READ AND SAVE THESE INSTRUCTIONSp.1! INTENDED FOR DOMESTIC COOKING ONLY !p.1WARNINGp.1CAUTIONp.1INSTALLER: Save this manual for Electrical Inspector andp.1PLANNINGp.2TYPICAL INSTALLATIONp.2COUNTER TOPp.2CHIMNEY TOPp.2COUNTER TOP CHIMNEY TOPp.2COOK TOPp.2AIR VENTp.2AIR VENT GEARMOTOR COVERp.2GEAR MOTOR COVERp.210" ROUND DISCHARGE PLATEp.2BOXp.2120 VAC GROUNDED OUTLETp.23-1/4" X 10" DUCT CONNECTORp.210" ROUND DUCTWORKp.2ELECTRICAL SPECIFICATIONSp.2TAKE MEASUREMENTSp.2TAKE MEASUREMENTS (CONTINUED)p.3PLAN THE DUCTWORKp.3LEFT DISCHARGEp.3RIGHT DISCHARGEp.310" ROUND DISCHARGEp.3DOWN DISCHARGEp.3PLATEp.3STRAIGHT DUCT 10" ROUND ELBOWp.3EQUALS 6 FT. OFp.36" ROUND ELBOWp.33-1/4" X 10" TO 6" RD. TRANSITIONp.33-1/4" X 10" 90 O ELBOWp.3EQUALS 2 FT. OF STRAIGHT DUCTp.3EQUALS 8 FT. OFp.3STRAIGHT DUCTp.3PLAN THE CABINET CUTOUTSp.4PLAN THE WIRINGp.5PREPARE THE DOWNDRAFTp.53¼" X 10" DISCHARGEp.5Interior Blower Installationp.5NUTSp.5CLAMP CHANNELSp.5SCREWSp.5COVERp.5GEARMOTORp.5MOTORp.5PLUGp.5ADDITIONALp.5BOTTOMp.5FLANGEp.5Exterior Blower Installationp.6CUT COUNTERTOP OPENINGp.7F Ep.7MOUNTING SCREWS MOUNT THE UNITp.8LEVELING BRACKET - FLANGE FACING OUTp.8LEVELING BRACKET -p.8FLANGE FACING INp.8INSTALL DUCTWORKp.8joists, wall studs, electricalp.8ELBOWp.8COLLAR SCREWSp.86" RD. ELBOW & DUCTWORKp.810" ROUND DUCTp.8INSTALLATION OF REMOTE CONTROL SWITCHp.9TOP EDGEp.91/4" DIA. HOLE 1/4" DIA. HOLEp.91" DIA. HOLEp.9CUT OUT ON DOTTED LINEp.9This page has been leftp.10BACKSIDE OF REMOTE SWITCHp.10TEMPLATEp.10INSTALL ELECTRICAL WIRINGp.11INSTALL COOKTOPp.11OPERATIONp.12All Units UP / DOWN --- Raises and lowersp.12REMOTE CONTROLp.12FOR MODELSp.12VIPR102RSS VIPR162RSS VIPR182RSSp.121 2 3 4 FILTER RESETp.12
Page 1 of the Viking VIPR182 user manual — INSTALLER: Save this manual for Electrical Inspector and
Page 1 · click to enlarge
Page 1

MODEL WIDTH BLOWER (purchase separately) VIPR102 30" VIDV500 Interior or VEDV900 Exterior VIPR102R 30" w/ remote control VIDV500 Interior or VEDV900 Exterior VIPR162 36" VIDV500 Interior or VEDV900 Exterior VIPR162R 36" w/ remote control VIDV500 Interior or VEDV900 Exterior VIPR182 48" VIDV500 Interior, VEDV900 Exterior or VEDV1200 Exterior VIPR182R 48" w/ remote control VIDV500 Interior, VEDV900 Exterior or VEDV1200 Exterior

READ AND SAVE THESE INSTRUCTIONS

! INTENDED FOR DOMESTIC COOKING ONLY !

WARNING

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: 1. SMOTHER FLAMES with a close-fi tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the fl ames do not go out immedi ately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - You may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher, and you already know how to operate it. B. The fi re is small and contained in the area where it started. C. The fi re department is being called. D. You can fi ght the fi re with your back to an exit. a Based on “Kitchen Firesafety Tips” published by NFPA.

