VLYNQ Port
User's Guide
September 2007

2 SPRU938B–September 2007 Submit Documentation Feedback


Read This First
This document describes the VLYNQ port in the TMS320DM643x Digital Media Processor (DMP).
The following documents describe the TMS320DM643x Digital Media Processor (DMP). Copies of these documents are available on the Internet at www.ti.com Tip: Enter the literature number in the search box provided at www.ti.com
The current documentation that describes the DM643x DMP, related peripherals, and other technical collateral, is available in the C6000 DSP product folder at: www.ti.com/c6000
SPRU978 — TMS320DM643x DMP DSP Subsystem Reference Guide. Describes the digital signal
processor (DSP) subsystem in the TMS320DM643x Digital Media Processor (DMP).
SPRU983 — TMS320DM643x DMP Peripherals Overview Reference Guide. Provides an overview and
briefly describes the peripherals available on the TMS320DM643x Digital Media Processor (DMP).
SPRAA84 — TMS320C64x to TMS320C64x+ CPU Migration Guide. Describes migrating from the
Texas Instruments TMS320C64x digital signal processor (DSP) to the TMS320C64x+ DSP. The objective of this document is to indicate differences between the two cores. Functionality in the devices that is identical is not included.
SPRU732 — TMS320C64x/C64x+ DSP CPU and Instruction Set Reference Guide. Describes the CPU
architecture, pipeline, instruction set, and interrupts for the TMS320C64x and TMS320C64x+ digital signal processors (DSPs) of the TMS320C6000 DSP family. The C64x/C64x+ DSP generation comprises fixed-point devices in the C6000 DSP platform. The C64x+ DSP is an enhancement of the C64x DSP with added functionality and an expanded instruction set.
signal processor (DSP) megamodule. Included is a discussion on the internal direct memory access (IDMA) controller, the interrupt controller, the power-down controller, memory protection, bandwidth management, and the memory and cache. Trademarks
VLYNQ is a trademark of Texas Instruments.
SPRU938B–September 2007 Preface 7 Submit Documentation Feedback

VLYNQ Port
1.1 Purpose of the Peripheral
The VLYNQ™communications interface port is a low pin count, high-speed, point-to-point serial interface in the TMS320DM643x Digital Media Processor (DMP) used for connecting to host processors and other VLYNQ compatible devices. The VLYNQ port is a full-duplex serial bus where transmit and receive operations occur separately and simultaneously without interference.
VLYNQ enables the extension of an internal bus segment to one or more external physical devices. The external devices are mapped to local physical address space and appear as if they are on the internal bus of the DM643x DMP. The external devices must also have a VLYNQ interface.
VLYNQ uses a simple block code (8b/10b) packet format and supports in-band flow control so that no extra terminals are needed to indicate that overflow conditions might occur.
The VLYNQ module on the DM643x DMP serializes a write transaction to the remote/external device and transfers the write via the VLYNQ port (TX pins). The remote VLYNQ module deserializes the transaction on the other side.
The read transactions to the remote/external device follow the same process, but the remote device's VLYNQ module serializes the read return data and transfers it to the VLYNQ port (RX pins). The read return data is finally deserialized and released to the device internal bus.
The external device can also initiate read and write transactions.

Figure 1 shows a functional block diagram of the VLYNQ port.
VLYNQ is an interface defined by Texas Instruments and does not conform to any other industry standard.
Introduction · INT55 interrupt controller

This section discusses the architecture and basic functions of the VLYNQ peripheral.
The module's serial clock direction and frequency are software configurable through the CLKDIR and CLKDIV bits in the VLYNQ control register (CTRL). The VLYNQ serial clock can be sourced from the internal system clock (CLKDIR = 1) or by an external clock source (CLKDIR = 0) for its serial operations.
The CLKDIV bit can divide the serial clock (1/1 - 1/8) down when the internal clock is selected as the source. The serial clock is not affected by the CLKDIV bit values, if the serial clock is externally sourced.
The reset value of the CLKDIR bit is 0 (external clock source).
The external clock source is shown in Figure 2. The internal clock source is shown in Figure 3.
VLYNQ CLKDIR=0
VLYNQ
VLYNQ_CLK
CLKDIR=0
Figure 3. Internal Clock Block Diagram
VLYNQ CLKDIR=1
VLYNQ CLKDIR=1
sys clk Don’t care

The VLYNQ module on the DM643x device supports 1 to 4 bit-wide RX/TX configurations. Chip-level pin multiplexing registers control the configuration. See the pin multiplexing information in the device-specific data manual.
If the VLYNQ data width does not match the number of transmit/receive lines that are available on the remote device, negotiation between the two VLYNQ devices automatically configures the width (see Section 2.7).
The VLYNQ interface signals are shown in Table 1.
Pin Name Signal Name Signal Type Function
VLYNQ_CLOCK VLYNQ serial clock Input/Output The VLYNQ reference clock supports the internally or externally generated clock.
VLYNQ_SCRUN VLYNQ serial clock run Input/Output The VLYNQ serial clock run request allows remote requests request (Active low) for the VLYNQ serial clock to be turned off for system power management. Low: The request VLYNQ serial clock is active. High: The VLYNQ serial clock is requested to be high when all transactions are complete.
VLYNQ_RXD[0:3] VLYNQ receive data Input VLYNQ receive data is synchronous with the VLYNQ serial clock.
VLYNQ_TXD[0:3] VLYNQ transmit data Output VLYNQ transmit data is synchronous with the VLYNQ serial clock.
Extensive use of pin multiplexing is used to accommodate the largest number of peripheral functions in the smallest possible package. Pin multiplexing is controlled using a combination of hardware configurations at device reset and software programmable register settings. The VLYNQ module pins are not enabled at reset. In order to change the default function of device pins at reset, the pin multiplexing registers (PINMUXn) must be configured appropriately. Refer to the pin multiplexing information in the device-specific data manual for more detailed information on the processor pin multiplexing and configuration registers.
VLYNQ relies on 8b/10b block coding to minimize the number of serial pins and allows for in-band packet delineation and control.
Appendix A provides general information on 8b/10b coding definitions and their implementation within the VLYNQ module in the DM643x device.

The VLYNQ core supports both host-to-peripheral and peer-to-peer communication models and is symmetrical. The VLYNQ module structure is shown in Figure 4.

The VLYNQ core module implements two 32-bit configuration bus interfaces. Transmit operations and control register access require the slave configuration bus interface. The master configuration bus interface is required for receive operations. Converting to and from the 32-bit bus to the external serial interface requires serializer and deserializer blocks.
8b/10b block coding encodes data on the serial interface. Frame delineation, initialization, and flow control use special overhead code groups.
FIFOs buffer the entire burst on the bus for maximum performance, thus minimizing bus latency. Using write operations of each VLYNQ module interfaced is typically recommended to ensure the best performance on both directions of the link.

Write requests that initiate from the slave configuration bus interface of the local device write to the outbound command (CMD) FIFO. Data is subsequently read from the FIFO and encapsulated in a write request packet. The address is translated, and the packet is encoded and serialized before being transmitted to remote device. The remote device subsequently deserializes and decodes the receive data and writes it into the inbound CMD FIFO. A write operation initiates on the remote device’s master configuration bus interface after reading the address and data from the FIFO.
The data flow between two VLYNQs that are connected is shown in Figure 5. In the example shown in Figure 5, the write originates from the DM643x device.


