Instruction/ maintenance manual of the product P400 Unigreen
Go to page of 36
09/2006 USE AND MAINTENANCE MANU AL MISTBLO WERS TURBO TEUT ON MOUNTED MISTBLO WERS serie TURBO TEUT ON - TT : P P olipo - P SuperSpalliera - R V -GD V Read this manual carefully bef ore use.
2 unigreen Summary 1 USING AND KEEPING THE USE AND MAINTENANCE MANU AL ...................................... 4 1.1 COMPOSITION OF THE MANUAL ................................................................................................... .... 4 1.
unigreen 3 6.2 DESCRIPTION OF TYPE OF NOZZLES ............................................................................................ 20 6.2.2 LO W V OLUME CONICAL NOZZLES (150-500L/HA) ............................................................
4 unigreen Thank you f or having chosen UNIGREEN. The product you purchased has been designed and b uilt with the greatest attention to the safety of the oper ator and the environment, ne v er theless there are still some residual risks due to the nature of the product used.
unigreen 5 2 SAFETY REGULA TIONS AND RESIDU AL RISKS In relation to saf ety , the f ollowing terms will be used: Dangerous zones: any z one inside and/or near the machine where the presence of a person e xposed constitutes a r isk f or the safety and health of the same person.
6 unigreen 2.1 INTENDED USE The spra yer in this series is b uilt for agricultural use. The materials used are resistant to nor mal chemical products used in agricultural spra ying (or herbicides) at the time of construction.
unigreen 7 Ref er to the enclosed handbooks for the use and maintenance of the pump and pressure regulator and any accessories or motors. b) Please contact the agent in your z one, the nearest authorised workshop or UNIGREEN S.p .A. directly for an y repairs the user feels the y aren’t capable of perf or ming alone.
8 unigreen 3.2 NOISE LEVEL OF THE MA CHINE Use earmuffs to protect your ears when using the machine, belo w you will find the data on the maximum noise le vels during work.
unigreen 9 4.2 PRELIMINAR Y CHECKS When you receiv e the machine, chec k that it is complete and no par ts are missing. If there are any damaged parts, inform your local reseller or UNIGREEN directly in good time.
10 unigreen 4.4 TRA CTOR COUPLING The tractor must ha ve 1”3/8 ASAE DIN 9611/A pow er-takeoff that runs at 550 r pm. It must hav e a 3-point elev ator suitable f or safely suppor ting the weight of the atomiser . Check this by consulting the tab le of allow ed fittings N° 17a (pages 34).
unigreen 11 4.5 CARD AN SHAFT In some models this is supplied on request. The cardan shaft must bear the CE mark. It must alwa ys hav e its own instructions that must be f ollowed scrupulously and it should come with a cov er bearing the mar k, integrated in e very par t.
12 unigreen 4.8 PRESSURE REGULA TOR T o use the pressure regulator , f ollow the instructions in the enclosed handbook scrupulously . The pressure regulator controls all of the most impor tant spraying functions , the thorough knowledge of its functions mak es work easier and more precise.
unigreen 13 = adjust maximum pressure v alv e B to the wor king v alue (in any case less than the safe maxim um pressure the system can reach). Pressure regulators with a v olumetric v alve (GCP ELETTRICO) Adjusting the maximum pressure v alve = put main control A in the dr ain position (“OFF”).
14 unigreen 4.10 FILLING THE T ANK The machines f or defensiv e crop treatments, in consideration of the saf ety of persons, animals and the protection of the en vironment, must only be filled indirectly from open water courses and only b y free-f alling water from the waterw or ks.
unigreen 15 4.12 MIXING The active principle can be mix ed using the rele vant stirrers bef ore and during the treatment. Correct mixing and stirring is the basis of the correct distribution on the crops. We recommend some useful accessories such as the premix er for po wders and liquids (see the following par agraph).
16 unigreen 4.1 3 W ASHING THE A TOMISER After ev er y treatment, thoroughly clean the equipment, washing it with water inside and out. Dir ty equipment is very dangerous for people and in particular f or children. Discharging the residues of washing in the en vironment without taking precautions is forbidden as this pollutes w ater courses.
unigreen 17 5 BLO WER GROUP All the mistblower s have a high speed fan r otor . Y ou must take great care and beware of the eff ects that this can pro voke: such as the aspiration and projection of f oreign bodies which, although of a small size, can be very dangerous especiall y for the ey es and face .
18 unigreen 5. 3 DISTRIBUT OR ACCESSORIES V arious configurations of accessor ies or distributors are fitted to the outlet of the fans . At present these are: P olipo - Super Spalliera - R V GDC W ARN.
unigreen 19 5. 4 HYDRA ULICS The R V , VL, VLX, FXF and FXL model distributor accessories hav e h ydraulics that can be controlled by the operator directly from the seat in the cab . Check that no one and nothing is in the area where the booms will open; par ticular attention should be paid to the presence of any electric power lines .
