SAFETY INFORMATION
Please read this manual before installing and using appliance.
—Do not store or use gasoline or
any other appliance. —WHAT TO DO IF YOU SMELL GAS
Homeowner’s Installation
and Operating Manual
This is an unvented gas-fired heater. It uses air (Oxygen) from the room in which it is installed. Provisions for adequate combust0ion and ventilation air must be provided. Refer to Page 7.

E
S
G
N
CFM Specialty Home Products
E
R
T
F
E
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
20004555 9/05 Rev. 12



In order to ensure safe and effective installation, this unit must be installed only by a qualified agency, individual, firm, corporation or company that is experienced in the instal- lation, repair and servicing of this type of appliance and is familiar with the building codes and installation techniques appropriate in your area. Contact your hearth products dealer or local gas supplier for the name of a qualified ser- vice person. In the Commonwealth of Massachusetts, all gas fittings and installation of this heater shall only be done by a licensed gas fitter or licensed plumber. IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or ser- vice this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, elec- trical shock, and carbon monoxide poisoning. Failure to follow instructions may result in property damage, bodily injury or loss of life. This manual contains impor- tant user information. Keep this manual with the heater after installation is complete. FOR SAFE INSTALLATION AND OPERATION, PLEASE NOTE THE FOLLOWING:
MAY LEAD TO DEATH!
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have the heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
20004555


Fig. 1 Radiance Vent Free dimensions.
20004555


Combustible Materials
Maintain clearance, (empty space), between combus- tible materials and the heater as specified below.

A: To Side Wall / Trim* 4” (101.6mm) B: To Rear Wall 4” (101.6mm)
Fig. 3 Minimum mantel clearance.
The Radiance Unvented heater must be installed on rigid flooring. If the appliance is installed on any com- bustible surface other than wood flooring, such as carpet or tile, a metal or wood panel must be installed to extend the full length and width of the unit. There are no other hearth or floor protection requirements.
A: Maximum Alcove Depth 24” (609mm) B: To Side Wall 4” (101mm) C: To Rear Wall 4” (101mm) D: To Ceiling 60” (1524mm)

20004555

Input ratings are shown in BTU per hour and are certified without deration from elevations up to 4,500 feet (1,370m) above sea level.
Nuisance outages may occur at altitudes above 4,500 feet (1,370m) if dirt, dust, lint and/or cob- webs are allowed to accumulate on burner and/ or ODS pilot. Monthly inspection and cleaning is recommended for altitudes above 4,500 feet (1,370m)
Firebox weight / shipping 175 lbs.
For elevations above 4,500 feet (1,370m), instal- lations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
Certified to: ANSI Z21.11.2a-2001
Unvented Heaters
The installation of your Radiance stove must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do not derate this appliance for altitude up to 4,500 feet (1,370m). Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 11.0” w.c. for LP Gas.
Neither natural gas nor propane gas give off an odor when burned. The nature of a vent free combustion system, however, is such that odors may occasional- ly be produced during heater operation when impuri- ties exist in the immediate area. Cleaning solutions, paint, solvents, cigarette smoke, candles, adhesives, new carpet or textiles, etc., all can create fumes. These fumes may mix with combustion air and can create odor. Such odors will disappear over time, however the condition can be alleviated by opening a window or otherwise providing additional ventilation to the area.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohib- ited by state or local codes. This appliance is to be used only with the type of gas specified on the rating plate which is at- tached to the rear panel. This appliance is not convertible for use with other gases.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
20004555

