MODEL TMHPE, TMPHF
Installation and
Operation Instructions
2M-Z12999 Rev. - Oct. 1, 2009
TMHPF
is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.

These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual ac- companying the appliance.
Toastmaster reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifications contained in this sheet are subject to change without notice. While Toastmaster exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to ensure a faster service.
Authorized Service Agent Reference the listing provided with the unit
Model No.
Serial No.
for an updated listing go to:
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
E-mail Parts@star-mfg.com Service@star-mfg.com Warranty@star-mfg.com

CAUTION
This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.
The Toastmaster models TMHPE & TMHPF Electric Hot Plates are equipped for the voltage indicated on the nameplate mounted on the front panel. This unit is designed to operate on alternating current (A.C.), two wire single phase service only. DO NOT CONNECT TO DIRECT CURRENT (D.C.).
INSTALLATION For your protection, we recommend that a qualified electrician install this appliance. The electrician should be familiar with electrical installations and your local electrical requirements. The external wiring should be in conduit or an approved type of flexible cable and of suitable size to carry the load. The supply circuit should be properly fused and equipped with a means of disconnecting as required by local electrical code. The body of the hot plate should be grounded (Do not ground to a gas supply pipe). The connections are made in this unit at the pigtail leads located in the junction box on the back of the unit. To gain access to the pigtail leads remove cover on junction box.
LOCATE THE UNIT Do not install the unit closer than 1 inch from a side wall and/or closer than 1 inch from a rear wall.
LEVELING UNIT Level unit by adjusting the (4) feet for accurate and perfect line up with other Toastmaster series units.
DO NOT INSTALL WITHOUT FEET.
USE ONLY FLAT BOTTOM PANS AND POTS! DO NOT USE RAISED BOTTOM UTENSILS OR BUCKETS! GOOD HEAT TRANSFER DEPENDS UPON GOOD CONTACT BETWEEN THE ELEMENT AND POT.
NOTE: Using a 12” diameter or larger pan/pot may cause damage to the element or internal wiring. Such damages are not covered by warranty. Two (2) heating elements are used. For the TMHPF each element draws 2,600 Watts on 240 Volts and 1,950 Watts on 208 Volts. For the TMHPE element draws 2,100 Watts on 240 Volts and 1,575 Watts on 208 Volts. Each element is controlled by an infinite position switch. The right control knob controls the rear cooking element and the left control knob controls the front cooking element. On “HI” the element delivers uninterrupted full heat. Between “LO” and “5” any desired amount of heat can be obtained between 6% and 60% of full heat.
Signal lights are provided above the control knobs to give a visual check if either one or both heating units are turned on.

CLEANING The exterior surfaces can be kept clean and attractive by regularly wiping with a clean soft cloth. Any discoloration can be removed with a non-abrasive cleaner.
For model TMPHE, the heating elements may be raised for access to the drip pans, which may be removed for cleaning and the bottom pan may be removed by sliding pan forward.
BE SURE POWER IS DISCONNECTED BEFORE ATTEMPTING TO SERVICE UNIT.
MAINTENANCE AND REPAIRS Contact the factory or one of its representatives or a local service company for service or maintenance if required.

This warranty is effective on all Toastmaster equipment sold on or after July 1, 2006, and supersedes all previous warranties.
Toastmaster warrants equipment that it manufactures to be free from defects in material and workmanship. Toastmaster’s obligation is limited to repairing or replacing, at Toastmaster’s option, without cost to the customer, any part found to be defective, as well as any labor or material expense required to replace the part.
Length of Warranty This warranty is effective for a period of 18 months from the date of shipment from Toastmaster,
or 12 months from the date of purchase by the end user, whichever is earlier.
Toastmaster reserves the right to change the design and specifications of this equipment or any related documentation at any time. The end user is not entitled to upgrades resulting from these changes.
This warranty is exclusive and supersedes all other warranties for the equipment, both expressed and implied. There are no implied warranties of merchantability or of fitness for a particular purpose.
The foregoing is Toastmaster’s sole and exclusive obligation and the end user sole and exclusive remedy for any action including breach of contract or negligence. In no event shall Toastmaster be liable for a sum in excess of the purchase price of the equipment, or for any prospective or lost profits of the end user.
is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.



TMHPE, TMHPF, Electric Hotplates MODEL

Some items are included for illustrative purposes only and in certain instances may not be available.
is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.

TMHPE/TMHPF SK1986-1
DESCRIPTION OF CHANGE
FOR AT LEAST 90 DEG. C (194 DEG. F)
USE COPPER WIRE ONLY, SUITABLE
Y
PART NO.
PILOT
LIGHT
MODEL NO.
TITLE
240 V (1 PH)
FRONT CONTROL
BACK CONTROL
NOMINAL AMPS PER LINE
#10 AWG
NO REPRODUCTION OR DISCLOSURE OF ITS CONTENTS IS PERMITTED. THIS DRAWING CONTAINS CONFIDENTIAL INFORMATION
P
1 1 H
TMHPE
RIGHT
LEFT
208 V (1 PH)
H1
H2
H2
AWG
240 V (1 PH)
#10 AWG
NOMINAL AMPS PER LINE
TMHPF
MATERIAL
FINISH
208 V (1 PH)
FRONT ELEMENT
BACK ELEMENT
FRACTIONS ± 1/64 DECIMALS ± .005 ANGLES ± 1° TOLERANCES UNLESS OTHERWISE NOTED
ST. LOUIS, MO. 63143, USA
#10 SUNNEN DRIVE
RATED WATTAGE RATED WATTAGE
4200 (240V)
3150 (208V)
USE GA. SHOWN (OR LARGER) FOR SUPPLY CONNECTI0NS
TMHPF TMHPE
DR. CK. DATE
5200 (240V)
3900 (208V)
#12 ·