A. Installation Environment In order to ensure the safety with the DVR product and maximize product per- formance, please notice the following while/ before you install the product:
i. Only use with AV220V voltage supply, please check with the power supply with correct voltage before installation. DO NOT USE WITH ANY OTHER ADAPTER (DO NOT PLUG INTO AC380V HIGH VOLTAGE SUPPLY!) ii. Away from a humid place or exposure with rain. iii. DVR should be installin in a horizontal position. iv. Avoid placing the DVR in a location where electric conductivity is high. v. Avoid exposure to direct sunlight for prolinged periods and do not store in
areas with extreme temperature conditions. vi. For the heat transfer and ventilation purposes, locate the DVR at least 15cm
from another object (such as awall) while installing the device. vii. Avoid placing the DVR near any chemical product. Accidental contact
may harm the device. viii.Avoid placing the device in areas that are dusty and unkept. Dust may
damage the unit. ix. Use correct grounding for the DVR device while operating.
i. Do not operate the device with wet hands. ii. Keep away from any wet place, fire hazard can occur by short circuit damage by any liquid dropped to device. iii. Do not place anything on the top of device; iv. Use a clean cloth to clean the device. Do not use chemicals to clean the
device. v. Live voltage does exist while the device is connected to a power supply,
even when the device is not turned on. vi. Disconnect the DVR when not in use for an extended period.
This device had been certified with the international safety standard.



3. Playback function Key Definition [Playback] Playback function activate [Slow] Playback with slow motion with speed at 1/2x, 1/4x, 1/8x,
resume at normal speed with [Playback]pressed [Pause /Play] Pause video while press once, frame-to-frame at re-press. [Playback] Key for resume to normal [Fast Forward] 2x, 4x Speed available, Playback Key for resume at reg. play [Fast Backward] 2x, 4x Speed available, Playback Key for resume at reg. play [Recording] Available for 4 channels recording, single online monitor
system can play with manual recording. [Stop] Stop manual recording
For non-menu screen, 1, 2, 3 and 4 represent for the video channel 1, 2, 3 and 4 respectively [Zoom In +], [Zoom Out -] Zooming adjustment [Brightness +], [Brightness -] Brightness adjustment [Focus +], [Focus -] Image Sharpness adjustment [Auto] Auto Mode activate [Manual] Manual Adjustment Platform [Default] Use with Default configuration [Window Wiper/Lighting] Control with window rain wiper and lighting

5. Other options Key Definition [Power ON /Power Off] System turn on and off(Stand-by and start) [Login/Locked]Key Login to enter to operate mode with require password and
lock current setting activation [Status] Checking with record information store inside of hard drive. [Display Swap] Swapping between multi-channel and single channel
monitor system [Channel Config] Channel configuration [Adjustment] Display with the setting of brightness, colour, contrast,
motion detect sensitivity, adjust with[+], [-] [Return] Return back to operating screen from setup menu [CF Card] While CF card inserted, this button can activate for the
CF function, for more details please refer with your CF Card operation instruction manual [Language] English, Simplified Chinese, Tradition Chinese selectable [Network] Network parameter setting [Record] For 4 channels monitor system. Can activate 4 manual
records or for single channels the monitor system can activate 1 manual record [Stop] Stop manual recording [Setting] Setting with system configuration and parameters [F1] Time select while in Playback mode [F2] For single channel system, control menu activation while
this key being pressed. While left/right, up/down key pressed, adjusted with station recorder left/right, up/down direction movement,press[ENTER]return to original position. [Zoom In +], [Zoom Out -] Zooming adjustment [Brightness +], [Brightness -] Brightness adjustment [Focus +], [Focus -] Image Sharpness adjustment [Auto] Auto Mode activate [Manual] Manual Adjustment Platform [Default] Use with Default configuration [Window Wiper/Lighting] Control with window rain wiper and lighting
Control menu quit with re-press[F2] [F3] No specific function set for this key
[can be reserve for other function] [F4] While in monitor system, swap with BNC / VGA output


