5216K/5232K User Manual
PM00020 - F1DP2XXG *OmniView is a registered trademark of Belkin International, Inc.





Congratulations and thank you for purchasing the Belkin OmniView IP 5216K/5232K Switch with the latest in IP KVM technology. This Switch provides a simple, quick, remote server management solution for medium to large-size businesses. The Switch allows two remote digital users and one local analog user to access and control your servers over the Internet via a standard web browser.
Combine the Switch with the Belkin Central Access Appliance 5000HQ to address the management and administration needs of more users accessing more servers across geographical locations.
The innovative technology in the OmniView IP 5216K/5232K Switch combines hardware and software technology to deliver high- performance remote access, and enables you to troubleshoot servers faster and more efficiently, reducing server downtime and service costs in mission-critical environments.
Belkin’s distinctive technology provides IT professionals:
This User Manual provides all the details you’ll need to install and operate your new OmniView IP 5216K/5232K Switch, in addition to expert troubleshooting advice—in the unlikely event of a problem. For quick and easy installation, please refer to the Quick Installation Guide included in your packaging.
We appreciate your business and are confident that you will soon see for yourself why over 1 million Belkin OmniView KVM products are in use worldwide.

Key Features
Web-Browser Based The Switch allows you to access your KVM switch and all connected servers from any computer connected to the LAN, WAN, or Internet using Firefox® or Microsoft Internet Explorer®.
Out of Band—BIOS-Level Access The Switch allows you to remotely access the basic input/output system (BIOS) of your servers to make changes and perform reboots, regardless of network connectivity or server condition.
User-Friendly Interface The web-based interface allows you to set up and change the Switch’s functions quickly and easily through your web browser, without having to install additional software onto your servers.
Remote Serial Access The Switch provides support for up to two serial devices, such as a managed power distribution unit (PDU), so you can remotely perform hard reboots of your servers.
High-Performance Remote Access

Virtual-Media Technology The Switch provides virtual-media support for up to two servers. This allows the remote user to copy files from a USB or CD-ROM drive to a target server that may be anywhere in the world. Or boot a remote server from a local USB or CD-ROM drive.
Enhanced Security The IP device provides 128-bit Secure Sockets Layer (SSL) authentication and password protection to prevent unauthorized access to your servers and protect data transferred over the Internet. The data communication is also protected with AES 256-bit encryption.
Scalable Centralized Management Additional Switches can be added as your data center grows and the entire inventory can be managed under the Belkin Central Access Appliance 5000HQ. This is ideal for corporations operating servers at multiple sites such as testing labs, campuses, branch offices, and multi-floor facilities.
Video Resolution The Switch supports video resolutions of up to 1600x1200@75Hz for both local and remote consoles.
Flash-Upgradeable Flash upgrades allow you to obtain the latest firmware updates for your Switch. These firmware updates ensure that the Switch is compatible with the latest devices.

System Contents
Remote-Client Browser The Switch may be accessed remotely over a TCP/IP connection from computers using the following web browsers and OS platforms:
Host Computer Operating-System (OS) Platforms The Switch is compatible with CPUs running on, but not limited to, the following OS platforms:
Linux (major distributions only)
**Firefox support may require a firmware upgrade. Visit www.belkin.com/support for more information.
Server Interface Modules Connecting the Switch to a server requires a custom Belkin OmniView SMB Server Interface Module and a standard CAT5 patch cable.
*USB server interface module required

Terminology
OmniView SMB Server Interface Modules: F1DP101A-AP (PS/2 style) F1DP101A-AU (USB style) F1DP101A-AS (Legacy Sun, miniDIN8 style) F1DP101A-AP-8PK (PS/2 style, 8-pack) F1DP101A-AU-8PK (USB style, 8-pack)
Below are some terms and their meanings used in this guide.
CAT5 Cables Belkin highly recommends you use Belkin Category 5e, FastCAT™ 5e, or Category 6 Patch Cables for your OmniView IP 5216K/5232K Switch to help ensure the superior performance of your video. These Cables offer the highest quality possible to ensure optimal data and video transmission.

