GAS/ELECTRIC RANGE for residential use only THIS RANGE IS FOR RESIDENTIAL USE ONL Y FOR INST ALLER ONL Y Some models are supplied with a protective lm on steel and aluminium parts. This lm must be removed before installing/using the appliance. Models: VEFSGE 304 SC.
2 WARNING ! T o reduce the risk of tipping the appliance, the appliance must be secured by properly installed anti-tip device packed with the appliance.
3 This appliance isdesigned and manufactured solely forthe cooking of domestic (household) food and in not suitable for any none domestic application and therefore should not be used in a com- mercialenvironmement.
4 INST ALLA TION INSTRUCTIONS W ARNING! THIS APPLIANCE MUST BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a quali - ed installer , service agent, or the gas supplier .
5 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absen- ce of local codes, with the National Fuel Gas Code , ANSI Z223.1/NFP A 54 - Latest Edition, CAN/CGA-B149.
6 PROXIMITY T O SIDE CABINETS 1. This range may be installed directly adjacent to existing 36” (914 mm) highbasecabinets. Rangedimensions: • width:29”7/8(759mm) • depth:24”13/64(614.
7 A A B ASSEMBLING THE BACKGUARD It is mandatory to install the backguard. Assemblethebackguardasshowningure1.3: • Screwthe2screws“ A ”interposingthespacers. • Screwthecentralscrew“ B ”.
8 B G E D C F A A B C E D F G A A PROXIMITY T O SIDE CABINETS ST ANDARD INST ALLA TION Fig. 1.4b Fig. 1.4a OVEN VENT Ref. inch mm A 0” 0 B 36” 914 C 1 1”13/16 300 D 30”minimum 762mini.
9 PROXIMITY T O SIDE CABINETS ISLAND INST ALLA TION A A B G E D F C H A A B G E D F C H Fig. 1.5b Fig. 1.5a OVEN VENT Ref. inch mm A 0” 0 B 36” 914 C 1 1”13/16 300 D 30”minimum 762min.
10 1 LEVELLING THE RANGE Therange isequipped with4 LEVELLINGFEETand maybe levelledby screwingor unscrewingthefeet(gs.1.6-1.7). Itisimportanttoobservethedirectionsofgures1.
11 1 INST ALLING THE COOKTOP FRONT GUARD T o increasethe clearance between the front edgeof the cooktop and the burnersit is possible to install thecooktop front guard supplied withtheappliance.
12 gas connection 2 2. Pressure Regulator: a. Allheavyduty ,commercialtypecookingequipmentmusthaveapressureregulator onthe incomingservice linefor safeand efcientoperation, sinceservice pressure mayuctuatewithlocaldemand.
13 2 LOCK Arrow PRESSURE REGULA TOR INST ALLA TION STEP 1 Mountthe1/2”NPT (conical)maleconnectortothepressureregulatorand tightenbyusingawrench. Donotovertightentheconnector . Overtighteningmaycrackregulator .
14 2 Fig. 2.4 GAS CONNECTION SPEFICICA TION Range manifold Manifold male pipe tting 1/2”Gcylindrical (ISO228-1)male 1/2”Gcylindrical (ISO228-1)female Gasket Extension pi.
15 2 b. Any conversion required must beperformed by yourdealer or aqualied licen- sed technician or gas service company . Please providethe service person with this manual before work is started on the range.
16 2 Pressur e regulator 1 2 NATURAL GAS REGULATION LP/PROPANE REGULATION A REGULA TOR COVER CONVERSION TO LP/PROP ANE GAS (OR CONVERSION BACK TO THE ORIGINAL GAS - NA TURAL GAS) Everyrangeisprovidedwithasetofinjectorsforthevarioustypesofgas.
17 2 OPERA TIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS • Removethepansupports,theburnercapsandtheamespreaders.
18 Fig. 2.10 R 1 Regulationscrew(Semirapidburner) R 2 Regulationscrew(Innercrownofdualburner) R 3 Regulationscrew(Outercrownofdualburner) R 1 R.
19 electrical connection 3 W ARNING TO A VOID ELECTRICAL SHOCK HA- ZARD, BEFORE INST ALLING THE APPLIANCE, SWITCH POWER OFF A T THE SERVICE P ANEL AND LOCK THE P ANEL TO PREVENT THE PO- WER FROM BEING SWITCHED ON ACCIDENT ALL Y .
20 3 3-Wire Power Cord Installation (SeeFigure3.2) 1. Remove the T erminal Block Access Plate on the back of the rangebyunscrewingthe4xing Screws (Figure3.1). 2. Check the correct positioning of the Power Cord Bracket as pergure3.
21 3 3-Wire Conduit Installation (SeeFigure3.5) 1. Remove the T erminal Block Access Plate on the back of the rangebyunscrewingthe4xing Screws (Figure3.4). 2. Check the correct positioning of the Conduit Bracket as per gure3.
22 3 WIRING DIAGRAM ELECTRIC DIAGRAM KEY IC IGNITIONCOIL ISG IGNITIONSWITCHESGROUP OL OVENLAMP E61 RELA Y CE CIRCULARELEMENT GE BROIL ELEMENT TE TOP ELEMENT BE-INT BOTTOMELEMENT INT . BE-EXT BOTTOMELEMENT EXT .
23.
Themanufacturer cannot beheld responsiblefor possibleinaccuracies due toprin- tingortranscriptionerrorsinthepresentbooklet.
An important point after buying a device Verona VEFSGE 304 SC.. (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Verona VEFSGE 304 SC.. yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Verona VEFSGE 304 SC.. - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Verona VEFSGE 304 SC.. you will learn all the available features of the product, as well as information on its operation. The information that you get Verona VEFSGE 304 SC.. will certainly help you make a decision on the purchase.
If you already are a holder of Verona VEFSGE 304 SC.., but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Verona VEFSGE 304 SC...
However, one of the most important roles played by the user manual is to help in solving problems with Verona VEFSGE 304 SC... Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Verona VEFSGE 304 SC.. along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center