Thank you for purchasing the Belkin Components OmniView ™SE KVM switch. Controlling multiple PCs from one keyboard, mouse and monitor has never been easier!
The OmniView ™SE puts you in control. Compatible with AT and PS-2 style computers, it is loaded with features such as Integrated Mouse Conversion Technology, separate DB25 daisy-chain ports, and an optional 19"(48.3cm) rackmount kit. It has complete keyboard and mouse emulation for error-free boot-ups, plus Microsoft® Intellimouse®
support. The OmniView ™SE is also designed to handle the most demanding resolutions up to 1600 x 1200, without any noticeable degradation in image quality. Switching can be done through convenient front-panel pushbutton, or keyboard “Hot” key commands. And if you wish to control a Macintosh computer, simply add the Belkin MAC Adapter™for even more system control.
OmniView ™SE 4-Port F1D104 9VDC, 600mA power supply F1D065-PWR This manual P72464 Registration card P72009

Console Connectors:
Keyboard: 6 pin Mini DIN female Mouse: 6 pin Mini DIN female (for PS/2 mouse) DB9 male (for spare serial mouse) Monitor: HDDB15 female
Computer Port Connectors:
Keyboard: 6 pin Mini DIN female Mouse: 6 pin Mini DIN female (for PS/2 mouse) DB9 male (for serial mouse) Monitor: HDDB15 male
Dimensions:
Weight: 2.5 lbs (1.1 kg) Operating Temp: 32 to 104 deg. F (0~40 deg. C) Storage Temp: -4 to 140 deg. F (-20 ~ 60 deg. C) Humidity: 0~80% RH, non-condensing


SLAVE INPUT DB25 Daisy-chain port

Keyboard connector · PS/2 mouse · connector



PLEASE FOLLOW THIS INSTALLATION PROCEDURE EXACTLY. NOT DOING SO MAY RESULT IN KEYBOARD AND/OR MOUSE ERRORS, OR FAULTY OPERATION.

DIP switches 1 & 2 set the SCAN_TIME. See the USAGE section regarding this setting
Use this setting if you have only one OmniView™SE
DIP Switches 1&2 set scantime. See page 15 for AutoScan Mode DIP Switch settings.




Back of OmniView ™SE Back of PC

PS/2 Style Keyboard · PS/2 Mouse


6. Connect the first computer's mouse cable to the OmniView ™SE. If using a PS/2 cable (Belkin Part# F2N036-XX), connect one end to the PS/2 mouse port on the computer, and the other end to the PC1 PS/2 mouse port on the back of the OmniView ™SE. If using a serial mouse cable (Belkin Part# F2N209-XX-T), connect one end to a DB9 serial port on the computer, and the other end to the PC1 DB9 serial mouse port on the back of the OmniView ™SE.
Back of OmniView ™SE
F2N209-XX-T for serial mouse
F2N036-XX for PS/2 mouse
7. Connect the first computer's keyboard cable to the OmniView ™SE. If using a PS/2 cable (Belkin Part# F2N036-XX), connect one end to the PS/2 keyboard port on the computer, and the other end to the PC1 keyboard port on the back of the OmniView ™SE. If your computer has an AT-style keyboard port, you will need a PS/2-AT keyboard adapter (Belkin Part# F2N018). If using an AT-cable (Belkin Part# F3A510-XX), connect one end to the AT keyboard port on the computer, and the other end to an AT to PS/2 keyboard adapter (Belkin Part# F2N017). Then, con- nect the adapter to the PC1 keyboard port on the back of the OmniView ™SE.


Back of PC · Back of PC

3 4 5 6
7 8 9 10
The OmniView ™SE has the capability to be daisy-chained to additional units for control over more computers. Up to four OmniView ™SE units can be daisy chained together, whether 2-Port, 4-Port, or a mixture of both. The example above shows two OmniView ™SE 2-Port units and two OmniView ™SE 4-Port units daisy chained together.
Each OmniView ™SE unit is defined as a "BANK." See diagram above for more information. BANK numbers range from 0 to 3 for a total of 4 BANKs. BANK 0 is the MASTER bank, while banks 1 through 3 are slave banks. The MASTER bank is the unit that connects to the console keyboard, mouse, and monitor.
The DIP switches must be set correctly for proper identification and usage. See page 6 for the actual settings. If you are using the OmniView ™SE in a single-unit configuration, it must be set as the MASTER (BANK 0). If it is to be used as a slave unit, then it must be set to any unused unique bank number from 1 through 3.


