Instruction/ maintenance manual of the product VF4000-CMP-2 TOA Electronics
Go to page of 20
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 1 Unvented Decorative Gas Fireplaces P/N 903590 REV. N 12/2007 VF4000-CHN-2 VF4000-CHP-2 VF4000-CMN-2 VF4000-CMP-2 MODELS FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS. DO NOT BUILD A WOOD FIRE.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 These heaters are manually controlled. Models VF4000-CMN-2 and VF4000-CMP-2 feature a gas valve incorporating a millivolt operating system.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 Your options are: a. Rework equations adding the space of ad- joining room(s). If the extra volume provides an unconfined space, then remove door or add ventilation grills between rooms. Refer to National Fuel Gas Code, ANSI Z223.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 Ensure the minimum clearances shown in Figures 2 and 3 are maintained. Minimum clearance to combustibles are: Appliance: side and back - 0" floor - 0" adjacent wall - 6" ceiling - 37-1/2” (953 mm) Figure 2 A hearth extension is not required with this appliance.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 The gas control valve is located in the lower control compartment. To access the valve open the lower control compartment door ( Figure 9 ). The regulator has a 3/8" NPT thread inlet port and is fitted with a 3" (76 mm) long nipple, ³⁄₈ " NPT on both ends.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 Figure 12 White (Supply) Black (Supply) Bipolar T erminal Screw Blower (Lower) Outlet Black Wire Mating Connectors Red Wire 120 Vac 60 Hz Blower Wirin.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Figure 14 Note: The heater may be installed directly on a floor made of standard combustible wood con- struction materials. Do not install the heater directly on carpeting or other soft floor cover- ing such as vinyl tile or flooring materials.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 To light the burner; rotate the gas valve control knob counterclockwise to the “ON” position. Step 14. Installing the Hood Assembly – Attach the hood assembly over the firebox opening with three (3) screws.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 Grounded to Appliance Blower Motor Motor Plug Receptacle 120V Appliance Junction Box Figure 20 Brass Louver Kit Brass louvers are available for use with these appliances. These louvers are designed to replace the standard black louvers that are provided with the appliance.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 OPERATION AND CARE OF YOUR APPLIANCE 1. Blower operation may be controlled through the ON/OFF unit rocker switch, located in the lower control compartment. 2. These heater rated units are equipped with a two stage (HI, LOW) gas control valve.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 Gas Flex Line Kit FFGC Refractory Liner Kit VF5RLK Decorative Volcanic Stone FDVS Wood Surround-Wa.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 VF4000 SPECIFICATIONS Figure 21 37" (940 mm) 36" (914 mm) 30" (762 mm) 31-1/2" (800 mm) 15" (381 mm) Front View Left Side Vi.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 VF4000-CHM/P OPERATING INSTRUCTIONS (STANDARD VALVES) FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. Stop! Read the safety information above. 2. Make sure manual shut-off valve is fully open.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 Figure 22 Pilot Location Figure 23 Pilot Turn Control Knob to “OFF” Position Figure 24 Turn Control Knob to “IGN” Position O F F I G N L O W .
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 VF4000-CMN/P OPERATING INSTRUCTIONS (MILLIVOLT VALVES) FOR YOUR SAFETY READ BEFORE LIGHTING • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 1. When igniter button is pressed, there is no spark at ODS/pilot. 2. Heater produces unwanted odors. 3. Heater shuts off in use (ODS operates). 4. Gas odor even when control knob is in “OFF” position.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 REPLACEMENT PARTS LIST VF4000-CHN (Manual) VF4000-CMN (Millivolt) VF4000-CHP (Manual) VF4000-CMP (Millivolt) No.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 REPLACEMENT PARTS 9 10 15 14 4 7 6 5 12 1 12 13 13 2 8 3 CH Models CM Models CH Models CM Models (SIT Valve Shown) 11.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 Printed in U.S.A. © 1997 by Lennox Hearth Products P/N 903590 REV. N 12/2007 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
An important point after buying a device TOA Electronics VF4000-CMP-2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought TOA Electronics VF4000-CMP-2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data TOA Electronics VF4000-CMP-2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, TOA Electronics VF4000-CMP-2 you will learn all the available features of the product, as well as information on its operation. The information that you get TOA Electronics VF4000-CMP-2 will certainly help you make a decision on the purchase.
If you already are a holder of TOA Electronics VF4000-CMP-2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime TOA Electronics VF4000-CMP-2.
However, one of the most important roles played by the user manual is to help in solving problems with TOA Electronics VF4000-CMP-2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device TOA Electronics VF4000-CMP-2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center