

Operator's
Manual
Model No.
358.798380
Always Wear Eye Protection
12 AMP MOTOR . 165 MPH A_r Velocaty ELECTRIC BLOWER/VAC
I HOURS (CST) ) Mort. - Sat, 7 a.m. - 7 p.m. Sun. 10 a,m. - 7 p.m.
!_ ARNING READ THE OPERATOR'S MANUAL AND FOLLOW ALL WARNINGS AND SAFETY INSTRUCTIONS. FAILURE TO DO SO CAN RESULT IN
SERIOUS INJURY.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 USA
530--083224--09/29/94


,,
ii iiiiiiil,llll IH I IIIl,l,ll I II I II I IIII " II II , IMPORTANT WARNINGS & SAFETY INSTRUCTIONS
, ,,,,,,,, _
The warnings and safety instructions in this manual must befollowed to reduce the risk of fire, electric shock, or injury, and to provide reasonable safety and efficiency in using this unit. The operator is responsible for following the warnings and instructions in this manual and on the unit Read the entire Operator s Manual before assembhng and using the unit! Restrmt the use of this und to persons who read, understand, and follow the warnings and instructions in this manual and on the unit.
i LOOK FOR THIS SYMBOL TO POINT OUT IMPORTANT SAFETY PRECAUTIONS. IT MEANS -] f_l.,, ATTENTION... BECOME ALERT tH YOUR SAFETY IS INVOLVED. f


open'ing, damaging the unit, property, or causing seri_ ous injury to bystanders or operator. • Stop the motor and disconnect the power source
such as ladders, trees, steep slopes, rooftops, etc. Use extra care when cleaning on stairways. Keepfirm footing and balance at all times. • Never place objects inside the blower tubes; al- ways direct the blowing debris away from people, ani-
if you need assistance, contact your SEARS Service Center/Department or call the CUSTOMER ASSISTANCE HOTLINE at 1-800-235-5878.


CONGRATULATIONS on your purchase of a Sears Craftsman Electdc Blower/vac. It has been d(tsigned, engineered and manufactured to give you the best possible dependability and performance. Should you experience.any problems you,cannot.easily remedy, please contact your nearest Sears Service Center/Department. Sears has competent, well trained technicians and the proper tools to service or repair this unit. Please read and retain this manual. The instructions will enable you to assemble and maintain your unit properly. Always observe the "SAFETY RULES."
VOLTAGE: 320 Volts A:C.
AIR VOLUME 405 c.f.m.
WEIGHT 7 Pounds
SERIAL NUMBER:
MANUFACTURED UNDER THE FOLLOWING U.S. PATENT: 4,325,163.
THE MODEL AND SERIAL NUMBER WILL BE FOUND ON A DECAL ATTACHED TO THE PRODUCT.
YOU SHOULD RECORD BOTH SERIAL NUMBER AND DATE OF PURCHASE AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
Ifthis Craftsman Electric BtowerNac fails to perform properly due to a defect in material or workmanship withintwo (2) years from the date of purchase, Sears will repair or replace it, free of charge.
This warranty does not cover the nylon line.
WARRANTY SERVICE 1S AVAILABLE BY RETURNING THE CRAFTSMAN ELECTRIC BLOWER/VAC TO THE NEAREST SEARS SERVICE STORE IN THE UNITED STATES.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
SEARS, ROEBUCK AND CO., D/817WA, HOFFMAN ESTATES, IL 60179


J
Safety Rules 2 Product Specifications 4 Customer Responsibilities 4,12 Warranty 4 Accessories 5
Assembly 6 Operation 9 Storage 13 Trouble Shooting 13 Repair Parts Ordering/Service Back Cover
I I Hill IIIII I IIIIIII J IIIIII IIIIIIIIIII IIII IIIIIII I A O Accessories 5 Operation 9, 10, 11 Assembly 6, 7,8 Ordering Repair Parts Back Cover C S Customer Assistance Hotline Back Cover Safety Rules 2,3 Customer Responsibilities 4, 12 Specifications 4 H Stopping & Starting your Unit 10 Hardware Contents 6 K Storage 13 Know Your Electric Blowerivac 9 T M Trouble Shooting 13 Maintenance Schedule 12 W Model Number . 4 Warranty 4
These accessories and attachments were available when the unit was originally purchased. They are also available at most Sears retail outlets and service centers. Most Sears stores can order these items for you when you provide the model number of your unit.
Extension Cord Safety Goggles


