E6UAC E6UAC-INS



GENERAL INFORMATION The E17UAC or E6UAC will hold food hot at a constant temperature, and supply humidity for proofing when the application applies. This cabinet is not a cooking appliance. UNPACKING - Examine the interior of the unit to make sure all packing materials are removed before the unit is plugged into an electrical outlet. Examine the interior and exterior to determine whether any damage was incurred during delivery. If so, notify the carrier immediately to file a damage claim. All Wilder equipment is carefully tested and inspected prior to shipment. When accepted for delivery by carrier, the responsibility for safe arrival at the destination is assumed by the carrier. CAUTION: Should any damage be found, do not attempt to operate the unit. Call your dealer immediately to arrange for service. MAINTENANCE - The equipment has been designed to require minimum maintenance and has been constructed to meet National Sanitation Foundation and U.S. Public Health Service Standards. Non-toxic chemical cleaners or mild detergents are recommended for cleaning of fixtures. Do not use steel wool of any kind. Steel wool particles will work into the grains of the metal causing corrosion. Also, these particles can cause a health hazard. Should scouring be required, use a non-abrasive type of cleaner. Do not use caustic solutions on your equipment. Hosing or steaming should not be necessary to keep these fixtures clean and sanitary. Do not allow water or steam to come into contact with electrical components. CAUTION: Be sure to disconnect power source before cleaning and servicing the unit. Liability for improper or careless use is the responsibility of the equipment owner or persons servicing the unit, including the authorized service agent.

6. Adjust the heat and humidity thermostat knobs to control desired temperature and humidity. Allow 45 minutes for pre-heating. NOTE: The internal air circulation blower will operate continuously when the power switch is turned “on”. HEAT THERMOSTAT - The controlling range is 80°F to 175°F. The dial has numbers 1 through 9 that do not relate to specific calibrated temperatures. Temperature settings must be obtained through familiarization with the unit. The dial has an “off” position to turn heater unit off. HUMIDITY THERMOSTAT - To control humidity range from 30% to 100% humidity, settings must be obtained through familiarization with the unit. The dial also has an “off” position to turn heater unit off. To maintain low heat range between 85°F and 100°F, switch to proof mode and adjust heat knob to desired heat range. Allow 45 minutes to pre-heat in proof cycle.

1 Heat/Proof Switch 2E-50-1357
2 Thermostat (Heat) 2T-66-1158
3 Thermostat (Proof) 2T-66-1158
4 Blower and Motor Assy 2U-WP-6FANS30P
5 Pilot Light 2J-50-0029-A
6 Main Power Switch 2E-50-1355
7 Snap Disc 2T-66-1150
8 Pan Slide 25-0010-C
9 800W Heater Element, Export Models (50Hz only) 2N-60-0200
10 1100W Heater Element 2N-60-0201
11 600W Heater Element 2N-6WH0001P
12 600W Water Pan Heater Element 2N-6FME755P
13 Proof and Heat Control Knob 2R-50-0726
14 Corner Bumpers 2R-4FMBC01P
15 5” Caster E17UAC 305SSPWH
16 3” Caster E6UAC 2P-50-1388
17 Lexan Door Assy E17UAC (mfg before 10/2008) R2-WASSY043 WASSY043 Door Gasket 2I-70-0359A
17 Lexan Door Assy E17UAC (mfg after 10/2008) R2-WASSY058 WASSY058 Door Gasket 2I-70-0363A
17 Lexan Door E17UAC-INS R2-WASSY058
17 Lexan Door E6UAC R2-WASSY046
17 Lexan Door E6UAC-INS WASSY048
18 S/S Hinge 2F-50-1209-A
17 Cord 5-15P 2E-50-1275
17 Cord 5-20P 2E-50-0375
-- Assy, Water pan No-Elements R2-WASSY082
-- Handle & Magnet Latch (on door) 2R-50-1319
-- Catch Bracket (on cabinet) R2-06-0160

E17UAC Heater Proofer



SERVICE SPECIFICATIONS – E17UAC The Heater Proofer is an aluminum transport cabinet with heaters to function as a hot food holding cabinet, and/or as a proofing cabinet. The heater, or heat drawer, is slid into place on the floor of the cabinet. An electrical socket on the back of the drawer is provided to accept the supplied power cord, which is plugged into the drawer through an access hole in the back of the cabinet. The main power switch on the front of the drawer, when switched “ON”, will turn on the light in the switch and turn on the air circulating fan in the drawer. The circulating fan will operate continuously while the unit is “ON”. The thermostat control knobs are mounted to the left and right of the heat/proof switch. The left thermostat knob controls the heat in the cabinet from 1 (low heat: approximately 80°F) to 9 (high heat: approximately 175°F). The right thermostat knob controls the humidity from 1 (approximately 20% relative humidity) to 9 (in excess of 100% relative humidity). Average setting will be approx. 6 (approximately 85% relative humidity). TROUBLE SHOOTING - Caution: Before disassembling unit, electrical power must be disconnected by unplugging the unit. Failure to unplug the unit prior to servicing may result in electrical shock.
Each unit is shipped with an instruction manual to be used as a reference guide for all service areas. The manual shows a picture of the drawer, showing the location of electrical components and a description of each. If the unit does not operate correctly, or malfunctions for any reason, the following checklist should provide a solution.

EQUIPMENT WARRANTY NU-VU Food Service Systems and Toastmaster Manufacturing warrant to the initial purchaser that all NU-VU and Toastmaster products shall be free from defects in material or factory workmanship, under ordinary use for the purpose for which it is designed, for a period of one (1) year from the date of shipment from the manufacturing facility. At our option, any equipment will be repaired or a replacement part furnished FOB our factory. Return of component parts will not be accepted for credit without prior authorization by our service department, and then contingent upon our inspection. This Warranty will not apply if, after examination, it is determined that the equipment or any part thereof is found to be defective through purchaser’s lack of responsibility for maintenance or storage, shipping damage, accidental damage by moving or otherwise, improper voltage, misapplication or alteration by other than ourselves, or use of unauthorized parts. This Warranty does not apply to glass, light bulbs, or gaskets. This Warranty does not apply if payment has not been received for the equipment at the time a claim is made or if the NU-VU or Toastmasater serial number has been removed. WARRANTY EXCLUSIONS AND LIMITATIONS This Warranty applies only within the United States and Canada. ANY IMPLIED WARRANT OF MERCANTABLITY OR FITNESS FOR A PARTICULAR PURPOSE IS HERERBY SPECIFICALLY DISCLAIMED BY NU-VU/Toastmaster. There are no warranties, expressed or implied, which extend beyond the description on the face thereof. This warranty does not cover, and NU-VU/Toastmaster shall not under any circumstances be liable for, any incidental, consequential or other damages (such as injury to persons or property, loss of time, inconvenience, loss of use, loss of business or profits, or other matters not specifically covered) arising in connection with the use of, inability to use, or failure of these products. Star International Holding Inc. Company 10 Sunnen Dr St. Louis, MO 63143 Phone:800-264-7827 Fax: 314-781-2714