Read requests from the slave configuration bus interface are written to the outbound CMD FIFO (similar to the write requests). Data is subsequently read from the FIFO and encapsulated into a read request packet. The packet is encoded and serialized before it is transmitted to the remote device. Next, the remote device deserializes, decodes the receive data, and writes the receive data to the inbound CMD FIFO. After reading the address from the FIFO, a master configuration bus interface read operation initiates in the remote device. When the remote master configuration bus interface receives the read data, the data is written to the return data FIFO before it is encoded and serialized. When the receive data reaches the local VLYNQ module, it is deserialized, decoded, and written to the return data FIFO (local device). Finally, the read data is transferred on the local device’s slave configuration interface.
The data flow between two connected VLYNQ devices with read requests that originate from the DM643x device is shown in Figure 6. The remote VLYNQ device returns the read data. Read data is shown with dotted arrows.


Note: Not servicing read operations results in deadlock. The only way to recover from a deadlock situation is to perform a hard reset. Read operations are typically not serviced due to read requests that are issued to a non-existent remote VLYNQ device or they are not serviced due to trying to perform reads on the VLYNQ memory map prior to establishing the link.
Generally, you should not use read operations to transfer data packets since the serial nature of the interface could potentially result in longer latencies. See Appendix B for more information.
Since VLYNQ devices can be controlled solely over the serial interface (that is, no local CPU exists), an automatic reliable initialization sequence (without user configuration) establishes a connection between two VLYNQ devices, just after a VLYNQ module is enabled and auto-negotiation occurs. Auto-negotiation is defined in Section 2.7. The same sequence is used to recover from error conditions. However, it is important to ensure that the appropriate bits are configured in the pin mux registers to ensure that the VLYNQ peripheral is active.
Bit 0 in the VLYNQ status register (LINK bit) is set to 1 when a link is established.
A link pulse timer generates a periodic link code every 2048 serial clock cycles. The link is lost when time expires and no link code has been detected during a period of 4096 serial clock cycles.
Auto-negotiation occurs after reset. It involves placing a negotiation protocol in the outbound data and processing the inbound data to establish connection information. The width of the data pins on the serial interface is automatically determined at reset as a part of the initialization sequence. For a connection between two VLYNQ devices of version 2.0 and later (VLYNQ on DM643x device is version 2.6), the negotiation protocol using the available serial pins is used to convey the maximum width capability of each device. The TXD data pins are not required to have the same width as the RXD data pins.
The auto width negotiation does not occur until after completion of the VLYNQ 1.x legacy width configuration, which involves a period of 2000 VLYNQ 1.x system clock cycles for connection to VLYNQ 1.x devices. After the VLYNQ 1.x has determined its width, it receives the VLYNQ2.x auto width negotiation protocol. The VLYNQ 1.x device does not recognize this protocol and transmits error codes over the serial interface. The received error codes allow the VLYNQ 2.x devices to determine how many serial pins are valid on the connected VLYNQ 1.x device.
Once the width is established, VLYNQ further identifies the version (version 1.x or version 2.x ) of the remote VLYNQ. This better determines the capabilities of the connected VLYNQ device. This is software readable via the VLYNQ auto-negotiation register (AUTNGO), bit 16 (0 = Ver 1.x , 1 = Ver 2.x), after the link has been established.

Remote VLYNQ device(s) are memory mapped to the local (host) device’s address space when a link is established (this is similar to any other on-chip peripherals). Enumerating the VLYNQ devices (single or multiple) into a coherent memory map for accessing each device is part of the initialization sequence.
After the enumeration, the host (local) device can access the remote device address map using local device addresses. The VLYNQ module in the host device manages the address translation of the local address to the remote address. A remote VLYNQ device is mapped to the local device’s address via the address map registers (TX address map, RX address map size n, RX address map offset n, where n = 1 to 4). The transmit side has a contiguous map; the size of the map is the same as the remote device map. Figure 7 illustrates this mapping.
In the local device, the address of the VLYNQ remote memory map in the local configuration space is the transmit address accessing remote devices over the serial interface. The address of the VLYNQ remote memory map is programmed in the TX address map register (XAM). When the local device transmits, first it strips off the transmit address offset in the local device memory map. Then, the local device sends the data with an address offset from the transmit address.
VLYNQ allows each receive packet address to be translated into one of the four mapped regions. The size and offset of each memory region must be aligned to 32-bit words. No restriction is placed on programming the size or on the offset of each mapped region, as long as the total memory that is mapped into these one to four regions is not more then 64 MBytes.
Note: Care should be taken while programming the receive address map size register (RAMSn) and the receive address map offset register (RAMOn) values. These registers should be programmed with valid address locations and memory size to match the device specifications. See the Memory Map Summary and the System Interconnect sections in your device-specific data manual to identify the valid memory regions that can be accessed by an off-chip peer device through the VLYNQ interface.
The transmitted address is used to determine which remote mapped region is being accessed at the remote device. This is achieved by summing each memory size sequentially until the memory size is larger than the transmitted address. The last memory size that is added is the targeted region. A memory size and an offset specify the remote map. The remote map is programmed in the RX address map size register (RAMSn) and in the RX address map offset (RAMOn) in the remote device.

0000:0000h
0400:0000h (4C00:0000h on DM643x device)
03FF:FFFFh 0400:0000h
0800:0000h 07FF:FFFFh
0400:00FFh
0800:0100h 0800:00FFh
0500:0000h
0801:0100h 0801:00FFh
0500:FFFFh
0B00:0000h
0841:00FFh
0B3F:FFFFh
The following shows an example illustrating the address translation used in each VLYNQ module.
Address bits [31:26] are not used for address translation to remote devices on the DM643x device.
Table 2 shows the address map register configuration when the DM643x device is transmitting data to the remote device.
Register DM643x VLYNQ Module Remote VLYNQ Module
RX Address Map Size 1 Do not care 0000 : 0100h
RX Address Map Offset 1 Do not care 0800 : 0000h

subtract 0000 : 0000h TX address map register (there is no need to change the reset value of the DM643x device for this register)
The local address 4C00:0054h (or 0000 0054h) was translated to 0800:0054h on the remote VLYNQ device in Table 3.
Table 3 shows the address map register configuration when the DM643x device is receiving data from the remote device.
Register DM643x VLYNQ Module Remote VLYNQ Module
TX Address Map Do not care 0400 : 0000h
RX Address Map Size 1 0000 : 0100h Do not care
RX Address Map Offset 1 0200 : 0000h Do not care
RX Address Map Size 2 0000 : 0100h Do not care
RX Address Map Offset 2 8200 : 0000h Do not care
0000 : 0154h The RX packet address is greater than the value in the RX address map size 1 register
Since the RX packet address < the RX address map size 1 register + RX address map size 2 register

