EN
Acer logo
Official user manual

Acer Panel PC 1000

34 pages·184 KB·Personal Computer·PDF·ENDEFRITNLJA
Acer Panel PC 1000
Table of Contents 72 sections Disclaimers · FCC Compliance · C · C h a p t e r 1 · … ShowHide
Disclaimersp.2FCC Compliancep.3Cp.9C h a p t e r 1p.91.1 General Descriptionp.91.2 Specificationsp.10Core System for system boardp.10I/O Systemp.10Built-in Peripheralsp.11System Specificationp.111.3 Dimensionsp.121.4 I/O Outletsp.131p.141.5 Utilities Supportedp.14C h a p t e r 2p.152p.152.1 System Configurationp.152.1.1 Front Viewp.152.2 Panel Mountp.16C h a p t e r 3p.173.1 CPUp.183.2 DRAMp.183.3 HDDp.193.4 4 x Serial Portsp.203.5 Parallel Portp.213.6 VGAp.213.7 Ethernetp.213.8 Digital I/Osp.223p.223.9 Keyboardp.223.10 PS/2 Mousep.223.11 External FDDp.233p.243.12 Expansion Slotp.243.13 System O/S and Software Installationp.25A p p e n d i x Ap.27Standard AC Power Suppliesp.27PANEL PC 1000 Power Supplyp.27Specificationsp.27Output Specificationsp.27Input Specificationsp.27General Specificationsp.28Environmental Specificationsp.28International Standardsp.28Safety Standardsp.28EMI Standardsp.28CE Standardsp.28Optional DC Power Suppliesp.29(I) +12V DC Power Supplyp.29Input Specificationsp.29Output Specificationsp.29General Featuresp.30Environmental Specificationsp.30International Standardsp.30Safety Standardsp.30EMI Standardsp.30(II) +24V DC Power Supplyp.31Input Specificationsp.31Output Specificationsp.31General Featuresp.32Environmental Specificationsp.32International Standardsp.32Safety Standardsp.32EMI Standardsp.32(III) +48V DC Power Supplyp.33Input Specificationsp.33Output Specificationsp.33General Featuresp.34Environmental Specificationsp.34International Standardsp.34Safety Standardsp.34EMI Standardsp.34
Page 1 of the Acer Panel PC 1000 user manual — All-in-One 10.4” Super Slim PANEL PC
Page 1 · click to enlarge
Page 1

PANEL PC 1000

All-in-One 10.4” Super Slim PANEL PC

User’s Manual

Page 2 of the Acer Panel PC 1000 user manual — Disclaimers
Page 2 · click to enlarge
Page 2

Disclaimers

The information in this manual has been carefully checked and is believed to be accurate. ACNODES assumes no responsibility for any infringements of patents or other rights of third parties, which may result from its use.

ACNODES assumes no responsibility for any inaccuracies that may be contained in this document. ACNODES makes no commitment to update or to keep current the information contained in this manual.

ACNODES reserves the right to make improvements to this document and/or product at any time and without notice.

No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of ACNODES.

Copyright 2002 by ACNODES All rights reserved. May 2002, Version A1

Page 3 of the Acer Panel PC 1000 user manual — FCC Compliance
Page 3 · click to enlarge
Page 3

Safety Approvals

!"FCC Class A

FCC Compliance

This equipment has been tested and complies with the limits for a Class-A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. If not installed and used in accordance with proper instructions, this equipment might generate or radiate radio frequency energy and cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measurers:

1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.

Shielded interface cables must be used in order to comply with emission limits.

!"CE Marking

Page 4 of the Acer Panel PC 1000 user manual — Safety Precautions
Page 4 · click to enlarge
Page 4

Safety Precautions

Before getting started, read the following important cautions.

1. The PANEL PC 1000 does not come equipped with an operating system. An operating system must be loaded first before installing any software into the computer.
2. Be sure to ground yourself to prevent static charge when installing the internal components. Use a grounding wrist strap and place all electronic components in any static-shielded devices. Most electronic components are sensitive to static electrical charge.
3. Disconnect the power cord from the PANEL PC 1000 before making any installation. Be sure both the system and the external devices are turned OFF. Sudden surge of power could ruin sensitive components. Make sure the PANEL PC 1000 is properly grounded.
4. The brightness of the flat panel display decreases with usage. However, hours of use vary depending on the application environment.

