Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Description Jet pumps are single stage domestic water pumps designed for pumping potable water in applications where the water is up to 100 feet (deep well pump). A pressure switch is a standard feature. A built-in control valve is available on deep well pumps. Deep well pumps can be mounted to either a pre-charged, conventional type or free standing pressure tank. Unpacking After unpacking the jet pump, carefully inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts. Safety Guidelines This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
This product contains chemicals, including lead, known to the State of California to cause birth defects and other reproductive harm. Wash hands after handling.
when working with pumps.
b. Keep work area clean, uncluttered
limitations and potential hazards. Always install a pressure relief valve to match the system pressure rating and the maximum flow rate.
and properly lighted replace all unused tools and equipment.
c. Keep visitors at a safe distance
from work area.
d. Make the workshop child proof:
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in explosive atmospheres. Pump should only be used with liquids compatible with pump component materials. Failure to follow this warning can result in personal injury and/or property damage.
use padlocks, master switches and remove starter keys.
8. Do not pump chemicals or corrosive liquids. Pumping these liquids shortens the life of the pumps seals and moving parts and will void the warranty. 9. When installing pump, cover the well to prevent foreign matter from falling into well and contaminating the water and damaging internal mechanical pumping components. 10. Always test the water from the well for purity before use. Check with local health department for test procedure. 11. Complete pump and piping system MUST be protected against below freezing temperature. Freezing temperatures could cause severe damage and void the warranty.
Disconnect power and release all pressure from the system before attempting to install, service, relocate or perform any maintenance. Lock the power disconnect in the open position. Tag the power disconnect to prevent unexpected application of power.
Install a screen around the inlet pipe to prevent entrapment of swimmers.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
340006-001 3/09 © 2009 Wayne Water Systems
For parts, product & service information
visit www.waynepumps.com

The function of the tank is to store a quantity of water under pressure. When full, the tank contains approximately 2/3 water and 1/3 compressed air. The compressed air forces the water out of the tank when a faucet is opened. An air volume control automatically replaces air lost or absorbed into the water. The usable water, or draw-down capacity, of the tank is approximately 1/6 of the tanks total volume when operated on a “20-40” pressure setting (Figure 2).
12.Do not run the pump dry or damage will occur and will void warranty. This pump is designed for indoor installation only. Failure to install indoors will significantly increase the risk of injury or death from electrical shock.
20. Where a 2-prong is encountered, replace the plug with a properly grounded 3-prong receptacle in accordance with the National Electrical Code, local codes and ordinances. To ensure a proper ground, the grounding means must be tested by a licensed or certified electrician. 21. Use only 3-wire extension cords that have a 3-prong, ground type plug, and 3-pole receptacles that accept the equipment plug. 22. Use wire of adequate size to minimize voltage drop at the motor. Do not handle pump or pump motor with wet hands, when standing on a wet or damp surface or when standing in water. Fatal electrical shock could occur.
All wiring should be performed by a licensed or certified electrician.
13. For maximum safety, the unit should be connected to a grounded circuit equipped with a ground fault interrupter device. 14. Before installing the pump, have the electrical outlet checked by a licensed or certified electrician to make sure the outlet is properly grounded. 15. Make sure the line voltage and frequency of electrical current supply agrees with the motor wiring. 16. Do not attempt repairs to the electric motor. All repairs to the motor must be completed at a licensed or certified electrical motor repair shop. Do not touch an operating motor. Modern motors are designed to operate at high temperatures.

Pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly. Protector tripping is an indication of motor overloading because of operating pump at low heads (low discharge restriction), excessively high or low voltage, inadequate wiring, incorrect motor connections or defective motor or pump. Pre-Installation
A pre-charged storage tank has a flexible bladder or diaphragm that acts as a barrier between the compressed air and water. This barrier prevents the air from being absorbed into the water and allows the water to be acted on by compressed air at initially higher than atmospheric pressures (pre-charged). More usable water is provided than with a conventional type tank. Pre- charged tanks are specified in terms of a conventional tank. For example, a 20 gallon pre-charged tank will have the same usable water or draw-down capacity as a 40 gallon conventional tank, but the tank is smaller in size (Figure 2).
The water supplies illustrated in Figure 26 are possible sources for water. These water supplies can be divided into two categories:
Water from a lake, stream, pond and cistern. This water is usually not fit for human consumption, but may be suitable for washing, irrigation or other household uses.
The pressure switch provides for automatic operation. The pump starts when pressure drops to a cut-in setting. The pump stops when pressure reaches a cut-out setting.
Water found in the water bearing stratum at various levels beneath the earth. Of all the fresh water found on earth only 3 percent is found on the surface and 97 percent is underground.
Grounded Pin · Grounded Outlet

Slope all inlet piping upwards towards the pump to prevent trapping air. Unions or hose couplings can be installed near pump to facilitate removal for servicing or storage. A rubber hose installed between the water system and the house piping will reduce the noise transmitted to the house.
There are four jet pump/tank assemblies sold as packages (Chart 1).
A new well should be pumped clear of sand before installing the pump. Sand will damage the pumping parts and seal. The draw-down level of the well should not exceed the maximum rated depth for the pump. The capacity of the pump will be reduced and a loss of prime may occur. Installation
Plastic pipe can be used on all installations except 2 in. deep well jet. The 2 in. deep well jet requires 1-1/4 in. galvanized steel pipe and special machined couplings (1-13/16 in. O. D.).
The galvanized steel pipe and the couplings restrict the flow of return water back to the jet unless the couplings are machined.
LOCATION
Select a location as close to the water supply as possible.
Long horizontal pipe runs and an abundance of fittings and couplers decrease water pressure due to friction loss. See Chart 2 to determine the proper pipe size.
Be sure to comply with any state or local codes regarding the placement of the pump. The equipment must be protected from the elements. A basement or heated pump house is a good location. Make sure the pump has proper ventilation. The temperature surrounding the pump is not to exceed 100° F (40°C) or nuisance tripping of the motor overload may occur.
Packer Type Foot Valve
A shallow well jet assembly can be used with the deep well pump when the pump is located 25 feet vertically of the water level. Shallow well installations have only one pipe between the pump and water supply (Figure 3).
This pump is designed for indoor installation only. Failure to install indoors will significantly increase the risk of injury or death from electrical shock.
Piping may be copper, steel, rigid PVC plastic or flexible polyethylene plastic.
Flexible pipe is not recommended on suction pipe (inlet pipe).
The pipe must be clean and free of rust or scale. Use a pipe joint compound on the male threads of the metal pipe. Teflon® tape should be used with plastic threads. All connections must be air tight to insure normal operation.
Well X Pre-charged No
12 P & 30 P Horizontal Conventional Yes
FX Horizontal Pre-charged No

DRIVEN WELL
1-1/4 in. 1-1/2 in.
Inlet: Drive 1 in. 1-1/4 in.
Outlet 3/4 in. 1 in.

Install a screen around the inlet pipe to prevent the entrapment of swimmers.
As an alternative, an in-line check valve can be used with a driven well (Figure 3, Illustration C). The pipe between the check valve and the water level will always be under a vacuum.
Leaking joints or couplings will allow air to leak into the pipe and cause abnormal pump operation. Make sure to use pipe joint compound on all male pipe threads.
3. Lower the jet into the well. Add pipe as needed. Be sure to use pipe joint compound on all male threads. 4. Position the jet 10 - 20 feet below the lowest anticipated water level, but never closer than 5 feet from the bottom of the well, if possible. 5. Install a well seal to support the pipe and prevent surface water and other contaminants from entering the well. 6. Install the horizontal pipe from the well to the pump. Piping from the vertical well pipe to the pump should never be smaller than the well pipes. 7. Slope both pipes upward toward the pump to prevent trapping air. If the horizontal distance exceeds 25 feet, see Chart 2 (on page 5) for the recommended pipe sizes. DUG WELL, CISTERN, LAKE AND SPRING WITH TWO PIPE JET (FIGURE 17)

