ADMINISTRATOR GUIDE

D14050.04 OCTOBER 2007








Maintenance and Upgrade
ENTRYPOINT
Trademarks and Copyright 3
Maintenance – General 38 Maintenance – Upgrading the System 39 Maintenance – Option Keys, Password and Restart 40
Disclaimer, License Agreements, and Patent Information 5
Operator Safety / Environmental Issues
Default Services 42 Dial Plan Configuration 43 Argument Details for the Default DID Service 44 Argument Details for a Default IVR Service 45 Argument Details for a Default Menu Service 46 Argument Details for a Default TMS Corporate Directory (Phone Book Service) 47
Safety Instructions 7 Environmental Issues 8
Unpacking and Installation 11 Entrypoint Features at a Glance 12 The Front and Rear Panels 13 Configuring Your Entrypoint via the RS 232 14 Configuring the IP Address via the Front Panel 15
Some Dial Plan Examples (I) 49 Some Dial Plan Examples (II) 50 Secretary Service 51 TMS Corporate Directory 52 Contact Information 53
Starting Up the Entrypoint 17 An Overview of the Management Menu System 18 Service Call Details 19 Call Setup via Default Services 20 Dialling from UMTS – Using Phone Book 21
ISDN/PRI Status (PRI Versions only) 23 ISDN/BRI Status (BRI Versions only) 24 H.323 Gatekeeper Status 25 Services 26 System Information 27 System Resources 28
ISDN/PRI Configuration (ISDN/PRI Versions only) 30 ISDN/BRI Configuration (ISDN/BRI Versions only) 31 IP Configuration 32 H.323 Configuration 33 SIP Configuration 34 SNMP Configuration 35 System 36


All rights reserved. This document contains information that is proprietary to TANDBERG. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by photocopying, or otherwise, without the prior written permission of TANDBERG. Nationally and internationally recognized trademarks and trade names are the property of their respective holders and are hereby acknowledged.




Disclaimer License Agreements Patent Information
The information in this document is furnished for informational purposes only, is subject to change without prior notice, and should not be construed as a commitment by TANDBERG.
All rights reserved. This document contains information that is proprietary to TANDBERG. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by photocopying, or otherwise, without the prior written permission of TANDBERG. Nationally and internationally recognized trademarks and trade names are the property of their respective holders and are hereby acknowledged.
TANDBERG technology described in this manual is protected by one or more of the following U.S. Patent Nos. 5,584,077 - 5,838,664 - 5,600,646 - 7,010,119 - 7,034,860 and other patents are pending in the United States and/or other countries.
TANDBERG reserves the right to amend any of the information given in this document in order to take account of new developments.
Every effort has been made to supply complete and accurate information, however, TANDBERG assumes no responsibility or liability for any errors or inaccuracies that may appear in this document, nor for any infringements of patents or other rights of third parties resulting from its use. No license is granted under any patents or patent rights of TANDBERG.
Copyright © 1992, 1993, The Regents of the University of California. All rights reserved.
This code is derived from software contributed to Berkeley by Christos Zoulas of Cornell University. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
Redistributions of source code must retain the above copyright notice, • this list of conditions and the following disclaimer.
Redistributions in binary form must reproduce the above • copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
All advertising materials mentioning features or use of this • software must display the following acknowledgement:


For your own protection, please read the overleaf safety instructions completely, before operating the equipment and keep this manual for future reference. The information in this summary is intended for operators. Carefully observe all warnings, precautions and instructions both on the apparatus and in the operating instructions.

For your protection please read these safety instructions completely before you connect the equipment to the power source. Carefully observe all warnings, precautions and instructions both on the apparatus and in these operating instructions.
Never install cables, or any peripherals, • without first unplugging the device from it's power source.
Never use this apparatus, or connect/ disconnect communication cables or power cables during lightning storms.
Do not use communication equipment to report a gas leak in the vicinity of the leak.
Electromagnetic Compatibility (EMC)
Dust
Do not attempt to service the apparatus • yourself as opening or removing covers may expose you to dangerous voltages or other hazards, and will void the warranty. Refer all servicing to qualified service personnel.
Retain this manual for future reference.
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Do not operate the apparatus in areas with high concentration of dust.
Do not operate the apparatus under or near • water – for example near a bathtub, kitchen sink, or laundry tub, in a wet basement, near a swimming pool or in other areas with high humidity.
Unplug the apparatus from its power source • and refer servicing to qualified personnel under the following conditions:
Do not operate the apparatus in areas with vibration or place it on an unstable surface.
If the power cord or plug is damaged or • frayed.
Never install jacks for communication • cables in wet locations unless the jack is specifically designed for wet locations.
If liquid has been spilled into the • apparatus.
The product may have hazardous voltage • inside. Never attempt to open this product, or any peripherals connected to the product, where this action requires a tool.
If objects have fallen into the apparatus. •
This product complies with Commission Directives:
Cleaning
LVD 73/23/EEC EMC 89/336/EEC R&TTE 99/5/EEC
Unplug the apparatus from communication • lines, mains power-outlet or any power source before cleaning or polishing. Do not use liquid cleaners or aerosol cleaners. Use a lint-free cloth lightly moistened with water for cleaning the exterior of the apparatus.
This product should always be powered from • an earthed power outlet.
If the apparatus has been subjected to • excessive shock by being dropped.
This product complies with harmonized Standards:
Never connect attached power supply cord • to other products.
If the apparatus seems to be overheated. •
In case any parts of the product has visual • damage never attempt to connect mains power, or any other power source, before consulting service personnel
EN 60950-1 : 2001, A11 EN 55022 : 1994, A1/A2 EN 55024 : 1998, A1/A2 EN 61000-3-2 : 2000 EN 61000-3-3 : 1995, A1 TBR 3 Layer 1, 2 and 3 TBR4 Layer 1, 2 and 3
If the apparatus emits smoke or abnormal • odour.
Unplug the apparatus from communication • lines before cleaning or polishing. Do not use liquid cleaners or aerosol cleaners. Use a lint-free cloth lightly moistened with water for cleaning the exterior of the apparatus.
If the apparatus fails to operate in • accordance with the operating instructions.
The plug connecting the power cord to the • product/power supply serves as the main disconnect device for this equipment. The power cord must always be easily accessible.
TECHNICAL CONSTRUCTION FILE NO.: X13526
Use only accessories specified by the manufacturer, or sold with the apparatus.
Ventilation
For an official, signed version of this document, or details regarding documentation from the technical construction file, please contact TANDBERG.
Do not block any of the ventilation openings • of the apparatus. Never cover the slots and openings with a cloth or other material. Never install the apparatus near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
Route the power cord so as to avoid it being • walked on or pinched by items placed upon or against it. Pay particular attention to the plugs, receptacles and the point where the cord exits from the apparatus.
If the provided plug does not fit into your • outlet, consult an electrician.
Do not place the product in direct sunlight or • close to a surface directly heated by the sun.