5. Turn OFF the system power before cleaning. Clean the system using a cloth only. Do not spray any liquid cleaner directly onto the screen. The PANEL PC 1000 may come with or w/o a touch screen. Although the touch screen is chemical resistant, it is recommended that you spray the liquid cleaner on a cloth first before wiping the screen. In case your system comes without the touch screen, you must follow the same procedure and not spray any cleaner on the flat panel directly.

6. Avoid using sharp objects to operate the touch screen. Scratches on the touch screen may cause malfunction or internal failure to the touch screen.
7. The flat panel display is not susceptible to shock or vibration. When assembling the PANEL PC 1000, make sure it is securely installed.
Page 5 of the Acer Panel PC 1000 user manual — Trademarks Acknowledgments
Page 5 · click to enlarge
Page 5
8. Do not open the system’s back cover. If opening the cover for maintenance is a must, only a trained technician is allowed to do so. Integrated circuits on computer boards are sensitive to static electricity. To avoid damaging chips from electrostatic discharge, observe the following precautions:

#"Before handling a board or integrated circuit, touch an

unpainted portion of the system unit chassis for a few seconds. This will help to discharge any static electricity on your body.

#"When handling boards and components, wear a

wrist-grounding strap, available from most electronic component stores.

Trademarks Acknowledgments

ACNODES is a trademark of ACNODES Inc.

ALI is a trademark of Acer Laboratories, Inc.

AMD is a trademark of Advanced Micro Devices, Inc.

AMI is a trademark of American Mega trends, Inc.

Cyrix is a trademark of Cyrix Corporation.

ELO is a trademark of ELO Touch Systems, Inc.

IBM, PC/AT, PS/2, VGA are trademarks of International Business Machines Corporation.

Intel and Pentium are trademarks of Intel Corporation.

MS-DOS, Microsoft C and Quick BASIC are trademarks of Microsoft Corporation.

SMC is a trademark of Standard Microsystems Corporation.

C&T is a trademark of Chips and Technologies, Inc.

SST is a trademark of Silicon Storage Technology, Inc.

UMC is a trademark of United Microelectronics Corporation.

Other brand names and trademarks are the properties of their respective owners.

Page 6 of the Acer Panel PC 1000 user manual — FCC Compliance
Page 6 · click to enlarge
Page 6

This page does not contain any information. This page does not contain any information. This page does not contain any information. This page does not contain any information.

Page 7 of the Acer Panel PC 1000 user manual — Table of contents
Page 7 · click to enlarge
Page 7

Table of contents

Disclaimersp.2FCC Compliancep.3Cp.9C h a p t e r 1p.91.1 General Descriptionp.91.2 Specificationsp.10Core System for system boardp.10I/O Systemp.10Built-in Peripheralsp.11System Specificationp.111.3 Dimensionsp.121.4 I/O Outletsp.131p.141.5 Utilities Supportedp.14C h a p t e r 2p.152p.152.1 System Configurationp.152.1.1 Front Viewp.152.2 Panel Mountp.16C h a p t e r 3p.173.1 CPUp.183.2 DRAMp.183.3 HDDp.193.4 4 x Serial Portsp.203.5 Parallel Portp.213.6 VGAp.213.7 Ethernetp.213.8 Digital I/Osp.223p.223.9 Keyboardp.223.10 PS/2 Mousep.223.11 External FDDp.233p.243.12 Expansion Slotp.243.13 System O/S and Software Installationp.25A p p e n d i x Ap.27Standard AC Power Suppliesp.27PANEL PC 1000 Power Supplyp.27Specificationsp.27Output Specificationsp.27Input Specificationsp.27General Specificationsp.28Environmental Specificationsp.28International Standardsp.28Safety Standardsp.28EMI Standardsp.28CE Standardsp.28Optional DC Power Suppliesp.29(I) +12V DC Power Supplyp.29Input Specificationsp.29Output Specificationsp.29General Featuresp.30Environmental Specificationsp.30International Standardsp.30Safety Standardsp.30EMI Standardsp.30(II) +24V DC Power Supplyp.31Input Specificationsp.31Output Specificationsp.31General Featuresp.32Environmental Specificationsp.32International Standardsp.32Safety Standardsp.32EMI Standardsp.32(III) +48V DC Power Supplyp.33Input Specificationsp.33Output Specificationsp.33General Featuresp.34Environmental Specificationsp.34International Standardsp.34Safety Standardsp.34EMI Standardsp.34
Page 8 of the Acer Panel PC 1000 user manual — FCC Compliance
Page 8 · click to enlarge
Page 8

This page does not contain any information. This page does not contain any information. This page does not contain any information. This page does not contain any information.