1 Ventilation fan 2 AC220V power in 3 Power switch 4 Alert signal in/out/ RS-485: 4 channels input/ output 5 Audio input: provide 4 channels audio input 6 Audio output: 2 channels for audio out, left side for replay output, right side for the surveillance output 7 Video output: 2 channels for video signal output, channel 1 for surveillance output, channel 2 for mixed video output 8 Video input: Channel 1~4 for video signal input 9 VGA: output with external computer monitor, only for Playback screen or on time recording screen, not for surveillance review
Method: Press[F2]in remote control after key in password, then switch the screen from display output with monitor screen 10 RS-232: Standard RS-232 connection 11 Ventilation fan for main unit

PIN DEF FUNCTION PIN DEF FUNCTION 1 IN0 Channel 1 Alarm input 16 4COM Channel 2 Alarm output 2 IN1 Channel 2 Alarm input 17 4NO 3 IN2 Channel 3 Alarm input 18 4NC 4 IN3 Channel 4 Alarm input 19 COM 5 IN4 NC 20 NO 6 IN5 NC 21 NC Power fault report output 7 IN6 NC 22 COM 8 IN7 NC 23 NO 9 OUT0 Channel 3 Alarm output 24 NC Fault report output 10 OUT1 Channel 4 Alarm output 25 485A 485A 11 OUT2 26 485B 485B 12 OUT3 27-38 . .GND Ground 13 3COM Channel 1 Alarm output 39-44 . .+12V +12V 14 3NO 15 3NC
2, 4 channels alert layout definition 1-2 channels for open socket switch output, no need for additional alarm driver. 3-4 channels for power levels output(OUT for low power out), require additional alarm drive add in here.


3. Platform Control Key Key Definition [Zoom In +], [Zoom Out -] Zooming adjustment [Brightness +], [Brightness -] Brightness adjustment [Focus +], [Focus -] Image Sharpness adjustment [Auto] Auto Mode activate [Manual] Manual Adjustment Platform [Default] Use with Default configuration [Window Wiper/Lighting] Control with window rain wiper and lighting
4. Playback function Key Definition [Playback] Playback function activate [Slow] Playback with slow motion with speed
at 1/2X, 1/4X, 1/8X, resume at normal speed with [Playback] pressed [Pause /Play] Pause video while press once,
frame-to-frame at re-press. [Playback] Key for resume to normal [Fast Forward] X2, X4 Speed available, [Playback] Key
for resume at normal play. [Fast Backward] X2, X4 Speed available, [Playback] Key
for resume at normal play.


(Stand-by and start) [Login /Locked]Key Login to enter to operate mode with
require password and lock current setting activate [Status] Checking with record information store
inside of hard drive [Display Swap] Swapping between multi-channel and
single channel monitor system [Channel Config] Channel configuration [Adjustment] Display with the setting of brightness,
colour, contrast, motion detect sensitivity, adjust with [+], [-] [Return] Return back to operating screen from
setup menu [CF Card] While CF card inserted, this button can
activate for the CF function, details please refer with CF Card operation instruction [Language] English, Simplified Chinese, Tradition
Chinese selectable [Network] Network parameter setting [Record] For 4 channels monitor system, can
activate 4 manual record, or for single channels monitor system, can activate 1 manual record [Stop] Stop manual recording [Setting] Setting with system configuration
and parameters [F1] Time select while Playback mode [F2] For single channel system, control menu
activate while this key being pressed While left/right, up/down key pressed, adjusted with station recorder left/right, up/down direction movement, press[ENTER]return to original position [Zoom In +], [Zoom Out -] Zooming adjustment [Brightness +], [Brightness -] Brightness adjustment [Focus +], [Focus -] Image Sharpness adjustment [Auto] Auto Mode activate [Manual] Manual Adjustment Platform [Default] Use with Default configuration [Window Wiper/Lighting] Control with window rain wiper and lighting
Control menu quit with re-press [F2] [F3] No specific function set for this key
[can be reserve for other function] [F4] While in monitor system, swap with BNC / VGA output