Unit Display Diagrams
CF:8CLJ<I
Figure 1 illustrates the front panel of the OmniView IP 5232K Switch.
MD) GFN<I (''$)+'M8:,'&-'?q
Figure 2 OmniView IP 5232K Switch – rear view
Figure 1 OmniView IP 5232K Switch – front view



Pre-Installation Guidelines
Mechanical loading Mount the equipment in the rack in such a way that a hazardous condition is not achieved due to uneven mechanical loading.
Circuit overloading When connecting the equipment to the supply circuit, consider the effect that overloading of circuits might have on over-current protection and supply wiring.
Reliable electrical grounding of rack-mounted equipment should be maintained. Provide attention to supply connections other than direct connections to the branch circuit (e.g., use of power strips).
Elevated operating ambient temperature The operating ambient temperature of the rack environment may be greater than the room ambient when installing into a closed or multiunit rack assembly. Install the equipment in an environment compatible with the maximum rated ambient temperature.
Reduced airflow Install the equipment in a rack in such a way that the amount of airflow required for safe operation is not compromised. Leave a gap of at least 5cm/2 inches on each side of the Switch.

Rack-mounting the SMB IP KVM Switch
Place the brackets toward the front of the unit so that the unit can be mounted front facing; or place the brackets toward the rear of the unit so that it can be mounted rear facing on the back of a rack. Figure 4 illustrates the bracket connected for rear facing. Screw the bracket to the Switch using the screws provided.
Rack-mount the Switch using the supplied rack-mount kit. The brackets can be placed in two possible positions (see Figure 3).


Figure 3 Bracket positions
Figure 4 Bracket connected

Connecting the System

Figure 5 Switch’s system overview

The Server Interface Modules (SIMs)
Each computer/server is directly connected to the Switch via the appropriate SIM using CAT5 cables in a star configuration. No external power is needed at the remote SIMs. The SIMs draw their power from the computer’s keyboard port (PS/2 SIM) or from the USB port (USB SIM). The figures below illustrate the SIM PS/2 and USB.


Figure 6 USB SIM2 (part no. F1DP101A-AU)
Figure 7 PS/2 SIM (part no. F1DP101A-AP)





Setting the IP Address
By default, the Switch boots with an automatically assigned IP address from a DHCP (Dynamic Host Configuration Protocol) server on the network. The DHCP server provides a valid IP address, gateway address, and subnet mask.

You can identify the IP address from the OSD at the local position. You can set the IP address locally via the OSD where there is no DHCP server as follows:

Figure 11 Settings window
In the Settings window, navigate downward using the Tab key. At the bottom of the window, press “Tab” to go to the top of the window. Change settings by typing in the selected area or by pressing the space bar—whichever is relevant.
Figure 10 OSD Main window

Changing the network parameters Enable DHCP – When a DHCP server is active on the same network to which the Switch is connected, DHCP provides automatic IP assignment.
When DHCP is disabled (Recommended) – You can assign a fixed IP address to the Switch.
Consult your network administrator regarding the use of the DHCP. When DHCP is disabled, enter the IP Address, Subnet Mask, and Gateway as given by your network administrator.
Once the IP address is satisfactory, log in to the web interface to complete the configuration, as explained in the next section. (Network parameters can also be changed from the remote GUI as explained on page 17).

Logging In to the Web Interface
SSL certificate notes
Client computer operating system. Windows 2000 or higher, with Internet Explorer 6.0 or later version. 128-bit encryption support is required.
When first connecting, two browser security warnings appear. Click “Yes” to proceed.
The first warning disappears upon the first Switch client installation, when Belkin’s root certificate is installed.
Windows Vista Note! To log in to the web configuration interface with Windows Vista, run Internet Explorer as “administrator.” To do this, right-click the Internet Explorer icon on the task bar and select “Run” as “administrator.” See figure below.
On first connection, install the Belkin certificate and ActiveX control. You must be logged in as an administrator on your computer to install the ActiveX control. Once the ActiveX control is installed, all types of users can log in.