Page 9 of the Acer Panel PC 1000 user manual — 1.1 General Description
Page 9 · click to enlarge
Page 9

C h a p t e r 1

Introduction

This chapter contains the general information and the detailed specifications of the PANEL PC1000. Chapter 1 includes the following sections:

$"General Description $"System Specification $"Dimensions $"I/O Outlets $"Utilities Supported

1.1 General Description

The PANEL PC 1000 super slim industrial PANEL PCs are mainly designed for industrial automation and some space-constricted embedded applications. For some space-concerned industries, a traditional PC with a separate main system, display monitor and keyboard is simply not integrated enough.

Ruggedly designed, the PANEL PC 1000 is 100% IBM PC/AT compatible and it integrates super I/Os, VGA, 10.4” TFT, touch screen, Ethernet, and packs special industrial features like watchdog timer, CMOS double backup, all in a single system. The full PC functionality coupled with its industrial-grade construction easily tailors the system for any embedded applications and allows the system to endure continuous operation in any hostile industrial environments where stability and reliability are a must. Common applications of the PANEL PC 1000 include tooling machine, POI terminal, stand-alone KIOSK, medical instrument, mobile communication device and banking system - to name just a few.

Designed by the PC experts for PC professionals, the PANEL PC 1000 is virtually the ultimate one-step solution for your space-limited applications.

Introduction 1

Page 10 of the Acer Panel PC 1000 user manual — I/O System
Page 10 · click to enlarge
Page 10

1.2 Specifications

Core System for system board

$" CPUIntel Celeron 300 up to 733 MHz;

Intel Pentium III 500 up to1.0Ghz $"System Chipset: Intel 440BX Core Logic Controller $"BIOS: Award BIOS, Y2K compliant 2Mbit Flash ROM, DMI, Plug and Play $"System Memory: One 168-pin DIMM (PC-100)

Maximum SDRAM of up to 256MB $"L2 Cache: Integrated in CPU $"Real Time Clock: Dallas STM48T86PC1 or latest product $"Watchdog Timer: System reset or Non-Mask Interrupt

software programmable Time interval and jumper selectable; 64 levels, 0.5~8 / 5~80 / 50~800 / 100~1600 seconds

I/O System

$"Standard I/O:

− 4 x serial ports with power; 3 x RS-232, 1 x

RS-232/422/485 jumper selectable − 1 x parallel port, SPP/EPP/ECP − 1 x External FDD Interface − 2 x HDD Interface − 1 x Keyboard Interface − 1 x PS/2 Mouse Interface − 2 x USB Ports

$" Digital I/OInput x 4, Output x 4

$"Ethernet:

− 32-bit Plug & Play Fast Ethernet Controller − RJ-45 connector

$"Audio:

− ESS Solo-1 1938 32-bit PCI 2.1 Audio Drive controller $"VGA/Flat Panel Controller:

− AGP Interface C&T69000 controller with integrated 2MB

SDRAM − Simultaneously supports CRT and flat panel displays

Introduction 2

Page 11 of the Acer Panel PC 1000 user manual — System Specification
Page 11 · click to enlarge
Page 11

Built-in Peripherals

$"Standard 100W power supply $"2.5” Hard disk (540MB or up) $"10.4” ELO anti-glare analog resistive touch screen with

RS- 232 controller sharing COM3 $"System cooling fan

System Specification

$"10.4” TFT with 640 x 480 resolution

$"External FDD interface

$"NEMA 4/12 sealed front panel

$"Heat dispensing design

$"PC/104 expansion Bus

$"One free slot for PCI/ISA expansion

$" Net weight4.2 KGS

$"Dimension (main body size):

− PANEL PC 1000 − 330 x 266 x 93 mm (with

one ISA or PCI expansion card)

$" Operating Temperature Range0 o C ~ 40 o C $" Relative Humidity: 5% ~ 95%; non-condensing

Introduction 3

Page 12 of the Acer Panel PC 1000 user manual — PANEL1000-370 10.4" FLAT PANEL PC (unit: mm)
Page 12 · click to enlarge
Page 12

1.3 Dimensions

PANEL1000-370 10.4" FLAT PANEL PC (unit: mm)

Introduction 4

Page 13 of the Acer Panel PC 1000 user manual — 7. COM4
Page 13 · click to enlarge
Page 13

1.4 I/O Outlets

The following figure shows the I/O arrangement of the PANEL PC 1000. The backside of the chassis contains most of the connectors.

