this option to allow the Switch to be remotely managed by Central Manager Appliance 5000HQ.

Consult your network administrator regarding the use of the DHCP.

When DHCP is disabled, enter the IP Address, Subnet Mask, and Default Gateway for LAN, as given by your network administrator. These parameters can be configured locally from the OSD as explained on page 14.

Manager Auto Discovery – When checked, 5000HQ automatically detects the Switch if it resides on the same network segment.

Manager IP – If the Switch resides on a different segment, type the static IP address of the 5000HQ management appliance. (We advise typing the static IP address of the 5000HQ management appliance even if the Switch resides on the same network segment as the 5000HQ management appliance.)

Page 22 of the Belkin IP 5232K user manual — WEB INTERFACE
Page 22 · click to enlarge
Page 22

WEB INTERFACE

Administration > User Settings

Administrator An administrator has unrestricted access to all windows and settings and can “take over” any active session. An administrator can change the name and password and target server permissions of all users.

From the menu, click “User Settings” and Figure 16 appears.

Belkin IP 5232K — WEB INTERFACE diagram (page 22)
Fig. 15

User A user can access/control permitted target servers, but cannot use the advanced mouse settings.

A user has no access to the web-configuration interface.

View only “View only” can view the screen of the currently accessed target server without keyboard and mouse control. A “view only” indicator appears on the viewer’s local mouse pointer.

Figure 16 User Settings

On this page, an administrator creates and edits users.

There are three levels of user access:

  • Administrator
  • User
  • View only
Page 23 of the Belkin IP 5232K user manual — Administration > User Settings
Page 23 · click to enlarge
Page 23
Page 23 of the Belkin IP 5232K user manual — Administration > User Settings
Page 24 of the Belkin IP 5232K user manual — Administration > Serial Settings
Page 24 · click to enlarge
Page 24

WEB INTERFACE

Administration > Server Name Edit

2. In the “Server Name” section, change the name of the connected servers by selecting the server name and typing a new name. Click to save changes.

Give the servers connected to the Switch unique names, so that users accessing the system can identify the servers easily.

To do so:

Administration > Serial Settings

1. From the menu, click “Server Name Edit”. The Switch Configuration window appears (see Figure 17).

Where you have a serial device connected to the system, you must configure the serial (RS232) settings.

Belkin IP 5232K — Administration > Serial Settings diagram (page 24)
Fig. 16 · Administration > Serial Settings

To do so:

From the menu, click “Serial Settings”. The Serial Settings page will appear (see Figure 18).

Belkin IP 5232K — Administration > Serial Settings diagram (page 24)
Fig. 17 · Administration > Serial Settings

Figure 18 Serial Settings

For each serial device connected, type a device name and choose the correct device parameters.

Figure 17 Switch Configuration

Page 25 of the Belkin IP 5232K user manual — WEB INTERFACE
Page 25 · click to enlarge
Page 25

WEB INTERFACE

Administration > Server Access List

2. Select a user from the user drop-down menu.
3. Check the target servers the user can access (according to his or her access permissions). To select all target servers, click .

By default, access is allowed to all servers for administrators. For other users, define the access rights of each user separately.

To do so:

4. Click to save the selection.
1. From the menu, click “Server Access List”. The Access List Configuration window will appear (see Figure 19).
5. Repeat the steps above for additional users.
Belkin IP 5232K — WEB INTERFACE diagram (page 25)
Fig. 18

Figure 19 Server Access List Configuration

Page 26 of the Belkin IP 5232K user manual — WEB INTERFACE
Page 26 · click to enlarge
Page 26

WEB INTERFACE

Security > Settings

For local and remote users, you have the option of a standard or high security level of password. The table below shows the parameters of the two options.

Configure the security features, such as Account Blocking, Password Policy, and Idle Timeout, as explained below.

From the Security section, click “Settings”. The “Security > Settings” page appears (see Figure 20).

Standard security policy High security policy

8 characters or more, must include at least 1 digit and 1 uppercase letter, and 1 “special” character as follows: !@#$%^*()_-+=[]’:;?/

Belkin IP 5232K — WEB INTERFACE diagram (page 26)
Fig. 19

6 characters or more

Must not include the user name Must not include the user name

Check the box to enable the high security password policy. If left unchecked, the standard security policy applies.

OSD password enabled – For the local user, access to the OSD can be password enabled or disabled (default), with the option of a standard or high security level of password as explained above. Select the check box to enable password.

