Topp.1FOREWORDp.3General Handling Precautionsp.3Display for Safe Usep.5Safety Cautionsp.5Userp.6Exceptions from Responsibilityp.6Laser Safetyp.7Contentsp.8Standard Set Compositionp.111 NOMENCLATURE AND FUNCTIONSp.121.1 Nomenclaturep.121.2 Displayp.141.3 Operating Keyp.151.4 Function Key (Soft Key)p.161.5 Star key (*key) modep.181.6 Auto Power Offp.221.7 Data Outputp.221.8 Rotating Methodp.221.8.1 Rotating by H/V Shuttle and H/V Jogp.221.8.2 Auto Inversionp.221.8.3 Rotating automatically to a required Horizontal and Vertical anglep.221.9 Using together with RC-2II Remote Control Systemp.231.10 Using connecting with Personal Computer (PC)p.242 PREPARATION FOR MEASUREMENTp.252.1 Power Connectionp.252.2 Setting Instrument Up For Measurementp.262.3 Power Switch Key ONp.272.4 Battery Level Indicatorp.282.5 Main Menu Iconsp.292.6 Vertical and Horizontal Angle Tilt Correctionp.302.7 Compensation of Systematic Error of Instrumentp.312.8 Resume Mode ON/OFFp.322.9 How to Enter Numerals and Alphabet Lettersp.322.10 Memory Cardp.332.11 Inclination of Prism and Measuring Errorp.343 AUTOMATIC TRACKING / AUTOMATIC COLLIMATIONp.363.1 Automatic Trackingp.363.2 Automatic Collimationp.383.3 Range of Laser for Auto-tracking and Auto-collimatingp.393.4 Setting Parameters for Auto-Trackingp.403.4.1 Setting Itemsp.403.4.2 How to set the parametersp.424 STANDARD MEASUREMENT MODEp.434.1 Angle Measurementp.434.1.1 Measuring Horizontal Angle Right and Vertical Anglep.434.1.2 Switching Horizontal Angle Right/Leftp.444.1.3 Measuring from the Required Horizontal Anglep.444.1.4 Vertical Angle Percent Grade(%) Modep.454.1.5 Automatic Rotation to a Required Horizontal and Vertical Absolute Anglep.464.2 Distance Measurementp.474.2.1 Setting of the Atmospheric Correctionp.474.2.2 Setting of the Correction for Prism Constantp.474.2.3 Distance Measurement (Continuous Measurement)p.474.2.4 Distance Measurement (Single/N-times Measurement)p.484.2.5 Fine / Coarse Measuring Modep.504.2.6 Stake Out (S-O)p.514.3 COORDINATE MEASUREMENTp.524.3.1 Setting Coordinate Values of Occupied Pointp.524.3.2 Setting of the Instrument Height / Prism Heightp.544.3.3 Execution of Coordinate Measuringp.554.4 DATA OUTPUTp.575 PROGRAM MODESp.595.1 Setting a Direction Angle for Backsight Orientationp.605.2 Retaining a Coordinate (STORENEZ)p.615.3 Remote Elevation measurement (REM)p.635.4 Missing Line Measurement (MLM)p.665.5 Line Measurement (LINE)p.695.6 Offset measurement (OFFSET)p.725.6.1 Angle Offsetp.735.6.2 Distance Offset Measurementp.755.6.3 Plane Offset Measurementp.775.6.4 Column Offset Measurementp.795.7 External Linkp.815.7.1 Starting compatible communication program of AP-L1Ap.815.7.2 Setting for the communicationp.815.7.3 Carrying out Communicationp.856 MEMORY MANAGE MODESp.866.1 View Internal Memory and Card Memory Statusp.866.2 Protect a Filep.876.3 Rename a Filep.876.4 Deleting a Filep.886.5 Copy a Filep.886.6 Initializing Memoryp.897 COMMUNICATION MODESp.907.1 Setting of PROTOCOLp.907.2 Data File Inp.917.3 Data File Outp.918 PARAMETERS SETTING MODEp.928.1 Parameter Setting Optionsp.928.1.1 Parameters for Measurement and Displayp.928.1.2 Parameters for communicationp.948.2 Setting Parametersp.968.2.1 Parameters for Measurement and Displayp.968.2.2 Parameters for Communicationp.978.2.3 Password Optionp.979 CHECK AND ADJUSTMENTp.1009.1 Checking and Adjusting of Instrument Constantp.1009.2 Checking the Optical Axisp.1019.3 Checking/Adjusting the Theodolite Functionsp.1039.3.1 Checking /Adjusting the Plate Levelp.1049.3.2 Checking /Adjusting the Circular Levelp.1049.3.3 Adjustment of the Vertical Cross-hairp.1059.3.4 Collimation of the Instrumentp.1069.3.5 Checking / Adjusting the Optical Plummet Telescopep.1079.4 Adjustment of Compensation Systematic Error of Instrumentp.1089.5 Showing Constant List and Switch ON/OFF Compensation Systematic Error of Instrumentp.1109.6 How to adjust the date and timep.1119.7 How to Set the Instrument Constant Valuep.1129.8 Reference Frequency Checking Modep.1139.9 Inspection and Adjustment of Optic Axis for Auto -Trackingp.11410 SETTING THE PRISM CONSTANT VALUEp.11611 SETTING ATMOSPHERIC CORRECTIONp.11711.1 Calculation of Atmospheric Correctionp.11711.2 Setting of Atmospheric Correction Valuep.11712 CORRECTION FOR REFRACTION AND EARTH CURVATUREp.12212.1 Distance Calculation Formulap.12213 POWER SOURCE AND CHARGINGp.12313.1 Rechargeable Battery BT-56Qp.12314 DETACH/ATTACH OF TRIBRACHp.12515 BATTERY SYSTEMp.12616 PRISM SYSTEMp.12717 PRECAUTIONSp.12818 ERROR DISPLAYSp.12919 SPECIAL ACCESSORIESp.13020 SPECIFICATIONSp.133Backp.144
Page 1 of the Topcon GTS-822A user manual — INSTRUCTION MANUAL
Page 1 · click to enlarge
Page 1
Topcon GTS-822A — Top diagram (page 1)
Fig. 1 · Top

INSTRUCTION MANUAL

AUTO TRACKING TOTAL STATION GTS-820A SERIES

GTS-821A GTS-822A GTS-823A GTS-825A

Page 2 of the Topcon GTS-822A user manual — Top
Page 2 · click to enlarge
Page 2
Page 2 of the Topcon GTS-822A user manual — Top
Page 3 of the Topcon GTS-822A user manual — No responsibility
Page 3 · click to enlarge
Page 3

FOREWORD FOREWORD

Thank you for purchasing the TOPCON Auto Tracking Total Station, GTS-820A

series. For the best performance of the instruments, please carefully read these

instructions and keep them in a convenient location for future reference.

General Handling Precautions

Before starting work or operation, be sure to check that the instrument is functioning correctly with normal performance.

Do not submerge the instrument into water.

The instrument can not be submerged underwater. The instrument is designed based on the International Standard IP54, therefore it is protected from the normal rainfall.

Setting the instrument on a tripod

When mounting the instrument on a tripod, use a wooden tripod when possible. The vibrations that may occur when using a metallic tripod can effect the measuring precision.

Installing the tribrach

If the tribrach is installed incorrectly, the measuring precision could be effected. Occasionally check the adjusting screws on the tribrach. Make sure the base fixing lever is locked and the base fixing screws are tightened. TR-5 or TR-5P tribrach should be used for prism side when the traverse surveys is performed.

Guarding the instrument against shocks

When transporting the instrument, provide some protection to minimize risk of shocks. Heavy shocks may cause the measurement to be faulty.

Carrying the instrument

Always carry the instrument by its handgrip.

Exposing the instrument to extreme heat.

Do not leave the instrument in extreme heat for longer than necessary. It could adversely affect its performance.

Sudden changes of temperature

Any sudden change of temperature to the instrument or prism may result in a reduction of measuring distance range, i.e when taking the instrument out from a heated vehicle. Let instrument acclimate itself to ambient temperature.

Battery level check

Confirm battery level remaining before operating.

Memory back up

The instrument has a built in battery for memory back up. If the battery power is low, “Back up battery empty” will display. It is still possible to measure the distance and the angle, but the measured data and the parameter setting can be lost. Contact your dealer, to replace the battery.

Taking the battery out

It is recommended not to take the battery out during the power is on. All the data stored is possible gone at that time. So please do your assembling or taking the battery out after the power is off.

No responsibility

TOPCON Corporation has no responsibility for loss of data stored in the memory in case unexpected accidents.

Page 4 of the Topcon GTS-822A user manual — Storage in the case
Page 4 · click to enlarge
Page 4

FOREWORD

Rotating the instrument and telescope

Rotation of the instrument or telescope is driven electronically in normal operation. Do not disturb the rotation.

Storage in the case

Keep the telescope horizontally and turn the instrument to align its mark with the lower base mark (Storage mark). Keep its objective lens side downward. Storing it in the case in any other way may cause damage. Hold the hand grips and base with both hands, when taking the instrument out of the case, or putting the equipment in the case.

Maintenance for driving parts.

Every 4,000~5,000 hours operation in total, change grease of driving parts. Contact your dealer or TOPCON Head Office for the maintenance.

Page 5 of the Topcon GTS-822A user manual — WARNING
Page 5 · click to enlarge
Page 5

FOREWORD Display for Safe Use

In order to encourage the safe use of products and prevent any danger to the operator and others or damage to properties, important warnings are put on the products and inserted in the instruction manuals. We suggest that everyone understand the meaning of the following displays and icons before reading the “Safety Cautions” and text

DisplayMeaning WARNINGIgnoring or disregard of this display may lead to the danger of death or serious injury. CAUTIONIgnoring or disregard of this display may lead to personal injury or physical damage.
  • Injury refers to hurt, burn, electric shock, etc.
  • Physical damage refers to extensive damage to buildings or equipment and furniture. Safety Cautions

WARNING

  • There is a risk of fire, electric shock or physical harm if you attempt to disassemble or repair the instrument yourself.

This is only to be carried out by TOPCON or an authorized dealer, only!

  • Cause eye injury or blindness. Do not look at the sun through a telescope.
  • Laser beams can be dangerous, and can cause eye injury's if used incorrectly. Never attempt to repair the instrument yourself.
  • Cause eye injury or blindness. Do not stare into beam.
  • High temperature may cause fire. Do not cover the charger while it is charging.
  • High temperature may cause fire. Do not connect the battery to an instrument while it is charging.
  • Risk of fire or electric shock. Do not use damaged power cable, plug and socket.
  • Risk of fire or electric shock. Do not use a wet battery or charger.
  • May ignite explosively. Never use an instrument near flammable gas, liquid matter, and do not use in a coal mine.
  • Battery can cause explosion or injury. Do not dispose in fire or heat.
  • Risk of fire or electric shock. Do not use any power voltage except the one given on manufacturers instructions.
  • Battery can cause outbreak of fire. Do not use any other type of charger other than the one specified.
  • Risk of fire. Do not use any other power cable other than the one specified.
  • Battery can cause outbreak of fire. Do not block up the vent of the battery.
  • The short circuit of a battery can cause a fire. Do not short circuit battery when storing it.
Page 6 of the Topcon GTS-822A user manual — FOREWORD
Page 6 · click to enlarge
Page 6

FOREWORD

CAUTION

Use of controls or adjustment or performance of procedures other than those specified herein

may result in hazardous radiation exposure.

Let the laser beam reach the aimed object or the target without anybody else in the laser beam path. In case you operate laser beam open, avoid radiating laser beam to the height of man's head. It is quite possible for the beam to enter into one's eyes, and it is possible to lose visual sight temporarily, and lose one's caution and awareness of other dangers - avoid glaring beam.

Do not connect or disconnect equipment with wet hands, you are at risk of electric shocks if you do!

Risk of injury by overturn the carrying case. Do not stand or sit on the carrying cases.

Please note that the tips of tripod can be hazardous, be aware of this when setting up or carrying the tripod.

Risk of injury by falling down the instrument or case. Do not use a carrying case with a damaged which belts, grips or latches.

Do not allow skin or clothing to come into contact with acid from the batteries, if this does occur then wash off with copious amounts of water and seek medical advice.

A plumb bob can cause an injury to a person if used incorrectly.

It could be dangerous if the instrument falls over, please ensure you attach a handle battery to the instrument securely.

Ensure that you mount the Tribrach correctly, failing to do so may result in injury if the tribrach were to fall over.

It could be dangerous if the instrument falls over, please check that you fix the instrument to the tripod correctly.

Risk of injury by falling down a tripod and an instrument. Always check that the screws of tripod are tightened.

User 1)This product is for professional use only! The user is required to be a qualified surveyor or have a good knowledge of surveying, in order to understand the user and safety instructions, before operating, inspecting or adjusting. 2)Wear the required protectors (safety shoes, helmet, etc.) when operating.

Exceptions from Responsibility 1)The user of this product is expected to follow all operating instructions and make periodic checks of the product’s performance. 2)The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits. 3)The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster, (an earthquake, storms, floods etc.). A fire, accident, or an act of a third party and/or a usage any other usual conditions. 4)The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss of data, an interruption of business etc., caused by using the product or an unusable product. 5)The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage except for explained in the user manual. 6)The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement, or action due to connecting with other products.

Page 7 of the Topcon GTS-822A user manual — STARE INTO BEAM C A U T I O N
Page 7 · click to enlarge
Page 7

FOREWORD Laser Safety

GTS-820A series uses the visible laser beam for auto tracking, optical communication. The GTS-820A series products are manufactured and sold in accordance with “Radiation Safety of Laser Products, Equipment Classification, Requirements and User‘s Guide” (IEC Publication 60825-1) or “Performance Standards for Light-Emitting Products” (FDA/BRH 21 CFR 1040) provided on the safety standards for laser beam. As per the said standards, GTS-820A series is classified as “Class 2 (CLASS II) Laser Products”. The laser beam belongs not very dangerous type but we request you to keep and understand “Safety standard for users” as mentioned in the manual instruction. In case of any failure, do not disassemble the instrument. Contact TOPCON or your TOPCON dealer. Laser class of each mode is as follows.

Topcon GTS-822A — FOREWORD Laser Safety diagram (page 7)
Fig. 2 · FOREWORD Laser Safety

Labels

Find the labels which describes the caution and safety about the laser beam as follows in GTS-820A series. We request you to replace it one anytime the caution labels are damaged or lost and paste a new one at the same place. You can get the labels from Topcon or your dealer.

Topcon GTS-822A — Labels diagram (page 7)
Fig. 3 · Labels

STARE INTO BEAM C A U T I O N

Symbol marks while the laser is emitting.

The following symbol marks of instrument status will indicate that the laser is emitting.

Topcon GTS-822A — STARE INTO BEAM C A U T I O N diagram (page 7)
Fig. 4
Topcon GTS-822A — STARE INTO BEAM C A U T I O N diagram (page 7)
Fig. 5

The symbol mark

Page 8 of the Topcon GTS-822A user manual — Table of Contents
Page 8 · Contents
Contents

Contents

Topp.1FOREWORDp.3General Handling Precautionsp.3Display for Safe Usep.5Safety Cautionsp.5Userp.6Exceptions from Responsibilityp.6Laser Safetyp.7Contentsp.8Standard Set Compositionp.111 NOMENCLATURE AND FUNCTIONSp.121.1 Nomenclaturep.121.2 Displayp.141.3 Operating Keyp.151.4 Function Key (Soft Key)p.161.5 Star key (*key) modep.181.6 Auto Power Offp.221.7 Data Outputp.221.8 Rotating Methodp.221.8.1 Rotating by H/V Shuttle and H/V Jogp.221.8.2 Auto Inversionp.221.8.3 Rotating automatically to a required Horizontal and Vertical anglep.221.9 Using together with RC-2II Remote Control Systemp.231.10 Using connecting with Personal Computer (PC)p.242 PREPARATION FOR MEASUREMENTp.252.1 Power Connectionp.252.2 Setting Instrument Up For Measurementp.262.3 Power Switch Key ONp.272.4 Battery Level Indicatorp.282.5 Main Menu Iconsp.292.6 Vertical and Horizontal Angle Tilt Correctionp.302.7 Compensation of Systematic Error of Instrumentp.312.8 Resume Mode ON/OFFp.322.9 How to Enter Numerals and Alphabet Lettersp.322.10 Memory Cardp.332.11 Inclination of Prism and Measuring Errorp.343 AUTOMATIC TRACKING / AUTOMATIC COLLIMATIONp.363.1 Automatic Trackingp.363.2 Automatic Collimationp.383.3 Range of Laser for Auto-tracking and Auto-collimatingp.393.4 Setting Parameters for Auto-Trackingp.403.4.1 Setting Itemsp.403.4.2 How to set the parametersp.424 STANDARD MEASUREMENT MODEp.434.1 Angle Measurementp.434.1.1 Measuring Horizontal Angle Right and Vertical Anglep.434.1.2 Switching Horizontal Angle Right/Leftp.444.1.3 Measuring from the Required Horizontal Anglep.444.1.4 Vertical Angle Percent Grade(%) Modep.454.1.5 Automatic Rotation to a Required Horizontal and Vertical Absolute Anglep.464.2 Distance Measurementp.474.2.1 Setting of the Atmospheric Correctionp.474.2.2 Setting of the Correction for Prism Constantp.474.2.3 Distance Measurement (Continuous Measurement)p.474.2.4 Distance Measurement (Single/N-times Measurement)p.484.2.5 Fine / Coarse Measuring Modep.504.2.6 Stake Out (S-O)p.514.3 COORDINATE MEASUREMENTp.524.3.1 Setting Coordinate Values of Occupied Pointp.524.3.2 Setting of the Instrument Height / Prism Heightp.544.3.3 Execution of Coordinate Measuringp.554.4 DATA OUTPUTp.575 PROGRAM MODESp.595.1 Setting a Direction Angle for Backsight Orientationp.605.2 Retaining a Coordinate (STORENEZ)p.615.3 Remote Elevation measurement (REM)p.635.4 Missing Line Measurement (MLM)p.665.5 Line Measurement (LINE)p.695.6 Offset measurement (OFFSET)p.725.6.1 Angle Offsetp.735.6.2 Distance Offset Measurementp.755.6.3 Plane Offset Measurementp.775.6.4 Column Offset Measurementp.795.7 External Linkp.815.7.1 Starting compatible communication program of AP-L1Ap.815.7.2 Setting for the communicationp.815.7.3 Carrying out Communicationp.856 MEMORY MANAGE MODESp.866.1 View Internal Memory and Card Memory Statusp.866.2 Protect a Filep.876.3 Rename a Filep.876.4 Deleting a Filep.886.5 Copy a Filep.886.6 Initializing Memoryp.897 COMMUNICATION MODESp.907.1 Setting of PROTOCOLp.907.2 Data File Inp.917.3 Data File Outp.918 PARAMETERS SETTING MODEp.928.1 Parameter Setting Optionsp.928.1.1 Parameters for Measurement and Displayp.928.1.2 Parameters for communicationp.948.2 Setting Parametersp.968.2.1 Parameters for Measurement and Displayp.968.2.2 Parameters for Communicationp.978.2.3 Password Optionp.979 CHECK AND ADJUSTMENTp.1009.1 Checking and Adjusting of Instrument Constantp.1009.2 Checking the Optical Axisp.1019.3 Checking/Adjusting the Theodolite Functionsp.1039.3.1 Checking /Adjusting the Plate Levelp.1049.3.2 Checking /Adjusting the Circular Levelp.1049.3.3 Adjustment of the Vertical Cross-hairp.1059.3.4 Collimation of the Instrumentp.1069.3.5 Checking / Adjusting the Optical Plummet Telescopep.1079.4 Adjustment of Compensation Systematic Error of Instrumentp.1089.5 Showing Constant List and Switch ON/OFF Compensation Systematic Error of Instrumentp.1109.6 How to adjust the date and timep.1119.7 How to Set the Instrument Constant Valuep.1129.8 Reference Frequency Checking Modep.1139.9 Inspection and Adjustment of Optic Axis for Auto -Trackingp.11410 SETTING THE PRISM CONSTANT VALUEp.11611 SETTING ATMOSPHERIC CORRECTIONp.11711.1 Calculation of Atmospheric Correctionp.11711.2 Setting of Atmospheric Correction Valuep.11712 CORRECTION FOR REFRACTION AND EARTH CURVATUREp.12212.1 Distance Calculation Formulap.12213 POWER SOURCE AND CHARGINGp.12313.1 Rechargeable Battery BT-56Qp.12314 DETACH/ATTACH OF TRIBRACHp.12515 BATTERY SYSTEMp.12616 PRISM SYSTEMp.12717 PRECAUTIONSp.12818 ERROR DISPLAYSp.12919 SPECIAL ACCESSORIESp.13020 SPECIFICATIONSp.133Backp.144
Page 11 of the Topcon GTS-822A user manual — FOREWORD Standard Set Composition
Page 11 · click to enlarge
Page 11

FOREWORD Standard Set Composition

The numerical value in parentheses shows the quantity.

GTS-820A series (with lens cap) (1)Plastic carrying case (1) Battery BT-56Q (2)Battery charger BC-27BR or BC-27CR (1) Sun shade (1)Plastic rain cover (1) Plumb bob set (1) Plumb bob hook is included in the tool kit case.Tool kit with case [ rod pins, Plumb bob hook, screwdriver, cleaning brush ] (1) Instruction manual (1)
Topcon GTS-822A — FOREWORD Standard Set Composition diagram (page 11)
Fig. 6 · FOREWORD Standard Set Composition

(Make sure that all of the above items are with the instrument when purchased.)

Remarks: 1) Battery charger BC-27CR is for AC 230V use and BC-27BR is for AC 120V use. 2) Plumb bob set and plumb bob hook are supplied for certain markets.

Page 12 of the Topcon GTS-822A user manual — 1.1 Nomenclature
Page 12 · click to enlarge
Page 12

1 NOMENCLATURE AND FUNCTIONS 1 NOMENCLATURE AND FUNCTIONS

1.1 Nomenclature

Topcon GTS-822A — 1.1 Nomenclature diagram (page 12)
Fig. 7 · 1.1 Nomenclature

The caution labels are pasted up GTS-820A series which describe the warning of laser beam. Refer to "Laser Safety" about label positions and their shapes.

Page 13 of the Topcon GTS-822A user manual — 1 NOMENCLATURE AND FUNCTIONS
Page 13 · click to enlarge
Page 13

1 NOMENCLATURE AND FUNCTIONS

Topcon GTS-822A — 1 NOMENCLATURE AND FUNCTIONS diagram (page 13)
Fig. 8
Page 14 of the Topcon GTS-822A user manual — SD HD NEZ 0SET HOLD P1 ↓
Page 14 · click to enlarge
Page 14

1 NOMENCLATURE AND FUNCTIONS

1.2 Display

  • Display In general upper fo ur lines display the measuring data, and the bottom line displays the soft key function which is changed by the measuring mode.
  • Contrast The contrast and illumination of display window are adjusted by star ( H ) key.
  • Heater (Automatic) The built-in heater keeps the display functional when the temperature goes below 0°C (32 °F). To switch the heater ON or OFF, refer to Chapter 8 “PARAMETERS SETTING MODE”. When the heater is ON and the temperature goes below 0°C.(32 °F), the heater automatically adjust the temperature to the display to keep it operating.
  • Example

V : 87°55'45" HR: 180°44'12"

V : 87°55'40" HR: 180°44'12" PSM 0.0 SD: 12.345 PPM 0.0 (m) *F.R MEAS MODE VH HD NEZ P1↓

SD HD NEZ 0SET HOLD P1 ↓

V-angle87°55’20” H-angle : 180°44’12”
Horizontal-angle87°55’40” Horizontal distance : 180°44’12” Relative elevation :12.345m
  • Display marks

Display Contents Display Content

V V-angle * EDM working

V% Percent grade (m) Meter unit

HR H-angle right (f) Feet unit

HL H-angle left F Fine mode

HD Horizontal distance C Coarse mode (1mm)

VD Relative elevation T Tracking mode (10mm)

SD Slope distance R Repeat measurement

N N coordinate S Single measurement

E E coordinate N N-times measurement

Z Z coordinate ppm Atmospheric correction value

psm Prism constant value

Battery Level Indicator Refer to Section 2.4 “Battery Level Indicator” for further information.

Rotation Indicator Refer to Section 1.8 “Rotating Method” for further information.

Angle measurement mode · Distance measurement mode

Page 15 of the Topcon GTS-822A user manual — KEY NAME FUNCTION
Page 15 · click to enlarge
Page 15

1 NOMENCLATURE AND FUNCTIONS

l The symbol marks for Auto-tracking and Auto-collimating

Auto-collimating (Laser is emitting) GTS-820A series is in auto- collimating status.

Auto-tracking (Laser is emitting) GTS-820A series is in auto- tracking status.

Waiting (Laser is emitting) GTS-820A series is in waiting status.

Searching (Laser is emitting) GTS-820A series is searching a prism.

Failure in auto-collimating. (Laser is off) GTS-820A series could not find the target prism during auto- collimating.

1.3 Operating Key

Topcon GTS-822A — 1.3 Operating Key diagram (page 15)
Fig. 9 · 1.3 Operating Key

KEY NAME FUNCTION

F1~F6 Soft key Functions are according to the displayed message.

0~9 . - Numeric key Numeric Character Entry for Preset Data

A ~/ Alpha key Alpha Character Entry

ESC Escape key Escape to Previous Display or Menu

* Star key Optional instrument functions

ENT Enter key End operation of data input and accepts data

POWER Power key ON/OFF of power source. (Power key is located on the side of the instrument.)

Page 16 of the Topcon GTS-822A user manual — V : 87°55'45"5 HR: 180°44'12"5 SD HD NEZ 0SET HOLD P1 ↓
Page 16 · click to enlarge
Page 16

1 NOMENCLATURE AND FUNCTIONS

1.4 Function Key (Soft Key)

The Soft Key Functions are labeled on the bottom of display. Soft Key functions are different for each measurement.

Topcon GTS-822A — 1 NOMENCLATURE AND FUNCTIONS diagram (page 16)
Fig. 10

V : 87°55'45"5 HR: 180°44'12"5 SD HD NEZ 0SET HOLD P1 ↓

V : 87°55'45"5 HR: 180°44'12"5 SD HD NEZ 0SET HOLD P1 ↓

V : 90°10'20"5 HR: 120°30'40"5 PSM 0.0 SD: PPM 0.0 (m) F.R MEAS MODE VH HD NEZ P1↓

V : 90 10'20"5 HR: 120 30'40"5 PSM 0.0 HD: PPM 0.0 VD: (m) F.R MEAS MODE VH SD NEZ P1↓

N : 12345.6789 E : -12345.6789 PSM 0.0 Z : 10.1234 PPM 0.0 (m) F.R MEAS MODE VH SD HD P1↓

Topcon GTS-822A — V : 87°55'45"5 HR: 180°44'12"5 SD HD NEZ 0SET HOLD P1 ↓ diagram (page 16)
Fig. 11

SD F1 Slope distance measuring mode. HD F2 Horizontal distance measuring mode. NEZ F3 Coordinate distance measuring mode. 0SET F4 Set horizontal angle to 0°00'00". HOLD F5 Horizontal angle hold. TURN F1 Turns the instrument to required angle automatically. HSET F2 Preset a horizontal angle. R/L F3 Changes horizontal angle right or left. V/% F4 Changes the display to vertical angle or percent of grade.