Figure 12 Select Run as administrator

Logging in

To complete the initial setup via the web configuration interface:

Figure 14 Targets page
By default, an administrator can access all connected Targets, so they all appear on the Targets page.
Figure 13 Login page
Columns:
Server Name – The server name can be changed in the configuration settings to give the server an identifiable name.
Port Status – Port status can be on, off, or busy (i.e., another user is accessing the server).
Current User – The current user (if any) who is accessing the target.

Connecting to a target server
Network > Configuration
To connect to a target, click the desired target in the Server Name column. The screen of the target appears inside the remote console window. The “Accessing a Target Server” section on page 28 explains how to conduct a remote session. The following sections first explain how to configure the system.
Consult your network administrator for the network settings if necessary.
Device Name – Type a name for the Switch.
TCP Ports – Choose any three TCP ports between ports 800 to 65535. When the Switch is a standalone system, the ports do not have to be consecutive. (The port numbers can be changed from Central Access Appliance, if needed.)
Configuring the system includes setting network parameters, user and security settings, and maintenance.
From the menu, click “Configuration”. The “Network > Configuration” page, including the Configuration menu, appears:

For client computer access from a secured LAN, the selected ports should be open for outbound communication.
Figure 15 Network > Configuration page

LAN
OmniView IP Central Access Appliance 5000HQ
Under LAN in Figure 14, is the following:
OmniView IP 5000HQ is a centralized, IP-based system for secure control of servers and network devices, power, and user administration in the datacenter environment. The 5000HQ combines out-of-band, KVM-via-IP access with modern IT standards and requirements. It is the most comprehensive remote server maintenance solution available in the market today.
Enable DHCP – When a DHCP server is active on the same network to which the Switch is connected, DHCP provides automatic IP assignment.
When DHCP is disabled (Recommended) – You can assign a fixed IP address to Switch.
Enable OmniView IP 5000HQ – Check this option to allow the Switch to be remotely managed by Central Manager Appliance 5000HQ.
Consult your network administrator regarding the use of the DHCP.
When DHCP is disabled, enter the IP Address, Subnet Mask, and Default Gateway for LAN, as given by your network administrator. These parameters can be configured locally from the OSD as explained on page 14.
Manager Auto Discovery – When checked, 5000HQ automatically detects the Switch if it resides on the same network segment.
Manager IP – If the Switch resides on a different segment, type the static IP address of the 5000HQ management appliance. (We advise typing the static IP address of the 5000HQ management appliance even if the Switch resides on the same network segment as the 5000HQ management appliance.)

Administration > User Settings
Administrator An administrator has unrestricted access to all windows and settings and can “take over” any active session. An administrator can change the name and password and target server permissions of all users.
From the menu, click “User Settings” and Figure 16 appears.

User A user can access/control permitted target servers, but cannot use the advanced mouse settings.
A user has no access to the web-configuration interface.
View only “View only” can view the screen of the currently accessed target server without keyboard and mouse control. A “view only” indicator appears on the viewer’s local mouse pointer.
Figure 16 User Settings
On this page, an administrator creates and edits users.
There are three levels of user access:



Administration > Server Name Edit
Give the servers connected to the Switch unique names, so that users accessing the system can identify the servers easily.
To do so:
Where you have a serial device connected to the system, you must configure the serial (RS232) settings.

To do so:
From the menu, click “Serial Settings”. The Serial Settings page will appear (see Figure 18).

