VIKING MODEL DEV900 EXTERIOR MOUNTED VENTILATOR

FOR USE WITH VIKING VCWH, VICH, DBCV, DICV, DCWH, DCWL, DCWN, DTWS AND DCIH RANGE HOODS. 30" TO 42" WIDE, 9" TO 18" HIGH.

READ AND SAVE THESE INSTRUCTIONS

WARNING

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer or your distributor. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnect- ing means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a promi- nent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire- rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Associa- tion (NFPA), and the American Society for Heat- ing, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall, or ceiling, do not damage electrical wiring or other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. To reduce risk of fire, use only metal ductwork. 8. This unit must be grounded.

CAUTION 1. For general ventilating use only. Do not use to ex- haust hazardous or explosive material and vapors. 2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, con- struction dust, etc. off power unit. 3. Please read specification label on product for further information and requirements. 4. Electrical circuit, including speed control, (if used), must be rated 6 AMPS minimum.

Blower Dimensions 28.25 x 24.75 x 7.17

SPECIFICATIONS

MODELVOLTSAMPSCFMDUCT SIZE DEV9001205.790010 " DIA.

PLAN THE INSTALLATION

ALL INSTALLATIONS

1. Locate the ventilator so the length of the duct run and number of elbows needed are kept to a minimum. 2. Where possible, ventilator should be centered between wall studs or roof rafters. 3. Avoid pipes, wires, or other ductwork that may be running through the wall.

INSTALLER: Leave This Manual With The Homeowner

HOMEOWNER: Use And Care Information On Page 4

Page 2 of the Viking DEV900 user manual — 24¾"
Page 2 · click to enlarge
Page 2

PREPARE THE INSTALLATION LOCATION

PREPARE THE INSTALLATION LOCATION

ROOF INSTALLATIONS

WALL INSTALLATIONS

1. Locate the ventilator on the rear slope of the roof. Place it in a location to minimize duct run. The location should be free of obstacles (T.V. leads, electrical lines, etc.). Bear in mind, if the ventilator top is level with the roof peak, it will not be seen from the street. Keep this approximate location in mind as you work from within the attic.
1. Choose a position on the outside wall. Make sure that no wall studs, pipes or wires run through the opening area.

24¾"

25"

10¾"

10¾"

20¾" 20¾"

REMOVE

SIDING REMOVE

8½" 8½"

SIDING 8½" 8½"

12 7 / 8 "

12 7 / 8 "

11" dia. hole

11" dia. hole

REMOVE SHINGLES

REMOVE SHINGLES

11" dia. hole

11" dia. hole

Pilot Pilot Hole Hole Pilot Hole

10 3 / 8 "

10 3 / 8 "

Pilot Pilot Hole Hole Pilot Hole

Wall Stud Wall Stud

29½"

28¼"

20½"

20½"

1¼" dia. hole

1¼" dia. hole

9 1 / 8 " 9 1 / 8 "

9 1 / 8 " 9 1 / 8 "

1¼" dia. hole

1¼" dia. hole

7¼" 7¼"

7¼" 7¼"

OUTSIDE - WALL VIEW OUTSIDE - WALL VIEW

OUTSIDE - ROOF VIEW OUTSIDE - ROOF VIEW

From inside the wall: 2. Drill a PILOT HOLE through the wall, 8½" from the inside edge of a WALL STUD.

From inside the attic space: 2. Drill a PILOT HOLE up through the roof, 8½" from the inside edge of a ROOF RAFTER.

From outside - on the roof: 3. Measure and mark the 20¾" x 20½" rectangle. Cut and remove only the shingles inside this rectangle. 4. Measure and mark the 11" DIAMETER HOLE and the 1¼" DIAMETER HOLE. Cut these holes all the way through the roof.

From outside - on the wall: 3. Measure and mark the 25" x 29½" rectangle. Cut and remove only the siding inside this rectangle. 4. Measure and mark the 11" DIAMETER HOLE and the 1¼" DIAMETER HOLE. Cut these holes all the way through the wall.