TILT F5 Sets the tilt function, ON/OFF. If ON, the display shows tilt correction value.

Page 17 of the Topcon GTS-822A user manual — 1 NOMENCLATURE AND FUNCTIONS
Page 17 · click to enlarge
Page 17

1 NOMENCLATURE AND FUNCTIONS

MEAS F1 Starts slope distance measurement mode. Changes Continuous/ N-times (single) measurement mode. MODE F2 Changes Fine / Coarse(1mm) /Coarse(10mm) mode. VH F3 Angle measurement mode.

HD F4 Horizontal distance measurement mode. Displays the horizontal distance data after N-times or single measurement.

NEZ F5 Coordinate measurement mode. Displays the coordinate after N-times or single measurement. TURN F1 Turns the instrument to required angle automatically. SO F2 Stake out measurement mode. MEAN F3 Sets the number of N-time measurement. m/ft F4 Changes distance measurement unit to meter or feet.

MEAS F1 Starts horizontal distance measurement mode. Changes continuous/ N-times (single) measurement mode. MODE F2 Changes Fine / Coarse(1mm) /Coarse(10mm) mode. VH F3 Angle measurement mode.

SD F4 Slope distance measuring mode. Display the slope distance after N-times or single measurement.

NEZ F5 Coordinate measurement mode. Displays the coordinate after N-times or single measurement. TURN F1 Turns the instrument to required angle automatically. SO F2 Stake out measurement mode. MEAN F3 Sets the number of N-time measurement. m/ft F4 Switches meter or feet unit.

MEAS F1 Starts coordinate measurement mode. Changes continuous/ N-times (single) measurement mode. MODE F2 Changes Fine / Coarse(1mm) /Coarse(10mm) mode. VH F3 Angle measurement mode.

SD F4 Slope distance measuring mode. Display the slope distance after N-times or single measurement.

HD F5 Horizontal distance measurement mode. Displays the horizontal distance data after N-times or single measurement.

TURN F1 Turns the instrument to required angle automatically. HT F2 Input Instrument / prism height values. MEAN F3 Sets the number of N-time measurement. m/ft F4 Switches meter or feet unit. SET F5 Pre-set instrument coordinate values.

Show 7 more labels / short text on this page
Page Display Soft · key Function · Slope distance measuring · Horizontal · distance measuring · Coordinate · measuring
Page 18 of the Topcon GTS-822A user manual — 1 NOMENCLATURE AND FUNCTIONS
Page 18 · click to enlarge
Page 18

1 NOMENCLATURE AND FUNCTIONS

1.5 Star key ( * key) mode

Press the (H) key to view the instrument options. Since there are three screens of options, press [F6](1↓) soft key to view the next screen. The following instrument options can be selected from the (H):

  • Screen One 1) View Date & Time 2) Auto-tracking [F1] 3) Auto-collimating [F2] 4) Set the parameters for Auto-tracking.[F3] 5) Autoinversion [F4] 6) Electric circular graphic display[F5]
  • Screen Two 7) Adjustment the contrast of the display [F1 & F2] 8) Turn the back light of the display ON/OFF [F3] 9) Reticle illumination---Off / Low / Medium / High [F4] 10) View free memory for internal and card memory [F5]
  • Screen Three 11) The light acceptance quantity level (signal level) is displayed.[F1] 12) Set the Temperature, Pressure, Atmospheric Correction Value (ppm), and Prism Constant Value (PSM) [F2] 13) Turn the Tracking Indicator option ON/OFF [F3]
Topcon GTS-822A — 1 NOMENCLATURE AND FUNCTIONS diagram (page 18)
Fig. 12

Set the Temperature, Pressure, Atmospheric Correction Value (PPM), and Prism Constant Value (PSM) Displaying Signal Level

Page 19 of the Topcon GTS-822A user manual — 1 NOMENCLATURE AND FUNCTIONS
Page 19 · click to enlarge
Page 19

1 NOMENCLATURE AND FUNCTIONS

1. View Date & Time The date and time can be viewed on both screens. To change the displayed order of the date, (Date/ Month/Year), (Month / Date / Year) or (Year/Month/Date), see Chapter 8 “PARAMETERS SETTING MODE” . To set the date and time, see Chapter 9 “CHECK AND ADJUSTMENT”.
2. Turn the auto-tracking ON/OFF Press the [F1] key to start auto-tracking. See Section 3.1 “Automatic Tracking” .
3. Turn the auto-collimating ON/OFF Press the [F2] key to start auto-collimating. See Section 3.2 “Automatic Collimation” .
4. Set the parameters for the auto-tracking A proper setting for each parameter such as tracking pattern, tracking range, waiting time, tracking speed and tracking sensitivity. See Section 3.4 “Setting Parameters for Auto-Tracking” .
5. Auto Inversion Pressing the [F4] key causes the instrument to reverse and turn the telescope and instrument automatically. l To stop auto rotating in case of emergency, press any keys except POWER key. l During auto rotation, do not disturb the instrument.(Stopping the rotation with a touch of the hand). Such action may cause trouble or harm to instrument or operator.
6. Electric circular level graphic display Electric circular level can be displayed by graphic. This function is good for level the instrument when the circular level is difficult to see directly. Press the [F5] key to display the graphic. In the displays of reverse side, the graphic bubble moves in reverse.
Topcon GTS-822A — 1 NOMENCLATURE AND FUNCTIONS diagram (page 19)
Fig. 13

Rotate the leveling screws while observing the display. After leveling, press [F1]. The display changes to the previous mode.

7. Adjustment the contrast of the display This enable you to adjust the contrast of the display. Press the [F6] key to get to Screen 2 on the display. Press the [F1] or [F2] key to brighten or dim the display.
8. Turn the display back light ON/OFF When the back light is OFF, the light bulb icon is dark. Press the [F6] key to get to Screen 2 on the display. To turn the back light ON, press the [F3] key. Press [F3] again to turn the back light OFF.
Topcon GTS-822A — 1 NOMENCLATURE AND FUNCTIONS diagram (page 19)
Fig. 14
Page 20 of the Topcon GTS-822A user manual — 1 NOMENCLATURE AND FUNCTIONS
Page 20 · click to enlarge
Page 20

1 NOMENCLATURE AND FUNCTIONS

9. Reticle illumination (OFF/Low/Middle/High) Press the [F6] key to get to Screen 2 on the display. Press the [F4] key to turn the reticle illumination ON. Continuing to press [F4] will change the intensity options.
Topcon GTS-822A — 1 NOMENCLATURE AND FUNCTIONS diagram (page 20)
Fig. 15
10. View free memory The amount of free memory for the card or internal memory can be displayed. Press the [F6] key to get to Screen 2 on the display. Press the [F5] key to view free memory. The card memory icon (top left side of the display) shows the size of the card and the amount of free memory. The second icon shows the amount of free internal memory.
Topcon GTS-822A — 1 NOMENCLATURE AND FUNCTIONS diagram (page 20)
Fig. 16

See Chapter 6 “MEMORY MANAGE MODES”, for further options and instructions.

11. Set audio mode The light acceptance quantity level (Signal level) is displayed in this mode. When reflected light from the prism is received, a buzzer sounds. This function is good for easy collimation when the target is difficult to find. Press the [F1] key on screen 3. The received return signal level is displayed with bar graph as follows.
Topcon GTS-822A — 1 NOMENCLATURE AND FUNCTIONS diagram (page 20)
Fig. 17

No light acceptance Minimum quantity level Maximum quantity level

(1) To stop the buzzer, see Chapter 8 “PARAMETERS SETTING MODE”. (2) Also, it is possible to display the signal level in Distance Measuring Mode.

12. Setting Temperature, Pressure, Atmospheric correction value (ppm), Prism constant value (PSM) The temperature, pressure, PPM, and PSM can be viewed by pressing the [F2] key on screen 3 . The received return signal level is displayed with bar graph as follows. Refer to Chapter 10 “SETTING THE PRISM CONSTANT VALUE” and Chapter 11 “SETTING ATMOSPHERIC CORRECTION”, for further instructions.
Page 21 of the Topcon GTS-822A user manual — OFF ON
Page 21 · click to enlarge
Page 21

1 NOMENCLATURE AND FUNCTIONS

13. Tracking Indicator A man who is staying on line with the direction of GTS-820A series or automatic tracking status by emitted LED light (orange color) from GTS-820A series.
  • Operation Pressing [F3] key on screen three functions Tracking Indicator. The tracking indicator status will be changed according to the type of auto tracking mode and its conditions. A man from the prism side can recognize the status of instrument. When angle measuring value turns stable during tracking still object, the tracking indicator changes from quick continuous flashing to quick intermittent flashing. So you can decide from the sign of flashing for recording data timing at one person surveying.

OFF ON

Meaning of Tracking Indicator ON or Flashing

Topcon GTS-822A — OFF ON diagram (page 21)
Fig. 18

Quick continuous flashing In case angle measuring value is instable during auto tracking mode.

Quick intermittent flashing In case angle measuring value is stable during auto tracking mode.

Topcon GTS-822A — OFF ON diagram (page 21)
Fig. 19

l The function of the Tracking Indicator will be used as a guide to know the status of GTS-820A series from the prism side. This is not a function to determine precise collimating for measuring. l The quality of its results will depend on the weather conditions and the use's eyesight. l Sometimes happens difficulty of seeing the tracking indicator because too much bright of the beam for tracking. l Using Tracking Indicator mode will result shorter in reduced time out of the battery.

Page 22 of the Topcon GTS-822A user manual — 1.8 Rotating Method
Page 22 · click to enlarge
Page 22

1 NOMENCLATURE AND FUNCTIONS

1.6 Auto Power Off

The Auto Power OFF feature can be set from 1 to 99 minutes. If no keys are pressed within the set time, the Auto Power OFF will automatically turn the instrument OFF in order to save the battery time. See Chapter 8 “PARAMETERS SETTING MODE”, for further instructions.

1.7 Data Output

When GTS-820A series receives data output command from an external connected device, the measured data will be output by GTS-820A series. Select from the following 2 ways for the output. (For setting, see Chapter 8 “PARAMETERS SETTING MODE” .)

REC-A : The measurement is started and new data is output. REC-B : The data being displayed is output.

1.8 Rotating Method

1.8.1 Rotating by H/V Shuttle and H/V Jog H/V shuttle or H/V jog can be used to rotate the instrument manually. The shuttle movement or displacement is proportional in speed and size of angle desired. A small, slow turn of the shuttle will result in a slow small angle displaced. Likewise, a larger abrupt turn of the shuttle will result in a coarse angle displacement. H/V jog can be used for accurate collimating of the target much like a standard tangent screw.

1.8.2 Auto Inversion Pressing the [F4] key in Star Key mode causes the instrument to reverse and turn the telescope and instrument automatically. l To stop auto rotating by auto inversion key in case of emergency, press any keys except POWER key. l During auto rotation, don't disturb the instrument.(Stopping the rotation with a touch of the hand). Such action may cause trouble or harm to instrument or operator. See Section 1.5 “Star key (*key) mode” for further instructions.

1.8.3 Rotating automatically to a required Horizontal and Vertical angle In Standard Measurement Modes, the instrument can be rotated automatically by input a required horizontal and/or vertical angle. For further instructions, see Section 4.1.5 “Automatic Rotation to a Required Horizontal and Vertical Absolute Angle” .

This mark will appear while the instrument is rotating automatically. V : 87°55'45"5 HR: 180°44'12"5 SD HD NEZ 0SET HOLD P1↓

Page 23 of the Topcon GTS-822A user manual — RC-2RII
Page 23 · click to enlarge
Page 23

1 NOMENCLATURE AND FUNCTIONS

1.9 Using together with RC-2II Remote Control System

Using together with RC-2II Remote Control System makes it possible to optical communicate between the instrument and remote controller RC-2RII, the prism side. This gives easy operation by one man surveying in applying programs. Also connecting data collector to remote controller, you can manage communication reciprocally between the instrument and direct to data collector.

Turn-round function

You can turn the GTS-820A series round to the remote controller RC-2RII side easily by [Turn-round] key of the remote controller RC-2RII. This function helps to increase one man surveying efficiency.

RC-2RII

See to Section 5.7 “External Link” and Chapter 8 “PARAMETERS SETTING MODE” for further information. l Set the transmit path to " RC". l Set the transmit channel same as RC-2RII side. l To execute transmission, set the remote in Programs mode to [Remote].

Page 24 of the Topcon GTS-822A user manual — 1 NOMENCLATURE AND FUNCTIONS
Page 24 · click to enlarge
Page 24

1 NOMENCLATURE AND FUNCTIONS

1.10 Using connecting with Personal Computer (PC)

The auto-tracking function or auto collimating function makes easy remote control of the instrument from PC. The followings are the main communication commands and explanations. How to communicate or more informations of communication command, you can see the interface manual which provided optionally.

Commands Action of GTS-820A series

Transmit command for measured data Each measured data will be out put according to the command type.

Transmit command for tracking mode The status of Automatic Tracking mode will be out put.

Transmit command for battery level The battery level will be out put.

Transmit command for coordinate of instrument point

Setting coordinate of instrument point will be out put.

Each setting tracking parameter of instrument will be out put according to the command type.

Transmit command for tracking parameter

Each selecting mode in horizontal angle or angle measurement can be decided according to the purpose of command.

Setting of angle measurement

Setting of distance measurement Setting the measurement mode for distance measurement.

Setting coordinate of instrument point Setting the coordinate of instrument point.

Setting the tracking parameter Setting each tracking parameter according to the command.

T.I. ON / OFF ON / OFF of Tracking indicator.

Rotating command Rotating of setting angle.

Inversion Inversion movement.

Setting tracking mode Setting from automatic tracking mode to each command mode.

Transmit command · Mode setting · Action

Page 25 of the Topcon GTS-822A user manual — (unnecessary if on-board Ni-MH battery BT-56Q is used)
Page 25 · click to enlarge
Page 25

2 PREPARATION FOR MEASUREMENT 2 PREPARATION FOR MEASUREMENT

2.1 Power Connection

(unnecessary if on-board Ni-MH battery BT-56Q is used)

See below for connecting the external battery pack. l Battery pack BT-3Q Power cord , PC-5 is used. l Large capacity battery pack BT-3L Power cord PC-6 is used.

l When using a external battery, the rechargeable battery BT-56Q should be attached (The instrument will lack in balance if the internal battery BT-56Q is removed.)

The external battery and the internal battery can be used at the same time. The GTS-820A series will select a battery due to the battery remaining automatically.

Topcon GTS-822A — (unnecessary if on-board Ni-MH battery BT-56Q is used) diagram (page 25)
Fig. 20 · (unnecessary if on-board Ni-MH battery BT-56Q is use…

AC-6 External 12V Battery

Page 26 of the Topcon GTS-822A user manual — Reference: Leveling and Centering the Instrument
Page 26 · click to enlarge
Page 26

2 PREPARATION FOR MEASUREMENT

2.2 Setting Instrument Up For Measurement

Mount the instrument to the tripod. Level and center the instrument precisely to insure the best performance. Use tripods with a tripod screw of 5/8 in. diameter and 11 threads per inch, such as the Type E TOPCON wide- frame wooden tripod.

Reference: Leveling and Centering the Instrument

1. Setting up the Tripod First, extend the extension legs to suitable lengths and tighten the screws on their midsections. 2. Attaching the Instrument on the Tripod Head Place the instrument carefully on the tripod head and slide the instrument by loosening the tripod screw. If the plumb bob is positioned right over the center of the point, slightly tighten the tripod screw. 3. Roughly Leveling the Instrument by Using the Circular Level 1 Turn the leveling screws A and B to move the bubble in the circular level. The bubble is now located on a line perpendicular to a line running through the centers of the two leveling screws being adjusted.

2 Rotate the instrument 90° (100g) around its vertical axis and turn the remaining leveling screw or C to center the bubble once more.

3 Repeat the procedures 1 and 2 for each 90° (100g) rotation of the instrument and check whether the bubble is correctly centered for all four points.

5. Centering by Using the Optical Plummet Telescope Adjust the eyepiece of the optical plummet telescope to your eyesight. Slide the instrument by loosening the tripod screw, place the point on the center mark, and then tighten the tripod screw. Sliding the instrument carefully not to rotate that allows you to get the least dislocation of the bubble.

2 Turn the leveling screw C to bring the bubble to the center of the circular level. 4. Centering by Using the Plate Level 1 Rotate the instrument horizontally by using the Horizontal motion/clamp screw and place the plate level parallel with the line connecting leveling screws A and B, and then bring the bubble to the center of the plate level by turning leveling screws A and B.

6. Completely Leveling the Instrument Leveling the instrument precisely in a similar way to 4. Rotate the instrument and check to see that the bubble is in the center of the plate level regardless of telescope direction, then tighten the tripod screw hard.

Leveling screw A Leveling screw B

Show 6 more labels / short text on this page
Leveling screw C · Leveling screw C · Leveling screw A · Leveling screw B · Point · Center mark
Page 27 of the Topcon GTS-822A user manual — 2 PREPARATION FOR MEASUREMENT
Page 27 · click to enlarge
Page 27

2 PREPARATION FOR MEASUREMENT

2.3 Power Switch Key ON

Topcon GTS-822A — 2 PREPARATION FOR MEASUREMENT diagram (page 27)
Fig. 21
3. Type your password. Self checking mode will display.

Level the instrument by turning the leveling screws. When the leveling is within ±30" and stable, the self checking will start.

The instrument will turn automatically and the tilt sensor offset value will be measured and memorized.

After checking, the main menu icons will be shown.

l Self checking option The self checking function is to check internal communication and tilt sensor offset value. When ambient temperature is changed or the instrument is not balanced by its internal battery is attached or detached, the self checking is recommended. l Password option Setting a password (Maximum 10 digits number) and activating ON of password option can be helpful to avoid miss operation by unauthorized operator. Setting password option is necessary to use this function. To set password option, see Chapter 8 “PARAMETERS SETTING MODE” . l Choosing the first mode when turning on the instrument You can choose the first mode from the following modes when turning on the instrument. 1. Main Menu 2. Standard Measurement Mode 3. External Link See Chapter 8 “PARAMETERS SETTING MODE” . l ON/OFF of a self check function can also be chosen. See Chapter 8 “PARAMETERS SETTING MODE” . l Confirm the battery power remaining on the display. Replace with charged battery or charge when battery level is low. Refer to Section 2.4 “Battery Level Indicator” .

Page 28 of the Topcon GTS-822A user manual — 2 PREPARATION FOR MEASUREMENT 2.4 Battery Level Indicator
Page 28 · click to enlarge
Page 28

2 PREPARATION FOR MEASUREMENT 2.4 Battery Level Indicator

The battery power indicator shows the level of battery strength.

Indicates Battery Power Remaining

2003-10-10 15:30:40

Measurement is possible.

Prog Std Mem Comm Adj Para

The power is poor. The battery should be recharged or replace the battery. (Angle measurent can only be possible, the auto-collimating, auto-tracking and distance maesurenat can not be possible.)

Measurement is impossible. Need to recharge or replace the battery.

* Battery power remaining display is omitted in this manual.

Note: 1) The battery operating time will vary depending on the environmental conditions, such as ambient temperature, charging time, and the number of times charging and discharging the battery. 2) In low temperature (especially while the heater of display is working), the battery operating time will shorten to one-half of normal temperature use. 3) The indicator for battery power remaining shows the power level during each measurement mode. The condition indicated for the battery power remaining in the angle measurement mode may not be adequate to measure a distance. Changing from angle mode to distance mode during a poor battery condition may cause the EDM not to measure a distance. We recommend that you check the battery condition before going into the field. 4) Also note, when changing from one measurement mode to another, the battery indicator may not show a decrease or an increase immediately. The battery indicator system was designed to show the general condition for the battery strength. It does not respond instantly. 5) For more information on battery usage, refer to Chapter 13 “POWER SOURCE AND CHARGING” .

Blinking

Page 29 of the Topcon GTS-822A user manual — 2 PREPARATION FOR MEASUREMENT
Page 29 · click to enlarge
Page 29

2 PREPARATION FOR MEASUREMENT

2.5 Main Menu Icons

The main menu icons are as follows. Select the menu by pressing soft keys ([F1]~[F6]).

2003-07-10 15:30:40

Prog Std Mem Comm Adj Para

PARAMETERS SETTING MODES The PARAMETERS SETTING MODES are stored in memory once the instrument is OFF. (See Chapter 8 “PARAMETERS SETTING MODE”.)

ADJUSTMENT MODES Used for checking and adjustment. l Systematic errors adjustment for compensation. l Show compensation values of systematic errors of instrument l Set Date & Time l Set instrument constant value l Reference frequency of EDM l Optic Axis for Auto-tracking (See Chapter 9 “CHECK AND ADJUSTMENT”.)

COMMUNICATION MODES l Set communication with external instrument l Input/Output a data file l Load application program. (See Chapter 7 “COMMUNICATION MODES”.)

MEMORY MANAGE MODES l Display memory status l Protect/Eras/Rename/Copy Files, l Initialize a card or internal memory. (See Chapter 6 “MEMORY MANAGE MODES” .)

STANDARD MEASUREMENT MODES l Angle measurement l Distance measurement l Coordinate measurement (See Chapter 4 “STANDARD MEASUREMENT MODE” .)

PROGRAM MODES ( APPLICATION MEASUREMENT) l Set a direction angle for horizontal orientation l Retain Coordinate (STORE-NEZ) l Remote elevation measurement l Missing line measurement l Line measurement l External link l Off set measurement (See Chapter 5 “PROGRAM MODES” .)

Page 30 of the Topcon GTS-822A user manual — 2 PREPARATION FOR MEASUREMENT
Page 30 · click to enlarge
Page 30

2 PREPARATION FOR MEASUREMENT

2.6 Vertical and Horizontal Angle Tilt Correction

When the tilt sensors are activated, automatic correction of vertical and horizontal angle for mislevelment is displayed. To ensure a precise angle measurement, tilt sensors must be turned on. The display can also be used to fine level the instrument. If the (TILT OVER) display appears the instrument is out of automatic compensation range and must be leveled manually.

Topcon GTS-822A — 2 PREPARATION FOR MEASUREMENT diagram (page 30)
Fig. 22

Inclination of the standing axis in the Y direction

Inclination of the standing axis in the X direction

l GTS-820A series compensates both the vertical angle and the horizontal angle readings due to inclination of the standing axis in the X and Y directions. l For more information about dual axis compensation, see Chapter “APPENDIX” “Dual Axis Compensation”.

Topcon GTS-822A — 2 PREPARATION FOR MEASUREMENT diagram (page 30)
Fig. 23

Rotate the leveling screws and level the instrument. After leveling (when each axis is within ±1'30"), the display returns to the previous mode automatically.

l The display of Vertical or Horizontal angle is unstable when instrument is on an unstable stage or a windy day. You can turn off the auto tilt correction function of V/H angle in this case. To set TILT correction mode ON/OFF, refer to next page or Chapter 8 “PARAMETERS SETTING MODE”.

Page 31 of the Topcon GTS-822A user manual — 2.7 Compensation of Systematic Error of Instrument
Page 31 · click to enlarge
Page 31

2 PREPARATION FOR MEASUREMENT

l Setting Tilt Correction by Soft Key Enable you to select tilt ON/OFF function on page 2. The setting performed here will be memorized after powering OFF. [Example] Setting X,Y Tilt ON

Operating procedure Option Display

1 Press [F6] key to get the function page 2.

V : 87°55'45" HR: 180°44'12"

SD HD NEZ 0SET HOLD P1↓ REC HSET R/L V/% TILT P2↓

2 Press [F5](TILT) key. Current setting is displayed. *1

TILT ON (V)

ON-1 ON-2 OFF ESC

3 Press [F2](ON-2) key. The display shows tilt correction value.

X:+0°00'00" Y:+0°00'00"

4 Press [F1] key. The display returns previous mode.

*1) Pressing [F6](ESC) key, the display returns previous mode. l The tilt sensor setting will be stored in memory when the instrument is turned OFF. The tilt sensor option can also be changed in the Parameter Setting Modes. When you change the tilt sensor option in the angle measurement mode, it will change in the Parameter Setting Modes and visa verse.

2.7 Compensation of Systematic Error of Instrument

1. Error of vertical axis (X,Y tilt sensor offset) 2) Collimation error 3) Error of vertical angle 0 datum 4) Error of horizontal axis The above mentioned errors can be compensated by software, which calculated internally according to each compensation value. Also these errors can be compensated by software collimating one side of the telescope that is carried out to delete the error by turning in normal and reverse both sides of telescope so far.

l To adjust or reset the above compensation value, see Chapter 9 “CHECK AND ADJUSTMENT” . l Enable you to stop this function, see Chapter 8 “PARAMETERS SETTING MODE” or Chapter 9 “CHECK AND ADJUSTMENT” .

Page 32 of the Topcon GTS-822A user manual — 2.9 How to Enter Numerals and Alphabet Letters
Page 32 · click to enlarge
Page 32

2 PREPARATION FOR MEASUREMENT

2.8 Resume Mode ON/OFF

The Resume mode will memorize the last display or mode when the power is turned OFF. When the power is turned back ON, the last display or mode will be shown. The Resume mode option only appears when the power is OFF.

Power switch key OFF

Power off Resume mode OFF ON ESC

Pressing [F1](OFF) key or [F2](ON) key, select the resume mode. [F1] [F2]

2.9 How to Enter Numerals and Alphabet Letters

Alpha and numeric character key entry is simple and quick from the key board. [Example] Renaming a file in the Memory Manager Modes.

Operating procedure Option Display

Rename Old name [TOPCON .DAT] New name [ ]

Alpha SPC ← →

1 Press [F1](Alpha) key to be entering alphabet letter mode.

Rename Old name [TOPCON .DAT] New name [HIL ] Num SPC ← →

2 Enter Alphabets. *1)

Type “H” Move cursor

Type “I” Type “L” Type “ ”

3 Press [F1](Num) key to be entering numeric mode.

Rename Old name [TOPCON .DAT] New name [HIL 104 ]

Alpha SPC ← →

4 Press [ENT] when complete. [ENT]

*1) When the same alpha key is to be typed two or more times consecutively, press [F4]( →) key between characters. This moves the cursor to the right. *2) Extensions can not be changed.