Figure 18 Serial Settings
For each serial device connected, type a device name and choose the correct device parameters.
Figure 17 Switch Configuration

Administration > Server Access List
By default, access is allowed to all servers for administrators. For other users, define the access rights of each user separately.
To do so:

Figure 19 Server Access List Configuration

Security > Settings
For local and remote users, you have the option of a standard or high security level of password. The table below shows the parameters of the two options.
Configure the security features, such as Account Blocking, Password Policy, and Idle Timeout, as explained below.
From the Security section, click “Settings”. The “Security > Settings” page appears (see Figure 20).
Standard security policy High security policy
8 characters or more, must include at least 1 digit and 1 uppercase letter, and 1 “special” character as follows: !@#$%^*()_-+=[]’:;?/

6 characters or more
Must not include the user name Must not include the user name
Check the box to enable the high security password policy. If left unchecked, the standard security policy applies.
OSD password enabled – For the local user, access to the OSD can be password enabled or disabled (default), with the option of a standard or high security level of password as explained above. Select the check box to enable password.
Figure 20 Security Settings
Security Settings fields:
Idle Timeout – Select the timeout inactivity period after which the user is disconnected from the system. Choose “No Timeout” to disable timeout.
Account Blocking – Decide on the number of attempts to log in with a wrong user name or password, after which there is a time lock or a total block.
Click to save any security changes.
Password Policy

Security > SSL Certificate
Maintenance > Switch Upgrade
You can install an SSL certificate.
Upgrade the Switch firmware to take advantage of new features. Download the firmware from the support section of Belkin’s website at www.belkin.com/support Save the firmware file on the client computer.
To do so:
From the menu, select “SSL Certificate”. The Install SSL Certificate page appears (see Figure 21).
From the menu, select “Switch Upgrade”. The Upgrade window will appear, showing the current firmware version (see Figure 22).


Figure 22 Firmware Upgrade
Figure 21 Install SSL Certificate page
Certificate File – Browse to locate the “cer” file (.ssl format).
Private Key File – Browse to locate the “private key” file (.pem format).
Key Password – Type the key password.
Click . The certificate installs. The device restarts automatically.
Depending on the type of firmware upgrade type, the following settings may be erased: user settings, server names, and mouse and video adjustments. For more information, refer to the firmware release notes.
The network settings will remain intact.



Set Time and Date
Back Up and Restore
The time and date set feature is used when recording log events. To set the time and date:
You can back up all configuration data to restore it at a later date. To do so:
From the menu, select “Time & Date” and Figure 25 appears.
From the menu, select “Backup & Restore” and Figure 26 appears.


Figure 26 Backup & Restore
Figure 25 Set Time & Date
To back up the configuration data, click to save the file.
To restore the configuration data, browse to locate the file and press . The device restarts.
Type the appropriate parameters.

Saving Changes and Logging Out
To save any configuration changes, click the relevant button on the current page. This could be or just .
To restart the Switch, press .
To exit the Configuration menu and close the session, click .
Only one administrator can log in to the Configuration area at a time. After the idle timeout (see the “Security > Settings” section on page 23), the session terminates.

On the remote console you have the following:
Server name – The currently accessed server identity can be checked any time by looking at the “Server name” on the Internet Explorer title bar.
Log in to the web interface, as explained on page 16. The web interface opens at the Targets page (see Figure 14 on page 16). To connect to a target or serial device, click the desired target/device in the Server Name column. (A server being used by another user cannot be accessed.) The screen of the target/device appears inside a remote console window.
Toolbar icon – This is the minimized toolbar from which you switch and configure the system.
Remote Session icon – Hold the mouse over the icon to view information about current server, connection time, and video mode.
NOTE: If a user connects to a target device with a higher screen resolution than the local computer, the remote viewer window will display a portion of the target device screen, with scroll bars for viewing the remainder of the screen. The user may view the entire screen by adjusting the resolution on the target device, the local computer, or both.

Figure 27 Remote Console window

Changing the performance settings
To maximize the toolbar:
You can alter the bandwidth settings from the toolbar.
Click the arrow . Click again to minimize the toolbar.
To alter the settings:
When maximized, the toolbar can be dragged and dropped to anywhere on the screen, by dragging the icon . When minimized, the icon glides to a side of the screen.
From the toolbar, click . The “Settings...” dialog box appears (see Figure 28).
To hide the toolbar, either:

Double-click the Switch system tray icon .
Press “F9”.
To display the toolbar, repeat the action above. Also see page XX.
To connect to a different server:
Figure 28 Settings.. Dialog box
or