Thank you for buying a product which contributes to a reduction in pollution, and thereby helps save the environment. Our products reduce the need for travel and transport and thereby reduce pollution. Our products have either none or few consumable parts (chemicals, toner, gas, paper). Our products are low energy consuming products.
Information for Recyclers
As a manufacturer of electrical and electronic equipment TANDBERG is responsible for compliance with the requirements in the European Directives 2002/96/EC (WEEE) and 2002/95/ EC (RoHS).
As part of compliance with the European WEEE Directive, TANDBERG provides recycling information on request for all types of new equipment put on the market in Europe after August 13th 2005.
The primary aim of the WEEE Directive and RoHS Directive is to reduce the impact of disposal of electrical and electronic equipment at end-of-life. The WEEE Directive aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring producers to arrange for collection and recycling. The RoHS Directive bans the use of certain heavy metals and brominated flame retardants to reduce the environmental impact of WEEE which is landfilled or incinerated.
Please contact TANDBERG and provide the following details for the product for which you would like to receive recycling information:
Environmental stewardship is important to TANDBERG’s culture. As a global company with strong corporate values, TANDBERG is committed to following international environmental legislation and designing technologies that help companies, individuals and communities creatively address environmental challenges.
TANDBERG’s environmental objectives are to:
TANDBERG has implemented necessary process changes to comply with the European RoHS Directive (2002/95/EC) and the European WEEE Directive (2002/96/EC).
TANDBERG is pleased to announce that we have replaced the printed versions of our User Guides with a digital CD version. Instead of a range of different user manuals, there is now one CD – which can be used with all TANDBERG products – in a variety of languages. The environmental benefits of this are significant. The CDs are recyclable and the savings on paper are huge. A simple web-based search feature helps you directly access the information you need. In addition, the TANDBERG video systems now have an intuitive on-screen help function, which provides a range of useful features and tips. The contents of the CD can still be printed locally, whenever needed.
In order to avoid the dissemination of hazardous substances in our environment and to diminish the pressure on natural resources, we encourage you to use the appropriate take-back systems in your area. Those systems will reuse or recycle most of the materials of your end of life equipment in a sound way.
TANDBERG products put on the market after August 2005 are marked with a crossed-out wheelie bin symbol that invites you to use those take-back systems.
Please contact your local supplier, the regional waste administration, or http://www.tandberg.net/recycling if you need more information on the collection and recycling system in your area.




















Before you start using the system we recommend that you take your time to read through this section of the User Guide to get you up and going. This section outlines how to connect the system and the basic operating principles.

Installation Site Preparations General Installation Precautions
Make sure that the Entrypoint is accessible and that all • cables can be easily connected.
To avoid damage to the unit during transportation, the Entrypoint is delivered in a special shipping box, which should contain the following components:
Never install telephone jacks in wet locations unless the • jack is specifically designed for wet locations.
For ventilation: Leave a space of at least 10cm (4 inches) • behind the Entrypoint’s rear panel and 10cm (4 inches) in front of the front panel.
Never touch uninstalled telephone wires or terminals unless • the telephone line has been disconnected at the network interface.
The room in which you install the Entrypoint should have • an ambient temperature between 0ºC and 35ºC (32ºF and 95ºF) and between 10% and 90% non-condensing relative humidity.
Avoid using a telephone (other than a cordless type) during • an electrical storm. There may be a remote risk of electrical shock from lightning.
Do not place hot objects directly on top, or directly beneath • the Entrypoint.
Do not use the telephone to report a gas leak in the vicinity • of the leak.
The socket outlet shall be installed near to the equipment • and shall be easily accessible.
You will need a CSU (Channel Service Unit) between your • system and the PRI line from your network provider.
Make sure that it is possible to receive and to make mobile • (H.324M) video calls from behind this line. Check this with your network operator!
This product complies with directives: LVD 73/23/EC, EMC • 89/366/EEC, R&TTE 99/5/EEC.
This product complies with the standards GR-63-CORE and • GR-1089-CORE and is NEBS approved by UL. For NEBS compliance, there should be a clearance of 9.1 cm between the product and any other product mounted in the rack.
If you are behind a PABX make sure that the PABX is capable • of routing mobile (H.324M) video calls.
A brief, yet detailed presentation of the procedure to get you up and going can be found in the Installation Sheet accompanying your TANDBERG product.
RS 232 cable. To control the Entrypoint using the data port, connect an RS 232 cable between the Entrypoint’s RS 232 connector and the COM-port on a PC. See Entrypoint Configuration and the Data Port Command Interface User Guide (available separately) for more on this.
LAN cable. To use the Entrypoint on IP, connect a LAN cable from the LAN 1 connector on the Entrypoint to your network. The LAN 2, 3 and 4 connectors are not used and should be left open.
Power cable. Connect the system power cable to an electrical distribution socket.


