User's Guide SLWU028B–January 2006–Revised November 2006

1 Overview

This manual assists users in using the ADS5525/27/45/46/47 evaluation module (EVM) for evaluating the performance of the ADS5525/27/45/46/47 (ADCs). The EVM provides a powerful and robust capability in evaluation of the many features of the ADCs and the performance of the device der many conditions.

1.1 EVM Basic Functions

Analog input to the ADC is provided via external SMA connectors. The user supplies a single-ended input, which is converted into a differential signal. One input path uses a differential amplifier, while the other input is transformer-coupled.

The EVM provides an external SMA connector for input of the ADC clock. The single-ended input is converted into a differential signal at the input of the device.

Digital output from the EVM is via a 40-pin connector.

Power connections to the EVM are via banana jack sockets. Separate sockets are provided for the ADC analog and digital supplies, the FPGA supply, and the differential amplifier supply.

CAUTION

Exceeding the maximum input voltages can damage EVM components. Undervoltage may cause improper operation of some or all of the EVM components.

Xilinx, Spartan, WebPACK are trademarks of Xilinx, Inc. All other trademarks are the property of their respective owners.

Page 6 of the Texas Instruments 45 user manual — 2.2 EVM CMOS Output Mode Quick Start
Page 6 · click to enlarge
Page 6

EVM Quick Start Guide

2 EVM Quick Start Guide

The ADC has two basic modes of output operation, ensuring compatibility in a broad range of systems. Follow the steps below to get the EVM operating quickly with the ADC in either DDR LVDS output mode or CMOS output mode.

2.1 EVM LVDS Output Mode Quick Start (Default)

1. Ensure a jumper is installed between pins 1 and 2 on JP2. 2. Ensure DIP switch SW1, switch 2 is set to LVDS. 3. Ensure DIP switch SW1, switch 8 is set to PARALLEL. 4. Use a regulated power supply to provide 3.3 VDC to the ADC at J11 and J15, with the corresponding returns connected to J9 and J16. 5. Use a regulated power supply to provide a 5-VDC input to J14, while connecting the return to J17. 6. Provide a filtered, low-phase-noise, sinusoidal 1.5-Vrms, 170-MHz clock to J7. 7. Provide a filtered, sinusoidal analog input to J3. 8. Using a logic analyzer and Table 3 in this manual, monitor the ADC output on J4.

2.2 EVM CMOS Output Mode Quick Start

1. Ensure a jumper is installed between pins 2 and 3 on JP2. 2. Ensure DIP switch SW1, switch 2 is set to CMOS. 3. Ensure DIP switch SW1, switch 8 is set to PARALLEL. 4. Use a regulated power supply to provide 3.3 VDC to the ADC at J11 and J15, with the corresponding returns connected to J9 and J16. 5. Use a regulated power supply to provide a 5-VDC input to J14, while connecting the return to J17. 6. Provide a low-phase-noise, sinusoidal 1.5-Vrms, 170-MHz clock to J7. 7. Provide a filtered sinusoidal analog input to J3. 8. Briefly depress S1, which resets the EVM. 9. Using a logic analyzer and Table 3 in this manual, monitor the ADC output on J4.

Page 7 of the Texas Instruments 45 user manual — 3.2.2 Power
Page 7 · click to enlarge
Page 7

3 Circuit Description

3.1 Schematic Diagram

The schematic diagram for the EVM is in Section 5.3 of this document.

3.2 Circuit Function

The following paragraphs describe the function of individual circuits. See the data sheet for complete device operating characteristics.

3.2.1 Configuration Options

The EVM provides a DIP switch, SW1, to control many of the modes of operation when the EVM is configured for parallel-mode operation. Table 1 describes the functionality of the DIP switches.

Table 1. DIP Switch SW1

SW1 SWITCH NUMBEROFFONDESCRIPTION 12s complementOffset binaryDetermines device output format 2LVDSCMOSDetermines device output mode 3ReservedReservedReserved 4Internal referenceExternal referenceWhen set to External Reference, ADC uses common-mode voltage on TP1. 5Edge = 1Edge = 2Allows for output edge programmability 6Edge = 3Edge = 4Allows for output edge programmability 7NormalPower downAllows for power down 8SerialParallelDetermines mode for register interface

By switching SW1, switch 8 to OFF, the ADC operates in serial mode, using its programmed register contents. A complete register map can be found in the device datasheet. Three pins on header J6 have been reserved for programming the device while it operates in serial mode. To program the device registers using header J6, place SCLK on pin 21, SDATA on pin 23, and SEN on pin 25. A pattern generator can be used to generate the patterns needed for programming. Alternatively, TI provides an optional USB daughtercard that plugs into the expansion slot of the EVM. The USB daughtercard allows ADC register control via a software package loaded onto the PC.

3.2.2 Power

Power is supplied to the EVM via banana jack sockets. The EVM offers the capability to supply analog and digital 3.3 V independently to the ADC. Table 2 offers a snapshot of the power-supply options. All supply connections are required for default operation, except J12, J10, J13, and J20.