The Radiance RUVSOD, Model Nos. 3357, 3358, 3370 thru 3379, is an unvented gas heating appliance tested and listed to the ANSI standard Z21.11.2-2000. This appliance is specifically configured to burn either Natural Gas or Propane fuel, as indicated on the metal rating plate attached to the rear shroud. The Radiance RUVSOD is not fuel convertible.
First, determine which classification defines the intend- ed space.
You must provide additional fresh air if the space falls into this classification. Unusually Tight Construction is defined as construction wherein: a. walls and ceilings exposed to the outside atmo- sphere have a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed and b. weather stripping has been added on openable win- dows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide supplemental fresh air for the appliance from outside the home as detailed on page 7, B. If your home does not meet the above criteria, follow the procedure below.
The RUVSOD is shipped fully assembled with the ex- ception of the log set. The log set is assembled during installation.
The RUVSOD is equipped with a Honeywell control valve that allows thermostatic control, on/off switch or a remote switch (not supplied).
The RUVSOD model incorporates variable regulators that allow you to adjust burner heat output between HIGH, (35,000 BTU), and LOW, (26,000 BTU). See the Operation Section for details.
A push button Piezo ignitor is used to light the stand- ing pilot. The pilot incorporates an Oxygen Depletion System (ODS/pilot) which will shut off gas flow to the burner in the event that sufficient fresh air becomes unavailable for continued safe operation.
and Ventilation
Determine if You Have a Confined
or Unconfined Space
WARNING
Use the following formula to determine if you have a confined or unconfined space. Space is defined as the room in which you will install the heater plus any adjoining rooms with doorless pas- sageways or ventilation grilles between the rooms. The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour, (4.8 m3 per kw), of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour, (4.8 m3 per kw), of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are consid- ered a part of the unconfined space. 1. Determine the volume of space, (length x width x height). Include adjoining rooms connected by doorless passageways or ventilating grilles. Example: A room that is 18’ x 12’ x 8’ has a volume of 1728 cubic feet, ( length x width x height). An adjoining open kitchen that is 10’ x 12’ x 8’ has a volume of 960 cubic feet. An adjoining open dining room is 12’ x 12’ x 8’ with a volume of 1152 cubic feet. The total space volume is 3840 cubic feet. (1728 + 960 + 1152).
This heater must have fresh air for proper opera- tion. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Modern construction standards have resulted in homes that are highly energy-efficient and that allow little heat loss. Your home needs to breathe, however, and all fuel-burning appliances within it require fresh air in order to function properly and safely. Exhaust fans, clothes dryers, fireplaces, and other fuel burning appli- ances all use the air inside the building. If the available fresh air is insufficient to meet the demands of these appliances, problems can result. The Radiance Unvented heater has specific fresh air requirements. You must determine that these fresh air requirements will be met within the space where the appliance will be installed. The following informa- tion will help you insure that adequate fresh air is avail- able for the heater to function properly.
Any space within a home can be classified in the follow- ing categories:
20004555

2. Divide the volume of space by 50 cubic feet. The result is the maximum BTU/Hr that the space can sup- port. Example: 3840 divided by 50 = 76.8 or 76,800 BTU/Hr. 3. Add the BTU/Hr ratings of all fuel-burning appliances installed in the same space, including the following: Gas Water Heater Gas Furnace Gas Fireplace Logs Unvented Gas Heater Vented Gas Heater* Other Gas Appliances* * Do not include Direct Vent appliances as these utilize outside air for combustion and vent to the outdoors. Example: Gas Range 55,000 BTU/Hr Unvented Heater +33,000 BTU/Hr Total 88,000 BTU/Hr 4. Compare the maximum BTU/Hr rating the space can support with the total BTU/Hr used by the appliances. Example: 76,800 BTU/Hr - max. the space can support 88,000 BTU/Hr - total used by appliances In this example, the maximum BTU/Hr that the space can support is less than the total used by the appli- ances, the space is considered to be Confined space. Additional air must be provided to meet the require- ments of the Unvented heater. A confined space may be ventilated in two ways: A) Open up or provide at least two ventilating grilles to an adjoining unconfined space. Use any of the options illustrated in Figure 4.
Each of the two grilles must provide an opening of at least 50 square inches, with all opening dimensions being at least 3”. One grille must be located within 12” of the ceiling; the other within 12” of the floor. (If the total exceeds 100,000 BTU/Hr, additional grilles will be required.) B) Vent the room directly to the outdoors. (Provide one square inch of opening for each 4,000 BTU/hr. If the total BTU/Hr used by the appliances is less than the maximum BTU/Hr the space is able to support, the room meets the Unconfined space criteria and no further ventilation is required. For further information on ventilation guidelines and sizing specifications follow the National Fuel Gas Code NFPA 54/ANSI Z223.1 Section 5.3.

This heater shall not be installed in a confined space unless provisions are made for adequate combustion and ventilation air.
If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992 Section 5.3.