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualifi ed person(s) in accordance with all applicable codes and standards, including fi re-rated construction codes and standards. 4. Suffi cient air is needed for proper combustion and exhausting of gases through the fl ue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. To reduce the risk of fi re, use only metal ductwork. 8. Do not install this product with the activating switch directly behind a burner or element. Minimum distance between the switch and the edge of the burner should be 4 inches. 9. Loose-fi tting or hanging clothing should never be worn when operating this appliance. They may be ignited by burners/ elements on cooktop. 10. Children should not be left alone or unattended in the area where this appliance is in use. 11. This unit must be grounded.

!

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. Clean fi lters and grease-laden surfaces frequently. 4. Do not repair or replace any part of this appliance unless specifi cally recommended in this manual. All other servicing should be done by a qualifi ed technician. 5. Please read specification label on product for further information and requirements. 6. DO NOT INSTALL WITH GRILL MODEL RANGETOPS. This will void the warranty. 7. Models VIPR102SS, VIPR162SS, and VIPR182SS (non- remote units): DO NOT INSTALL WITH RANGETOPS. This will void the warranty.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when cooking fl aming foods. c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter. d) Use proper pan size. Always use cookware appropriate for the size of the surface element.

INSTALLER: Save this manual for Electrical Inspector and

Homeowner to use.

HOMEOWNER: Use and Care Information on Page 11.

Page 2 of the Viking VIPR182 user manual — TAKE MEASUREMENTS
Page 2 · click to enlarge
Page 2

PLANNING

This downdraft blower system is designed to be used to exhaust airborne contaminants when cooking with a variety of gas or electric cooktops. It can be mounted in island, peninsula, or conventional wall locations.

TYPICAL INSTALLATION

This downdraft blower system is designed to be used to ex- haust airborne contaminants when cooking with a variety of gas or electric cooktops. It can be mounted in island, peninsula, or conventional wall locations.

TYPICAL INSTALLATION

COUNTER TOP

CHIMNEY TOP

COUNTER TOP CHIMNEY TOP

Viking VIPR182 — TYPICAL INSTALLATION diagram (page 2)
Fig. 1
Viking VIPR182 — TYPICAL INSTALLATION diagram (page 2)
Fig. 2

COOK TOP

COOK TOP

AIR VENT

AIR VENT GEARMOTOR COVER

GEAR MOTOR COVER

This unit can be easily installed following these basic steps:

This unit can be easily installed following these basic steps:

10" ROUND DISCHARGE PLATE

  • Cut out the countertop opening.

BOX

  • Cut out the countertop opening.

120 VAC GROUNDED OUTLET

120 VAC GROUNDED OUTLET

  • Mount the unit in the cabinet.
  • Mount the unit in the cabinet.
  • Install the Model VIDV500 Interior Blower
  • Install 10" round discharge plate

3-1/4" X 10" DUCT CONNECTOR

  • Connect the ductwork and electrical.

10" ROUND DUCTWORK

  • Install Model VEDV900 or VEDV1200 (48" Model ONLY) External Blower
  • Install the cooktop.

ELECTRICAL SPECIFICATIONS

ELECTRICAL SPECIFICATIONS

  • 120 VAC
  • 60 Hz
  • 4.0 A
  • Connect the ductwork and electrical.
  • 120 VAC
  • 60 Hz
  • 6.0 A (max.)
  • Install the cooktop.

TAKE MEASUREMENTS

1. Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. The Models VIPR102SS and VIPR102RSS will fi t in most 30" wide cabinets the Models VIPR162SS and VIPR162RSS will fi t in most 36" wide cabinets and the Models VIPR182SS and VIPR182RSS will fi t most 48" wide cabinets. However, it is recommended that oversized cabinets be used for easier installation.
Viking VIPR182 — TAKE MEASUREMENTS diagram (page 2)
Fig. 3
2. Cooktop depth can vary greatly from one to another. This may cause the fi t of these two appliances to be rather tight.

