Relay PCA P/N 04523 Addendum to M100E, M200E and M400E Operator Manuals © TELEDYNE INSTRUMENTS ADVANC ED POLLUTION INSTRUMENTATION (T-API) 9480 CARROLL PARK DRI VE SAN DIEGO, CA 92121-52 01 USA Toll-free Phone: 800-324-5 190 Phone: 858-657-9 800 Fax: 858-657-9 816 Email: api-sales@teledyne.
THIS PAGE INTENTIONALLY BLANK.
Relay PCA 0452 3 Addendum to E-Series Operator Manuals SAFETY MESSAGES For general safety information please refer to your M100E/M200 E/M400E operato r’s manual. CAUTION Never disconnect electronic cir c uit boards, wiring harnesses or electroni c subassemblies while the unit is under power.
Addendum to E-Series Operator Manuals Relay PCA 0452 3 ii 05118 Rev B3 THIS PAGE INTENTIONALLY BLANK.
Relay PCA 0452 3 Addendum to E-Series Operator Manuals TABLE OF CONTENTS 1. INTROD UCTION ................................................................................................................ ........... 1 1.1. What’s the Same ...........
Addendum to E-Series Operator Manuals Relay PCA 0452 3 ii 05118 Rev B3 THIS PAGE INTENTIONALLY BLANK.
Relay PCA 0452 3 Addendum to E-Series Operator Manuals 1. INTRODUCTION This addendum documen t s a recent upgrade to the relay card installe d in some of the M100E, M200E and M400E series analyzers. S pecifically, a new relay PCA design, P/N 04523 replaces P/N 03955 and all of its versions in the following instruments.
Addendum to E-Series Operator Manuals Relay PCA 0452 3 1.2. What’s Different The major differences between the Relay PC A 04523 and Relay PCA 0 3955 are: On instruments wi th internal pumps, t he pump is now confi gured for use with 110 VAC, 60 Hz vs.
Relay PCA 0452 3 Addendum to E-Series Operator Manuals There are two versions of the new relay card. Table 1-1 above cross references the PCA version with the various E-seri es analyzer models. 1.3.1. Version 045230200 This is the most commonly u sed version of the Rela y PCA.
Addendum to E-Series Operator Manuals Relay PCA 0452 3 USER NOTES: 4 05118 Rev B3.
Relay PCA 0452 3 Addendum to E-Series Operator Manuals 2. OPERATION AND CONFIGURATION 2.1. Power Distribution SENSOR SUITES LOGIC DEVI CES (e. g . C P U , I 2 C bus, Keyboard, Di spl ay, MotherBoar d, e tc. ) RELAY PCA ON / OF F SWITCH PS 2 (+12 VDC) OPTI ONAL VALVES (e.
Addendum to E-Series Operator Manuals Relay PCA 0452 3 JP2 Main AC Hea ter Configuration JP6 IZS Perm eatio n Tu be Heater an d O 2 Sensor Connecti on.
Relay PCA 0452 3 Addendum to E-Series Operator Manuals 2.1.1.1. AC configuration – Internal Pump (JP7) AC power configur at ion for internal pumps is set u sing Jumper set JP7 (see F igu re 1- 1 for the location of JP7).
Addendum to E-Series Operator Manuals Relay PCA 0452 3 2.1.1.2. AC Configuration – Standard Heaters (JP2) Power configuration for the AC the standard heat ers is set using Jumper set JP2 (see Figure 1-1 for the location of JP 2).
Relay PCA 0452 3 Addendum to E-Series Operator Manuals 2.1.1.3. AC Configuration –Heaters for Option Packages (JP6) Both the IZS valve option or an O 2 sensor options include AC heat ers that maintain an opti mum operating temperature for key comp onents of those option s.
Addendum to E-Series Operator Manuals Relay PCA 0452 3 2.3. Status LEDs & Watch Dog Circuitry Like the previous versi on, the status LED’s on the Relay P CA 04523 includes thirteen LEDs that indicate the status of th e analyzer’s heaters, val ves and other general operating conditions.
Relay PCA 0452 3 Addendum to E-Series Operator Manuals 2.4. Heater Control Loop T he rm isto r(s) – Low T em perature Sensing : (e.g. Sample Cham ber and Reaction Cell t emperatures) RELAY PCA DC Co.
Addendum to E-Series Operator Manuals Relay PCA 0452 3 2.4.1. Thermocouple Inputs and Configuration Jumper (JP5) Although the 04523 relay PCA supports two ther mocouple inputs, the current M100E/M200E series analyzers only ut ilize one and the M 400E se ries analyzers none.
Relay PCA 0452 3 Addendum to E-Series Operator Manuals Input Gain Se lector 1 – 11 Type J Compensation 4 – 14 Output Scale Selector 2 – 12 Type J Compensation 3 – 13 Termination Selec tor 5 .
Addendum to E-Series Operator Manuals Relay PCA 0452 3 2.5. DC Power Supply Test Points The tables defining the names and functions of th e DC power test point th at appear in Chapter 11 of some revisions of the M100E/M200E/M400E op erator’s manual are incorrect.
Relay PCA 0452 3 Addendum to E-Series Operator Manuals 3. TROUBLE SHOOTING AND REPAIR General Trouble shooting hints for the relay PCA are the same as described for the previous versions for the PCA. See Chapter 11 of yo ur M100 E/M200E/M400E operator’s manual for more information.
Addendum to E-Series Operator Manuals Relay PCA 0452 3 4. SCHEMATICS AND SPARE PARTS FOR RELAY PCA P/N 04523 Table 4-1: List of Spar e Part s DOCUMENT # DOCUMENT TITLE RL0000015 Relay, DPDT, AC, Solid.
An important point after buying a device Teledyne M200E and M400E (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Teledyne M200E and M400E yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Teledyne M200E and M400E - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Teledyne M200E and M400E you will learn all the available features of the product, as well as information on its operation. The information that you get Teledyne M200E and M400E will certainly help you make a decision on the purchase.
If you already are a holder of Teledyne M200E and M400E, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Teledyne M200E and M400E.
However, one of the most important roles played by the user manual is to help in solving problems with Teledyne M200E and M400E. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Teledyne M200E and M400E along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center