Viking DEV1200

8 pages·232 KB·Ventilation Hood·PDF·ENDEITNLJA
Viking DEV1200
Table of Contents 32 sections WARNING · CAUTION · SPECIFICATIONS · INSTALLER: Leave This Manual With The Homeowner · … ShowHide
Page 1 of the Viking DEV1200 user manual — INSTALLER: Leave This Manual With The Homeowner
Page 1 · click to enlarge
Page 1
Viking DEV1200 — WARNING diagram (page 1)
Fig. 1

FOR USE WITH VIKING VCWH, VICH, DBCV, DICV, DCWH, DCWL, DCWN, DTWS AND DCIH RANGE HOODS. 30" TO 66" WIDE, 9" TO 18" HIGH.

WARNING

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manu- facturer. If you have questions, contact the manufac- turer or your distributor. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Soci- ety for Heating, Refrigeration and Air Conditioning Engi- neers (ASHRAE), and the local code authorities.

5. When cutting or drilling into wall, or ceiling, do not damage electrical wiring or other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. To reduce risk of fire, use only metal ductwork. 8. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
3. Please read specification label on product for further information and requirements. 4. Electrical circuit, including speed control, (if used), must be rated 6 AMPS minimum.

Blower Dimensions 22 x 30.828 x 12.724

SPECIFICATIONS

Viking DEV1200 — SPECIFICATIONS diagram (page 1)
Fig. 2
MODELVOLTSAMPSCFMDUCT SIZE DEV12001203.0120010" DIA.
1. Locate the ventilator so the length of the duct run and number of elbows needed are kept to a minimum. 2. Where possible, ventilator should be centered between wall studs or roof rafters. 3. Avoid pipes, wires, or other ductwork that may be running through the wall.

INSTALLER: Leave This Manual With The Homeowner

HOMEOWNER: Use And Care Information On Page 4

Page 2 of the Viking DEV1200 user manual — 29-1/2" 2"
Page 2 · click to enlarge
Page 2

PREPARE THE INSTALLATION LOCATION

PREPARE THE INSTALLATION LOCATION

ROOF INSTALLATIONS

WALL INSTALLATIONS

1. Locate the ventilator on the rear slope of the roof. Place it in a location to minimize duct run. The location should be free of obstacles (T.V. leads, electrical lines, etc.). If the ventilator top is level with the roof peak, it will not be seen from the street. Keep this approximate location in mind as you work from within the attic.
1. Choose a position on the outside wall. Make sure that no wall studs, pipes or wires run through the opening area.
2. From inside, mark and drill a guide hole centered between wall studs .
2. Mark and drill a guide hole centered between roof rafters .

Ø

17"

Ø

Ø

15"

1¼" dia. hole 1¼" dia. hole

Ø

Guide hole (centered between studs)

Guide hole (centered between studs)

1¼" dia. hole 1¼" dia. hole

3 "

14 11 / 16 "

REMOVE SHINGLES REMOVE SHINGLES

12 11 / 16 "

12 11 / 16 "

20½"

20½"

29½" 29½"

11" dia. hole

11" dia. hole

11" dia. hole

11" dia. hole

REMOVE

SIDING REMOVE

SIDING

9 11 / 16 "

9 13 / 16 "

18"

18"

1113/16" 1113/16"

22"

22"

3. From the outside, use the guide hole as a starting point to lay out the installation: A. Use a T-square to measure 9 13 / 16 " to the left of the
3. From the outside, use the guide hole as a starting point to lay out the installation: A. Use a T-square to measure 11 13 / 16 " to the left of the

guide hole, then up 1211/16" to locate the top-left corner of the layout. B. Starting from the top-left corner, mark the rectan-

guide hole, then up 1411/16" to locate the top-left corner of the layout. B. Starting from the top-left corner, mark the rectan-

gular cutout (18" W x 20½" H) and remove only the shingles in this area. C. Mark an 11" diameter hole centered on the guide

gular cutout (22" W x 29½" H) and remove only the siding in this area. C. Mark an 11" diameter hole centered on the guide

hole. Cut this hole through the roof board(s). D. Mark and cut a 1¼" diameter hole through the roof

board(s) where shown.

hole. Cut this hole through the roof board(s). D. Mark and cut a 1¼" diameter hole through the roof

board(s) where shown.