Pay special attention to the areas of potential interference highlighted above. A countertop with (A) a raised lip and/or (B) a backsplash may not allow enough fl at countertop for a proper installation. Note that 2" of fl at countertop is required behind cooktop and that 1-3/4" is necessary between the back edge of the cooktop and the inside of cabinet back.

Page 3 of the Viking VIPR182 user manual — EQUALS 2 FT. OF STRAIGHT DUCT
Page 3 · click to enlarge
Page 3

TAKE MEASUREMENTS (CONTINUED)

Viking VIPR182 — TAKE MEASUREMENTS (CONTINUED) diagram (page 3)
Fig. 4

PLAN THE DUCTWORK

LEFT DISCHARGE

1. The interior downdraft blower system is designed for use with 3-1/4" x 10" ductwork (can be transitioned to 6" round). Three different discharge directions are available with side-toside adjustment for accurate alignment of ductwork.
Viking VIPR182 — LEFT DISCHARGE diagram (page 3)
Fig. 5
1. The exterior downdraft blower system is designed for use with 10" round ductwork.
Viking VIPR182 — LEFT DISCHARGE diagram (page 3)
Fig. 6
2. For best performance: Plan ducting which has the shortest length of ductwork and a minimum number of elbows. Check location of fl oor joists, wall studs, electrical wiring or plumbing for possible interference.
2. For best performance: Choose the ducting option which allows the shortest length of ductwork

RIGHT DISCHARGE

10" ROUND DISCHARGE

DOWN DISCHARGE

PLATE

and a minimum number of elbows and transitions. Check location of fl oor joists, wall studs, electrical wiring or plumbing for possible interference.

Viking VIPR182 — RIGHT DISCHARGE diagram (page 3)
Fig. 7

STRAIGHT DUCT 10" ROUND ELBOW

EQUALS 6 FT. OF

6" ROUND ELBOW

3-1/4" X 10" TO 6" RD. TRANSITION

3-1/4" X 10" 90 O ELBOW

3. The system will operate most effi ciently when the ductwork does not exceed 40 feet of equivalent duct. The illustration, above, shows equivalent feet of a 10" round elbow. The number of feet of straight duct plus the equivalent feet of elbows to be used should equal 40 feet or less.

EQUALS 2 FT. OF STRAIGHT DUCT

EQUALS 6 FT. OF

EQUALS 8 FT. OF

STRAIGHT DUCT

STRAIGHT DUCT

3. The system will operate most effi ciently when the ductwork does not exceed 40 feet of equivalent duct. The chart, above, shows equivalent feet of elbows and transitions. The number of feet of straight duct plus the equivalent feet of transitions and/or elbows to be used should equal 40 feet or less.
Page 4 of the Viking VIPR182 user manual — PLAN THE CABINET CUTOUTS
Page 4 · click to enlarge
Page 4

PLAN THE CABINET CUTOUTS

Viking VIPR182 — PLAN THE CABINET CUTOUTS diagram (page 4)
Fig. 8
! CAUTIONBEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with fl oor

CENTER LINE OF DUCT CUTOUT (can be located within this area)

Page 5 of the Viking VIPR182 user manual — BOTTOM
Page 5 · click to enlarge
Page 5

PLAN THE WIRING

1. The Interior Downdraft Blower system draws 4 AMPS and requires a 120 VAC, 60 Hz circuit.
1. The Exterior Downdraft Blower system draws 6 AMPS and requires a 120 VAC, 60 Hz circuit.
2. The downdraft has a 2 ft. long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the unit’s power cord to reach.
2. The downdraft has a 2 ft. long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the unit’s power cord to reach.
  • In these cases, the width of the downdraft covers nearly the entire width of the back wall of the cabinet. So you must either:
  • mount the electrical box to a side wall or cabinet fl oor - at least 12 inches from the back wall.
  • mount the electrical box to a wall stud behind the cabinet - where it will not be covered by the downdraft. Then provide a clearance hole in the back wall of the cabinet.
  • In these cases, the width of the downdraft covers nearly the entire width of the back wall of the cabinet. So you must either:
  • mount the electrical box to a side wall or cabinet fl oor - at least 12 inches from the back wall.
  • mount the electrical box to a wall stud behind the cabinet - where it will not be covered by the downdraft. Then provide a clearance hole in the back wall of the cabinet. PLEASE NOTE: External blowers must be hard-wired using locally-supplied wire and connected to the downdraft plug (included).