ISDN PRI or BRI cables. The E1/T1 cable should be connected to a CSU (Channel Service Unit). You will need a CSU between your Entrypoint and the PRI line from your network provider.

The TANDBERG Entrypoint enables sites on IP and UMTS Handsets to participate in meetings with each other with the quality and reliability found in all TANDBERG equipment. An Entrypoint system opens up a wide range of interactive video and call routing services.
Management Interfaces
H.324m, SIP and H.323 support •
SOAP (Simple Object Access Protocol) is a lightweight protocol for exchange of information in a decentralized, distributed environment.
Load balance. •
XML (Extensible Markup Language) is a flexible way to create common information formats and share both the format and the data on the World Wide Web, intranets, and elsewhere. This functionality can be used by management systems like the TANDBERG Management Suite to control the Entrypoint
The TANDBERG Entrypoint offers a variety of UMTS dial-in services:
Direct Inward Dialling (DID) – the destination endpoint is • determined from the dialled number
HTTP Web-interface for system management, call management such as diagnostics and software uploads
Interactive Video Response (IVR) – the destination endpoint • can be selected via touch tones.
HTTPS Hypertext Transfer Protocol over Secure Socket Layer is a Web protocol that encrypts and decrypts user page requests as well as the pages that are returned by the Web server. It uses Secure Socket Layer (SSL) as a sublayer under its regular HTTP application layering. HTTPS uses port 443 instead of HTTP port 80 in its interactions with the lower layer, TCP/IP. SSL uses a 40-bit key size for the RC4 stream encryption algorithm, which is considered an adequate degree of encryption for commercial exchange.
Due to the fixed bandwidth of UMTS video telephony every call will be limited to 64 Kbits/s. This offers a capacity of 30 simultaneous calls through an E1 PRI, 23 simultaneous calls through a T1 PRI, or 8 calls through a 4 × BRI. Due to audio transcoding (AMR to G.711) the bandwidth at IP side is 109 Kbits/s per session, 64 Kbits/s G.711 audio and 45 Kbits/s H.263 video calling 3G to H.323 or SIP endpoints. For calls between H.323 endpoints it is possible to set up 60 sessions between 768 and 192 kbit.
TMS Corporate Directory – the destination end point can be • selected via a search in a TMS phonebook.
Menu – the destination end point or service can be selected • via a menu.
Secure Access - support XML/SOAP over HTTPS, Web (HTTP) • encrypted password and the services that can be disabled.
Call rate of 64 kbit on ISDN side and 768 kbps on IP side for • each call is supported through the Entrypoint.
H.263 video compression. •
Interactive Video and voice Response (IVR). •
Default Entrypoint service when calling Border Controller IP • number

Support voice only calls (VoIP gatewaying) •
AMR, G.711 audio compression •
Support AMR bit rate 4.75 Kbit – 12.2 Kbit. •
Video IVR
Selecting IP endpoint from address book. •
Interoperability
Worldwide compatibility with standards-based • videoconferencing systems

Compatible with all available WCDMA H.324M video telephony • capable handsets supporting DTMF tones.

Connectors, Switches, Display, and Buttons

LCD panel Control buttons RS 232 interface LAN interface USB interface Power On/Off
To start the Entrypoint, simply connect the power cable, and press the power switch button at the back side to position 1.


On the front panel of the system the power indicator LED, marked Pwr, will turn GREEN.

1 PRI interface or 4 BRI interfaces depending on the configuration ordered,. VGA connector Power connector Power switch
indicator · Power switch

Configuring via the RS 232
The Entrypoint requires some basic configurations before it can be used. It will be necessary to find the IP-address and to create the dial-in and dial-out services to program the ISDN-PRI Line numbers.
Make sure the Entrypoint is Off and
Switch on the Entrypoint. Start a terminal program on the PC and
connect an RS232 cable between the Entrypoint and a PC.



To assign a static IP-address, type
Restart the Entrypoint. Start a WEB browser
and enter the IP-address of the Entrypoint. Default password: TANDBERG
Entrypoint for UMTS dial-in, enter PRI or BRI numbers and dial in number(s). For details, see Configuring the Entrypoint.
As an alternative to the configuration via RS 232 you may use the LCD panel to configure and check the IP settings, as well as to reboot the system. This is outlined on the next page.
To assign an IP Subnetmask, type Xconf ip address subnetmask
To assign an IP Gateway address, type Xconf ip address gateway
To configure the Entrypoint for IP dial in, register the Entrypoint to a Gatekeeper and enter
H.323 services. For details, see Configuring the Entrypoint
Power switch · To configure the

Configuring the IP Address via the Front Panel
The Entrypoint requires some basic configurations before it can be used. It is necessary to configure the IP-address and to create the dial-in and dial-out services to program the ISDN-PRI Line numbers.
Switch on and press any key to produce
Press ENTER to access the IP Settings
submenu. Use the UP/DOWN keys to select IP
the Main Menu. Use UP/DOWN to navigate to the IP Settings, if needed.
Address.
In addition to configure the IP address you
Press ENTER again to produce the
cursor. Use up/down keys to navigate
must also configure the default-gateway, netmask and set IP assignment to static.
between the digits of the number.
The LCD panel makes it possible to configure and check the IP settings as well as to reboot the system. The front panel LCD menu items are as follows:
Use ENTER to enter Digit Altering Mode. Use UP/DOWN to alter the digit value. Press ENTER as many times as needed
to move to the next digit to be altered and alter this digit.
IP Address IP Netmask IP Default GW
When finished editing use ESC to go to
the Confirm change menu. Use the UP/DOWN key to select yes or
no and ENTER to confirm. Use ESC key to navigate back to the
main menu.
DHCP assigned IP-addresses are supported by the TANDBERG Entrypoint (factory default).