The system will be in standby mode. Press the [ON/OFF]button in front panel or remote control, the red light will turn off, then the monitor will be activated to show as 4-channel windows status. There will be channel numbers shown to indicate each input signal. Also, the top of screen will show the system time, number of hard disk and CF card status (if applicable) shown in the center of the screen (there would be an alert warning for no hard-disk installed), all of the information will be shown on the screen for 5~6 seconds. There will be a count down from 100 to 0 seconds (shown in red color font). The system will be locked up after the count down reaches 0 seconds. Notice: If the device is being set for timer record function, there is no need for standby status after the system turns on, the system will go to multi-channel screen.
2. System Login While the system is in lock-in status, press the [Login/Logoff] button in the front panel or remote control, then the screen will have pop-up window appear stating "Unit ID: *****, Unit ID : 000". Select the desired unit ID. "Password required: " then key in your login password to enter into the system (The DVR will accept User password or Administrator password). 1. After the user password is keyed in correctly, the message "USER PASSWORD CORRECT" will be shown. Then the user can enter into restricted functional/feature level functions with the device. (default password is : 00000000) 2. After the Administrator password is keyed in correctly a message "ADMIN PASSWORD CORRECT" will appear, then the administrator can enter into all functional/feature levels with the device. (default password is : 88888888)
1. User can only playback all existing files, however, they can not stop the recording, or access record setup. While the administrator can access all setup features. 2. After the password key in correctly, the count down timing (shown in top right corner) will change from red to green color, this indicates that the user can access different operations. There will be a 100 seconds operation time allowance after each key-in button is pressed before system locked. The user will be required to re- enter their password to returnto normal operation level once the "LOCK" indicator shown in top right corner; 3. The user must key-in unit ID and password to enter into the operation system while in LOCK status.
Remark: Please make sure the system status is in standby mode before powering off. Please do not power off the machine while it is in recording or playback system setting.

A. Menu Setup While system is powered up, select [General Setting] to alter the system setup. The setup menu can be seen below, highlight the item for selection and then press [Enter] to confirm. (while system recording, not allow to change any setting for current channel)
GENERAL SETTINGS Record Settings Timer Record Motion Detection Alarm Record Channels Housings Network Language Exit
A-1 General Parameter Setting: Highlight and select "General Settings", then press [Enter] for this selection, the sub-menu will shown (as below), then select the desired area.
GENERAL SETTINGS Date / Time: 2003-05-08-23:59:00 Saturday Unit ID: Location: HDD Overwrite: Yes System: PAL NTSC Admin_pwd_modify Operate_pwd_modify HDD Format Restore Default Setting Return
Date/ Time: Highlight and press [Enter] to confirm for change for date and time, range will apply following:
allow recording continuously even if the hard disk space fulls up. The video will be recording into FIFO (First-In-First-Out) format. When OFF is selected, the recording function will stop once the HDD has filled up. System: Select one of two options: "PAL" and "NTSC", then press [Enter] to confirm. NTSC is
the standard for North American video systems while PAL is standard for European recording systems. Admin_pwd_modify: Allows the you to change the administrator password, press[Enter] to
enter this function. It will require you to key-in the new password twice to confirm the new password (this option only available with the administrator authorization level). Operate_pwd_modify: Allows the you to change the operator password, press[Enter] to
enter this function. Require the user to key-in the new password twice to confirm. HDD Format: This will allow you to format the hard disk drive while non-recording status,
while this option being selected, select with [START] and press [Enter] to confirm this function. Restore Default Setting: Restore all the settings to the factory level settings. A confirmation
option will appear to reconfirm system restore. A sample chart is shown on the next page. Return: Go back to previous menu.
![Page 11 of the SVAT Electronics CVDVR900 user manual — to select and press [Enter] to confirm this function:](/cdn/reader/ff/ffcaf7381c760aaebb1f1ce410ad35fe6c23b9c71fa9bf1629b28bdb1926ddf4/images/page-11.webp?w=400)
Record Settings Channel Quality Definition Frame Mode 1 14 CIF 25 CBR 2 02 CIF 25 CBR 3 03 CIF 25 CBR 4 04 CIF 25 CBR HDD Store Mode Centralize Individual Compound Return
GENERAL SETTINGS Record Settings Timer Record Motion Detection Alarm Record Channels Housings Network Language Exit
Record Settings Channel Quality Definition Frame Mode 1 14 CIF 25 VBR 2 02 D1 12 CBR 3 03 HD1 6 VBR 4 04 D1 3 VBR HDD Store Mode Centralize Individual Compound Return
"X" to the left of a channel, recording is not allowed. Pressing [Enter] will enable the channel. HDD Format: This will allow you to format the hard disk drive while in non-recording status.
Select [START]and press[Enter] to confirm this function. Image Quality: From 1 to 8 levels, 1 is the best quality. Use the cursor to select and press
[Enter] to confirm this function, with [+]and [-]to move the level. Definition/Sharpness: From "D1, HD1, CIF" 3 difference levels. Using the cursor to select and
D1: DVD picture sharpness quality; HD1: SVCD picture sharpness quality; CIF: VCD picture sharpness quality; Frame Rate: While in PAL video system choose from "25, 12, 06, 03, 01, 0.5" frame rate levels.
While in NTSC video system, choose from "30, 15, 08, 04, 02, 01" 6 difference frame rate levels. Using the cursor to select and press [Enter] to confirm this function, and with [+]and [-]to move the level. PAL video system:
D1: Provided with totally 25 frame/ second in 4 channels; HD1: Provided with totally 50 frame/ second in 4 channels; CIF: Provided with totally 100 frame/ second in 4 channels; NTSC video system:
D1: Provided with totally 30 frame/ second in 4 channels; HD1: Provided with totally 60 frame/ second in 4 channels; CIF: Provided with totally 120 frame/ second in 4 channels; Mode: "VBR, CBR" are the 2 different encoding methods available in here. Using the cursor