PREPARE THE DOWNDRAFT

3¼" X 10" DISCHARGE

Interior Blower Installation

The downdraft is shipped without a blower. Purchase a Model VIDV500 Interior Blower and mount it to the downdraft as follows:

NUTS

1. Place the downdraft on its back on a table of fl at work surface.
2. Remove the 4 nuts and 2 clamp channels .

CLAMP CHANNELS

3. Remove 2 screws and the gear motor cover .
4. Carefully position the blower under the bottom fl ange of the downdraft with the 3¼" x 10" discharge pointed in the desired direction.

SCREWS

COVER

GEARMOTOR

MOTOR

PLATE

5. Connect motor plug .

COVER

PLUG

6. Replace the gear motor cover and 2 sheet metal screws.

ADDITIONAL

SCREWS

7. Replace the 2 clamp channels and start the 4 nuts, do not tighten.
8. Slide blower left of right to desired position. Use cover plate (supplied) to close up any open space.
9. Tighten 4 nuts to secure top of blower. Use additional screws (supplied) through bottom fl ange to secure bottom in blower.

BOTTOM

FLANGE

Page 6 of the Viking VIPR182 user manual — BOTTOM
Page 6 · click to enlarge
Page 6

PREPARE THE DOWNDRAFT

10" ROUND DISCHARGE

Exterior Blower Installation

MOTOR

PLUG

PLATE

NUTS

The downdraft is shipped without a blower. Purchase a Model VEDV900 or VEDV1200 Exterior Blower and mount the 10" discharge plate to the downdraft as follows:

CLAMP CHANNELS

1. Place the downdraft on its back on a table of fl at work surface.
2. Remove the 4 nuts and 2 clamp channels .

SCREWS

3. Remove 2 screws and the gear motor cover .

COVER

4. Carefully position the10" discharge plate under the bottom fl ange of the downdraft.

GEARMOTOR

PLATE

COVER

5. Connect motor plug .

ADDITIONAL

SCREWS

6. Replace the gear motor cover and 2 sheet metal screws.
7. Replace the 2 clamp channels and start the 4 nuts, do not tighten.
8. Slide blower left of right to desired position. Use cover plate (supplied) to close up any open space.
9. Tighten 4 nuts to secure top of blower. Use additional screws (supplied) through bottom fl ange to secure bottom of discharge plate.

BOTTOM

FLANGE

Page 7 of the Viking VIPR182 user manual — D
Page 7 · click to enlarge
Page 7

CUT COUNTERTOP OPENING

1. Measure and cut the countertop opening for your width of cooktop and downdraft.
Cooktop Width & Model30" VECU36" VECUVGSU102VGSU16230" VGRT *36" VGRT *48" VGRT * For use with Downdraft ModelsVIPR102SSVIPR162SSVIPR102SSVIPR162SSVIPR102RSSVIPR162RSSVIPR182RSS VIPR102RSSVIPR162RSSVIPR102RSSVIPR162RSS Cutout Dimensions A28-3/4"34-3/4"28-1/16"34-1/4"30"36"48" B20-1/4"20-1/4"18-3/4"18-3/4"24"24"24" C27"33"27"33"27"33"45" D2-1/4"2-1/4"3"3"2-3/4"2-3/4"2-3/4" E7/8"7/8"------1-1/2"1-1/2"1-1/2" F7/8"7/8"1-1/16"1-1/4"1-1/2"1-1/2"1-1/2"

* Must use island trim. Rear countertop trim (supplied with island trim) will be used in this installation.