As an alternative to the configuration via the LCD panel you may use RS 232 to configure and the system. This is treated on the previous page.
DOWN key ESC key



This section of the Entrypoint User Guide shows you how to gain access to the system, how to get an overview of ongoing calls, the menu operating principles, and how to dial from UMTS as well as from IP. Examples are provided for your convenience.

Accessing the Entrypoint
To start the Entrypoint, simply connect the power cable, and set the power switch button (both at the rear) to position I.
You may access the Entrypoint by entering the IP-address of the Entrypoint in a standard WEB-browser. You will then be asked to enter a password. You will need to enter admin as user name. The default password for the Entrypoint is TANDBERG. Remember that the password is case sensitive. Note that you may also use SSH and Telnet to configure the Entrypoint.



User name is admin
PASSWORD. Default password is TANDBERG (NB! case sensitive)
On the front panel of the system the power indicator LED, marked Pwr, will turn GREEN.

Reboot the Entrypoint.
You will be prompted for a new password.
Connect to the Entrypoint via the serial interface once it has
restarted.
The pwrec account is active for one minute following a restart. Beyond that time, the system will have to be restarted to change the password.
Login with User Name pwrec.
No password is required.
Power switch

The System Status windows of the Entrypoint can be accessed via the default URL: http://Entrypoint_IP_ Address/overview.
Service. Indicates the service type, i.e. DID, IVR, TMS phonebook, Menu.

Remote Number. This is the inbound number.

Duration. Duration of the call in hours, minutes and seconds.

Log out and Help. Click on the little key icon to log out and on the question mark to gain access to Help features.



Net. Indicates the net type, i.e. H.323, H.324m, SIP or Streaming.


Actions. Clicking on view details reveals both incoming and outgoing call leg information.
The Overview window presents information about all calls routed through the Entrypoint.
Clicking on a service call entry shows the service call details of the respective call, like e.g. inbound and outbound numbers – see the next page for more on this.
How to access the Management Menu System is described on the previous page.

The Service Call Details Window
The View Call Details tab presents information about all calls routed through the Entrypoint, i.e. inbound and outbound numbers, duration of the calls and call status – i.e. ringing (alerting), connecting and connected.
Incoming number. The service number, i.e. the number an external user dialed to get access to a portal service.



Service. Indicates the service name, i.e. DID, IVR, TMS Phonebook, Menu.

Duration. Indicates the duration of the call in hours, minutes and seconds.

Incoming. Indicates the information belonging to the call leg of the calling party.
Details. Remote numbers of the Incoming calls are the numbers of the calling party and remote numbers of the Outgoing calls are the numbers of the called party or service. Clicking View details reveals the Call Details, i.e. details belonging to the respective call leg.

Outgoing. Indicates the information belonging to the call leg of the called party/ service.
Status. Either alerting, connected or disconnected.
Remote Number. For inbound call legs it represents the number of the calling party, for outbound call legs it represents the number of the called party or service




Net. Indicates the net type, i.e. H.323, H.324m, SIP or Streaming.



Duration. Duration of this call leg in hours, minutes and seconds.
Incoming Number. Service number; can only be represented for inbound call legs.




To view the current status of the system, hover with the mouse pointer over Status to produce a drop-down menu as shown here. This section discusses the respective menu items.



Select PRI Status to access the PRI Status pane. ISDN/PRI Status (PRI Versions only)
The PRI status indication consist of 3 fields (see About the Rear Panel LED Operation below for PRI status):


Total number of channels – indicates the maximum available • number of simultaneous ISDN slots (calls) per port; typically 30 for an E1 PRI and 8 for an E1 BRI.
Number of free channels – indicates the number of free B- • channels on ISDN.
To view the ISDN PRI status, select the • ISDN status item of the Status tab.
In addition to the web page indications, the ISDN interface also contains 4 LEDs, located at the the Entrypoint rear panel.



Select ISDN/BRI Status to access the ISDN/BRI Status pane. ISDN/BRI Status (BRI Versions only)


BRI hardware status indication
The screenshot shows the status page of a BRI version of the Entrypoint. The BRI status displays the conditions of ISDN layer 1 and 2 separately. Green indicates up and in sync. Red indicates not in sync and indicate probably a disconnected ISDN line.

In some countries layer 2 can be down when there is no activity (ongoing connections).
However, layer 2 should become active once a call is made or received.
In case the BRI Entrypoint is connected with less than 4 BRI lines, the BRI interfaces with the highest number(s) should be left open. For example when only 2 ISDN lines are used they should be connected with interface 1 and 2.

H.323 Gatekeeper Status shows the current status of the Gatekeeper registration. To view H.323 gatekeeper status, as indicated in the screenshot shown here, select H.323 Status item of the Status tab.
Registration Status. If Registered, the Entrypoint is registered to the Gatekeeper with below mentioned Address and Port.



