EN
Weber logo
Official user manual

Weber 42377

10 pages·474 KB·Burner·PDF·ENDEFRITNLJA
Weber 42377
Table of Contents 20 sections SUMMIT ® · # 42377 · BUILT-IN NG SIDE BURNER INSTALLATION/OWNER'S GUIDE · Summit ® Built-In NG Side Burner · … ShowHide
Page 1 of the Weber 42377 user manual — pliance without reading the "Lighting" Instructions section of this manual
Page 1 · click to enlarge
Page 1

SUMMIT ®

# 42377

BUILT-IN NG SIDE BURNER INSTALLATION/OWNER'S GUIDE

Weber 42377 — SUMMIT ® diagram (page 1)
Fig. 1

Summit ® Built-In NG Side Burner

THESE ACCESSORIES MAY BE PURCHASED SEPARATELY.

YOU MUST READ THIS OWNERS GUIDE

BEFORE OPERATING YOUR GAS GRILL

WARNINGFollow all leak-check proce-

dures carefully in this manual prior to barbecue operation. Do this even if the barbecue was dealer-assembled.

DANGER If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open fl ames. 3. Open lid 4. If odor continues, keep away from the appliance and immediately call your gas supplier or your fi re department. Leaking gas may cause a fi re or explosion which can cause serious bodily injury or death, or damage to property.

THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.

WARNING 1. Do not store spare liquid propane cylin- der within 10 feet (3m) of this appliance. 2. Do not store or use gasoline or other fl ammable liquids or vapors within 25 feet (8m) of this appliance.

WARNINGDo not try to light this ap-

pliance without reading the "Lighting" Instructions section of this manual

42377 US 05/01/04 NG US English

Page 2 of the Weber 42377 user manual —  WARNINGS
Page 2 · click to enlarge
Page 2

DANGERS & WARNINGS

Weber 42377 —  DANGERS &  WARNINGS diagram (page 2)
Fig. 2

DANGER Failure to follow the Dangers, Warnings and Cautions contained in this Owner’s Manual may result in serious bodily injury or death, or in a fi re or an explosion causing damage to property.

WARNINGS

Do not store a spare or disconnected liquid propane cylinder under or near this barbecue. Improper assembly may be dangerous. Please carefully follow the assembly instructions in this

manual. After a period of storage, and/or nonuse, the Weber® Built-In side burner should be checked for gas

leaks and burner obstructions before use. See instructions in this manual for correct procedures. Do not operate the Weber® Built-In side burner if there is a gas leak present. Do not use a fl ame to check for gas leaks. Combustible materials should never be within 24 inches of the top, bottom, back or sides of your

Weber® Built-In side burner. Do not put a barbecue cover or anything fl ammable on, or in the storage area under the barbecue.

Built-In side burner barbecue should never be used by children. Accessible parts of the barbecue may be very hot. Keep young children away while it is in use. You should exercise reasonable care when operating your Weber® Built-In side burner. It will be hot

during cooking or cleaning and should never be left unattended, or moved while in operation. Should the burner go out while in operation, turn the gas valve off. Open the lid and wait fi ve

minutes before attempting to relight, using the lighting instructions. Never lean over open side burner or place hands or fi ngers on the front edge of the side burner. Should a grease fi re occur, turn off burner and leave lid closed until fi re is out. Do not enlarge valve orifi ces or burner ports when cleaning the valve or burner. The Weber® Built-In side burner should be thoroughly cleaned on a regular basis. Liquid propane gas is not natural gas. The conversion or attempted use of natural gas in a liquid

propane unit or liquid propane gas in a natural gas unit is dangerous and will void your warranty. Do not attempt to disconnect any gas fi tting while your barbecue is in operation. Use heat-resistant barbecue mitts or gloves when operating barbecue. Keep any electrical supply cord and the fuel supply hose away from any heated surfaces. Combustion byproducts produced when using this product contain chemicals known to the state of

California to cause cancer, birth defects, or other reproductive harm. Do not use this Built-In side burner unless all parts are in place. The unit must be properly

assembled according to the instructions outlined in the “Assembly Instruction” section of the Owner’s Guide.

