© 2002 American Standard Inc. All Rights Reserved 2 22-1640-06-0702 (EN) General Featur es Natural Gas Models Central Heating furnace designs are cer tified by the American and Canadian Gas Associations for both natur al and L.
22-1640-06-0702 (EN) 3 Contents General Features 2 Features and Benefits 4 Standard Equipment 4 Optional Equipment 5 General Data 6 TUD040C924K 6 TUD040C930K 6 TUD060C924K 6 TUD060C936K 6 TUD080C924K .
4 22-1640-06-0702 (EN) Featur es and Benefits • P o wer supply 115/1/60 • Multi-por t In-shot b ur ners • Integrated solid state control with self diagnostics • Silicon Nitride hot surface ign.
22-1640-06-0702 (EN) 5 Optional Equipment Thermostat .............................................................................................................................................................. BA Y ST A T388 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Hor izontally) .
6 22-1640-06-0702 (EN) General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 For U . S. applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele vations abo ve 2,000 f ee t above sea lev el.
22-1640-06-0702 (EN) 7 General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 F or U.S . applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele v ations above 2,000 f ee t above sea le vel.
8 22-1640-06-0702 (EN) General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 For U . S. applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele vations abo ve 2,000 f ee t above sea lev el.
22-1640-06-0702 (EN) 9 General Data 1 Central Furnace heating designs are cer tified by A GA and CSA. 2 F or U.S . applications, abov e input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 f eet for ele v ations above 2,000 f ee t above sea le vel.
10 22-1640-06-0702 (EN) Per for mance Data FURN AC E AIRFLO W (CFM) VS. ST A TIC PRESSU RE (ins. w .g.) M OD EL SP EE D T AP 0.1 0 0.2 0 0.3 0 0.4 0 0.
22-1640-06-0702 (EN) 11 Per for mance Data FURNACE AI RFL O W (C FM) VS. ST A T I C PR ESSURE ( i ns. w . g. ) M O DE L S P E E D T A P 0 .10 0 .20 0 .30 0 .40 0 .50 0 .6 0 0 .70 0 .80 0 .90 TUD1 00 C97 2K BO TTOM AND LEFT SIDE RET URN 4 - 3 - 2 - 1 - HI GH - Bl ack M E D .
12 22-1640-06-0702 (EN) Field Wiring F rom Dwg. 21B341437 Rev . 1 F rom Dwg. 21B341436 Re v . 1 Field Wiring Diagram For Single Stage Heating/Cooling (Outdoor Section Without T ransformer) Field Wirin.
22-1640-06-0702 (EN) 13 F rom Dwg. 21B341423 Rev . 1 F rom Dwg. 21B341422 Rev . 1 T winning Field Wiring.
14 22-1640-06-0702 (EN) F rom Dwg. 21C341699 Re v . 1 TUD-C Outline Drawing (All dimensions are in inches).
22-1640-06-0702 (EN) 15 Electrical Data Schematic Diagrams f or Gas Furnaces F rom Dwg. 21D341704 Rev . 1.
P .I. T rane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
An important point after buying a device Trane FURN-PRC001-EN (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Trane FURN-PRC001-EN yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Trane FURN-PRC001-EN - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Trane FURN-PRC001-EN you will learn all the available features of the product, as well as information on its operation. The information that you get Trane FURN-PRC001-EN will certainly help you make a decision on the purchase.
If you already are a holder of Trane FURN-PRC001-EN, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Trane FURN-PRC001-EN.
However, one of the most important roles played by the user manual is to help in solving problems with Trane FURN-PRC001-EN. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Trane FURN-PRC001-EN along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center