The EVM provides local decoupling for the ADC; however, the ADC features internal decoupling, and in many cases minimal external decoupling can be used without loss in performance. Users are encouraged to experiment to find the optimal amount of external decoupling required for their application. Figure 1 shows the ADS5547 LVDS-mode performance with all of the decoupling capacitors installed and the performance with C4, C5, C6, C7, C8, C9, and C10 removed. By default, the EVM comes with all of the decoupling capacitors installed.

Circuit Description

Page 8 of the Texas Instruments 45 user manual — G001
Page 8 · click to enlarge
Page 8

Table 2. EVM Power Options

BANANA JACKNAMEVOLTAGEDESCRIPTION J9Device AGNDGND J10AGNDGND J11Device AVDD3.3Device analog supply J12Amplifier negative rail–5THS4509 Vs– supply J13Amplifier positive rail5THS4509 Vs+ supply J14Auxiliary power5Supplies power to all peripheral circuitry including the FPGA and PROM. Voltages rails are created by using TI's TPS75003 voltage regulator. J15Device DVDD3.3Device internal digital output supply J16DGNDGND J17DGNDGND J20If TP11, TP12, and TP13 are tied low, the TPS75003 is disabled. In this case, one can supply 3.3 V to pin 1, 1.2 V to pin 2, and 2.2 V to pin 3 of J20 while connecting the ground to J17.
Texas Instruments 45 — Table 2. EVM Power Options diagram (page 8)
Fig. 1 · Table 2. EVM Power Options
Texas Instruments 45 — Table 2. EVM Power Options diagram (page 8)
Fig. 2 · Table 2. EVM Power Options

SNR − Signal-to-Noise Ratio − dBFS

9.97 19.94 30.13 40.33 50.13 60.13 69.59 79.87 89.75 100.33 130.13 170.13 68

fIN − Input Frequency − MHz

G001

Figure 1. ADS5547 SNR Performance vs Decoupling

3.2.3 Analog Inputs

The EVM can be configured to provide the ADC with either transformer-coupled or differential amplifier inputs from a single-ended source. The inputs are provided via SMA connector J3 for transformer-coupled input or SMA connector J1 for differential amplifier input. To set up for one of these options, the EVM must be configured as follows: 1. For a 1:1 transformer-coupled input to the ADC, a single-ended source is connected to J3. Confirm that SJP4 has pins 2 and 3 shorted, and that SJP5 has pins 2 and 3 shorted. The transformer used, the Mini-Circuits TC4-1W, forms an inherent band-pass filter with a pass band from 3 MHz to 800 MHz. This is the default configuration for the EVM. 2. One can use a TI THS4509 amplifier to drive the ADC by applying an input to J1. Reconfigure SJP4 and SJP5 such that both have pins 1 and 2 shorted. A 5-VDC supply must be connected to the board to provide power to U3 for this configuration. The THS4509 amplifier path converts a single-ended signal presented on J1 into a differential signal.

Circuit Description

Page 9 of the Texas Instruments 45 user manual — 3.2.5 Digital Outputs
Page 9 · click to enlarge
Page 9

The schematics present various interface options between the amplifier and the ADC. Depending on the input frequencies of interest, further performance optimization can be had by designing a corresponding filter. In its default configuration, R43, R44, and C119 form a first-order, low-pass filter with a cutoff frequency of 70 MHz. Figure 2 shows the performance of the ADS5545 using the THS4509 path.

Texas Instruments 45 — 3.2.4 Clock Input diagram (page 9)
Fig. 3 · 3.2.4 Clock Input

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

f − Frequency − MHz

G002

Figure 2. THS4509 + ADS5545 EVM Performance

3.2.4 Clock Input

A single-ended, harmonically filtered, low-phase-noise, 1.5-Vrms sinusoidal input should be applied to J7. The frequency must not exceed the device specification. In the EVM default configuration, both SPJ1 and SJP2 must have pins 1 and 2 shorted.

In the board default configuration, the transformer provides single-ended to differential conversion. The transformer has an impedance ratio of 4.

3.2.5 Digital Outputs

For compatibility with a broad range of logic analyzers, the EVM outputs 3.3-V parallel CMOS data on header J4, independent of the ADC operational mode. The Xilinx™Spartan™-3E FPGA provides the necessary translation, and it configures itself using one of two different logic files stored in the PROM, based on the EVM configuration. The CMOS data output of the FPGA is contained in data header J4 and is a standard 40-pin header on a 100-mil grid, which allows easy connection to a logic analyzer. The connector pinout is listed in Table 3. For quick setup, the eye diagram is shown in Figure 3. No setup or hold-time adjustments must be made to the logic analyzer if using the rising edge of the output clock to latch in the data.