The OmniView ™SE is designed to be able to cascade with the OmniView ™PRO as well. In such a scenario, it is recommended that the OmniView ™PRO be the MASTER unit, and the OmniView ™SE units be slave units. This is shown in the diagram above. The OmniView ™PRO is an 8-Port, 19" (48.3cm) rackmountable OmniView ™, having the same features as the OmniView ™SE, but adding On-Screen Display. When the OmniView ™PRO is used as MASTER, all of the other OmniView ™units in the chain will benefit from the On-Screen Display of the MASTER OmniView ™PRO.
When the OmniView ™PRO is used as the MASTER unit, 15 more OmniView ™units (SE and/or PRO) can be daisy-chained to the master. Only BANKs 1 to 3 can be used by OmniView ™SE units. BANKs 4 to 15 must be used by PRO units. Daisy-Chaining the OmniView ™SE:

This assumes you already have a MASTER unit (or MASTER and slave units) set-up and working properly. Below is the procedure of daisy-chaining a new slave unit.
❑If the previous unit is the MASTER, then the other end of the cable
connects to the "Master Input/Slave Output" port of the MASTER (such as cable 1 in the diagram above). ❑If the previous unit is a slave, then the other end goes to the "Slave Input"
slave unit will blink. If you have many slave units, you may have to press the BANK/SCAN button a couple of times to cycle through the preexisting slave units before reaching the newly added unit. • Now you can power up the computers connected to the newly added slave unit. After all the computers have booted up, you may need to RESET the MASTER unit again to detect the presence of powered computers on the new slave unit.


Cable 1 · (Bank 0)


Selecting which computer to operate can be done either by the SELECT button, or through keyboard “Hot” key commands. You will notice that after the OmniView ™SE switches to another computer, the mouse will be inoperative for about 1-2 seconds. This is normal operation and ensures that proper mouse synchronization is established.
The SELECT Button:

Pressing the SELECT button cycles you through all the ports, including inactive ports.
1 2 3 4

Pressing the BANK / SCAN button cycles you through all the active BANKs (if there are slave units present) and then puts the unit in AutoScan mode. If the unit is a single MASTER unit, pressing the button immediately invokes AutoScan mode. This is evident by a long BEEP, followed by two short beeps.
Keyboard "Hot” Key commands:
You can also conveniently command the OmniView ™SE to switch ports through simple keyboard key sequences. To send commands to the OmniView ™SE, the SCROLL LOCK key must be pressed twice within 2 seconds. You will hear a beep for confirmation. Below are the different commands:
Switch to PREVIOUS ACTIVE port (on the same BANK)
Switch to NEXT ACTIVE port (on the same BANK)
Switch to the PREVIOUS BANK (by default, selects first active port on that BANK)
Switch to the NEXT BANK (by default, selects first active port on that BANK)
Directly switches to port Y on BANK X. (x={0-3}, y={1-4})


You can switch directly to any port by giving the OmniView ™SE the BANK and PORT numbers. For instance, if you press [SCROLL LOCK] [SCROLL LOCK] [2] [2], the com- puter on PORT 2 of the OmniView ™SE set to BANK 2 will be selected. In the dia- gram below, that is PC # 8. Hence, if you only have one OmniView ™SE, the first key (X) must be "0".
In AutoScan mode, the OmniView ™SE remains on one port for a number of seconds, before switching to the next. Set DIP switches 1 & 2 using the table below according to a SCAN_TIME interval you prefer. If there are slave units present, the SCAN_TIME setting is set on the MASTER unit only, and need not be set on the slave units.

