SAFETY SYMBOLS

These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance.

CAUTION WARNING

RETAIN THIS MANUAL FOR FUTURE REFERENCE

Toastmaster reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.

Due to periodic changes in designs, methods, procedures, policies and regulations, the specifications contained in this sheet are subject to change without notice. While Toastmaster exercises good faith efforts to provide information that is accurate, we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications. By using the information provided, the user assumes all risks in connection with such use.

MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance. Please record the model number, serial number, voltage and purchase date in the area below and have it ready when you call to ensure a faster service.

Authorized Service Agent Listing Reference the listing provided with the unit

Model No.

Serial No.

for an updated listing go to:

Websitewww.star-mfg.com E-mail Service@ star-mfg.com Telephone: (800) 264-7827 Local (314) 678-6347

The Service Help Desk

Business 8:00 am to 4:30 p.m. Central Standard Time Hours:

Telephone(800) 264-7827 Local (314) 678-6347
Fax(800) 396-2677 Local (314) 781-2714

E-mail Parts@star-mfg.com Service@star-mfg.com Warranty@star-mfg.com

Websitewww.star-mfg.com
Mailing AddressToastmaster 10 Sunnen Drive St. Louis, MO 63143 U.S.A
Show 4 more labels / short text on this page
or · Voltage · Purchase Date ·
Page 3 of the Toastmaster THMP2 user manual — CAUTION
Page 3 · click to enlarge
Page 3

GENERAL INSTALLATION DATA This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. For equipment to be used by the general public, please contact the factory.

CAUTION

This gas appliance is equipped for the types of gas indicated on the nameplate mounted on the front panel. It is shipped adjusted for use on natural gas.

The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.

IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. KEEP THE APPLIANCE AREA CLEAR AND FREE FROM COMBUSTIBLES.

This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG. For your protection, we recommend a qualified installing agency install this appliance. They should be familiar with gas installations and your local gas requirements. In any case, your gas company should be called to approve the final installation. In addition, there should be posted, in a prominent location, detailed instructions to be followed in the event the operator smells gas. Obtain the instructions from the local gas supplier.

LEVELING UNIT Units are shipped with feet detached. To attach feet, remove the grates, lay unit on it's side and screw feet into sockets on bottom. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4" for accurate and perfect line-up with other Star-Max series units.

DO NOT REMOVE FEET.

CAUTION

GAS PIPING Gas piping shall be new, clean and of such size and so installed as to provide a supply of gas sufficient to meet the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall be checked to determine if it has adequate capacity. Joint compound (pipe dope) shall be used sparingly and only on the male threads of the pipe joints. Such compounds shall be resistant to the action of L.P. gases. WARNING: Any loose dirt or metal particles which are allowed to enter the gas lines on the appliance will damage the automatic valve and affect its operation. When installing this appliance, all pipe and fittings must be free from all internal loose dirt.

Page 4 of the Toastmaster THMP2 user manual — Combustible Non-Combustible Wall Wall Hotplates 9" 0"
Page 4 · click to enlarge
Page 4

CLEARANCE Minimum wall clearances for the sides and back of the models contained in this manual shall be as follows:

Combustible Non-Combustible Wall Wall Hotplates 9" 0"

PRESSURE REGULATOR A convertible pressure regulator set at 6" water column for use on natural gas is furnished. (For LP models the regulator is set for 10" water column pressure.) Attach the regulator to the supply pipe, located at the back of the unit, make sure gas flow arrow on regulator is pointing towards manifold. The gas supply is then connected to the regulator. A 1/8" tap is furnished on the manifold for checking pressure. The manifold is accessible by removing the front panel.

MANUAL SHUT OFF VALVE A manual shut off valve should be installed upstream from the unit and within six feet of the appliance, and is not provided.

CONNECTING GAS SUPPLY LINE The gas inlet on this appliance is sealed at the factory to prevent entry of dirt. Do not remove this seal until the actual connection is made to the gas supply line.

CHECKING FOR GAS LEAKS Soap and water solution or other material acceptable for the purpose, shall be used in locating gas leakage. Matches, candle flame or other sources of ignition shall not be used for this purpose.

AIR SUPPLY Provisions for adequate air supply must be furnished.

AIR INTAKES IN BOTTOM Make certain the air intake openings in the bottom of the appliance are not obstructed. They are essential for proper combustion and operation of the appliance.

EXHAUST CANOPY It is essential that facilities be provided to carry off fumes and gases.

GAS INPUT OF OPEN TOP RANGES For Natural Gas: Regulator output pressure set at 6" water column.

For Propane Gas: Regulator output pressure set at 10" water column.

Page 5 of the Toastmaster THMP2 user manual — ADJUSTING BURNERS
Page 5 · click to enlarge
Page 5

LIGHTING INSTRUCTIONS The appliance is equipped with standing pilots; each pilot is located in front of the burner on Models TMHP2, TMHP6. Pilots should be lighted immediately after the gas is turned on by the manual shutoff valve.