1. Ethernet RJ-45 phone jack

8. COM3

9. COM2

2. PS/2 mouse

10. COM1

3. Keyboard
11. VGA port IF
4. External FDD
12. AC inlet
5. 4-channel Digital Inputs/outputs
13. Power switch
14. +5V/12V DC outlet
6. Parallel port

7. COM4

Introduction 5

Page 14 of the Acer Panel PC 1000 user manual — 1.5 Utilities Supported
Page 14 · click to enlarge
Page 14

1.5 Utilities Supported

%"Touch screen Utility

Show 4 more labels / short text on this page
%"Watchdog Utility · %"Ethernet Utility · %"VGA Drivers · Introduction 6
Page 15 of the Acer Panel PC 1000 user manual — 2. HDD LED
Page 15 · click to enlarge
Page 15

C h a p t e r 2

System Configuration

This chapter details the system parts and components with figures. Sections include

$" System Major Parts $" Panel Mount

2.1 System Configuration

2.1.1 Front View

The figure below shows the front views of PANEL PC1000.

1. Power LED

2. HDD LED

3. Ethernet LED

System Configuration 7

Page 16 of the Acer Panel PC 1000 user manual — 2.2 Panel Mount
Page 16 · click to enlarge
Page 16

2.2 Panel Mount

The PANEL PC 1000 is mainly designed for panel mount application. To mount the PANEL PC 1000, the standard set of mounting kit (included in the system packaging) is needed. Please refer to the following figure.

8 System Configuration

Page 17 of the Acer Panel PC 1000 user manual — C h a p t e r 3
Page 17 · click to enlarge
Page 17

C h a p t e r 3

This chapter describes the installation and the cable connection to the system connectors. See system board User’s Manual that came with your PANEL PC packaging for more details. Sections in this chapter includes

$"CPU $"DRAM $"HDD $"4 x Serial

$"VGA $"Ethernet $"Digital I/O $"Keyboard $"PS/2 Mouse $"External FDD

Slot $"System O/S

Ports $"Parallel Port

The PANEL PC 1000 has a Pentium III little board with a free PCI/ISA slot inside. It already builds in a Pentium III CPU, relevant DRAM and a 2.5” HDD. These are all standard and the system is ready to play. System performance can be increased by upgrading to a higher performance CPU, higher capacity DRAM modules and hard disk drive. The user can use the I/O ports located at the back side of the chassis to connect external peripheral devices, such as a monitor, serial devices, parallel printer…etc.

$"Expansion · and Software Installation

Page 18 of the Acer Panel PC 1000 user manual — 3.2 DRAM
Page 18 · click to enlarge
Page 18

3.1 CPU

The standard PANEL PC 1000 system already builds in Pentium III-level CPU. When upgrading to a new CPU of the same level, follow the instructions below;

1. To remove the existing CPU requires the use of a chip puller.
2. Locate pin 1 at the corner of the CPU socket and align the CPU’s pin 1 with the pin 1 on the socket.
3. Place the CPU in the socket. If the insertion of the CPU to the socket is not easy, then check whether the notch on the corner of the CPU and the notch on the socket are properly aligned.
4. When a new CPU is installed, other settings on the system control board including CPU type, CPU bus clock and CPU voltage may need to be adjusted. Make sure all the settings are correct for the installed CPU. (See the CPU jumper settings in the CPU card User’s Manual that came with the PANEL PC packaging).

3.2 DRAM

The system control board provides 1 x 168-pin DIMM sockets supporting system memory up to 256MB.

To install the memory module;

1. Disconnect all power sources.
2. The memory module can only fit into the socket one way. Holding the memory module with the notch on the upper right corner, then insert the memory module at a 45 ° Angle and push the module upright until it clicks into place.

The system auto detects the new memory size and it is not necessary to change the system configuration after installation.

Page 19 of the Acer Panel PC 1000 user manual — 3.3 HDD
Page 19 · click to enlarge
Page 19

3.3 HDD

The standard PANEL PC 1000 already builds in a 2.5” hard disk drive. If the user intends to remove the existing device for repair or for a higher-capacity one, then follow the installation instructions below.