20004555


Read these instructions thoroughly before starting the assembly. Follow procedures in the order given. Inspect the stove for damage before starting the assembly. Do not install this stove if any damage is evident. Contact your dealer immediately.
Remove the Front panel, the Screen panel, the Log Set and hardware bag from the firebox before positioning the stove. 1. Remove the accessory package from the top of the stove. The manual, hardware package, and lava rocks are packed on top of the firebox. Set these aside. 2. Remove the Front Plate. Grasp one side and the bottom, and lift the front plate as a unit (the control door attaches to the stove front). Swing the bottom edge out and away from the stove body, (Fig. 5) 3. Remove the screen frame. (Fig. 6) 4. Remove the Log Set. Lift out the package and any packing material from the burner tray and firebox. Unpack the log set and inspect each piece for dam- age. DO NOT INSTALL DAMAGED LOGS. Set the logs aside out of the way.
The Radiance is shipped on its back, mounted to a wooden pallet. It is fully assembled, although packing materials must be removed from the firebox and the Log Set installed. Connection to the gas supply must be performed only by a qualified gas technician who should also verify that adequate ventilation is available to support proper burner function.
Installation of optional accessories, such as the Fan, Glass/Catalyst, or thermostat, is most easily accom- plished before the gas supply connection is made.

Fig. 5 Remove the front plate.

20004555


It is easiest to install the optional fan kit #2767/FK26, before the stove is moved to its final location or con- nected to the gas line.
The fan consists of a blower assembly and a rheo- stat switch that are connected by a wire harness. The blower attaches to a bracket at the bottom of the rear shroud. The rheostat installs at the bottom of the stove on the left of the valve.
The fan kit includes a ‘snapstat’, a temperature-sens- ing switch which will be mounted to the blower duct just below the top plate of the stove. The snapstat automati- cally turns the fan on or off at approximately 109°F.
Fig. 7 Slide stove back just far enough to access rear leg holes. 2. Attach the rear legs using 3/8” hex head bolts and flat washer supplied. Tighten with a 9/16” wrench or socket.
The rheostat provides a range of fan speed settings from OFF (which overrides the snapstat function) to high.


Fig. 8 Carefully tip stove onto back legs. Leave pallet under stove to keep stove from falling fully forward.
Fig. 9 Loosen four phillips screws holding rear shroud as- sembly and remove. Remove four phillips screws holding rear shroud to inner duct assembly. Remove rear shroud.
Kit Contents · 20004555



Fig. 10 Attach the fan assembly to the fan bracket.
5. Connect snapstat leads. Disconnect the snapstat module from the leads inside the snapstat bracket. (Fig. 11) Bend open the snapstat bracket. Use needlenose pliers to remove the black plastic grommet from the bracket. Discard the bracket. Insert the grommet and wires into the large hole at the bottom right corner of the inner shroud. Feed the snapstat wire leads through the grommet into the stove interior. Connect the two wires to the two snapstat extension leads attached to the inner shroud.
Fig. 12 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metal screws.


Fig. 13 Install the snapstat and connect the extension wire terminals. View is with top removed, however, access is available through the rear when installing fan before gas line connection.
Fig. 11 Remove the snapstat and grommet from the bracket and insert the grommet into the inner shroud.
20004555

The switch assembly parts are found in the parts bag. 1. Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud. (Fig. 16) 2. Run wires down back of stove, under bottom of rear shroud to valve. 3. Attach wires to valve terminals. (Fig. 17)
Fig. 14 Attach rheostat to control panel. Valve may look dif- ferent.
Disconnect power before servicing.
BLK
BLK
SNAPSTAT
Fig. 16 Attach switch assembly to rear shroud.
WHT
WHT
GRN
ON/OFF RHEOSTAT
POWER
TP TH TPTH
Fig. 15 #2767 / FK26 Fan Wiring Diagram
The optional fan kit is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a prop- erly grounded three-prong outlet. Do not cut or remove the grounding prong from this plug.
ST228 Fig. 17 Attach switch wires to valve.
Use only a thermostat rated for 500 - 750 millivolts. Do not use low voltage (24V) thermostats.
Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation.
Thermostat Wire / Gauge Maximum Run 18 40 feet 20 25 feet 22 16 feet



Fig. 19 Be sure injector orifices remain at 90° to the base.


Fig. 18 Remove air shutter and discard.
20004555

This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below.