Figure 20 Security Settings

Security Settings fields:

Idle Timeout – Select the timeout inactivity period after which the user is disconnected from the system. Choose “No Timeout” to disable timeout.

Account Blocking – Decide on the number of attempts to log in with a wrong user name or password, after which there is a time lock or a total block.

Click to save any security changes.

Password Policy

Page 27 of the Belkin IP 5232K user manual — WEB INTERFACE
Page 27 · click to enlarge
Page 27

WEB INTERFACE

Security > SSL Certificate

Maintenance > Switch Upgrade

You can install an SSL certificate.

Upgrade the Switch firmware to take advantage of new features. Download the firmware from the support section of Belkin’s website at www.belkin.com/support Save the firmware file on the client computer.

To do so:

From the menu, select “SSL Certificate”. The Install SSL Certificate page appears (see Figure 21).

From the menu, select “Switch Upgrade”. The Upgrade window will appear, showing the current firmware version (see Figure 22).

Belkin IP 5232K — WEB INTERFACE diagram (page 27)
Fig. 20
Belkin IP 5232K — WEB INTERFACE diagram (page 27)
Fig. 21

Figure 22 Firmware Upgrade

1. Locate and upload the firmware file.

Figure 21 Install SSL Certificate page

2. Verify the current and uploaded version of the firmware.
3. Click to begin the upgrade process. The unit will reboot automatically. You should see the Login page reappear after about two minutes.

Certificate File – Browse to locate the “cer” file (.ssl format).

Private Key File – Browse to locate the “private key” file (.pem format).

Key Password – Type the key password.

Click . The certificate installs. The device restarts automatically.

Depending on the type of firmware upgrade type, the following settings may be erased: user settings, server names, and mouse and video adjustments. For more information, refer to the firmware release notes.

The network settings will remain intact.

Page 28 of the Belkin IP 5232K user manual — Security > SSL Certificate
Page 28 · click to enlarge
Page 28
Page 28 of the Belkin IP 5232K user manual — Security > SSL Certificate
Page 29 of the Belkin IP 5232K user manual — WEB INTERFACE
Page 29 · click to enlarge
Page 29

WEB INTERFACE

Set Time and Date

Back Up and Restore

The time and date set feature is used when recording log events. To set the time and date:

You can back up all configuration data to restore it at a later date. To do so:

From the menu, select “Time & Date” and Figure 25 appears.

From the menu, select “Backup & Restore” and Figure 26 appears.

Belkin IP 5232K — WEB INTERFACE diagram (page 29)
Fig. 22
Belkin IP 5232K — WEB INTERFACE diagram (page 29)
Fig. 23

Figure 26 Backup & Restore

Figure 25 Set Time & Date

To back up the configuration data, click to save the file.

To restore the configuration data, browse to locate the file and press . The device restarts.

Type the appropriate parameters.

Page 30 of the Belkin IP 5232K user manual — WEB INTERFACE
Page 30 · click to enlarge
Page 30

WEB INTERFACE

Saving Changes and Logging Out

To save any configuration changes, click the relevant button on the current page. This could be or just .

To restart the Switch, press .

To exit the Configuration menu and close the session, click .

Only one administrator can log in to the Configuration area at a time. After the idle timeout (see the “Security > Settings” section on page 23), the session terminates.

Page 31 of the Belkin IP 5232K user manual — Accessing a Target Server
Page 31 · click to enlarge
Page 31

Accessing a Target Server

On the remote console you have the following:

Server name – The currently accessed server identity can be checked any time by looking at the “Server name” on the Internet Explorer title bar.

Log in to the web interface, as explained on page 16. The web interface opens at the Targets page (see Figure 14 on page 16). To connect to a target or serial device, click the desired target/device in the Server Name column. (A server being used by another user cannot be accessed.) The screen of the target/device appears inside a remote console window.

Toolbar icon – This is the minimized toolbar from which you switch and configure the system.

Remote Session icon – Hold the mouse over the icon to view information about current server, connection time, and video mode.

NOTE: If a user connects to a target device with a higher screen resolution than the local computer, the remote viewer window will display a portion of the target device screen, with scroll bars for viewing the remainder of the screen. The user may view the entire screen by adjusting the resolution on the target device, the local computer, or both.

Belkin IP 5232K — Accessing a Target Server diagram (page 31)
Fig. 24 · Accessing a Target Server

Figure 27 Remote Console window

Page 32 of the Belkin IP 5232K user manual — Switching to a different server
Page 32 · click to enlarge
Page 32

The Toolbar

Changing the performance settings

To maximize the toolbar:

You can alter the bandwidth settings from the toolbar.