Show 16 more labels / short text on this page
Circuit Description · −10 · −20 · −30 · −40 · Amplitude − dBFS · −50 · −60 · −70 · −80 · −90 · −100 · −110 · −120 · −130 · −135
Page 10 of the Texas Instruments 45 user manual — Table 3. Output Connector J4
Page 10 · click to enlarge
Page 10

Table 3. Output Connector J4

J4 PINADS5525/27 DESCRIPTIONADS5545/46/47 DESCRIPTION 1CLKCLK 2GNDGND 3NCNC 4GNDGND 5ReservedReserved 6GNDGND 7ReservedReserved 8GNDGND 9NCData bit 0 (LSB) 10GNDGND 11NCData bit 1 12GNDGND 13Data bit 0 (LSB)Data bit 2 14GNDGND 15Data bit 1Data bit 3 16GNDGND 17Data bit 2Data bit 4 18GNDGND 19Data bit 3Data bit 5 20GNDGND 21Data bit 4Data bit 6 22GNDGND 23Data bit 5Data bit 7 24GNDGND 25Data bit 6Data bit 8 26GNDGND 27Data bit 7Data bit 9 28GNDGND 29Data bit 8Data bit 10 30GNDGND 31Data bit 9Data bit 11 32GNDGND 33Data bit 10Data bit 12 34GNDGND 35Data bit 11 (MSB)Data bit 13 (MSB) 36GNDGND 37NCNC 38GNDGND 39NCNC 40GNDGND
Texas Instruments 45 — Table 3. Output Connector J4 diagram (page 10)
Fig. 4 · Table 3. Output Connector J4

Circuit Description

Page 11 of the Texas Instruments 45 user manual — 3.2.6 Test Points
Page 11 · click to enlarge
Page 11
Texas Instruments 45 — 3.2.6 Test Points diagram (page 11)
Fig. 5 · 3.2.6 Test Points

Figure 3. Eye Diagram of Data on Header J4.

3.2.6 Test Points

For added EVM visibility and control, several test points are provided. Table 4 summarizes the test points available.

Circuit Description

Page 12 of the Texas Instruments 45 user manual — CAUTION
Page 12 · click to enlarge
Page 12

Table 4. Test Points

TPDESCRIPTION TP1ADC common mode, input or output depending on the setting of SW1, switch 4 TP3THS4509 power down TP4ADC output enable TP5AGND TP6AGND TP7AGND TP8DGND TP9FPGA M0 pin; determines which FPGA logic file to load TP10ADC SCLK TP11TPS75003 1.2 enable TP12TPS75003 2.5 enable TP13TPS75003 3.3 enable

3.2.7 LED Operation

To give greater visibility into the EVM operations, two LEDs are provided, D3 and D4. On power up, D4 is asserted when a successful FPGA boot up is complete. For correct EVM operation, the LED should be asserted at all times. LED D3 is asserted when the ADC and FPGA are operating and decoding in DDR LVDS mode, and is not asserted when the ADC is functioning in CMOS mode. Furthermore, in either DDR LVDS mode or CMOS mode, LED D3 blinks when an ADC overrange condition occurs.

CAUTION

If LED D3 is blinking, the amplitude coming into the ADC input (J3 or J4) must be attenuated immediately; otherwise, damage to the ADC could occur.

Circuit Description

Page 13 of the Texas Instruments 45 user manual — 4.3 Optional USB SPI Interface
Page 13 · click to enlarge
Page 13

4 Expansion Options

The EVM offers several exciting possibilities to expand the capabilities of the EVM. This allows the utmost flexibility when prototyping an ADC circuit under conditions that mimic the end system, without the need to develop a custom prototype board.

4.1 Custom FPGA Code

Using a standard JTAG interface on JP1, users have the ability to load custom logic onto the FPGA, rapidly speeding up digital development time. This allows the flexibility of prototyping and debugging an ADC digital interface design before developing application-specific hardware.

To take advantage of the onboard FPGA, users can download the free Xilinx WebPACK™from the Xilinx Web site. Select the XC3S250E-4FT256 as the FPGA and the XCF16PFSG48 as the PROM.

Schematically, the FPGA is configured in BPI mode, and it samples FPGA pins M2, M1, and M0 when the FPGA's INIT_B is brought low. Depending of the status of M0, it boots from either the top or the bottom of the PROM contents. The PROM allows for the storage of two FPGA bit files. In its default condition, the EVM stores one file for ADC CMOS output at the beginning of the PROM address space and one file for ADC LVDS output at the end of the PROM address space.

4.2 Expansion Slot

For those users who make use of a custom FPGA program on the EVM, J5 and J6 provide an expansion-slot capability. Users can design daughtercards or breakout boards to make use of the unused FPGA I/O pins which are brought out to the headers.

4.3 Optional USB SPI Interface

In most cases, users can use the ADC parallel interface mode to change the operational modes of the ADC. For users requiring SPI control of the ADC, TI has developed an optional USB daughter card that plugs into the expansion slot. With the USB daughter card, users can use a PC interface to communicate to the ADC three-wire SPI interface, which allows for complete control of the ADC register map. Contact the factory for this optional accessory.

Expansion Options

Page 14 of the Texas Instruments 45 user manual — K001
Page 14 · click to enlarge
Page 14

This chapter describes the physical characteristics and PCB layout of the EVM.

5.1 PCB Layout

The EVM is constructed on a 6-layer, 0.062-inch thick PCB using FR-4 material. The individual layers are shown in Figure 4 through Figure 9. The layout features split analog and digital ground planes; however, similar performance can be had with careful layout using a single ground plane. Users can connect the analog and digital ground planes underneath the EVM by soldering the two exposed tinned strips together.