NOTE: There is no mouse or keyboard control in this mode. This is necessary to prevent errors. Otherwise, if the user is moving the mouse or using the keyboard when the OmniView ™SE switches to the next port, data flow is interrupted and will cause erratic mouse movement and/or the wrong characters to show up when using the keyboard.
To get out of AutoScan mode, press the [SPACEBAR].
Enable AutoScan mode

switch is on. • Lower your refresh rate and/or screen resolution settings.
Keyboard Problems: Q: The keyboard is not detected, or a keyboard error is reported during boot-up. A: • Check the cables and make sure they are inserted properly in the correct ports.
Q: The computers boot up fine, but the keyboard does not work. A: • Check the cables and make sure they are inserted properly in the correct ports.
PS/2 Mouse Problems at the Console or Computers: Q: The mouse is not detected during boot-up. A: • Check the cables and make sure they are inserted properly in the correct ports.

Q: The computers boot up fine, but the mouse does not work. A: • Check the cables and make sure they are inserted properly in the correct ports.
Q: When I switch from one port to another, mouse movement is completely
erratic. What do I do? A: • Switch to another port, then switch back to the previous port. This can
Problems with computers using the serial mouse output: Note: The OmniView ™SE has Integrated Mouse Conversion Technology. This
technology converts the PS/2 mouse signals at the console to serial mouse signals. Windows® 9x Control Panel System applet may not display that it has detected a mouse, but the Modem applet will show a serial mouse at a certain serial port.
Q: The computers boot up fine, but the mouse does not work. A: • Switch to another computer port, then switch back. This is another method of

Q: When I switch from one port to another, mouse movement is completely errat-
ic. What do I do? A: • RESET the OmniView ™SE by simultaneously pressing the BANK/SCAN and
Q: The wheel on the Intellimouse® does not work on my computer. Why? A: • The Integrated Mouse Conversion Technology converts only the standard PS/2
signals which are the buttons and the x & y coordinate movement, but not the wheel movement or wheel button. This is because the wheel and wheel button data use non-PS/2 protocol.
Note about the Optional Serial Mouse port at the console: If you have tried all possible troubleshooting methods, you can plug in a serial mouse (as a second mouse) at the optional serial mouse input port. See the Product Detail section, page 4, for the diagram. This mouse will be directly connected to the serial mouse ports on the OmniView ™SE. Note that the serial mouse signals will not be converted to PS/2 mouse signals, so if you have other PCs using PS/2 mouse ports, you must keep the PS/2 mouse at the console. This serial mouse is a second mouse, and is active only when on a computer that uses the serial mouse output.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inter- ference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
CE Declaration of Conformity
We, Belkin Components, declare under our sole responsibility that the OmniView™SE, to which this declara- tion relates, is in conformity with Generic Emissions Standard EN50081-1 and with Generic Immunity Standard EN50082-1 1992.
Belkin Components One Year Product Warranty
Belkin Components warrants this product against defects in materials and workmanship for one year. If a defect is discovered, Belkin will, at its option, repair or replace the product at no charge provided it is returned during the warranty period, with transportation charges prepaid, to the authorized Belkin dealer from whom you purchased the product. Proof of purchase may be required.
This warranty does not apply if the product has been damaged by accident, abuse, misuse, or misapplica- tion; if the product has been modified without the written permission of Belkin; or if any Belkin serial number has been removed or defaced.
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE IN LIEU OF ALL OTHERS, WHETHER ORAL OR WRITTEN, EXPRESSED OR IMPLIED. BELKIN SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
No Belkin dealer, agent, or employee is authorized to make any modification, extension, or addition to this warranty.
BELKIN IS NOT RESPONSIBLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIM- ITED TO LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPROGRAMMING, OR REPRODUC- ING ANY PROGRAM OR DATA STORED IN OR USED WITH BELKIN PRODUCTS.
Some states do not allow the exclusion or limitation of incidental or consequential damages or exclusions of implied warranties, so the above limitations of exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
Contacting Belkin Components · FCC Statement
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.