Click the arrow . Click again to minimize the toolbar.

To alter the settings:

When maximized, the toolbar can be dragged and dropped to anywhere on the screen, by dragging the icon . When minimized, the icon glides to a side of the screen.

From the toolbar, click . The “Settings...” dialog box appears (see Figure 28).

To hide the toolbar, either:

Belkin IP 5232K — The Toolbar diagram (page 32)
Fig. 25 · The Toolbar

Double-click the Switch system tray icon .

Press “F9”.

To display the toolbar, repeat the action above. Also see page XX.

Switching to a different server

To connect to a different server:

1. From the toolbar, click or right-click . A list of available servers appears. The currently connected server is highlighted in bold.
2. Click the desired server name. The screen of the selected server appears.

Figure 28 Settings.. Dialog box

or

Page 33 of the Belkin IP 5232K user manual — Refresh
Page 33 · click to enlarge
Page 33

Bandwidth

Adjusting the video settings

Choose from the following options:

To change the video settings:

Adaptive – Automatically adapts to the best compression and colors according to the network conditions. (Not recommended because network parameters may change frequently, impacting on user experience.)

From the toolbar, click . You have the following options:

  • Refresh
  • Manual Video Adjust

Low – Select “Low” for high compression and 16 colors.

  • Auto Video Adjust

Medium – Select “Medium” for medium compression and 256 colors. Medium is recommended when using a standard Internet connection.

Each option is explained below.

High – For optimal performance when working on a LAN, select “High”. This gives a low compression and high colors (16-bit).

Refresh

Custom – You can choose your own compression and color levels.

Click “OK”. The screen of the last accessed target server appears.

Select “Refresh” to refresh the video image. Refresh may be needed when changing the display attributes of a target server.

Page 34 of the Belkin IP 5232K user manual — Manual video adjust
Page 34 · click to enlarge
Page 34

Manual video adjust

Belkin IP 5232K — Manual video adjust diagram (page 34)
Fig. 26 · Manual video adjust

Use the manual video adjustment for fine-tuning the target server video settings after auto adjustment. This feature should also be used for adapting to a noisy environment, a non-standard VGA signal, or when in full-screen DOS/CLI mode.

To adjust the video manually:

Click “Manual Video Adjust”. The manual controls appear (see Figure 29). A red frame also appears around the screen. This represents the screen area according to the server’s screen resolution. Perform the adjustments inside and relative to this frame.

Brightness/Contrast – Use the scales to adjust the brightness and contrast of the displayed image. Move the sliders to change the displayed image. Click in the area of the sliders for fine-tuning.

For the following controls, choose the appropriate measurement.

Horizontal Offset – Defines the starting position of each line on the displayed image.

Vertical Offset – Defines the vertical starting position of the displayed image.

Phase – Defines the point at which each pixel is sampled.

Scale – Defines the scale resolution of the session image.

Select Filter – Defines the filter of the input video from the server. A higher filter reduces the noise level, but makes the image heavier.

Noise Level – Represents the video “noise” when a static screen is displayed.

Figure 29 Manual Video

Adjustments controls

Page 35 of the Belkin IP 5232K user manual — Keyboard key sequences
Page 35 · click to enlarge
Page 35

Auto video adjust

Belkin IP 5232K — Auto video adjust diagram (page 35)
Fig. 27 · Auto video adjust

To adjust the video automatically:

Click “Auto Video Adjust”. The process takes a few seconds. If the process runs for more than three times, there is an abnormal noise level. Check the video cable and verify that no dynamic video application is running on the target server’s desktop.

Perform the procedure where necessary for each target server or new screen resolution.

Keyboard key sequences

Click . A list of defined keyboard sequences appears. When clicked, these transmit directly to the target server, and will not affect the client computer.

Figure 30 Special Key Manager box

For example, select “Ctrl-Alt-Del” to send this 3-key sequence to the target server to initiate its shutdown/login process.

To add a predefined sequence:

1. Click “Add Predefined”. A list of sequences appears.

To add a keyboard sequence:

2. Select the desired sequence and click “OK”. The sequence appears in the Special Key Manager box.

Click “Add/Remove”. The Special Key Manager box appears (see Figure 30).