[9][9] · Input “104” · [1][0][4]

Page 33 of the Topcon GTS-822A user manual — 2 PREPARATION FOR MEASUREMENT
Page 33 · click to enlarge
Page 33

2 PREPARATION FOR MEASUREMENT

2.10 Memory Card

How to insert a memory card

Topcon GTS-822A — 2 PREPARATION FOR MEASUREMENT diagram (page 33)
Fig. 24
1. Pull the card cover lever to open the card cover. 2) Insert a memory card until the card guide is up. 3) Close the card cover.
1. Pull the card cover lever to open the card cover. 2) Pull down the card guide. 3) Extract the memory card.
Page 34 of the Topcon GTS-822A user manual — 2 PREPARATION FOR MEASUREMENT
Page 34 · click to enlarge
Page 34

2 PREPARATION FOR MEASUREMENT

2.11 Inclination of Prism and Measuring Error

For the best results, aim or point prisms in the direction of the GTS-820A series so that maximum signal can be returned to the instrument. Sighting prism obliquely because of inclined settings, may result in measuring errors. These errors will be proportional to the misalignment as showing in following graphs. The more misalignment of the prism, the more error in measurement. Measured data can be different according to the prism constant value. This can occur when a prism is moving. Pin-pole prism set L1 (for one-person surveying) and pin-pole prism holder L1 (for fixed point observation) are designed to minimize measuring error in such case. Make the best use of them. In case you are forced to use the normal prism in inclined state because there is no other way possible, we recommend to use switching holder, prism constant value (0 or 30mm), and set to 30mm (Compensation value of -30mm).

Topcon GTS-822A — 2 PREPARATION FOR MEASUREMENT diagram (page 34)
Fig. 25
Page 35 of the Topcon GTS-822A user manual — 2 PREPARATION FOR MEASUREMENT
Page 35 · click to enlarge
Page 35

2 PREPARATION FOR MEASUREMENT

l Prism type-2 (Normal prism)

Topcon GTS-822A — 2 PREPARATION FOR MEASUREMENT diagram (page 35)
Fig. 26

l Prism type - 3 or 5 (Prism unit A2/A3)

(Example) In case Prism constant value (C) = 0mm, Prism inclination = 20°, Measuring distance = 100m by Prism type-2 : l Distance error is : From the graph prism type-2, the distance error shows in increasing range quantity 2.5mm along curved line of C=0 when prism inclination is 20°.

l Angle error is : From the graph prism type-2, along curved line of C=0 with prism inclination of 20°, find angle error quantity (14.2mm) and calculate angle error by the following formula.

Angle error = Angleerror range Measuring dis ce tan -1 tan

= 14.2

100x103 -1 tan

=29″

Page 36 of the Topcon GTS-822A user manual — 3.1 Automatic Tracking
Page 36 · click to enlarge
Page 36

3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION 3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION

WARNING

l Cause eye injury or blindness. Do not stare into beam.

CAUTION

l Let the laser beam reach the aimed object or the target without anybody else in the laser beam path. In case you operate laser beam open, avoid radiating laser beam to the height of man's head. It is quite possible for the beam to enter into one's eyes, and it is possible to lose visual sight temporarily, and lose one's caution and awareness of other dangers - avoid glaring beam.

3.1 Automatic Tracking

Measuring the moving target in automatic tracking mode. l The Coarse (10mm) mode is used for the moving target. l Use a keyboard on the eyepiece side. When the keyboard on the opposition side is used an error will be displayed to protect a worker from the radiation of the laser.

Operating procedure Option Display

1 Manually collimate the target prism using V/H jog/shuttle.

V87°55'45" HR: 180°44'12" SD HD NEZ 0SET HOLD P1 ↓

2 Press the star [*] key to show the star key options. [*]

2003-10-10 14:30:40

3 Press the [F1] key. The mode will be automatic tracking mode. The instrument searches the prism and tracks automatically.

V87 ° 55'45" HR: 180 ° 44'12" SD HD NEZ 0SET HOLD P1 ↓

1↓

Page 37 of the Topcon GTS-822A user manual — Searching status
Page 37 · click to enlarge
Page 37

3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION

4 Choose measuring modes by pressing the soft keys. Measuring starts. Sample: Horizontal distance measuring

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: < PPM 0.0 VD: (m) *c.R MEAS MODE VH SD NEZ P1↓

l If the target prism is lost during auto tracking status, the instrument will automatically change to Waiting status and symbol mark will be switched. If the target is found during Waiting status, tracking resumes, and if not, status changes to Searching status. When the target prism is found, tracking will resume.

Automatic tracking

Tracking status

Normal mode

The target prism is lost

The target prism is found

Waiting status

The target prism is not found for some time

Searching status

l The following symbol marks are indicated at the right side of the display. In all these status, laser beam is emitting.

l Auto tracking status sometimes can be unstable for a few seconds after the optical path is disturbed. l If the center of reticle and the center of the prism is not coincided, you should adjust optical axis for auto-tracking, refer to chapter 9"Check and adjustment". l In the not suitable operating condition in such the atmospheric condition is not good by the heat shimmer, or other bad weather condition, in the long distance of the auto-tracking limit, can be happened not certain tracking or not tracking at the center of the prism.

Show 4 more labels / short text on this page
Star key mode · Tracking status · Waiting status · Searching status
Page 38 of the Topcon GTS-822A user manual — 3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION
Page 38 · click to enlarge
Page 38

3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION

3.2 Automatic Collimation

The function enables to collimate automatically so that the instrument searches for the center of the prism when the telescopic is aimed a prism roughly. Use this mode for the object which is stable. l You can select Fine or Course mode for the distance measurement in auto-collimation.

Operating procedure Option Display

1 Manually collimate the target prism roughly using V/H jog/shuttle.

V87°55'45" HR: 180°44'12" SD HD NEZ 0SET HOLD P1 ↓

2 Press the star [*] key. [*]

2003-10-10 14:30:40

3 Press the [F2] key. The instrument begins to collimate When it searches the prism.

V87 ° 55'45" HR: 180 ° 44'12" SD HD NEZ 0SET HOLD P1 ↓

4 Choose measuring modes by pressing the soft keys. Measuring starts. Sample: Horizontal distance measuring

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: < PPM 0.0 VD: (m) *c.R MEAS MODE VH SD NEZ P1↓

l In case the instrument could not find the prism during auto-collimating, the auto-collimating mode returns to normal mode after displaying the mark as follows.

l If any key is pressed during auto-collimating, the auto-collimating mode returns to normal mode. l After auto-collimating is finished, the instrument does not track the prism even if the prism is moved. l The auto-tracking can be done correctly in the time of shaking prism, or in bad weather condition is not good by the heat shimmer. The above caution mark will be displayed after 10 seconds and the auto- tracking will be finished.

1↓

Page 39 of the Topcon GTS-822A user manual — 3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION
Page 39 · click to enlarge
Page 39

3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION

3.3 Range of Laser for Auto-tracking and Auto-collimating

The range of laser at the long distance is within ±30' as shown in following. So you had better collimate the prism so that the prism may be located within this range of laser in the first step. As for it, rapid automatic collimating and automatic tracking becomes possible. If the target prism is out of this range, time for searching mode will be necessary.

Topcon GTS-822A — 3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION diagram (page 39)
Fig. 27

The range of the laser beam for auto-tracking in a short distance is same as a telescopic filed of view. Therefore, quick starting of auto-tracking and auto-collimating are possible if the prism is contained in the telescopic field of view.

Page 40 of the Topcon GTS-822A user manual — 2) Search Range
Page 40 · click to enlarge
Page 40

3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION

3.4 Setting Parameters for Auto-Tracking

A proper setting for each parameter are necessary for custom use. The setting of the parameters can be done in the star key mode.

3.4.1 Setting Items

Items Selecting item Contents

SEARCH PATTERN

PATTERN 1 The search range is the area to searched for the prism by rotating the telescope and body in searching. PATTERN 2

SEARCH RANGE

V:0° to 90° H:0° to180°

The search range is the area to searched for the prism by rotating the telescope and body in searching. The SEARCH range is decided from the point where the prism lost, and the values will be set to plus and minus directions in horizontal and vertical. Also it is enable to set each search pattern separately.

WAIT TIME 0:00 to1:00:00 (1sec. step)

The time the prism is lost before GTS-820A series starts the searching. If the mode is set to [HOLD], mode will not change to searching. HOLD

TRACKING SPEED

SURVEY Select your purpose.

MACHINE CONTROL

REFLECTOR TYPE

PRISM The type of the reflector can be selected.

REFLECTOR TAPE

PREDICTION CTRL TIME

0.5sec./ 1sec. / 2sec. /3sec. / 4sec / 5sec.

After the instrument loses a prism, the time (prediction operation time) for the instrument to continue moving operation can be set up.

1) Search Patterns

The search pattern is the rotating method of telescope and instrument to find the target prism in search mode. Search pattern includes the following 2 ways that can be selected.

This pattern can be selected to search the prism at the point where the prism is lost. Instrument searches in up down direction gradually from the point where the prism is lost. The searching is arranged to 2 times until the prism is found. The auto tracking mode changes to manual mode when the reflector could not found out within 2 times searching, and returns to the point where the reflector is lost.

PATTERN 1

This pattern can be selected to search for the prism. The search pattern tries to locate the prism in a very short time. The searching is arranged to 2 times until the reflector is found. The auto tracking mode changes to manual mode when the reflector could not found out within 2 times searching, and returns to the point where the reflector is lost.

PATTERN 2

1. Things like heat haze might interfere with the tracking system in the long distance, near limit of auto tracking range, in search mode. 2) Reaction by rotating of instrument in search mode is serious. Be sure of each connection part of the tribrach or tripod are firmly.

2) Search Range

The search range is the area to searched for the prism by rotating the telescope and body in Searching. The Search range is decided from the point where the prism lost, and the values will be set to plus and minus directions in horizontal and vertical. Select search pattern first, and set the search range to the selected search pattern. Also it is enable to set each search pattern separately.

Page 41 of the Topcon GTS-822A user manual — 6) Prediction operating time
Page 41 · click to enlarge
Page 41

3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION

[Example] SEARCH RANGE10 ° in horizontal, 5 ° in vertical
Topcon GTS-822A — 3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION diagram (page 41)
Fig. 28

Setting Search range requires consideration. The items to think about: optical path interrupted by other objects; collimated point from GTS-820A series to prism is shifted after Turning and Searching Command; possible other prisms, targets, or other objects to interfere with tracking the desired prism; and many other examples all play a role in determining the search range. Note: This search range is only for auto-tracking function. The search range of auto-collimating is fixed as ±5° in both directions horizontal and vertical.

3) Wait Time

The time the prism is lost before GTS-820A series starts the searching. Setting time is 1second step maximum 60 minutes. If the mode is set to [HOLD], mode will not change to searching.

4) Tracking Speed

Choose the mode of “Survey” or “Machine Control” according to the purpose of measurement.

l In case requiring auto aiming in high accuracy to the prism which is still. l Suitable for fixed point observation, management of landslides, surveying displacement of dam. l When beginning auto-tracking, the instrument needs to collimate stable prism.

SURVEY

l Suitable for controlling of construction machinery or real time surveying of variety traveling objects. l When beginning auto-tracking, the instrument can track a prism, even if the prism is moving.

MACHINE CONTROL

5) Reflector type

You can choose a reflector type according to reflective objects such as Prism-2 or reflector tape. This setting will reduce incorrect tracking.

6) Prediction operating time

After the instrument loses a prism, the time (prediction operation time) for the instrument to continue moving operation can be set up. During auto tracking operation, when auto tracking axis between the instrument and a prism is intercepted by a tree etc., the moving is continued supposing a motion (prediction) of the prism till then. It is effective in auto tracking operation after the prism is intercepted with the obstacle by this function. When an obstacle is large, the prediction operation time should be set up long. Moreover, when you want to terminate auto tracking operation immediately at the point which missed the prism, and to be changed into a search state. Prediction operation time should be set up short.

Page 42 of the Topcon GTS-822A user manual — TRACKING SPEED MACHINE CONTROL
Page 42 · click to enlarge
Page 42

3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION

3.4.2 How to set the parameters

Sample settingSet TRACKING SPEED to [MACHINE CONTROL]

Operating procedure Option Display

1 Press the star [*] key to be in star key mode. [*]

2003-10-10 14:30:40

2 Press the [F3] key to select the setting parameters for auto-tracking.

F1:SEARCH PATTERN F2:SEARCH RANGE F3:WAIT TIME

P ↓

3 Press the [F6](P↓) key to get the menu on page 2.

F1:TRK SPEED F2:REFLECTOR TYPE F3:PREDICTION CTRL TIME

P ↓

4 Press the [F1](TRK SPEED) key. [F1]

TRACKING SPEED SURVEY

5 Press the [F6](↓) key to select [MACHINE CONTROL].

TRACKING SPEED MACHINE CONTROL

[ENT]

6 Press the [ENT] key to decide.

1↓ · ↑ ↓ · ↑ ↓

Page 43 of the Topcon GTS-822A user manual — B
Page 43 · click to enlarge
Page 43

4 STANDARD MEASUREMENT MODE 4 STANDARD MEASUREMENT MODE

Topcon GTS-822A — 4 STANDARD MEASUREMENT MODE 4 STANDARD MEASUREMENT MODE diagram (page 43)
Fig. 29

STANDARD MEASUREMENT MODE Angle measurement, Distance measurement, Coordinate measurement .

4.1 Angle Measurement

4.1.1 Measuring Horizontal Angle Right and Vertical Angle Make sure the mode is in Angle measurement.

1 Collimate the 1st target (A). Collimate

V87 ° 55'45" HR: 180 ° 44'12"

A

SD HD NEZ 0SET HOLD P1 ↓

2 Set horizontal angle of target A at 0° 00' 00". Press [F4](0 set) key and [F6](SET) key.

H-0SET HR: 00 ° 00'00" ESC SET

V87 ° 55'45" HR: 00 ° 00'00" SD HD NEZ 0SET HOLD P1 ↓

3 Collimate the 2nd target (B). The required H/V angle to target B will be displayed.

V87 ° 55'45" HR: 123 ° 45'50" SD HD NEZ 0SET HOLD P1 ↓

B

Reference : How to Collimate

1 Point the telescope toward the light. Turn the diopter ring and adjust the diopter so that the cross hairs are clearly observed. (Turn the diopter ring toward you first and then backward to focus.) 2 Aim the target at the peak of the triangle mark of the sighting collimator. Allow a certain space between the sighting collimator and yourself for collimating. 3 Focus the target with the focusing knob.

*If parallax is created between the cross hairs and the target when viewing vertically or horizontally while looking into the telescope, focusing is incorrect or diopter adjustment is poor. This adversely affects precision in measurement or survey. Eliminate the parallax by carefully focusing and using diopter adjustment.

Telescope eyepiece (Diopter ring)

Show 4 more labels / short text on this page
Collimate · Focusing knob · Åá Åá · Åá Åá
Page 44 of the Topcon GTS-822A user manual — 4 STANDARD MEASUREMENT MODE
Page 44 · click to enlarge
Page 44

4 STANDARD MEASUREMENT MODE

4.1.2 Switching Horizontal Angle Right/Left Make sure the mode is Angle measurement.

1 Press [F6](↓)key to get the function as on page 2.

V : 87°55'45" HR: 120°30'40" SD HD NEZ 0SET HOLD P1↓ TURN HSET R/L V/% TILT P2↓

2 Press [F3](R/L) key. The mode Horizontal angle Right (HR) switches to (HL) mode.

V : 87°55'45" HL: 239°29'15" PSM 0.0 PPM 0.0 (m) *F.R TURN HSET R/L V/% TILT P2↓

3 Measure as HR mode.

l Every time pressing [F2](R/L) key is pressed, HR/HL mode switches. l HR/HL switching can be turned OFF. Refer to Chapter 8 “PARAMETERS SETTING MODE” .

4.1.3 Measuring from the Required Horizontal Angle 1) Setting by Holding the Angle Make sure the mode is angle measurement.

1 Set the required horizontal angle, using Horizontal jog/shuttle.

V90 ° 10'20" HR: 70 ° 20'30" SD HD NEZ 0SET HOLD P1 ↓

2 Press [F5](HOLD) key. [F5]

Holding HR70 ° 20'30" ESC REL

3 Collimate the target.*1) Collimate

4 Press [F6](REL) key to finish holding the horizontal angle. The display turns back to normal angle measurement mode.

V90 ° 10'20" HR: 70 ° 20'30" SD HD NEZ 0SET HOLD P1 ↓

*1)To return to the previous mode, press [F1](ESC) key.

Display · angle

Page 45 of the Topcon GTS-822A user manual — 4.1.4 Vertical Angle Percent Grade(%) Mode
Page 45 · click to enlarge
Page 45

4 STANDARD MEASUREMENT MODE

2. Setting a Horizontal Angle from the Keys Make sure the mode is Angle measurement.

1 Collimate the target. Collimate

V : 90°10'20" HR: 120°30'40" SD HD NEZ 0SET HOLD P1↓ TURN HSET R/L V/% TILT P2↓

2 Press [F6](↓) key to get the function as on page 2, and press [F2](HSET) key.

H-SET HR: H-SET HR:70.203

3 Input the required horizontal angle. *1) For example:70°20'30"

EXIT BS

4 Press [ENT] key. *2) When completed, normal measuring from the required Horizontal angle is possible.

[ENT]

V90 ° 10'20" HR: 70 ° 20'30" SD HD NEZ 0SET HOLD P1 ↓

*1)To revise wrong value, move cursor with [F6](BS) key, or input from the beginning by [F1](EXIT) key to correct value. *2)With wrong input value (for example 70'), setting will not be completed. Input again from step 3.

4.1.4 Vertical Angle Percent Grade(%) Mode

Make sure the mode is Angle measurement.

1 Press [F6](↓) key to get the function as on page 2.

V : 90°10'20" HR: 120°30'40" SD HD NEZ 0SET HOLD P1↓ TURN HSET R/L V/% TILT P2↓

2 Press [F4](V/%) key. *1) [F4]

V%-0.30 % HR: 120 ° 30'40" TURN HSET R/L V/% TILT P2 ↓

*1) Every time pressing the [F4](V/%) key, the display mode switches.

Input value

Page 46 of the Topcon GTS-822A user manual — [ENT]
Page 46 · click to enlarge
Page 46

4 STANDARD MEASUREMENT MODE

4.1.5 Automatic Rotation to a Required Horizontal and Vertical Absolute Angle The GTS-820A series can be rotated to a required horizontal and vertical absolute angle by direct key input. Example: Both vertical and horizontal angle

1 Press the [F6](↓) key to display the second soft key page.

V : 87°55'45" HR: 120°30'40" SD HD NEZ 0SET HOLD P1↓ TURN HSET R/L V/% TILT P2↓

2 Press the [F1](TURN) key. [F1]

TURN(Absolute) F1. V angle F2. H angle F3. V/H angle

3 Press the [F3] key. [F3]

TURN ( Absolute ) V : HR: EXIT BS

4 Input the vertical angle to be rotated and press [ENT] key. *1) For example : 93°10'40"

[ENT]

5 Input the horizontal angle to be rotated, and press [ENT] key. For example : 160°20'10"

TURN ( Absolute ) V93 ° 10'10" HR: 160 ° 20'10" < Rotating... >

The instrument will start to rotate. *2) When the instrument has finished rotating *3), the instrument will return to the previous mode.

*1) Setting range for rotation is ; 0°00' 00"≤ HR ≤+359°59' 59" 0°00' 00"≤ V ≤ +359°59' 59" *2) Press any key except power key to stop rotating in emergency during operation. *3) You can select a accuracy of the actual stopping angular positions. Refer to Chapter 8 “PARAMETERS SETTING MODE” .

V angle · [ENT] H angle

Page 47 of the Topcon GTS-822A user manual — 4.2.3 Distance Measurement (Continuous Measurement)
Page 47 · click to enlarge
Page 47

4 STANDARD MEASUREMENT MODE

4.2 Distance Measurement

4.2.1 Setting of the Atmospheric Correction When setting the atmospheric correction, obtain the correction value by measuring the temperature and pressure. Setting the atmospheric correction is in the STAR key (H) mode, see Chapter 11 “SETTING ATMOSPHERIC CORRECTION” .

4.2.2 Setting of the Correction for Prism Constant Topcon's prism constant value is 0. Set correction for prism at 0. If the prism is of another manufacture, the appropriate constant shall be set beforehand. Setting the prism constant value is in the STAR key (H) mode, see Chapter 10 “SETTING THE PRISM CONSTANT VALUE” .

4.2.3 Distance Measurement (Continuous Measurement)

Make sure the mode displays angle measurement.

1 Collimate the center of prism.

V90 ° 10'20" HR: 120 ° 30'40" SD HD NEZ 0SET HOLD P1 ↓

2 Press [F1](SD) key or [F2]( HD )key. *1), 2) [Example] Horizontal distance mode

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: < PPM 0.0 VD: (m) *F.R MEAS MODE VH SD NEZ P1↓

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: 716.661 PPM 0.0 VD: 4.001 (m) *F.R MEAS MODE VH SD NEZ P1↓

The result are shown *3) ~ *6)

*1) The following characters will be shown on the 4th line right hand corner of the display to represent measurement mode. F: Fine meas. mode, C: Coarse (1mm) meas. mode, c: Coarse (10mm) meas. mode. R: Continuous (Repeat) meas. mode , S: Single meas. mode, N: N time meas. mode *2) When EDM is working, the "* " mark appears in the display. *3) The result is shown with buzzer sound. *4) Measurement may repeat automatically if the result is affected by shimmer etc.. *5) To change single measuring, press [F1](MEAS) key. *6) To return to the angle measurement mode, press [F3](VH) key.

Page 48 of the Topcon GTS-822A user manual — [F4][ENT]
Page 48 · click to enlarge
Page 48

4 STANDARD MEASUREMENT MODE

4.2.4 Distance Measurement (Single/N-times Measurement) When presetting the number of times, the instrument measures the distance as the setting times and the average distance will be displayed. When presetting the number of times as 1, it does not display the average distance, because of single measurement. It has been set at single measurement at factory.

1)Setting the number of times Confirm the angle measurement mode.

1 Press [F1](SD) or [F2](HD) key.

V90 ° 10'20" HR: 120 ° 30'40" SD HD NEZ 0SET HOLD P1 ↓

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: PPM 0.0 VD: (m) F.R MEAS MODE VH SD NEZ P1↓ REC SO MEAN m/ft P2↓

2 Press [F6](↓) key to get the function page as 2.

3 Press [F3](MEAN) key. [F3]

Average times N:0 EXIT BS

4 Input the setting the number of times, and press [ENT] key. *1) [Example] 4 times N-times measurement starts.

[F4][ENT]

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: < PPM 0.0 VD: (m) *F.N REC SO MEAN m/ft P2↓

2)Measuring Method Confirm the angle measurement mode.

1 Collimate the center of the prism. Collimate

V90 ° 10'20" HR: 120 ° 30'40" SD HD NEZ 0SET HOLD P1 ↓

2 Select the measurement mode by pressing [F1](SD) or [F2](HD) key. Example: Horizontal distance N-times measurement starts.

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: PPM 0.0 VD: (m) F.N MEAS MODE VH SD NEZ P1↓

Page 49 of the Topcon GTS-822A user manual — 4 STANDARD MEASUREMENT MODE
Page 49 · click to enlarge
Page 49

4 STANDARD MEASUREMENT MODE

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: 54.321 PPM 0.0 VD: 1.234 (m) *F.N MEAS MODE VH SD NEZ P1↓

The average value is displayed following with buzzer sound and “ * ” mark disappears.

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: 54.321 PPM 0.0 VD: 1.234 (m) F.N MEAS MODE VH SD NEZ P1↓

l Press [F1](MEAS) key for re-measuring after the measurement in held. l To return to the continuous measuring , press [F1](MEAS) key twice. l To return to the angle measuring mode , press [F3](VH) key.

Page 50 of the Topcon GTS-822A user manual — [F2] [F2]
Page 50 · click to enlarge
Page 50

4 STANDARD MEASUREMENT MODE

4.2.5 Fine / Coarse Measuring Mode

  • Fine mode : This is a normal distance measuring mode.
Measurement time 0.2mm modeapprox.2.8 seconds
1 mm modeapprox.1.2 seconds The unit to be displayed is 0.2mm or 1mm. (0.001ft or 0.005ft)
  • Coarse mode : This mode measures in shorter time than in fine mode. (1mm) Use this mode for the objects which may be slightly unstable. Measurement time : approx. 0.7 seconds The unit to be displayed is 1mm. (0.005ft)
  • Coarse mode : This mode measures in shorter time than in coarse(1mm) mode. (10mm) Use this mode for stake out measurement. It is very useful when tailing the moving object or carrying out stake-out work. Measurement time : approx. 0.4 seconds The unit to be displayed is 10mm. (0.02ft)

1 Collimate the center of prism. Collimate

V: 90°10'20" HR: 120°30'40" SD HD NEZ 0SET HOLD P1↓

2 Select the measurement mode by pressing [F1](SD) or [F2](HD) key. Example: Horizontal distance Measuring starts.

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: < PPM 0.0 VD: (m) *F.R MEAS MODE VH SD NEZ P1↓

3 Press [F2](MODE) key, the mode changes to Coarse mode. Press [F2](MODE) key again, the mode changes to Tracking mode. *1)

[F2] [F2]

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: PPM 0.0 VD: (m) c.R MEAS MODE VH SD NEZ P1↓

*1) Every time the [F2](MODE) key is pressed, the mode will change as demonstrated. The mode is indicated in the alphabet (F, C, c) on the bottom right of the screen. F: Fine mode, C: Coarse 1mm mode, c: coarse 10mm mode

Page 51 of the Topcon GTS-822A user manual — [F2] [ENT]
Page 51 · click to enlarge
Page 51

4 STANDARD MEASUREMENT MODE

4.2.6 Stake Out (S-O) The stake out distance is the difference between the measured distance and the preset distance. Display value = Measured distance -Standard (Preset) distance The value on the display is the distance in which the rod person must move toward or away from the instrument. A minus (-) sign appearing before the stake out distance indicates that the rod person would move away from the instrument to reach the stake out distance. If the stake out distance is displayed with no sign, indicating positive (+), the rod person toward the instrument to reach the stake out distance. l Stake out operation can be accomplished in any distance measuring mode, horizontal distance (HD), relative elevation (VD), or slope distance (SD). [Example: Relative elevation]

1 Press [F6](P1) key in the distance measuring mode to get the function as in page 2.

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: PPM 0.0 VD: (m) F.R MEAS MODE VH SD NEZ P1↓ TURN SO MEAN m/ft P2↓

2 Press [F2](S-O) key and press [ENT] key.

[F2] [ENT]

SO HD : 0.000 VD : EXIT BS

3 Enter the relative elevation for stake out, and press [ENT] key. The measuring starts.

V : 90°10'20" HR : 120°30'40" PSM 0.0 HD : < PPM 0.0 dVD : (m) *F.R TURN SO MEAN m/ft P2↓

4 Collimate the target (Prism).

The difference between the measured distance and the standard distance is displayed.