Adjusting the video settings
Choose from the following options:
To change the video settings:
Adaptive – Automatically adapts to the best compression and colors according to the network conditions. (Not recommended because network parameters may change frequently, impacting on user experience.)
From the toolbar, click . You have the following options:
Low – Select “Low” for high compression and 16 colors.
Medium – Select “Medium” for medium compression and 256 colors. Medium is recommended when using a standard Internet connection.
Each option is explained below.
High – For optimal performance when working on a LAN, select “High”. This gives a low compression and high colors (16-bit).
Custom – You can choose your own compression and color levels.
Click “OK”. The screen of the last accessed target server appears.
Select “Refresh” to refresh the video image. Refresh may be needed when changing the display attributes of a target server.


Use the manual video adjustment for fine-tuning the target server video settings after auto adjustment. This feature should also be used for adapting to a noisy environment, a non-standard VGA signal, or when in full-screen DOS/CLI mode.
To adjust the video manually:
Click “Manual Video Adjust”. The manual controls appear (see Figure 29). A red frame also appears around the screen. This represents the screen area according to the server’s screen resolution. Perform the adjustments inside and relative to this frame.
Brightness/Contrast – Use the scales to adjust the brightness and contrast of the displayed image. Move the sliders to change the displayed image. Click in the area of the sliders for fine-tuning.
For the following controls, choose the appropriate measurement.
Horizontal Offset – Defines the starting position of each line on the displayed image.
Vertical Offset – Defines the vertical starting position of the displayed image.
Phase – Defines the point at which each pixel is sampled.
Scale – Defines the scale resolution of the session image.
Select Filter – Defines the filter of the input video from the server. A higher filter reduces the noise level, but makes the image heavier.
Noise Level – Represents the video “noise” when a static screen is displayed.
Figure 29 Manual Video
Adjustments controls


To adjust the video automatically:
Click “Auto Video Adjust”. The process takes a few seconds. If the process runs for more than three times, there is an abnormal noise level. Check the video cable and verify that no dynamic video application is running on the target server’s desktop.
Perform the procedure where necessary for each target server or new screen resolution.
Click . A list of defined keyboard sequences appears. When clicked, these transmit directly to the target server, and will not affect the client computer.
Figure 30 Special Key Manager box
For example, select “Ctrl-Alt-Del” to send this 3-key sequence to the target server to initiate its shutdown/login process.
To add a predefined sequence:
To add a keyboard sequence:
Click “Add/Remove”. The Special Key Manager box appears (see Figure 30).





When accessing the target server, the mice may appear at a distance to each other.
To align the mouse pointers:
From the toolbar, click “ / Align” or press (left) “Ctrl+M” simultaneously. The mice will align.


If the mouse settings on the target server were ever changed, or when the operating system on the target server is Windows XP, 2003 Server, Vista, or 2008 Server, or Linux, Novell, SCO UNIX®, or Sun Solaris, you must configure the mouse manually.
To manually configure the mouse:
Click “OK”. The mouse pointers should be synchronized. There will be no need to perform this setup unless you change the server attached to the particular port.

Figure 32 Mouse Settings Dialog box


Click and the “Mouse Emulation” dialog box appears (see Figure 33).

Figure 34 Mouse Emulation dialog box for use with touch pads
Press “OK” to save settings.
This “Mouse Emulation” setting is used to determine the correct reset sequence for a local mouse. Setting it incorrectly may lead to a jumpy or non-operational local console mouse after a remote user disconnects it from the Switch.
Figure 33 Mouse Emulation dialog box
Max Rate - This defines the maximum mouse report rate. For Sun Solaris, the default value is 20 in order to support older Sun versions.
If a 2-button mouse (older mice without wheel capability, most of the touch pads, trackballs, or integrated keyboards with mice used in most of the rack drawers) is connected to the local KVM port of the Switch, set the “Mouse Emulation” to “Standard Mouse” (see Figure 34).