IP Address. Shows the IP address of the Gatekeeper.

Port. Shows the destination port number on the Gatekeeper.
In case the Entrypoint is in direct mode or in case the gatekeeper IP address is filled in incorrectly, the Entrypoint will not be registered with the Gatekeeper, and the Registration status is stated as Inactive.



Registration status will show Rejected when:
Gatekeeper unreachable; the Entrypoint’s • H.323 stack returns this reject message in case the gatekeeper is down.



Duplicate alias; a system with an identical • name has already been registered.
Authentication failure; Authentication • ID and/or Authentication Password are incorrect.

The default services, which come standard with an Entrypoint system, are:
IVR •

Entrypoint Service •



Select System Information to access the System Information pane.


This pane provides an overview of installed software and hardware.

To view available resources of the Entrypoint, open System Resources of the Status tab, as shown here.
This menu item shows the amount of active sessions, i.e. video and audio calls on this system. The system load percentage indicates the processor load.


These figures depend on the system’s use of resources. The use of Call Forwarding in dial plans reduces system load and therefore increases the number of simultaneous calls.

A System Load of 0 % indicates no load on the Entrypoint!




To configure the Entrypoint, hover with the mouse pointer over the System configuration to produce a drop-down menu. The drop-down menu consists of 6 items, i.e. ISDN, IP, H.323, SIP, SNMP and System, to configure respective system parts. Changing settings in the menus belonging to the ISDN, IP and System items only become effective after a system reboot, therefore these items all contain Restart buttons. Every configuration item is supported with a ? button for information about this specific item.

PRI Interface Configuration. Indicates the lowest numbered E1/T1 B-channel the system is allowed to use for each PRI-line when selecting channels for outgoing calls. Not in use in this version.
PRI Protocol. Select between the following PRI protocols:



Within ISDN different bearer capabilities are used to signal the type of data (Voice, Data, H320, H.324M), which is used by telephony switches and other equipment to determine how to handle data or calls (compressing voice data neglect etc). The outgoing bearer capability sets the ISDN bearer capability for the outgoing telephone (voice only) and video telephone calls.

Enable CRC-4. Used for most E1-PRI configurations. If your network equipment does not support this feature, switch off PRI CRC-4.
H.324M: • This ITU standardized capability is selected for outgoing calls by default.

UDI: • In some situations the switch does not accept calls which use the correct H.324M capability. This setting makes it possible to use the Entrypoint in these situations via selecting UDI.

Fractional line operation: Low Channel. Indicates the lowest numbered E1/ T1 B-channel the system is allowed to use for each PRI- line when selecting channels for outgoing calls. Presently, this setting has no effect.
Specifies the prefix, which has to be added • to National and International numbers, respectively.
The signalling specifies whether the • call is national or international. Since these prefixes are removed from inbound telephone numbers, the correct prefixes have to be added on call-backs.
These settings only apply if the Service providers network uses prefixes for national and international calls.
Save. When all settings are entered, click on Save to store the new settings.
All incoming calls are accepted independent of their bearer capabilities, consequently audio calls are accepted as well.
Outgoing Bearer capability

Select BRI to access the BRI Configuration pane.
BRI Protocol. Select between the following BRI protocols:


Save. When all settings are entered, click on Save to make the new settings become effective.



Outgoing Bearer capability. Within ISDN different bearer capabilities are used to signal the type of data (Voice, Data, H320, H.324M), which is used by telephony switches and other equipment to determine how to handle data or calls (compressing voice data neglect etc). The outgoing bearer capability sets the ISDN bearer capability for the outgoing telephone (voice only) and video telephone calls.
H.324M: This ITU standardized capability • is selected for outgoing calls by default.
You cannot configure ISDN BRI lines for special functions like dial out only! The Gateway will automatically select a free BRI line for H.323 to 3G calls and possibly block a DiD or an IVR menu when the BRI lines have different numbers. Consequently, we strongly recommend that all ISDN BRI lines have the same number range!
UDI: In some situations the switch does • not accept calls which use the correct H.324M capability. This setting makes it possible to use the Entrypoint in these situations via selecting UDI.
Contact your ISDN or telecom supplier about numbering plans of ISDN lines.
All incoming calls are accepted independent of their bearer capabilities, therefore audio calls are accepted as well.

Select IP from the Configuration to access the IP Configuration pane.
IP Address Assignment is DHCP or Static:

DHCP: • Dynamic Host Configuration Protocol can be selected when a DHCP server is present. Static IP Address, Static IP Subnet Mask and Static IP Gateway are ignored because these parameters are assigned by the DHCP server.

Up to five Domain Name Server IP addresses can be specified here. Your LAN administrator will provide the correct values for these fields. By default these fields are set to 127.0.0.1
Static: • If Static assignment is used, the Entrypoint’s IP address, IP subnet mask, and the Gateway’s IP address must be specified in the respective IP address fields.


IP Ethernet Speed provides five settings to choose from:


Auto • The Gateway will negotiate detect the speed and duplex on the LAN.


Date and Time Settings. An NTP server address can be specified here to provide the Entrypoint with up-to-date time and date information.

10Half • The Gateway will connect to the LAN using 10 Mbps/Half Duplex.
10Full • The Gateway will connect to the LAN using 10 Mbps/Full Duplex.

100Half • The Gateway will connect to the LAN using 100 Mbps/Half Duplex.
100Full • The Gateway will connect to the LAN using 100 Mbps/Full Duplex.
Save. When ready to store the new settings, press Save. These settings will take effect when the system has been restarted.
IP Address. The Static IP Address defines the network address of the Entrypoint. This address is only used in static mode. Your LAN administrator will provide you with the correct address for this field.