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: 12.345 PPM 0.0 dVD: 0.09 (m) *F.R TURN SO MEAN m/ft P2↓

l To return to normal distance measurement mode, reset the standard distance to “ 0 ” or turn the power switch off (Resume mode: OFF) once.

Enter value [ENT]

Page 52 of the Topcon GTS-822A user manual — E
Page 52 · click to enlarge
Page 52

4 STANDARD MEASUREMENT MODE

4.3 COORDINATE MEASUREMENT

4.3.1 Setting Coordinate Values of Occupied Point The occupied point coordinates (NEZ) can be preset in the GTS-820A Series to calculate the unknown point coordinates. It is possible to retain the occupied coordinates in memory once the power is turned OFF if the (NEZ mem) is ON in the Parameter Setting Modes. IF (NEZ mem) is OFF in the Parameter Setting Modes, the occupied coordinates will be retained only if you choose (Resume ON) when shutting the power OFF. For instructions on how to select NEZ memory ON/OFF, refer to Chapter 8 “PARAMETERS SETTING MODE” .

N

z n

Inst.PointC

E

e

Confirm the angle measurement mode.

V90 ° 10'20" HR: 120 ° 30'40" SD HD NEZ 0SET HOLD P1 ↓

1 Press [F3](NEZ) key.

N : < E : PSM 0.0 Z : PPM 0.0 (m) *F.R MEAS MODE VH SD HD P1↓ TURN HT MEAN m/ft SET P2↓

2 press [F6](↓) key to get the function as on page 2.

3 Press [F5](SET) key. The previous data will be shown.

Setting occ. point N12345.6700 E : 12.3400 Z : 10.2300 EXIT BS

Prism (n,e,z) · Origin(0,0,0)

Page 53 of the Topcon GTS-822A user manual — [ENT]
Page 53 · click to enlarge
Page 53

4 STANDARD MEASUREMENT MODE

4 Input new data and press [ENT] key. *1)

N coord.

Setting occ. point N0.0000 E : 0.0000 Z : 0.0000 EXIT BS

[ENT] E coord.

[ENT] Z coord.

[ENT]

N : < E : PSM 0.0 Z : PPM 0.0 (m) *F.R TURN HT MEAN m/ft SET P2↓

Measuring starts.

*1)To cancel the setting, press [F1](EXIT) key.

Complete

Page 54 of the Topcon GTS-822A user manual — [ENT]
Page 54 · click to enlarge
Page 54

4 STANDARD MEASUREMENT MODE

4.3.2 Setting of the Instrument Height / Prism Height The instrument height and prism height are used to compute the ground elevation of the unknown point. If the option to store NEZ is (on), the instrument and prism heights will be stored in memory when power is turned off. Confirm the angle measurement mode.

V90 ° 10'20" HR: 120 ° 30'40" SD HD NEZ 0SET HOLD P1 ↓

1 Press [F3](NEZ) key.

N : E : PSM 0.0 Z : PPM 0.0 (m) *F.R MEAS MODE VH SD HD P1↓ TURN HT MEAN m/ft SET P2↓

2 Press [F6](↓) key from the coordinate measurement mode to get the function as in page 2.

3 Press [F2](HT) key to type in the instrument and prism height. Previous data will be shown.

Inst. Ht1.230 m R. Ht : 1.340 m EXIT BS

4 Input instrument height, and press [ENT] key.*1)

Inst. HT

[ENT]

5 Input prism height, and press [ENT] key.

N : E : PSM 0.0 Z : PPM 0.0 (m) *F.R TURN HT MEAN m/ft SET P2↓

[ENT]

The display returns to coordinate measuring mode.

*1)To cancel the setting, press [F1](EXIT) key.

Prism HT

Page 55 of the Topcon GTS-822A user manual — 4 STANDARD MEASUREMENT MODE
Page 55 · click to enlarge
Page 55

4 STANDARD MEASUREMENT MODE

4.3.3 Execution of Coordinate Measuring Measure the coordinates by entering the instrument height and prism height, coordinates of unknown point will be measured directly.

l When setting coordinate values of occupied point, see Section 4.3.1“Setting Coordinate Values of Occupied Point” . l When setting the instrument height and prism height, see Section 4.3.2“Setting of the Instrument Height / Prism Height” . l The coordinates of the unknown point are calculated as shown below and displayed:

Coordinates of occupied point : (N0, E0, Z0) Instrument height : Inst.h Prism height : R.h Vertical distance (Relative elevation) : z Coordinates of the center of the prism, originated from the center point of the instrument : (n,e,z) Coordinates of unknown point : (N1, E1, Z1)

N1 = N0 + n E1 = E0 + e Z1 = Z0 + Inst.h + z - P.h

Coordinates of the center of the prism, originated from the center point of the instrument (n,e,z)

Center point of the instrument (No, Eo, Zo + Inst.h)

(N1, E1, Z1)

Occupied point (No, Eo, Zo)

Origin (o, o, o)

Confirm the angle measurement mode.

1 Set coordinates values of occupied point and instrument/prism height. *1) 2 Set the direction angle of known point A. *2) Set direction

V90 ° 10'20" HR: 120 ° 30'40" SD HD NEZ 0SET HOLD P1 ↓

3 Collimate target B. Collimate

4 Press [F3](NEZ) key.*3) Measuring starts.

N : < E : PSM 0.0 Z : PPM 0.0 (m) *F.R MEAS MODE VH SD HD P1↓

Unknown point · angle

Page 56 of the Topcon GTS-822A user manual — 4 STANDARD MEASUREMENT MODE
Page 56 · click to enlarge
Page 56

4 STANDARD MEASUREMENT MODE

The result will be shown.

N : 12345.6789 E : -12345.6789 PSM 0.0 Z : 10.1234 PPM 0.0 (m) *F.R MEAS MODE VH SD HD P1↓

*1) In case the coordinate of instrument point is not entered, (0,0,0) will be used as the default for the instrument point. The instrument height will be calculated as 0 when the instrument height is not entered. *2) The prism height will be calculated as 0 when the prism height is not set. *3) Refer to Section 4.1.3“Measuring from the Required Horizontal Angle”or Section 4.1.3“Measuring from the Required Horizontal Angle” *4) Pressing [F1](MEAS) key, the measurement mode (Continuous measuring/ N-time measuring) changes. Pressing [F2](MODE) key, the measurement mode (FINE/ COARSE(1mm)/ COARSE(10mm)) changes. l To return to the normal angle or distance measuring mode, press [F6](P2↓) key to return to the function as on page 1 and press [F3](VH),[F4](SD) or [F5](HD) key.

Page 57 of the Topcon GTS-822A user manual — [ * ] Tilt OFF
Page 57 · click to enlarge
Page 57

4 STANDARD MEASUREMENT MODE

4.4 DATA OUTPUT

Result of measurement is transferred to Data Collector (FC series) from GTS-820A series.

[Example: Distance measurement mode] Confirm the distance measurement mode.

1 Operate the data collector to measure the distance. Measurement will be started.

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: < PPM 0.0 VD: (m) *F.R MEAS MODE VH SD NEZ P1↓

2 The result will be shown and transferred to the Data Collector.

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: 10.1234 PPM 0.0 VD: 1.234 (m) *F.R REC > > >

3 The mode will automatically return to the distance measurement mode.

V : 90°10'20" HR: 120°30'40" PSM 0.0 HD: 10.1234 PPM 0.0 VD: 1.234 (m) *F.R MEAS MODE VH SD NEZ P1↓

The following data will be output at each mode.

Angle mode (V,HR or HL) (V in percent) V, HR (or HL)

Horizontal distance mode (V, HR, HD, VD) V, HR, HD, VD

Slope distance mode (V, HR,SD) V, HR, SD,HD

Coordinate mode N, E, Z, HR

l The display and the output at the coarse (1mm) mode are the same as the contents above. l Output at the coarse (10mm) mode is displayed as distance data only (HD, VD or SD).

The information of GTS-820A series regarding tracking auto-tracking are added to the protocol of Topcon Total Station system so far. Also you can add utility information such as battery remaining, EDM mode, auto-tracking mode, normal/ reversed face information, Tilt information if you like. For selecting, refer to Chapter 8 “PARAMETERS SETTING MODE” .

During an utility function selection, measurement will be continued whenever tilt over. The tilt over will not be compensated here. In case tilt over, the tilt information will be displayed on the upper right screen as the following marks during the utility function is selected.

V : 90° 10'20" [t] HR: 120° 30'40" PSM 0.0 HD: < PPM 0.0 VD: (m) *c.R MEAS MODE VH SD NEZ P1↓

Marks Status of tilt

[t] Under tilt compensation

[ * ] Tilt OFF

Show 4 more labels / short text on this page
Operating procedure Display · Mode Output · Tilt information · [?] Tilt Over
Page 58 of the Topcon GTS-822A user manual — 4 STANDARD MEASUREMENT MODE
Page 58 · click to enlarge
Page 58

4 STANDARD MEASUREMENT MODE

l Control by interface for Topcon AP-L1A system, see Chapter 5 “PROGRAM MODES” -[EXT.LINK] section.

l When using other wireless modem or optical remote controller, select to [None] for the protocol of communication in Chapter 8 “PARAMETERS SETTING MODE” .

Page 59 of the Topcon GTS-822A user manual — 5 PROGRAM MODES 5 PROGRAM MODES
Page 59 · click to enlarge
Page 59

5 PROGRAM MODES 5 PROGRAM MODES

2003-10-10 15:30:40

[Press [F1] key.]

Prog Std Mem Comm Adj Para

PROGRAM MODE (APPLICATION MEASUREMENT) 1.Setting a Horizontal Angle 2.Retaining a Coordinate (STORE-NEZ) 3.Remote Elevation Measurement (REM) 4.Missing Line Measurement (MLM) 5.Line Measurement (LINE) 6.Offset Measurements (OFF SET) 6.External Link

l The loaded measuring programs are added on this menu.

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

[F6](MORE) key Programs F1 LINE p 7/7 F2 OFFSET p F3 EXT.LINK p MORE

Page 60 of the Topcon GTS-822A user manual — [ENT]
Page 60 · click to enlarge
Page 60

5 PROGRAM MODES

5.1 Setting a Direction Angle for Backsight Orientation

(Entering the instrument and backsight coordinate values) From the coordinate value of backsight point (bearing point) and instrument point, the direction angle from the instrument point to the backsight point can be set.

N

E

ExampleBacksight point A : N coordinate 54.321m, E coordinate 12.345m

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

1 Press [F1](BS) key. Current data will be displayed. *1)

Setting Direction Angle BS:M-POINT N : 1234.567 m E : 2345.678 m INP OK

2 Press [F6](OK) key. 3 Input N and E coordinate of backsight point A.

Setting Direction Angle BS:T-POINT N : 54.321 m E : 12.345 m EXIT BS

ExampleN coordinate;54.321m : E coordinate;12.345m

[ENT]

Setting Direction Angle BS HR320°10'20" > Set OK ? EXIT YES NO

4 Sight backsight point A.

5 Press [F5](YES) key.

The display returns to main menu.

*1)If you need to change the occupied point data, press [F1](INP) key and input new data.

Show 6 more labels / short text on this page
Backsight point A · Instrument point C · Direction angle · [F6] N data · [ENT] E data · Complete
Page 61 of the Topcon GTS-822A user manual — Store NEZ HR : 100°10'20" HD * < m
Page 61 · click to enlarge
Page 61

5 PROGRAM MODES

5.2 Retaining a Coordinate (STORENEZ)

Suppose the instrument P0 moves to P1, P2, P3, etc. and the coordinate at P1, P2, P3 etc., last point will be retained in the memory, after moving, as from the origin point.

Topcon GTS-822A — 5 PROGRAM MODES diagram (page 61)
Fig. 30

l Set the coordinate value of instrument point P0 and set the direction angle from instrument point P0 toward known point A .

Topcon GTS-822A — 5 PROGRAM MODES diagram (page 61)
Fig. 31

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

3 Collimate target P1 prism which the instrument moves.

Store NEZ HR : 100°10'20" HD * < m

Store NEZ HR100°10'20" HD * 123.456 m
Page 62 of the Topcon GTS-822A user manual — P 0
Page 62 · click to enlarge
Page 62

5 PROGRAM MODES

5 Press [F6](SET) key. Coordinate of P1 will be displayed.

Store NEZ N : 123.456 m E : 12.345 m Z : 1.234 m > SET OK? YES NO

6 Press [F5](YES) key. Coordinate of P1 will be decided.

The display return to main menu.

Turn power off and move instrument to P1 ( Prism P1 move to P0).

P1

7 After the instrument is set up at P1, turn power on and be measurement possible.

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

8 Press [F2](STORE) key. [F2]

Retaining a Coordinate 1.Store NEZ 2.Recall NEZ

9 Press [F2](Recall NEZ) key.

HR: 300°10'20" > Set OK? YES NO

10 Collimate P0, the former instrument point.

P 0

11 Press [F5](YES) key. [F5]

The coordinates at P1 and direction angle toward P0 are set.

The display return to main menu.

12 Repeat the procedure 1 ~11 as much as you wish.

*1)To reset the instrument height or prism height, press [F5](HT) key.

Show 8 more labels / short text on this page
Complete · Power off · Move to · Power on · Select program · Recall NEZ · Collimate · Complete
Page 63 of the Topcon GTS-822A user manual — 5 PROGRAM MODES
Page 63 · click to enlarge
Page 63

5 PROGRAM MODES

5.3 Remote Elevation measurement (REM)

To obtain elevation of the point at which setting the target prism is not possible, place the prism at any point on the vertical line from the target then carry out REM procedure as follows.

Topcon GTS-822A — 5 PROGRAM MODES diagram (page 63)
Fig. 32

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

REM (2)Horizontal Distance HD * < m MEAS SET

Page 64 of the Topcon GTS-822A user manual — REM (1) Horizontal Distance HD : 123.456 m MEAS SET
Page 64 · click to enlarge
Page 64

5 PROGRAM MODES

Horizontal distance (HD) between the instrument and prism will be shown.

REM (2)Horizontal Distance HD123.456 m MEAS SET

6 Press [F6](SET) key. The prism position will be decided. *1)

REM

VD : 0.234 m EXIT P.h HD SET

7 Collimate target K. Vertical distance (VD) will be shown. *2)

REM

K

VD : 1.456 m EXIT P.h HD

*1)To return to procedure 3, press [F2](P.h) key. To return to procedure 4, press [F3](HD) key. *2)To return to main menu, press [F1](EXIT) key.

2)Without prism height input.

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

1 Press [F3](REM) key. [F3]

REM Prism height 1.YES 2.NO

2 Press [F2](NO) key. [F2]

REM (1)Horizontal Distance HDm

MEAS

3 Collimate prism.

P

REM (1)Horizontal Distance HD* < m MEAS SET

4 Press [F1](MEAS) key. Measuring starts.

Horizontal distance (HD) between the instrument and prism will be shown.

REM (1) Horizontal Distance HD : 123.456 m MEAS SET

Collimate · Collimate

Page 65 of the Topcon GTS-822A user manual — REM
Page 65 · click to enlarge
Page 65

5 PROGRAM MODES

5 Press [F6](SET) key. The prism position will be decided.

REM (2)Vertical Angle V120°30'40" SET

6 Collimate ground point G. Collimate

REM (2)Vertical Angle V95°30'40" SET

G

7 Press [F6](SET) key. The position of point G will be decided. *1)

REM

VD0.000 m EXIT HD V

8 Collimate target K. Vertical distance (VD) will be shown. *2)

REM

K

VD9.876 m EXIT HD V

*1)To return to procedure 3 , press [F2](HD) key. To return to procedure 6 , press [F3](V) key.

*2)To return to main menu, press [F1](EXIT) AND [F5](YES) key.

Collimate

Page 66 of the Topcon GTS-822A user manual — 5 PROGRAM MODES
Page 66 · click to enlarge
Page 66

5 PROGRAM MODES

5.4 Missing Line Measurement (MLM)

Measurement for horizontal distance (dHD), slope distance (dSD) and elevation (dVD) between two target prisms. MLM mode has two mods. 1.(A-B, A-C):Measurement is A-B, A-C, A-D, 2.(A-B, B-C):Measurement is A-B, B-C, C-D,

[Example] 1. (A-B, A-C) l Procedure of 2. (A-B, B-C) mode is completely same as MLM-1 mode.

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

1 Press [F4](MLM) key. [F4]

Missing Line Measurement 1.(A-B, A-C) 2.(A-B, B-C)

2 Press [F1](A-B, A-C) key. [F1]

MLM 1 Horizontal Distance 1 HD : m MEAS SET

Prism A · Prism B · Prism C Instrument

Page 67 of the Topcon GTS-822A user manual — C [F1]
Page 67 · click to enlarge
Page 67

5 PROGRAM MODES

3 Collimate prism A, and press [F1](MEAS) key.

A [F1]

MLM 1 Horizontal Distance 1 HD * < m

Horizontal distance (HD) between the instrument and prism A will be shown.

MEAS SET

MLM 1 Horizontal Distance 1 HD : 123.456 m

MEAS SET

4 Press [F6](SET) key. [F6]

MLM 1 Horizontal Distance 2 HD : m MEAS SET

5 Collimate prism B and press [F1](MEAS) key.

MLM 1 Horizontal Distance 2 HD * < m

B

Horizontal distance (HD) between the instrument and prism B will be shown.

MEAS SET

MLM 1 Horizontal Distance 2 HD * 246.912 m

MEAS SET

6 Press [F6](SET) key. The horizontal distance (dHD) relative elevation (dVD) and slope distance between prism A and B.

MLM 1 dHD123.456 m dVD : 12.345 m dSD : 12.456 m EXIT HD

7 To measure the distance between points A and C, press [F2](HD) key. *1)

MLM 1 Horizontal Distance 2 HD : m MEAS SET

8 Collimate point C (Prism C) and press [F1](MEAS) key. Horizontal distance (HD) between the instrument and prism C will be shown.

C [F1]

MLM 1 Horizontal Distance 2 HD : < m MEAS SET

Collimate · Collimate · Collimate

Page 68 of the Topcon GTS-822A user manual — MEAS SET
Page 68 · click to enlarge
Page 68

5 PROGRAM MODES

MLM 1 Horizontal Distance 2 HD * 246.912 m

MEAS SET

9 Press [F6]( SET) key. The horizontal distance (dHD) relative elevation (dVD) and slope distance between prism A and C.

MLM 1 dHD123.456 m dVD : 12.345 m dSD : 12.456 m EXIT HD

10 To measure the distance between points A and D, repeat procedure 7 to 9. *1)

*1)To return to main menu, press[F1](EXIT) and [F5](YES) key.

Page 69 of the Topcon GTS-822A user manual — 5 PROGRAM MODES
Page 69 · click to enlarge
Page 69

5 PROGRAM MODES

5.5 Line Measurement (LINE)

This mode is useful to obtain the line height.

Topcon GTS-822A — 5 PROGRAM MODES diagram (page 69)
Fig. 33

[Example:Input of prism height]

Topcon GTS-822A — 5 PROGRAM MODES diagram (page 69)
Fig. 34

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

1 Press [F6](MORE) key from programs menu to get the next page of programs.

Programs F1 LINE p 7/7 F2 OFFSET p F3 EXT.LINK p MORE

4 Input the prism height and press [ENT] key. Input P.h

Page 70 of the Topcon GTS-822A user manual — LINE G-POINT V : 30°20'10"
Page 70 · click to enlarge
Page 70

5 PROGRAM MODES

5 Collimate prism A and press [F1](MEAS) key. The distance measurement will start.

LINE <STEP-1>P T A HD* < m

A [F1]

MEAS SET

Horizontal distance is displayed.

LINE <STEP-1>PT A HD* 50.234 m

MEAS SET

6 Press [F6] (SET) key, and horizontal distance will be recorded.

LINE <STEP-1>PT B HDm

MEAS SET

7 Collimate prism B and press [F1](MEAS) key. The distance measurement will start.

LINE <STEP-1>PT B HD* < m

B [F1]

MEAS SET

Horizontal distance is displayed.

LINE <STEP-1>PT B HD* 67.543 m

MEAS SET

8 Press [F6] (SET) key, and horizontal distance will be recorded.

LINE VD20.123 m HD: 38.987 m Off: 74.123 m EXIT LH

9 Sight line point L . Measured data to the line point L is displayed. VD:Vertical distance. HD:Horizontal distance from the instrument to L. Off :Horizontal distance from A to L.

10 Press [F2](LH) key. This function is used when measuring the line height from the ground. The procedure is as follows : l Sight the point on the line before pressing this key. l Don‘t move the horizontal tangent screw by setting ground point G.

LINE G-POINT V : 30°20'10"

EXIT SET

Collimate · Collimate · Sight L

Page 71 of the Topcon GTS-822A user manual — EXIT VD NEXT
Page 71 · click to enlarge
Page 71

5 PROGRAM MODES

11 Rotate the vertical tangent screw, and sight ground point G.

LINE G-POINT V : 90°40'20"

EXIT SET

12 Press [F6] (SET) key, line height (LH) and horizontal distance (Off) are displayed.

LINE LH33.765 m Off: 27.521 m

EXIT VD NEXT

l To finish the measurement, press the [F1](EXIT) or [ESC] key. l To return to operation procedure 9, press the [F2](VD) key. l To return to operation procedure 11, press the [F6](NEXT) key.

The NEXT key is used when the ground point G is not clear and you would like to check another ground point G on the same vertical line.

Sight G

Page 72 of the Topcon GTS-822A user manual — [F5](YES)
Page 72 · click to enlarge
Page 72

5 PROGRAM MODES

5.6 Offset measurement (OFFSET)

There are four offset measurement modes in the Offset Measurement.

l Angle offset l Distance offset l Plane offset l Column offset

Programs F1 LINE p 7/7 F2 OFFSET p F3 EXT.LINK p MORE

[F2](OFFSET)

OFFSET MEASUREMENT 1.ANGLE OFFSET 2.DIST. OFFSET 3.PLANE OFFSET 4.COLUMN OFFSET

l Outputting the Measurement Data

The results of offset measurement can be output to external device. In offset measurement mode, the [F4] soft key which assigned (REC) will appear in measured result display.

ANGLE OFFSET HR87 ° 55'45" HD: 20.000 m VD: 5.000 m NEXT SD NEZ REC

[F4](REC)

ANGLE OFFSET HR87 ° 55'45" HD: 20.000 m VD: 5.000 m > REC ? YES NO

[F5](YES)

ANGLE OFFSET HR87 ° 55'45" HD: 20.000 m VD: 5.000 m <REC>

l Distance measurement mode of the offset measurement

Offset measurement will be done by N-time fine measurement mode.

Offset Measurement Menu

Page 73 of the Topcon GTS-822A user manual — ANGLE OFFSET 1.FREE V-ANGLE 2.HOLD V-ANGLE
Page 73 · click to enlarge
Page 73

5 PROGRAM MODES

5.6.1 Angle Offset This mode is useful when it is difficult to set up the prism directly, for example at the center of a tree. Place the prism at the same horizontal distance from the instrument as that of point A0 to measure. To measure the coordinates of the center position, operate the offset measurement after setting the instrument height/prism height.

When measuring coordinates of ground point A1 :Set the instrument height/prism height.

When measuring coordinates of point A0 : Set the instrument height only. (Set the prism height to 0 ).

When sighting to A0, you can select one of two ways. [HOLD] is to fix vertical angle to the prism position even updown the telescope position, and [FREE] is to gear vertical angle to the updown of telescope movement. In case following the vertical angle to the movement of telescope, SD(Slope Distance) and VD(Vertical Distance) will be changed according to the movement of telescope.

Occ. Point

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

1 Press [F6](MORE) key from programs menu to get to the next page of programs.

Programs F1 LINE p 7/7 F2 OFFSET p F3 EXT.LINK p MORE

2 Press [F2](OFFSET) key. [F2]

OFFSET MEASUREMENT 1.ANGLE OFFSET 2.DIST. OFFSET 3.PLANE OFFSET 4.COLUMN OFFSET

3 Press [F1](ANGLE OFFSET) key. [F1]

ANGLE OFFSET 1.FREE V-ANGLE 2.HOLD V-ANGLE

Prism P · Prism height · Instrument height

Page 74 of the Topcon GTS-822A user manual — A 0
Page 74 · click to enlarge
Page 74

5 PROGRAM MODES

4 Select the vertical angle [FREE] or [HOLD]. *1) [F1]or [F2]

ANGLE OFFSET

HDm MEAS HT

5 Collimate prism P, and press the [F1](MEAS) key. *1)

ANGLE OFFSET

P [F1]

HD* < m MEAS HT

The horizontal distance from the instrument to the prism will be measured.

ANGLE OFFSET HR20°30'40" HD: 20.000 m VD: 0.000 m NEXT SD NEZ REC

6 Collimate point A0 using the horizontal motion clamp and horizontal tangent screw.

ANGLE OFFSET HR30°00'00" HD: 20.000 m VD: 0.000 m NEXT SD NEZ REC

A 0

7 To show the slope distance of point A0, press the [F2](SD) key.

ANGLE OFFSET V90°00'00" HR: 30°00'00" SD: 20.000 m NEXT HD NEZ REC

8 To show the coordinates, press the [F3](NEZ) key. *2)

ANGLE OFFSET N17.321 m E : 10.000 m Z : 0.000 m NEXT SD HD REC

*1) To set the prism height or instrument height, press the [F5](HT) key. *2) To repeat angle offset measurement, press the [F1](NEXT) key. The display will return to step 5.

Collimate · Collimate

Page 75 of the Topcon GTS-822A user manual — OK INP
Page 75 · click to enlarge
Page 75

5 PROGRAM MODES

5.6.2 Distance Offset Measurement The measurement of a place apart from a prism is possible by inputting offset horizontal distance of front and back / right and left.

A 0 oHD sign

A 1

Occ.Point

When measuring coordinates of ground point A1: Set the instrument height / prism height.

When measuring coordinates of point A0: Set the instrument height only.

(Set the prism height to 0 ).

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

1 Press [F6](MORE) key from programs menu to get to the next page of programs.

Programs F1 LINE p 7/7 F2 OFFSET p F3 EXT.LINK p MORE

2 Press [F2](OFFSET) key. [F2]

OFFSET MEASUREMENT 1.ANGLE OFFSET 2.DIST. OFFSET 3.PLANE OFFSET 4.COLUMN OFFSET

3 Press [F2](DIST. OFFSET) key.

DIST. OFFSET dFR0.000 m dRL : 0.000 m

Previous offset value screen will appear. dFR: Forward/Rear offset value dRL: Right/Left offset value

OK INP

Show 5 more labels / short text on this page
Forward HD · RorL HD · Prism height · Prism P · Instrument height
Page 76 of the Topcon GTS-822A user manual — DIST. OFFSET
Page 76 · click to enlarge
Page 76

5 PROGRAM MODES

4 If you reset the offset value, press the [F6](INP) key and input the value. *1)

DIST. OFFSET dFR0.000 m dRL : 0.000 m

EXIT BS

5 Collimate prism using the horizontal motion clamp and horizontal tangent screw. Press the [F1](MEAS) key. *2)

DIST. OFFSET

P [F1]

HDm MEAS HT

The offset measurement data will be shown.