Image Quality (Encode Rate Kbit/Second)
1 2 3 4 5 6 7 8
D1 Fixed 2400 2200 2000 1800 1600 1200 1000 800
HD1 Fixed 1200 1100 1000 900 800 600 500 400 CIF Fixed 900 800 700 600 500 400 300 200
MAX 2400 2200 2000 1800 1600 1200 1000 800
MIN 2000 1800 1400 1200 1000 800 600 400
HD1
MAX 1200 1100 1000 900 800 600 500 400
MIN 900 800 700 600 500 400 300 200
MAX 900 800 700 600 500 400 300 200
MIN 600 600 500 400 300 200 200 100
HDD Store Mode: "Centralize, Individual, Compound" are 3 different hard disk storing modes available in here. Using the cursor to select and press [Enter] to confirm this function:
Return: Using the cursor to select and press [Enter] to confirm back to main menu.
A-3 Timer Record Setting: Highlight and select "Timer Record", then press [Enter]for this selection, the sub-menu will shown (as below).
GENERAL SETTINGS Record Settings Timer Record Motion Detection Alarm Record Channels Housings Network Language Exit
Ch Timer Motion_Mode 1 On Off On Off 2 On Off On Off 3 On Off On Off 4 On Off On Off
Timer Record: "On, Off" are the 2 different status settings. Use the cursor to select and press [Enter] to confirm this function. While timer selected, there will be 16 different setting tasks for timer setup in each channel (8 different day types, and 2 different period settings avail- able for each type):
Channel 1 Timer Record Settings Date Period 1 Period 2 Everyday 08:00-12:00 14:00-18:00 Mon 08:00-12:00 14:00-18:00 Tue 08:00-12:00 14:00-18:00 Wed 08:00-12:00 14:00-18:00 Thurs 08:00-12:00 14:00-18:00 Fri 08:00-12:00 14:00-18:00 Sat 08:00-12:00 14:00-18:00 Peak 08:00-12:00 14:00-18:00 Return
Sharpness · Encode Method · Timer Record Settings