Restart. This button will restart the Entrypoint. Any changes made in the IP Configuration of the Entrypoint will take effect after the system has been restarted.
IP Subnet Mask. The Static IP Subnet Mask defines the type of network. Your LAN administrator will provide the correct value for this field.
IP Gateway. The Static Gateway IP address is set to 127.0.0.1 by default. In case of a router enter its address here. Your LAN administrator will provide the correct value for this field.
DNS Interface

Select H.323 to access the H.323 Configuration pane.
Mode. Enables the Entrypoint to register with a gatekeeper or leave it unregistered, i.e. in direct mode. Make sure that System Name is always set in direct mode. When registered with a gatekeeper, the H.323 Status shows Registered, the gatekeeper’s IP address and the Port used.


When registered with a gatekeeper, the H.323 Status shows Registered, the gatekeeper’s IP address and the Port used (see also Status, H.323 Status).
When the registration fails, the Registration status will be rejected. Three cases can be distinguished:
Gatekeeper unreachable • ; the Entrypoint’s H.323 stack returns this reject message in case the gatekeeper is down.
Duplicate alias • ; a system with an identical name has already been registered.
Dialling out from IP to IP or ISDN, through the Entrypoint, requires the use of H.323 numbers (E.164 aliases and service prefixes). This means that the Entrypoint must be registered to a gatekeeper; select the H.323 menu item in the Configuration menu.
Authentication failure • ; Authentication ID and/or Authentication Password are incorrect.


Selecting direct mode will result in no gatekeeper registration; hence it is not possible to dial through the Entrypoint via alias names. The H.323 Status shows Inactive.


IP Address. Enter the Gatekeeper IP address that the Entrypoint should register to. Leaving this empty will result in direct dialling without the use of aliases.

Save. When ready to store the new settings, press Save.
Authentication Mode is Off or Auto.
Off. • Register to the Gatekeeper without authentication.
In case password is not set/configured/inserted, the Entrypoint will still use the Authentication ID to register with the gatekeeper. However, when the Authentica- tion ID is left “unused”, the System Name field. will be used to register the Entrypoint with the gatekeeper instead. In case both the Authentication ID field and the System Name field are “unused” the Entrypoint can not be registered with the gatekeeper.
Auto. • Register to the Gatekeeper with H.235 authentication using ID/Password given below.
Authentication ID and Password. Enter the ID and pass- word required to perform H.235 authentication at the Gatekeeper. To register with a Gatekeeper that requires authentication, an NTP server has to be configured.
If the Gatekeeper is configured with an alternative Gatekeeper, the Status area may report a registration to the IP address of the alternative Gatekeeper.

Select SIP to access the SIP Configuration pane.


Enabled. Entrypoint will use this Proxy for call setup.


SIP proxy address. Enter the IP Address of the proxy server to which the Entrypoint will use for call setups.


Save. When ready to store the new settings, press Save. These settings will take effect when the system has been restarted.
SIP proxy port. Enter the port number belonging to that SIP proxy IP address.
Setting Mode to Off will not hide the SIP proxy address and port settings!
SIP settings

SNMP (Simple Network Management Protocol) is used for monitoring and configuring different units in a network. The Entrypoint’s SNMP Agent responds to requests from SNMP Managers (a PC program etc.). SNMP traps are generated by the agent to inform the manager about important events.
SNMP Mode. The SNMP operation modus can be set to:

Off • . Turns SNMP Off
ReadOnly • . Do not send SNMP information to the host
TrapsOnly • . Only send SNMP information identified as TRAPS to the host.


SNMP Community name. SNMP Community names are used to authenticate SNMP requests. SNMP requests must have this ‘password’ in order to receive a response from the SNMP agent in the Entrypoint.

Select SNMP to access the SNMP Configuration pane.



The SNMP Community name is case sensitive!
System contact. Used to identify the system contact via SNMP tools such as HPOpenView or TANDBERG Management Suite.

Location. Used to identify system location via SNMP tools such as HPOpenView or TANDBERG Management Suite.
Save. Press Save to activate new settings.
Host IP Address (1, 2 and 3). Identifies the IP-address of the SNMP manager. Up to three different SNMP Trap Hosts can be defined. Your LAN administrator should provide the correct values for these fields.

To configure the miscellaneous settings on the Entrypoint, select the System Configuration item.
Configuration. To change the system name of the Entrypoint, enter the new system name in the System Name field.




Services. The different IP services on the Entrypoint – Telnet, SSH, HTTP and HTTPS, can be disabled independently to prevent access to the system. Moreover, with Session Time Out, a maximum login time can be set.

External Manager settings. To enable cooperation between the Entrypoint and an external TANDBERG Management System (TMS) enter both its IP address and its path.
Save. When ready to store the new settings, press Save. These settings will take effect when the system has been restarted.

Restart. This button will restart the Entrypoint. Any changes made in the IP Configuration of the Entrypoint will take effect after the system has been restarted.




The Maintenance section describes how the system software can be upgraded, how new options can be made available via the installation of option keys, how the system password can be changed, and how the system is restarted.
& Upgrade

Under the Maintenance tab the system software can be upgraded, new options can be made available via the installation of option keys, the system password can be changed, and the system can be restarted.


Software Version. • Shows the currently installed Software version.
Hardware Serial Number. • This unique identifier number for the Entrypoint must be provided when ordering Software Upgrades and Option Keys.