LIQUID PROPANE GAS UNITS ONLY: Use the regulator that is supplied with your Weber® gas barbecue. Do not attempt to disconnect the gas regulator or any gas fi tting while your barbecue is in

operation. A dented or rusty liquid propane cylinder may be hazardous and should be checked by your liquid

propane supplier. Do not use a liquid propane cylinder with a damaged valve. Although your liquid propane cylinder may appear to be empty, gas may still be present, and the

cylinder should be transported and stored accordingly. If you see, smell or hear the hiss of escaping gas from the liquid propane cylinder:

1. Move away from liquid propane cylinder. 2. Do not attempt to correct the problem yourself. 3. Call your fi re department.
Page 3 of the Weber 42377 user manual — WARRANTY
Page 3 · click to enlarge
Page 3

WARRANTY

  • This Weber ® Built-In Side Burner is designed for natural (piped in city) gas only. Do not use liquid propane (LP) bottled gas. The valves, orifi ces and hose are for natural gas only.
  • Do not use with charcoal fuel.
  • Check that the area under the control panel and the bottom tray are free from debris that might obstruct the fl ow of combustion or ventilation air.

Warranty Weber-Stephen Products Co. (Weber) hereby warrants to the ORIGINAL PURCHASER of this Weber® gas grill that it will be free of defects in material and workmanship from the date of purchase as follows:

Stainless Steel Lid, 10 years All Remaining Parts, 5 years

when assembled and operated in accordance with the printed instructions accompanying it. Weber may require reasonable proof of your date of purchase. THERE- FORE, YOU SHOULD RETAIN YOUR SALES SLIP OR INVOICE. This Limited Warranty shall be limited to the repair or replacement of parts that prove defective under normal use and service and which on examination shall indicate, to Weber’s satisfaction, they are defective. Before returning any parts, contact the Customer service representative in your region using the contact information sheet provided with your manual. If Weber® confi rms the defect and approves the claim, Weber® will elect to replace such parts without charge. If you are required to re- turn defective parts, transportation charges must be prepaid. Weber® will return parts to the purchaser, freight or postage prepaid. This Limited Warranty does not cover any failures or operating diffi cul- ties due to accident, abuse, misuse, alteration, misapplication, vandal- ism, improper installation or improper maintenance or service, or failure to perform normal and routine maintenance, including but not limited to damage caused by insects within the burner tubes, as set out in this owner’s manual. Deterioration or damage due to severe weather conditions such as hail, hurricanes, earthquakes or tornadoes, discoloration due to exposure to chemicals either directly or in the atmosphere, is not covered by this Limited Warranty.

Storage ■ The gas must be turned OFF at the natural gas supply

when the Weber® Built-In Side Burner is not in use. ■ Check that the areas under the control panel and the

slide out bottom tray are free from debris that might obstruct the fl ow of combustion or ventilation air.

Operating WARNINGOnly use this barbecue outdoors in

a well-ventilated area. Do not use in a garage, building, breezeway or any other enclosed area. WARNING: Your Weber® Built-In Side Burner shall

not be used under an unprotected combustible roof or overhang. WARNING: Your Weber® Built-In Side Burner is

not intended to be installed in or on recreational vehicles and/or boats. WARNING: Do not use the barbecue within 24

There are no other express warrants except as set forth herein and any applicable implied warranties of merchantability and fi tness are limited in duration to the period of coverage of this express written Limited Warranty. Some regions do not allow limitation on how long an implied warranty lasts, so this limitation may not apply to you. Weber® is not liable for any special, indirect or consequential damages. Some regions do not allow the exclusion or limitation of incidental or con- sequential damages, so this limitation or exclusion may not apply to you. Weber® does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment; and no such represen- tations are binding on Weber®. This Warranty applies only to products sold at retail.

inches of combustible materials, top, bottom, back or sides of the grill. WARNING: The entire cooking box gets hot when in

use. Do not leave unattended. WARNING: Keep any electrical supply cord and the

fuel supply hose away from any heated surface. WARNING: Keep the cooking area clear of

fl ammable vapors and liquids, such as gasoline, alcohol, etc., and combustible materials.

  • Gas Supply Testing
  • Disconnect your Weber ® gas barbecue when the gas supply is being tested at high pressures. This appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
  • Turn OFF your Weber ® gas barbecue when the gas supply is being tested at low pressures. This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at the pressure equal to or less than 1/2 psig (3.5 kPa).