IL II= I Ill II
III Jllllllll III IL I IIIIIIIIIIIIIIIII IIIIIIII I II UJJ
PARTS PACKED SEPARATELY IN CARTON NOT SHOWN ACTUAL SIZE
Blower Tube Lower Vacuum Tube Flare Nozzle
HOW TO ASSEMBLE YOUR UNIT AS A VACUUM VACUUM TUBES ASSEMBLY (Fig. 3,& 4)
MUST BE STOPPED AND THE IMPELLER BLADES NO LONGER TURNING TO AVOID SERIOUS INJURY FROM THE ROTATING BLADES.
The lower vaccum tube is cut at an angle. Make sure the
Locking Latcb.,.__
Inlet cove,:. _) _/_
Blower Tube ,. _ Blower Tube
Concentrator Nozzle _""_ Flare Nozzle


L]] n , ,,n III I,,I n lU l, ,I I II I ,_TTACHING coLLEcTION BAG (Fig. 5) • Slide the opening of the collection bag over the blower outlet. Pull the strap with Velcrotightlythroughthe buckle and secure the Velcro tabs. NOTE: Make sure the strap with Velcm is located between the motor housing and the collar on the blower outlet.
° Stop unit and disconnect from power soume.
o Remove the vacuum tubes and collection bag. • Secure the inlet cover making sure that thetatch is se- curely fastened and screw is reinstalled. ° Reinstall the blower tubes. Refer to "Blower Tube Assembly" section. EXTENSION CORD (Fig. 8, & 9) Use only a voltage supply as shown on the nameplate of the unit to power your unit.
The extension cord used to reach the power source must be:
Collection Ba, Collar on Blower Outlet
COLLECTION BAG (Fig. 6, & 7)
- In good condition. Cord insulation must be intact with
no cracks or deterioration, Plug connectors must be un- damaged. Secure extension cord to unit as follows: • Tie cord from unit to extension cord.
° Plug cord from unit into extension cord. To reduce the risk of electric shock, this unit has a polarized plug (one blade is wider than the other). This plug will fit ina polarized extension cord only one way, If the plug does not fit fully into the extension cord, reverse the cord.
If it still does not fit, make sure you have a polarized extension cord. if the extension cord does not fit into the outlet, reverse the cord. If it still does not fit into the outlet, contact a qualifiedelectrician to installthe proper outlet. Do not change the plugor socket of the unitor extension cord in any way.
RECOMMENDATIONS
VOLTS 25 FT. 50 FT. 100 FT. 150 FT.
120 16 16 14 12
*American Wire Gauge Figure 8
Shoulder strap on right shoulder Free flow of air. No kinks In collection bag


CHECK LIST ° Check all.fasteners. Make sure they are tight and there are no loose parts. • Make sure the blowertube isfirmly seated in the blower outlet.
° In blower mode, check to insure the nozzle is securely seated in the blower tube.
ii jilL //


KNOW YOUR ELECTRIC BLOWER (Fig. 10) READ THIS OPERATOR'S MANUAL AND SAFETY RULES BEFORE OPERATING "fOUR ELECTRIC BLOWER. Compare the illustrationswithyour unit to famUiadze yourself with the location of the various controls and adjustments. Save this manual for future reference.
TOP HANDLE /
COLLECTION BAG
SIDE HANDLE
INLET COVER LATCH /
AIR VENTS
U
FLAR E NOZZLE CONCENTRATOR NOZZLE
LOWER VACUUM TUBE
The SIDE HANDLE is used to hold the unit during Vacuum mode.
The ONIOFF SWITCH is used to turn on the unit.
The INLET COVER LATCH is used to open the inlet cover for attaching Upper Vacuum Tube. The TOP HANDLE is used to hold the unit during the Blower and Vacuum mode.
The FLARE NOZZLE is use to direct the flow of air into a larger area than the CONCENTRATOR NOZZLE. The CONCENTRATOR NOZZLE is use to direct the flow of air into a concentrated area.
i ii rl:
This unit is Double Insulated to help protect against electric shock. Double insulationconstruction consists of two separate "layers" of electrical insulation instead of grounding.
_ WARNING ALL ELECTRICAL REPAIRS TO THIS UNIT, INCLUDING HOUSING, SWlTCH, i MOTOR, ETC., MUST BE DIAGNOSED AND REPAIRED BY QUALIFIED SER-;; VICE PERSONNEL. REPLACEMENT PARTS FOR A DOUBLE INSULATED AP- PLIANCE MUST BE IDENTICAL TO THE J PARTS THEY REPLACE. A DOUBLE IN- SULATED APPLIANCE IS MARKED WITH THE WORDS "DOUBLE INSULA- TION" OR "DOUBLE INSULATED". THE SYMBOL (SQUARE WITHIN A SQUARE)
Tools and appliances build with a double insulation system are not intended to be grounded. No grounding means is provided on this unit, nor should a means of grounding be added to this unit. As a result, the extension cord used with your unit can be plugged into anystandard 120 volt electrical outlet.
Safety precautions must be observed when operating any electrical tool. The double insulation system only pro- vides added protection against in}ury resulting from an inter-
[] MAY ALSO BE MARKED ON THE AP- PLIANCE. FAILURE TO HAVE THE UNIT REPAIRED BY QUALIFIED SERVICE PERSONNEL CAN CAUSE THE DOUBLE INSULATIONS CONSTRUC- TION TO BECOME INEFFECTIVE AND RESULT IN SERIOUS INJURY.
nal electrical insulation failure.


