Suunto D6 Dive Computer

110 pages·5.9 MB·Watch·PDF·ENDEFRITNLJA
Suunto D6 Dive Computer
Table of Contents 106 sections Suunto D6 User's Manual · Table of Contents · 1. WELCOME TO THE WORLD OF SUUNTO DIVING INSTRUMENTS · 2. WARNINGS, CAUTIONS, AND NOTES · … ShowHide
Suunto D6 User's Manualp.1Table of Contentsp.31. WELCOME TO THE WORLD OF SUUNTO DIVING INSTRUMENTSp.72. WARNINGS, CAUTIONS, AND NOTESp.93. SUUNTO D6 AT A GLANCEp.153.1. Navigating in the menusp.163.2. Button symbols and functionsp.174. GETTING STARTED WITH YOUR SUUNTO D6p.194.1. TIME mode settingsp.194.1.1. Setting the alarmp.204.1.2. Setting the timep.214.1.3. Setting the dual timep.214.1.4. Setting the datep.224.1.5. Setting the unitsp.224.1.6. Setting the backlightp.234.1.7. Setting the tonesp.234.2. Stopwatchp.244.3. AC water contactsp.254.4. Learning how to use your compassp.264.4.1. Compass displayp.274.4.2. Locking a bearingp.284.4.3. Compass settingsp.29Declinationp.29Calibrationp.305. BEFORE DIVINGp.325.1. The Suunto RGBM/Deep Stop Algorithmp.335.2. Emergency ascentsp.335.3. Dive computer limitationsp.345.4. Nitroxp.345.5. Freedivingp.345.6. Audible and visual alarmsp.355.7. Error conditionsp.395.8. DIVE mode settingsp.405.8.1. Setting the depth alarmp.415.8.2. Setting the dive-time alarmp.425.8.3. Setting the nitrox valuesp.425.8.4. Setting the personal/altitude adjustmentsp.445.8.5. Setting the sample ratep.445.8.6. Setting the Safety Stops/Deep Stopsp.455.8.7. Setting the RGBM valuesp.455.9. Activation and pre-checksp.465.9.1. Accessing DIVE modep.465.9.2. DIVE mode activationp.465.9.3. Battery power indicationp.485.9.4. Diving at altitudep.495.9.5. Personal adjustmentsp.505.10. Safety Stopsp.525.10.1. Recommended Safety Stopsp.525.10.2. Mandatory Safety Stopsp.535.11. Deep stopsp.556. DIVINGp.566.1. Diving in AIR mode (DIVEair)p.566.1.1. Basic dive datap.566.1.2. Bookmarkp.586.1.3. Ascent rate indicatorp.596.1.4. Safety Stops and Deep Stopsp.606.1.5. Decompression divesp.60Ceiling, ceiling zone, floor and decompression rangep.61Display below the floorp.63Display above the floorp.63Display at the ceiling zonep.64Display above the ceilingp.656.2. Diving in NITROX mode (DIVEean)p.656.2.1. Before diving in NITROX modep.66Default nitrox settingsp.666.2.2. Oxygen displaysp.676.2.3. Oxygen limit fraction (OLF)p.696.2.4. Gas change and multiple breathing gas mixesp.706.3. Diving in GAUGE mode (DIVEgauge)p.717. AFTER DIVINGp.737.1. At the surfacep.737.1.1. Surface intervalp.737.1.2. Dive numberingp.747.1.3. Repetitive dive planningp.757.1.4. Flying after divingp.757.1.5. MEMORY modep.76Dive Planning mode (MEMplan)p.76Dive numbering shown during dive planningp.78Dive logbook (MEMlog)p.78Dive history (MEMhis)p.807.1.6. Suunto Dive Manager (SDM)p.817.1.7. SuuntoSports.comp.828. CARE AND MAINTENANCEp.848.1. Water contacts and buttonsp.848.2. Care of your dive computerp.848.3. Maintenancep.858.4. Water resistance inspectionp.868.5. Battery replacementp.879. TECHNICAL DATAp.889.1. Technical specificationsp.889.2. RGBMp.919.2.1. Suunto RGBM adaptive decompressionp.929.2.2. No-decompression limitsp.939.2.3. Altitude divingp.959.3. Oxygen exposurep.9610. INTELLECTUAL PROPERTYp.9710.1. Copyrightp.9710.2. Trademarkp.9710.3. Patent noticep.9711. DISCLAIMERSp.9811.1. User’s responsibilityp.9811.2. Limits of liability and ISO 9001 compliancep.9811.3. After sales servicep.9912. WARRANTYp.10013. DISPOSAL OF THE DEVICEp.102GLOSSARYp.103
Page 1 of the Suunto D6 Dive Computer user manual — Suunto D6 User's Manual
Page 1 · click to enlarge
Page 1
Page 1 of the Suunto D6 Dive Computer user manual — Suunto D6 User's Manual
Page 2 of the Suunto D6 Dive Computer user manual — Suunto D6 User's Manual
Page 2 · click to enlarge
Page 2

