FOR USE WITH VIKING VCWH, VICH, DBCV, DICV, DCWH, DCWL, DCWN, DTWS AND DCIH RANGE HOODS. 30" TO 42" WIDE, 9" TO 18" HIGH.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer or your distributor. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnect- ing means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a promi- nent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire- rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Associa- tion (NFPA), and the American Society for Heat- ing, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION 1. For general ventilating use only. Do not use to ex- haust hazardous or explosive material and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, con- struction dust, etc. off power unit. 3. Please read specification label on product for further information and requirements. 4. Electrical circuit, including speed control, (if used), must be rated 6 AMPS minimum.
Blower Dimensions 28.25 x 24.75 x 7.17
HOMEOWNER: Use And Care Information On Page 4

PREPARE THE INSTALLATION LOCATION
WALL INSTALLATIONS
25"
10¾"
10¾"
20¾" 20¾"
REMOVE
SIDING REMOVE
8½" 8½"
SIDING 8½" 8½"
12 7 / 8 "
12 7 / 8 "
11" dia. hole
11" dia. hole
REMOVE SHINGLES
11" dia. hole
11" dia. hole
Pilot Pilot Hole Hole Pilot Hole
10 3 / 8 "
Pilot Pilot Hole Hole Pilot Hole
Wall Stud Wall Stud
28¼"
20½"
20½"
1¼" dia. hole
1¼" dia. hole
9 1 / 8 " 9 1 / 8 "
1¼" dia. hole
1¼" dia. hole
7¼" 7¼"
OUTSIDE - WALL VIEW OUTSIDE - WALL VIEW
OUTSIDE - ROOF VIEW OUTSIDE - ROOF VIEW
From inside the wall: 2. Drill a PILOT HOLE through the wall, 8½" from the inside edge of a WALL STUD.
From inside the attic space: 2. Drill a PILOT HOLE up through the roof, 8½" from the inside edge of a ROOF RAFTER.
From outside - on the roof: 3. Measure and mark the 20¾" x 20½" rectangle. Cut and remove only the shingles inside this rectangle. 4. Measure and mark the 11" DIAMETER HOLE and the 1¼" DIAMETER HOLE. Cut these holes all the way through the roof.
From outside - on the wall: 3. Measure and mark the 25" x 29½" rectangle. Cut and remove only the siding inside this rectangle. 4. Measure and mark the 11" DIAMETER HOLE and the 1¼" DIAMETER HOLE. Cut these holes all the way through the wall.
ALL INSTALLATIONS
6¾"

INSTALL THE VENTILATOR
WALL INSTALLATIONS
TO BLACK
WHITE
TO WHITE
GREEN
TO GREEN

USE AND CARE
Disconnect electrical power supply and lock out service panel before cleaning or servicing this unit.
CLEANING Remove cover and carefully vacuum ventilator and inside of housing. Be careful not to bend or otherwise damage ventilator wheel.
MOTOR LUBRICATION The motor is permanently lubricated. Do not oil or disassemble motor.

LINE IN 120 VAC 60 HZ 10 A MAX.