F E

F

Viking VIPR182 — F E diagram (page 7)
Fig. 9
Viking VIPR182 — F E diagram (page 7)
Fig. 10

D

D

Viking VIPR182 — D diagram (page 7)
Fig. 11
Cooktop Width & Model30" VEC36" VEC30" VGC36" VGC For use with Downdraft ModelsVIPR102SSVIPR162SSVIPR102SSVIPR162SS VIPR102RSSVIPR162RSSVIPR102RSSVIPR162RSS Cutout Dimensions A28-7/8"34-7/8"27-3/4"33-3/4" B19-1/4"19-1/4"18-3/4"18-3/4" C27"33"27"33" D2-11/16"2-11/16"2-15/16"2-15/16"" E15/16"15/16"3/8"3/8" F15/16"15/16"3/8"3/8""

F E

F E

Viking VIPR182 — F E diagram (page 7)
Fig. 12
C Cutout for: VGC Cooktops B AC Cutout for: VGC Cooktops A
Viking VIPR182 — F E diagram (page 7)
Fig. 13

D

D

Page 8 of the Viking VIPR182 user manual — 3-1/4" X 10" TO 6" RD. TRANSITION
Page 8 · click to enlarge
Page 8

MOUNTING SCREWS MOUNT THE UNIT

Viking VIPR182 — MOUNTING SCREWS MOUNT THE UNIT diagram (page 8)
Fig. 14

LEVELING BRACKET - FLANGE FACING OUT

1. Set downdraft into opening. Extend leveling brackets to fl oor of cabinet so downdraft sits straight. (Note: Leveling brackets can be removed and re-attached in other positions. Bottom fl ange may have to face inward in tight cabinet installations.)
2. Secure the downdraft to the countertop as follows: Hold the downdraft against the back of countertop cut-out and tightening the two mounting screws (one on each end of unit) on underside of countertop. Use a wood shim between screw and underside of granite countertops.

LEVELING BRACKET -

FLANGE FACING IN

3. Screw leveling brackets to bottom of cabinet. Tighten screws holding leveling bracket to unit on each side.

INSTALL DUCTWORK

Viking VIPR182 — INSTALL DUCTWORK diagram (page 8)
Fig. 15
! CAUTIONBEFORE CUTTING HOLE IN CABINET FOR DUCTWORK, check for interference with fl oor
Viking VIPR182 — INSTALL DUCTWORK diagram (page 8)
Fig. 16

joists, wall studs, electrical

wiring, or plumbing.

3-1/4" X 10" TO 6" RD. TRANSITION

ELBOW

COLLAR SCREWS

6" RD. ELBOW & DUCTWORK

10" ROUND DUCT

ELBOW

1. Cut hole in cabinet as well as holes in wall or fl oor as necessary.
1. Cut hole in cabinet as well as holes in wall or fl oor as necessary.
2. Mount the roof or wall cap and work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned. Tape all ductwork connections to make them secure and air tight.
2. Mount the exterior blower and work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned. Tape all ductwork connections to make them secure and air tight.
3. Connect ductwork to downdraft. If necessary, LOOSEN nuts and screws that hold remote blower adapter plate in place, and slide outlet assembly left or right to meet ductwork. Re-tighten screws and nuts.
3. Connect ductwork (and transition, if required) to downdraft. If necessary, LOOSEN nuts and screws that hold the blower in place, and slide blower left or right to meet ductwork. Re-tighten screws and nuts.
Page 9 of the Viking VIPR182 user manual — 1/4" DIA. HOLE 1/4" DIA. HOLE
Page 9 · click to enlarge
Page 9

INSTALLATION OF REMOTE CONTROL SWITCH

3. Remove the control from the plastic bag. Remove the paper from the adhesive back of the control, line the control up with the three holes and position the control so it is parallel with the front of the counter top. Press down fi rmly for 60 seconds.

Keep in mind you do not want to place the control where it will be in the way for cooking, or where hot pans could be set, or hot liquids spilled on the control.

4. Remove the two nylon thumbnuts from the plastic bag and thread onto the two studs on the control from below the counter top. Hand tighten only. The thumbnuts just need to be snugged by hand. They are there to hold the control in place until the adhesive sets up.
1. Using the template below, lay out the 3-hole pattern on the counter top. Mark the centers of the three holes to be drilled.
2. Carefully drill the three holes through the counter top. Be careful not to damage or chip the counter top surface when drilling the holes.
5. Remove cable from the plastic bag and plug into back of control from below counter top. Route cable through cabinet to lower right hand corner of downdraft. Plug other end of cable into the downdraft unit. (Receptacle hole for cabinet is on the lower right hand side of the downdraft.)
6. Stuff excess cable out of the way and secure the cable so it is not damaged from items stored in the cabinet.