O'PERATOR SAFETY' "
° Dress safely in long pants. Do notgo barefoot orwear short pants, sandals, jewelry, loose clothing, or clothing with Ioose!y hanging strops, ties, tassels, etc.; they can be caught in moving parts. Secure hair so it is above shoulder length. Use of rubber gloves is recommended. • Check the unit before each operation. Look for worn, loose, missing, ordamaged parts. Do not use the unitun- til it is in proper working order.
DO NOT ASSEMBEEOR'DISASSEMBLE THE VACUUM TUBES WHILE THE UNIT IS RUNNING, INSERTING OR REMOVING THE VACUUM= TUBES WHILE THE UNIT IS RUNNING CAN RESULTIN SERIOUS INJURY. ALWAYSSTOP THE UNIT AND DISCONNECT THE POWER SOURCE BEFORE UNCLOGGING THE UNIT OR PERFORMING ANY MAINTENANCE ON THE COLLECTION BAG.
° inspect area before operating unit. Remove all debris and objects suchas rocks, glass, wire, large sticks, etc. that can cause damage during operation.
DO NOT USE THE UNIT WITHOUT THE BLOWER TUBES PROPERLY ATTACHED TO AVOID FLYING DEBRIS AND/OR IMPELLER CONTACT WHICH CAN CAUSE SERIOUS INJURY.
ALWAYS WEAR EYE PROTECTION TO PREVENT ROCKS OR DEBRIS FROM BEING BLOWN OR RICOCHETING INTO THE EYES AND FACE WHICH CAN RESULT IN BLINDNESS OR SERIOUS INJURY.
proper air flow.
DO NOT USE THE UNIT AS A VACUUM WITHOUT THE VACUUM TUBES AND COLLECTION BAG PROPERLY ATTACHED TO AVOID FLYING DEBRIS AND/OR IMPELLER CONTACT WHICH CAN CAUSE SERIOUS INJURY. ALWAYS MAKE SURE THE COLLECTION BAG IS COMPLETELY ZIPPED BEFORE THE UNIT IS STARTED.
° Never place objects inside the blower tubes; always direct blowing debris away from people, animals, glass,
and solid objects such as trees, automobiles, walls, etc. The force of air can cause rocks, dirt, or sticks to be thrown or to dcochet which may hurt people or animals,
DO NOT ATTEMPT TO VACUUM WATER OR OTHER LIQUIDSTO AVOID ELECTROCUTION.
break glass, or cause other damage.
° When using your unit as a vacuum, always use collec- tion bag shoulder strap to avoid loss of control.
As a blower, the unit is designed to sweep debris, grass, straw, leaves, or small twigs. Never use for spreading or misting chemicals, fertilizers, or any other materials which may contain toxic substances. As a vacuum, the unit is designed to pickup dry material such as leaves, grass, small twigs, and bits of paper. Do not attempt to vacuum stones, gravel, metal, broken glass, or any other debris which may cause damage to the impeller. Do not attempt to vacuum
bag assembly is completely zipped.
snow, water, orany other liquids: vacuuming water or other liquidswill cause damage to the unit. Avoid situations that couldcatch the collectionbag on fire. Do notoperate near an open flame. Do not vacuum discarded matches, cigars, or cigarettes, or ash from fireplaces, barbecue pits, brush piles, etc.
POSITIONS
BLOWER VACUUM
instructionsin the manual before operating the unit.