1 0 3 7 8 5 7 8 9 8 5 3 + x a F

4 2 1 9 - 3 4 5 ) 0 0 8 ( 1 e n o h P A S U o t n u u S

0 7 7 7 - 6 7 7 ) 0 0 8 ( 1 e n o h P a d a n a C

0 6 1 1 4 8 2 2 8 5 3 + e n o h P e p o r u E

0 7 8 5 7 8 9 8 5 3 + e n o h P y O o t n u u S

S T C A T N O C E C I V R E S R E M O T S U C

m o c . o t n u u s . w w w e ti s b e w o t n u u S

Page 3 of the Suunto D6 Dive Computer user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Suunto D6 User's Manualp.1Table of Contentsp.31. WELCOME TO THE WORLD OF SUUNTO DIVING INSTRUMENTSp.72. WARNINGS, CAUTIONS, AND NOTESp.93. SUUNTO D6 AT A GLANCEp.153.1. Navigating in the menusp.163.2. Button symbols and functionsp.174. GETTING STARTED WITH YOUR SUUNTO D6p.194.1. TIME mode settingsp.194.1.1. Setting the alarmp.204.1.2. Setting the timep.214.1.3. Setting the dual timep.214.1.4. Setting the datep.224.1.5. Setting the unitsp.224.1.6. Setting the backlightp.234.1.7. Setting the tonesp.234.2. Stopwatchp.244.3. AC water contactsp.254.4. Learning how to use your compassp.264.4.1. Compass displayp.274.4.2. Locking a bearingp.284.4.3. Compass settingsp.29Declinationp.29Calibrationp.305. BEFORE DIVINGp.325.1. The Suunto RGBM/Deep Stop Algorithmp.335.2. Emergency ascentsp.335.3. Dive computer limitationsp.345.4. Nitroxp.345.5. Freedivingp.345.6. Audible and visual alarmsp.355.7. Error conditionsp.395.8. DIVE mode settingsp.405.8.1. Setting the depth alarmp.415.8.2. Setting the dive-time alarmp.425.8.3. Setting the nitrox valuesp.425.8.4. Setting the personal/altitude adjustmentsp.445.8.5. Setting the sample ratep.445.8.6. Setting the Safety Stops/Deep Stopsp.455.8.7. Setting the RGBM valuesp.455.9. Activation and pre-checksp.465.9.1. Accessing DIVE modep.465.9.2. DIVE mode activationp.465.9.3. Battery power indicationp.485.9.4. Diving at altitudep.495.9.5. Personal adjustmentsp.505.10. Safety Stopsp.525.10.1. Recommended Safety Stopsp.525.10.2. Mandatory Safety Stopsp.535.11. Deep stopsp.556. DIVINGp.566.1. Diving in AIR mode (DIVEair)p.566.1.1. Basic dive datap.566.1.2. Bookmarkp.586.1.3. Ascent rate indicatorp.596.1.4. Safety Stops and Deep Stopsp.606.1.5. Decompression divesp.60Ceiling, ceiling zone, floor and decompression rangep.61Display below the floorp.63Display above the floorp.63Display at the ceiling zonep.64Display above the ceilingp.656.2. Diving in NITROX mode (DIVEean)p.656.2.1. Before diving in NITROX modep.66Default nitrox settingsp.666.2.2. Oxygen displaysp.676.2.3. Oxygen limit fraction (OLF)p.696.2.4. Gas change and multiple breathing gas mixesp.706.3. Diving in GAUGE mode (DIVEgauge)p.717. AFTER DIVINGp.737.1. At the surfacep.737.1.1. Surface intervalp.737.1.2. Dive numberingp.747.1.3. Repetitive dive planningp.757.1.4. Flying after divingp.757.1.5. MEMORY modep.76Dive Planning mode (MEMplan)p.76Dive numbering shown during dive planningp.78Dive logbook (MEMlog)p.78Dive history (MEMhis)p.807.1.6. Suunto Dive Manager (SDM)p.817.1.7. SuuntoSports.comp.828. CARE AND MAINTENANCEp.848.1. Water contacts and buttonsp.848.2. Care of your dive computerp.848.3. Maintenancep.858.4. Water resistance inspectionp.868.5. Battery replacementp.879. TECHNICAL DATAp.889.1. Technical specificationsp.889.2. RGBMp.919.2.1. Suunto RGBM adaptive decompressionp.929.2.2. No-decompression limitsp.939.2.3. Altitude divingp.959.3. Oxygen exposurep.9610. INTELLECTUAL PROPERTYp.9710.1. Copyrightp.9710.2. Trademarkp.9710.3. Patent noticep.9711. DISCLAIMERSp.9811.1. User’s responsibilityp.9811.2. Limits of liability and ISO 9001 compliancep.9811.3. After sales servicep.9912. WARRANTYp.10013. DISPOSAL OF THE DEVICEp.102GLOSSARYp.103
Page 7 of the Suunto D6 Dive Computer user manual — 1. WELCOME TO THE WORLD OF SUUNTO DIVING INSTRUMENTS
Page 7 · click to enlarge
Page 7