Texas Instruments 45 — 5.1 PCB Layout diagram (page 14)
Fig. 6 · 5.1 PCB Layout

K001

Figure 4. Top Layer

Page 15 of the Texas Instruments 45 user manual — K002
Page 15 · click to enlarge
Page 15
Texas Instruments 45 — 5 Physical Description diagram (page 15)
Fig. 7 · 5 Physical Description

K002

Figure 5. Layer 2, Ground Plane

Page 16 of the Texas Instruments 45 user manual — K003
Page 16 · click to enlarge
Page 16
Texas Instruments 45 — 5 Physical Description diagram (page 16)
Fig. 8 · 5 Physical Description

K003

Figure 6. Layer 3, Power Plane #1

Page 17 of the Texas Instruments 45 user manual — K004
Page 17 · click to enlarge
Page 17
Texas Instruments 45 — 5 Physical Description diagram (page 17)
Fig. 9 · 5 Physical Description

K004

Figure 7. Layer 4, Power Plane #2

Page 18 of the Texas Instruments 45 user manual — K005
Page 18 · click to enlarge
Page 18
Texas Instruments 45 — 5 Physical Description diagram (page 18)
Fig. 10 · 5 Physical Description

K005

Figure 8. Layer 5, Ground Plane

Page 19 of the Texas Instruments 45 user manual — K006
Page 19 · click to enlarge
Page 19
Texas Instruments 45 — 5 Physical Description diagram (page 19)
Fig. 11 · 5 Physical Description

K006

Figure 9. Layer 6, Bottom Layer

Page 20 of the Texas Instruments 45 user manual — 5.2 Bill of Materials
Page 20 · click to enlarge
Page 20

5.2 Bill of Materials

Page 21 of the Texas Instruments 45 user manual — CAPACITORS
Page 21 · click to enlarge
Page 21

Table 5. Bill of Materials

NOT VALUE FOOTPRINT QTY PART NUMBER VENDOR DIGI-KEY NUMBER REF DESIGNATOR INSTALLED

CAPACITORS

47-µF, tantalum, 20%, 10-V 7343 4 ECS-T1AD476R Panasonic PCS2476CT-ND C65, C66, C68, C69

10-µF, 10-V, 20% 3528 5 ECS-T1AX106R Panasonic PCS2106CT-ND C70, C71, C72, C73, C74

10-µF, 10-V, 20% 3216 2 ECS-T1AY106R Panasonic P11309CT-ND C8, C9

100-µF, 6.3-V, 10% 6032 2 TPSC107K006R0150 AVX 478-1764-2-ND C35, C60

0.1-µF, 16-V, 10% 805 2 ECJ-2VB1C104K Panasonic PCC1812CT-ND C115, C116

2.2-µF, 6.3-V, 10% 805 1 ECJ-GVB0J225K Panasonic PCC2310CT-ND C117

10-µF, 6.3-V, 10% 805 4 GRM21BR60J106KE19L Murata 490-1717-1-ND C13, C30, C40, C41

0.01-µF, 16-V, 10% 603 1 ECJ-1VB1C103K Panasonic PCC1750CT-ND C57

0.1-µF, 16-V, 10% 603 18 ECJ-1VB1C104K Panasonic PCC1762CT-ND C14, C15, C18, C25, C52 C26, C27, C28, C32, C33, C34, C36, C37, C38, C39, C51, C55, C62, C113

1.5-nF, 50-V, 10% 603 3 C1608X7R1H152K TDX C31, C58, C59

10-pF, 50-V, ±0.5-pF 603 1 ECJ-1VC1H100D Panasonic PCC100CVCT-ND C53

1-µF, 6.3-V, 10% 603 1 ECJ-1VB0J105K Panasonic PCC1915CT-ND C64

10-µF, 6.3-V, 20% 603 1 ECJ-1VB0J106M Panasonic PCC2395CT-ND C63

100-µF, 4-V, 20% 603 1 NOJC107M004RWJ AVX 478-1824-1-ND C61

2.2-µF, 6.3-V, 10% 603 13 ECJ-1VB0J225K Panasonic PCC2273CT-ND C85–C96, C114

18-pF, 50-V, 5% 603 1 GRM1885C1H180JA01D Murata 490-1409-1-ND C119 C2, C118

2-pF, 100-V, ±0.25-pF 603 0 GQM1885C2A2R0CB01D Murata 490-3555-1-ND C20

0.1-µF, 16-V, +80/–20% 402 14 ECJ-0EF1C104Z Panasonic PCC1731CT-ND C1, C3, C4, C5, C6, C7, C10, C11, C12, C16, C17, C19, C29, C44, C49

0.22-µF, 6.3-V , ±10% 402 17 ECJ-0EB0J224K Panasonic PCC2269CT-ND C42, C43, C46, C48, C50, C54, C67, C75, C76, C77, C78, C79, C80, C81, C82, C83, C84

0.022-µF, 6.3-V, +80/–20% 201 16 02016G223ZAT2A AVX 478-1054-1-ND C97, C98, C99, C100, C101, C102, C103, C104, C105, C106, C107, C108, C109, C110, C111, C112

Page 22 of the Texas Instruments 45 user manual — RESISTORS
Page 22 · click to enlarge
Page 22

Table 5. Bill of Materials (continued)