TOP EDGE

1/4" DIA. HOLE 1/4" DIA. HOLE

1" DIA. HOLE

CUT OUT ON DOTTED LINE

Page 10 of the Viking VIPR182 user manual — BACKSIDE OF REMOTE SWITCH
Page 10 · click to enlarge
Page 10

This page has been left

blank intentionally.

BACKSIDE OF REMOTE SWITCH

TEMPLATE

Page 11 of the Viking VIPR182 user manual — INSTALL COOKTOP
Page 11 · click to enlarge
Page 11

INSTALL ELECTRICAL WIRING

Interior Blower Installation

Exterior Blower Installation

!

!

1. Mount a standard wiring box, with 3-pronged receptacle, inside the cabinet. Make sure the downdraft's power cord can easily reach it.
1. Mount a standard wiring box, with 3-pronged grounded receptacle, inside the kitchen cabinet. Make sure the downdraft's power cord can easily reach it.
2. Run appropriate power cable into cabinet and connect it to receptacle.
2. Run appropriate power cabinet into cabinet and connect it to electrical box and receptacle.
3. Plug the downdraft's power cord into the outlet. Make sure that the power cord is routed away from the heat generated by the cooktop.
3. Exterior blower may not exceed 6.0 Amp rating.
4. Run 2-wire plus ground power cable from the remote blower to wiring box on 10" round discharge plate.
5. Connect downdraft wiring to power cable from remote blower. Wire black to black, white to white, and green to green or bare wire.
6. Replace wiring box cover.
7. Plug the downdraft's power cord into outlet. Make sure that the power cord is routed away from the heat generated by the cooktop.

INSTALL COOKTOP

Viking VIPR182 — INSTALL COOKTOP diagram (page 11)
Fig. 17
1. Align the cooktop with the downdraft and fasten cooktop in place.

Rangetops and Designer Cooktops must be used with an "R" model downdraft (with remote control) - mounted into the countertop, at least 4" from the burners.

Page 12 of the Viking VIPR182 user manual — USE AND CARE
Page 12 · click to enlarge
Page 12

OPERATION

All Units UP / DOWN --- Raises and lowers

vent. Turns blower ON when vent is UP and OFF when vent is DOWN. Note: The UP/DOWN switch for models VIPR102SS, VIPR162SS, and VIPR182SS is on the right hand end of the top cover.

REMOTE CONTROL

FOR MODELS

VIPR102RSS VIPR162RSS VIPR182RSS

DELAY Allows blower to run for 10 min. after button is

pressed. Delay is activated by holding down any speed control button until the LED indicator fl ashes. Blower will run for 10 min. - then shut OFF. VENT WILL NOT LOWER. You must press UP / DOWN to lower vent. When DELAY is activated, the speed level light will blink.

1 2 3 4 FILTER RESET

UP/DOWN

BLOWER SPEEDS Blower operates at 4 different speed

levels. Press button ONCE to turn blower ON to desired speed. Press button AGAIN to turn blower OFF.

TOP COVER CONTROL FOR MODELS VIPR102SS VIPR162SS VIPR182SS

FILTER LIGHT Comes ON after 30 hours of opera-

tion to remind you to clean fi lters. Press button to reset.

USE AND CARE

Always turn the downdraft blower on before you begin cooking to es- tablish an air fl ow in the kitchen. Let the blower run for a few minutes to clean the air after you turn the cooktop off. This will keep the whole kitchen cleaner and brighter. The activating switch is pressed and the air vent rises.

Wash the 2 aluminum/stainless steel grease fi lters in a mild de- tergent solution or a dishwasher. Remove them from the air vent by grasping the tab at the top of each fi lter.

Servicing It may be necessary to remove the downdraft blower system from the cabinet in order to service components such as the blower motor or air vent mechanism.

Cleaning Use a mild detergent suitable for painted surfaces. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING POW- DERS. Vacuum blower to clean. Do not immerse blower in water.

Disconnect power to the cooktop and remove it fi rst. Reverse the steps under “MOUNT THE UNIT” to remove the downdraft from the cabinet.

