BEFORE OPERATING YOUR GAS GRILL
dures carefully in this manual prior to barbecue operation. Do this even if the barbecue was dealer-assembled.
DANGER If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open fl ames. 3. Open lid 4. If odor continues, keep away from the appliance and immediately call your gas supplier or your fi re department. Leaking gas may cause a fi re or explosion which can cause serious bodily injury or death, or damage to property.
THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.
WARNING 1. Do not store spare liquid propane cylin- der within 10 feet (3m) of this appliance. 2. Do not store or use gasoline or other fl ammable liquids or vapors within 25 feet (8m) of this appliance.
42377 US 05/01/04 NG US English


DANGER Failure to follow the Dangers, Warnings and Cautions contained in this Owner’s Manual may result in serious bodily injury or death, or in a fi re or an explosion causing damage to property.
Do not store a spare or disconnected liquid propane cylinder under or near this barbecue. Improper assembly may be dangerous. Please carefully follow the assembly instructions in this
manual. After a period of storage, and/or nonuse, the Weber® Built-In side burner should be checked for gas
leaks and burner obstructions before use. See instructions in this manual for correct procedures. Do not operate the Weber® Built-In side burner if there is a gas leak present. Do not use a fl ame to check for gas leaks. Combustible materials should never be within 24 inches of the top, bottom, back or sides of your
Weber® Built-In side burner. Do not put a barbecue cover or anything fl ammable on, or in the storage area under the barbecue.
Built-In side burner barbecue should never be used by children. Accessible parts of the barbecue may be very hot. Keep young children away while it is in use. You should exercise reasonable care when operating your Weber® Built-In side burner. It will be hot
during cooking or cleaning and should never be left unattended, or moved while in operation. Should the burner go out while in operation, turn the gas valve off. Open the lid and wait fi ve
minutes before attempting to relight, using the lighting instructions. Never lean over open side burner or place hands or fi ngers on the front edge of the side burner. Should a grease fi re occur, turn off burner and leave lid closed until fi re is out. Do not enlarge valve orifi ces or burner ports when cleaning the valve or burner. The Weber® Built-In side burner should be thoroughly cleaned on a regular basis. Liquid propane gas is not natural gas. The conversion or attempted use of natural gas in a liquid
propane unit or liquid propane gas in a natural gas unit is dangerous and will void your warranty. Do not attempt to disconnect any gas fi tting while your barbecue is in operation. Use heat-resistant barbecue mitts or gloves when operating barbecue. Keep any electrical supply cord and the fuel supply hose away from any heated surfaces. Combustion byproducts produced when using this product contain chemicals known to the state of
California to cause cancer, birth defects, or other reproductive harm. Do not use this Built-In side burner unless all parts are in place. The unit must be properly
assembled according to the instructions outlined in the “Assembly Instruction” section of the Owner’s Guide.
LIQUID PROPANE GAS UNITS ONLY: Use the regulator that is supplied with your Weber® gas barbecue. Do not attempt to disconnect the gas regulator or any gas fi tting while your barbecue is in
operation. A dented or rusty liquid propane cylinder may be hazardous and should be checked by your liquid
propane supplier. Do not use a liquid propane cylinder with a damaged valve. Although your liquid propane cylinder may appear to be empty, gas may still be present, and the
cylinder should be transported and stored accordingly. If you see, smell or hear the hiss of escaping gas from the liquid propane cylinder:

Warranty Weber-Stephen Products Co. (Weber) hereby warrants to the ORIGINAL PURCHASER of this Weber® gas grill that it will be free of defects in material and workmanship from the date of purchase as follows:
Stainless Steel Lid, 10 years All Remaining Parts, 5 years
when assembled and operated in accordance with the printed instructions accompanying it. Weber may require reasonable proof of your date of purchase. THERE- FORE, YOU SHOULD RETAIN YOUR SALES SLIP OR INVOICE. This Limited Warranty shall be limited to the repair or replacement of parts that prove defective under normal use and service and which on examination shall indicate, to Weber’s satisfaction, they are defective. Before returning any parts, contact the Customer service representative in your region using the contact information sheet provided with your manual. If Weber® confi rms the defect and approves the claim, Weber® will elect to replace such parts without charge. If you are required to re- turn defective parts, transportation charges must be prepaid. Weber® will return parts to the purchaser, freight or postage prepaid. This Limited Warranty does not cover any failures or operating diffi cul- ties due to accident, abuse, misuse, alteration, misapplication, vandal- ism, improper installation or improper maintenance or service, or failure to perform normal and routine maintenance, including but not limited to damage caused by insects within the burner tubes, as set out in this owner’s manual. Deterioration or damage due to severe weather conditions such as hail, hurricanes, earthquakes or tornadoes, discoloration due to exposure to chemicals either directly or in the atmosphere, is not covered by this Limited Warranty.
Storage ■ The gas must be turned OFF at the natural gas supply
when the Weber® Built-In Side Burner is not in use. ■ Check that the areas under the control panel and the
slide out bottom tray are free from debris that might obstruct the fl ow of combustion or ventilation air.
a well-ventilated area. Do not use in a garage, building, breezeway or any other enclosed area. WARNING: Your Weber® Built-In Side Burner shall
not be used under an unprotected combustible roof or overhang. WARNING: Your Weber® Built-In Side Burner is
not intended to be installed in or on recreational vehicles and/or boats. WARNING: Do not use the barbecue within 24
There are no other express warrants except as set forth herein and any applicable implied warranties of merchantability and fi tness are limited in duration to the period of coverage of this express written Limited Warranty. Some regions do not allow limitation on how long an implied warranty lasts, so this limitation may not apply to you. Weber® is not liable for any special, indirect or consequential damages. Some regions do not allow the exclusion or limitation of incidental or con- sequential damages, so this limitation or exclusion may not apply to you. Weber® does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment; and no such represen- tations are binding on Weber®. This Warranty applies only to products sold at retail.
inches of combustible materials, top, bottom, back or sides of the grill. WARNING: The entire cooking box gets hot when in
use. Do not leave unattended. WARNING: Keep any electrical supply cord and the
fuel supply hose away from any heated surface. WARNING: Keep the cooking area clear of
fl ammable vapors and liquids, such as gasoline, alcohol, etc., and combustible materials.
WEBER-STEPHEN PRODUCTS CO. Customer Service Center 1890 Roselle Road, Suite 308 Schaumburg, IL 60195 USA

