MG24CB MEDIUM DUTY GAS CHARBROILER COUNTER T OP MODEL MODEL MG24CB ML-114634 VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 31025 (3-97) INST ALLA TION & OP.
— 2 — IMPORT ANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
— 3 — T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
— 4 — Installation, Operation and Care of MODEL MG24CB MEDIUM DUTY GAS CHARBROILER COUNTERT OP MODEL PLEASE KEEP THIS MANUAL FOR FUTURE USE GENERAL Vulcan charbroilers are produced with quality workmanship and material. Proper installation, usage and maintenance of your charbroiler will result in many years of satisfactory performance.
— 5 — When installed, minimum clearance from combustible construction must be 6" at the sides and 6" at the rear; minimum clearance from non-combustible construction must be 0" at the sides and 4" at the rear. The installation location must allow adequate clearances for servicing and proper operation.
— 6 — Fig. 2 Fig. 1.
— 7 — LEVELING Place a carpenter's level on top of the charbroiler. Level the charbroiler front to back and side to side by turning the adjustment screw at the bottom of each leg. GAS CONNECTIONS Gas supply connections and any pipe joint compound must be resistant to the action of propane gases.
— 8 — OPERA TION WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE CHARBROILER. CONTROLS Manual gas valves regulate gas flow to the burners to maintain set temperature. BEFORE FIRST USE Clean the protective metal oils from all surfaces of the charbroiler.
— 9 — RED BUTT ON PILO T SHUT OFF V AL VE PILO T ADJUSTMENT SCREW PL-52719 TURNING THE CHARBROILER ON All burners are lit from constantly burning pilots. Turn gas valve control knobs to HI to ignite the burners. TURNING THE CHARBROILER OFF Turn gas valve control knobs to OFF.
— 10 — CLEANING At least once a day, remove the grease pan, empty and wash it out in the same way you would any cooking utensil. "Burn off" the grease build-up on the grate daily or as dictated by use. Always use insulated gloves when handling grates or radiants to prevent burns.
— 11 — MAINTENANCE WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE CHARBROILER. LUBRICATION All valves must be checked and lubricated periodically by your local service agency.
— 12 —.
An important point after buying a device Vulcan-Hart ML-114634 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Vulcan-Hart ML-114634 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Vulcan-Hart ML-114634 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Vulcan-Hart ML-114634 you will learn all the available features of the product, as well as information on its operation. The information that you get Vulcan-Hart ML-114634 will certainly help you make a decision on the purchase.
If you already are a holder of Vulcan-Hart ML-114634, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Vulcan-Hart ML-114634.
However, one of the most important roles played by the user manual is to help in solving problems with Vulcan-Hart ML-114634. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Vulcan-Hart ML-114634 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center