3. Click “OK”. The sequence appears in the Keyboard Key sequence list.
Page 36 of the Belkin IP 5232K user manual — Auto video adjust
Page 36 · click to enlarge
Page 36
Page 36 of the Belkin IP 5232K user manual — Auto video adjust
Page 37 of the Belkin IP 5232K user manual — Auto video adjust
Page 37 · click to enlarge
Page 37
Page 37 of the Belkin IP 5232K user manual — Auto video adjust
Page 38 of the Belkin IP 5232K user manual — Red Hat ® , Fedora, and other Linux distributions
Page 38 · click to enlarge
Page 38

Red Hat ® , Fedora, and other Linux distributions

When accessing the target server, the mice may appear at a distance to each other.

1. Go to “Mouse Preferences”.

To align the mouse pointers:

2. Then navigate to the “Motion” tab.

From the toolbar, click “ / Align” or press (left) “Ctrl+M” simultaneously. The mice will align.

Belkin IP 5232K — Red Hat ® , Fedora, and other Linux distributions diagram (page 38)
Fig. 28 · Red Hat ® , Fedora, and other Linux distributions
3. Set the “Acceleration” to five clicks from left.
4. Set the “Sensitivity” to three clicks from left.
5. Set the “Threshold” to two clicks from left.
Page 39 of the Belkin IP 5232K user manual — Manual settings
Page 39 · click to enlarge
Page 39

Manual settings

2. Select the target server’s operating system and click “OK”. Instructions and sliders appear. Note: You must do this configuration on every port.

If the mouse settings on the target server were ever changed, or when the operating system on the target server is Windows XP, 2003 Server, Vista, or 2008 Server, or Linux, Novell, SCO UNIX®, or Sun Solaris, you must configure the mouse manually.

3. Follow the instructions and set any relevant sliders to the same values as set in the target server’s “Mouse Properties” window.

To manually configure the mouse:

4. Check USB if the SIM you are using is USB type.

Click “OK”. The mouse pointers should be synchronized. There will be no need to perform this setup unless you change the server attached to the particular port.

1. From the toolbar, click “ / Manual Settings”. The “Mouse Settings” dialog box appears (see Figure 32).
Belkin IP 5232K — Manual settings diagram (page 39)
Fig. 29 · Manual settings

Figure 32 Mouse Settings Dialog box

Page 40 of the Belkin IP 5232K user manual — Advanced – Mouse emulation
Page 40 · click to enlarge
Page 40

Advanced – Mouse emulation

Belkin IP 5232K — Advanced – Mouse emulation diagram (page 40)
Fig. 30 · Advanced – Mouse emulation

Click and the “Mouse Emulation” dialog box appears (see Figure 33).

Belkin IP 5232K — Advanced – Mouse emulation diagram (page 40)
Fig. 31 · Advanced – Mouse emulation

Figure 34 Mouse Emulation dialog box for use with touch pads

Press “OK” to save settings.

This “Mouse Emulation” setting is used to determine the correct reset sequence for a local mouse. Setting it incorrectly may lead to a jumpy or non-operational local console mouse after a remote user disconnects it from the Switch.

Figure 33 Mouse Emulation dialog box

Max Rate - This defines the maximum mouse report rate. For Sun Solaris, the default value is 20 in order to support older Sun versions.

If a 2-button mouse (older mice without wheel capability, most of the touch pads, trackballs, or integrated keyboards with mice used in most of the rack drawers) is connected to the local KVM port of the Switch, set the “Mouse Emulation” to “Standard Mouse” (see Figure 34).

Page 41 of the Belkin IP 5232K user manual — Calibrating mice pointers
Page 41 · click to enlarge
Page 41

Calibrating mice pointers

Adjustments in general

A target server may have a different mouse pointer speed to the client computer. Calibrating automatically discovers the mouse speed of the target server and aligns the two pointers.

The above adjustments, namely:

  • Performance settings

To perform the calibration when the target server’s operating system is Windows NT® 4, 2000, or 98:

  • Video settings
  • Keyboard key sequences

From the toolbar, click “ / Calibrate”. The Switch saves this alignment so calibration is only needed once per target server.

  • Synchronizing mouse pointers

If the video noise level is above zero, calibration may not work. Go to “Video Adjustment” and try to eliminate the noise by pressing “Auto video adjust” and/or adjusting the bars in manual video adjust. Then perform the mouse calibration.

may have to be performed twice for each target.

Page 42 of the Belkin IP 5232K user manual — Globe icon menu features
Page 42 · click to enlarge
Page 42

Globe icon menu features

Hide Toolbar – Check this option to hide the toolbar from the next reconnection onward. To toggle the toolbar on and off, press “F9” or double-click the system tray icon .