Adjustments in general
A target server may have a different mouse pointer speed to the client computer. Calibrating automatically discovers the mouse speed of the target server and aligns the two pointers.
The above adjustments, namely:
To perform the calibration when the target server’s operating system is Windows NT® 4, 2000, or 98:
From the toolbar, click “ / Calibrate”. The Switch saves this alignment so calibration is only needed once per target server.
If the video noise level is above zero, calibration may not work. Go to “Video Adjustment” and try to eliminate the noise by pressing “Auto video adjust” and/or adjusting the bars in manual video adjust. Then perform the mouse calibration.
may have to be performed twice for each target.

Hide Toolbar – Check this option to hide the toolbar from the next reconnection onward. To toggle the toolbar on and off, press “F9” or double-click the system tray icon .
Right-click the globe icon and a menu appears. From this menu you can access the connected devices. You also have the following features:
Full-Screen Mode – Check this option to make the remote session screen appear in full-screen mode from the next reconnection onward. To toggle the full-screen mode on and off, press “F11” (also see the next section).
Disconnect – You can disconnect the session by clicking “Disconnect”.
About – Click “About to verify the Client, Firmware and Switch” file versions installed on your Switch.
Virtual Media – Click this option to mount virtually any removable mass storage devices connected to the client computer onto the target server.
Local Settings – Click “Local settings” and the “Client Configuration” dialog box appears (see Figure 35).

Figure 35 Client Configuration dialog box
Pointer Type – From the drop-down menu, you can change the client computer mouse pointer to appear as a dot or to not appear at all.

With virtual media, you can virtually mount removable mass storage devices connected to the client computer onto the target server.
This includes:

Setup Virtual media is only supported by server ports 1 and 2. You must connect a separate USB cable to VM ports 1 and 2 located on the back of the Switch and match to the corresponding servers connected to server ports 1 and 2. 2. Select the device to be mounted and click “Mount”. A remote device warning should appear.
Figure 36 Virtual Media
Mounting a Drive

Mounting an ISO file
An ISO image (.iso) is a disk image of an ISO 9660 file system, and refers to any optical disc image, even a UDF image. In addition to the data files in the ISO image, it also contains all the file system metadata, including boot code, structures, and attributes. All of this information is contained in a single file. These properties make it an attractive alternative to physical media for the distribution of software that requires this additional information as it is simple to retrieve over the Internet.
To mount an ISO file, click “Mount ISO File”, locate the file, and mount it.
Things to know about operation of the virtual media
Because virtual media emulates USB 1.1 over a TCP connection, it has a number of limitations that govern the virtual-media compatibility and operation.

Disconnecting the remote session
Work on the target server as if you are working on a local computer with full-screen mode.
To disconnect the session, click on the toolbar. The Login page appears. You can re-log in, or close the browser window to disconnect the session.
To work in full-screen mode:
When logging in to the system as an administrator or a user, you reach the Targets page (see Figure 14 on page 16). From the menu, you can:
To exit full-screen mode:
Press “F11”, or place the mouse at the top of the window to display the Internet Explorer toolbar and click the “Restore” button.


To change the password, click “Password” from the menu and the following appears.

Figure 37 Events log
Navigate through the event pages using the forward or backward arrows, marked as (A) in Figure 37.
From the drop-down menu, marked as (B) in Figure 37, choose the number of events that will appear on each page (10–40).
Type a new password according to the password policy set (see page 19).
Event log
You can download and save the log.
To see a log of all system events:
To do so, click and save as a “.csv” file. The file can be viewed using Microsoft Excel® or compatible software.
From the menu, select “Event Log” and the following screen appears.
To clear the log, click . A prompt appears asking if you first want to save the log.
Figure 36 Password

Navigating the OSD Main window
This section explains how to operate the Switch locally via the OSD.
To navigate up and down, use the up and down arrow keys.
To exit the OSD, press “Esc”.
To display the OSD:
To select a computer:.
Or, type the 2-digit port number of the desired computer.
Figure 38 OSD Main window



