Instruction/ maintenance manual of the product Models from 8 kW to 24 kW : 240 Volts ( single phase ) Thermo Products
Go to page of 24
MC COMBOMAX Electric boiler with integrated instantaneous water heater Models from 8 kW to 24 kW : 240 Volts ( single phase ) Use and Care Manual With installation instructions for the contractor Your COMBOMAX ® electric boiler has been carefully assembled and factory tested to provide years of trouble-free service.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 2. Section 1 : Technical specifications Table 1: Boiler specifications 240 Vac (single phase) : Pow er Nominal load.
13 6 5 10 12 3 16 8 9 F 4 7 1 I G H C B D E A 2 11 14 15 THERMO 2000 inc. DESSI N D'ATELI ER / GENERAL DI MENSI ONS COMBOMAX XX-XX Legeng/Légende: 1) Boiler Wat er Sup ply Co nnectio n / A limen.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 4. General Safety Precautions Be sure to read and understand the entire Us e & Care Manual before attempting to install or operate this water heater. Pay par ticular attention to the following General Safety Precautions.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 5. Section 3 : INSTALLATION The manufacturer’s w arranty does not cover any damage or defect caused by installati.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 6. Install shutoff (ball) valves for servicing convenience. Install thermometers on the inlet and outlet lines. Never plug the pressure relief valv e to avoid creating a hazardous situation.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 7. Pump flow rate = Boiler output ÷ BWTD ÷ 500 • Pump flow rate is expressed in U.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 8. cold water supply line between the COMBOMAX MC unit and flow check valve. Contact your installing contractor, water supplier, local plumbing inspector or plumbing supply house for assistance.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 9. 3.11 BI-ENERGY SETUP To take advantage of a special domestic electric utility rate, your COMBOMAX MC boiler can be combined with an existing oil or gas-fired furnace.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 10. Section 4 : Operation Before operating this w ater heater, be sure to read and follow these instructions, as well as the w arnings printed in this manual.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 11. Adjust the boiler aquastats as required. Please note that lowering the setting will not have an immediate effect as the heat stored in the boiler water must first be consumed.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 12. 4.6 ADJUSTING THE MIXING VALVE A thermostatically controlled mixing valve works automatically thanks to t he thermostatic element controlling the mix of very hot and cold water as required to provide safe domestic hot water under variable conditions.
THERMO 2OOO INC. 500 , 9 ième Avenue , C.P. 639, R ICHMOND ( Q UÉBEC) JOB 2HO T ÉL.: (819) 826-5613 F AX: (819) 826-6370 Section 5 : Maintenance Regular boiler maintenance will ensure trouble- free service for many years. It is recommended that you set up and follow a maintenance program.
COMBOMAX MC Electric boiler Set-up, use and care guide (revised January 2006) , Page 14. General Safety Precautions Be sure to read and understand the entire Use & Care Manual before attempting to install or operate this COMBOMAX MC unit. Pay particular attention to the following General Safety Precautions.
B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic h.
B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic h.
B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping E a u f r o i d e d o m e s t i q u e / D o m e s t i c c o l d w a t e r s up p l y Eau c.
L1 G C1 TH 1 TH 2 HL C1 Diagramme électrique/ Wiri n g dia gr am COMBOMAX 24 0 V Modèle/Model 6 - 10 K W Légende/ L egend TH C R HL Aquastat Élément chauffa n t/ Heating elemen t Contacteur de pu.
L1 G C1 TH 1 TH 2 Diagramme électrique/ Wiri n g dia gr am COMBOMAX 240V : modèle/ model 15 - 24 K W N C1 L2 C1 TH 3 TH 4 C1 Légende/ L egend TH C R HL Aquastat Élément chauffa n t/ Heating eleme.
L1 Diagramme électrique/ Wiri n g dia gr am Contrôle Bi-énergy/ Dual control ener g y CB E -E M N 120 Vac 24 Vac H H V3 V2 E1 E2 T1 T2 Bi-energie/ Dual ene r gy Electrique/ Ele ctr ic Mazout/ Oil R.
B AB A Tuyauteri e eau domestique/ Dom estic water pi ping Tuyauteri e eau de ch auffage/ Boiler water piping Eau froide dome stique / Domest ic co ld wate r su pply Eau chaude domestique/ Dom estic h.
Diagramme électrique/ Wiri n g dia gr am Raccordement de zone valves/ Wiring for zoned va lve s system Diagramme électrique/ Wiri n g dia gr am Raccordement de multiples circulateurs/ Wiring for m u.
Aquastat Priorité DHW/ DHW pr iori ty ( Sugg: 160F) Aquastat Élémen t no. 4/ Elemen t no. 4 ( Sugg: 165F) Aquastat Élémen t no. 3/ Elemen t no. 3 ( Sugg: 170F) Aquastat Élémen t no. 2/ Elemen t no. 2 ( Sugg: 175F) Aquastat Élémen t no. 1/ Elemen t no.
THERMO 2OOO INC. 500 , 9 ième Avenue , C.P. 639, R ICHMOND ( Q UÉBEC) JOB 2HO T ÉL.: (819) 826-5613 F AX: (819) 826-6370 COMBOMAX TM LIMITED WARRANTY Warranty Coverage for Residential Installatio n.
An important point after buying a device Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) you will learn all the available features of the product, as well as information on its operation. The information that you get Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) will certainly help you make a decision on the purchase.
If you already are a holder of Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ), but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ).
However, one of the most important roles played by the user manual is to help in solving problems with Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ). Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Thermo Products Models from 8 kW to 24 kW : 240 Volts ( single phase ) along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center