1. Take out the screws and remove the HDD bracket. Mounting orientation of the HDD brackets on PANEL PC 1000 are not similar to each other. The four screws mounting the PANEL PC 1000 HDD bracket sits at the bottom of the bracket.
2. Reinstall the new hard disk driver to the HDD bracket and screw the HDD bracket to the system compartment again. The four rubber stands act as cushions to lessen the vibration that usually causes damage to mechanical devices like a hard disk driver.
3. Use the IDE cable to connect the HDD to the IDE pin connector. Match pin 1 of the HDD and the pin 1 of the cable.
Page 20 of the Acer Panel PC 1000 user manual — R2-422 RS-485
Page 20 · click to enlarge
Page 20

3.4 4 x Serial Ports

The PANEL PC 1000 provides four onboard serial ports installed on the bottom rear side of the chassis. Arrangements on PANEL PC 1000 specify COM1, COM2, COM3 providing RS-232 interface, and with its RS-422/485 interface connected to COM4. Each serial port comes with +5V/+12V power capabilities on both Pin 1 and Pin 9, ready to accommodate a wide array of serial devices such as fax modem, scanner, serial mouse, touch screen...etc. If the touch screen option is included, its controller will share COM3.

COM1 to COM4 are all D-SUB 9-pin connectors. To attach to any serial device, just plug in the device connector to the 9-pin D-SUB. In terms of transmission distance, the RS-422/485 will perform better than RS-232. In this case, the COM2 is suggested to be set to RS-422/485 and the related jumpers have to be set correctly first (see the system board User’s Manual). The RS-485 pin assignment is listed below.

Signal Name Pin #

R2-422 RS-485

1 TX- DATA- 2 TX+ DATA+ 3 RX+ No connector 4 RX- No connector 5 GND GND 6 No connector No connector 7 No connector No connector 8 No connector No connector

1 2 3 4 5

6 7 8 9

9 No connector No connector

Page 21 of the Acer Panel PC 1000 user manual — RJ-45
Page 21 · click to enlarge
Page 21

3.5 Parallel Port

The printer interface is a 25-pin D-SUB connector. To connect any parallel device, just plug in the device connector to the 25-pin D-SUB.

3.6 VGA

The PANEL PC 1000 has an analog RGB interface connector. It is able to connect to an expansion CRT monitor, and the system can display on both the flat panel and the CRT simultaneously.

3.7 Ethernet

The PANEL PC 1000 provides an NE2000 compatible Ethernet (RJ-45) interface. For network connection, just plug in one cable end of the PANEL PC 1000 100-Base-T Hub into the standard Ethernet phone jack. The pin assignment of the RJ-45 is listed below;

RJ-45 Connector Pin Assignment

1 2 3 4 5 6 7 8

1 2 3 6 others

Tx+ (Data transmission positive) Tx- (Data transmission negative) Rx+(Data reception positive) Rx- (Data reception negative) Not use

RJ-45

Pin Description

Page 22 of the Acer Panel PC 1000 user manual — 3.10 PS/2 Mouse
Page 22 · click to enlarge
Page 22

3.8 Digital I/Os

The PANEL PC 1000 provides a digital I/O of 4-channel inputs/outputs for simple automation control. For example, it can be used to control the opening and closing of the cash drawer on a POS system. It can also be used for UPS control. It comes with a 15-pin D-SUB connector, and its pin position and pin assignment is shown on the following page.

Digital I/O Pin Assignment

P1 OUT 1 P9 GND

P2 OUT 2 P10 GND

1 2 3 4 5

P3 OUT 3 P11 IN1

P4 OUT4 P12 IN2

P5 GND P13 IN3

P6 GND P14 IN4

P7 GND P15 GND

P8 GND

3.9 Keyboard

The PANEL PC 1000 provides a standard PS/2 keyboard connector. If the user would like to use AT keyboard interface, a conversion cable is also provided to make this connection.

3.10 PS/2 Mouse

The PANEL PC 1000 has one PS/2 mouse connector. A simple plug-in will make the connection.