USING YOUR UNIT AS A VACUUM (Fig. 12) Use your unit as a vacuum to pick up dry matedal such as leaves, grass, small twigs, and bits of paper.
° Carefully reach into the vacuum opening and clear out debris.
PREVENT ROCKS OR DEBRIS FROM i BEING BLOWN OR RICOCHETING INTO THE EYES AND FACE WHICH CAN RESULT IN BLINDNESS OR SERIOUS INJURY.
° You must properly empty and maintain the collection bag to avoid deterioration and obstruction of air flow.
USING YOUR UNIT AS A BLOWER (Fig. 11) Use your unit as a blower for sweeping debris or grass clippings from driveways, sidewalks, patios, etc.
° Wash the collection bag once a year. Remove the bag from the blower and turn the bag inside out. Wash the bag with a water hose. Allow the bag to hang and dry before you reuse the bag.
Use your unit as a blower for blowing grass clippings, straw, or leaves into piles, or removing debris from comers, around joints, and between bricks.
- Direct air flow by directing the nozzle down orto one side. Always work away from solid objects such as walks, large stones, automobiles, and fences.
DO NOT FORCE INTO PILE.
- Clean comers by starting in comers and moving outward to straight areas to prevent an accumulation of debris which could fly into face.
BACK AND FORTH.
Vacuum Operating Position


iiii illl i =l MAINTENANCE SCHEDULE
Fill in dates as you complete regular service.
Check for damaged or worn parts.
,,,,,,,,,,,, Clean unit and labels.
i ,,,,,,,, Check for loose fasteners and parts.
Wash collection bag.
,,,,,,,,,,
The warranty on this unit does not cover itoms that have
if an object is drawn into the unit through the air intake, do the following:
been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain unit as instructed in this manual.
Some adjustments will need to be made periodically to properly maintain your unit.
All adjustments in the "Service and Adjustments" section of this manual should be checked at lease once each season.
Follow the maintenance schedule in this manual,
Vacuum Air Intake Inlet Cover
Air Vents Figure 14
The collection bag must be properly emptied and maintained to avoid deterioration and obstruction of air flow which will reduce the performance of your unit.
or damaged in any way.
Release Locking


Immediately prepare your unit for storage at the end of the season. STORAGE INSTRUCTIONS
m.lllllll i liH i ,,,,,,,,,,,,,,,,,,,,,,,, Hill. ,,,,, .ll illl i i.H. i ,,.,,, ,,,,,,,,,,,,,,,,,,,,,,, , ,, TROUBLESHOOTING POINTS
I ii iiiiiiiiiiii i I i iiiiiiiiiii ii IL== ,H ,=, ,,, TROUBLESHOOTING CHART
CAUSE
,,, i ,,,,,,,, , ,i J
Unit fails to operate.
A. Switch in the OFF position.
A. Push switch to the ON position.
B. Disconnected from power source. C. Circuit breaker tripped, or fuse
B. Reconnect unit to power source. C. Reset circuit breaker, or replace fuse.
blown. D. Mechanical failure.
D. Contact your Sears Service/Dept.
Unit vibrates abnormally.
A. Mechanical failure.
A. Contact your Sears Service/Dept.
u
A. Debris in air intake area. B. Mechanical failure.
Impeller will not tum freely.
A. Clean unit. Remove any debds. B. Contact your Sears Service/Dept.
ff situations occur which are not covered in this manual, use care and good judgement.
ff you need assistance, contact your Sears Service Center!Department or the CUSTOMER ASSISTANCE HOTLINE at 1-800-235-5878
, ,,,,,,,,,, · - ]3 -


12 AMP MOTOR 165 MPH Air Velocity E BLOWER/VAC
Operator's Manual
Model No.
358.798380
Each Electric BlowerNac has its own model number. The model number for your unit will be found on a decal attached to the unit. All parts listed herein may be ordered through Sears, Roebuck and Co. Service Centers and most Retail Stores.
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION
Your Sears merchandise has added value when you consider that Sears has service units nationwide staffed with Sears trained techni- cians.., professional technicians specifically trained on Sears prod- ucts, having the parts, tools and the equipment to insure that we meet our pledge to you, we service what we sell.
i HOURs (csn i ! Mon.-Sat. 7a.m.-7 p.m. ! I Sun. 10 a.m. - 7 p.m. j
Sears, Roebuck and Co., Hoffman Estates, IL 60179 USA
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.