Motion Mode: "On, Off" are the 2 different status settings to enable and disable this func- tion respectively. Using the cursor to select and press [Enter] to confirm this function.
A-4 Motion Detection Setting: Highlight and select Motion Detection, then press [Enter] for this selection, the sub-menu will shown (as below), then select the required area.
GENERAL SETTINGS Record Settings Timer Record Motion Detection Alarm Record Channels Housings Network Language Exit
Motion Detection Channel Effective Alarm Region
1 Settings On 2 Settings On 3 Settings Off 4 Settings Off
Effective Region: Use the cursor to select Settings and press [Enter] to confirm this function. Then there will be a region setting screen with full of square grid (as picture shown below), press [Setting] to get the detect area as full screen (all the grid squares will turn a light green square as selected) re-press [Setting] to cancel the selected areas (all grid squares will turn back to clear, and there will be purple flashing cursor right in the centre of screen for selection).
Return

A-5 Alarm Record Setting: Highlight and select Alarm Record, then press [Enter] for this selection, the sub-menu will shown (as below), then select the required area.
GENERAL SETTINGS Record Settings Timer Record Motion Detection Alarm Record Channels Housings Network Language Exit
Ch Alarm In_Mode 1 On Close Alarm_Delay: 005s 2 Off Open Out_Delay: 005s 3 On Open Keep_Delay: 005s 4 Off Open Multi_Ch_Rec: On Multi_Ch_Output: On Return
and press [Enter] to confirm this function. While "On" is selected, there will be 16 different task settings for timer setup in each channel (8 different day types, and 2 different period settings available for each type):
Channel 1 Alarm Record Settings Date Period 1 Period 2 Everyday 08:00-12:00 14:00-18:00 Mon 08:00-12:00 14:00-18:00 Tue 08:00-12:00 14:00-18:00 Wed 08:00-12:00 14:00-18:00 Thurs 08:00-12:00 14:00-18:00 Fri 08:00-12:00 14:00-18:00 Sat 08:00-12:00 14:00-18:00 Peak 08:00-12:00 14:00-18:00 Return
alarm system is set to the "Close" option, when open signal starts, the alarm signal is produced. The input mode in here should be set as "Open". Alarm_Delay: Key in the number key to setup the time delay (range from 0 to 300 seconds)
for alarm recording (default setting as 10 seconds). Out_Delay: Key in the number key to setup the time delay (range from 0 to 300 seconds)
for alarm output (default setting as 10 seconds). Keep_Delay: Key in the number key to setup time delay (range from 0 to 300 seconds) for
alarm warning signal (default setting as 10 seconds).
For example: If an alarm is produced at 23:30:50 the device should start the recording from time 23:30:40 since the system per-recording time was set as 10 seconds. The system will release the alarm warning signal. Whole recording depends on the alarm time, per-recording alarm time and alarm warning signal to perform recording
Multi_Ch_Rec: "On, Off" are the 2 different status settings available. Use the cursor to select and press [Enter] to confirm this function. While "On" is selected, there will be 4 multiple channels interface display as shown below:
Alarm Record Settings

Multi_Ch_Rec: "On, Off" are the 2 different status settings available. Use the cursor to select and press [Enter] to confirm this function. While "On" is selected, there will be 4 multiple channels interface display as shown below:
Ch Alarm In_Mode 1 On Close Alarm_Delay: 005s 2 Off Open Out_Delay: 005s 3 On Open Keep_Delay: 005s 4 Off Open Multi_Ch_Rec: On Multi_Ch_Output: On Return
1 2 3 4 5 6 7 8
Multi_Ch_Output: "On, Off" 2 difference status setting. Using the cursor to select and press [Enter] to confirm this function. While "On" selected, there will be 4 multiple channels inter- face display as shown above.
A-6 Channel Setting: Highlight and select Channels, then press [Enter]for this selection, the sub-menu will shown (as below), then select the required area.
GENERAL SETTINGS Record Settings Timer Record Motion Detection Alarm Record Channels Housings Network Language Exit
Channel Title Cover Time Insert 1 Warehouse Yes Yes 2 Cash No No 3 Cash 2 No No 4 Main Desk No No

[Enter] to confirm this function. While "On" selected, a system clock will be shown while recording.
A-7 Housing Setting: Highlight and select Housings, then press [Enter]for the selection, the sub-menu will shown (as below), then select the required area.
GENERAL SETTINGS Record Settings Timer Record Motion Detection Alarm Record Channels Housings Network Language Exit
Channel Protocol BaudRate No. 1 pelco-d 1200 01 2 pelco-p 2400 10 3 enkel 4800 25 4 ccr-20g 9600 63
(01~63).
A-8 Network Setting: Highlight and select Network, then press [Enter] for this selection, the sub-menu will be shown (as below), then select the required area.
GENERAL SETTINGS Record Settings Timer Record Motion Detection Alarm Record Channels Housings Network Language Exit
A-9 Language Setting: Make sure that English is the default setting.