WEBER-STEPHEN PRODUCTS CO. Customer Service Center 1890 Roselle Road, Suite 308 Schaumburg, IL 60195 USA

www.weber.com

  • The natural gas supply is easy to use and gives you more cooking control than charcoal fuel.
  • These instructions will give you the minimum requirements for assembling your Weber ® Built-In Side Burner. Please read the instructions carefully before using your Weber ® Built-In Side Burner. Improper assembly can be dangerous.
  • Not for use by children.
  • If there are local codes that apply to portable gas grills, you will have to conform to them. If there are no local codes, you must conform to the latest edition of the National Fuel Gas Code: ANSI Z 223.1/NFPA54.
Page 4 of the Weber 42377 user manual — WARRANTY
Page 4 · click to enlarge
Page 4

LOCATING YOUR BUILT-IN SIDE BURNER When determining a suitable location for your Built-In Side Burner installation, give attention to concerns such as exposure to wind, proximity to traffi c paths, and keeping any gas supply lines as short as possible. Never locate the Summit® Built-In Side Burner in a garage, breezeway, shed, under an unprotected overhang, or other enclosed area. Locate the Side Burner and structure so there is enough room to safely evacuate the area in case of a fi re.

24 inches Any Surface

CLEARANCE FROM COMBUSTIBLE SURFACES OR STRUCTURES WARNING: Clearance from the outside walls of the sides and back of the LP Tank Cabinet must be a minimum of 24 inches any surface. Refer to “Typical Gas Supply Installation” before starting installation.

24 inches min. for lid clearance

WARNING: The structure, “island” counter tops and adjacent work areas for the LP Tank Cabinet installation must be built from noncombustible materials only.

BUILT-IN SRUCTURE CUTOUT DIMENSIONS All dimensions are to fi nished surfaces.

WARNING: All counter top fi nished surfaces must be constructed of a noncombustible material.

Side Burner Cut out DimensionsTolerances A10 1 " 2+ 1/4" - 1/4" B3 3/4"+ 1/4" - 1/4" C16 1/4"+ 1/4" - 1/4"
Show 5 more labels / short text on this page
Any Surface · Any Surface · 24 inches · Side Burner · 24 inches
Page 5 of the Weber 42377 user manual — WARRANTY
Page 5 · click to enlarge
Page 5
  • BUILT-IN GAS LINE LOCATIONS GENERAL CONSTRUCTION DETAILS
  • Summit ® Built-In side burner unit should be on site before construction begins.
  • All dimensions have a tolerance of plus or minus +/- 1 /4 ” inch.

Test connections All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.1/NFPA 54.

DANGER Do not use an open fl ame to check for gas leaks. Be sure there are no sparks or open fl ames in the area while you check for gas leaks. This will result in a fi re or explosion which can cause serious bodily injury or death, and damage to property.

Provide access for a corrugated gas line depending on the location of the side burner in relation to your main gas supply and regulator position.

Area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid possible damage to gas supply lines. Exercise caution when pulling gas lines through built-in structure.

Be sure to secure the side burner unit with non corrosive screws anchored into the fi nished surface of the “island structure”. Replace the plastic plug on the front mounting hole to conceal the screw once side burner is secure.

A 3/8 “ inch stainless steel corrugated gas line should be used to connect the side burner to the regulator accessory coupling. WARNING: Do not use a rubber gas hose.

Weber 42377 — WARRANTY diagram (page 5)
Fig. 3
Weber 42377 — WARRANTY diagram (page 5)
Fig. 4

to regulated gas supply

MOUNTING THE SIDE BURNER Connect the corrugated gas line to the side burner valve located on the back right hand side of side burner.

Weber 42377 — WARRANTY diagram (page 5)
Fig. 5
Page 6 of the Weber 42377 user manual — GAS LINE PIPING
Page 6 · click to enlarge
Page 6

TYPICAL NATURAL GAS SUPPLY INSTALLATION

GAS LINE PIPING

  • Refer to the piping chart at the bottom of previous page.
  • The corrugated gas line from the manifold is 58 inches long. Do not extend the gas line.
  • We have provided the means to make an SAE 45° fl are connection. Do not use pipe sealant on this connection.
  • If the length of line required does not exceed 50 feet, use a 5/8” O.D. tube. One size larger should be used for lengths greater than 50 feet. Refer to piping chart.
  • Gas piping may be copper tubing, type K or L; polyethylene plastic tube, with a minimum wall thickness of .062 inch; or standard weight (schedule 40) steel or wrought iron pipe.
  • Copper tubing must be tin-lined if the gas contains more than 0.3 grams of hydrogen sulfi de per 100 cubic feet of gas.
  • Plastic tubing is suitable only for outdoor, underground use.
  • Gas piping in contact with earth, or any other material which may corrode the piping, must be protected against corrosion in an approved manner.
  • Underground piping must have a minimum of 18” cover.