Right-click the globe icon and a menu appears. From this menu you can access the connected devices. You also have the following features:

Full-Screen Mode – Check this option to make the remote session screen appear in full-screen mode from the next reconnection onward. To toggle the full-screen mode on and off, press “F11” (also see the next section).

Disconnect – You can disconnect the session by clicking “Disconnect”.

About – Click “About to verify the Client, Firmware and Switch” file versions installed on your Switch.

Virtual Media – Click this option to mount virtually any removable mass storage devices connected to the client computer onto the target server.

Local Settings – Click “Local settings” and the “Client Configuration” dialog box appears (see Figure 35).

Belkin IP 5232K — Globe icon menu features diagram (page 42)
Fig. 32 · Globe icon menu features

Figure 35 Client Configuration dialog box

Pointer Type – From the drop-down menu, you can change the client computer mouse pointer to appear as a dot or to not appear at all.

Page 43 of the Belkin IP 5232K user manual — Virtual media
Page 43 · click to enlarge
Page 43

Virtual media

1. Click “Virtual Media” and the “Virtual Media” dialog box appears (see Figure 36). All connected mass storage devices appear in the “Local Drives” section.

With virtual media, you can virtually mount removable mass storage devices connected to the client computer onto the target server.

This includes:

Belkin IP 5232K — Virtual media diagram (page 43)
Fig. 33 · Virtual media
  • Floppy drives
  • CD-ROMs
  • DVD-ROMs
  • ISO images of CD\DVD
  • USB flash drives (disk on key tokens)
  • Miscellaneous USB memory sticks/cards identified by the operating system as removable mass storage devices

Setup Virtual media is only supported by server ports 1 and 2. You must connect a separate USB cable to VM ports 1 and 2 located on the back of the Switch and match to the corresponding servers connected to server ports 1 and 2. 2. Select the device to be mounted and click “Mount”. A remote device warning should appear.

Figure 36 Virtual Media

3. Click “OK”. The device mounts onto the target server and appears as a removable or CD/DVD drive of the target server. It also appears in the “Mounted Drives” section in Figure 36. Once mounted, you can use the device during the remote session as if it is connected to the target server.

Mounting a Drive

Page 44 of the Belkin IP 5232K user manual — Virtual media
Page 44 · click to enlarge
Page 44

Mounting an ISO file

  • Only drives identified by the client’s operating system as drives with removable storage can be mounted as virtual media. Many USB-attached hard disks identify themselves to the operating system as hard-disk drives and can’t be used for virtual-media mounting.

An ISO image (.iso) is a disk image of an ISO 9660 file system, and refers to any optical disc image, even a UDF image. In addition to the data files in the ISO image, it also contains all the file system metadata, including boot code, structures, and attributes. All of this information is contained in a single file. These properties make it an attractive alternative to physical media for the distribution of software that requires this additional information as it is simple to retrieve over the Internet.

  • Booting from a mounted virtual-media drive is possible only if the target server supports booting from USB-attached storage.
  • Currently, it is not possible to boot a target server from Linux distribution mounted as virtual media.

To mount an ISO file, click “Mount ISO File”, locate the file, and mount it.

Things to know about operation of the virtual media

  • Windows CD/DVD, or its modifications such as Winternals ERD Commander, WinPE, BartPE, or similar, can be used for booting the target server when mounted as virtual media.

Because virtual media emulates USB 1.1 over a TCP connection, it has a number of limitations that govern the virtual-media compatibility and operation.

  • Mounting removable mass storage devices such as USB flash drives (disk on key tokens) or miscellaneous USB memory sticks/ cards will remove them from the client’s operating system and redirect them with read/write access permissions to the target server to ensure the integrity of write operation.
  • Virtual media emulates USB 1.1. It doesn’t emulate USB 2.0.
  • Virtual media redirects the client’s local DVD/CD or removable mass storage devices to a target server during the open client session only. This means if the remote client session disconnects, the mounted drives will be automatically dismounted from the target server.
  • Connection timeout will not occur at the time the virtual media remains mounted.
  • Maximum data transfer speed of the virtual media doesn’t exceed 5.0Mbps.
Page 45 of the Belkin IP 5232K user manual — The Targets Page Menu
Page 45 · click to enlarge
Page 45

Full-screen mode

Disconnecting the remote session

Work on the target server as if you are working on a local computer with full-screen mode.