Show 28 more labels / short text on this page
· · · · · · · · · · · · · · 10 · 6 · 7 · 8 · 9 · · · · · 11 · 12 · 13 · 14 · 15
Page 23 of the Acer Panel PC 1000 user manual — P 1 SIDE1P 14 WPT-
Page 23 · click to enlarge
Page 23

3.11 External FDD

The PANEL PC 1000 does not build in any floppy disk drive into the main system. Rather, it provides a FDD interface. An external FDD cable is provided to connect a standard 3.5” FDD to the system for system O/S and application software installation. The pin positions and pin assignments are listed on the next page.

PANEL PC 1000 External FDD Pin Assignment

P 1 SIDE1P 14 WPT-

P 2 RDATAP 15 TRK0-

P 3 GND P 16 GND

P 4 GND P 17 WGATE-

P 5 GND P 18 GND

P 6 WDATAP 19 NC

P 7 REDWCP 20 STEP-

P 8 NC P 21 DIR-

P 9 NC P 22 MOTE0-

P 10 DRVS0P 23 NC

P 11 VCC +5V P 24 DSKCHG-

P 12 VCC P 25 NC

P 13 INDEXP 26 VCC

Page 24 of the Acer Panel PC 1000 user manual — 3.12 Expansion Slot
Page 24 · click to enlarge
Page 24

3.12 Expansion Slot

The PANEL PC 1000, this comes as a standard system feature. If the system comes with expansion capability, then the system includes a PCI/ISA expansion riser card to accommodate either an ISA or PCI device at a given time. Due to the internal space limitation, only a half-size expansion card can be adapted. To use the ISA or PCI expansion, refer to the following figure and follow the installation instructions below;

1. Plug the riser card into the onboard PCI/ISA slot first.
2. Screw the metal opening to the power supply bracket and the multi-I/O conversion metal piece.
3. Plug either an ISA or PCI card into the ISA or PCI slot on the riser card and screw the expansion card to the metal opening piece. All the connectors of the expansion card will come out from the opening on the rear cover for further cable connection.
4. Screw the rear cover to the chassis.

Please also note that the total height of the system with expansion slot is 93 mm.

Page 25 of the Acer Panel PC 1000 user manual — 3.13 System O/S and Software Installation
Page 25 · click to enlarge
Page 25

3.13 System O/S and Software Installation

The PANEL PC 1000 is not equipped with any operating system. It builds in a 2.5” HDD and 1.5MB Solid State Disk as memory storage device. As both devices are built in the system chassis, to load any O/S or application software into the computer, an external device is needed to act as a bridge. There are three major ways to load software into the system.

1. Use an external FDD: Attach a 3.5” FDD to the external FDD port via the provided external FDD cable.26-pin FDD connector must be plugged into the system FDD connector; the 34-pin standard 3.5” FDD signal connector and the 4-pin FDD power connector are connected to the standard 3.5” FDD. Then, configure the system BIOS setup and insert a 3.5” disk containing necessary software and start the installation.
2. Use Ethernet: If the Ethernet BOOTROM is already included in the system, the user can boot up the system via BOOTROM and download system O/S or application software from the net.
3. Use External CD-ROM/ HDD: When using an external CD-ROM or HDD for software installation on P PANEL PC 1000 an optional P-IDE device is needed. The P-IDE device is a converter to convert the parallel port to the IDE interface.
Page 26 of the Acer Panel PC 1000 user manual — 3.13 System O/S and Software Installation
Page 26 · click to enlarge
Page 26

This page does not contain any information. This page does not contain any information. This page does not contain any information. This page does not contain any information.

Page 27 of the Acer Panel PC 1000 user manual — Input Specifications
Page 27 · click to enlarge
Page 27

A p p e n d i x A

Power Supply Specifications

Standard AC Power Supplies

PANEL PC 1000 Power Supply

The power supply used in the PANEL PC 1000 is a 100W open frame power supply. The specifications and features of this special power supply are listed in the following sections.

Specifications

$"High efficiency 100W output $"Universal input 100 to 240 VAC $"Over-voltage protection $"Small size 3” X 5” footprint $"Continuous short circuit protection $"Conductive EMI meets FCC class B

Output Specifications

%" +5V DC primary output: + 5%

%" Auxiliary output+ 5% $" Total output power
%" Convection cooled100W

%"Forced air cooling: 125W @ 25CFM $"Hold-up time: 50ms type. $"Over-voltage protection: approx. 5.8V $"Short circuit protection: Continuous $"Ripple and noise: 1% peak ~ peak max.