The Radiance Heater and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The Radiance Heater must be isolated from the gas supply piping system by closing its indi- vidual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig.
Fig. 22 Set glass frame in place and secure latches.
There must be a gas shutoff between the stove and the supply.
Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used.
In order to connect Natural Gas, use a fitting with 1/2” NPT on the valve side and 1/2” natural gas supply line with an input of 35,000 BTUs at a manifold pressure of 3.5” between minimum inlet supply of 5.5” w.c. and maximum of 14.0” w.c.
This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below. The Radiance Heater and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The Radiance Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig. There must be a gas shutoff between the stove and the supply. In order to connect Natural Gas, use a fitting with 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 35,000 BTUs at a manifold pressure of 3.5” and minimum inlet sup- ply for adjustment of 5.5” w.c. In order to connect Propane, use a fitting with 3/8” NPT nipple on the valve side and 1/2” propane gas supply line with an input of 35,000 BTUs at a mani- fold pressure of 11.0” and minimum inlet supply for adjustment of 11.0” w.c. Gas connection should be made in accordance with current National Fuel Gas Code, ANSI Z223.1. Since some municipalities have additional local codes, be sure to consult you local authority. Connect the gas supply and test for leaks. Use a 50/50 solution of liquid soap and water to test for leaks at gas fittings and joints. NEVER test with an open flame. Light the pilot according to the directions on page 16, before going to the next step.
In order to connect Propane, use a fitting with 1/2” NPT on the valve side and 1/2” propane gas sup- ply line with an input of 35,000 BTUs at a manifold pressure of 11.0” between a minimum inlet supply of 11.0” w.c. and maximum of 14.0” w.c.
1. Remove the logs from their packaging, and inspect each piece for damage. DO NOT INSTALL DAM- AGED LOGS. 2. Install the rear left log by placing it on the sheet metal shelf at the back of the firebox. (Fig. 23) The log should touch the back wall of the firebox. Slide the log to the left until the left side lines up with the left bracket. (Fig. 23) When the log is in place the left front corner of the log should rest on the decora- tive grate. 3. Install the rear right log by placing it on the sheet metal shelf at the back toward the right. Make sure the right side of the log lines up with the right bracket. (Fig. 23) NOTE: When the right and left rear logs are in place, they should touch the back of the firebox and each other. 4. Install the right log by engaging hole on the bottom with pin on the right rear log. (Fig. 23) Set the bottom of the log on the bracket and bring forward to come in contact with decorative grate on right.
20004555


1. Replace the screen frame by sliding the hooks over the top front edge of the firebox and resting the bot- tom on the support brackets. If the catalyst has been installed, place the glass front on the stove by rest- ing the bottom edge of the frame on support brack- ets below the front opening of the firebox. Swing the top edge of the assembly toward the firebox, and center it. Fasten it by closing the latches over the top left and right edges of the frame. 2. Replace the stove front by grasping it by the left and right edges. Lift it so that tabs on the back side of the top corners engage notches at the top forward corners of the stove sides. Then gently swing the bottom of the front panel to a vertical position, and lower it till prongs on its bottom left and right corners engage with notches cast into the tops of the forward legs. (Fig. 26) Test that the front is installed securely by grasping two of panel’s vertical bars, and pulling the panel toward yourself. When the panel is in place properly you should not be able to pull the bottom of the front toward yourself without also lifting it. 3. Attach the wooden handle to the control door using the #8-32 x 2” screw from the parts bag. (Fig. 27) 4. Set the screen and the cast-iron grate into the re- cess in the stove top. This completes the installation and assembly of the Radiance RUVSOD.
Fig. 23 Install the left and right rear logs and the right log.


Fig. 24 Completed log installation.

Fig. 26 Replace the front panel.

Lava rock may be placed in this area Decorative Grate
Fig. 25 Lava rock placement.
Fig. 27 Attach the handle to the control door.
20004555

The Radiance is shipped with the operable door front plate. The stove may be operated with the doors either open or closed. To open the front doors, insert the handle provided into the door latch stub and turn it to the right and up. (Fig. 28) When not in use, the handle may be stored in the handle holder on the right side of the rear shroud. (Fig. 29)
Fig. 30 Pilot assembly location.
HI
to decrease flame height
to increase flame height
Fig. 28 To open the front doors, turn handle counterclockwise.
Fig. 31 Flame adjustment knob for Honeywell valve.
It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the illustration below. (Fig. 32, 33) If the flame patterns ap- pear abnormal, contact a qualified service provider for service and adjustment.
ST656 Fig. 29 When not in use, store handle in the handle holder.
Read these instructions carefully and familiarize yourself with the burner controls shown on Page 17. Locate the pilot assembly, Figure 30. Follow the lighting instructions on Page 16 exactly.
During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within the first eight to ten hours, however, you can open a window to provide fresh air to alleviate the condition.
Fig. 32 Correct pilot flame appearance. OP pilot.
Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figure 32 and Figure 33. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the heater until the pilot flame is correct.
For units equipped with HI/LO valves, the flame adjust- ment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas valve. (Fig. 31)
Fig. 33 Correct burner flame pattern.

may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit manu-
ally. When lighting the pilot follow these instruc- tions exactly. B. BEFORE LIGHTING smell all around the heater
control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion. D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.
P
O
T
PILOT
F
F P
F
ON
ON
O
F
O
F
F
O
Euro SIT SIT NOVA Honeywell

Follow these procedures in the order presented.
TURN OFF HEATER AND ALLOW TO COOL COMPLETELY BEFORE SERVICING.
No spark at pilot when Ignitor is operated.
The Ignitor Electrode sparks, but Pilot does not light.