Page 13 of the Viking VIPR182 user manual — 99044605C F20073C EN
Page 13 · click to enlarge
Page 13

PROFESSIONAL SERIES BUILT-IN REAR DOWNDRAFT WARRANTY

ONE YEAR FULL WARRANTY Built-in downdraft ventilators, all of their component parts and accessories, except as detailed below*, are warranted to be free from defective materials or workmanship in normal household use for a period of twelve (12) months from the date of original retail purchase. Viking Range, LLC, warrantor, agrees to repair or replace, at its option, any part which fails or is found to be defective during the warranty period. For the purpose of this warranty, normal household use shall not include use of this downdraft ventilator with a cooking unit that has a grill. The warranty does not cover any additional ventilation products not provided by Viking Range, LLC used in conjunction with downdrafts or ventilator kits. This includes, but is not limited to, such devices as booster fans or in-line blowers. Any malfunction caused to ventilation products as a direct result of the use of such equipment is not covered under the warranty.

Painted and decorative items are warranted to free from defective materials or workmanship for a period of ninety (90) days from the date of original retail purchase. ANY DEFECTS MUST BE REPORTED TO THE SELLING DEALER WITHIN NINETY (90) DAYS FROM DATE OF ORIGINAL RETAIL PURCHASE.

FIVE YEAR LIMITED WARRANTY Any ventilator motor which fails due to defective materials or workmanship in normal household use during the second through the fi fth year from the date of original retail purchase will be repaired or replaced, free of charge for the part itself, with the owner paying all other costs, including labor.

This warranty extends to the original purchaser of the product warranted hereunder and to each transferee owner of the product during the term of the warranty.

This warranty shall apply to products purchased and located in the United States and Canada. Products must be purchased in the country where service is requested. Warranty labor shall be performed by an authorized Viking Range, LLC service agency or representative. Warranty shall not apply to damage resulting from abuse, accident, natural disaster, loss of electrical power to the product for any reason, alteration, outdoor use, improper installation, improper operation or repair or service to the product by anyone other than an authorized Viking Range, LLC service agency or representative. This warranty does not apply to commercial usage. Warrantor is not responsible for consequential or incidental damage whether arising out of breach of warranty, breach of contract, or otherwise. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

Owner shall be responsible for proper installation, providing normal care and maintenance, providing proof of purchase upon request, and making the appliance reasonably accessible for service. If the product or one of its component parts contains a defect or malfunction during the warranty period, after a reasonable number of attempts by the warrantor to remedy the defects or malfunctions, the owner is entitled to either a refund or replacement of the product or its component part or parts. Replacement of a component part includes its free installation. Warrantor’s liability on any claim of any kind, with respect to the goods or services covered hereunder, shall in no case exceed the price of the goods or service or part there of which gives rise to the claim.

WARRANTY SERVICE: Under the terms of this warranty, service must be performed by a factory authorized Viking Range, LLC service agent or representative. Service will be provided during normal business hours, and labor performed at overtime or premium rates shall not be covered by this warranty. To obtain warranty service, contact the dealer from whom the product was purchased, an authorized Viking Range, LLC service agent, or Viking Range, LLC. Provide model and serial number and date of original purchase. For the name of your nearest authorized Viking Range, LLC service agency, call the dealer from whom the product was purchased or Viking Range, LLC. IMPORTANT: Retain proof of original purchase to establish warranty period.

The return of the Owner Registration Card is not a condition of warranty coverage. You, however, should return the Owner Registration Card so that Viking Range, LLC can contact you should any question of safety arise which could affect you. Any implied warranties of merchantability and fi tness applicable to the above described ventilator motor are limited in duration to the period of coverage of the applicable express written limited warranties set forth above. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specifi c rights, and you may also have other rights which may vary from jurisdiction to jurisdiction.

VIKING RANGE, LLC

111 Front Street Greenwood, Mississippi 38930 USA

(662) 455-1200

Specifi cations subject to change without notice. For more product information, call 1-845-4641, or visit our

web site at http://www.vikingrange.com in the US or

brigade.ca in Canada.

99044605C F20073C EN

Ask about the Viking VIPR182

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Viking VIPR182

Be the first to ask — other owners or our team will answer.

Original document

Viking VIPR182 manual PDF

40 pages·1 MB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…