DIST. OFFSET HR30°00'00" HD: 20.000 m VD: 0.000 m NEXT SD NEZ REC

6 To show the slope distance of point A0, press the [F2](SD) key.

DIST. OFFSET V90°00'00" HR: 30°00'00" SD: 20.000 m NEXT HD NEZ REC

7 To show the coordinates, press the [F3](NEZ) key. *3)

DIST. OFFSET N17.321 m E : 10.000 m Z : 0.000 m NEXT SD HD REC

*1) To skip the input, press the [F1](OK) key. *2) To set the prism height or instrument height, press the [F5](HT) key. *3) To repeat the offset measurement, press the [F1](NEXT) key. The display will return to step 5.

Collimate

Page 77 of the Topcon GTS-822A user manual — P
Page 77 · click to enlarge
Page 77

5 PROGRAM MODES

5.6.3 Plane Offset Measurement Measuring will be taken for the place where direct measuring can not be done, for example distance or coordinate measuring for a edge of a plane. Three random target points (P1, P2, P3) on a plane will be measured at first in the plane offset measurement to determine the measured plane. Collimate the measuring target point (P0) then the instrument calculates and displays coordinate and distance value of cross point between collimation axis and of the plane.

P

P

P 2 3 P

Target heights of P1 to P3 is set to zero automatically.

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

1 Press [F6](MORE) key from programs menu to get to the next page of programs.

Programs F1 LINE p 7/7 F2 OFFSET p F3 EXT.LINK p MORE

2 Press [F2](OFFSET) key. [F2]

OFFSET MEASUREMENT 1.ANGLE OFFSET 2.DIST. OFFSET 3.PLANE OFFSET 4.COLUMN OFFSET

3 Press [F3](PLANE OFFSET) key.

PLANE OFFSET N001# SDm MEAS HT

Measurement screen of three points on a plane will be shown.

Show 4 more labels / short text on this page
Edge (Prism) · (Point without prism) · (Prism) · (Prism)
Page 78 of the Topcon GTS-822A user manual — P0
Page 78 · click to enlarge
Page 78

5 PROGRAM MODES

4 Collimate prism P1, and press the [F1](MEAS) key. Measuring will start. After measuring, the second point measurement screen will be shown.

PLANE OFFSET N002# SDm MEAS HT

P1 [F1]

5 Measure the second and third prism in the same way. *1)

PLANE OFFSET N003# SDm MEAS HT

P3 [F1]

The instrument calculates and displays coordinate and distance value of cross point between collimation axis and of the plane. *2)

PLANE OFFSET HR85°30'40" HD: 54.321 m VD: 10.000 m NEXT SD NEZ REC

6 Collimate point P0 on the plane using the horizontal motion clamp and horizontal tangent screw.

PLANE OFFSET HR75°30'40" HD: 54.600 m VD: -0.487 m NEXT SD NEZ REC

P0

P0 data will be shown.

7 To show the slope distance of point P0, press the [F2](SD) key.

PLANE OFFSET V90°30'30" HR: 75°30'40" SD: 54.602 m NEXT HD NEZ REC

8 To show the coordinates, press the [F3](NEZ) key. *3),4)

PLANE OFFSET N17.321 m E : 10.000 m Z : 20.000 m NEXT SD HD REC

*1) In case the calculation of plane was not successful by the measured three points, error displays. Start measuring over again from the first point. *2) Error will be displayed when collimated to the direction which does not cross with the determined plane. *3) The reflector height of the target point P0 is set to zero automatically. *4) To repeat the offset measurement, press the [F1](NEXT) key. The display will return to step 4.

Show 4 more labels / short text on this page
Collimate · Collimate · P2 [F1] Collimate · Collimate
Page 79 of the Topcon GTS-822A user manual — P1 [F1]
Page 79 · click to enlarge
Page 79

5 PROGRAM MODES

5.6.4 Column Offset Measurement If it is possible to measure circumscription point (P1) of column directly, the distance to the center of the column (P0), coordinate and direction angle can be calculated by measured circumscription points (P2) and (P3). The direction angle of the center of the column is 1/2 of total direction angle of circumscription points (P2) and (P3).

P P

P

3 P

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

1 Press [F6](MORE) key from programs menu to get to the next page of programs.

Programs F1 LINE p 7/7 F2 OFFSET p F3 EXT.LINK p MORE

2 Press [F2](OFFSET) key. [F2]

OFFSET MEASUREMENT 1.ANGLE OFFSET 2.DIST. OFFSET 3.PLANE OFFSET 4.COLUMN OFFSET

3 Press [F4](COLUMN OFFSET) key.

COLUMN OFFSET Center HDm MEAS HT

Measurement screen of the center of a column will be shown.

4 Collimate the center of the column (P1) and press the [F1](MEAS) key. Measuring will start. After the measurement, angle measuring display of the left side (P2) will be shown.

COLUMN OFFSET Left HR9 0°30'40" SET

P1 [F1]

Prism · Collimate

Page 80 of the Topcon GTS-822A user manual — P3 [F6]
Page 80 · click to enlarge
Page 80

5 PROGRAM MODES

5 Collimate the left side of the column (P2) and press the [F6](SET) key.

COLUMN OFFSET Right HR95 °30'40" SET

P2 [F6]

After the measurement, angle measuring display of the right side (P3) will be shown.

6 Collimate the right side of the column (P3) and press the [F6](SET) key.

COLUMN OFFSET HR90°30'40" HD: 10.321 m VD: 0.886 m NEXT SD NEZ REC

P3 [F6]

After the measurement, the distance between the instrument and center of the column (P0) will be calculated and displayed.

7 To show the slope distance of point P0, press the [F2](SD) key.

COLUMN OFFSET V85°30'30" HR: 90°30'40" SD: 10.999 m NEXT HD NEZ REC

8 To show the coordinates, press the [F3](NEZ) key. *1)

COLUMN OFFSET N17.321 m E : 10.962 m Z : 0.886 m NEXT SD HD REC

*1) To repeat the offset measurement, press the [F1](NEXT) key. The display will return to step 4.

Collimate · Collimate

Page 81 of the Topcon GTS-822A user manual — CABLE/RADIO MODEM/RC CABLE
Page 81 · click to enlarge
Page 81

5 PROGRAM MODES

5.7 External Link

You can use compatible communication command of AP-L1A for GTS-820A series. In this process carry out setting for remote control system RC-2II using together.

5.7.1 Starting compatible communication program of AP-L1A

Programs F1 BS p 4/7 F2 STORE p F3 REM p F4 MLM p MORE

1 Press the [F6](MORE) key to get the next page.

Programs F1 LINE P 7/7 F2 OFF SET P F3 EXT.LINK P MORE

2 Press the [F3](EXT.LINK) key. The compatible program EXTERNAL LINK will start.

EXTERNAL LINK 1 Execute 2 Setting

5.7.2 Setting for the communication Decide transmit course and parameters before executing communication.

(1)Setting communication course Select a communication course according to the using optional device.

1. Cable : In case connecting personal computer or other than Topcon's designated wireless modem to the RS-232C connector. 2) RADIO MODEM : In case connecting Topcon's designated wireless modem. 3) RC :In case carrying out optical communication using with the remote controller system RC-2II.

Execute Section 5.7.1“Starting compatible communication program of AP-L1A” to start [EXT.LINK] of compatible communication program of AP-L1.

EXTERNAL LINK 1 Execute 2 Setting

1 Press the [F2](Setting) key. [F2]

Setting 1 CABLE/RADIO MODEM/RC 2 PARAMETER(CABLE) 3 PARAMETER(RC) 4 PARAMETER(RADIO MODEM)

2 Press the [F1] key to select [CABLE/RADIO MODEM/RC]

CABLE/RADIO MODEM/RC CABLE

SET ↑ ↓ EXIT

Page 82 of the Topcon GTS-822A user manual — CABLE/RADIO MODEM/RC RC
Page 82 · click to enlarge
Page 82

5 PROGRAM MODES

3 Select communication course by pressing the [F3](↑) or [F4](↓) key. (Sample setting :RC)

CABLE/RADIO MODEM/RC RC

SET ↑ ↓ EXIT

4 Press the [F1](SET) key to decide. [F4]

Setting 1 CABLE/RADIO MODEM/RC 2 PARAMETER(CABLE) 3 PARAMETER(RC) 4 PARAMETER(RADIO MODEM)

l To cancel the setting, press the [F6](EXIT)key or the [ESC] key.

(2)Setting Parameters of Cable (RS-232C) In case connecting Topcon's designated wireless modem, simply select communication course as "RADIO MODEM" it is enough to do setting of parameter automatically. In case connecting personal computer or other than Topcon's designated wireless modem, it is required to do parameters setting for RS-232C before using.

Parameters 1) SPEED (Baud rate) Sets communication speed Set items: 1200, 2400, 4800, 9600bps

2. BIT FORMAT Select the communication format. Set items:

Bit length : 7 : D7, 8 : D8 Stop bit : 1 : S1, 2 : S2 Parity bit : NONE, ODD, EVEN

3. DELIMITER (Terminate) Selecting CR (Carriage return), or LF (Line feed) will be added at the end of data. Set items:

ETX, ETX+CR, ETX+CRLF 4) RTS (Control of signal line) Select default output of signal line Set items:

Hi : High level (Normal) Low : Low level (It becomes High level only when data are transmitted.)

5. REC TYPE Select the option to record the data for the distance measurement.

REC-A : Measure the distance again and record the updated distance. REC-B : Record the data for the last distance measurement on the display.

Execute Section 5.7.1“Starting compatible communication program of AP-L1A” to start [EXT.LINK] of compatible communication program of AP-L1.

EXTERNAL LINK 1 Execute 2 Setting

1 Press the [F2](Setting) key. [F2]

Setting 1 CABLE/RADIO MODEM/RC 2 PARAMETER(CABLE) 3 PARAMETER(RC) 4 PARAMETER(RADIO MODEM)

or [F4]

Page 83 of the Topcon GTS-822A user manual — ETX, ETX+CR, ETX+CRLF
Page 83 · click to enlarge
Page 83

5 PROGRAM MODES

2 Press the [F2] key to select [2PARAMETER (CABLE)]. Speed setting screen will appear.

SPEED

SET ↑ ↓ EXIT

3 Press the [F3](↑) or [F4](↓) key to select baud rate then press the [F1](SET) key to decide.

BIT FORMAT

D8 S1 NONE

SET ↑ ↓ EXIT

4 Set bit format in the same way. [F3]

TERMINATE

ETX

SET ↑ ↓ EXIT

5 Set DELIMITER (Terminate) in the same way. [F3]

RTS

SET ↑ ↓ EXIT

6 Set RTS in the same way. 7 Set REC TYPE in the same way.

REC TYPE

REC-A

SET ↑ ↓ EXIT

Setting 1 CABLE/RADIO MODEM/RC 2 PARAMETER(CABLE) 3 PARAMETER(RC) 4 PARAMETER(RADIO MODEM)

l To cancel the setting, press the [F6](EXIT)key or the [ESC] key.

(3)Setting Parameters of RC Set the paameters forcommunication with remote controller system. Parameters 1) Channel Sets communication channel The same channel must be set for GTS-820A series and RC-2RII. Set channels : 1, 2, 3

2. DELIMITER (Terminate) Selecting CR (Carriage return), or LF (Line feed) will be added at the end of data. Set items:

ETX, ETX+CR, ETX+CRLF

3. Retry This is a method to retry setting for sending data during communication with remote controller RC2RII. Set items:

Standard: Gives good for fast communication.

This is offered in normal condition. Divided: Using in bad condition such in long distance, bad condition of sight, strong

Show 6 more labels / short text on this page
or [F4] [F1] · or [F4] [F1] · or [F4] [F1] · Hi · or [F4] [F1] · Standard, Divided
Page 84 of the Topcon GTS-822A user manual — REC TYPE
Page 84 · click to enlarge
Page 84

5 PROGRAM MODES

heat simmer, or happens cut off the optical path, in such cases it takes long time for communication or results failure. You are offered to set [Divided] item. 4) REC TYPE Select the option to record the data for the distance measurement.

REC-A : Measure the distance again and record the updated distance. REC-B : Record the data for the last distance measurement on the display.

Execute Section 5.7.1“Starting compatible communication program of AP-L1A” to start [EXT.LINK] of compatible communication program of AP-L1.

EXTERNAL LINK 1 Execute 2 Setting

1 Press the [F2](Setting) key. [F2]

Setting 1 CABLE/RADIO MODEM/RC 2 PARAMETER(CABLE) 3 PARAMETER(RC) 4 PARAMETER(RADIO MODEM)

2 Press the [F3] key to select [3 PARAMETER (RC)].

CHANNEL 1

SET ↑ ↓ EXIT

3 Select a channel by pressing the [F3](↑) or [F4](↓) key then press the [F1](SET) key.

TERMINATE ETX

SET ↑ ↓ EXIT

4 Select Terminate by pressing the [F3](↑) or [F4](↓) key then press the [F1](SET) key.

SET ↑ ↓ EXIT

5 Select Retry by pressing the [F3](↑) or [F4](↓) key then press the [F1](SET) key

REC TYPE

REC-A

SET ↑ ↓ EXIT

6 Set REC TYPE in the same way. [F3]

Setting 1 CABLE/RADIO MODEM/RC 2 PARAMETER(CABLE) 3 PARAMETER(RC) 4 PARAMETER(RADIO MODEM)

l To cancel the setting, press the [F6](EXIT)key or the [ESC] key.

(4)Setting Parameters for Radio Modem Set the parameters for Radio Modem.

Parameters 1) Channel (Only for certain market) Sets communication channel The same channel must be set for GTS-820A series and Radio Modem.

Show 5 more labels / short text on this page
or [F4] [F1] · RETRY Standard · or [F4] [F1] · or [F4] [F1] · or [F4] [F1]
Page 85 of the Topcon GTS-822A user manual — 5.7.3 Carrying out Communication
Page 85 · click to enlarge
Page 85

5 PROGRAM MODES

Set channels : A, B, C

2. REC TYPE Select the option to record the data for the distance measurement.

REC-A : Measure the distance again and record the updated distance. REC-B : Record the data for the last distance measurement on the display.

Execute Section 5.7.1“Starting compatible communication program of AP-L1A” to start [EXT.LINK] of compatible communication program of AP-L1.

EXTERNAL LINK 1 Execute 2 Setting

1 Press the [F2](Setting) key. [F2]

Setting 1 CABLE/RADIO MODEM/RC 2 PARAMETER(CABLE) 3 PARAMETER(RC) 4 PARAMETER(RADIO MODEM)

2 Press the [F4] key to select PARAMETER (RADIO MODEM). (The channel setting display is provided only for certain market)

CHANNEL A

SET ↑ ↓ EXIT

REC TYPE

REC-A

SET ↑ ↓ EXIT

3 Set REC TYPE in the same way.

Setting 1 CABLE/RADIO MODEM/RC 2 PARAMETER(CABLE) 3 PARAMETER(RC) 4 PARAMETER(RADIO MODEM)

5.7.3 Carrying out Communication

EXTERNAL LINK 1 Execute 2 Setting

Execute Section 5.7.1“Starting compatible communication program of AP-L1A” to start [EXT.LINK] of compatible communication program of AP-L1.

1 Press the [F1](Execute) key. The display as showing right says the compatible communication program of AP- L1A is executed and communication command can be accepted.

EXTERNAL LINK (RC) Remote control is being done from the controller. EXIT

l To stop the communication, press the [F6](EXIT) or [ESC] key.

or [F4] [F1] · or [F4] [F1]

Page 86 of the Topcon GTS-822A user manual — 6.1 View Internal Memory and Card Memory Status
Page 86 · click to enlarge
Page 86

6 MEMORY MANAGE MODES 6 MEMORY MANAGE MODES

2003-10-10 15:30:40

[Press [F3] key.]

Prog Std Mem Comm Adj Para

MEMORY MANAGE MODES The following items are available in this mode. 1. Display the memory size and memory free. 2. Protecting files 3. Delete files 4. Rename files 5. Copy files 6. Initialize memory.

Memory manage F1 Internal memory F2 Card memory

6.1 View Internal Memory and Card Memory Status

When selecting the internal memory or card memory, the GTS-820 will display the memory size, the amount of free memory and the expiration date for the internal lithium battery. The display information format is the same for the card memory except that the card name appears at the top of the display. The card name can be eleven characters in length, alpha or numeric.

Memory manage F1 Internal memory F2 Card memory

1 Select Internal memory or Card memory by pressing [F1] or [F2] key. The memory capacity and the remaining memory capacity are shown. Example: Internal Memory

Memory size 1967KByte Memory free 1951KByte Battery expire 2004/01 Init. File

2 Press [F6](File) key. Each File status (File name, File name extension, Used memory capacity, Date) are shown. Press the [ESC] key to return to the main menu icons.

JIS .DAT 1597 12-25 TOPCON .DAT 1089 10-05 FC7 .TXT 2450 09-11 HILL .DAT 31777 08-19 Pro Ren Del Copy ↑ ↓

Page 87 of the Topcon GTS-822A user manual — [ENT]
Page 87 · click to enlarge
Page 87

6 MEMORY MANAGE MODES

6.2 Protect a File

Protecting one or more files can be accomplished with the file protection mode. When a file is protected, an asterisk appears after the file name extension. If a file is protected, you can not delete the file unless you remove the file protection. l Note:All the files stored will be erased by initializing the memory, even if the files are protected.

1 Proceed Chapter 6.1.

JIS .DAT 1597 12-25 TOPCON .DAT 1089 10-05 FC7 .TXT 2450 09-11 HILL .DAT 31777 08-19 Pro Ren Del Copy ↑ ↓

2 Select a file using [F5](↑) key or [F6](↓) key.

3 Press [F1](Pro) key.

[TOPCON .DAT] ON OFF

4 Press [F5](ON) key. *1) The file is protected and display will return to file name.

*1) When you cancel the protection, repeat the procedure above mentioned and select [F6](OFF) key.

6.3 Rename a File

Files can be renamed on the card or in internal memory. When renaming a file, the old file name appears above the input line for the new file name. When typing in the new name, you do not have to input the file extension.

1 Proceed Chapter 6.1.

JIS .DAT 1597 12-25 TOPCON .DAT 1089 10-05 FC7 .TXT 2450 09-11 HILL .DAT 31777 08-19 Pro Ren Del Copy ↑ ↓

2 Select a file using [F5](↑) key or [F6](↓) key. Select a

3 Press [F2](Ren) key. [F2]

Rename Old name [TOPCON .DAT] New name [ ] Alpha SPC ← →

4 Enter a new file name within 8 characters. Press [ENT] key. *1)

[ENT]

*1) Refer to Chapter 2.9 “How to Enter Numerals and Alphabet Letters” .

Show 5 more labels / short text on this page
Select a · file · Protect · file · Enter name
Page 88 of the Topcon GTS-822A user manual — [HILL .DAT] YES NO
Page 88 · click to enlarge
Page 88

6 MEMORY MANAGE MODES

6.4 Deleting a File

The delete mode erases a file from internal memory or the card memory. If a file is protected, the file can not be erased. File protection must be removed before you can delete a file. Only one file can be erased at a time.

1 Proceed Chapter 6.1.

JIS .DAT 1597 12-25 TOPCON .DAT 1089 10-05 FC7 .TXT 2450 09-11 HILL .DAT 31777 08-19 Pro Ren Del Copy ↑ ↓

2 Select a file using [F5](↑) key or [F6](↓) key. Select a

3 Press [F3](Del) key.

[TOPCON .DAT] YES NO

4 Confirm the file name, and press [F5](YES) key.

l If the file is protected, the file can not be erased. Erase the file after canceling the protection.

6.5 Copy a File

A file can be copied from internal memory to the card memory and vice verse. The copy mode only copies files to the root directory. Files can not be copied into other directories. Example : Copying a file in internal memory to card memory.

MEMORY manage F1 Internal memory F2 Card memory

1 Press [F1] key to choose Internal memory.

JIS .DAT 1597 12-25 TOPCON .DAT 1089 10-05 FC7 .TXT 2450 09-11 HILL .DAT 31777 08-19 Pro Ren Del Copy ↑ ↓

2 Select a file using [F5](↑) key or [F6](↓) key.

3 Press [F4](Copy) key. [F4]

[HILL .DAT] YES NO

4 Confirm the file name, and press [F5](YES) key.

Show 5 more labels / short text on this page
file · Delete · Select a · file · File Copy
Page 89 of the Topcon GTS-822A user manual — YES NO
Page 89 · click to enlarge
Page 89

6 MEMORY MANAGE MODES

6.6 Initializing Memory

The initialize memory option will erase ALL FILES in either the internal memory or card memory and files cannot be retrieved. Example: Initializing card memory

MEMORY manage F1 Internal memory F2 Card memory

1 Press [F2] key to select card memory. [F2]

Card name [TOPCON ] Memory size 1967KByte Memory free 1951KByte Card battery expire 11/99 Init File

2 Press [F1](Init) key. [F1]

RAM card memory format

YES NO

3 Confirm the display, and press [F5](YES) key. Initializing will be executed.

[ ] Alpha SPC ← →

4 Input card name and press [ENT] key.

Card memory expire Today 2003-11 Validity +4.0 year Until 2007-11 YES NO

Card memory expire will be shown.

5 Confirm the display, and press [F5](YES) key. *1)

The display returns to main menu.

*1) To reset the card memory expire, press [F6] (NO) key and input new data.

Card name · Card name [ENT]

Page 90 of the Topcon GTS-822A user manual — [ENT]
Page 90 · click to enlarge
Page 90

7 COMMUNICATION MODES 7 COMMUNICATION MODES

2003-10-10 15:30:40

[Press [F4] key.]

Prog Std Mem Comm Adj Para

COMMUNICATION MODES

The communication modes are used for setting the Baud rate (Protocol), receiving a file (Data file in) and sending a file (Data file out). A data transfer program on your PC that supports (YMODEM) will be necessary to send or receive data files.

Communication F1 Protocol F2 Data file in F3 Data file out

7.1 Setting of PROTOCOL

To transfer data files to and from the GTS-820A Series and PC, the Baud rates must be the same. The Baud rate selections are 600, 1200, 2400, 4800, 9600, and 19200.

To set the protocol for measured data transferring, refer to Chapter 8 “PARAMETERS SETTING MODE” ..

Communication F1 Protocol F2 Data file in F3 Data file out

1 Press the [F1](Protocol) key for protocol. [F1]

Communication Speed 600 1200 2400 4800 9600 19200 ← → ↑ ↓

2 To select the Baud rate, use the arrow key`s [F3-F6] to highlight your choice. When the correct Baud rate is highlighted, press the [ENT] key.

Communication F1 Protocol F2 Data file in F3 Data file out

[ENT]

[F3] to[F6]

Page 91 of the Topcon GTS-822A user manual — [ENT]
Page 91 · click to enlarge
Page 91

7 COMMUNICATION MODES

7.2 Data File In

When transferring data files from a PC to the GTS-820A Series, the file received into the main directory. Data files CANNOT be received into a subdirectory. Data files CANNOT be transferred to the card memory. Files can only be transferred to the internal memory and then copied onto the card.

Communication F1 Protocol F2 Data file in F3 Data file out

Make sure the instrument is ready and waiting for the data file before you command the PC to send the file.

1 Press [F2](Data file in) key. 2 Command the PC to send the file at this time. File name, amount of received data (Byte) / Capacity of the file (Byte) and percentage of proceeding will be displayed. When the transfer is complete, the display will return to the main menu icons.

Data file in [TOPCON .DAT]

7.3 Data File Out

Transferring a file from the GTS-820A internal memory or card memory to the PC is also possible.

Make sure the PC is ready and waiting before the GTS-820 sends the file.

Communication F1 Protocol F2 Data file in F3 Data file out

1 Press [F3](Data file out) key. [F3]

Data file out F1 Internal memory F2 Card memory

2 Press [F1](Internal memory) or [F2](Card memory) key and press [ENT] key. Example: Internal memory

JIS .DAT 1597 12-25 TOPCON .DAT 1089 10-05 FC7 .TXT 2450 09-11 HILL .DAT 31777 08-19 Data file out ↑ ↓

[ENT]

3 Select a file by pressing [F5](↑) or [F6](↓) key and press [ENT] key. File name, amount of sent data(Byte) / Capacity of the file (Byte) and percentage of proceeding will be displayed. When the transfer is complete, the display will returns to the file menu.

Data file out [TOPCON .DAT]

Show 5 more labels / short text on this page
0/ 8676 (0%) · [F1] to[F2] · Select · a file [ENT] · 0/ 1089 (0%)
Page 92 of the Topcon GTS-822A user manual — 8.1.1 Parameters for Measurement and Display
Page 92 · click to enlarge
Page 92

8 PARAMETERS SETTING MODE 8 PARAMETERS SETTING MODE

2003-10-10 15:30:40

[Press [F6] key.]

Prog Std Mem Comm Adj Para

PARAMETERS SETTING MODE

In this mode, setting of parameters regard with measuring, displaying and communications will be done. When a parameter is changed and set, the new value is stored into memory. Press [F6] key from the main menu icons, the following display will be shown. The parameter modes is classified in Measurement and Communication.

Parameters F1 Measurement F2 Communication F3 Password

8.1 Parameter Setting Options

8.1.1 Parameters for Measurement and Display

Menu Selecting Item Contents

Ang. Unit deg / gon / mil Select degree(360°), gon(400G) or mil (6400M) for the measuring angle unit to be shown on the display.

Select the minimum display angle reading ON or OFF. GTS-821A [ OFF:1" / ON:0.5" ] GTS-822A [ OFF:1" / ON:0.5" ] GTS-823A [ OFF:5" / ON:1" ] GTS-825A [ OFF:5" / ON:1" ]

Min.Angle OFF / ON

Tilt OFF / 1axis / 2axes Select the tilt sensor option for OFF, (1axis) vertical only or (2axes) vertical and horizontal.

Select the error correction ON or OFF for collimation and error adjustment. Note: Perform this item after complete section 9.4. For more information, refer to Section 9.4 “Adjustment of Compensation Systematic Error of Instrument” and Section 9.5 “Showing Constant List and Switch ON/OFF Compensation Systematic Error of Instrument” .

Err. corr. OFF / ON

V -0 Zenith / Level Select the vertical angle reading for Zenith 0 or Horizontal 0.

It is able to retain presetting angle after turning power off.(MEMORY) Note: After changing this parameter, turn the power switch off once.

HAmem OFF / MEM. ON

Select the stopping accuracy of automatic rotation to required angle. Fine:3" Normal :5" Coarse:10"

Turn Fine / Normal / Coarse

Auto.Aim Fine / Normal / Coarse Select the accuracy of automatic collimation.