PREPARE THE VENTILATOR

2"

ALL INSTALLATIONS

6¾"

1. Unpack the ventilator assembly.

2"

2. Remove the cover and screws.

28¼"

3. Remove and discard cardboard from ventilator wheel.

24¾"

4. Remove the wiring box cover and screws.
5. For flat roof installations, build a curb that will mount the ventilator at a minimum pitch of 2/12. See Figure 2. Discharge end of the ventilator should be pointed away from prevailing winds.
5. Attach an appropriate U.L. approved cable connector in the hole at the rear of the wiring box.
Show 4 more labels / short text on this page
Wall Stud · Wall Stud · Roof Rafter · Roof Rafter
Page 3 of the Viking DEV900 user manual — 120 VAC LINE IN
Page 3 · click to enlarge
Page 3

INSTALL THE VENTILATOR

INSTALL THE VENTILATOR

ROOF INSTALLATIONS

WALL INSTALLATIONS

1. Remove roofing nails from the upper 2/3 of the shingles around the cutout area and carefully lift the shingles to allow the back flashing sheet on the ventilator housing to fit under them.
1. Place a large bead of caulk on the back side of the housing along the outer edge.
2. Center the ventilator ring in the 11" diameter hole, making sure that the 1-1/4" diameter electrical wiring hole aligns with the hole in the wiring box.
2. Center the ventilator ring in the 11" diameter hole, making sure that the 1-1/4" diameter electrical wiring hole aligns with the hole in the wiring box.
3. Attach ventilator to the wall with the six screws provided. All six holes in the back panel must be filled, or any moisture that may get inside the ventilator housing could leak into the house.
3. Attach the ventilator to the roof with the six screws provided. All six holes in the back panel must be filled, or any moisture that may get inside the ventilator housing could leak into the house.
4. Using a good grade of caulk, seal all around the mounting screw heads.
4. Using a good grade of roofing cement, seal all of the shingles around the housing and flashing sheet as well as the mounting screw heads.
5. Bring electrical wiring through the hole in the wiring box and secure it according to local codes.
5. Bring electrical wiring through the hole in the wiring box and secure it according to local codes.
6. Make the electrical connections with the proper connector for the type of wire being used. Connect white to white, black to black, and green or bare wire to green. See Figure 4.
7. Replace wiring box cover and screws. Do not pinch wiring under cover.

BLACK

TO BLACK

8. Check for free movement of the damper before installing housing cover and screws.
9. Top and side flanges of the back plate may be covered with trim strips. Do not block grille opening at bottom with trim. It will adversely affect performance of the ventilator.

120 VAC LINE IN

WHITE

TO WHITE

GREEN

TO GREEN

6. Make the electrical connections with the proper connector for the type of wiring being used. Connect white to white, black to black, and the green or bare wire to green. See Figure 4.
7. Replace wiring box cover and screws. Do not pinch wiring under the cover.
8. Check for free movement of the damper before installing housing cover and screws.
Page 4 of the Viking DEV900 user manual — 99043050E F20222
Page 4 · click to enlarge
Page 4

INSTALL THE ROUGH-IN PLATE

USE AND CARE

1. Run 10" round steel ductwork, from exterior ventilator to the installation location. For best performance, use the straightest possible duct run and the fewest number of elbows. Tape all joints. 2. Run 120 VAC electrical power cable from service panel and from remote ventilator to installation location. 3. Remove wiring box cover. Remove knockouts from the wiring box. Feed 6" of power cable through openings and attach cables to wiring box with appropriate connectors.

Disconnect electrical power supply and lock out service panel before cleaning or servicing this unit.

CLEANING Remove cover and carefully vacuum ventilator and inside of housing. Be careful not to bend or otherwise damage ventilator wheel.

MOTOR LUBRICATION The motor is permanently lubricated. Do not oil or disassemble motor.

Viking DEV900 — INSTALL THE ROUGH-IN PLATE diagram (page 4)
Fig. 1

LINE IN 120 VAC 60 HZ 10 A MAX.

4. Wire black to black, white to white, and green or bare wire beneath green ground screw. Replace wiring box cover.
Viking DEV900 — INSTALL THE ROUGH-IN PLATE diagram (page 4)
Fig. 2
5. Connect ductwork to transition and tape joint. 6. Turn on power and check ventilator operation.

VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA

99043050E F20222

Ask about the Viking DEV900

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Viking DEV900

Be the first to ask — other owners or our team will answer.

Original document

Viking DEV900 manual PDF

8 pages·248 KB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…