The Settings window – F2
5000HQ MNG – Press the space bar to toggle between enabling and disabling management by the 5000HQ. When enabled, the Switch is remotely managed by OmniView IP Central Management Appliance 5000HQ.
Press “F2”. The Settings window appears (see Figure 40).
5000HQ ADD – Here you can change the static IP address of the 5000HQ.
HOT KEY – Pressing “Scroll Lock” twice in quick succession will make the OSD appear. You can replace “Scroll Lock” with any of the other hot-key options following:
Figure 40 Settings window
Press the space bar to toggle between options. To display the OSD in the future, press the new hot key.
In the Settings window, navigate downward using the “Tab” key. At the bottom of the window, press “Tab” to go to the top of the window. Change settings by typing in the selected area or by pressing the space bar, whichever is relevant.
KEYBOARD LANGUAGE – Press the space bar to toggle between the language options. It can be changed to French or German.
From this window, you can do the following:
Changing the network parameters from the OSD is explained with the initial configuration in the “Setting the IP Address” section on page 13.

DDC – F10
Saving changes to the settings
Display Data Channel (DDC) is a VESA standard for communication between a monitor and a video adapter.
To save changes to the settings and return to the Main window, press “Esc”.
From the Settings window, input the DDC information of the monitor connected to the Switch into the memories of all connected SIMs when first installing the system.
To input the DDC information:
Press “F10”. “Please wait” flashes a few times and disappears. The monitor’s DDC information is sent to all SIMs.
Update the DDC information in any of the following circumstances:
To update the DDC information, repeat the steps as set out above.

Technical Specifications
Dimensions (H x D x W) 44 x 270 x 431mm/1.7 x 10.6 x 17 in.
Windows, Novell, Linux, Sun Solaris
Power Input 100–240VAC, 0.8A, 50/60Hz
Windows 2000 or higher with IE 6.0 or higher and ActiveX
Operating Temperature 0° C to 40° C/32° F to 104° F
Storage Temperature -40° C to 70° C/-40° F to 158° F
Recommended - resolution should be higher than on the target server
Humidity 80% non-condensing relative humidity
Distance from Switch to SIMs Up to 30m/99 ft.
Video and Mouse Synchronization Both auto and manual modes
VGA - HDD15
KM - USB
Security 128-bit SSL encryption, 256-bit AES encryption
Ethernet – RJ45 – 10/100bps auto-sensing
Power From keyboard port From USB port
Serial – RJ45 x 2
Local KVM Connection – Screen HDD15, Keyboard/ Mouse – 2 USB
Product Weight 100g/0.20 lbs.
Shipping Weight 172g/0.38 lbs.
Weight 2.343kg./5.165 lbs.
Dimensions 65 x 25 x 25mm/0.21 x 0.08 x 0.08 in.

Video Resolution and Refresh Rates

Hz 56 60 65 66 70 72 73 75 76 85 86

Safety
This device contains no serviceable parts. Any servicing of the device must be performed by Belkin International, Inc.
Your feedback is very important to help us improve our documentation. Please email any comments to: techsupp@belkin.com.
Please include the following information: Manual name, part number, and P number.
You may register your product online by going to https://www.belkin.com/registration/
This will assist Belkin in contacting you regarding important information regarding the use of your product.

Information
FCC Statement DECLARATION OF CONFORMITY WITH FCC RULES FOR ELECTROMAGNETIC COMPATIBILITY
We, Belkin International, Inc., of 501 West Walnut Street, Compton, CA 90220, declare under our sole responsibility that the products:
CE Declaration of Conformity
We, Belkin International, Inc., declare under our sole responsibility that the products F1DP216G, F1DP232G, to which this declaration relates, are in conformity with Emissions Standard EN55022 and with Immunity Standard EN55024, LVP EN61000-3-2, and EN61000-3-3.
to which this declaration relates:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense.
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme á la norme NMB-003 du Canada.