Page 93 of the Topcon GTS-822A user manual — 8 PARAMETERS SETTING MODE
Page 93 · click to enlarge
Page 93

8 PARAMETERS SETTING MODE

Dist. Unit METER /FEET Select the distance measuring unit Meter or Feet shown on the display.

Select the meter / feet conversion factor. US SURVEY feet

C.F. m/ft Us.f /Intl.f

1m =3.280833333333333 ft. INTERNATIONAL feet

1m =3.280839895013123 ft.

Min. Dist. OFF / ON Select OFF or ON for the minimum distance in fine mode. OFF:1mm :ON: 0.2mm

S/A buzz. OFF / ON Select the Audio tone OFF or ON for the Set Audio Mode.

Select the coefficient correction for refraction and earth curvature. Selections for the refraction coefficient are; OFF (No correction), K=0.14 or K=0.20.

W-corr. OFF/ 0.14 / 0.20

N/E/Z mem OFF / MEM.ON Select the option to store the coordinates (NEZ) for the occupied point when power is turned off.

N/E- ord. NEZ / ENZ Select the display format in the coordinate measurement mode for NEZ or ENZ.

Temp. Unit °C / °F Select the temperature unit for the atmospheric correction.

Pres. Unit mmHg/inHg/hPa Select the air pressure unit for the atmospheric correction .

Prohibit switching angle right or left by soft key in angle measurement mode OFF : Switching is possible ON : Prohibition

R/L Lock OFF / ON

m/ft Lock OFF / ON Prohibit switching meter unit or feet unit. OFF : Switching is possible ON : Prohibition

d / m / y m / d / y y /m / d

Select the date format shown on the display. (Month / Date / Year) , (Date/Month/ Year) or (Year / Month / Date)

A. P. OFF OFF / ON (01 to 99) The auto power off function can be turned OFF or set ON. OFF : not use ON :1 to 99 minutes (numeric key)

Heater OFF / ON The heater option for both display units can be turned OFF or ON.

EDM cut off time after distance measurement is completed can be changed. OFF : EDM is cut off immediately after measuring ON : EDM is cut off after 1 to 99 minutes.

EDM wait OFF / ON (01 to 99)

Select the initial mode when powering on. Menu : Menu Std : Standard measurement E.Link : External link

Ini. mode Menu / Std / E.Link

Self chk OFF / ON Select the self check function ON or OFF when powering on.

Date

Page 94 of the Topcon GTS-822A user manual — RC S / M
Page 94 · click to enlarge
Page 94

8 PARAMETERS SETTING MODE

8.1.2 Parameters for communication

The following settings are effective for standard measurement modes only. You are requested to set each time of each application such as EXTERNAL LINK (in Program modes) or other application software.

Serial port.

Menu Selecting Item Contents

S.Port RS232C /RC Selecting serial port, RS-232C connector 1(6pins) or Remote controll system.

Setting parameters for RS232C

Menu Selecting Item Contents

B. Rate 1200 / 2400 / 4800 / 9600 Select the baud rate.

Data. L 7 / 8 Select the data length seven digits or eight digits.

Parity none / odd / even Select the parity bit.

Stop Bit 1 / 2 Select the stop bit.

Delimit ETX / CRLF Select the option OFF or ON for carriage return and line feed when collecting measurement data with a computer.

Select the option to record the data. REC-A : The measurement is started and new data is output. REC-B : The data being displayed is output.

REC-A/B A / B

When communicating to an external device, the protocol for handshaking can omit the [ACK] coming from the external device so data is not sent again. OFF : Omit the [ACK] ON : Standard

Protocol OFF / ON

NEZ-REC Std / Exp Record coordinates in standard or Data with slope distance and horizontal angle data.

Selecting additional information of utility to measuring data such as tracking status or not. If such utility is selected, electric circular level graphic will not be displayed whenever tilted over. OFF :No additional information ON :Additional information

Trk Stat OFF / ON

Setting parameter for RC

Menu Selecting Item Contents

Channel 1 / 2 / 3 Sets communication channel when using with remote controll system.

Selecting the vertical range for searching a prism when using with remote controll system. 15 : ±15° 30 : ±30°

V.Search 15 / 30

Selecting the number of the RC-2RII to use one or more than one when using with RC-2RII. S : Single RC-2RII use M : Multiple RC-2RII use

RC S / M

Page 95 of the Topcon GTS-822A user manual — REC-A/B A / B
Page 95 · click to enlarge
Page 95

8 PARAMETERS SETTING MODE

Selecting the method of the data re-transmitting. Std (Standard) : This is offered in normal condition. Div.(Divided) : Using in bad condition such in long

Retry Std. / Div.

distance, bad condition of sight, strong heat simmer.

Delimit ETX / CRLF Select the option OFF or ON for carriage return and line feed when collecting measurement data with a computer.

Select the option to record the data. REC-A :The measurement is started and new data is output. REC-B :The data being displayed is output.

REC-A/B A / B

NEZ-REC Std / Exp Record coordinates in standard or Data with slope distance and horizontal angle data.

Selecting additional information of utility to measuring data such as tracking status or not. If such utility is selected, electric circular level graphic will not be displayed whenever tilted over. OFF :No additional information ON :Additional information

Trk State OFF / ON

B. Rate 4800 Fixed

Data. L 8 Fixed

Stop Bit 1 Fixed

Parity none Fixed

Page 96 of the Topcon GTS-822A user manual — YES NO
Page 96 · click to enlarge
Page 96

8 PARAMETERS SETTING MODE

8.2 Setting Parameters

8.2.1 Parameters for Measurement and Display

[Example setting] S/A BUZZEROFF, Atmospheric pressure: hPa

1 Press the [F6] key from the main menu icons. [F6]

Parameters F1 Measurement F2 Communication F3 Password

2 Press the [F1] (Measurement) key. [F1]

Parameters (Measurement) Ang.Unit [ deg ] gon mil Min.Angl OFF [ ON ] Tilt [ OFF ] 1axis 2axis SET EXIT <- -> ↑ ↓

3 Select the menu by pressing [F6](↓) key. (Example: S/A buzz.))

Parameters (Measurement) S/A buzz. OFF [ ON ] W-corr. OFF [ 0.14 ] 0.20 N/E/Z mem OFF [ ON ] SET EXIT <- -> ↑ ↓

4 Press [F3](←) key, and select OFF. [F3]

Parameters (Measurement) S/A buzz.[ OFF ] ON W-corr. OFF [ 0.14 ] 0.20 N/E/Z mem OFF [ ON ] SET EXIT <- -> ↑ ↓

5 Select the atmospheric pressure menu by pressing [F6](↓) key.

Parameters (Measurement) Pres.Unit [ mmHg ] inHg hPa R/L Lock [ OFF ] ON m/ftLock [ OFF ] ON SET EXIT <- -> ↑ ↓

6 Press [F4](→) key twice, and select hPa. [F4]

Parameters (Measurement) Pres.Uni mmHg inHg [hPa ] R/L Lock [ OFF ] ON m/ftLock [ OFF ] ON SET EXIT <- -> ↑ ↓

7 Press [F1](SET) key. [F1]

YES NO

8 Press [F5](YES) key. *1) The display returns main menu.

*1) To cancel the setting, press [F6](NO) key.

Parameters (Measurement) · > Set OK?

Page 97 of the Topcon GTS-822A user manual — EXIT CHANGE ON OFF
Page 97 · click to enlarge
Page 97

8 PARAMETERS SETTING MODE

8.2.2 Parameters for Communication Sample setting: RS232C

1 Press the [F6] key from the main menu icons. [F6]

Parameters F1 Measurement F2 Communication F3 Password

2 Press the [F2] (Communication) key. The screen in the right is indicated.

Parameters (Communication) 1 Serial Port RS232C/RC 2 Set RS232C 3 Set RC

3 Press the [F2](Set RS232C) key. The next steps are same as Section 8.2.1- Parameters Setting for communication, refer to the section 8.2.1.

Parameters (Communication) B.Rate [1200] 2400 4800 9600 Data.L [ 7 ] 8 Parity none odd [even] SET I.GTS <- -> ↑ ↓

l The setting will reset to the default settings by pressing the [F2](I.GTS) key. (1200baudrate, Even, Stop 1, Delimit ETX, Rec-A Protocol ON, NEZ-REC Standard) Factory default settings are indicated with underlines in Chapter 8.1.2 “Parameters for communication” . l In the setting of RC, the settings of Baudrate, data length, Parity and Stop are fixed. They will be indicated on the screen for your reference. Though Protocol is not indicated, it is fixed to OFF.

8.2.3 Password Option Establishing a Password A password can be set in the GTS-820A series to secure the use of the instrument. Once a password is established the user can disable the option or change the password. Once a password established and the option is turned off, the password will always remain in memory. When turning on the instrument after a password-input screen appears before the self-test mode. Type in your password and press the [ENTER] to continue. A maximum of 10 numeric digits can be entered for a password. All zeros (0000000000) or 9`s (9999999999) are invalid passwords. If 10 unsuccessful attempts are made to input a password, the instrument will shut off automatically. Establishing a Password for the first time. The instructions below show how to establish a password for the first time.

1 From the main menu icons, press [F6](Para) to access the parameters option menu. To access the password option, press [F3](Password).

Parameters F1 Measurement F2 Communication F3 Password

EXIT CHANGE ON OFF

Password [OFF]

Page 98 of the Topcon GTS-822A user manual — [ENT]
Page 98 · click to enlarge
Page 98

8 PARAMETERS SETTING MODE

2 The password option screen will appear. When accessing the password option for the first time, the [OFF] indicator will appear on the upper left corner of the screen. To establish a password you can press the [F5](ON) key to turn on the option and establish a password. 3 The password-input screen will appear. At the blinking cursor type in your password and press the [ENT] key.

Password Input a password [ ]

EXIT BS

Password Input again (confirmation) [ ]

EXIT BS

[ENT]

4 The confirmation screen will appear to confirm your password. Type the password in once again and press [ENT].

[ENT]

EXIT CHANGE ON OFF

5 The password option screen will appear once again for 2 seconds and will automatically change to the main menu icons. Notice the [ON] indicator is now shown on the display.

Turning OFF the Password After a password is established, you can disable the password option. Once you disable the option, the password-input screen will not appear every time you power on the instrument.

Turning OFF the Password Option

1 From the main menu icons, press [F6](Para) to access the parameters option menu. Press [F3](Password) to access the password option.

Parameters F1 Measurement F2 Communication F3 Password

Password Input a password [ ]

EXIT BS

2 Type in your password and press [ENT]. 3 The password option screen will appear. The indicator on the upper left side of the screen will show [ON].

[ENT]

EXIT CHANGE ON OFF

Show 5 more labels / short text on this page
Type password · Type password · Password [ON] · Type password · Password [ON]
Page 99 of the Topcon GTS-822A user manual — [ENT]
Page 99 · click to enlarge
Page 99

8 PARAMETERS SETTING MODE

4 To turn off the password option, press [F6](OFF). The [ON] indication changes to [OFF] and the screen automatically changes back to the main menu icons.

EXIT CHANGE ON OFF

Changing a Password Once a password is established, you can change the original password. The new password takes the place of the original password in memory.

Changing the Password

1 From the main menu icons, press [F6](Para) to access the parameters option menu. Press [F3](Password) to access the password option.

Parameters F1 Measurement F2 Communication F3 Password

Password Input a password [ ]

EXIT BS

2 Type in your password at the blinking cursor and press [ENT].

[ENT]

3 The password option screen will appear. Press the [F2](Change) to change the current password.

EXIT CHANGE ON OFF

Password Input a password [ ]

EXIT BS

4 The password-input screen will appear. At the blinking cursor type in the new password and press the [ENT] key.

Password Input again (confirmation) [ ]

[ENT]

EXIT BS

5 The confirmation screen will appear to confirm your new password. Type in the new password once again and press [ENT].

[ENT]

EXIT CHANGE ON OFF

6 The password option screen will appear once again. Press the [F1](EXIT) to return back to the main menu icons.

Show 6 more labels / short text on this page
Password [OFF] · Type password · Password [ON] · Type password · Type password · Password [ON]
Page 100 of the Topcon GTS-822A user manual — B
Page 100 · click to enlarge
Page 100

9 CHECK AND ADJUSTMENT 9 CHECK AND ADJUSTMENT

9.1 Checking and Adjusting of Instrument Constant

Normally, the instrument constant does not have discrepancy. It is recommended you measure and compare with an accurately measured distance at a location where the precision is specifically monitored on a consistent basis. If such a location is not available, establish your own base line over 20m (when purchasing the instrument) and compare with the data measured with newly purchased instrument. In both cases note that the setup displacement of the instrument position over the point, the prism, baseline precision, poor collimation, atmospheric correction, and correction for refraction and earth curvature determine the inspection precision. Please keep in mind these points. Also, when providing a base line in a building, please note that the difference in temperature greatly changes the length measured in the building. If a difference of 5mm or over is the result from the comparative measurement, the following procedure as shown below could be used to change the instrument constant.

1. Provide point C on a straight line, connecting straight line AB which is almost horizontal and about 100m long, and measure straight lines AB, AC and BC.

B

A

2) Obtain the instrument constant by repeating 1) above several times. Instrument constant=AC+BC-AB 3) When there is error between written instrument constant value and calculated value, review the Section 9.7 “How to Set the Instrument Constant Value” procedure. 4) Once again, measure at a calibrated baseline and compare with the instrument base line the length. 5) If using above procedure and no difference is found from the instrument constant at the factory or a difference of over 5mm is found, contact TOPCON or your TOPCON dealer.

Page 101 of the Topcon GTS-822A user manual — 9 CHECK AND ADJUSTMENT
Page 101 · click to enlarge
Page 101

9 CHECK AND ADJUSTMENT

9.2 Checking the Optical Axis

To check if the optical axis of EDM and theodolite are matched, follow the procedure below. It is especially important to check after adjustment of the eyepiece reticle is carried out. 1) Position a prism about 30 to 50m apart from GTS-820A series. 2) After the power switch ON of GTS-820A series, collimate the center of the prism. 3) Press the soft key (Set audio) in the star key mode. Buzzer sounds continuously.

H direction confirmation (Do not move V direction). 4) Turn the horizontal jog counterclockwise slowly, move the collimating point to the left side of prism gradually until buzzer sound stops.

Topcon GTS-822A — 9 CHECK AND ADJUSTMENT diagram (page 101)
Fig. 35
5. Turn the horizontal jog clockwise slowly, and move the collimating point to the prism center gradually until at the position buzzer starts. Confirm the level of the signal (light quantity level) in display to adjust at the level of one to two as shown in below by turning the horizontal jog.
Topcon GTS-822A — 9 CHECK AND ADJUSTMENT diagram (page 101)
Fig. 36
6. Press the [ESC] key and measure the horizontal angle, and note the horizontal angle displayed. Or you can do 0-set of horizontal angle. 7) Return to the Set Audio in star key again. 8) Turn the horizontal jog clockwise, move the collimating point to the right side of prism gradually until buzzer sound stops.
Topcon GTS-822A — 9 CHECK AND ADJUSTMENT diagram (page 101)
Fig. 37
9. Move the collimating point to the center of prism gradually until buzzer sound starts. Turning the horizontal jog to be one to two level of SIG value to adjust the collimating point same as 5) procedure. 10) Note horizontal angle same as 6) procedure. 11) Calculate the average value of 6) and 10). [Example]
  • 6)
  • 0° 00’ 00” 10)
  • 0° 08’ 20” ___________________________

Average value 0° 04’ 10”

12. Climate to the center of prism. Compare the reading horizontal angle value and calculated value in 11). If the difference is within 1’30”, no problem for use.
Page 102 of the Topcon GTS-822A user manual — 9 CHECK AND ADJUSTMENT
Page 102 · click to enlarge
Page 102

9 CHECK AND ADJUSTMENT

Vertical direction confirmation (Do not move Horizontal direction).

13. Carry out as Horizontal direction confirmation. Compare the reading Vertical angle value and calculated value. If the difference is within 1’ 30”, no problem for use. If the difference is more than mentioned value, contact with your Topcon dealer or Topcon.

[Example] 90°12’ 30” 90° 04’ 30”

Reading to prism center 90°08’ 50” Difference 20”

Average 90°08’ 30”

Page 103 of the Topcon GTS-822A user manual — 9 CHECK AND ADJUSTMENT
Page 103 · click to enlarge
Page 103

9 CHECK AND ADJUSTMENT

9.3 Checking/Adjusting the Theodolite Functions

l Pointers on the Adjustment 1) Adjust the eyepiece of the telescope properly prior to any checking operation which involves sighting through the telescope. Remember to focus properly, with parallax completely eliminated. 2) Carry out the adjustments in the order of item numbers, as the adjustments are dependent one upon another. Adjustments carried out in the wrong sequence may even nullify previous adjustment. 3) Always conclude adjustments by tightening the adjustment screws securely (but do not tighten them more than necessary, as you may strip the threads, twist off the screw or place undue stress on the parts). Furthermore, always tighten by revolving in the direction of tightening tension. 4) The attachment screws must also be tightened sufficiently, upon completion of adjustments. 5) Always repeat checking operations after adjustments are made, in order to confirm results.

l Notes on the Tribrach Note that the angle measuring precision may be effected directly if the tribrach has not been installed firmly.

1. If there is any slack between the leveling screws and the base, loosen the set screw of the holding ring and tighten the holding ring with adjusting pin, until it is properly adjusted. Re-tighten the set screw on completing the adjustment.

Leveling screw Holding ring Set screw

Page 104 of the Topcon GTS-822A user manual — 9 CHECK AND ADJUSTMENT
Page 104 · click to enlarge
Page 104

9 CHECK AND ADJUSTMENT

9.3.1 Checking /Adjusting the Plate Level Adjustment is required if the axis of the plate level is not perpendicular to the vertical axis. l Check 1) Place the plate level parallel to a line running through the centers of two leveling screws, say, A and B. Use these two leveling screws only and place the bubble in the center of the plate level. 2) Rotate the instrument 180° or 200g around the vertical axis and check bubble movement of the plate level. If the bubble has been displaced, then proceed with the following adjustment.

l Adjustment 1) Adjust the level adjustment capstan screw, with the accessory adjusting pin and return the bubble towards the center of the plate level. Correct only one-half of the displacement by this method. 2) Correct the remaining amount of the bubble displacement with the leveling screws. 3) Rotate the instrument 180° or 200g around the vertical axis once more and check bubble movement. If the bubble is still displaced, then repeat the adjustment.

Level adjustment capstan screw

Half amount of displacement

9.3.2 Checking /Adjusting the Circular Level Adjustment is required if the axis of the circular level is also not perpendicular to the vertical axis. l Check 1) Carefully level the instrument with the plate level only. If the bubble of the circular level is centered properly, adjustment is not required. Otherwise, proceed with the following adjustment. l Adjustment 1) Shift the bubble to the center of the circular level, by adjusting three capstan adjustment screws on the bottom surface of the circular level, with the accessory adjusting pin.

Bottom of the base

Show 4 more labels / short text on this page
Plate level · Leveling screw B · Leveling screw A · Capstan adjustment screws
Page 105 of the Topcon GTS-822A user manual — 9 CHECK AND ADJUSTMENT
Page 105 · click to enlarge
Page 105

9 CHECK AND ADJUSTMENT

9.3.3 Adjustment of the Vertical Cross-hair Adjustment is required if the vertical cross-hair is not in a place perpendicular to the horizontal axis of the telescope (since it must be possible to use any point on the hair for measuring horizontal angles or vertically running lines). l Check 1) Set the instrument on the tripod and carefully level it. 2) Sight the cross-hairs on a well defined Point A at a distance of, at least, 50 meters (160ft.). 3) Next swing the telescope vertically using the jog/shuttle, and check whether the point travels along the length of the vertical cross-hair. 4) If the point appears to move continuously on the hair, the vertical cross-hair lies in a plane perpendicular to the horizontal axis (and adjustment is not required). 5) However, if the point appears to be displaced from the vertical cross-hair, as the telescope is swung vertically, adjustment is required in the reticle plate.

l Adjustment 1) Unscrew the cross-hair adjustment section cover, by revolving it in the counterclockwise direction, and take it off. This will expose four eyepiece section attachment screws.

Eyepiece section attachment screws

Eyepiece section attachment screws

2. Loosen all four attachment screws slightly with the accessory screw-drive (while taking note of the number of revolutions). Then revolve the eyepiece section so that the vertical cross-hair coincides to Point A’. Finally, re-tighten the four screws by the amount that they were loosened. 3) Check once more and if the point travels the entire length of the vertical cross-hair, further adjustment is not required.

Eyepiece

Page 106 of the Topcon GTS-822A user manual — 9 CHECK AND ADJUSTMENT
Page 106 · click to enlarge
Page 106

9 CHECK AND ADJUSTMENT

9.3.4 Collimation of the Instrument Collimation is required to make the line of sight of the telescope perpendicular to the horizontal axis of the instrument, otherwise, it will not be possible to extend a straight line by direct means. l Check 1) Set the instrument up with clear sights of about 50 to 60meters (160 to 200 ft.) on both sides of the instrument. 2) Level the instrument properly with the plate level. 3) Sight Point A at approximately 50 meters (160 ft.) distance.

4. Rotate the telescope 180° or 200g around the horizontal axis, so that the telescope is pointed in the opposite direction.
5. Sight Point B, at equal distance as Point A.
6. Rotate the instrument 180° or 200g around the vertical axis. Fix a sight on Point A once more.
7. Rotate the telescope 180° or 200g around the horizontal axis once more and fix a sight on Point C, which should coincide with previous Point B. 8) If Points B and C do not coincide, adjust in the following manner.

l Adjustment 1) Unscrew the cross-hair adjustment section cover. 2) Find Point D at a point between Points C and B, which should be equal to 1/4th the distance between Points B and C and measured from Point C. This is because the apparent error between Points B and C is four times the actual error since the telescope has been reversed twice during the checking operation.

3. Shift the vertical cross-hair line and coincide it with Point D, by revolving the left and right capstan adjustment screws with the adjusting pin.Upon completing the adjustment, repeat the checking operation once more. If Points B and C coincide, further adjustment is not required. Otherwise, repeat the adjustment.
Show 5 more labels / short text on this page
Eyepiece · Telescope · Capstan adjustment screws · Capstan adjustment screws · Eyepiece
Page 107 of the Topcon GTS-822A user manual — 9 CHECK AND ADJUSTMENT
Page 107 · click to enlarge
Page 107

9 CHECK AND ADJUSTMENT

Note: 1 First, loosen the capstan adjustment screw on the side to which the vertical cross-hair line must be moved. Then tighten the adjustment screw on the opposite side by an equal amount which will leave the tension of the adjustment screws unchanged. Revolve in the counterclockwise direction to loosen and in the clockwise direction to tighten, but revolve as little as possible. 2 Perform following adjustment after complete above adjustment. Section 9.4 “Adjustment of Compensation Systematic Error of Instrument” , Section 9.2 “Checking the Optical Axis” and Section 9.9 “Inspection and Adjustment of Optic Axis for Auto -Tracking” .

9.3.5 Checking / Adjusting the Optical Plummet Telescope Adjustment is required to make the line of sight of the optical plummet telescope coincide with the vertical axis (otherwise the vertical axis will not be in the true vertical above the reference point when the instrument is optically plumbed). l Check 1) Coincide the center mark and the point. (See Chapter 2 “PREPARATION FOR MEASUREMENT”.) 2) Rotate the instrument 180° or 200g around the vertical axis and check the center mark. If the point is properly centered in the center mark, adjustment is not required. Otherwise, adjust in the following manner.

l Adjustment 1) Take off the adjustment section cover of the optical plummet telescope eyepiece. This will expose four capstan adjustment screws which should be adjusted with the accessory adjusting pin to shift the center mark to the point. However, correct only one-half of the displacement in this manner.

Eyepiece Capstan adjustment screws

2. Use the leveling screws and coincide the point and center mark. 3) Rotate the instrument 180° or 200g around the vertical axis once more and check the center mark. If it is coincided to the point, then further adjustment is not required. Otherwise, repeat the adjustment.

Note: First, loosen the capstan adjustment screw on the side to which the center mark must be moved. Then tighten the adjustment screw on the opposite side by an equal amount which will leave the tension of the adjustment screws unchanged. Revolve in the counterclockwise direction to loosen and in the clockwise direction to tighten, but revolve as little as possible.

Capstan adjustment screws · 1/2 of displacement · Plummet telescope

Page 108 of the Topcon GTS-822A user manual — FACE 2
Page 108 · click to enlarge
Page 108

9 CHECK AND ADJUSTMENT

9.4 Adjustment of Compensation Systematic Error of Instrument

1. Error of vertical axis (X,Y tilt sensor offset) 2) Collimation error 3) Error of vertical angle 0 datum 4) Error of horizontal axis The above mentioned errors will be compensated by software, which calculated internally according to each compensation value. Also these errors can be compensated by software collimating one side of the telescope that is carried out to delete the error by turning in normal and reverse both sides of telescope so far.

1 Level the instrument properly with the plate level.

2 Press [F5] key from the main menu. [F5]

Adjustment F1 V0/Axis (Measurement) F2 V0/Axis (Constant list) F3 Date Time F4 Instrument constant ↓

3 Press [F1] key . [F1]

ERROR CORRECTION (A) Tilt,V0 init,Collimation (B) H Axis

(A)COLLIMATION

4 Collimate target A (around 0° in horizontal within ±3°) in normal telescope setting (FACE(1)).

FACE 1

LEVEL±0 /0

V: 88°40'20" SKIP SET

5 Press [F6](SET)key. *1) The sample display shows that the measurement is made 5 times in FACE 1.

FACE 1

LEVEL±0 /5

V: 89°55'50" SKIP SET

6 Turn the telescope in reverse telescope setting (FACE(2)).

FACE 2

LEVEL±0 0/5

V:270°04'20" SKIP SET

Show 4 more labels / short text on this page
[V0/Axis Adjustments] · Collimate · A (Normal) · Turn telescope
Page 109 of the Topcon GTS-822A user manual — FACE 1
Page 109 · click to enlarge
Page 109

9 CHECK AND ADJUSTMENT

7 Collimate target A. Collimate

8 Press [F6](SET)key. Repeat the procedures in step 7 and 8 so that the count of measured times matches to the one in FACE(1). * 2),3),4)

FACE 2

LEVEL±0 5/5

V:270°04'20" SKIP SET

The title display will be shown automatically.

FACE 2

LEVEL±10° /0

V:270°04'20" SKIP SET

9 Collimate target B (more than ±10° from the level ) in reverse telescope setting (FACE(2)). *5)

10 Press [F6](SET)key. *1) [F6]

FACE 2

LEVEL±10° /5

V:270°04'20" SKIP SET

11 Turn the telescope in normal telescope setting(FACE(1)).

FACE 1

LEVEL±10° 5/5

V: 69°58'30" SKIP SET

12 Collimate target B. Collimate

13 Press [F6](SET) key. Repeat the procedures in step 12 and 13 so that the count of measured times matches to the one in FACE(2). Then the display returns to main menu.