To disconnect the session, click on the toolbar. The Login page appears. You can re-log in, or close the browser window to disconnect the session.

To work in full-screen mode:

1. Ensure that the client’s computer has the same screen resolution as the target server.

The Targets Page Menu

2. Press “F11”. The Internet Explorer window disappears, leaving the Internet Explorer menu bar at the top.

When logging in to the system as an administrator or a user, you reach the Targets page (see Figure 14 on page 16). From the menu, you can:

3. Right-click the Internet Explorer menu bar and check “Auto-Hide”. The Internet Explorer menu bar disappears. You are in full-screen mode.
  • Change the password
  • See an event log

To exit full-screen mode:

Press “F11”, or place the mouse at the top of the window to display the Internet Explorer toolbar and click the “Restore” button.

Page 46 of the Belkin IP 5232K user manual — Clearing the log
Page 46 · click to enlarge
Page 46

Changing the password

Belkin IP 5232K — Changing the password diagram (page 46)
Fig. 34 · Changing the password

To change the password, click “Password” from the menu and the following appears.

Belkin IP 5232K — Changing the password diagram (page 46)
Fig. 35 · Changing the password

Figure 37 Events log

Navigate through the event pages using the forward or backward arrows, marked as (A) in Figure 37.

From the drop-down menu, marked as (B) in Figure 37, choose the number of events that will appear on each page (10–40).

Type a new password according to the password policy set (see page 19).

Downloading the log

Event log

You can download and save the log.

To see a log of all system events:

To do so, click and save as a “.csv” file. The file can be viewed using Microsoft Excel® or compatible software.

From the menu, select “Event Log” and the following screen appears.

Clearing the log

To clear the log, click . A prompt appears asking if you first want to save the log.

Figure 36 Password

Page 47 of the Belkin IP 5232K user manual — Selecting a computer
Page 47 · click to enlarge
Page 47

LOCAL ACCESS

Navigating the OSD Main window

This section explains how to operate the Switch locally via the OSD.

The OSD

To navigate up and down, use the up and down arrow keys.

To exit the OSD, press “Esc”.

To display the OSD:

1. From the local keyboard, press the left “Scroll Lock” key twice. The OSD Main window appears (see Figure 38). The “Pwr” column indicates the server is powered on.

Selecting a computer

To select a computer:.

1. Navigate to the desired computer line.

Or, type the 2-digit port number of the desired computer.

2. Press “Enter”. The selected computer is accessed. A confirmation label appears showing which computer is accessed.

Figure 38 OSD Main window

Page 48 of the Belkin IP 5232K user manual — LOCAL ACCESS
Page 48 · click to enlarge
Page 48
Page 48 of the Belkin IP 5232K user manual — LOCAL ACCESS
Page 49 of the Belkin IP 5232K user manual — LOCAL ACCESS
Page 49 · click to enlarge
Page 49

LOCAL ACCESS

The Settings window – F2

5000HQ MNG – Press the space bar to toggle between enabling and disabling management by the 5000HQ. When enabled, the Switch is remotely managed by OmniView IP Central Management Appliance 5000HQ.

Press “F2”. The Settings window appears (see Figure 40).

5000HQ ADD – Here you can change the static IP address of the 5000HQ.

HOT KEY – Pressing “Scroll Lock” twice in quick succession will make the OSD appear. You can replace “Scroll Lock” with any of the other hot-key options following:

  • Ctrl, Ctrl (left Ctrl key only)
  • Ctrl, F11 (left Ctrl key only)
  • Print Screen

Figure 40 Settings window

Press the space bar to toggle between options. To display the OSD in the future, press the new hot key.

In the Settings window, navigate downward using the “Tab” key. At the bottom of the window, press “Tab” to go to the top of the window. Change settings by typing in the selected area or by pressing the space bar, whichever is relevant.

KEYBOARD LANGUAGE – Press the space bar to toggle between the language options. It can be changed to French or German.

From this window, you can do the following:

Changing the network parameters from the OSD is explained with the initial configuration in the “Setting the IP Address” section on page 13.

Page 50 of the Belkin IP 5232K user manual — Updating the DDC information
Page 50 · click to enlarge
Page 50

LOCAL ACCESS

DDC – F10

Saving changes to the settings

Display Data Channel (DDC) is a VESA standard for communication between a monitor and a video adapter.

To save changes to the settings and return to the Main window, press “Esc”.

From the Settings window, input the DDC information of the monitor connected to the Switch into the memories of all connected SIMs when first installing the system.