NOT VALUE FOOTPRINT QTY PART NUMBER VENDOR DIGI-KEY NUMBER REF DESIGNATOR INSTALLED

RESISTORS

0-Ω, 1/10-W, 5% 603 7 ERJ-3GEY0R00V Panasonic P0.0GCT-ND R5, R6, R10, R18, R54, R56 R48, R58, R82

0-Ω, 1/10-W, 5% 402 3 ERJ-GE0R00X Panasonic P0.0JCT-ND R11, C45, C47

4.02-Ω, 1/10-W 1% 603 2 9C06031A4R02FGHFT Yageo 311-4.02HCT-ND R37, R38

20-Ω, 1/16-W, 1% 603 1 ERJ-3EKF20R0V Panasonic P20.0HCT-ND R79

24.9-Ω, 1/16-W, 1% 603 1 ERJ-3EKF24R9V Panasonic P24.9HCT-ND R17

4.7-Ω, 1/2-W, 5% 603 2 ERD-S1TJ4R7V Panasonic P4.7BBCT-ND R44, R47

36-Ω, 1/10-W, 1% 603 0 RC0603FR-0736RL Yaego 311-36.0HRCT-ND R12, R13

49.9-Ω, 1/16-W, 1% 603 2 ERJ-3EKF49R9V Panasonic P49.9HCT-ND R35, R36 R34, R59

100-Ω, 1/16-W, 0.1% 603 3 ERA-3YEB100V Panasonic P100YCT-ND R31, R41, R60

200-Ω, 1/16-W, 1% 603 2 ERJ-3EKF2000V Panasonic P200HCT-ND R15, R16 R85, R86

330-Ω, 1/16-W, 5% 603 3 ERA-V33J331V Panasonic P330CHCT-ND R45, R87, R88

499-Ω, 1/16-W, 1% 603 2 ERJ-3EKF4990V Panasonic P499HCT-ND R83, R84

10-kΩ, 1/16-W, 1% 603 11 ERJ-3EKF1002V Panasonic P10.0KHCT-ND R2, R3, R4, R7, R8, R9, R26, R32, R33, R39, R40

4.75-kΩ, 1/16-W, 1% 603 2 ERJ-3EKF4751V Panasonic P4.75KHCT-ND R46, R49

15.4-kΩ, 1/16-W, 1% 603 1 ERJ-3EKF1542V Panasonic P15.4KHCT-ND R65

20-kΩ, 1/16-W, 1% 603 3 ERJ-3EKF2002V Panasonic P20.0KHCT-ND R30, R80, R81

36.5-kΩ, 1/16-W, 1% 603 1 ERJ-3EKF3652V Panasonic P36.5KHCT-ND R66

56.2-kΩ, 1/16-W, 1% 603 1 ERJ-3EKF5622V Panasonic P56.2KHCT-ND R1

4.99-kΩ, 1/16-W, 1% 603 3 ERJ-3EKF4991V Panasonic P4.99KHCT-ND R27, R28, R29

61.9-kΩ, 1/16-W, 1% 603 2 ERJ-3EKF6192V Panasonic P61.9KHCT-ND R63, R64

0.033-Ω, 1/4-W, 5% 805 2 RL1220T-R033-J Susumu Co,. Ltd. RL12T.033JCT-ND R61, R62

348-Ω, 1/16-W, 1% 402 2 ERJ-2RKF3480X Panasonic P348LCT-ND R24, R25

49.9-Ω, 1/16-W, 1% 402 3 ERJ-2RKF49R9X Panasonic P49.9LCT-ND R19, R42, R43

78.7-Ω, 1/16-W, 1% 402 2 ERJ-2RKF78R7X Panasonic P78.7LCT-ND R20, R21

100-Ω, 1/16-W, 1% 402 2 ERJ-2RKF1000X Panasonic P100LCT-ND R22, R23

20-ΩR-pack, 5%, 0.063-W CTS-742_8RES 2 742C163220JTR CTS 742C163220JCT-ND RP1, RP2

10-kΩresistor pack CTS_742_8RES 1 742C163103JTR CTS 742C163103JCT-ND RP3

Page 23 of the Texas Instruments 45 user manual — Table 5. Bill of Materials (continued)
Page 23 · click to enlarge
Page 23

Table 5. Bill of Materials (continued)

NOT VALUE FOOTPRINT QTY PART NUMBER VENDOR DIGI-KEY NUMBER REF DESIGNATOR INSTALLED

FERRITE BEADS, CONNECTORS, JUMPERS, JACKS, ICs, ETC.