A-10 Exit: Highlight and select Exit, then press [Enter] to confirm for save the change of setting then return back to main menu.
B. Info Menu While system is in use, select [Info Menu] to check the menu content. The info menu can be seen as shown below, highlight the item for selection and then press [Enter]to confirm.
All Record Alarm Record Alarm Log Operate Log Channel Status HDD Status Machine Info Exit
B-1 All Record: Highlight and select All Record, then press [Enter]for this selection, the sub-menu will shown (as below), then select the required channel and date, press "Start" to see the record at specific requirement.
Input date and time of all record
All Record Alarm Record Alarm Log Operate Log Channel Status HDD Status Machine Info Exit
After pressing enter, there will be a sub-menu shown (as below), and the calendar will dis- play dates 1 to 31 as per selected month, move the cursor to select different dates in order to check the record and press [Enter] to view. A yellow font represents recording existance for this. If no recording exists for certain date, "No exist record" will be displayed. Using page up ("UP") and down ('DO") ("+/-" key) for those more than 1 page recording list.
Channel 1 2003/11/28 Recording Info 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 UP DO CASH 1 08:30-09:00 R CIF 25 CASH 2 09:30-10:00 M CIF 25 FRONT 11:30-12:00 A CIF 25 CASH 1 17:00-18:00 R CIF 25
Channel 1 2003/11/2 9 Recording Info 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 UP DO NO EXIST RECORD
Info Menu · Info Menu

Press [Enter] to see the recording video/audio signal, press [F1]for time select playback, and press [SLOW] for slow motion playback at a different speed. Press [FF]for fast forward playback and [FB]for fast backward playback, press [PAUSE] key to pause the video. [RETURN] to exit the playback window and back to main menu.
B-2 Alarm Record: Highlight and select Alarm Record, then press [Enter] for this selection, the sub-menu will be displayed (as below. Then select the required channel and date, press "Start" to see the record at a specific requirement.
Input date and time of alarm record
All Record Alarm Record Alarm Log Operate Log Channel Status HDD Status Machine Info Exit
After pressing Start there will be a sub-menu shown (as below), and the calendar will dis- play as well from date 1 to 31 at the selected month. Move the cursor to select different dates to check the record and press [Enter] to see. The dates shown in a yellow font are dates where there has been an alarm record.
When no recording exists for a certain date, "No exist record" will be displayed. Using page up ("UP") and down ('DO") ("+/-" key) for dates when more than 1 page recording list is available. Press [Enter] to see the recording video/audio signal. Press [F1] for time select playback, press [SLOW] for slow motion playback at different speeds. Press [FF] for fast forward play- back and [FB] for fast backward playback, with [PAUSE] key to make the frame pause. Press [RETURN] to exit the playback window and back to main menu.
Channel 1 2003/11/28 Recording Info 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 UP DO
Channel 1 2003/11/28 Recording Info 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 UP DO
CASH 1 08:30-09:00 R CIF 25 CASH 2 09:30-10:00 M CIF 25 FRONT 11:30-12:00 A CIF 25 CASH 1 17:00-18:00 R CIF 25 WAREH 20:10-21:10 R CIF 25
RETURN
RETURN
Info Menu