Fig. 34 Honeywell valve assembly.
20004555

Troubleshooting cont’d.
Pilot lights but flame goes out when Control Knob is released.

Pilot flame is weak - does not touch Thermocouple.
Correct LP Pilot Flame. Correct NG Pilot Flame.
Pilot lights but Main Burner does not.
Main Burner shuts off and Pilot flame goes out while in operation.
20004555

The following procedures will help ensure that your heater continues to perform safely and efficiently.
Cleanliness is critical to correct operation of the heater. The log set, burner, valve controls and air circulation areas must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean whenever accumulation is evi- dent. Follow the simple procedure outlined below.
Frequent cleaning may be necessary in living environ- ments subject to excessive carpet lint or pet hair. For example, if you live with a dog that sheds continuously, you will need to inspect the burner area frequently and clean it as often as the accumulation requires. In ex- treme conditions, it may be necessary to clean the burner and log set monthly or bi-weekly.
Fig. 35 Remove the screen or glass panel.
If so equipped, do not operate this appliance with the glass panel cracked, broken, or removed. Replace damaged glass only with CFM Specialty Home Prod- ucts ceramic glass panel Part No. 1601290. Follow the Cleaning Procedure instructions regarding parts removal.
This appliance should be inspected and thoroughly cleaned annually by a qualified gas technician.
An occasional dusting with a dry rag will help keep the painted surfaces looking new. Use high-temperature stove paints, available through your local dealer, to touch-up areas as needed. Clean areas to be painted with a wire brush and be sure to cover the log set, burner and valve assembly. Apply the paint sparingly; two light coats of paint will give better results than a single heavy coat.
Porcelain enamel surfaces should be cleaned with a soft, damp cloth. Do not use abrasive cleaning agents. If necessary, use only a cleaning agent formulated spe- cifically for use on porcelain enamel surfaces.
Use a soft-bristled brush vacuum cleaner attach- ment to remove dust or debris from the log set, pilot and burner. Use care as the log set is fragile.
Turn the burner Pilot OFF before applying paint. NEVER paint pilot or around pilot area.
Dust and debris accumulation can result in poor performance. Inspect the Valve compartment, burner parts and log set frequently and Clean these parts monthly or as often as accumula- tion warrants.
Screen Hooks · Glass Latch · 20004555


The combustor should be cleaned annually to ensure optimal performance. Follow the procedure below.
Fig. 36 Remove the front plate and top grille/screen.

Fig. 37 Remove the catalytic combustor module.
20004555


CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Radiance Vent Free Gas Heater (RUVSOD) Models 3357, 3358, 3370 thru 3379
Ref. Description RUVSOD 1. Gas Logset - RUVSOD 20004561 1a. Right Rear Log RUVSOD 20004562 1b. Left Rear Log RUVSOD 20004563 1c. Right Log RUVSOD 20004564 2. Manifold Assembly 20003739 3. Lava Rocks Burner 57897 4. Screen, RUVSOD 20004554 5. Frame, Glass - RDV40 1409112 6. Gasket, Glass Med, Knit - RDV40 1203702 7. Trim ON/OFF Switch 53606