Ferrite bead 1206 5 EXC-ML32A680U Panasonic P10437CT-ND FB2, FB3, FB4, FB6, FB8, FB9, FB7 FB10

Inductor, SMT, 15-µH, 2.6-A COIL-CDRH8D43 1 CDRH8D43-150 Sumida L1

Inductor, SMT, 5-µH, 2.9-A COIL-CDRH6D38 1 CDRH6D38-5R0 Sumida CDRH6D38-5R0NC-ND L2

0.0-Ω, 1/8-W, 5% resistor 805 2 ERJ-6GEY0R00V Panasonic P0.0ACT-ND L3, L4

Red test point Test_point2 8 5000k Keystone 5000K-ND TP1, TP4, TP9, TP10 TP3 TP11 TP12 TP13

Black test point Test_point2 4 5001k Keystone 5000K-ND TP5 TP6 TP7 TP8

40-pin header 20×2×.1 1 HTSW-120-07-L-D Samtec J4

40-pin header smt 20X2_SMT_MMS_ 2 MMS-120-02-T-DV Samtec J5, J6 SAMTEC

Red banana jacks BANANA_JACK 5 ST-351A Allied N/A J11, J12, J13, J14, J15

Black banana jacks BANANA_JACK 4 ST-351B Allied N/A J9, J10, J16, J17

SMA connectors SMA_Jack 3 901-144-8RFX AMP ARFX1231-ND J1, J3, J7 J8

3POS_header 3pos_jumper 1 HTSW-150-07-L-S Samtec JP2(1)

6-pin header 6×1×.1 1 HTSW-120-07-L-D Samtec JP1

3-pin power connector 3term_screw_con 0 93F7124 Newark J20

Transformer TC4-1W_ 3 TC4-1W Mini-Circuits T1, T2, T3 TRANSFORMER

Diode, Schottky, 1-A, 20-V DIODE-MBRM120 1 MBRM120E ON Semiconductor D2

Diode, Schottky, 3-A, 20-V DO-214AB(SMC) 1 SS32 Vishay D1

Green SM_LED_1206 LED-1206 2 CMD15-21VGC/TR8 Panasonic L62205CT-ND D3, D4

MOSFET, P-CH, 20-V, 4.7-A, 3-SOT-23 2 SI2323DS Vishay Q1, Q2 39-MΩ

TRANS BIAS NPN, 50-V SOT416 1 DTC114EET1 ON Semiconductor DTC114EET1OS-ND Q3

Switch EVQ-PJ 1 EVQ-PJX04M Panasonic P8050SCT-ND S1

Switch, 8-Pos, half-pitch SMT SWITCH_8POS_ 1 TDA08H0SK1 ITT CKN1365-ND SW1 SMT

3-circuit jumpers SJP3_RESISTOR 2 ERJ-3GEY0R00V Panasonic P0.0GCT-ND SJP4(2), SJP5(3)

3-circuit jumpers SJP3_402 2 ERJ-2GE0R00X Panasonic P0.0JCT-ND SJP1(4), SJP2(5)

(1) Add jumper for JP2 between pins 1 to 2. (2) Add jumper for SJP4 between pins 2 and 3 (use a 0-Ωresistor to short pins). (3) Add jumper for SJP5 between pins 2 and 3 (use a 0-Ωresistor to short pins). (4) Add jumper for SJP1 between pins 1 and 2 (use a 0-Ωresistor to short pins). (5) Add jumper for SJP2 between pins 1 and 2 (use a 0-Ωresistor to short pins).

Page 24 of the Texas Instruments 45 user manual — Table 5. Bill of Materials (continued)
Page 24 · click to enlarge
Page 24

Table 5. Bill of Materials (continued)

Texas Instruments 45 — Table 5. Bill of Materials (continued) diagram (page 24)
Fig. 12 · Table 5. Bill of Materials (continued)

NOT VALUE FOOTPRINT QTY PART NUMBER VENDOR DIGI-KEY NUMBER REF DESIGNATOR INSTALLED

IC amp, fully-diff, wideband 16-QFN(RGT) 1 THS4509RGTT TI 296-17730-1-ND U3

IC, pwr-mgmt, triple-supply 20-pin-QFN 1 TPS75003RHLR TI 296-17835-2-ND U6

IC, LDO reg, hi-PSRR, 1.8-V 5-SOT(DBV) 1 TPS73018DBVT TI 296-17577-1-ND U7

IC, comparator, R-R, hi-spd 8-TSSOP(DCN) 1 TLV3502AIDCNT TI 296-18147-2-ND U9

IC, EX-OR gate, 2-in 5-SOT(DBV) 1 SN74LVC1G86DBVR TI 296-9853-1-ND U10

Screw 4-40 × 3/8" 4 N/A Building Fasteners H781-ND

Standoff, hex (1/4 x .5") 4-40 screw 4 N/A Keystone 1902CK-ND

Page 25 of the Texas Instruments 45 user manual — 5.3 PCB Schematics
Page 25 · click to enlarge
Page 25

5.3 PCB Schematics

The schematics for the EVM are on the following pages.

Page 26 of the Texas Instruments 45 user manual — U1-H6
Page 26 · click to enlarge
Page 26
Texas Instruments 45 — ADS5525_45_46-Sch_revB1.pdf diagram (page 26)
Fig. 13 · ADS5525_45_46-Sch_revB1.pdf

B

A

XILINX XC3S500E_FT256

U2A

AGND 25 AVDD 26 SEN 27 SDATA 28 SCLK 29 RESET 30 N/C 31 N/C 32 D0_D1M 33 D0_D1P 34 DRVDD 35 DRGND 36

D2_D3M 37 D2_D3P 38 D4_D5M 39 D4_D5P 40 D6_D7M 41 D6_D7P 42 D8_D9M 43 D8_D9P 44 D10_D11M 45 D10_D11P 46 D12_D13M 47 D12_D13P 48