The remote address 0400:0154h (or 0000 0054h) was translated to 8200:0054h on the DM643x (local) device in this example.
The translated address for packets received on the serial interface is determined as follows:
If (RX Packet Address < RX Address Map Size 1 Register) {
Translated Address = RX Packet Address +
RX Address Map Offset 1 Register
} else if (RX Packet Address < (RX Address Map Size 1 Register +
RX Address Map Size 2 Register)) { Translated Address = RX Packet Address +
RX Address Map Offset 2 Register - RX Address Map Size 1 Register } else if (RX Packet Address < (RX Address Map Size 1 Register +
RX Address Map Size 2 Register + RX Address Map Size 3 Register)) { Translated Address = RX Packet Address +
RX Address Map Offset 3 Register -
RX Address Map Size 1 Register - RX Address Map Size 2 Register
} else if (RX Packet Address < (RX Address Map Size 1 Register +
RX Address Map Size 2 Register + RX Address Map Size 3 Register +
RX Address Map Size 4 Register)) { Translated Address = RX Packet Address +
RX Address Map Offset 4 Register -
RX Address Map Size 1 Register - RX Address Map Size 2 Register - RX Address Map Size 3 Register } else {
Translated Address = 0x0
The VLYNQ module includes flow control features. The VLYNQ module automatically generates flow control enable requests, /P/, when the RX/inbound FIFOs (FIFO1 and FIFO2) resources are consumed. The FIFOs can take up to 16 32-bit words.
The remote device will begin transmitting idles, /I/, starting on the first byte boundary following reception of the request. When sufficient RX FIFO resources have been made available, a flow control disable request, /C/, is transmitted to the remote device. In response, the remote device will resume transmission of data. See Appendix A.
}

2.10.1 Software Reset Considerations
Peripheral clock and reset control is done through the power and sleep controller (PSC) module that is included with the device. For more information, see Section 2.13. Additionally, there is a software reset (the reset bit in the VLYNQ control register, CTRL) within the peripheral itself. Writing a 1 to the reset bit resets all of the internal state machines of the VLYNQ module, the serial interface is disabled, and the link is lost. The VLYNQ module remains in reset until the software clears the bit.
When a hardware reset occurs, the VLYNQ peripheral resets its register values to the default values and the serial interface is disabled. After a hardware reset, the VLYNQ memory mapped registers and any chip-level registers that are associated with VLYNQ (for example, pin multiplexing registers) must be configured appropriately before data transmission can resume.
Be cautious when only resetting one of the VLYNQ devices after two or more VLYNQ devices have established a link. If only one of the VLYNQ devices is in reset, then no data activity can occur across the serial interface during the time of reset.
2.11.1 Interrupt Events and Requests
The VLYNQ module interrupt VLQINT is mapped to the interrupt controller (INT55). For more information on the interrupt controller, see the device-specific data manual.

For additional flexibility of interrupt handling, the INSTAT bit in the interrupt priority vector status/clear register (INTPRI) reports the highest priority interrupt asserted in INTPENDSET when INTLOCAL = 1 in CTRL. The VLYNQ interprets bit 0 of the INSTAT bits as the highest priority and interprets bit 31 as the lowest priority. The value that is returned when read is the vector of the highest priority interrupt. Software can clear that interrupt by writing back the vector value. Additionally, INTRPRI provides a read-only status bit (NOINTPEND) to indicate whether or not there are any pending interrupts in INTSTATCLR.
The VLYNQ interrupt generation mechanism is shown in Figure 8.
Serial interrupt packet from remote device
Serial bus error (LERROR/RERROR)
VLYNQ control register (CTRL)
VLYNQ interrupt pending/set register
INTLOCAL
INTLOCAL=1
INTLOCAL=0
OR
Transmit serial interrupt packet VLQINT
2.11.2 Writes to Interrupt Pending/Set Register
As previously discussed, if the CPU writes to the VLYNQ interrupt pending/set register (INTPENDSET), then depending on the value of the INTLOCAL bit in the VLYNQ control register (CTRL), this will result in a local interrupt (to the device interrupt controller) or an interrupt packet transmitted over the serial interface to the remote device.
CPU writes · VLYNQ Status/clear · register (INTSTATCLR)

Remote interrupts occur when an interrupt packet is received over the serial interface from a remote device. The interrupt status is extracted from the packet and written to a location pointed to by the interrupt pointer register (INTPTR).
The INTPTR should contain the address of the interrupt pending/set register (INTPENDSET). To get INTPTR to contain the address of INTPENDSET, program INTPTR with a value of 14h (the offset for INTPENDSET). Additionally, the INT2CFG bit in the VLYNQ control register (CTRL) must be set to 1, dictating that the VLYNQ writes to a local register space (in this case, INTPENDSET).
Once an interrupt packet is received over the serial interface, the interrupt status is extracted and written to INTPENDSET. After the interrupt status is extracted and written to INTPENDSET, the interrupt generation occurs as previously described in Section 2.11.2.
Due to erroneous transmit packets that are detected by remote devices (remote error) or errors in the inbound packets (local error), the serial bus errors result in the setting of the RERROR or LERROR bits in the VLYNQ status register (STAT).
Additionally, if the INTENABLE bit is set in the VLYNQ control register (CTRL), setting the RERROR or LERROR bits cause these status interrupts to post to the interrupt pending/set register (INTPENDSET), causing the VLYNQINT to be asserted to the CPU.
To ensure that serial bus errors result in interrupts to notify the application software, you must perform the following steps: 1. Set the INTENABLE bit to 1 in the VLYNQ control register (CTRL). 2. Set the INTVEC bits in CTRL to point to a free bit in the VLYNQ interrupt pending/set register (INTPENDSET). The serial bus error should result in setting the bits in INTPENDSET that are not used by the application software for other interrupts (bit locations written directly in INTPENDSET or via remote interrupts). 3. During VLYNQ initialization, the RERROR bit is set after the VLYNQ module achieves a link. When the link bit is set in the VLYNQ status register (STAT), write a 1 to the RERROR bit. Writing a 1 to the RERROR bit clears the RERROR bit and prevents the software interrupt handler from seeing the first RERROR as a legitimate serial bus error interrupt.
The VLYNQ module on the DM643x device is classified as a master peripheral. Classification as a master peripheral normally implies that the peripheral is able to sustain its own transfers without relying on any external peripherals (for example, the system DMA, etc). However, the VLYNQ module does not have an internal DMA (as some other master peripherals).
Therefore, it is likely that the VLYNQ module can rely on the on-chip enhanced DMA (EDMA3) controller for performing burst transfer. The EDMA3 can still be used to perform burst transfers out to remote VLYNQ memory map (writes). This use model provides better throughput with less overhead.
The VLYNQ module uses a 16-word deep FIFO to buffer the burst writes. Since the EDMA3 controller is much faster compared to the serial VLYNQ interface, a data back-up can occur. Therefore, configuring EDMA3 for optimal transfer size, etc. is essential.

The VLYNQ module can be placed in reduced-power modes to conserve power during periods of low activity. The power management of the VLYNQ module is controlled by the processor Power and Sleep Controller (PSC). The PSC acts as a master controller for power management for all of the peripherals on the device. For detailed information on power management procedures using the PSC, see the TMS320DM643x DMP DSP Subsystem Reference Guide (SPRU978).
If the serial clock is internally sourced, you can use the CLKDIV bit in the VLYNQ control register (CTRL) to divide the serial clock down. This saves normal mode operation power consumption (at the expense of reduced performance).
Additionally, the module provides the capability of auto-idling the serial clock domain (disable the VLYNQ CLK) when the serial clock is sourced from the DM643x device and the VLYNQ SCRUN pin is connected to the remote device. This allows power savings when there is no activity on the serial interface.
Note: There is no support for external wake-up for the VLYNQ module on the DM643x device. If the VLYNQ module on the DM643x device has been disabled via the PSC, then even though serial activity requests can be indicated from the remote VLYNQ device via the VLYNQ SCRUN pin, it does not allow the serial clock (VLYNQ CLK) to be sourced until the VLYNQ module is re-enabled via the PSC.
This can be configured by enabling the power management enable (PMEN) bit in the VLYNQ control registers (CTRL, 0 = disable, 1 = enable) . This bit should only be set if the SCRUN pin is connected to the remote VLYNQ device.
The SCRUN pin is a bi-directional pin which is driven low whenever there is serial activity on the local or remote VLYNQ interface.
There are no endianness considerations for the VLYNQ peripheral.
During debug, the CPU may be halted for single stepping, bench marking, profiling, or other debug uses using the emulator. VLYNQ does not support emulation halts/suspend operation. VLYNQ operations continue during emulation halt/suspend.