1. Turn control knobs to "OFF" position.
Toastmaster THMP2 — ADJUSTING BURNERS diagram (page 5)
Fig. 2
2. Light pilot with a lighted taper.

3 The pilot valves are located on the manifold installed at the front of the unit behind the front panel. For access to the valves

4. Loosen the set screws securing the knobs in position, and remove the knobs. Remove the front panel, which is attached to the frame with 4 sheet metal screws.
5. Turn the adjustment screws on the front of the pilot valves. The pilots should be adjusted to blue short flame (1/4" high) to have good ignition to the burners. Repeat for remaining pilots.
6. If the pilot(s) is out turn off gas, wait 5 minutes and repeat steps (1) through (5).

ADJUSTING BURNERS

7. With control valve for the front burner turned to full "ON" position, close the air shutters to give a soft blue flame having luminous tips and open to a point where the yellow tips disappear, then tighten the locking screws. Repeat this procedure with the remaining burners.
8. Install the front panel to the front of the frame & reconnect and secure the knobs back into position.

ADJUSTING UNIT FOR USE ON PROPANE GAS Units are shipped with orifices and pressure regulator for operation with natural gas (6" water column). To convert unit from natural to propane gas follow these instructions

1. Set regulator outlet pressure to 10" water column. A 1/8" pipe plug on the manifold can be removed for attaching a pressure gauge. Remove the slotted cover from the pressure regulator and invert the plug. Replace the cover on the regulator and plug on the manifold. Regulator is now set at 10" W.C.
2. Remove natural gas orifices, #46 for all models, and install propane orifices, painted black, (#54 for all models except) located in a bag on the outside of the front panel. In order to remove natural gas orifices:

a. Remove grates and burners.

b. Remove orifices from the manual valves and from fittings on extended gas pipes, replace with the propane

orifices.

c. Install burners and grates.

OPERATING PROCEDURE Each burner will deliver up to 22,000 BTU/HR of heat on all models and is controlled by a manual On/Off valve. The right control knob controls the front burner and the left control knob controls the rear burner on all models. After the pilot is once lit and adjusted, the burners will ignite automatically by turning the control knob to any position between On and Off.

CLEANING THE EXTERIOR (Stainless Steel Only) The exterior surface can be kept clean and attractive by regularly wiping it with a clean soft cloth. Any discoloration can be removed with a non-abrasive cleaner. The burner grates and trough tray can be removed for cleaning.

MAINTENANCE AND REPAIRS Contact the factory or one of its representatives or a local service company for service or maintenance if required.

Page 6 of the Toastmaster THMP2 user manual — SK2431 REV - 8/26/09
Page 6 · click to enlarge
Page 6
Toastmaster THMP2 — SK2431 REV - 8/26/09 diagram (page 6)
Fig. 3
MODELTMHP2, TMHP4, TMHP6 Gas Hotplates

SK2431 REV - 8/26/09

Page 7 of the Toastmaster THMP2 user manual — PARTS LIST October 1, 2008, Rev -
Page 7 · click to enlarge
Page 7

PARTS LIST October 1, 2008, Rev -

MODELTMHP2, TMHP4, TMHP6, Gas Hotplates
Toastmaster THMP2 — PARTS LIST October 1, 2008, Rev - diagram (page 7)
Fig. 4 · PARTS LIST October 1, 2008, Rev -
FIG No.Part NoQtyDescriptionApplication 12F-Z06372CASTINGTMHP2 4TMHP4 6TMHP6 22F-Z06152BURNER 7” ROUNDTMHP2 4TMHP4 6TMHP6 32I-Z07522GASKET-BURNERTMHP2 4TMHP4 6TMHP6 4I4-6020141PILOT TUBE ASSY LONGTMHP2 2TMHP4 3TMHP6 5I4-6020131PILOT TUBE ASSY SHORTTMHP2 2TMHP4 3TMHP6 62F-Z07472VENTURI SHORT CASTINGTMHP2 4TMHP4 6TMHP6 72P-14531PLUG-PIPE 1/8NPT SQ HDALL 82J-6020121MANIFOLD ASSEMBLYTMHP2 2J-604002TMHP4 2J-606002TMHP6 92J-Z07921REGULATORTMHP2 10I8-TC00101BASIC ASSY HOTPLATE 12”TMHP2 I8-TC0012BASIC ASSY HOTPLATE 24”TMHP4 I8-TC0014BASIC ASSY HOTPLATE 36”TMHP6 112A-Z03144FOOT, 4 IN DIE CASTTMHP2 12I4-Z60241PAN-12TMHP2 I4-Z6025PAN-24TMHP4 I4-Z6026PAN-36TMHP6 132C-8833ARSCREW 8-18X1/2 HEX STL NPTMHP2 142R-Z130142KNOB, MANUAL GASTMHP2 4TMHP4 6TMHP6 152M-Z129361GRAPHIC PANEL, 12” HTPLTTMHP2 2M-Z12937GRAPHIC PANEL, 24” HTPLTTMHP4 2M-Z12938GRAPHIC PANEL, 36” HTPLTTMHP6 16I4-Z60121FRONT PANEL-12TMHP2 I4-Z6013FRONT PANEL-24TMHP4 I4-Z6014FRONT PANEL-36TMHP6

Some items are included for illustrative purposes only and in certain instances may not be available.

is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.