Input Specifications

$"Input voltage range: 100~240 VAC $"Inrush current: 2.4A at 100VAC or 30A at 240VAC (cold start) $"Input frequency: 47~63 Hz $"Line regulation: + 1%

Power Supply Specifications 19

$"Voltage Accuracy

Page 28 of the Acer Panel PC 1000 user manual — CE Standards
Page 28 · click to enlarge
Page 28

General Specifications

$"Efficiency: 86% typ.

Environmental Specifications

$"Operating temperature range: 0°C to 40°C $"Storage temperature range -40°C to +85°C $"Humidity, non-condensing: 5% ~ 95% $"Altitude: 0 to 10,000 feet

International Standards

Safety Standards

$"Designed to meet the following standards:

UL 1950, CSA 22.2 NO. 234, VDE EN 60 950

EMI Standards

$"Designed to meet the following limits:

FCC docket 20780 curve “B”, EN55022 “B”

CE Standards

$"Designed to meet the following standards:

IEC-801-2 Level 3 8KV air discharge IEC-801-3 Level 3 3V/M IEC-801-4 Level 3 2KV IEC-801-5 Level 3 2KV

Power Supply Specifications 20

Page 29 of the Acer Panel PC 1000 user manual — Output Specifications
Page 29 · click to enlarge
Page 29

Optional DC Power Supplies

(I) +12V DC Power Supply

Input Specifications

$"Input voltage range: +9VDC to +18VDC $"Input current: 10A at +12VDC max.

Output Specifications

$"Load Range:

Output Min. Load Rated Load Voltage Accuracy

+5V 0A 10A 4.95V to 5.05V

+12V 0A 1.5A (open) 11.4V to12.6V

-12V 0A 0.3A -11.4V to –12.6V

The output range of +12V, -12V and down with +5V setting. At factory, all outputs in 60% rated load conditions, the +5V output is set to between 4.95V and 5.05V, and the other outputs are checked to be within the specified voltage accuracy range. $"Ripple and Noise:

The peak-to-peak ripple and noise for +5V output is less than 50mV and less than 100mV for +/-12V outputs, both at rated loads. Measuring is done by 15MHz bandwidth limited oscilloscope and terminated each output with 0.47uF capacitor. $"Line Regulation:

The line regulation for +5V output is less than +/-1%, for 12V is less than +/-2%, for –12V is less than +/-3% while measuring at rated loading and +/-10% of input voltage changing. $"Load Regulation:

The load regulation for +5V, +12Vare less than +/-3%, for -12V is less than +/-5%, measuring is done by changing the measured output loading +/-40% from 60% rated load, and keep other output at 60% rated load.

Power Supply Specifications 21

Page 30 of the Acer Panel PC 1000 user manual — EMI Standards
Page 30 · click to enlarge
Page 30

General Features

$"Efficiency:

The efficiency is 70% typical while measuring at nominal line and rated load. $"Protection:

For some reason the power supply fails to control itself, the built-in over-voltage protection circuit will shut down the outputs to prevent damage to external circuits. The trip point of crowbar circuit is around 5.7V to 7.0V. The power supply will go into latch-off mode against short circuit or over load conditions, and have to turn OFF and then ON the DC input to restart the power supply.

Environmental Specifications

$"Operating temp. range: 0°C to 50°C with forced air 20cfm $"Storage temperature range: -40°C to +85°C

International Standards

Safety Standards

$"Designed to meet the following standards:

UL 1950, CSA 22.2 NO. 234, TUV/LVD EN60 950

EMI Standards

$"Designed to meet the following limits::

FCC docket 20780 curve “B”, EN55022 “B”

Power Supply Specifications 22

Page 31 of the Acer Panel PC 1000 user manual — Output Specifications
Page 31 · click to enlarge
Page 31

(II) +24V DC Power Supply

Input Specifications

$"Input voltage range: +18VDC to +36VDC $"Input current: 5A at +24VDC max.