20 unigreen 6 SPRA YING W ARNING: the indications to f ollow f or using chemical products are indicated in paragr aph 2.2.1. 6.1 DESCRIPTION OF THE DIFFUSERS The distributor accessories of the T urboT euton range are equipped with variab le diffusers (FIG.
unigreen 21 6.3 CALIBRA TING TURBO TEUT ON The tables on pages 26-31 let y ou easily calculate the distribution in litres/ hectare of the mistblo wers with the standard fittings , proceeding as indica.
22 unigreen 7 HAND LANCES When using hand lances bear in mind the follo wing notes: = Don’t direct the jet of liquid tow ards electr ic pow er lines or zones where there is electrical current, houses or where people might pass. = Don’t point the jet at people or animals.
unigreen 23 ov erheating. This lubr ication can be done with grease or oil: oil allows significantly higher speeds, in general g rease is used to lubricate bear ings with a vertical or inclined axis as it stays in the z one f or longer .
24 unigreen the instructions in the present user’ s handbook and in the enclosures of the pump , pressure regulator and accessories. 8.7 DEMOLITION AND DISPOSAL When the spra yer will be put out of ser vice you should w ash it with great care to remov e any residues of chemical product, f ollow the instructions in point 4.
unigreen 25 part description code single Ø18 non-drip jet for mistblower with diaphragm (1/4" mount) without nozzles 1224/0194F double Ø18 non-drip jet for mistblower with diaphragm (1/4" .
26 unigreen unigreen s pa Tabell a e rogaz ione i n Litri/ et ta ro Turbo Te uton 1 6 ge tt i Lt . / ha s pr eading r at e t able f or T ur bo T eut on 16 NO Z Z LE S I S O O L I V A -O l i v e I S O .
unigreen 27 uni gr een s pa Tabe l la e rogazi one in Li tr i / et t aro Tur bo Teut on 16 get t i Lt . / ha s pre ading rat e t able f or T urbo T eut on 16 NO Z Z LES ISO O LIVA - Oliv e ISO A R A N.
28 unigreen uni gr een s pa Ta bell a e rogazi one in Li t ri /et ta ro Turbo Te uton 2 0 ge tt i Lt . / ha s pre ading rat e t able f or T urbo T eut on 20 N O Z Z LE S ISO O LIVA - Oliv e ISO A R A .
unigreen 29 uni gr een s pa Tabe l la e rogazi one in Li tr i / et t aro Tur bo Teut on 20 get t i Lt . / ha s pre ading rat e t able f or T urbo T eut on 20 N O Z Z LE S ISO O LIVA - Oliv e ISO A R A.
30 unigreen uni gr een s pa Tabe l la e rogazi one in Li tr i / et t aro Tur bo Teut on 20 get t i Lt . / ha s pre ading rat e t able f or T urbo T eut on 20 NO Z Z LES ISO O LIVA - Oliv e ISO A R A N.
unigreen 31 uni gr een s pa Tabe l la e rogazi one in Li tr i / et t aro Tur bo Teut on GD C 20 get ti Lt . / ha s prea ding rat e t able f or T urbo T eut on G DC 20 NO Z Z LE S ISO O LIVA - Oliv e I.
32 unigreen T AB. 3 T ABLE OF DELIVER Y OF NOZZLES FOR A T OMISERS T ABLE 4-5 T ABLES OF DELIVER Y OF NOZZLES FOR HAND LANCES T ABLE OF DELIVER Y IN LITRES / MIN.
unigreen 33 T ABLE 7 T ABLE OF PROGRAMMED MAINTENANCE OPERA TION 8 h 50 h 300 h END OF SEASON Check the le vel and state of the oil 0 Check the accumulator pressure 0 Check the suction (hoses, pipes ,.
34 unigreen T AB.17B ALLOWED FITTINGS 2005 MO U N T ED AT O MISERS T YPE O F Poly ethy lene T ank MA CHINE T ABL E 17 a FI TTIN G Nomi nal c apac i ty ( L.
unigreen 35.
Descriptions, indicativ e illustrations, UNIGREEN S .P .A. reser ves the right to make v a riations or modifications without pr ior wa rning. via Rinaldi, 105 - Loc. Cavazzoli (Reggio Emilia) - ITALY Tel. +39 0522 369811 Fax. +39 0522 369898 e-mail: info@unigreen-spa.
An important point after buying a device Unigreen P400 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Unigreen P400 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Unigreen P400 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Unigreen P400 you will learn all the available features of the product, as well as information on its operation. The information that you get Unigreen P400 will certainly help you make a decision on the purchase.
If you already are a holder of Unigreen P400, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Unigreen P400.
However, one of the most important roles played by the user manual is to help in solving problems with Unigreen P400. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Unigreen P400 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center