*1) It is able to get the average value from 1 to 10 measurements. To get the average, repeat the procedures in steps 4, 5 or 9, 10. The measured times is counted in the second line of display. *2) The compensation values of 1) Error of vertical axis (X,Y tilt sensor offset), 2) Collimation error, and 3) Error of vertical angle 0 datum will be set and memorized internally. *3) The operating procedure steps to set compensation value of 4) Error of horizontal axis. *4) Pressing [F1](SKIP) key enables to set next step without changing the last compensated value. *5) Pressing [F1](SKIP) key makes end of setting without changing compensation value.

Show 7 more labels / short text on this page
A (Reverse) · (B)HORIZONTAL Axis · Collimate · B (Reverse) · Turn telescope · B (Normal) · Complete
Page 110 of the Topcon GTS-822A user manual — EXIT ON OFF
Page 110 · click to enlarge
Page 110

9 CHECK AND ADJUSTMENT

9.5 Showing Constant List and Switch ON/OFF Compensation Systematic Error of Instrument

[Example settingSwitch OFF the compensation]

1 Press [F5] key from the main menu. [F5]

Adjustment F1 V0/Axis (Measurement) F2 V0/Axis (Constant list) F3 Date Time F4 Instrument constant ↓

2 Press [F2] key . Correction values are displayed.

Vco-1°57'12" Hco: -0°00'20" HAx: -0°00'20"

EXIT ON OFF

3 Press [F6](OFF) key. [F6]

Vco-1°57'12" Hco: HAx:

EXIT ON OFF

4 Press [F1](EXIT) key. The display returns to main menu.

Page 111 of the Topcon GTS-822A user manual — [1][3] [2][0] [5][0] [ENT]
Page 111 · click to enlarge
Page 111

9 CHECK AND ADJUSTMENT

9.6 How to adjust the date and time

1 Press [F5] key from the main menu. [F5]

Adjustment F1 V0/Axis (Measurement) F2 V0/Axis (Constant list) F3 Date Time F4 Instrument constant ↓

2 Press [F3] key. Current date will be on the display.

Current date is 01-25-02 Enter new date (mm-dd-yy) Modify YES NO

3 Press [F5] (YES) key. The cursor will blink on the first digit to type in a numeric value.

Current date is 01-25-02 Enter new date (mm-dd-yy) EXIT BS

4 Input new date and press [ENT] key. [Example:07-29-02]

[0][7] [2][9] [0][2] [ENT]

Current time is 14:55:28 Enter new time (hh-mm-ss) Modify YES NO

5 Press [F5] (YES) key. [F5]

Current time is 14:55:28 Enter new time (hh-mm-ss)

EXIT BS

6 Input new time and press [ENT] key. [Example:13:20:50] The display returns to main menu.

[1][3] [2][0] [5][0] [ENT]

l The [F6](BS) key is for moving the cursor to the left one digit at a time for editing.(If you do not want to change the date, press the [F1](EXIT) key or [ESC] key to get to the time display. l Enables you to change the order of date, see Chapter 8 “PARAMETERS SETTING MODE” .

Page 112 of the Topcon GTS-822A user manual — 9 CHECK AND ADJUSTMENT
Page 112 · click to enlarge
Page 112

9 CHECK AND ADJUSTMENT

9.7 How to Set the Instrument Constant Value

To set the Instrument constant which is obtained in section 9.1 “Checking and Adjusting of Instrument Constant”, follow as below.

1 Press the [F5] key from the main menu. [F5]

Adjustment F1 V0/Axis (Measurement) F2 V0/Axis (Constant list) F3 Date Time F4 Instrument constant ↓

2 Press [F4] (Instrument constant) key. [F4]

Instrument Constant EDM OFSET (mm) 0.0 Modify YES NO

3 Press [F5] (YES) key . [F5]

Instrument Constant EDM OFFSET (mm) 0.0 EXIT BS

4 Input value and press [ENT] key. Input value [ENT]

Instrument Constant EDM OFFSET (mm) 1.2 OK CANCEL

5 Press [F5](OK) key.

The display returns to main menu.

Complete

Page 113 of the Topcon GTS-822A user manual — EXIT
Page 113 · click to enlarge
Page 113

9 CHECK AND ADJUSTMENT

9.8 Reference Frequency Checking Mode

The beam modulated by the reference frequency of EDM is emitted continuously. This mode is used for frequency test mainly.

1 Press the [F5] key from the main menu icons. [F5]

Adjustment F1 V0/Axis (Measurement) F2 V0/Axis (Constant list) F3 Date Time F4 Instrument constant ↓

2 Press the [F6](↓) key to get to next page on the display.

Adjustment F1 FRQ check F2 Adj Tracking Axis

3 Press the [F1] key. The beam will be emitted.

  • FRQ Check During the signal output

EXIT

4 To return to the main menu icons, press the [F1] (EXIT) key.

↑

Page 114 of the Topcon GTS-822A user manual — 9 CHECK AND ADJUSTMENT
Page 114 · click to enlarge
Page 114

9 CHECK AND ADJUSTMENT

9.9 Inspection and Adjustment of Optic Axis for Auto -Tracking

Activates auto tracking to the prism. Confirm if the center of telescope reticle and the center of the prism is coincided. Any error between them requires adjustment according to the following procedure.

Centers of prism and telescope is shifted Normal position

l Position a prism around 0 in horizontal and more than100m (328ft) apart from the GTS-820A series. l Take care not to be interrupted the optical path during measurement.

1 Level the instrument properly with the plate level and press the [F5] key from main menu.

Adjustment F1 V0/Axis (Measurement) F2 V0/Axis (Constant list) F3 Date Time F4 Instrument constant ↓

2 Press the [F6] key to get the next page. [F6]

Adjustment F1 FRQ check F2 Adj Tracking Axis

3 Press the [F2] key to select the adjustment of tracking axis.

Adj Tracking Axis [1/2] >Sight the prism !! TURN MEAS

4 Operate H / V jog shuttle to collimate the center of prism

5 Press the [F6](MEAS) key. The measurement starts.

6 After the measurement, press the [F1](TURN) key. The instrument and telescope will turn automatically.

Adj Tracking Axis [2/2] >Sight the prism !! TURN MEAS

7 Operate H / V jog shuttle to collimate the center of prism

Show 9 more labels / short text on this page
Prism center · Prism center · Telescope reticle center · Telescope reticle center · ↑ · Collimate · Adj Tracking Axis · Wait · Collimate
Page 115 of the Topcon GTS-822A user manual — YES NO
Page 115 · click to enlarge
Page 115

9 CHECK AND ADJUSTMENT

8 Press the [F6](MEAS) key. The measurement starts.

The shifted quantity between H angle and V angle measured from the measuring will be calculated internally.

Adj Tracking Axis >Set OK?

YES NO

9 Confirm the coincident of cross hair line and the senter of prism, press the [F5](YES) key. The compensation value will be set and memorized to GTS-820A series. The display will return to the main menu.

l The display shows “Compensation Range Overcoat” when the calculated compensation value is exceeded than limited value. l If the distance between the instrument and the prism is not enough to adjust, the display shows “The distance is too short”. The distance between the instrument and prism should be more than 35m. l If the difference of the measured data between in normal position and in inverted position is exceeded than limited value, the display shows “Tolerance Limit Over”. l If the measuring is unstable when the atmospheric condition is bad or the optical path is interrupted, the display shows “Standard Deviation Over”. l To cancel the compensation, press the [F6](NO) key.

Adj Tracking Axis · Wait · Complete

Page 116 of the Topcon GTS-822A user manual — [ENT]
Page 116 · click to enlarge
Page 116

10 SETTING THE PRISM CONSTANT VALUE 10 SETTING THE PRISM CONSTANT VALUE

The prism constant value of Topcon is set to zero. When using prism other than Topcon's, it is necessary to set the prism constant correction value of that specific prism. Once you set the correction value for prism constant, it is retained after power is OFF. l Setting the prism constant value is in the STAR key mode.

l Setting exampleThe prism constant value : -14mm

1 Press STAR (H) key. Press the [F6] key twice to get the page three.

[H] [F6] twice

2003-10-10 14:30:40

2 Press the [F2] key. Current setting value is displayed.

20.0 °C -5.1ppm

-2.0 mm 1012.0hPa

3 Move the cursor (>) to psm setting by pressing [F5]((→, ←) key or [F6](↓,↑) key.

4 Input the Prism constant correction value and press the [ENT] key. *1)

20.0 °C 5.1ppm

+14.0 mm 1012.0hPa

[ENT]

The display returns STAR key menu.

*1) Input range-99.9mm to +99.9mm, 0.1mm step
Show 4 more labels / short text on this page
3↓ · prism setting · Move cursor · Enter value
Page 117 of the Topcon GTS-822A user manual — [ENT]
Page 117 · click to enlarge
Page 117

11 SETTING ATMOSPHERIC CORRECTION 11 SETTING ATMOSPHERIC CORRECTION

The velocity of light through air is not constant and depends on the atmospheric temperature and pressure. The atmospheric correction system of this instrument corrects automatically when the correction value is set. 15°C/59°F, and 1013.25hPa / 760mmHg / 29.9 inHg is as a standard value for 0ppm in this instrument. The values are kept in the memory even after power is OFF. l Setting the atmospheric correction value is in the STAR key ( H) mode.

11.1 Calculation of Atmospheric Correction

The followings are the correction formulas. Unit; meter

Ka: Atmospheric correction value P : Ambient atmospheric pressure (hPa) t : Ambient Atmospheric temperature (°C) Ka 279.67 79.535 P × 273.15 t + – 10 6 – × =

The distance L (m) after atmospheric correction is obtained as follow. L = l (1+Ka) l :Measured distance when atmospheric

correction is not set.

ExampleIn case Temperature +20°C, Air pressure 847hPa, l =1000 m

Ka 279.67 79.535 847 × 273.15 20 + – 10 6 – × =

+ 50×10-6 (50 ppm)

L = 1000 (1+50×10-6) = 1000.050 m

11.2 Setting of Atmospheric Correction Value

l How to Set Temperature and Pressure Value Directly Measure the temperature and air pressure surrounding the instrument beforehand. Example : Temperature: +26°C, Pressure:1020 hPa

1 Press STAR (H) key. Press the [F6] key twice to get the page three.

[H] [F6] twice

2003-10-10 14:30:40

2 Press the [F2] key. Current setting value is displayed.

20.0 °C 5.1ppm

-2.0 mm 1012.0hPa

3 Input Temp.value and press [ENT] key. [Example] Temp. : +26°C The cursor moves to Pressure setting automatically

26.0 °C 5.1ppm

-2.0 mm 1012.0hPa

[ENT]

4 Input Pressure value, and press [ENT]. [Example] Pres. :1020.0hPa. The display returns previous mode. *1) *2)

26.0 °C 5.1ppm

-2.0 mm 1020.0hPa

[ENT]

Show 5 more labels / short text on this page
3↓ · Temperature setting · Enter value · Pressure setting · Enter value
Page 118 of the Topcon GTS-822A user manual — [ENT]
Page 118 · click to enlarge
Page 118

11 SETTING ATMOSPHERIC CORRECTION

The display returns STAR key menu.

*1) Range : Temp. -30.0 °C to +60.0 °C (0.1 °C step) Pres. 560.0 to1066.0hPa (0.1hPa step) , 420.0 to 800.0mmHg (0.1mmHg step) 16.5 to 31.5inHg (0.1inHg step) *2) When the atmospheric correction value, which is calculated from the input temperature and pressure values, exceeds the range ± 999.9ppm, the operating procedure returns to step 3 automatically. Input values again.

l How to Set the Atmospheric Correction Value Directly Measure the temperature and air pressure to find atmospheric correction value (ppm) from the chart or correction formula. [Example] Atmospheric correction value

1 Press STAR (H) key. Press the [F6] key twice to get the page three.

[H] [F6] twice

2003-10-10 14:30:40

2 Press the [F2] key. Current setting value is displayed.

20.0 °C 5.1ppm

-2.0 mm 1012.0hPa

3 Move the cursor (>) to ppm setting by pressing [F5](→) key.

5.1ppm

-2.0 mm

4 Enter atmospheric correction value and press [ENT] key. *1)

[ENT]

The display returns previous mode.

*1) Input range-999.9mm ~ +999.9mm, 0.1mm step

3↓ · Move cursor · Enter ppm

Page 119 of the Topcon GTS-822A user manual — 11 SETTING ATMOSPHERIC CORRECTION
Page 119 · click to enlarge
Page 119

11 SETTING ATMOSPHERIC CORRECTION

Atmospheric Correction Chart (For your reference)

The atmospheric correction value is obtained easily with the atmospheric correction chart. Find the measured temperature in horizontal, and pressure in vertical on the chart. Read the value from the diagonal line, which represents the required atmospheric correction value.

Example: The measured temperature is +26°C The measured pressure is 1013 hPa Therefore, The correction value is +10ppm

Topcon GTS-822A — 11 SETTING ATMOSPHERIC CORRECTION diagram (page 119)
Fig. 38
Page 120 of the Topcon GTS-822A user manual — 11 SETTING ATMOSPHERIC CORRECTION
Page 120 · click to enlarge
Page 120

11 SETTING ATMOSPHERIC CORRECTION

Topcon GTS-822A — 11 SETTING ATMOSPHERIC CORRECTION diagram (page 120)
Fig. 39
Topcon GTS-822A — 11 SETTING ATMOSPHERIC CORRECTION diagram (page 120)
Fig. 40
Page 121 of the Topcon GTS-822A user manual — 11 SETTING ATMOSPHERIC CORRECTION
Page 121 · click to enlarge
Page 121

11 SETTING ATMOSPHERIC CORRECTION

Topcon GTS-822A — 11 SETTING ATMOSPHERIC CORRECTION diagram (page 121)
Fig. 41
Page 122 of the Topcon GTS-822A user manual — 12.1 Distance Calculation Formula
Page 122 · click to enlarge
Page 122

12 CORRECTION FOR REFRACTION AND EARTH CURVATURE 12 CORRECTION FOR REFRACTION AND EARTH CURVATURE

The instrument measures distance, taking into account correction for refraction and earth curvature.

12.1 Distance Calculation Formula

Distance Calculation Formula; with correction for refraction and earth curvature taken into account. Follow the Formula below for converting horizontal and vertical distances.

Horizontal distance D = AC(α) or BE(β) Vertical distance Z =BC(α) or EA(β) D = L{cosα–(2θ – γ ) sinα} Z = L{sinα+(θ – γ ) cosα}

θ = L.cosα/2R Earth curvature

γ =K•Lcosα/2R Atmospheric refraction correcting item

K =0.14 or 0.2 Coefficient of

R =6372km Radius of earth α ( or β) Altitude angle L Slope distance

  • l The conversion formula for horizontal and vertical distances is as follows when correction for refraction and earth curvature is not applied. D=L
  • cos α Z=L
  • sin α

correcting item · refraction

Page 123 of the Topcon GTS-822A user manual — 13.1 Rechargeable Battery BT-56Q
Page 123 · click to enlarge
Page 123

13 POWER SOURCE AND CHARGING 13 POWER SOURCE AND CHARGING

13.1 Rechargeable Battery BT-56Q

l To remove Remove the battery while pulling both battery fixing levers.

Topcon GTS-822A — 13.1 Rechargeable Battery BT-56Q diagram (page 123)
Fig. 42 · 13.1 Rechargeable Battery BT-56Q

l To charge 1 Plug the charger into the outlet. 2 Connect the charger connector to the battery, then charging will start. Preparatory charging will start.* (The red lamp of the charger will blink.) When the preparatory charging is completed, the charging status will be switched to quick charging automatically. (The red lamp of the charger will light.) 3 Charging will take approximately 2.5 hours. (The green lamp will illuminate.) 4 After charging, remove the battery from the charger. Remove the charger from the outlet. l To refresh Press the refresh switch after starting charging above steps (1, 2 ), then discharging will start. Confirm the yellow lamp illuminates. After discharging is finished , charging will start automatically. Time discharging battery charged fully is approximately 12 hours. l For refreshing Rechargeable battery can be used repeatedly by charging. If charging is repeated by the state that capacity of the battery still left, operating time of the battery may shorten. In this case, the voltage of the battery will be recovered by refreshing and operating time can be improved. *About Preparatory charging Before quick charging, the battery is charged using small amount current to measure its temperature and voltage. When the temperature and voltage is within a range, the charging status will change to quick charging. The lamp of charger

Red blinking : Preparatory charging Red ON: Charging Red lamp will illuminate during charging. Green ON: Charging completed Green lamp will illuminate after completely charging. Yellow ON: Discharging Yellow lamp will illuminate and discharging will start by pressing the refresh (discharge) switch. Red quick flashing: Abnormal outbreaks

Red lamp will flash when the battery life is over or the battery is broken down. Replace the battery to new one. l To install 1 Place the battery to the instrument. 2 Gentry push the battery and clicks into position.

AC-outlet

Page 124 of the Topcon GTS-822A user manual — 13 POWER SOURCE AND CHARGING
Page 124 · click to enlarge
Page 124

13 POWER SOURCE AND CHARGING

l Do not charge or discharge continuously, otherwise the battery and the charger may be deteriorated. If charging or discharging is necessary, use the charger after stopping charge for approximately 30 minutes. l Do not charge the battery or discharge the battery in right after the battery is charged, it causes deterioration of the battery in rare cases. l The charger may develop heat while charging, there is no problem of it.

Note: 1 Recharging should take place in a room with an ambient temperature range of 10°C to 40°C (50°F to 104°F). 2 If charging is done at high temperature, charging time of the battery may take longer. 3 Exceeding the specified charging time may shorten the life of the battery and should be avoided if possible. 4 The battery source will discharge when stored and should be checked before using with instrument . 5 Be sure to charge as stored battery source every 3 or 4 months and store in a place at 30°C and below when it will not used for a long period. If you allow the battery to be completely discharged, it will have an effect on the overall performance for proper charging in the future. Keep batteries charged at all times. 6 For further information, see APPENDIX 2 “Precaution when Charging or Storing Batteries”.

Page 125 of the Topcon GTS-822A user manual — 14 DETACH/ATTACH OF TRIBRACH 14 DETACH/ATTACH OF TRIBRACH
Page 125 · click to enlarge
Page 125

14 DETACH/ATTACH OF TRIBRACH 14 DETACH/ATTACH OF TRIBRACH

The instrument is easily detached or attached to the tribrach.

Topcon GTS-822A — 14 DETACH/ATTACH OF TRIBRACH 14 DETACH/ATTACH OF TRIBRACH diagram (page 125)
Fig. 43
Topcon GTS-822A — 14 DETACH/ATTACH OF TRIBRACH 14 DETACH/ATTACH OF TRIBRACH diagram (page 125)
Fig. 44

l Detachment 1) Loosen the tribrach fixing screw. 2) Loosen the tribrach fixing lever by turning counterclockwise. 3) Lift the instrument straight upwards and off.

l Attachment 1) Coincide the white alignment piece on the lower part of the instrument with the tribrach alignment groove. 2) Tighten the tribrach fixing lever firmly by turning clockwise. 3) Tighten the tribrach fixing screw.

l Locking the Tribrach Fixing lever The tribrach fixing lever can be locked from being moved accidentally. This is useful if the upper instrument section is not being detached very often. Simply tighten the securing screw on the fixing lever with the accessory screw driver.

Tribrach fixing screw

Page 126 of the Topcon GTS-822A user manual — BT-3L
Page 126 · click to enlarge
Page 126

15 BATTERY SYSTEM 15 BATTERY SYSTEM

In case of Rechargeable Battery BT-56Q In case of External battery Pack

Topcon GTS-822A — 15 BATTERY SYSTEM 15 BATTERY SYSTEM diagram (page 126)
Fig. 45

BT-56Q

BC-27BR/CR

Quick BC-27BR for AC 120V use BC-27CR for AC 230V use Approx. 2.5h

Topcon GTS-822A — BT-56Q diagram (page 126)
Fig. 46

Normal BC-10B for AC 120V use BC-10C for AC 230V use

Quick for AC 100V / 120V / 220V / 240V use

Quick for DC 13.8 to 16V use

Approx.15h

BC-6

Normal for AC 100V / 120V / 220V / 240V use

BT-3L

External 12V battery · Charging · Charging time

Page 127 of the Topcon GTS-822A user manual — 16 PRISM SYSTEM 16 PRISM SYSTEM
Page 127 · click to enlarge
Page 127

16 PRISM SYSTEM 16 PRISM SYSTEM

Arrangement according to your needs is possible.

Topcon GTS-822A — 16 PRISM SYSTEM 16 PRISM SYSTEM diagram (page 127)
Fig. 47

Target pole-2 (not used with 9 prisms)

Tilting prism holder-2 with target plate-2

Tilting triple prism holder-1

It is possible to change the combination according purpose.

Topcon GTS-822A — 16 PRISM SYSTEM 16 PRISM SYSTEM diagram (page 127)
Fig. 48

Fixed 9 prisms unit

Tilt single prism unit

Fixed 3 prisms unit

l Use the above prisms after setting them at the same height as the instruments. To adjust the height of prism set, change the position of fixing screws. Plug 3 is necessary for the tribrach adaptor-2, tribrach adaptor-S2 and pole adaptor-F2 to coincide with the height of GTS-820A series. l TR-5 or TR-5P tribrach should be used for prism side when the traverse surveys is performed.

Show 14 more labels / short text on this page
Prism-2 · 9 prism holder-2 · Tilting prism holder-3 · Single prism holder-2 · Triple prism holder-2 · Pole adaptor- A · Plug3 · Tribrach adaptor-2 · Tribrach adaptor-S2 · Pole adaptor- F2 · Tribrach · Optical plummet tribrach · Prism unit A3/A3S · Tripod
Page 128 of the Topcon GTS-822A user manual — 17 PRECAUTIONS 17 PRECAUTIONS
Page 128 · click to enlarge
Page 128

17 PRECAUTIONS 17 PRECAUTIONS

1. For transportation, hold by the handle or yoke of the instrument. Never hold by the lens barrel as it can affect the fixing bracket inside and reduce the accuracy of the instrument.
2. Never expose the instrument without a filter to direct sunlight. It may damage the components inside the instrument.
3. Never leave the instrument unprotected in high temperature. The temperature inside instrument may easily reach up to 70°C or above and will reduce the service life.
4. When a high degree of precision is required for measurement, provide shade against direct sunlight for the instrument and tripod.
5. Any sudden change of temperature to the instrument or prism may result in a reduction of measuring distance range, i.e. when taking the instrument out from a heated vehicle.
6. When opening the carrying case and taking out the instrument, place the case horizontally, then open the case.
7. When returning the instrument to its case, be sure to match the white positioning marks provided with the case and place the instrument with the eyepiece upward.
8. For transportation, provide dampening or a cushion appropriately to avoid sudden shock or vibration.
9. For cleaning the instrument after use, remove dust using a cleaning brush, then wipe off with a cloth.
10. For cleaning the lens surface, use a cleaning brush to remove the dust, then use a clean lintless cotton cloth. Moisten it with alcohol (or mixture with ether) to wipe gently in a rotational motion from the center out.
11. Even if any abnormality occurs, never attempt to disassemble or lubricate the instrument yourself. Always consult with TOPCON or your dealer.
12. To remove the dust on the case, never use thinner or benzine. Use a clean cloth moistened with neutral detergent.
13. Check each part of the tripod after extended use. Parts (screws or clamps) may work themselves free.
Page 129 of the Topcon GTS-822A user manual — E81 E82
Page 129 · click to enlarge
Page 129

18 ERROR DISPLAYS 18 ERROR DISPLAYS

Error code Description Countermeasures

Displayed when built in battery for memory back up is empty. Contact your dealer or Topcon.

Displayed when measurement carried out within ±9° from zenith or nadir at the Earth curvature and refraction correction mode is ON.

Set correction for refraction and earth curvature mode OFF or measure out of ±9° from the zenith or Nadir.

W/C OVER

Displayed when the instrument rotated too fast or any abnormality occurs in angle measuring system .

The instrument will return to previous mode automatically.

Displayed when the telescope rotated too fast or any abnormality occurs in angle measuring system.

The instrument will return to previous mode automatically.

Displayed when the unit of the angle at the recall mode is different from the unit stored in setting mode.

E31

Make the unit in same unit system.

E35 Displayed when REM measurement carried out to the range from zenith or nadir ± 6° .

Operate in the range out of ± 6° from the zenith or nadir.

Displayed when the N.E coordinates are set same as the instrument coordinate in setting direction angle or lay out mode.

E36

Set except the instrument coordinate value.

E60’s Any abnormality occurs with EDM (distance measuring system). Repair is required.

E71 Displayed when Vertical angle 0 position is set with incorrect procedure. Confirm the procedure and readjust.

E72 Displayed when Vertical angle -position is adjusted in wrong position. Confirm the procedure and readjust

E73 The instrument was not leveled when Vertical angle 0-position is adjusted.

Level the instrument then carry the adjustment work.

E81 E82

Mainly at the time data transmission between GTS-820 series and external instrument.

Press [F1](EXIT) key, and confirm the connection cables are correct.

Data transmission error between internal P.C.B.‘s.

Restart and confirm the operation procedure is correct.

E90‘s Abnormality in internal memory system. Repair is required.

E300‘s Abnormality in tracking system. Repair is required.

E600‘s Abnormality in angle measuring system. If this error code continues to display, repair is required.

E700‘s Abnormality in angle measuring system. If this error code continues to display, repair is required.

E800‘s In the self checking mode, vibration is too big. Get rid of the Vibration

l If error still persist after attempting to clear them, contact your local Topcon dealer or Topcon head office.

Show 8 more labels / short text on this page
Backup · battery · empty · H angle measuring · error · V angle measuring · error · Other E80‘s
Page 130 of the Topcon GTS-822A user manual — 19 SPECIAL ACCESSORIES 19 SPECIAL ACCESSORIES
Page 130 · click to enlarge
Page 130

19 SPECIAL ACCESSORIES 19 SPECIAL ACCESSORIES

Remote Control System RC-2II Using together with RC-2II makes it possible to optical communication between the GTS-820A series and RC-2II. This gives easy operation for one man surveying.

Optical plummet tribrach TR-5P This is detachable tribrach having built-in optical plummet telescope. (Compatible with Wild)

Trough compass, Model 6 Shock proof construction. No clamp is necessary when carrying the instrument.

Tribrach TR-5 This is detachable tribrach having tribrach fixing screw.

Diagonal eyepiece, Model 10 Observation in an easy posture will be provided up to the zenith position

Solar filter, Model 6 A filter designed exclusively for direct collimation of the sun. Solar filter of flap-up type.

Solar reticle, Model 6 A reticle designed for collimation of the sun. Can be used together with Solar Filter.