The Entrypoint’s system software can be upgraded via the Upgrade item in the Maintenance menu. It also shows current software version and the Entrypoint’s hardware serial number. For new software versions a release key must be entered before the upgrade can be activated.
Release Key. Needed to upgrade a system to a new version. Dot releases do not require an option key.



To upgrade the Entrypoint, a valid Release key and Software file are required. However, for dot-release upgrades a Release Key won’t be needed.
To expand software options additional Option keys are required. Contact your TANDBERG representative for more details.
System Information · & Upgrade

Once you have entered the release key in the Release Key field


(see the previous page) and pressed Install Software a new win- dow will appear, which enables the entry of the software package, i.e. a .pkg, file to be uploaded For dot release upgrades a Release Key won’t be needed.
After the .pkg file has been selected, this will be uploaded


into the flash memory of the Entrypoint.
After the upload has been completed, this message is


shown.
This screen appears after clicking the Restart System


button.
& Upgrade

Password
Restart
To expand software options additional Option keys are required. Contact your TANDBERG representative for more details.







Add Option key. Enter the supplied option keys and press Add Option.
Key. Shows the option-key number.
Description. Shows the software function belonging to the key number.
Forgot the password? Use the following procedure to set a new password:
The Entrypoint can be restarted either via the Restart System menu item in the System configuration menu or via the Restart System buttons in the ISDN, IP, Misc and Upgrade System menus.
The pwrec account is only active for one minute following a restart. Beyond that time the system will have to be restarted again to change the password. New options take effect after the next restart only.
& Upgrade




Services

The Entrypoint is equipped with a number of persistent default services, i.e. services stored in the on-board non-volatile memory. Therefore, these services will always be available after a system restart. The following persistent default services can be distinguished:
Direct Inwards Dialling • (DID). Defines a one-on-one relation between an inbound and an outbound number.


Dial Extension • (IVR). Also known as Interactive Voice/Video Response (IVR), defines a relation between an inbound number and an interactive service, i.e. a menu, via which an outbound service can be connected to. The outbound service can be an audio or video service or an externally connected endpoint.
Menu Service • . A menu based call directory.
TMS Corporate Directory • (phone book). A connection with the installed TANDBERG Management System (TMS) phone book is setup. Via the phone book menu an outbound call to another endpoint, e.g. a 3G Mobile, H.323 or SIP endpoint, can be setup.
To view all service entries select the Service Configuration menu from the Service tab.
Services

To view all dialplan configuration entries or create a new dial plan select the Dialplan configuration menu item from the Services tab.
To view the dialplan entry details, click on the dialplan entry or on View/Edit of the respective dial plan. As has been discussed on the previous page four default services can be distinguished:


For each default service the dialplan setup will be illustrated with an example on the following pages.
Each dial plan has the following general fields, i.e. Dialplan entry details:
Enabled. • If the box is checked the service becomes available.
Name. • The name of the dial plan as represented in the Dialplan Configuration overview.
Net type. • Inbound call net type; either H.324m, H.323, SIP or All. All means that independent of the net type the call is accepted on a match with the predefined Prefix and Suffix.
Prefix. • Number to which the first part of the inbound number (bnr) is matched. The prefixis specified in the dial plan entry. The prefix is stripped from the inbound number.
Suffix. • Number to which the last part of the inbound number (bnr) is matched. The suffix is specified in the dial plan entry. The suffix is also stripped from the inbound number. The part of the number which remains after stripping both prefix and suffix is called remainder (See also the “useremainder” option in a DID service).
In the dialplan: When the Net Type is set to All make sure that the prefix and/or suffix is a valid H.323 prefix.
Setting it to All means that the prefix will be registered to the gatekeeper.
The H.323 registration will now fail, because”[email protected]” is not a valid H.323 prefix
Service. • Select one of the services as configured in the Services menu item (see the previous page for more on this).
Services

Use Remainder. Specifies whether a particular part, i.e. the remainder, of the inbound number will be used to form a part of the outbound number.
Suffix. Specifies the last part, i.e. the part appended to the remainder, of the Outbound number. The outbound suffix can be defined under Arguments.
Prefix. Specifies the first part, i.e. the part preceding the remainder, of the outbound number. The outbound prefix can be defined under Arguments.
No Media Sources can be added to DID service.
For a remainder to become non-zero a specified inbound Prefix has to match the first part and/ or a specified inbound Suffix has to match the last part of an inbound number, however individually or combinations of both never fully match the complete inbound number.
Net type. Either H.324m, H.323 or SIP of the outbound call.





AV mode. This mode determines the outbound audio and video call settings. It is either Audio Only, Audio + Video, Auto(matic) no fallback to audio, Auto + fallback to audio and Auto + always fallback to audio.
Both inbound Prefix and Suffix can be defined under Dialplan entry details. When Use Remainder, is active the previously mentioned “remainder” will be appended to and precede the Prefix and the Suffix of the outbound number, respectively. The outbound Prefix and Suffix precede and append, respectively, the “remainder” as to form the complete outbound number.

In the • Audio Only mode a voice call is being setup, even when all endpoints support both audio and video capabilities. Note that this setting will be overruled in case Allow Forwarding is set to Yes and both endpoints possess audio and video capabilities.
The latter prefix and suffix can be defined under Arguments. Prefixes and suffixes are standard parameters of dial plans.
In the • Audio + Video mode a call is only being setup when endpoints support both audio and video capabilities and a call with both these capabilities can be set up.
Suppose, as an example, in the Dialplan entry details the inbound Prefix equals 9876 and inbound suffix equals 54. In the Arguments settings the outbond prefix equals 1234. For an inbound connection to phone number 9876154 the Entrypoint will strip the prefix 9876 and the suffix 54 from the called number, hence the remainder equals 1. For the outbound connection the Entrypoint will add the prefix (configured in arguments) in front of the remainder, hence the outbound number equals 12341.
In the • Auto mode a call is being setup according to the capabilities of the endpoints. Of the latter, 3 versions can be distinguished: no fallback to audio, fallback to audio or always fallback to audio.