B-3 Alarm Log: Highlight and select Alarm Log, then press [Enter] for this selection, the sub-menu will be shown (as below), this allows you to see the recent alarm status and report.
All Record Alarm Record Alarm Log Operate Log Channel Status HDD Status Machine Info
2003/11/28, 23:30 Alarm at :1
Return Page Up Page Down First Page
B-4 Operate Log: Highlight and select Operate Log, then press [Enter] for this selection, the sub-menu will be shown (as below), this allow to show the recent operate status and report.
All Record Alarm Record Alarm Log Operate Log Channel Status HDD Status Machine Info
2003/11/28, 23:30 Parameter Change
Return Page Up Page Down First Page
B-5 Channel Status: Highlight and select Channel Status, then press [Enter] for this selection, the sub-menu will be shown (as below), this allows to show the 4 channel’s status, including image quality, sharpness, frame rate.
All Record Alarm Record Alarm Log Operate Log Channel Status HDD Status Machine Info
Motion Ch Status Q Size Frames Alarm Detection 1 Record 2 D1 25 Alarm Close 2 Idle 2 D1 25 Alarm Close 3 Record 2 D1 25 Alarm Close 4 Record 2 D1 25 Alarm Close
B-6 HDD Status: Highlight and select HDD Status, then press [Enter] for this selection, the sub-menu will be shown (as below), this allow you to view the hard disk status for 4 channels, including total hard disk space and available space.
All Record Alarm Record Alarm Log Operate Log Channel Status HDD Status Machine Info
HDD Status Capacity Free_Space 1 Work 040GB 012,000MB 2 None 000GB 000,000MB 3 Work 000GB 000,000MB 4 Record 000GB 000,000MB

B-7 Machine Info: Highlight and select Machine Info, then press [Enter] for this selection, the sub-menu will be shown (as below), this allow to show all the machine ID number and software version.
All Record Alarm Record Alarm Log Operate Log Channel Status HDD Status Machine Info
Unit ID.: 43743746194619463289573296 Version:
B-8 Exit: Highlight and select Exit, then press [Enter] to confirm for save the change of setting then return back to main menu.

C-1 Compact Flash Card Upgrade: 1. Using a PC to make sure your Compact Flash card formated into FAT32 format. (if not already in the FAT32 format). 2. Insert the Compact Flash card into the DVR CF Slot while the DVR is turned off. 3. Press [ON/OFF] button without release to switch on the power; 4. Within 2~3 seconds the LED light (SYS and POWER) should be flashing and that means that the upgrading is in progress. 5. Upgrading will take approx. 1 minute and both LEDs will turn off once upgrading has completed. 6. Turn off the device and then remove the Compact Flash card from the slot. 7. Restart the device and the new software should be installed.
C-2 Compact Flash Card Backup: In order to copy the data from hard disk into the Compact Flash card, please follow the following procedures:
C-3 Playback Compact Flash Card Content: In order to playback the data from the Compact Flash card, press [CF card] to enter the Compact Flash card menu and use the cursor to select operation:
C-3-1 Compact Flash card management: Highlight and select CF Manage, then press [Enter] for this selection, the sub-menu will be shown (as seen below), this allows you to view all the information of the current CF card.
CF Card Manage Copy Information Renew setting
Previous Page Next Page Delete Help: Press Enter to playback, press right key button then Enter to delete

CF Card Manage Copy Information Renew setting
XXXX 09:15-09-16 M CIF 25 XXXX 10:10-10:12 M CIF 25
Previous Page Next Page Delete Help: Press Enter to playback, press right key button then Enter to delete
C-3-2 Copy Information: Highlight and select Copy Information, then press [Enter] for this selection, the sub-menu will be shown (as below):
CF Card Manage Copy Information Renew setting
CF Card Manage Copy Information Renew setting
Copy in progress
C-3-3 Renew setting: Highlight and select Renew setting, then press [Enter] for this selection, the sub-menu will be shown (as below):
CF Card Manage Copy Information Renew setting
Renew in progress...