SN74LVC1G86

.1uF

R27

4.99K

.1uF

U10

10K

R3

2.2uF

+ C9

.1uF

U1-H6

U1-H5

DFS

V+ 8

OUT A 7

OUT B 6

-IN B 4 V5

TLV3502

U9

U1-H6

U1-H5

+IN A 1

-IN A 2

+IN B 3

DFS

R32

10K

R33

10K

R39

10K

R40

10K

DRVDD

B

Show 7 more labels / short text on this page
(Sh 4) · (Sh 4) · (Sh 4) · 10uF · DFS (Sh 4) · (Sh 4) · (Sh 4)
Page 27 of the Texas Instruments 45 user manual — J3
Page 27 · click to enlarge
Page 27

D

Texas Instruments 45 — D diagram (page 27)
Fig. 14

B

A

6 5 4 3 2 1

C44 .1uF

.1uF

R15

.1uF

SMA_END

VCM

2 3 4 5

J1

TC4-1W

T1

R34

2 3 4 5

J3

AIN

D

B

A

VCM (Sh 1)

Page 28 of the Texas Instruments 45 user manual — D
Page 28 · click to enlarge
Page 28

D

B

A

B

SHEET: OF: SIZE: DATE:

12500 TI Boulevard. Dallas, Texas 75243

REV:

DOCUMENTCONTROL # ADS5545

6 5 4 3 2 1

1 2 3 4 5 6

Engineer: ti

Title:

Y. DEWONCK Note 1. Part not installed

J. VENABLE

Drawn By:

FILE:

CLKP

CLKP

CLKM

SJP2

CLKM

.1uF

.1uF

2 SJP1

R31

R60

1 2 R54

R56 0

TC4-1W

T3

R59

R58

CLK_INP

2 3 4 5

J7

CLK_INM

J8

2 3 4 5

D

B

A

Show 9 more labels / short text on this page
11-Jul-2006 · (Sh 1) · (Sh 1) · (1-2) · (1-2) · (Note 1) · (Note 1) · (Note 1) · (Note 1)
Page 29 of the Texas Instruments 45 user manual — 40PIN_IDC
Page 29 · click to enlarge
Page 29
Texas Instruments 45 — ADS5525_45_46-Sch_revB4.pdf diagram (page 29)
Fig. 15 · ADS5525_45_46-Sch_revB4.pdf

1 16 2 15 3 14 4 13 5

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

ADC_D10

ADC_D11

ADC_D12

ADC_D14

ADC_D15

ADC_D0

ADC_D1

ADC_D2

ADC_D3

ADC_D4

ADC_D5

ADC_D6

ADC_D7

ADC_D8

ADC_D9

ADC_D10

ADC_D11 ADC_D12 ADC_D13

BUSY BUSY (Sh 5)

ADC_D7

ADC_D8

ADC_D9

1 16 2 15 3 14 4 13 5

8 10 11 7

1 16 2 15 3 14 4 13 5

8 10 11 7

RP1

RP2

ADC_D14

ADC_D15

CLKOUT

INIT_B INIT_B (Sh 5)

R79

CCLK CCLK (Sh 5)

M0

A23 A23 (Sh 5)

D0

D1

D2

D3

D4

D5

D6

D7

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40

40PIN_IDC

J4

M0

D0

D1

D2

D3

D4

D5

D6

D7

D

B

A

Show 4 more labels / short text on this page
20 Ohm · 20 Ohm · (Sh 1) · (Sh 5)
Page 30 of the Texas Instruments 45 user manual — FILE:
Page 30 · click to enlarge
Page 30

D

B

A

B

SHEET: OF: SIZE: DATE:

12500 TI Boulevard. Dallas, Texas 75243

REV:

DOCUMENTCONTROL # ADS5545

1 2 3 4 5 6

Engineer: ti

Title:

Y. DEWONCK Note 1. Part not installed

J. VENABLE

Texas Instruments 45 — J. VENABLE diagram (page 30)
Fig. 16

Drawn By:

FILE:

TCLK GND 3.3V

TMS TDI TDO

OE/RESET__ A3

CLK B3

CE__ B4

BUSY C1

CLKOUT C2

D1 H5 D0 H6

D2 E5

D3 D5 VCCO D6

D4 C5

D5 B5

D6 A5

D7 A6

CF__ D1

CEO__ D2

TMS E2

TDO E6

TDI G1

DNC G2 REV_SEL0 G3

REV_SEL1 G4

TCK H3

EN_EXT_SEL__ H4

XCF16PFSG48

U4

VCCINT B1

VCCINT E1

VCCINT G6

VCCO B2

VCCO C6

VCCO G5

VCCJ H2

DNC A4

DNC C3

DNC C4

DNC D3

DNC D4

DNC E3

DNC E4

DNC F2

DNC F3

DNC F4

GND A1

GND A2

GND B6

GND F1

GND F5

GND F6

GND H1

D

B

A

11-Jul-2006 · (Sh 3)

Page 31 of the Texas Instruments 45 user manual — CON_3TERM_SCREW
Page 31 · click to enlarge
Page 31

