Instruction/ maintenance manual of the product RET232EUT Traulsen
Go to page of 16
This T raulsen unit is built to our highest quality standards. We build our refrigerators, freezers and heated cabinets this way as a matter of pride. This philosophy has made Traulsen the leader in commercial refrigeration since 1938.
T ABLE OF CONTENTS The serial tag is a permanently afxed sticker on which is recorded vital electrical and refrigeration data about your T raulsen product, as well as the model and serial number .
-2- II. RECEIPT INSPECTION All T raulsen products are factory tested for performance and are free from defects when shipped. The utmost care has been taken in crating this product to protect against damage in transit. All interior ttings have been carefully secured and the legs or casters are boxed and strapped inside to prevent damage.
-3- III. d - TRA Y SLIDES: Reach-In models are supplied with fourteen (14) pairs of #1 type tray slides on 4” centers. These are shipped installed from the factory , and are easily removable for cleaning without tools. III. e - CORD & PLUG: Most self-contained models are supplied with a cord & plug attached.
-4- IV . d - BA TCH LOADING: The Even-Thaw model can accommmodate any size partial load, or up to twenty eight (28) 18” x 26” pans of product. Use of aluminum pans is highly recommended. Product should be placed on pans in one layer only to allow for proper air ow .
-5- VI. a - SERVICE INFORMA TION: Before calling for service, please check the following: Is the electrical cord plugged in? Is the fuse OK or circuit breaker on? Is the power switch “ON”? If after checking the above items and the unit is still not oper - ating properly , please contact an authorized T raulsen service agent.
VII. a - INTRODUCTION/OVERVIEW : The T raulsen Even Thaw is designed to be used as a thawing cabinet. While it may be utilized in a refrigeration mode, that is not its intended use. Its function is to hold the cabinet temperature in the range from 38 to 40 degrees to thaw product within the food-safe temperature zone.
-7- VIII. e - INCOMPLETE THA WING: In operation, incomplete thawing (i.e. bags of product in which not every piece was completely thawed) has been found to usually be the result of those pkgs. respective pan level having had restricted airow due to overloading (from stacked pkgs.
IX. TROUBLE SHOOTING GUIDE -8- FIND YOUR PROBLEM HERE REMEDY 1. Condensing unit fails to start. a. Check if cord & plug has been disconnected. 2. Condensing unit operates for a. Are doors closing properly? prolonged periods or continuously . b. Dirty condenser or lter .
-9- X. SP ARE P ARTS LIST MODEL DESCRIPTION P ART NUMBER RE132E-FHS FULL HEIGHT DOOR GASKET 341-60105-00 TXV V AL VE 404A 325-60080-08 LIGHT BULB 378-29776-00 MIT II CONTROL MODULE 1 10V 337-60317-60 .
-10- XI. WIRING DIAGRAM ALL ONE SECTION MODELS ONL Y.
-1 1- XI. WIRING DIAGRAM MODELS RET232NUT -FHS & RET232NUT -HHS ONL Y.
XI. WIRING DIAGRAM MODELS RET232EUT -FHS & RET232EUT -HHS ONL Y -12-.
XII. W ARRANTY INFORMA TION -13- ST AN DARD DOM ESTIC W ARR ANTY TRA ULSEN warran ts new equipme nt to the original pu r cha se r, when installed within the Uni t ed St at es against de f ec ti ve m at erial and w ork manship f or three (3) y ear s fr om the d at e of orig ina l installation.
Notes:.
T raulsen 4401 Blue Mound Road Fort Worth, TX 76106 Phone: (800) 825-8220 Fax-Svce: (817) 740-6757 Website: www .traulsen.com HOURS OF OPERA TION: Monday thru Friday 7:30 am - 4:30 pm CST Quality Refr.
An important point after buying a device Traulsen RET232EUT (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Traulsen RET232EUT yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Traulsen RET232EUT - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Traulsen RET232EUT you will learn all the available features of the product, as well as information on its operation. The information that you get Traulsen RET232EUT will certainly help you make a decision on the purchase.
If you already are a holder of Traulsen RET232EUT, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Traulsen RET232EUT.
However, one of the most important roles played by the user manual is to help in solving problems with Traulsen RET232EUT. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Traulsen RET232EUT along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center