DUG WELL, CISTERN, LAKE AND SPRING INSTALLATION (FIGURE 17)
Slope the horizontal piping upward toward the pump to prevent trapping air. The pipe must be removed during winter months or protected against freezing.
1. Assemble the foot valve and packer to the jet body. 2. Lubricate the rubber cups with petroleum jelly. 3. Attach the first section of pipe and lower jet into well. 4. Add pipe until the jet is positioned 5 - 15 feet below the lowest anticipated water level. The jet should never be closer than 5 feet from the bottom of the well or sand and sediment may be drawn into the system. 5. With the jet in position, fill the pipes with water to make sure the rubber cups are sealed against inside of the well casing. It may be necessary to move the jet up and down to seat the cups. 6. Install the casing adapter and the horizontal pipes.
Protect the pipe from damage from swimmers and boats.
1. Install a 1-1/4 in. foot valve (not included) to the jet body. A 1-1/4 in. coupling is required to connect the larger pipe to the jet assembly. 2. Connect the 1 in. pipe threads into the smaller opening in the jet body. 3. Lower the jet into the water below the lowest anticipated water level, but never closer than 18 in. from the bottom. Sand or debris may be drawn into the system if the jet is too close to the bottom. 4. Provide protection for the jet and pipes against damage from boats or swimmers if a lake is used for the water supply.
Install a screen around the inlet pipe to prevent the entrapment of swimmers.
DRILLED WELL (4 IN. OR LARGER) WITH TWO PIPE JET (FIGURES 17 AND 4)

Electrical
Risk of electrical shock. This pump is designed for indoor installation only.
Select the proper size wire and fuse (Chart 3). Time delay fuses are recommended over standard fuses for motor circuit protection. All pump motors have built-in automatic overload protection that will prevent damage to the motor due to overheating.
28-30 psi 3/4 HP an 1 HP
Figure 8 - Pre-charged Storage Tank
Do not connect to electric power supply until unit is permanently grounded. Connect ground wire to approved ground then connect terminal provided.
A metal underground water pipe or well casing at least 10 feet long makes the best ground electrode. If plastic pipe or insulated fittings are used, run a wire directly to the metal well casing or use a ground electrode furnished by the power company.
Figure 6 - Horizontal Tank
Air Volume Control Tubing
There is only one proper ground terminal on the unit. The terminal(s) is located under the pressure switch cover, is painted green and is identified as GRD. The ground connection must be made at this terminal (Figure 10).

To Air Volume Control
Figure 9 - Shallow Well Jet
To Drive To Jet Prime To Suction
For shallow wells (25 feet or less), a bolt-on shallow well jet is available as an accessory for deep well pumps. The jet attaches to the front of the pump with the two bolts provided and converts the deep well pump into a shallow well pump. The shallow well jet has a 1 in. NPT inlet and a 1/8 in. NPT opening for an air volume control. For optimum performance, an incline check valve on the inlet side of the shallow well jet is recommended.
Figure 7 - Vertical Tank
1. Install the air volume control on the tank as shown. 2. Connect the copper tube from the air volume control to the 1/8 in. NPT opening directly above the 1-1/4 in. opening on the front of the pump. 3. Install a valve and isolating hose between the system and the house plumbing to aid in pump removal for servicing and for reducing noise transmitted through the house piping. 4. Provide a hose bib (faucet) at the lowest point in the system to drain for service or storage. DEEP WELL PUMP WITH PRE-CHARGED STORAGE TANK (FIGURE 8)
Figure 10 - Electrical Connections
The ground conductor must not be smaller than the circuit conductors supplying the motor.
CHART 3 - RECOMMENDED FUSE AND WIRING DATA - 60 HZ MOTORS