Table 4 describes the address space for the VLYNQ registers and memory.
Block Name Start Address End Address Size
VLYNQ Control Registers 01E0 1000h 01E0 11FFh 512 bytes
Reserved 01E0 1200h 01E0 1FFFh -
VLYNQ Remote Memory Map 4C00 0000h 4FFF FFFFh 64 Mbytes
Table 5 lists the memory-mapped registers for the VLYNQ port controller. See the device-specific data manual for the memory address of these registers.
The first 128 bytes map to the VLYNQ configuration registers that are maintained by the local (device) VLYNQ register control module while the second 128 bytes map to the remote configuration registers that are physically located in the remote device linked by the VLYNQ serial interface. Any access to the second set of registers causes VLYNQ to issue a read or write VLYNQ packet to be transmitted and only completes if a link is established between the two devices.
Offset Acronym Register Description Section
0h REVID Revision Register Section 3.1
4h CTRL Control Register Section 3.2
8h STAT Status Register Section 3.3
Ch INTPRI Interrupt Priority Vector Status/Clear Register Section 3.4
10h INTSTATCLR Interrupt Status/Clear Register Section 3.5
14h INTPENDSET Interrupt Pending/Set Register Section 3.6
18h INTPTR Interrupt Pointer Register Section 3.7
1Ch XAM Transmit Address Map Register Section 3.8
20h RAMS1 Receive Address Map Size 1 Register Section 3.9
24h RAMO1 Receive Address Map Offset 1 Register Section 3.10
28h RAMS2 Receive Address Map Size 2 Register Section 3.11
2Ch RAMO2 Receive Address Map Offset 2 Register Section 3.12
30h RAMS3 Receive Address Map Size 3 Register Section 3.13
34h RAMO3 Receive Address Map Offset 3 Register Section 3.14
38h RAMS4 Receive Address Map Size 4 Register Section 3.15
3Ch RAMO4 Receive Address Map Offset 4 Register Section 3.16
40h CHIPVER Chip Version Register Section 3.17
44h AUTNGO Auto Negotiation Register Section 3.18

The revision register (REVID) contains the major and minor revisions for the VLYNQ module. The REVID is shown in Figure 9 and described in Table 6.
ID
15 8 7 0
Bit Field Value Description
31-16 ID 01h Unique module ID.
15-8 REVMAJ 0-FFh Major revision.
2h Current major revision.
7-0 REVMIN 0-FFh Minor revision.
6h Current minor revision.
R-1h · R-2h R-6h

The control register (CTRL) determines operation of the VLYNQ module. The CTRL is shown in Figure 10 and described in Table 7.
31 30 29 27 26 24 23 22 21 20 19 18 16
PMEN SCLKPUDIS Reserved RXSAMPELVAL RTMVALIDWR RTMENABLE TXFASTPATH Reserved CLKDIV
R/W- 0 R/W- 0 R-0 R/W- 3h R/W- 0 R/W- 0 R/W- 0 R-0 R/W- 0
15 14 13 12 8 7 6 3 2 1 0
CLKDIR INTLOCAL INTENABLE INTVEC INT2CFG Reserved AOPTDISABLE ILOOP RESET
R/W- 0 R/W- 0 R/W- 0 R/W-0 R/W-0 R-0 R/W- 0 R/W- 0 R/W- 0
Bit Field Value Description
31 PMEN Power management enable.
0 VLYNQ CLK is always active if it is set as an output (assuming that VLYNQ module is enabled).
If set as an output, VLYNQ CLK becomes inactive when there is no traffic over the serial bus. 1 The PMEN bit should only be set to 1 when the SCRUN is connected to the remote/external VLYNQ device.
30 SCLKPUDIS 0 Serial clock pull-up disable. Always write 0.
29-27 Reserved 0 Reserved. Always read as 0. Writes have no effect.
26-24 RXSAMPELVAL 0-7h RTM sample value. If the RTMENABLE bit is 0, the receive timing manager forces the value in the RXSAMPELVAL bit as the clock sample value. If the RTMENABLE bit is 1, then the value set by the RXSAMPELVAL bit is ignored. In order to modify the value, you must simultaneously write a 1 to the RTMVALIDWR bit.
23 RTMVALIDWR RTM valid write bit.
0 Will not allow writes to RXSAMPLEVAL bits.
1 Will allow writes to RXSAMPLEVAL bits.
22 RTMENABLE RTM enable bit.
The receive timing manager uses the value set in the RXSAMPLEVAL bit as the clock sample 0 value.
1 The receive timing manager is enabled. It automatically selects the receive clock.
21 TXFASTPATH 0-1 Transmit fast path. When set, the fastest path is chosen for the serial data.
20-19 Reserved 0 Reserved. Always read as 0. Writes have no effect.
18-16 CLKDIV 0-7h Serial clock output divider.
15 CLKDIR Serial CLK direction. Determines whether the VLYNQ CLK is an input or an output.
0 The VLYNQ CLK is externally sourced.
The VLYNQ CLK is internally sourced and equal to the VLYNQ module system clock divided by the 1 divider value set in the CLKDIV bit.
14 INTLOCAL Interrupt local.
0 The interrupt is forwarded to the remote VLYNQ device over the serial interface as an interrupt packet.
Interrupt is posted in the interrupt status/clear register and results in the assertion of the VLQINT to 1 the device interrupt controllers.
13 INTENABLE Interrupt enable.
0 VLYNQ module status interrupts are ignored.
VLYNQ module status interrupts (if RERROR or LERROR bits are set) are posted to the interrupt 1 pending/set register.
12-8 INTVEC 0-1Fh Interrupt vector. This bit indicates which bit in the interrupt pending/set register is set for VLYNQ module status (RERROR/LERROR) interrupts.

Bit Field Value Description
7 INT2CFG Interrupt to configuration register. Determines which register is written with the status contained in interrupt packets that are received over the serial interface. Always write 1 to this bit and configure the interrupt pointer register to point to the interrupt pending/set register.
0 Bits[31:2] of the interrupt pointer register are used to point to a system interrupt register.
1 The least significant 8 bits of the interrupt pointer register are used to point to a VLYNQ module local register (typically the interrupt pending/set register).
6-3 Reserved 0 Reserved. Always read as 0. Writes have no effect.
2 AOPTDISABLE Address optimization disable.
0 Address optimization is enabled, eliminating unnecessary address bytes.
1 Address optimization is disabled.
1 ILOOP Internal loop back.
0 Normal operation.
1 Serial transmit data is wrapped back to the serial receive data.
0 RESET Software reset. It does not reset the VLYNQ memory-mapped registers (except for the VLYNQ status register). You have to reprogram the VLYNQ registers if they must have a different value after a software reset.
0 Normal operation.
1 All internal state machines are reset, the serial interface is disabled, and the link is lost.