We recommend that this installation be done by a LICENSED professional. GENERAL SPECIFICATIONS FOR PIPING

  • Note - Contact your local municipality for building codes regulating outdoor gas grill installations. In absence of Local Codes, you must conform to the latest edition of National Fuel Gas Code ANSI Z223.1/ NFPA54.
  • This grill is designed to operate at 4.5 inches of water column pressure.
  • A manual shut-off valve must be installed outdoors, and be accessible, not in the “built-in” structure. An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line. Caution: If young children are in the area, a locking valve should be considered.
  • Pipe compound should be used which is resistant to the action of liquid propane gas when gas connections are made.
  • The gas connections must be fi rmly attached to rigid, permanent construction.

If you have any questions, contact Customer Service at 1-800-446-1071

Table Maximum Capacity of Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 0.5 psi or Less and a Pressure Drop of 0.3 Inch 10-1 Water Column. (Based on a 0.60 Specifi c Gravity Gas) Nominal Internal Iron Pipe Diameter Size (Inches) (Inches)Length of Pipe (Feet) 102030405060708090100125150175200 1/4 .364 3/8 .493 1/2 .622 3/4 .824 1 1.049 1 1/4 1.380 1 1/2 1.160 2 2.067 2 1/2 2.469 3 3.068 4 4.0263222 49 92 190 350 730 1100 2100 3300 5900 120001815 34 63 130 245 500 760 1450 2300 4100 83001412 27 50 105 195 400 610 1150 1850 3250 68001111 23 43 90 170 350 530 990 1600 2800 5800109 21 38 79 150 305 460 870 1400 2500 510088 7 17 15 31 28 64 59 120 110 250 225 380 350 710 650 1130 1050 2000 1850 4100 380076 14 26 55 100 210 320 610 980 1700 3500 72403025221815 132735646403428 27815211596847259 520285215180160130110 1050590440370320275225 1600890670560490410350 3050165012701050930780650 4800270020001700150012501050 8500470036003000260022001850 1750097007400620054004500

©1997 National Fire Protection Association, Inc., and International Approval Services - U.S., Inc. All Rights Reserved.

Page 7 of the Weber 42377 user manual — CONNECT GAS SUPPLY
Page 7 · click to enlarge
Page 7

TEST CONNECTIONS

Test connections All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of ANSI Z223.1/NFPA 54.

All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.

Weber 42377 — TEST CONNECTIONS diagram (page 7)
Fig. 6

DANGER Do not use an open fl ame to check for gas leaks. Be sure there are no sparks or open fl ames in the area while you check for gas leaks. This will result in a fi re or explosion which can cause serious bodily injury or death, and damage to property.

DANGER Do not use an open fl ame to check for gas leaks. Be sure there are no sparks or open fl ames in the area while you check for gas leaks. This will result in a fi re or explosion which can cause serious bodily injury or death, and damage to property.

  • REGULATOR
  • The regulator should be adequately supported.
  • The regulator must be installed close to the appliance.
  • Each appliance must have a separate regulator.
WARNINGYou should check for gas leaks every

time you disconnect and reconnect a gas fi tting. Note - All factory-made connections have been thoroughly checked for gas leaks. As a safety precaution however, you should recheck all fi ttings for leaks before using your Summit® Built-In side burner. Shipping and handling may loosen or damage a gas fi tting. You will need: a soap and water solution, and a rag or brush to apply it.

CONNECT GAS SUPPLY

1. Uncap the fl are fi tting from the optional side burner connection located at regulator. Note: You must connect your side burner to a Weber ® approved regulator(part number #62434) located at main gas supply. If you do not use a Weber ® approved regulator the Warranty on the Summit ® Built-In Side Burner will be voided. If you have any questions, contact Customer Service at 1-800-446-1071 2) Connect the corrugated gas line to the side burner Connection.

Turn on gas supply. Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak. Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks. WARNING: Do not ignite burners when leak check-

ing.

Weber 42377 — CONNECT GAS SUPPLY diagram (page 7)
Fig. 7
Weber 42377 — CONNECT GAS SUPPLY diagram (page 7)
Fig. 8

top view · Regulator

Page 8 of the Weber 42377 user manual — Side Burner Lighting Instructions
Page 8 · click to enlarge
Page 8

Side Burner Lighting Instructions

Check: 1) Corrugated gas line-to-Accessory “T” Connection. 2) Main gas Supply to regulator WARNING: If there is a leak a connection(1),

Weber 42377 — Side Burner Lighting Instructions diagram (page 8)
Fig. 9 · Side Burner Lighting Instructions

DANGER Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive fl ame-up which can cause serious bodily injury or death.

retighten the fi tting with a wrench and recheck for leaks with soap and water solution. If a leak persists after retightening the fi tting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual. Check: When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

Lighting the side burner. 1) Open the side burner lid. 2) Check that the side burner valve is turned OFF. (Push the knob down and turn clockwise to ensure it is in the off position.). 3) Turn the gas supply valve on. 4) Push down and turn the side burner control valve to START/HI. 5) Push igniter button and hold until burner ignites. You will hear the igniter sparking.