To input the DDC information:

Press “F10”. “Please wait” flashes a few times and disappears. The monitor’s DDC information is sent to all SIMs.

Updating the DDC information

Update the DDC information in any of the following circumstances:

  • When replacing the monitor connected to the Switch
  • When adding a new SIM to the system
  • When reconnecting an existing SIM that was temporarily used in a different system

To update the DDC information, repeat the steps as set out above.

Page 51 of the Belkin IP 5232K user manual — VGA - HDD15
Page 51 · click to enlarge
Page 51

Additional information

Technical Specifications

Dimensions (H x D x W) 44 x 270 x 431mm/1.7 x 10.6 x 17 in.

Windows, Novell, Linux, Sun Solaris

Power Input 100–240VAC, 0.8A, 50/60Hz

Windows 2000 or higher with IE 6.0 or higher and ActiveX

Operating Temperature 0° C to 40° C/32° F to 104° F

Storage Temperature -40° C to 70° C/-40° F to 158° F

Recommended - resolution should be higher than on the target server

Humidity 80% non-condensing relative humidity

Distance from Switch to SIMs Up to 30m/99 ft.

PS/2 SIM USB SIM

Video and Mouse Synchronization Both auto and manual modes

VGA - HDD15

VGA - HDD15

KM - USB

Security 128-bit SSL encryption, 256-bit AES encryption

Ethernet – RJ45 – 10/100bps auto-sensing

Power From keyboard port From USB port

Serial – RJ45 x 2

Local KVM Connection – Screen HDD15, Keyboard/ Mouse – 2 USB

Product Weight 100g/0.20 lbs.

Shipping Weight 172g/0.38 lbs.

Weight 2.343kg./5.165 lbs.

Dimensions 65 x 25 x 25mm/0.21 x 0.08 x 0.08 in.

Show 13 more labels / short text on this page
Target Server · Operating Systems · Client Computer · Target Server · Up to 1600x1200@85Hz · Resolution · Client Computer · Connections · KM - MiniDIN6 · System - RJ45 · System - RJ45 · Connections · Servers – RJ45
Page 52 of the Belkin IP 5232K user manual — Additional information
Page 52 · click to enlarge
Page 52

Additional information

Video Resolution and Refresh Rates

Belkin IP 5232K — Additional information diagram (page 52)
Fig. 36 · Additional information

Hz 56 60 65 66 70 72 73 75 76 85 86

Page 53 of the Belkin IP 5232K user manual — Product Registration
Page 53 · click to enlarge
Page 53

Additional information

Safety

This device contains no serviceable parts. Any servicing of the device must be performed by Belkin International, Inc.

User Manual Feedback

Your feedback is very important to help us improve our documentation. Please email any comments to: techsupp@belkin.com.

Please include the following information: Manual name, part number, and P number.

Product Registration

You may register your product online by going to https://www.belkin.com/registration/

This will assist Belkin in contacting you regarding important information regarding the use of your product.

Page 54 of the Belkin IP 5232K user manual — ICES
Page 54 · click to enlarge
Page 54

Additional information

Information

FCC Statement DECLARATION OF CONFORMITY WITH FCC RULES FOR ELECTROMAGNETIC COMPATIBILITY

We, Belkin International, Inc., of 501 West Walnut Street, Compton, CA 90220, declare under our sole responsibility that the products:

CE Declaration of Conformity

We, Belkin International, Inc., declare under our sole responsibility that the products F1DP216G, F1DP232G, to which this declaration relates, are in conformity with Emissions Standard EN55022 and with Immunity Standard EN55024, LVP EN61000-3-2, and EN61000-3-3.

F1DP216G, F1DP232G

to which this declaration relates:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense.

ICES

This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme á la norme NMB-003 du Canada.

Page 55 of the Belkin IP 5232K user manual — Additional information
Page 55 · click to enlarge
Page 55

Additional information

Belkin International, Inc. , Limited 2-Year Product Warranty

What this warranty covers.

and tear, erosion, depletion, obsolescence, abuse, damage due to low voltage disturbances (i.e., brownouts or sags), non-authorized program, or system-equipment modification or alteration.

Belkin International, Inc. (“Belkin”) warrants to the original purchaser of this Belkin product that the product shall be free of defects in design, assembly, material, or workmanship.

How to get service.

What the period of coverage is.

To get service for your Belkin product you must take the following steps:

Belkin warrants the Belkin product for two years.