LOCATING YOUR BUILT-IN SIDE BURNER When determining a suitable location for your Built-In Side Burner installation, give attention to concerns such as exposure to wind, proximity to traffi c paths, and keeping any gas supply lines as short as possible. Never locate the Summit® Built-In Side Burner in a garage, breezeway, shed, under an unprotected overhang, or other enclosed area. Locate the Side Burner and structure so there is enough room to safely evacuate the area in case of a fi re.
24 inches Any Surface
CLEARANCE FROM COMBUSTIBLE SURFACES OR STRUCTURES WARNING: Clearance from the outside walls of the sides and back of the LP Tank Cabinet must be a minimum of 24 inches any surface. Refer to “Typical Gas Supply Installation” before starting installation.
24 inches min. for lid clearance
WARNING: The structure, “island” counter tops and adjacent work areas for the LP Tank Cabinet installation must be built from noncombustible materials only.
BUILT-IN SRUCTURE CUTOUT DIMENSIONS All dimensions are to fi nished surfaces.
WARNING: All counter top fi nished surfaces must be constructed of a noncombustible material.

Test connections All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.1/NFPA 54.
DANGER Do not use an open fl ame to check for gas leaks. Be sure there are no sparks or open fl ames in the area while you check for gas leaks. This will result in a fi re or explosion which can cause serious bodily injury or death, and damage to property.
Provide access for a corrugated gas line depending on the location of the side burner in relation to your main gas supply and regulator position.
Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid possible damage to gas supply lines. Exercise caution when pulling gas lines through built-in structure.
Be sure to secure the side burner unit with non corrosive screws anchored into the fi nished surface of the “island structure”. Replace the plastic plug on the front mounting hole to conceal the screw once side burner is secure.
A 3/8 “ inch stainless steel corrugated gas line should be used to connect the side burner to the regulator accessory coupling. WARNING: Do not use a rubber gas hose.


to regulated gas supply
MOUNTING THE SIDE BURNER Connect the corrugated gas line to the side burner valve located on the back right hand side of side burner.


We recommend that this installation be done by a LICENSED professional. GENERAL SPECIFICATIONS FOR PIPING
If you have any questions, contact Customer Service at 1-800-446-1071
©1997 National Fire Protection Association, Inc., and International Approval Services - U.S., Inc. All Rights Reserved.

Test connections All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.1/NFPA 54.
All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.

DANGER Do not use an open fl ame to check for gas leaks. Be sure there are no sparks or open fl ames in the area while you check for gas leaks. This will result in a fi re or explosion which can cause serious bodily injury or death, and damage to property.
DANGER Do not use an open fl ame to check for gas leaks. Be sure there are no sparks or open fl ames in the area while you check for gas leaks. This will result in a fi re or explosion which can cause serious bodily injury or death, and damage to property.
time you disconnect and reconnect a gas fi tting. Note - All factory-made connections have been thoroughly checked for gas leaks. As a safety precaution however, you should recheck all fi ttings for leaks before using your Summit® Built-In side burner. Shipping and handling may loosen or damage a gas fi tting. You will need: a soap and water solution, and a rag or brush to apply it.
Turn on gas supply. Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak. Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks. WARNING: Do not ignite burners when leak check-
ing.


top view · Regulator

Check: 1) Corrugated gas line-to-Accessory “T” Connection. 2) Main gas Supply to regulator WARNING: If there is a leak a connection(1),

DANGER Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive fl ame-up which can cause serious bodily injury or death.
retighten the fi tting with a wrench and recheck for leaks with soap and water solution. If a leak persists after retightening the fi tting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual. Check: When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.
Lighting the side burner. 1) Open the side burner lid. 2) Check that the side burner valve is turned OFF. (Push the knob down and turn clockwise to ensure it is in the off position.). 3) Turn the gas supply valve on. 4) Push down and turn the side burner control valve to START/HI. 5) Push igniter button and hold until burner ignites. You will hear the igniter sparking.


on a bright sunny day. WARNING: If the side burner does not light:

Replace Igniter Batteries

DANGER Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive fl ame-up which can cause serious bodily injury or death.
Parts required: 1 AA alkaline battery per igniter.
Unscrew igniter button from top of control panel. Remove igniter button and contact spring. Remove old battery and replace with a new AA alkaline battery. Positive end(1) of battery faces up as shown in illustration. Replace spring contact(2) and screw igniter button(3) back down.


on a bright sunny day. WARNING: If the side burner does not light:
To Extinguish Push down and turn each burner control knob clock- wise to the OFF position. Turn gas supply OFF at the source.


WARNING: All gas controls and supply valves should be in the OFF position.


Make sure wire is connected between the igniter and electrode. Adjust igniter electrode to burner. Gap should be 1/8 to 3/16 inch from tip of electrode to burner. Spark should be a white/blue color, not yellow.
Side Burner Ring & Head
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Side Burner does not light. | p.10 | ||
| Flame is low in HIGH position. | p.10 | ||
| Push button ignition does not work. | p.10 | ||
| If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your region using the contact information sheet provided with your manual. | p.10 |