20004555

Radiance Vent Free Gas Heater (RUVSOD) Models 3357, 3358, 3370 thru 3379 (continued)
Ref. Description RUVSOD 8. Handle Package, Ceramic w/Screw 0004342 9. Damper Steel Handle/Screw 5004265 10a. Valve NG Honeywell - VS84212003 10000235 10b. Valve LP Honeywell - VS84212011 10000242 11a. Oxygenerator, NG OP #8204 55464 11b. Oxygenerator, LP OP #8404 55465 12a. Burner Housing Assy. - RUVSODRN 20004492 12b. Burner Housing Assy. - RUVSODRP 20004552 13. Grate Decorative Burner 20003536 14. Back Log Support Bracket RUVSOD 20004553 15. Ignitor Piezo - Honeywell #396079 20000062 16. Front II, RDVOD Refer to Enamel Parts Chart Page 23 17. Door Left, RDVOD Refer to Enamel Parts Chart Page 23 18. Door Right, RDVOD Refer to Enamel Parts Chart Page 23 19. Door, RDVOD Refer to Enamel Parts Chart Page 23 20. Control Door Handle Assy. 10004442 21. Gasket, Base Pan/Firebox - RDV 20004286 22. Bracket, Log Right 20005259 23. Bracket, Log Left 20004708 24a. Orifice Hood #57 (0.043”) - Front - LP 20004587 24b. Orifice Hood #52 (.0635”) - Front - NG 30000331 24c. Orifice Hood #54 (.055”) - Rear - LP 20000130 24d. Orifice Hood #40 (.098”) - Rear - NG 20004263 25. Glass, GFP Firebox (Comes with RGDCFK) 1601290 26. Catalyst, RUV (not shown) (Comes with RGDCFK) 30000506 27. Left End Refer to Enamel Parts Chart Page 23 28. Right End Refer to Enamel Parts Chart Page 23 29. Leg Refer to Enamel Parts Chart Page 23 30. Top Refer to Enamel Parts Chart Page 23 31. Glass Frame Assembly (glass, gasket, frame) 5003075
Shell Enamel Part Numbers - Radiance Vent Free Gas Heater Model Color Top Left Right Front Left Right Control Leg Number End End Door Door Door (4) 3370, 3375 Classic 1301186 30001751 30001752 30001376 30001378 30001377 30001413 30001753 3371, 3376 Red 2321186 30001771 30001770 30001416 30001418 30001417 30001419 30001772 3372, 3377 Sand 1321186 30001774 30001773 30001420 30001422 30001421 30001423 30001775 3373, 3378 Moonlight 2371186 30001777 30001776 30001424 30001426 30001425 30001427 30001778 3374, 3379 Green 2311186 30001780 30001779 30001428 30001430 30001429 30001431 30001781 3357, 3358 Suede Brown 30002557 30002512 30002511 30002514 30002516 30002515 30002517 30002518
20004555

Screen Kit
An optional screen, R40SK, is avaialble for use with the operable doors to allow the doors to be left in the open position.
The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture. A rheostat provides for variable fan speeds.
Warming shelves add versatility to your stove; they can be used to keep foods warm at mealtime.
115 Volt / 60Hz / .75 Amps
1560 Classic Black 1562 Sand 1565 Red 1566 Green 1567 Moonlight Blue 1568 Suede Brown
The fan itself does not require regular maintenance, however, periodic cleaning of the fan and the surround- ing area is required.
The shelf installation is done in three stages. First you attach the shelf loosely to the stove, leaving the screws loose enough to allow final adjustments. Then, you po- sition the shelf and adjust the brackets so the shelf fits correctly. Finally, you tighten the screws.
Refer to Page 10 for installation instructions.
The remote control allows you to turn the heater on or off from anywhere in the room. Refer to Page 40 for wiring diagrams.
Refer to the instructions included with each warming shelf for complete installation procedures.
MRC1 ON/OFF MRC2 ON/OFF and Temperature MRC3 ON/OFF and Temperature control with a digital display and a programmable 24 hour clock IMT Wall mounted thermostat control
The Glass & Catalyst, RGODCFK, may be added to the stove to enhance stove performance. Refer to Page 12 for installation instructions.

20004555

20004555

LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document
CAST IRON: All external and internal cast iron parts are warranted for a period of three years. Note: On porcelain enamel finished external parts and accessories The Company offers no Warranty on chipping of enamel surfaces. Inspect all product prior to accepting it for any damage to the enamel. The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off. Dye lot variations with replacement parts and/or accessories can occur and are not covered by warranty.
GLASS DOORS: Glass doors are covered for a period of one year. Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix and masonry cleaners may corrode the brass finish. The Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions.
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year.
as near-by trees, buildings, roof tops, hills, or mountains. b) Inadequate ventilation or negative air pressure caused by
mechanical systems such as furnaces, fans, clothes dryers, etc. • This warranty is void if: a) The fireplace has been operated in atmospheres contaminated by
ACCESSORIES: Unless otherwise noted all components and CFM Specialty Home Products company supplied accessories are covered for a period of one year.
chlorine, fluorine, or other damaging chemicals. b) The fireplace has been subjected to prolonged periods of dampness
or condensation c) Any damages to the fireplace, combustion chamber, heat exchanger
or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation. d) Any alteration, willful abuse, accident, or misuse of the product
has occurred.
20004555

Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.