Page 8 of the Toastmaster THMP2 user manual — PARTS LIST October 1, 2008, Rev -
Page 8 · click to enlarge
Page 8

PARTS LIST October 1, 2008, Rev -

MODELTMHP2, TMHP4, TMHP6, Gas Hotplates
Toastmaster THMP2 — PARTS LIST October 1, 2008, Rev - diagram (page 8)
Fig. 5 · PARTS LIST October 1, 2008, Rev -
Fig No.Part NoQtyDescriptionApplication 172V-Y88322VALVE-MANUAL GASTMHP2 4TMHP4 6TMHP6 182A-Z07901FITTING-STRAIGHTTMHP2 2TMHP4 3TMHP6 192V-66712VALVE-LINCOLN BRASS#3817TMHP2 4TMHP4 6TMHP6 202V-Z08691TUBE 3/8 DIATMHP2 2TMHP4 3TMHP6 212A-Y39611ORIFICE FITTINGTMHP2 2TMHP4 3TMHP6 222A-Y32972,4,6ORIFICE #46 NATALL 2A-Z14552,4,6ORIFICE #54 LPALL 23I8-TC00111FRONT BULLNOSE ASSY 12”TMHP2 I8-TC0013FRONT BULLNOSE ASSY 24”TMHP4 I8-TC0015FRONT BULLNOSE ASSY 36”TMHP6

Some items are included for illustrative purposes only and in certain instances may not be available.

is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.

Page 9 of the Toastmaster THMP2 user manual — Exceptions
Page 9 · click to enlarge
Page 9

Warranty Statement

This warranty is effective on all Toastmaster equipment sold on or after July 1, 2006, and supersedes all previous warranties.

Toastmaster warrants equipment that it manufactures to be free from defects in material and workmanship. Toastmaster’s obligation is limited to repairing or replacing, at Toastmaster’s option, without cost to the customer, any part found to be defective, as well as any labor or material expense required to replace the part.

Length of Warranty This warranty is effective for a period of 18 months from the date of shipment from Toastmaster,

or 12 months from the date of purchase by the end user, whichever is earlier.

Exceptions

  • This warranty is valid only for the original end user owner/operator of the equipment.
  • This warranty does not apply to normal maintenance functions, including (but not limited to) improper operation, installation or the use of an improper utility supply.
  • This warranty is valid only if the equipment is used in a commercial setting. The equipment is designed and constructed for commercial use by trained professionals only. Any use of the equipment in private or domestic applications immediately voids this warranty.
  • This warranty does not apply to any parts, labor and material expenses for service that is not pre-approved and performed by a Toastmaster authorized service agent. Any such service immediately voids this warranty.
  • This warranty does not apply to any parts, labor and material expenses associated with the installation of parts that are not factory-approved for use in the equipment. Any use of such parts immediately voids this warranty.
  • This warranty is not valid if terms of payment have not been met.
  • For warranty service on Pop-up toasters and light countertop equipment, an exchange program would supersede a service call. Please find Warranty Exchange Program’ authorization to follow. (<a href="http://www.toastmastercorp.com/filespdfcat/warranty_exchange_2008.pdf" rel="nofollow noopener" target="_blank">http://www.toastmastercorp.com/filespdfcat/warranty_exchange_2008.pdf</a>)

Toastmaster reserves the right to change the design and specifications of this equipment or any related documentation at any time. The end user is not entitled to upgrades resulting from these changes.

This warranty is exclusive and supersedes all other warranties for the equipment, both expressed and implied. There are no implied warranties of merchantability or of fitness for a particular purpose.

The foregoing is Toastmaster’s sole and exclusive obligation and the end user sole and exclusive remedy for any action including breach of contract or negligence. In no event shall Toastmaster be liable for a sum in excess of the purchase price of the equipment, or for any prospective or lost profits of the end user.

is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.

Page 10 of the Toastmaster THMP2 user manual — Warranty Statement
Page 10 · click to enlarge
Page 10
Page 10 of the Toastmaster THMP2 user manual — Warranty Statement
Page 11 of the Toastmaster THMP2 user manual — Warranty Statement
Page 11 · click to enlarge
Page 11
Page 11 of the Toastmaster THMP2 user manual — Warranty Statement
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Toastmaster THMP2

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Toastmaster THMP2

Be the first to ask — other owners or our team will answer.

Original document

Toastmaster THMP2 manual PDF

16 pages·2.1 MB·Food Warmer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…