The status register (STAT) is used to detect conditions that may be of interest to the system designer. The STAT is shown in Figure 11 and described in Table 8.
31 28 27 24 23 20 19 15
Reserved SWIDTHIN SWIDTHOUT Reserved
14 12 11 10 9 8
R-0 R-1 R-0 R-0 W1C-0
7 6 5 4 3 2 1 0
W1C-0 R-0 R-0 R-0 R-0 R-0 R-0 R-0
LEGEND: R/W = Read/Write; R = Read only; W1C = Write 1 to clear bit; -n = value after reset; x= reset value is indeterminate
Bit Field Value Description
31-28 Reserved 0 Reserved. Always read as 0. Writes have no effect.
27-24 SWIDTHIN Size of the inbound serial data. Indicates the number of receive pins that are being used to 0-Fh establish the serial interface.
0 No pins used
1h 1 RX pin used
2h 2 RX pins used
3h 3 RX pins used
4h 4 RX pins used
23-20 SWIDTHOUT 0-Fh Size of the outbound serial data. Indicates the number of transmit pins that are being used to establish the serial interface.
0 No pins used
1h 1 TX pin used
2h 2 TX pins used
3h 3 TX pins used
4h 4 TX pins used
19-15 Reserved 0 Reserved. Always read as 0. Writes have no effect.
14-12 RXCURRENTSAMPLE 0-Fh Current RTM sample. Indicates the current clock sample value used by RTM.
11 RTM 1 RTM enable. Always read as 1. Indicates that the VLYNQ module on the DM643x DMSoC has the receive timing manager (RTM).
10 IFLOW Inbound flow control.
0 Free to transmit.
Indicates that a flow control enable request has been received and has stalled transmit until 1 a flow control disable request is received.
9 OFLOW Outbound flow control. Indicates the status of the two inbound FIFOs (FIFO1 or FIFO2).
0 Indicates that the internal flow control threshold is not yet reached.
Indicates that the internal flow control threshold has been reached (FIFO1 or FIFO2 is full) 1 and a flow control enable request has been sent to the remote device.
5h-Fh Reserved · 5h-Fh Reserved

Bit Field Value Description
8 RERROR Remote Error. Write a 1 to this bit to clear it.
This bit indicates that a downstream VLYNQ module has detected a packet error. This bit is 1 set when an error indication, /E/, is received from the serial interface. See Appendix A.
If this bit is set, and the INTENABLE (bit 13 in VLYNQ control register) is also set, it asserts the VLYNQ interrupt (VLQINT).
7 LERROR Local error. Write a 1 to this bit to clear it.
0 No error.
This bit indicates that an inbound packet contains an error that is detected by the local 1 VLYNQ module.
If this bit is set, and the INTENABLE (bit 13 in VLYNQ control register) is also set, it asserts the VLYNQ interrupt (VLQINT).
6 NFEMPTY3 FIFO 3 is not empty.
0 Indicates that the slave command FIFO is empty.
1 Indicates that the slave command FIFO is not empty.
5 NFEMPTY2 FIFO 2 is not empty.
0 Indicates that the slave data FIFO is empty.
1 Indicates that the slave data FIFO is not empty.
4 NFEMPTY1 FIFO 1 is not empty.
0 Indicates that the master command FIFO is empty.
1 Indicates that the master command FIFO is not empty.
3 NFEMPTY0 FIFO 0 is not empty.
0 Indicates that the master data FIFO is empty.
1 Indicates that the master data FIFO is not empty.
2 SPEND Pending slave request.
0 No pending slave requests.
Indicates detection of a transfer request initiated by the VLYNQ module to the off-chip 1 peripheral (TX slave configuration bus interface).
1 MPEND Pending master requests.
0 No pending master requests.
Indicates detection of a transfer request initiated by an off-chip peripheral to the VLYNQ 1 module (RX master configuration bus interface).
0 Indicates that the serial interface initialization sequence has not yet completed or the link has timed out.
1 Indicates that the serial interface initialization sequence has completed successfully.
0 No error · 0 LINK Link

The interrupt priority vector status/clear register (INTPRI) displays the highest priority vector with a pending interrupt when read. When writing, only bits [4:0] are valid, and the value represents the vector of the interrupt to be cleared. The INTPRI is shown in Figure 12 and described in Table 9.
15 5 4 0
Bit Field Value Description
31 NOINTPEND Interrupt pending status.
0 Indicates there is a pending interrupt.
1 Indicates that there are no pending interrupts from the interrupt status/clear register.
30-5 Reserved 0 Reserved. Always read as 0. Writes have no effect.
4-0 INSTAT 0-1Fh When read, this field displays the vector that is mapped to the highest priority interrupt bit that is pending from the interrupt status/clear register (INSTATCLR), with bit 0 as the highest priority, and bit 31 as the lowest. Writing the vector value back to this field clears the interrupt.
The interrupt status/clear register (INTSTATCLR) indicates the unmasked interrupt status. The INTSTATCLR is shown in Figure 13 and described in Table 10.
INTCLR
R/W-0
Bit Field Value Description
31-0 INTCLR 0-FFFF FFFFh This field indicates the unmasked status of each interrupt. Writing a 1 to any set bit in this field clears the corresponding interrupt. If there is a bit set in this register and if the INTLOCAL bit in the control register (CTRL) is also set, the VLYNQ interrupt (VLQINT) is asserted.

The interrupt pending/set register (INTPENDSET) indicates the pending interrupt status when the INTLOCAL bit in the control register (CTRL) is not set. When the interrupt packet is forwarded on the serial interface, these bits are cleared. The INTPENDSET is shown in Figure 14 and described in Table 11.
INTSET
R/W-0
Bit Field Value Description
31-0 INTSET 0-FFFF FFFFh This field indicates the unmasked status of each pending interrupt.
0 Writing a 0 has no effect.
1 Writing a 1 to any bit:
if INTLOCAL = 0 in CTRL, interrupt packet is sent on the serial interface.
If INTLOCAL = 1 in CTRL, VLYNQ module interrupt (VLQINT) is asserted.
The interrupt pointer register (INTPTR) typically contains the address of the interrupt pending/set register (INTPENDSET) within the VLYNQ module. To program INTPTR to point to INTPENDSET, program a value of 14h (the offset of INTPENDSET). Additionally, the INT2CFG bit in the control register (CTRL) should be set to 1. The INTPTR is shown in Figure 15 and described in Table 12.
31 2 1 0
Bit Field Value Description
31-2 INTPTR 0-3FFF FFFFh Interrupt pointer. Program this register with the address (14h) of the interrupt pending/set register (INTPENDSET).
1-0 Reserved 0 Reserved. Always read as 0. Writes have no effect.
INTPTR Reserved

The transmit address map register (XAM) is used to translate transmit packet addresses to remote device configuration bus addresses. The XAM is shown in Figure 16 and described in Table 13.
31 2 1 0
Bit Field Value Description
31-2 TXADRMAP 0-3FFF FFFFh This field is subtracted from the slave configuration bus address [25:0] to obtain the zero relative transmit packet address. This field should be programmed with a value of 0 (reset value).
1-0 Reserved 0 Reserved. Always read as 0. Writes have no effect.
TXADRMAP Reserved