Page 131 of the Topcon GTS-822A user manual — 19 SPECIAL ACCESSORIES
Page 131 · click to enlarge
Page 131

19 SPECIAL ACCESSORIES

Topcon GTS-822A — 19 SPECIAL ACCESSORIES diagram (page 131)
Fig. 49

Prism unit case, Model 6 Fixed 9 prisms unit or tilting 3 prisms unit can be stored in this case. Especially, this is a very easy case to carry. Soft material is used. l External dimensions: 250(L)×120(W)×400(H) mm l Weight:0.5kg

Prism unit case, Model 3 This is the plastic case to store and carry various sets of prisms. The case covers one of the following prism sets: l Tilt single prism set l Tilt single prism set with a target plate l Fixed triple prism unit l Fixed triple prism unit with a target plate l External dimensions: 427(L)×254(W)×242(H) mm l Weight:3.1kg

Prism unit case, Model 5 1 prisms unit or fixed 3 prisms unit can be stored in this case. Especially, this is a very easy case to carry. Soft material is used. l External dimensions: 200(L)×200(W)×350(H) mm l Weight:0.5kg

Gadget case, Model 1 A case to store and carry accessories. l External dimensions: 300(L)×145(W)×220(H) mm l Weight:1.4kg

Back pack, Model 2 Convenient for use in mountainous terrain.

Cigarette battery charger BC-9 (for BT-3Q) l Input voltage:13.8V to 16V l Power consumption: 40VA approx. l Charging time: approx. 2 hour (+20°C) to charge BT-3Q l Operation temperature range: +10°C to +40°C (+50 to +104°F) l External dimensions: 116(L)×60(W)×50(H) mm l Weight:0.3kg

Battery charger BC-6 (for BT-3L) l Input voltage:100, 120, 220, 240V AC: ±10% 50/60 Hz l Power consumption: 15VA approx. l Charging time: approx. 15 hour (+20°C) to charge BT-3L l Operation temperature range: +10°C to +40°C (+50 to +104°F) l External dimensions: 142(L) × 96(W) × 64(H) mm l Weight:1.0kg

Page 132 of the Topcon GTS-822A user manual — 19 SPECIAL ACCESSORIES
Page 132 · click to enlarge
Page 132

19 SPECIAL ACCESSORIES

Power cord PC-6 (For BT-3L, AC-6) l L-shape plug provided l Cord length: 2m approx.

Power cord PC-5 (For BT-3Q, AC-6 and TOPCON FC series Data collector) l L-shape plug provided l Cord length: 2m approx.

Large capacity battery pack BT-3L l Output voltage : DC 8.4V l Capacity: 6AH l External dimensions: 190(L) × 106(W) × 74(H) mm l Weight:2.8kg

Auto Converter AC-6 l Input voltage : DC12V l Output voltage : DC 8.4V±5% l Current rating : 3A l Connection cable length : Approx. 3m l External dimensions : 100(L) x 50(W) x 52(H) mm l Weight : Approx. 300g

Aluminum extension leg tripod, Type E l Flat head 5/8" × 11 threads with adjustable legs.

Wide-frame extension leg tripod, Type E (Wood) l Flat head 5/8" × 11 threads with adjustable legs.

Prism sets See the description on Chapter 16 "PRISM SYSTEM"

Topcon GTS-822A — 19 SPECIAL ACCESSORIES diagram (page 132)
Fig. 50

Data card

Page 133 of the Topcon GTS-822A user manual — 20 SPECIFICATIONS 20 SPECIFICATIONS
Page 133 · click to enlarge
Page 133

20 SPECIFICATIONS 20 SPECIFICATIONS

Telescope Length : 166mm Objective lens : 50mm (EDM 50mm) Magnification : 30× Image : Erect Field of view : 1°30' Resolving power : 3" Minimum focus : 1.3m Focusing knob : 1 speed way

Automatic Tracking / Collimating Maximum Automatic Tracking speed : 12° /sec Automatic Collimating area : ±5° Automatic Tracking range *1:

Prism type 2, with 1 prism 8 to 800 m (26 to 2,625ft)

Prism Unit Type A2/A3/A3S 10 to 500 m (33 to 1,640ft)

Reflector tape (5cm× 5cm) 10 to 50 m (33 to 164 ft)

Automatic Collimation / Tracking accuracy : 3” Standard deviation *2 Search pattern : Pattern 1 / Pattern 2 Search range : Any value can be set, able to set (1° step) Safety standard for Laser Beam : Class 1 (IEC Publication 825)

Class ll (FDA/BRH 21 CFR 1040)

*1 Condition : Normal (Visibility about 20km), except high humidity time. Automatic Tracking range of Reflector tape will differ depending on the kind of reflector tape. *2 The air condition is stable and prism is staying. Automatic Collimation / Tracking accuracy is available only for prism use except for reflector tape.

Manual Driving Maximum rotating speed * : 50° /sec Coarse movement : Shuttle driving (in 7 steps) Fine movement : Jog driving (minimum step about 1 second)

*By reverse, rotating instruction

Page 134 of the Topcon GTS-822A user manual — 20 SPECIFICATIONS
Page 134 · click to enlarge
Page 134

20 SPECIFICATIONS

Distance measurement Measurement range

Condition 1 Condition 2

Mini prism 800m ( 2,600ft)

1 prism 2,200m (7,200ft) 2,500m (8,200ft)

3 prisms 2,800m (9,200ft) 3,200m (10,500ft)

9 prisms 3,600m (11,800ft) 4,200m (13,800ft)

Condition 1Sight haze with visibility about 20km (12.5miles) moderate sunlight with light heat
shimmer. Condition 2No haze with visibility about 40km(25 miles), overcast with no heat shimmer. Measurement accuracy

Fine measurement mode : ±(2mm + 2ppm × D) m.s.e. Coarse measurement mode : ±(10mm + 2ppm × D) m.s.e.

DMeasuring distance (mm) Least Count in Measurement

Fine measurement mode : 1mm (0.005ft.) / 0.2mm (0.001ft) Coarse (1mm) measurement mode : 1mm (0.005ft.) Coarse (10mm) measurement mode : 10mm (0.02ft.) Measurement Display : 10digit : max. display ±999999.9999m Measurement Time

Fine measurement mode : 1mm : 1.2 sec. (Initial 4 sec.) : 0.2mm: 2.8 sec. (Initial 5 sec.) Coarse (1mm) measurement mode : 0.7sec. (Initial 3sec.) Coarse (10mm) measurement mode : 0.4sec. (Initial 3sec.)

(The initial time will be different by a condition.)

Atmospheric Correction Range : –999.9ppm to +999.9ppm , in 0.1ppm increments Prism Constant Correction Range : –99.9 mm to +99.9 mm , in 0.1 mm increments Coefficient Factor : Meter / Feet

International feet 1meter = 3.2808398501 ft. US SURVEY feet 1meter = 3.2808333333 ft. Ambient Temperature Range : –20°C to +50°C (–4°F to +122°F)

Electronic Angle Measurement MethodAbsolute reading Detecting system : Horizontal : 2 sides
Vertical2 sides Minimum reading

GTS-821A : 1"/0.5" (0.5mgon/0.1mgon, 5mmil/2mmil) reading GTS-822A : 1"/0.5" (0.5mgon/0.1mgon, 5mmil/2mmil) reading GTS-823A : 5"/1" (1mgon/0.2mgon, 20mmil/5mmil) reading GTS-825A : 5"/1" (1mgon/0.2mgon, 20mmil/5mmil) reading

Accuracy(Standard deviation based on DIN 18723 )

GTS-821A : 1" (0.3mgon ) GTS-822A : 2" (0.6mgon ) GTS-823A : 3" (1mgon ) GTS-825A : 5" (1.5mgon )

Diameter of circle71mm

Atmospheric conditions · Prism

Page 135 of the Topcon GTS-822A user manual — 20 SPECIFICATIONS
Page 135 · click to enlarge
Page 135

20 SPECIFICATIONS

Tilt Correction Method : Automatic vertical and Horizontal index : Liquid type Compensating Range : ±4' Correction unit : 1"(0.1mgon)

Others Instrument height : 196mm (7.7 in) Base unit detachable (Height from the tribrach dish to the center of telescope) Level sensitivity

Circular level10'/2mm Plate level : 30"/2 mm

Magnification : 3 × Focusing range : 0.5m to infinity Image : Erect Field of view : 4°

Laser classClass 2 (Class ll) laser product
Dimension325 (H) × 229 (W) × 211 (L) mm

(12.8 (H) × 8.9 (W) × 8.3 (L) in) Weight

GTS-820series7.5kg ( 16.6 lbs) Plastic carrying case : 5.4kg ( 11.9 lbs) Durability
Protection against water and dustIP54 (with BT-56Q)

(Based on the standard IEC60529)

OSMS-DOS Ver.3.22 Internal Memory

System memory : FEEPROM 512KB Main memory : RAM 640 KB Data memory : FEEPROM 2 MB Program memory : FEEPROM 1 MB Application program memory : FEEPROM 2 MB

PC Card SlotBased on PC Card Standard 95

(Memory card or ATA card, Type l/ll) Max. 32MB

GTS-821ABoth sides GTS-822A : One side GTS-823A : One side GTS-825A : One side
Show 4 more labels / short text on this page
Optical Plummet Telescope · Optical communication · Computer unit · Display and keyboard
Page 136 of the Topcon GTS-822A user manual — 20 SPECIFICATIONS
Page 136 · click to enlarge
Page 136

20 SPECIFICATIONS

Rechargeable Battery BT-56Q (This battery does not contain mercury) Out put voltage : 7.2 V Capacity : 4.0 Ah

Maximum operating time( when fully recharged) at +20°C (+68°F)

Normal use about 3.5 hours

Distance and Angle measurement about 6 hours

Weight0.4kg (0.9 lbs)

Battery Charger BC-27BR / BC-27CR Input voltage : AC 120V(BC-27BR), AC 230V(BC-27CR) Frequency : 50/60Hz Recharging time (at +20°C /+68°F)

Rechargeable battery BT-56QApprox. 2.5 hours Discharging time (at +20°C /+68°F)

Rechargeable battery BT-56Q : 12 hours (in case of full charge) Operating temperature : +10°C to +40°C ( +50°F to 104°F) Charging signal : Red lamp illumination Refreshing signal : Yellow lamp illumination Finishing signal : Green lamp illumination Weight : 0.4kg (0.9 lbs)

l Battery using time will vary depending on environmental conditions and operations done with GTS- 820A series.

Page 137 of the Topcon GTS-822A user manual — APPENDIX-1
Page 137 · click to enlarge
Page 137

APPENDIX

APPENDIX

1 Dual Axis Compensation

Inclination of the vertical axis with respect to true vertical will result in incorrectly measured horizontal angles. The extent of the error in horizontal angle measurement due to axis tilt depends on three factors :

l the amount of the tilt of axis l the elevation of the target l the horizontal angle between the direction of tilt of the vertical axis and the target.

These factors are related by the following formula :

  • Hz err = V
  • sin α
  • tanh

where v = tilt of axis in arcseconds α = azimuth angle between vert. axis direction and target h = elevation of target Hzerr = error in horizontal angle

Example: When the vertical axis is tilted by 30 arcseconds, the target is 10° above the horizon and

rotated 90° in azimuth from the direction of the vertical axis error.

  • Hz err = 30"
  • sin α
  • tan10° Hz err = 30"
  • 0 . 176326=5.29"

From the above example it can be seen that horizontal angle errors will increase with steeper vertical sights (tangent will increase as vertical angle increases) and will be at a maximum when the target is at right angles (sin 90° =1) to the direction of the vertical axis error. Errors will be at a minimum when the sights are nearly horizontal (h=0, tan0=0) and in the same direction as the vertical axis error (α=0, sin0=0). Please refer to the table below to see the relationship between axis tilt (v) and elevation (h) and the error in horizontal angles which results from these factors.

0° 1° 5° 10° 30° 45°

0" 0" 0" 0"

5" 0" 0.09" 0.44" 0.88" 2.89" 5"

10" 0" 0.17" 0.87" 1.76" 5.77" 10"

15" 0" 0.26" 1.31" 2.64" 8.66" 15"

30" 0" 0.52" 2.62" 5.29" 17.32" 30"

1' 0" 1.05" 5.25" 10.58" 34.64" 1'

APPENDIX-1

h V

Page 138 of the Topcon GTS-822A user manual — APPENDIX-2
Page 138 · click to enlarge
Page 138

APPENDIX

It is clear from the table that dual axis compensation has the most benefit when the elevation of the target is greater then 30° and the axis is tilted more than 10". The entries indicated in bold in the table show, in fact, that for many common surveying applications i.e. target elevation

Even though the compensators can correct horizontal angles for vertical axis errors, it is still important to use care in setting up the instrument. Centering error, for instance, cannot be corrected by the compensators. If the vertical axis is tilted by 1’ with the instrument 1.4meters above the ground, a centering error of approx. 0.4mm will result. The maximum effect of this error at 10m is about 8" of horizontal angle error.

In order to maintain the increased accuracy possible through dual axis compensation, it is necessary to keep the compensators in proper adjustment.The compensators must agree with the actual level condition of the instrument. Through various environmental stresses, the agreement between the level condition sensed by the compensators and the true level condition of the instrument may be disturbed. In order to reestablish the correct relationship between the compensator and the true level condition of the instrument, it is necessary to carry out the vertical indexing procedure listed on Section 9.4“Adjustment of Compensation Systematic Error of Instrument” . This adjustment will both reset the vertical index (cause a direct + indirect zenith reading to the same elevation to equal 360°) and zero the level reference for the horizontal compensator. While correct vertical angles can be obtained by averaging direct and indirect reading even when the index is improperly adjusted, the same is not true for horizontal angles. Since the vertical axis error is fixed for a given setup, its effect cannot be removed by averaging two readings. For this reason, it is extremely important to maintain the vertical indexing adjustment to insure proper correction of the horizontal angles.

APPENDIX-2

Page 139 of the Topcon GTS-822A user manual — APPENDIX-3
Page 139 · click to enlarge
Page 139

APPENDIX

2 Precaution when Charging or Storing Batteries

The capacity of battery will be affected and its service life shortened in any of the following cases while it is recharged, discharged or stored.

1) Recharging Fig. 1 shows how ambient temperature at recharging is related to charging efficiency or as affecting discharge capacity. As seen from the figure, charging at normal temperature is best, and the efficiency decreases as the temperature rises. It is best, therefore, to always recharge the battery at normal temperature to obtain full use of battery capacity and enjoy maximum operation per charge. And the service life of your battery will be shortened if it is frequently overcharged or recharged at high temperature.

2. Discharge Fig. 2 shows discharge temperature characteristics. Discharge characteristics at high temperature are the same as those at normal temperatures. The battery is likely to have reduced discharge capacity as well as lower discharged voltage when discharged at low temperature. And the service life of your battery will be shortened if it is greatly overcharged.

3) Storage See Fig. 3 for how storing period at different temperature levels is related to the remaining capacity. The battery will lose its capacity as storage temperature rises and the storage period increases. This does not mean, however , that the battery performance is damaged when the battery is stored. The battery, reduced in capacity, will be restored once it is recharged. Always recharge your battery before use. And recharge and discharge the battery 3 or 4 times to restore its capacity if it has been stored for a long period or at high temperature. Storing at high temperature can adversely affect the service life of your battery. Your battery has been fully charged before leaving the factory, but its capacity may be affected considerably when it takes several months to reach you, if it is stored at high temperature area or passes through a high-temperature region. Then, the battery must be recharged and discharged 3~4 times to fully restore its capacity. And the battery should always be stored at normal temperature or lower if it will not be used for any long period. This helps your battery have a longer service life.

APPENDIX-3

Page 140 of the Topcon GTS-822A user manual — APPENDIX-4
Page 140 · click to enlarge
Page 140

APPENDIX

Charging efficiency (discharge capacity

0.1C charge

Discharge0.2, E.V.= Temperature at
discharge20

0 10 20 30 40 50 60

Ambient temperature when charging i j

Fig.1 Recharging

Discharge capacity i j

0.2C discharge

Charging0.1C ~16hours Charging temperature : 20

Ambient temperature i j

Fig. 2 Discharge

Remaining capacity ratio i j

Charging0.1C ~16hours Discharge : 0.2 C, E.V.=1.0V

Fig. 3 Storage

APPENDIX-4

1C discharge · 0 20 40 · Storing period (month)

Page 141 of the Topcon GTS-822A user manual — APPENDIX WARRANTY AND SPECIAL PROVISIONS
Page 141 · click to enlarge
Page 141

END USER LICENSE AGREEMENT IMPORTANT-- READ CAREFULLY BEFORE USING THE EMBEDDED SYSTEM WHICH CONTAINS MI- CROSOFT SOFTWARE. By using the embedded system containing software, you indicate your acceptance of the following Software License Agreement.

SOFTWARE LICENSE AGREEMENT

(Embedded Products) This software license agreement, including the Warranty and Special Provisions set forth in the appendix or sep- arate booklet included in this package, is a legal agreement between you (either an individual or an entity, here- inafter "End User") and the manufacturer ("Embedded System Manufacturer") of the embedded system containing software product. By using the embedded system on which software program(s) have been pre installed ("SOFT- WARE"), you are agreeing to be bound by the terms of this agreement.

1.GRANT OF LICENSE. This License Agreement permits you to use the Microsoft SOFTWARE as preinstalled on the embedded system.

2. INTELLECTUAL PROPERTY. GTS-820A SERIES contains intellectual property, i.e., software programs, that is licensed for the end user customer's use (hereinafter "End User"). This is not a sale of such intellectual property. The End User shall not copy, disassemble, reverse engineer, or decompile the software program.

3.COPYRIGHT. The SOFTWARE is owned by Microsoft Corporation or its suppliers and is protected by United States copyright laws and international treaty provisions and all other applicable national laws. Therefore, you must treat the SOFTWARE like any other copyrighted material.

4.U.S. GOVERNMENT RESTRICTED RIGHTS. The SOFTWARE and documentation are provided with RE- STRICTED RIGHTS. Use, duplication, or disclosure by the United States Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of The Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 or subparagraphs (c)(1) and (2) of the Commercial Computer Software -- Restricted Rights at 48 CFR 52.227-19, as applicable. Manufacturer is Microsoft Corporation/One Microsoft Way/Redmond, WA 98052- 6399.

Please see the Warranty and Special Provisions for information concerning governing law.

Product support for the SOFTWARE is not provided by Microsoft Corporation or its subsidiaries. For product sup- port, please refer to Embedded System Manufacturer's support number provided in the documentation for the em- bedded system. Should you have any questions concerning this Agreement, or if you desire to contact Embedded System Manufacturer for any other reason, please refer to the address provided in the documentation for your embedded system.

FOR THE LIMITED WARRANTY AND SPECIAL PROVISIONS PERTAINING TO YOUR COUNTRY, PLEASE REFER TO EMBEDDED SYSTEM DOCUMENTATION OR THE WARRANTY AND SPECIAL PROVISIONS BOOKLET INCLUDED IN THIS PACKAGE.

APPENDIX WARRANTY AND SPECIAL PROVISIONS

LIMITED WARRANTY

LIMITED WARRANTY. Embedded System Manufacturer warrants that (a) the SOFTWARE will perform substan- tially in accordance with the accompanying written materials for a period of ninety (90) days from the date of re- ceipt. Any implied warranties on the SOFTWARE are limited to ninety (90) days. Some states/jurisdictions do not allow limitations on duration of an implied warranty, so the above limitation may not apply to you.

CUSTOMER REMEDIES. Embedded System Manufacturer's and its suppliers' entire liability and your exclusive remedy shall be, at Embedded System Manufacturer's option, either (a) return of the price paid, or (b) repair or replacement of the SOFTWARE that does not meet the above Limited Warranty and which is returned to Embed- ded System Manufacturer with a copy of your receipt. This Limited Warranty is void if failure of the SOFTWARE has resulted from accident, abuse, or misapplication. Any replacement SOFTWARE will be warranted for the re- mainder of the original warranty period or thirty (30) days, whichever is longer.

NO OTHER WARRANTIES. THE MICROSOFT SOFTWARE PROGRAMS ARE PROVIDED TO THE END USER "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE ENTIRE RISK OF THE QUALITY AND PERFORMANCE OF THE SOFTWARE PROGRAM IS WITH YOU. NO LIABILITY FOR CONSEQUENTIAL DAMAGES. EMBEDDED SYSTEM MANUFACTURER'S AND ITS SUP- PLIERS' SHALL NOT BE HELD TO ANY LIABILITY FOR ANY DAMAGES SUFFERED OR INCURRED BY THE END USER (INCLUDING, BUT NOT LIMITED TO, GENERAL, SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION AND THE LIKE), ARISING FROM OR IN CONNECTION WITH THE DELIVERY, USE OR PERFORMANCE OF THE SOFTWARE PROGRAM.

SPECIAL PROVISIONS This Software License Agreement and Warranty are governed by the laws of the State of Washington, U.S.A.

Page 142 of the Topcon GTS-822A user manual — 20 SPECIFICATIONS
Page 142 · click to enlarge
Page 142

EMC NOTICE In industrial locations or in proximity to industrial power installations, this instrument might be affected by electromagnetic noise. Under such conditions, please test the instrument performance befor use.

This is a CLASS A product. Ina domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Page 143 of the Topcon GTS-822A user manual — 20 SPECIFICATIONS
Page 143 · click to enlarge
Page 143
Page 143 of the Topcon GTS-822A user manual — 20 SPECIFICATIONS
Page 144 of the Topcon GTS-822A user manual — TOPCON CORPORATION
Page 144 · click to enlarge
Page 144

AUTO TRACKING TOTAL STATION GTS-820A series

TOPCON POSITIONING SYSTEMS, INC.

TOPCON SOUTH ASIA PTE. LTD.

5758 West Las Positas Blvd., Pleasanton, CA 94588, U.S.A. Phone: 925-460-1300 Fax: 925-460-1315 www.topcon.com TOPCON CALIFORNIA 3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A. Phone: 916-374-8575 Fax: 916-374-8329 TOPCON EUROPE B.V.

Blk 192 Pandan Loop, #07-01 Pantech Industrial Complex, Singapore 128381 Phone: 62780222 Fax: 62733540 www.topcon.com.sg TOPCON AUSTRALIA PTY. LTD.

408 Victoria Road, Gladesville, NSW 2111, Australia Phone: 02-9817-4666 Fax: 02-9817-4654 www.topcon.com.au TOPCON INSTRUMENTS (THAILAND) CO., LTD.

Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands. Phone: 010-4585077 Fax: 010-4585045 www.topconeurope.com

77/162 Sinn Sathorn Tower, 37th Fl., Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand. Phone: 02-440-1152~7 Fax: 02-440-1158 TOPCON INSTRUMENTS (MALAYSIA) SDN. BHD.

IRELAND OFFICE Unit 69 Western Parkway Business Center

Lower Ballymount Road, Dublin 12, Lreland

Phone01460-0021 Fax: 01460-0129

Excella Business Park Block C, Ground & 1st Floor, Jalan Ampang Putra, Taman Ampang Hilir, 55100 Kuala Lumpur, MALAYSIA Phone: 03-42701068 Fax: 03-42704508 TOPCON KOREA CORPORATION

TOPCON DEUTSCHLAND G.m.b.H.

Giesserallee 31, 47877 Willich, GERMANY Phone: 02154-885-100 Fax: 02154-885-111 [email protected] www.topcon.de TOPCON S.A.R.L.

2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea. Phone: 82-2-2055-0321 Fax: 82-2-2055-0319 www.topcon.co.kr TOPCON OPTICAL (H.K.) LIMITED

89, Rue de Paris, 92585 Clichy, Cedex, France. Phone: 33-1-41069490 Fax: 33-1-47390251 [email protected] TOPCON ESPAÑA S.A.

2/F., Meeco Industrial Bldg., No. 53-55 Au Pui Wan Street, Fo Tan Road, Shatin, N.T., Hong Kong Phone: 2690-1328 Fax: 2690-2221 www.topcon.com.hk TOPCON CORPORATION BEIJING OFFICE

Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern, Barcelona, Spain. Phone: 93-473-4057 Fax: 93-473-3932 www.topconesp.com TOPCON SCANDINAVIA A. B.

Room 8A Poly Plaza Building, 14 Dongzhimen Nandajie, Dongcheng District, Beijing, 100027, China Phone: 10-6501-4191~2 Fax: 10-6501-4190 TOPCON CORPORATION BEIRUT OFFICE

ölndal, SWEDEN Phone: 031-7109200 Fax: 031-7109249 TOPCON (GREATBRITAIN) LTD.

P. O. BOX 70-1002 Antelias, BEIRUT-LEBANON. Phone: 961-4-523525/961-4-523526 Fax: 961-4-521119 TOPCON CORPORATION DUBAI OFFICE

Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K. Phone: 44-1635-551120 Fax: 44-1635-551170 survey.sales@topcon.co.uk laser.sales@topcon.co.uk

C/O Atlas Medical FZCO., P. O. Box 54304, C-25, Dubai Airport Free Zone,UAE Phone: 971-4-2995900 Fax: 971-4-2995901

TOPCON CORPORATION

75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan Phone: 3-3558-2520 Fax: 3-3960-4214 www.topcon.co.jp

64545 90020 GTS-820A Series A 0311 (1A)

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
E31Displayed when the unit of the angle at the recall mode is different from the unit stored in setting mode.Make the unit in same unit system. p.129
E35Displayed when REM measurement carried out to the range from zenith or nadir ± 6° .Operate in the range out of ± 6° from the zenith or nadir. p.129
E36Displayed when the N.E coordinates are set same as the instrument coordinate in setting direction angle or lay out mode.Set except the instrument coordinate value. p.129
E60’sAny abnormality occurs with EDM (distance measuring system).Repair is required. p.129
E71Displayed when Vertical angle 0 position is set with incorrect procedure.Confirm the procedure and readjust. p.129
E72Displayed when Vertical angle -position is adjusted in wrong position.Confirm the procedure and readjust p.129
E73The instrument was not leveled when Vertical angle 0-position is adjusted.Level the instrument then carry the adjustment work. p.129
E81 E82Mainly at the time data transmission between GTS-820 series and external instrument.Press [F1](EXIT) key, and confirm the connection cables are correct. p.129
Other E80‘sData transmission error between internal P.C.B.‘s.Restart and confirm the operation procedure is correct. p.129
E90‘sAbnormality in internal memory system.Repair is required. p.129
E300‘sAbnormality in tracking system.Repair is required. p.129
E600‘sAbnormality in angle measuring system.If this error code continues to display, repair is required. p.129
E700‘sAbnormality in angle measuring system.If this error code continues to display, repair is required. p.129
E800‘sIn the self checking mode, vibration is too big.Get rid of the Vibration p.129

Ask about the Topcon GTS-822A

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Topcon GTS-822A

Be the first to ask — other owners or our team will answer.

Original document

Topcon GTS-822A manual PDF

144 pages·3.6 MB·Telescope·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…