Weber 42377 — Side Burner Lighting Instructions diagram (page 8)
Fig. 10 · Side Burner Lighting Instructions
Weber 42377 — Side Burner Lighting Instructions diagram (page 8)
Fig. 11 · Side Burner Lighting Instructions
CAUTIONSide burner fl ame may be diffi cult to see

on a bright sunny day. WARNING: If the side burner does not light:

1. Turn OFF the side burner control valve. 2) Wait 5 minutes to let the gas clear before you try again or try to light with a match.

Page 9 of the Weber 42377 user manual — Manually Lighting the Side Burner
Page 9 · click to enlarge
Page 9

OPERATING

Manually Lighting the Side Burner

Replace Igniter Batteries

Weber 42377 — Manually Lighting the Side Burner diagram (page 9)
Fig. 12 · Manually Lighting the Side Burner

DANGER Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive fl ame-up which can cause serious bodily injury or death.

Parts required: 1 AA alkaline battery per igniter.

Unscrew igniter button from top of control panel. Remove igniter button and contact spring. Remove old battery and replace with a new AA alkaline battery. Positive end(1) of battery faces up as shown in illustration. Replace spring contact(2) and screw igniter button(3) back down.

1. Open the side burner lid. 2) Check that the side burner valve is turned OFF. (Push the knob down and turn clockwise to ensure that it is in the off position.). 3) Turn the gas supply valve on. 4) Put match in a match holder and strike match. 5) Push down and turn the side burner control valve to START/HI. 6) Hold match holder and lit match by right side of side burner.
Weber 42377 — Manually Lighting the Side Burner diagram (page 9)
Fig. 13 · Manually Lighting the Side Burner
Weber 42377 — Manually Lighting the Side Burner diagram (page 9)
Fig. 14 · Manually Lighting the Side Burner
7. Push igniter button and hold until burner ignites. You will hear the igniter sparking. CAUTION: Side burner fl ame may be diffi cult to see

on a bright sunny day. WARNING: If the side burner does not light:

1. Turn OFF the side burner control valve. 2) Wait 5 minutes to let the gas clear before you try again or try to light with a match.

To Extinguish Push down and turn each burner control knob clock- wise to the OFF position. Turn gas supply OFF at the source.

Page 10 of the Weber 42377 user manual — Side Burner maintenance
Page 10 · click to enlarge
Page 10

SIDE BURNER TROUBLESHOOTING

Weber 42377 — SIDE BURNER TROUBLESHOOTING diagram (page 10)
Fig. 15
Problem Check Cure Side Burner does not light.Is gas supply off?Turn supply on. Flame is low in HIGH position.Is the fuel hose bent or kinked?Straighten gas line. Push button ignition does not work.Does burner light with a match?If match lights burner, check igniter (see below). If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your region using the contact information sheet provided with your manual.

Side Burner maintenance

1. Igniter Wire 2) Burner 3) 1/8 to 3/16 inch gap between electrode and burner

WARNING: All gas controls and supply valves should be in the OFF position.

Weber 42377 — Side Burner maintenance diagram (page 10)
Fig. 16 · Side Burner maintenance
Weber 42377 — Side Burner maintenance diagram (page 10)
Fig. 17 · Side Burner maintenance

Make sure wire is connected between the igniter and electrode. Adjust igniter electrode to burner. Gap should be 1/8 to 3/16 inch from tip of electrode to burner. Spark should be a white/blue color, not yellow.

Side Burner Ring & Head

Show 5 more labels / short text on this page
· Side Burner Grate · Side Burner Cap · Igniter Electrode · Control Knob
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Side Burner does not light. p.10
Flame is low in HIGH position. p.10
Push button ignition does not work. p.10
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your region using the contact information sheet provided with your manual. p.10

Ask about the Weber 42377

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Weber 42377

Be the first to ask — other owners or our team will answer.

Original document

Weber 42377 manual PDF

10 pages·474 KB·Burner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…