In the • no fallback to audio case either an audio + video or an audio only call is being setup, depending on the capabilities choice of the initiating endpoint, i.e. when an audio + video call is being set up, whereas the receiving endpoint only supports audio, the call is terminated.


For the same settings with an inbound number 9876254 results in an outbound number 12342. In case the prefix and/or suffix fully match the inbound number the remainder will be empty and the useremainder value will be ignored.
In the • fallback to audio case capabilities can be changed to an audio only call when the receiving endpoint supports only audio, even when an audio + video call is being set up by the initiating endpoint.
The • always fallback to audio case is used in case the telephony switch interferes or cannot handle capability renegotiation, therefore when an audio + video call fails automatically an audio call will be set up.
Allow forwarding must be switched off when using the Secretary functionality! The Secretary functionality will be discussed in the examples.
Allow forwarding. After call setup the call is offloaded from the Entrypoint system, i.e. not routed via the Entrypoint system any longer, to free resources.
Use sub number. The sub number is a number extension following the main number separated from the main number by an *. In this way a number plan behind a main number can be reached directly.
Services


Net type. Identical to DID service (see the previous page for details).


AV mode. Identical to DID service (see the previous page for details).

Prefix. Identical to DID service (see the previous page for details).



Suffix. Identical to DID service (see the previous page for details).


Allow forwarding. Identical to DID service (see the previous page for details).
Show DTMF Information Screen. This is a screen used within the service to draw the attention of the user to activate DTMF tones on its endpoint. This screen can be turned on (default value) or off.

Media Sources. Some of the default Media Sources, like the Welcome Screen and the DTMF Information Screen as mentioned under the Media Sources of this service, can be replaced by the user.

Services


Allow forwarding. Identical to DID service – see two pages back for details.


Entry [1 - 5]. For each of the five entries in the menu a number of three items can be configured:

Name. • Name of the service as depicted in the menu.
Service number. • The outbound call number dialled on selection of the respective menu item.
Media Sources. Some of the default Media Sources, like the Welcome Screen the DTMF Information Screen and the audio file belonging to the main menu, as mentioned under the Media Sources of this service, can be replaced by the user. Replacing the latter mentioned audio file enable the possibility to use the Menu service in audio only mode as well. The entries within a Menu service can also be used to link to another Menu service.

Services



TMS address. IP address of Tandberg Management System (TMS).

Allow forwarding. Identical to DID service – for details, see three pages back.

Show DTMF Information Screen. Identical to Dial Extension (IVR) service.

AV mode. Identical to DID service – for details, see three pages back.
Media Sources. Some of the default Media Sources, like the Welcome Screen, the DTMF Information Screen and the Please wait movie as mentioned under the Media Sources of this service, can be replaced by the user.

Services


Entry details: Enabled: Check Name: H.324m-H.323 Net Type: H.324m Prefix: 6789 Suffix: Service: Direct Inwards Dialling Arguments: Net Type: H.323 A V Mode: Auto + fallback to audio Prefix: 5 Suffix: Use Remainder: Yes Allow Forwarding: No
Given the supported net types, H.324m, H.323 and SIP, 9 unique inbound and outbound net type combinations for both DID and IVR dial plans can be defined Some of these combinations will be discussed in a few examples.
When dialling the number 67890000 there will be a match with “0000” as the remaining number. The H.323 number that will be connected to will be: 50000 (construction: Prefix + Use remainder number). When dialling number 67894321 this will match with “4321” as the remaining number. The H.323 number to call will be: 54321. In this way a range of ISDN numbers can be mapped onto for instance a range of H.323 numbers.
Dial Plan Examples




The TMS Corporate Directory service allows one Endpoint, i.e. a UMTS phone, H323 or SIP, to dial another Endpoint directly, without knowing or having to (manually) enter the extension number via DTMF.
TMS Corporate Directory is a menu based dial-in method, which combines a directory listing from TMS with IVR. In this mode the user can search in the global address book provided via TMS using the alphanumeric part of the keypad.
The TMS Corporate Directory service searches and displays entries matching the user input string. A maximum of 6 entries per page are displayed.
One can browse back and forth through the pages by pressing the * button or the # button, respectively. With the 0 button one can go back to a previous stage in the service or even back to the previous service when the phone book is entered via the entry point or dial extension service.




A menu option is available when text is present next to the respective button. In case access to multiple phone books is available, the user can select one in the first stage. In the second stage, either a search string can be entered by the user, or one can use DTMF to search alphabetically.
All names matching the search string will be displayed up to a maximum of 10 pages, where each page contains a maximum of 6 names. Pressing the # button will commence the search. Entering an empty search string, i.e. pressing the # button without entering any character, will show a two-stage alphabetical menu structure providing the first letter of the search string only.


In the third stage one of the matched names can be selected by pressing the number preceding the name. When multiple numbers are provided with the selected name one can select the number of choice and the dialling of the outbound number will be commenced immediately.
If the above left search field is left empty and Search (lower right corner) is clicked on, the alphabetical search as shown to the right will be displayed.
Dial Plan Examples


Philip Pedersens vei 20, 1366 Lysaker, Norway
1212 Avenue of the Americas, 24th Floor, New York, NY 10036
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.