Conventional tanks can be drained by opening an outlet at the lowest point in the system. Remove plug or the air volume control to vent the tank.
Check selector to voltage supply. They must match change if needed.
The voltage of power supply must match the voltage of the pump. The unit has dual voltage motors preset at the factory to 115 volts. The motors can be converted to 230 volts by turning the voltage selector to the desired voltage (see Figure 11). Use needle nose pliers to pull the selector out approximately 1/4 in., rotate and then reinsert in correct position.
Pre-charged tanks force virtually all the water from the tank when system pressure is released. No draining is necessary.
PRIMING THE DEEP WELL PUMP To prevent damage to the pump, do not start motor until pump has been fi lled with water. 1. Remove prime plug. 2. Fill pump and piping completely full of water. 3. Replace the prime plug. 4. Close the control valve (Figure 12) and open a nearby faucet. 5. Start the motor. The pressure inside the pump body will build almost immediately as the pump, jet and piping become completely filled with water. 6. Slowly open the control valve. Water will begin to flow. Continue to open the control valve until maximum flow is achieved. Opening the valve too far will cause the water to stop flowing. 7. Adjust the valve until there is a steady flow of water. The valve should be opened as much as possible without losing pressure. 8. Let the system operate for several minutes to flush all piping. 9. Close the faucets and allow the pump to build pressure in the tank. When the pressure reaches the cut- out setting, the motor will stop. The system is now in operation and will automatically cycle upon demand. Maintenance
If the pump has been serviced, drained or has not been used for some time, be sure there is water in the pump housing (volute) and the piping to the well. There must be water in the pump housing (volute) at all times when the pump is running to avoid internal damage of seal members (See Priming the Shallow Well or Priming the Deep Well Sections).

When a tank system has an inadequate ratio of air and water, the pump will start and stop often and erratically.
Disconnect power and release all pressure from the system before attempting to install, service, relocate or perform any maintenance. Operation
1. Disconnect the power to the pump. 2. Open the lowest faucet in the system to release all pressurized water in the system. 3. Prime the pump (See Priming the Shallow Well or Priming the Deep Well Sections). 4. Reconnect the power to the pump. NOTE: As the pump refills the tank with water, the air volume control supplies the tank with the correct air to water ratio for the system to operate. If the air volume control is good, the pump will shut off at the desired cut-off and will be adjusted correctly.
To prevent damage to the pump, do not start motor until pump has been filled with water.

Disconnect power and release all pressure from the system before attempting to install, service, relocate or perform any maintenance. Lock the power disconnect in the open position. Tag the power disconnect to prevent unexpected application of power.
If a pre-charged tank becomes waterlogged, the bladder is normally leaking or broken.
Protect the pump from freezing during winter conditions.
DRAINING THE PUMP Drain openings are provided on all models. To drain the pump: 1. Remove drain plug and prime plug to vent the system. 2. Drain all piping to a point below the freeze line.

2. Carefully slip seal plate over shaft so as not to disturb seal position in seal plate. The seal plate must be orientated during assembly so that the two holes are on a horizontal line across the motor shaft and the (4) locating pins on the back of the seal plate line up with the tabs on the motor housing (Figure 15). This placement should be done to ensure proper draining and priming. 3. Place rotating shaft seal member in position on impeller and press into place. Take care not to press against polished seal surface. 4. Position impeller on shaft and tighten securely (Figure 16).
Some air is lost through the bladder in any tank. To prevent tank failure, check the tank pre-charge on a yearly basis.