Belkin International, Inc. , Limited 2-Year Product Warranty
What this warranty covers.
and tear, erosion, depletion, obsolescence, abuse, damage due to low voltage disturbances (i.e., brownouts or sags), non-authorized program, or system-equipment modification or alteration.
Belkin International, Inc. (“Belkin”) warrants to the original purchaser of this Belkin product that the product shall be free of defects in design, assembly, material, or workmanship.
How to get service.
What the period of coverage is.
To get service for your Belkin product you must take the following steps:
Belkin warrants the Belkin product for two years.
What will we do to correct problems?
Product Warranty.
Belkin will repair or replace, at its option, any defective product free of charge (except for shipping charges for the product). Belkin reserves the right to discontinue any of its products without notice, and disclaims any limited warranty to repair or replace any such discontinued products. In the event that Belkin is unable to repair or replace the product (for example, because it has been discontinued), Belkin will offer either a refund or a credit toward the purchase of another product from Belkin. com in an amount equal to the purchase price of the product as evidenced on the original purchase receipt as discounted by its natural use.
a. The part number of the Belkin product.
b. Where you purchased the product.
c. When you purchased the product.
d. Copy of original receipt.
What is not covered by this warranty?
All above warranties are null and void if the Belkin product is not provided to Belkin for inspection upon Belkin’s request at the sole expense of the purchaser, or if Belkin determines that the Belkin product has been improperly installed, altered in any way, or tampered with. The Belkin Product Warranty does not protect against acts of God such as flood, lightning, earthquake, war, vandalism, theft, normal-use wear

Belkin reserves the right to review the damaged Belkin product. All costs of shipping the Belkin product to Belkin for inspection shall be borne solely by the purchaser. If Belkin determines, in its sole discretion, that it is impractical to ship the damaged equipment to Belkin, Belkin may designate, in its sole discretion, an equipment repair facility to inspect and estimate the cost to repair such equipment. The cost, if any, of shipping the equipment to and from such repair facility and of such estimate shall be borne solely by the purchaser. Damaged equipment must remain available for inspection until the claim is finalized. Whenever claims are settled, Belkin reserves the right to be subrogated under any existing insurance policies the purchaser may have.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
IN NO EVENT SHALL BELKIN BE LIABLE FOR INCIDENTAL, SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR MULTIPLE DAMAGES SUCH AS, BUT NOT LIMITED TO, LOST BUSINESS OR PROFITS ARISING OUT OF THE SALE OR USE OF ANY BELKIN PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
This warranty gives you specific legal rights, and you may also have other rights, which may vary from state to state. Some states do not allow the exclusion or limitation of incidental, consequential, or other damages, so the above limitations may not apply to you.
How state law relates to the warranty.
THIS WARRANTY CONTAINS THE SOLE WARRANTY OF BELKIN. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR, EXCEPT AS REQUIRED BY LAW, IMPLIED, INCLUDING THE IMPLIED WARRANTY OR CONDITION OF QUALITY, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND SUCH IMPLIED WARRANTIES, IF ANY, ARE LIMITED IN DURATION TO THE TERM OF THIS WARRANTY.

Belkin Tech Support US: 800-282-2355 310-898-1100, ext. 2263 UK: 0845 607 77 87 Australia: 1800 235 546 New Zealand: 0800 235 546 Singapore: 65 64857620 Europe: www.belkin.com/support
Belkin International, Inc. 501 West Walnut Street Los Angeles, CA 90220, USA 310-898-1100 310-898-1111 fax
Belkin B.V. Boeing Avenue 333 1119 PH Schiphol-Rijk The Netherlands +31 (0) 20 654 7300 +31 (0) 20 654 7349 fax
Belkin Ltd. Express Business Park, Shipton Way Rushden, NN10 6GL United Kingdom +44 (0) 1933 35 2000 +44 (0) 1933 31 2000 fax
Belkin Ltd. 4 Pioneer Avenue Tuggerah Business Park Tuggerah, NSW 2259, Australia +61 (0) 2 4350 4600 +61 (0) 2 4350 4700 fax
© 2009 Belkin International, Inc. All rights reserved. All trade names are registered trademarks of respective manufacturers listed. Windows, Windows Vista, Microsoft, NT, Internet Explorer, and ActiveX are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.