Manual Recording: 1. Use the [Record] button to start recording, will be a red dot on the top right side corner of the monitor which indicates the recording is in progress. 2. Press the [Stop] button to stop the recording and the red dot will turn off.
Timer Recording: Refer to section A-3 Remark: The Channel 1 timer setting has the "Peak" time setting (from number 16 option), the peak setting is not available for other channel. After the "Peak" had been selected, the device will not have any stand-by mode while no setting required.
Alarm Recording: Refer to section A-4 Remark: When the device is in stand-by mode, there would be a 15~20 second time delay when the alarm recording activates and recording starts.
Playback all record: Refer to section C-1
Playback Alarm record: Refer to section C-2
1. Use the [Stop] button to stop the playback;
D-5 Slow Playback:



Item Device Parameter Specification / Details
UI Language English/ Simplified Chinese/ Traditional Chinese
User Interface Icon operation interface (OSD menu)
Security User level passw ord, administer level passw ord
Video Input 4 independent input w ith 1.0Vp-p, 75Ù BNC
Video Output 1 PAL/NTSC output w ith 1.0Vp-p, 75Ù BNC, composite video
1 VGA output Video Display 1 channel and 4 channels w ith difference display mode
NTSC: 30 frames per second CCIR525 lines 60 Hz System Resource Real time recording w ith 1 channel playback and 4 channels monitoring Online real time monitor Audio Input 4 channels independent input, L, R Channels 600Ù RCA Audio Output 1 channel from monitor mode, 1 channel from playback mode 600Ù RCA Basic output 1.0—2.2V S/N ?-30dB Recording Format Video and sound at same time Compression PCM Encoding MPEG-4 Variable encode rate \ Fixed encode rate
Image Format CIF( 352×288 pixels) 1/2D1( 704×288 pixels) D1( 704×576 pixels)
Video Standard ISO14496 Audio Standard PCM
Video Freq. 12.5K-112.5Kbyte/s 25K-150Kbyte/s 50K-300Kbyte/s
Audio Freq. 8Kbyte/s Audio Size Rate 28.8Mbyte/hour Video Size Rate 45M-405Mbyte/hour 90M-540Mbyte/hour 180M-1080Mbyte/hour Storage 4 IDE hard disk, support 200G or larger hard disk size Image Quality 8 Adjustable levels Max Frame Rate 25 frames/ sec/ channel 12.5 frames/ sec/ channel 6.25 frames/ sec/ channel Resolution Playback 352×288 pixels, Playback 704×288 pixels, Playback 704×576 pixels, Real time 704×576 pixels, Real time 704×576 pixels, Real time704×576 pixels, VGA output 720×576 pixels VGA output 720×576 pixels VGA output 720×576 pixels Data capture Bi-directional Motion Detect Independent setting with each channel, with 192 detect region for each channel and adjustable motion sensitivity
Digital Processing and Storing
Input 4 independent input channels Output 4 independent alarm output ( 2 voltage output, 2 open sw itch w ith output at 12VDC, 500MA) Alarm mode Open / Short Serial Port RS485, extendable w ith external modem Serial Port RS232, common serial port
Netw ork port RJ-45 10M/100M boardband port
Internet Protocol Support TCP/IP, UDP/IP
Transfer mode Dial-up, ADSL, ISDN, internet, intranet
Brow er IE brow er


Pow er AC 220V±20%, 50Hz±2%
Consumption 15W( excluding w ith hard disk)
Outer Dimension 2U Standard device box 440( W) ×90( H) ×420( D) mm
Weight 5.5KG( Excluding hard disk)
Clock Build-in system clock and calendar

I-1 IDE requirement: 1. There are 2 IDE ports in the main board: 1 is master and 1 is slave. 2. J4 IDE (the one close with power port) as master IDE port. 3. J10 IDE as slave IDE port. 4. Master hard disk must connect first before slave hard disk operate. 5. Also while 2 hard disks connect with IDE, they must be set with different jumpers to make this functional.
The DVR file information requires the conversion program (STMTOAVI.EXE which comes with the product) to make it as PC compatible and readable. It simply convert those *.stm file into *.avi file, which can play with media player from PC.
Here are some steps for STMTOAVI software instruction: 1. Click the STMTOAVI program to start. 2. Open file with select those *.stm file. 3. Start the conversion. 4. Provided with the output file name and output path. 5. After conversion, there will be a new file with *.avi and must used with DIVX playback software to run the avi file (DIVX version prefer with 5.03 or better).

Working Temperature 0~50 · Others · Working Humidity =80%