D

Texas Instruments 45 — D diagram (page 31)
Fig. 17

B

A

1 2 3 4 5 6

A ti

BANK 0 DECOUPLING VCCO_0

+ C60

Texas Instruments 45 — BANK 0 DECOUPLING VCCO_0 diagram (page 31)
Fig. 18

2.2uF

5V 1.8V

OUT 5

EN 3 NR 4

TPS73018DBV

U7

GND 2

IN 1

1.5nF

EN1 17

EN2 4

AGND 18

EN3 3

OUT3 1

SS3

SS3 19

IN3 20

FB3 2

TP13

.01uF

TP12

.1uF

TP11

FB3

R82

R9

10K

R26

10K

R63

61.9K

R65

15.4K

10K

R8

CON_3TERM_SCREW

J20

D

B

1uF · 100uF · 10uF

Page 32 of the Texas Instruments 45 user manual — RED
Page 32 · click to enlarge
Page 32

D

B

A

B

SHEET: OF: SIZE: DATE:

12500 TI Boulevard. Dallas, Texas 75243

REV:

ADS5545

6 5 4 3 2 1

1 2 3 4 5 6

DOCUMENTCONTROL #

Engineer: ti

Title:

FPGA POWER SUPPLY(5V)

Y. DEWONCK

Diff Amp Positive Supply (+5.0V)

J. VENABLE

Texas Instruments 45 — J. VENABLE diagram (page 32)
Fig. 19

.1uF

Drawn By:

FILE:

+VCC

FB8 FB9 FB10 (Note 1) (Note 1)

ADC DIGITAL SUPPLY(3.3V)

ADC Analog Supply (+3.3V)

.1uF

.1uF

DRVDD

AVDD

RED + C74

+ C70

+ C65

+ C69

FB7

FB2

.1uF

.1uF

OUTPUT_BUFFER

+3.3VA-PS

RED

BLACK

BLACK

J11

J15

J16

J9

D

B

A

Show 6 more labels / short text on this page
11-Jul-2006 · (Note 1) · 10uF · 10uF · 47uF · 47uF
Page 33 of the Texas Instruments 45 user manual — EVALUATION BOARD/KIT IMPORTANT NOTICE
Page 33 · click to enlarge
Page 33

EVALUATION BOARD/KIT IMPORTANT NOTICE

Texas Instruments (TI) provides the enclosed product(s) under the following conditions:

This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the product(s) must have electronics training and observe good engineering practice standards. As such, the goods being provided are not intended to be complete in terms of required design-, marketing-, and/or manufacturing-related protective considerations, including product safety and environmental measures typically found in end products that incorporate such semiconductor components or circuit boards. This evaluation board/kit does not fall within the scope of the European Union directives regarding electromagnetic compatibility, restricted substances (RoHS), recycling (WEEE), FCC, CE or UL, and therefore may not meet the technical requirements of these directives or other related directives.

Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from the date of delivery for a full refund. THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims arising from the handling or use of the goods. Due to the open construction of the product, it is the user’s responsibility to take any and all appropriate precautions with regard to electrostatic discharge.

EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.

TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive.

TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein.

Please read the User’s Guide and, specifically, the Warnings and Restrictions notice in the User’s Guide prior to handling the product. This notice contains important safety information about temperatures and voltages. For additional information on TI’s environmental and/or safety programs, please contact the TI application engineer or visit www.ti.com/esh

No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or combination in which such TI products or services might be or are used.

Page 34 of the Texas Instruments 45 user manual — Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Page 34 · click to enlarge
Page 34

FCC Warning

This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC rules, which are designed to provide reasonable protection against radio frequency interference. Operation of this equipment in other environments may cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may be required to correct this interference.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2006, Texas Instruments Incorporated

EVM WARNINGS AND RESTRICTIONS

It is important to operate this EVM within the AVDD voltage range of –0.3 V to 3.8 V and the DVDD voltage range of –0.3 V to 3.8 V.

Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are questions concerning the input range, please contact a TI field representative prior to connecting the input power.

Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the EVM. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.

During normal operation, some circuit components may have case temperatures greater than 25°C. The EVM is designed to operate properly with certain components above 50°C as long as the input and output ranges are maintained. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of devices can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during operation, please be aware that these devices may be very warm to the touch.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2006, Texas Instruments Incorporated

Page 35 of the Texas Instruments 45 user manual — IMPORTANT NOTICE
Page 35 · click to enlarge
Page 35

IMPORTANT NOTICE

Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications

Amplifiers amplifier.ti.com Audio www.ti.com/audio

Data Converters dataconverter.ti.com Automotive www.ti.com/automotive

DSP dsp.ti.com Broadband www.ti.com/broadband

Interface interface.ti.com Digital Control www.ti.com/digitalcontrol

Logic logic.ti.com Military www.ti.com/military

Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork

Microcontrollers microcontroller.ti.com Security www.ti.com/security

Low Power Wireless www.ti.com/lpw Telephony www.ti.com/telephony

Video & Imaging www.ti.com/video

Wireless www.ti.com/wireless

Mailing AddressTexas Instruments Post Office Box 655303 Dallas, Texas 75265

Copyright © 2007, Texas Instruments Incorporated

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Texas Instruments 45

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Texas Instruments 45

Be the first to ask — other owners or our team will answer.

Original document

Texas Instruments 45 manual PDF

35 pages·840 KB·Power Supply·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…