These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
Toastmaster reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
Due to periodic changes in designs, methods, procedures, policies and regulations, the specifications contained in this sheet are subject to change without notice. While Toastmaster exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications. By using the information provided, the user assumes all risks in connection with such use.
MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to ensure a faster service.
Authorized Service Agent Listing Reference the listing provided with the unit
Model No.
Serial No.
for an updated listing go to:
Business 8:00 am to 4:30 p.m. Central Standard Time Hours:
E-mail Parts@star-mfg.com Service@star-mfg.com Warranty@star-mfg.com

GENERAL INSTALLATION DATA This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.
This gas appliance is equipped for the types of gas indicated on the nameplate mounted on the front panel. It is shipped adjusted for use on natural gas.
The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. KEEP THE APPLIANCE AREA CLEAR AND FREE FROM COMBUSTIBLES.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG. For your protection, we recommend a qualified installing agency install this appliance. They should be familiar with gas installations and your local gas requirements. In any case, your gas company should be called to approve the final installation. In addition, there should be posted, in a prominent location, detailed instructions to be followed in the event the operator smells gas. Obtain the instructions from the local gas supplier.
LEVELING UNIT Units are shipped with feet detached. To attach feet, remove the grates, lay unit on it's side and screw feet into sockets on bottom. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" for accurate and perfect line-up with other Star-Max series units.
DO NOT REMOVE FEET.
GAS PIPING Gas piping shall be new, clean and of such size and so installed as to provide a supply of gas sufficient to meet the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to determine if it has adequate capacity. Joint compound (pipe dope) shall be used sparingly and only on the male threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases. WARNING: Any loose dirt or metal particles which are allowed to enter the gas lines on the appliance will damage the automatic valve and affect its operation. When installing this appliance, all pipe and fittings must be free from all internal loose dirt.

CLEARANCE Minimum wall clearances for the sides and back of the models contained in this manual shall be as follows:
PRESSURE REGULATOR A convertible pressure regulator set at 6" water column for use on natural gas is furnished. (For LP models the regulator is set for 10" water column pressure.) Attach the regulator to the supply pipe, located at the back of the unit, make sure gas flow arrow on regulator is pointing towards manifold. The gas supply is then connected to the regulator. A 1/8" tap is furnished on the manifold for checking pressure. The manifold is accessible by removing the front panel.
MANUAL SHUT OFF VALVE A manual shut off valve should be installed upstream from the unit and within six feet of the appliance, and is not provided.
CONNECTING GAS SUPPLY LINE The gas inlet on this appliance is sealed at the factory to prevent entry of dirt. Do not remove this seal until the actual connection is made to the gas supply line.
CHECKING FOR GAS LEAKS Soap and water solution or other material acceptable for the purpose, shall be used in locating gas leakage. Matches, candle flame or other sources of ignition shall not be used for this purpose.
AIR SUPPLY Provisions for adequate air supply must be furnished.
AIR INTAKES IN BOTTOM Make certain the air intake openings in the bottom of the appliance are not obstructed. They are essential for proper combustion and operation of the appliance.
EXHAUST CANOPY It is essential that facilities be provided to carry off fumes and gases.
GAS INPUT OF OPEN TOP RANGES For Natural Gas: Regulator output pressure set at 6" water column.
For Propane Gas: Regulator output pressure set at 10" water column.

LIGHTING INSTRUCTIONS The appliance is equipped with standing pilots; each pilot is located in front of the burner on Models TMHP2, TMHP6. Pilots should be lighted immediately after the gas is turned on by the manual shutoff valve.

3 The pilot valves are located on the manifold installed at the front of the unit behind the front panel. For access to the valves
ADJUSTING UNIT FOR USE ON PROPANE GAS Units are shipped with orifices and pressure regulator for operation with natural gas (6" water column). To convert unit from natural to propane gas follow these instructions
a. Remove grates and burners.
b. Remove orifices from the manual valves and from fittings on extended gas pipes, replace with the propane
orifices.
c. Install burners and grates.
OPERATING PROCEDURE Each burner will deliver up to 22,000 BTU/HR of heat on all models and is controlled by a manual On/Off valve. The right control knob controls the front burner and the left control knob controls the rear burner on all models. After the pilot is once lit and adjusted, the burners will ignite automatically by turning the control knob to any position between On and Off.
CLEANING THE EXTERIOR (Stainless Steel Only) The exterior surface can be kept clean and attractive by regularly wiping it with a clean soft cloth. Any discoloration can be removed with a non-abrasive cleaner. The burner grates and trough tray can be removed for cleaning.
MAINTENANCE AND REPAIRS Contact the factory or one of its representatives or a local service company for service or maintenance if required.




Some items are included for illustrative purposes only and in certain instances may not be available.
is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.


Some items are included for illustrative purposes only and in certain instances may not be available.
is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.

This warranty is effective on all Toastmaster equipment sold on or after July 1, 2006, and supersedes all previous warranties.
Toastmaster warrants equipment that it manufactures to be free from defects in material and workmanship. Toastmaster’s obligation is limited to repairing or replacing, at Toastmaster’s option, without cost to the customer, any part found to be defective, as well as any labor or material expense required to replace the part.
Length of Warranty This warranty is effective for a period of 18 months from the date of shipment from Toastmaster,
or 12 months from the date of purchase by the end user, whichever is earlier.
Toastmaster reserves the right to change the design and specifications of this equipment or any related documentation at any time. The end user is not entitled to upgrades resulting from these changes.
This warranty is exclusive and supersedes all other warranties for the equipment, both expressed and implied. There are no implied warranties of merchantability or of fitness for a particular purpose.
The foregoing is Toastmaster’s sole and exclusive obligation and the end user sole and exclusive remedy for any action including breach of contract or negligence. In no event shall Toastmaster be liable for a sum in excess of the purchase price of the equipment, or for any prospective or lost profits of the end user.