The receive address map size 1 register (RAMS1) is used to identify the intended destination of inbound serial packets. The RAMS1 is shown in Figure 17 and described in Table 14.
31 2 1 0
Bit Field Value Description
31-2 RXADRSIZE1 0-3FFF FFFFh The RXADRSIZE1 field is used to determine if receive packets are destined for the first of four mapped address regions. RXADRSIZE1 is compared with the address contained in the receive packet. If the received packet address is less than the value in RXADRSIZE1, the packet address is added to the receive address map offset 1 register (RAMO1) to obtain the translated address.
1-0 Reserved 0 Reserved. Always read as 0. Writes have no effect.
The receive address map offset 1 register (RAMO1) is used with the receive address map size 1 register (RAMS1) to translate receive packet addresses to local device configuration bus addresses. The RAMO1 is shown in Figure 18 and described in Table 15.
31 2 1 0
Bit Field Value Description
31-2 RXADROFFSET1 0-3FFF FFFFh The RXADROFFSET1 field is used with the receive address map size 1 register (RAMS1) to determine the translated address for serial data. If the received packet address is less than the value in RAMS1, the packet address is added to the contents of this register to obtain the translated address.
1-0 Reserved 0 Reserved. Always read as 0. Writes have no effect.
RXADRSIZE1 Reserved · RXADROFFSET1 Reserved

The receive address map size 2 register (RAMS2) is used to identify the intended destination of inbound serial packets. The RAMS2 is shown in Figure 19 and described in Table 16.
31 2 1 0
Bit Field Value Description
31-2 RXADRSIZE2 0-3FFF FFFFh The RXADRSIZE2 field is used to determine if receive packets are destined for the second of four mapped address regions. RXADRSIZE2 is compared with the address contained in the receive packet. If the received packet address is less than the value in RXADRSIZE2, the packet address is added to the receive address map offset 2 register (RAMO2) to obtain the translated address.
1-0 Reserved 0 Reserved. Always read as 0. Writes have no effect.
The receive address map offset 2 register (RAMO2) is used with the receive address map size 2 register (RAMS2) to translate receive packet addresses to local device configuration bus addresses. The RAMO2 is shown in Figure 20 and described in Table 17.
31 2 1 0
Bit Field Value Description
31-2 RXADROFFSET2 0-3FFF FFFFh The RXADROFFSET2 field is used with the receive address map size 2 register (RAMS2) to determine the translated address for serial data. If the received packet address is less than the value in RAMS2, the packet address is added to the contents of this register to obtain the translated address.
1-0 Reserved 0 Reserved. Always read as 0. Writes have no affect.
RXADRSIZE2 Reserved · RXADROFFSET2 Reserved

The receive address map size 3 register (RAMS3) is used to identify the intended destination of inbound serial packets. The RAMS3 is shown in Figure 21 and described in Table 18.
31 2 1 0
Bit Field Value Description
31-2 RXADRSIZE3 0-3FFF FFFFh The RXADRSIZE3 field is used to determine if receive packets are destined for the third of four mapped address regions. RXADRSIZE3 is compared with the address contained in the receive packet. If the receive packet address is less than the value in RXADRSIZE3, the packet address is added to the receive address map offset 3 register (RAMO3) to obtain the translated address.
1-0 Reserved 0 Reserved. Always read as 0. Writes have no effect.
The receive address map offset 3 register (RAMO3) is used with the receive address map size 3 register (RAMS3) to translate receive packet addresses to local device configuration bus addresses. The RAMO3 is shown in Figure 22 and described in Table 19.
31 2 1 0
Bit Field Value Description
31-2 RXADROFFSET3 0-3FFF FFFFh The RXADROFFSET3 field is used with the receive address map size 3 register (RAMS3) to determine the translated address for serial data. If the receive packet address is less than the value in RAMS3, the packet address is added to the contents of this register to obtain the translated address.
1-0 Reserved 0 Reserved. Always read as 0. Writes have no effect.
RXADRSIZE3 Reserved · RXADROFFSET3 Reserved

The receive address map size 4 register (RAMS4) is used to identify the intended destination of inbound serial packets. The RAMS4 is shown in Figure 23 and described in Table 20.
31 2 1 0
Bit Field Value Description
31-2 RXADRSIZE4 0-3FFF FFFFh The RXADRSIZE4 field is used to determine if receive packets are destined for the fourth of four mapped address regions. RXADRSIZE4 is compared with the address contained in the receive packet. If the receive packet address is less than the value in RXADRSIZE4, the packet address is added to the receive address map offset 4 register (RAMO4) to obtain the translated address.
1-0 Reserved 0 Reserved. Always read as 0. Writes have no effect.
The receive address map offset 4 register (RAMO4) is used with the receive address map size 4 register (RAMS4) to translate receive packet addresses to local device configuration bus addresses. The RAMS4 is shown in Figure 24 and described in Table 21.
31 2 1 0
Bit Field Value Description
31-2 RXADROFFSET4 0-3FFF FFFFh The RXADROFFSET4 field is used with the receive address map size 4 register (RAMS4) to determine the translated address for serial data. If the receive packet address is less than the value in RAMS4, the packet address is added to the contents of this register to obtain the translated address.
1-0 Reserved 0 Reserved. Always read as 0. Writes have no effect.
RXADRSIZE4 Reserved · RXADROFFSET4 Reserved

VLYNQ allows inter-connection of many VLYNQ devices. In order for software to control the device functions, there must be a mechanism that allows the software to identify VLYNQ devices. Each device that has a VLYNQ module in it has a unique device ID associated with it, which is software readable via a memory-mapped register within the VLYNQ module called the chip version register (CHIPVER). This is also useful in communicating with remote devices, as the local VLYNQ device register map contains a copy of the remote device's registers as well. This allows the software to determine the remote chip ID and, hence, determine the remote memory-map without trying to access random remote addresses to find a device ID register. The CHIPVER is shown in Figure 25 and described in Table 22.
DEVREV
R-0
DEVID

31-16 DEVREV 0-FFFFh Device revision. This field reflects the value of the device revision pins.
The auto negotiation register (AUTNGO) reflects the ability of the VLYNQ module residing in the device to communicate with the remote VLYNQ device on their respective abilities after reset. The AUTNGO is shown in Figure 26 and described in Table 23.
R-0 R-0
R-0

31-17 Reserved 0 Reserved. Always read as 0. Writes have no effect.
0 Indicates that a link was established with a remote device that has a version 1.x VLYNQ module in it.
1 Indicates that a link was established with a remote device that has a version 2.x VLYNQ module in it.
15-0 Reserved 0 Reserved. Always read as 0. Writes have no effect.

The remote configuration registers listed in Table 24 are the same registers as previously described, but they are for the remote VLYNQ device.
It is not necessary to configure the address translation registers to access the remote device's memory-mapped registers after the link has been established.
Depending on the version and chip specific implementation, the VLYNQ module on the remote device might have additional registers or different reset values. Refer to the remote device data sheet for a precise description of the VLYNQ registers that exist in the remote device.
Offset Acronym Register Description
80h RREVID Remote Revision Register
84h RCTRL Remote Control Register
88h RSTAT Remote Status Register
8Ch RINTPRI Remote Interrupt Priority Vector Status/Clear Register
90h RINTSTATCLR Remote Interrupt Status/Clear Register
94h RINTPENDSET Remote Interrupt Pending/Set Register
98h RINTPTR Remote Interrupt Pointer Register
9Ch RXAM Remote Transmit Address Map Register
A0h RRAMS1 Remote Receive Address Map Size 1 Register
A4h RRAMO1 Remote Receive Address Map Offset 1 Register
A8h RRAMS2 Remote Receive Address Map Size 2 Register
ACh RRAMO2 Remote Receive Address Map Offset 2 Register
B0h RRAMS3 Remote Receive Address Map Size 3 Register
B4h RRAMO3 Remote Receive Address Map Offset 3 Register
B8h RRAMS4 Remote Receive Address Map Size 4 Register
BCh RRAMO4 Remote Receive Address Map Offset 4 Register
C0h RCHIPVER Remote Chip Version Register
C4h RAUTNGO Remote Auto Negotiation Register
C8h RMANNGO Remote Manual Negotiation Register
CCh RNGOSTAT Remote Negotiation Status Register
E0h RINTVEC0 Remote Interrupt Vector 3-0 Register
E4h RINTVEC1 Remote Interrupt Vector 7-4 Register
Remote Configuration Registers