1. Contact Belkin International, Inc., at 501 W. Walnut St., Compton CA 90220, Attn: Customer Service, or call (800)-223-5546, within 15 days of the Occurrence. Be prepared to provide the following information:

What will we do to correct problems?

Product Warranty.

Belkin will repair or replace, at its option, any defective product free of charge (except for shipping charges for the product). Belkin reserves the right to discontinue any of its products without notice, and disclaims any limited warranty to repair or replace any such discontinued products. In the event that Belkin is unable to repair or replace the product (for example, because it has been discontinued), Belkin will offer either a refund or a credit toward the purchase of another product from Belkin. com in an amount equal to the purchase price of the product as evidenced on the original purchase receipt as discounted by its natural use.

a. The part number of the Belkin product.

b. Where you purchased the product.

c. When you purchased the product.

d. Copy of original receipt.

2. Your Belkin Customer Service Representative will then instruct you on how to forward your receipt and Belkin product and how to proceed with your claim.

What is not covered by this warranty?

All above warranties are null and void if the Belkin product is not provided to Belkin for inspection upon Belkin’s request at the sole expense of the purchaser, or if Belkin determines that the Belkin product has been improperly installed, altered in any way, or tampered with. The Belkin Product Warranty does not protect against acts of God such as flood, lightning, earthquake, war, vandalism, theft, normal-use wear

Page 56 of the Belkin IP 5232K user manual — Additional information
Page 56 · click to enlarge
Page 56

Additional information

Belkin reserves the right to review the damaged Belkin product. All costs of shipping the Belkin product to Belkin for inspection shall be borne solely by the purchaser. If Belkin determines, in its sole discretion, that it is impractical to ship the damaged equipment to Belkin, Belkin may designate, in its sole discretion, an equipment repair facility to inspect and estimate the cost to repair such equipment. The cost, if any, of shipping the equipment to and from such repair facility and of such estimate shall be borne solely by the purchaser. Damaged equipment must remain available for inspection until the claim is finalized. Whenever claims are settled, Belkin reserves the right to be subrogated under any existing insurance policies the purchaser may have.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

IN NO EVENT SHALL BELKIN BE LIABLE FOR INCIDENTAL, SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR MULTIPLE DAMAGES SUCH AS, BUT NOT LIMITED TO, LOST BUSINESS OR PROFITS ARISING OUT OF THE SALE OR USE OF ANY BELKIN PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

This warranty gives you specific legal rights, and you may also have other rights, which may vary from state to state. Some states do not allow the exclusion or limitation of incidental, consequential, or other damages, so the above limitations may not apply to you.

How state law relates to the warranty.

THIS WARRANTY CONTAINS THE SOLE WARRANTY OF BELKIN. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR, EXCEPT AS REQUIRED BY LAW, IMPLIED, INCLUDING THE IMPLIED WARRANTY OR CONDITION OF QUALITY, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND SUCH IMPLIED WARRANTIES, IF ANY, ARE LIMITED IN DURATION TO THE TERM OF THIS WARRANTY.

Page 57 of the Belkin IP 5232K user manual — Information
Page 57 · click to enlarge
Page 57

Belkin Tech Support US: 800-282-2355 310-898-1100, ext. 2263 UK: 0845 607 77 87 Australia: 1800 235 546 New Zealand: 0800 235 546 Singapore: 65 64857620 Europe: www.belkin.com/support

Belkin International, Inc. 501 West Walnut Street Los Angeles, CA 90220, USA 310-898-1100 310-898-1111 fax

Belkin B.V. Boeing Avenue 333 1119 PH Schiphol-Rijk The Netherlands +31 (0) 20 654 7300 +31 (0) 20 654 7349 fax

Belkin Ltd. Express Business Park, Shipton Way Rushden, NN10 6GL United Kingdom +44 (0) 1933 35 2000 +44 (0) 1933 31 2000 fax

Belkin Ltd. 4 Pioneer Avenue Tuggerah Business Park Tuggerah, NSW 2259, Australia +61 (0) 2 4350 4600 +61 (0) 2 4350 4700 fax

© 2009 Belkin International, Inc. All rights reserved. All trade names are registered trademarks of respective manufacturers listed. Windows, Windows Vista, Microsoft, NT, Internet Explorer, and ActiveX are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Belkin IP 5232K

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Belkin IP 5232K

Be the first to ask — other owners or our team will answer.

Original document

Belkin IP 5232K manual PDF

57 pages·5.1 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…