The bearing used in the pumps are lifetime lubricated at the factory and require no additional lubrication.
Figure 14 - Removing Shaft Seal and Ceramic Seat
Turn disconnect switch to “off” position.
Before handling shaft seal parts wipe hands clean. Dirt or grease can damage the seal.
5. Secure diffuser to seal plate using the two cap screws. Be sure the screws are orientated on a horizontal line as described in Step 2. 6. Carefully position pump housing (volute) gasket over the diffuser onto the seal plate. In all convertible applications the seal ring must also be positioned on the diffuser. In all shallow well applications care must be taken that the o-ring is clean and properly positioned on the venturi. Cleaning and positioning makes a good seal inside the diffuser when assembled. 7. Assemble the pump housing (volute) to the motor using the four cap screws. Be sure the pump housing (volute) gasket is positioned correctly and tighten the screws securely. NOTE: Shaft must rotate freely and motor end cap should be secured before operation.

Figure 15 - Seal Plate Replacement
Screw Holes · Motor Shaft


Figure 17 - Water Supplies
(A) SPRING: A spring that emerges from the ground. Occurs when water in permeable materials is trapped between impermeable material as rock or clay.
SHALE
(B) LAKE, STREAM, POND
(B) LAKE, STREAM or POND: Surface water, unless treated, is usually not safe for human consumption. It may be used for purposes such as washing or irrigation.
(C) DUG WELL: A hole is excavated several feet in diameter to a fairly shallow depth. It is then lined with brick, stone or concrete to prevent cave-in.
(D) DRIVEN WELL: Pipe with a pointed screen is driven into the ground below the water table. The depth is usually less than 50 feet. Available diameters are 1" through 2".
WATER BEARING SAND
TOP SOIL
CLAY
(E) DRILLED WELL: A hole bored into the earth with machinery and lined with pipe. Depths range from a few feet to over 1000 feet. Common well diameters are 2", 3", 4" and 6" for domestic water wells.
(F) CISTERN: An underground tank built to collect rain water from rooftops. The water is not fit for human consumption.
Water Supplies

Symptom Possible Cause(s) Corrective Action
Pump will not run 1. Power off
Motor hums but will not run 1. Voltage does not match selector switch
Overload trips 1. Incorrect line voltage
Pump runs but delivers little or no water
Pump starts and stops too of ten 1. Water logged tank (conventional tank)

- Model number Wayne Water Systems - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.


Output in Gallons Per Hour (GPH)
5 10 15 20 25
910 780 690 580 390
850 720 660 580 390
590 520 480 410 325
366 324 270 228 174
5 10 15 20 25
1140 1014 900 702 558
1140 1014 900 702 558
858 800 756 690 558
600 520 456 390 318
5 10 15 20 25
1260 1140 990 828 630
1218 1140 990 828 630
930 858 786 720 630
618 600 480 400 340
Output in Gallons Per Hour (GPH)
CWS50
CWS75
2 in.
CWS100
CWS100
CWS50
CWS50
CWS50
CWS75
4 in.
470 420 340 280 200
CWS100
CWS100

For three years from the date of purchase, Wayne Water Systems (“Wayne”) will repair or re place, at its option, for the original purchaser any part or parts of its Pond Kit, Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or work man ship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be pre pared to provide the model and serial number when exercising this warranty. All trans por ta tion charges on Products or parts submitted for repair or replacement must be paid by purchaser. This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper main te nance, or failure to operate in accordance with Wayne’s written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IM PLIED WARRANTIES, IN CLUD ING THOSE OF MER CHANT ABIL I TY AND FITNESS FOR A PARTICULAR PUR POSE, ARE LIMITED TO THREE YEARS FROM THE DATE OF PUR CHASE. THIS IS THE EXCLUSIVE REM E DY AND ANY LIABILITY FOR ANY AND ALL IN DI RECT OR CON SE QUEN TIAL DAM AG ES OR EX PENS ES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above lim i ta tions might not apply to you. This limited war ran ty gives you specific legal rights, and you may also have other legal rights which vary from state to state. In no event, whether as a result of breach of contract warranty, tort (in clud ing negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equip ment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s cus tom ers for such damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return authorization and instructions.
DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.