A.1 Introduction
VLYNQ relies on 8b/10b block coding to minimize the number of serial pins and allow for in-band packet delineation and control. The following sections include general 8b/10b coding definitions and their implementation.
Table A-1. Special 8b/10b Code Groups
Code Group Name Octet Value Octet Bits Current RD - Current RD +
K28.1 3C 0011 1100 001111 1001 110000 0110
K28.2 5C 0101 1100 001111 0101 110000 1010
K28.3 7C 0111 1100 001111 0011 110000 1100
K28.4 9C 1001 1100 001111 0010 110000 1101
K28.5 BC 1011 1100 001111 1010 110000 0101
K28.6 DC 1101 1100 001111 0110 110000 1001
K28.7 FC 1111 1100 001111 1000 110000 0111
K23.7 F7 1111 0111 111010 1000 000101 0111
K27.7 FB 1111 1011 110110 1000 001001 0111
K29.7 FD 1111 1101 101110 1000 010001 0111
K30.7 FE 1111 1110 011110 1000 100001 0111
A.3 Supported Ordered Sets
Each VLYNQ module must support a limited number of ordered sets. Ordered sets provide for the delineation of packets and synchronization between VLYNQ modules at opposite ends of the serial connection. VLYNQ 2.0 and later versions do not require some of the following ordered sets.
Code Ordered Set Encoding Octet Value
/I/ Idle /K28.5/ BC
/T/ End of Packet /K29.7/ FD
/M/ Byte Disable /K23.7/ F7
/P/ Flow Control Enable /K28.0/ IC
/C/ Flow Control Disable /K28.2/ 5C
/E/ Error Indication /K28.1/ 3C
/0/ Init0 /K28.4/ 9C
/I/ Init1 /K28.6/ DC
/L/ Link /K30.7/ FE
SPRU938B–September 2007 VLYNQ Protocol Specifications 39 Submit Documentation Feedback
Appendix A

VLYNQ 2.0 Packet Format
The idle ordered sets are transmitted continuously and repetitively whenever the serial interface is idle. Idle is also used in the place of the flowed code in VLYNQ versions 2.0 and later.
An end of packet delimiter delineates the ending boundary of a packet.
The byte disable symbol masks bytes for write operations.
A flow control enable request is transmitted when a VLYNQ module’s receive FIFO is full or nearly full. This code causes the remote VLYNQ device to cease transmission of data.
The flow control disable request is transmitted by a VLYNQ module when RX FIFO resources are available to accommodate additional data.
The error indication is transmitted when errors are detected within a packet. Examples of such errors include illegal packet types and code groups.
The Init0 code group is used during the link initialization sequence. VLYNQ 2.0 and later versions use this code with an extra byte for identifying version 1.X devices.
The Init1code group is used during the Link initialization sequence. VLYNQ 2.0 and later uses this code with an extra byte for identifying version 1.X devices.
The link code group is used during the link initialization sequence. A link code group is also transmitted each time the internal link timer expires.
The VLYNQ 2.0 packet format is shown in Figure A-1 and described in Table A-3, where 0 < N < 65. Multi-byte fields are transferred least-significant byte first.
VLYNQ Protocol Specifications 40 SPRU938B–September 2007 Submit Documentation Feedback

VLYNQ 2.0 Packet Format
PKTTYPE[3:0] This field indicates the packet type.
0001 Write with address increment.
0011 Write 32-bit word with address increment.
0101 Configuration write with address increment.
0110 Reserved for extended command indicator (cmd2)
1001 Read with address increment.
1011 Read 32-bit word with address increment.
1101 Configuration read with address increment.
1110 Reserved for VLYNQ version 2.0 and later.
1111 Read response for all VLYNQ versions.
ADRMASK[3:0] Indicates which byte of the address is included in the packet. Only address bytes that have changed since the previous address will be included. Each bit corresponds to one byte of address.
BYTECNT[7:0] Byte count. This field indicates the total number of bytes in the packet. This field is only included for write, read, and configuration packet types. All other packet types have fixed lengths and do not require this field.
ADDRESS[7:0] Address byte 0. This byte is included only if ADRMASK[0] is set to 1. If ADRMASK[0] is cleared to 0, assume this byte is equal to bits 7:0 of the previous address. Read response packets do not include this field.
ADDRESS[15:8] Address byte 1. This byte is included only if ADRMASK[1] is set to 1. If ADRMASK[1] is cleared to 0, assume this byte is equal to bits 15:8 of the previous address. Read response packets do not include this field.
ADDRESS[23:16] Address byte 2. This byte is only included if ADRMASK[2] is set to 1. If ADRMASK[2] is cleared to 0, this assume this byte is equal to bits 23:16 of the previous address. Read response packets do not include this field.
ADDRESS[31:24] Address byte 3. This byte is only included if ADRMASK[3] is set to 1. If ADRMASK[3] is cleared to 0, assume this byte is equal to bits 31:24 of the previous address. Read response packets do not include this field.
DATA Data payload. The maximum data payload size is limited to sixteen 32-bit words to allow it to fit in the RX FIFO.
EOP End of packet indicator, /T/.
The CMD2 bit is only included in the packet, if the packet type indicates extended command (PKTTYPE = 0110).
Use configuration packet types to remotely access VLYNQ module registers. The configuration packet types do not depend on control register bit settings.
SPRU938B–September 2007 VLYNQ Protocol Specifications 41 Submit Documentation Feedback

VLYNQ 2.X Packets
An example of what can happen to a write burst due to remote and local FIFO state changes and the link pulse timer expiring is shown in Example A-1. This protocol can be extended to apply to multiple channels; therefore, the data return channel is logically isolated from the command channel.
Example A-1. A write burst due to remote and local FIFO state changes and the link pulse timer expiring
WriteCfg - claaaaddddddddT
WriteBurst - claaaaddddddddddddT
ReadReturn - clddddddddT Where I - Idle
M - Byte mask I[#] - Flowed, # is used when exiting flowed for a channel, the # is actually the current channel command. P# - Flow Enable for a channel
C# - Flow Disable for a channel L - Link pulse and what is in italics is optional data up to 16 words total. Packet with byte enables: WriteBurst - claaaaMMddMMddMMddT The above packet wrote to the LS half words from the specified address. Packet that has been flowed due to remote FIFO status: WriteBurst - claaaaMMddMIIIIIIIIIIIII#MddMMddT The packet was extended using the I code. The # is used to indicate that the same channel was continued. To the same packet, the potential flowing of the local FIFO’s is added: WriteBurst - claaaaMMddMIIP#IIIIIIIIIIIII#MddMMdC#dT Link pulse to the stream is added:
WriteBurst - claaLaaMMddMIIP#IIIIIIIIIII#MddMMdC#dT
An example of a write burst flowed and interrupted by a read return data burst is shown below. In the example, a 1 indicates a data return channel (it is actually the return data command) and a 0 indicates a command channel, which is the command for the transaction.
IIIIclaaaaddddIcldddIII1ddddII0dddddddddddddIIIIII0dddTIIIII1dTIIII
42 VLYNQ Protocol Specifications SPRU938B–September 2007 Submit Documentation Feedback