Output Specifications

$"Load Range:

Output Min. Load Rated Load Voltage Accuracy

+5V 0A 10A 4.95V to 5.05V

+12V 0A 1.5A (open) 11.4V to12.6V

-12V 0A 0.3A -11.4V to –12.6V

The output range of +12V, -12V and down with +5V setting. At factory, all outputs in 60% rated load conditions, the +5V output is set to between 4.95V and 5.05V, and the other outputs are checked to be within the specified voltage accuracy range. $"Ripple and Noise:

The peak-to-peak ripple and noise for +5V output is less than 50mV and less than 100mV for +/-12V outputs. Measuring is done by 15MHz bandwidth limited oscilloscope and terminated each output with 0.47uF capacitor. $"Line Regulation:

The line regulation for +5V output is less than +/-1%, for +12V is less than +/-2%, for –12V is less than +/-3% while measuring at rated loading and +/-10% of input voltage changing. $"Load Regulation:

The load regulation for +5V is less than +/-3%, for +12V is less than +/-5%, -12V is less than +7% -3%, measuring is done by changing the measured output loading +/-40% from 60% rated load, and keep other output at 60% rated load.

Power Supply Specifications 23

Page 32 of the Acer Panel PC 1000 user manual — EMI Standards
Page 32 · click to enlarge
Page 32

General Features

$"Efficiency:

The efficiency is 75% typical while measuring at nominal line and rated load. $"Protection:

For some reason the power supply fails to control itself, the built-in overvoltage protection circuit will shut down the outputs to prevent damage to external circuits. The trip point of crowbar circuit is around 5.7V to 7.0V. The power supply will go into latch-off mode against short circuit or over load conditions, and have to turn OFF and then ON the DC input to restart the power supply.

Environmental Specifications

$"Operating temp. range: 0°C to 50°C with forced air 20cfm $"Storage temperature range: -40°C to +85°C

International Standards

Safety Standards

$"Designed to meet the following standards:

UL 1950, CSA 22.2 NO. 234, TUV/LVD EN60 950

EMI Standards

$"Designed to meet the following limits:

FCC docket 20780 curve “B”, EN55022 “B”

Power Supply Specifications 24

Page 33 of the Acer Panel PC 1000 user manual — Output Specifications
Page 33 · click to enlarge
Page 33

(III) +48V DC Power Supply

Input Specifications

$"Input voltage range: +36VDC to +72VDC $"Input current: 3A at +48VDC max.

Output Specifications

$"Load Range:

Output Min. Load Rated Load Voltage Accuracy

+5V 0A 10A 4.95V to 5.05V

+12V 0A 1.5A 11.4V to12.6V

-12V 0A 0.3A -11.4V to –12.6V

At factory, all outputs in 60% rated load conditions, the +5V output is set to between 4.95V and 5.05V, and the other outputs are checked to be within the specified voltage accuracy range. $"Ripple and Noise:

The peak-to-peak ripple and noise for +5V output is less than 60mV and less than 100mV for +/-12V outputs. Measuring is done by 15MHz bandwidth limited oscilloscope and terminated each output with 0.47uF capacitor. $"Line Regulation:

The line regulation for +5V output is less than +/-1%, for +12V is less than +/-2%, for –12V is less than +/-3% while measuring at rated loading and +/-10% of input voltage changing. $"Load Regulation:

The load regulation for +5V is less than +/-3%, for +12V is less than +/-5%, -12V is less than +7% -3%, measuring is done by changing the measured output loading +/-40% from 60% rated load, and keep other output at 60% rated load.

Power Supply Specifications 25

Page 34 of the Acer Panel PC 1000 user manual — EMI Standards
Page 34 · click to enlarge
Page 34

General Features

$"Efficiency:

The efficiency is 75% typical while measuring at nominal line and rated load. $"Protection:

For some reason the power supply fails to control itself, the built-in over-voltage protection circuit will shut down the outputs to prevent damage to external circuits. The trip point of crowbar circuit is around 5.7V to 7.0V. The power supply will go into latch-off mode against short circuit or over load conditions, and have to turn OFF and then ON the DC input to restart the power supply.

Environmental Specifications

$"Operating temp. range: 0°C to 50°C with forced air 20cfm $"Storage temperature range: -40°C to +85°C

International Standards

Safety Standards

$"Designed to meet the following standards:

UL 1950, CSA 22.2 NO. 234, TUV/LVD EN60 950

EMI Standards

$"Designed to meet the following limits:

FCC docket 20780 curve “B”, EN55022 “B”

Power Supply Specifications 26

Ask about the Acer Panel PC 1000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Acer Panel PC 1000

Be the first to ask — other owners or our team will answer.

Original document

Acer Panel PC 1000 manual PDF

34 pages·184 KB·Personal Computer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…