29-1/2" 2"

7"

22" 2"

4. For flat roof installations, build a curb that will mount the ventilator at a minimum pitch of 2/12. Discharge end of the ventilator should be pointed away from prevailing winds.
Show 12 more labels / short text on this page
17" · 1" · Roof Rafter · Roof Rafter · Roof Rafter · Roof Rafter · Wall Stud · Guide hole · Guide hole · Wall Stud · (centered between rafters) · (centered between rafters)
Page 3 of the Viking DEV1200 user manual — ROOF INSTALLATIONS
Page 3 · click to enlarge
Page 3

INSTALL THE VENTILATOR

INSTALL THE VENTILATOR

ROOF INSTALLATIONS

WALL INSTALLATIONS

1. Remove the cover and screws.
1. Place a large bead of caulk on the back side of the housing all along the outer edges.
2. Attach an appropriate U.L. approved cable connector in the hole at the rear of the wiring box.
2. Center the ventilator ring in the 11" diameter hole, making sure that the 1¼" diameter electrical wiring hole aligns with the hole in the wiring box.
3. Remove roofing nails from shingles around the TOP and SIDES of the cutout area only.Carefully lift the shingles to allow the back flashing sheet on the ventilator housing to fit under them.
3. Attach ventilator to the wall with the six (6) screws provided. It is recommended that the screws be located inside the ventilator housing. Drill pilot holes if necessary.
4. Center the ventilator ring in the 11" diameter hole, making sure that the 1¼" diameter electrical wiring hole aligns with the hole in the wiring box.
4. Using a good grade of caulk, seal all around the mounting screw heads.
5. Attach the ventilator to the roof with six (6) screws provided. It is recommended that the screws be located inside the ventilator housing. Drill pilot holes if necessary.
5. Bring electrical wiring through the hole in the wiring box and secure it according to local codes.
6. Using a good grade of roofing cement, seal all of the shingles around the housing and flashing sheet as well as the mounting screw heads.
Viking DEV1200 — ROOF INSTALLATIONS diagram (page 3)
Fig. 3
7. Bring electrical wiring through the hole in the wiring box and secure it according to local codes.
6. Make the electrical connections with the proper connector for the type of wire being used. Connect black to black, white to blue, and green or bare wire to grounding screw.
7. Replace cover and screws. Do not pinch wiring under cover.
8. Make the electrical connections with the proper connector for the type of wiring being used. Connect black to black, white to blue, and the green or bare wire to grounding screw.
8. Make sure damper opens and closes freely.
9. Top and side flanges of the back plate may be covered with trim strips. Do not block grille opening at bottom with trim. It will adversely affect performance of the ventilator.
9. Replace cover and screws. Do not pinch wiring under the cover.
10. Make sure damper opens and closes freely.
Page 4 of the Viking DEV1200 user manual — 99043051D F20221
Page 4 · click to enlarge
Page 4

INSTALL THE ROUGH-IN PLATE USE AND CARE

1. Run 10" round steel ductwork, from exterior ventilator to the installation location. For best performance, use the straightest possible duct run and the fewest number of elbows. Tape all joints.

Disconnect electrical power supply and lock out service panel before cleaning or servicing this unit.

CLEANING

2. Run 120 VAC electrical power cable from service panel and from remote ventilator to installation location.

Remove cover and carefully vacuum ventilator and inside of housing. Be careful not to bend or otherwise damage ventilator wheel.

3. Remove wiring box cover. Remove knockouts from the wiring box. Feed 6" of power cable through openings and attach cables to wiring box with appropriate connectors.

MOTOR LUBRICATION

Viking DEV1200 — MOTOR LUBRICATION diagram (page 4)
Fig. 4

The motor is permanently lubricated. Do not oil or disassemble motor.

M GROUND LINE IN 120 VAC 60 HZ 10 A MAX.

4. Wire black to black, white to white, and green or bare wire beneath green ground screw. Replace wiring box cover.
Viking DEV1200 — MOTOR LUBRICATION diagram (page 4)
Fig. 5
5. Connect ductwork to transition and tape joint.
6. Turn on power and check ventilator operation.

VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA

99043051D F20221

Ask about the Viking DEV1200

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Viking DEV1200

Be the first to ask — other owners or our team will answer.

Original document

Viking DEV1200 manual PDF

8 pages·232 KB·Ventilation Hood·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…