VLYNQ 2.X Packets
A command, length, address, and start receive data from the idle stream. A flow enable was received for the command channel, but there is data to return, so the flow is followed by a channel 1 descriptor (the command for return data actually indicates a channel 1), and the channel 1 packet is now under way. A flow is now received for channel 1, but it is soon disabled so the channel 1 packet continues. The flow is enabled for channel one again, quickly after flow is released for channel 0, so the data continues for channel 0 when a flow is received again for channel 0. Channel 0 then receives a flow disable, completes its packet, followed by channel 1 flow disable, where the channel 1 packet is also completed.
SPRU938B–September 2007 VLYNQ Protocol Specifications 43 Submit Documentation Feedback

B.1 Introduction
The following sections discuss the write versus read performance and how the throughput (read or write) should be calculated for a given data width and serial clock frequency.
Note: The data and throughput calculations shown here are sample calculations for most ideal situations. In general, the data rates depend on a variety of other factors, such as efficiency of read/write burst transactions, ability of buffering up read/write data, and how best it can be serially shifted out without stalling additional read/write data burst, remote and local components , both external and internal (device operations, board considerations, etc.).
The max write rate describes the maximum available data rate of the serial interface for transmission, taking into consideration the 8b/10b encoding overheads. This is calculated as follows:
Max write rate = VLYNQ Serial Clock (MHZ) × No. of Pins × 8b/10b encoding overhead
The 8b/10b encoding overhead essentially accounts for 20% overhead, thus the actual data throughput after subtraction of the encoding overhead gives a factor of 0.8. For example, if the VLYNQ clock is running at 99 MHZ on a 4 pin per direction interface, the raw data is 99 × 4 or 396 Mbps. After the 8B10B encoding is removed, the maximum write rate is 396 × 0.8 = 316.8 Mbps.
The total throughput on the VLYNQ interface includes both transmit and receive directions. Therefore, for the above configuration, a remote device can also be writing to the local device at the same data rates, then the total throughput is the sum of transmit and receive rates, or 633.6 Mbps.
In addition to the 8b/10b encoding, the packet structure for read/write operations also results in additional overheads. The VLYNQ module can transfer single 32-bit words or a burst of up to sixteen 32-bit words.
The packet structure of the writes is shown below, here each character represents a byte.
WriteBurst - claaaaddddddddddddT Where
d - data, dddd represents additional 32-bit words in burst, up to 16 words.
The example above illustrates that single writes require 6 bytes of overhead, while burst writes require 8 bytes of overhead (due to the additional length of the field). From this, a scaling factor can be calculated (data bytes/total bytes), as show in Table B-1. The actual throughput is then calculated as the [scaling factor] × [max write rate].
Table B-2 compares the throughput using a VLYNQ interface running at 76.5 MHZ and 99 MHZ.
Write/Read Performance 44 SPRU938B–September 2007 Submit Documentation Feedback

Burst Size in 32-bit words Data Bytes Overhead Bytes Scaling Factor
1 4 6 40%
4 16 7 69.56%
8 32 7 82.05%
16 64 7 90.14%
Table B-2. Expected Throughput (VLYNQ Interface Running at 76.5 MHZ and 99 MHZ)
Interface Running at 76.5 MHZ Interface Running at 99 MHZ Burst Size in Number of VLYNQ Pins 32-bit Words Mbits/sec Mbytes/sec Mbits/sec Mbytes/sec
1 1 24.19 3.02 31.68 3.96
4 42.07 5.26 55.09 6.89
8 49.62 6.20 64.98 8.12
16 54.52 6.81 71.39 8.92
2 1 48.38 6.05 63.36 7.92
4 84.14 10.52 110.18 13.77
8 99.25 12.41 129.97 16.25
16 109.03 13.63 142.78 17.85
3 1 72.58 9.07 95.04 11.88
4 126.21 15.78 165.27 20.66
8 148.87 18.61 194.95 24.37
16 163.55 20.44 214.17 26.77
4 1 96.77 12.10 126.72 15.84
4 168.28 21.03 220.37 27.55
8 198.50 24.81 259.93 32.49
16 218.07 27.26 285.56 35.70
SPRU938B–September 2007 Write/Read Performance 45 Submit Documentation Feedback
Write Performance

Since reads must complete a transmit-remote read-receive cycle before starting another read transaction, the data throughput is lower as compared to writes. There is latency involved in reading the data from the remote device; and in some cases, a local latency in writing the returned data before the next read can start.
The max read rate is calculated the same way as the max write rate. The packet overhead is as shown below:
ReadReturn - clddddddddT Where
d - data, dddd represents additional 32-bit words in burst, up to 16 words.
There are 6 bytes of overhead for a single read, 7 bytes for burst reads, and 3 bytes for read returns. The time required for a read is the total of the time for the read request, remote latency, read return, and local latency. Thus, the throughput can be calculated as data bytes/total transaction time, where the latency of both local and remote devices is combined.
Read Throughput = data/ (((Read + ReadReturn + data)/max read rate) + Latency
= (data × max read rate)/((Read + ReadReturn + data) + Latency × max
For example, with a 4 pin, 99 MHZ VLYNQ connection, for a single 32-bit word read:
Read Throughput = 32 bits × 316.8 Mbps/ (6 × 8 + 3 × 8 + 4 × 8 + Latency × 316.8Mbps)
= 10137.6/(104 + Latency × 316.8 Mbps)
Similarly, for a burst read of sixteen 32-bit words, with a 4 pin, 99 MHZ VLYNQ connection
Read Throughput = 16 × 32 bits × 316.8Mbps/(6 × 8 + 3 × 8 + 16 × 4 × 8 + Latency × 316.8Mbps)
= 162201.6/(584 + Latency × 316.8Mbps)
Using the formula above, the relative performance with various latencies is illustrated for a 4 pin, 99 MHZ VLYNQ clock, burst read (sixteen 32-bit words) throughput rate, as shown in Table B-3.
Throughput Number of VLYNQ Burst Size in Pins (99 MHZ) 32-bit Words Latency (μsec) Mbits/sec Mbytes/sec
4 16 0 277.74 34.72
1 179.70 22.46
10 43.02 5.38
100 5.00 0.62
To efficiently use VLYNQ bandwidth, it is desirable for each VLYNQ device to write from the local device to the remote device. Burst transactions are more efficient than single read/write transactions.
46 Write/Read Performance SPRU938B–September 2007 Submit Documentation Feedback

Table C-1 lists the changes made since the previous version of this document.
Section 2.8 Changed fourth paragraph.
Added NOTE.
Section 3.17 Changed paragraph.
Figure 25 Changed DEVID reset value.
Table 22 Changed DEVID Description.
SPRU938B–September 2007 Revision History 47 Submit Documentation Feedback
Appendix C · Reference Additions/Modifications/Deletions

Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Amplifiers amplifier.ti.com Audio www.ti.com/audio
Data Converters dataconverter.ti.com Automotive www.ti.com/automotive
DSP dsp.ti.com Broadband www.ti.com/broadband
Interface interface.ti.com Digital Control www.ti.com/digitalcontrol
Logic logic.ti.com Military www.ti.com/military
Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork
Microcontrollers microcontroller.ti.com Security www.ti.com/security
RFID www.ti-rfid.com Telephony www.ti.com/telephony
Low Power www.ti.com/lpw Video & Imaging www.ti.com/video Wireless
Wireless www.ti.com/wireless
Copyright © 2007, Texas Instruments Incorporated
Products Applications
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.