1. WELCOME TO THE WORLD OF SUUNTO DIVING INSTRUMENTS

Suunto D6 was designed to help you get the most out of your diving. After reading this manual and becoming familiar with the functions of your dive computer, you'll be ready to take the plunge into a whole new world of diving.

Suunto D6 Dive Computer — 1. WELCOME TO THE WORLD OF SUUNTO DIVING INSTRUMENTS diagram (page 7)
Fig. 1
Page 8 of the Suunto D6 Dive Computer user manual — 1. WELCOME TO THE WORLD OF SUUNTO DIVING INSTRUMENTS
Page 8 · click to enlarge
Page 8

With integrated digital compass and gas switching, Suunto D6 simplifies your diving experience because all the information you need relating to depth, time, decompression status, and direction is available on one easy-to-read screen – not hanging off you in a tangle of different gauges. To get the most out of your Suunto D6, please read this instruction manual carefully and make sure you understand the use, displays, and limitations of the instrument before using it. To make life easier, we've included a glossary of dive-specific terminology at the back of the manual.

Page 9 of the Suunto D6 Dive Computer user manual — 2. WARNINGS, CAUTIONS, AND NOTES
Page 9 · click to enlarge
Page 9

2. WARNINGS, CAUTIONS, AND NOTES

Throughout this manual, important safety icons are displayed. Three classifications are used to separate these icons by their order of importance:

Before you go on to read the manual itself, it is extremely important that you read the following warnings. These warnings are intended to maximize your safety while using Suunto D6 and must not be ignored.

WARNING READ THIS MANUAL! Carefully read this manual in its entirety, paying close attention to all the warnings listed below, including Section 5. BEFORE DIVING. Make sure that you fully understand the use, displays and limitations of the dive computer, because any confusion resulting from neglecting to follow this user's manual or from improper use of this device could cause you to commit errors that may lead to serious injury or death.

Page 10 of the Suunto D6 Dive Computer user manual — 2. WARNINGS, CAUTIONS, AND NOTES
Page 10 · click to enlarge
Page 10

WARNING THERE IS ALWAYS A RISK OF DECOMPRESSION ILLNESS (DCI) FOR ANY DIVE PROFILE, EVEN IF YOU FOLLOW THE DIVE PLAN PRESCRIBED BY DIVE TABLES OR A DIVE COMPUTER. NO PROCEDURE, DIVE COMPUTER, OR DIVE TABLE CAN PREVENT THE POSSIBILITY OF DCI OR OXYGEN TOXICITY! An individual’s physiological make-up can vary from day to day. The dive computer cannot account for these variations. You are strongly advised to remain well within the exposure limits provided by the instrument to minimize the risk of DCI. As an added precaution, you should consult a physician regarding your fitness before diving.

Page 11 of the Suunto D6 Dive Computer user manual — 2. WARNINGS, CAUTIONS, AND NOTES
Page 11 · click to enlarge
Page 11
Page 12 of the Suunto D6 Dive Computer user manual — 2. WARNINGS, CAUTIONS, AND NOTES
Page 12 · click to enlarge
Page 12

WARNING YOU ARE ADVISED TO AVOID FLYING ANY TIME THE COMPUTER COUNTS DOWN THE NO-FLY TIME. ALWAYS ACTIVATE THE COMPUTER TO CHECK THE REMAINING NO- FLY TIME PRIOR TO FLYING! Flying or traveling to a higher altitude within the no-fly time can greatly increase the risk of DCI. Review the recommendations given by Diver’s Alert Network (DAN) in Section 7.1.4. Flying after diving.

WARNING THE DIVE COMPUTER SHOULD NEVER BE TRADED OR SHARED BETWEEN USERS WHILE IT IS IN OPERATION! Its information will not apply to someone who has not been wearing it throughout a dive, or sequence of repetitive dives. Its dive profiles must match that of the user. If it is left on the surface during any dive, the dive computer will give inaccurate information for subsequent dives. No dive computer can take into account dives made without the computer. Thus, any diving activity up to four days prior to initial use of the computer may cause misleading information and must be avoided.

Page 13 of the Suunto D6 Dive Computer user manual — 2. WARNINGS, CAUTIONS, AND NOTES
Page 13 · click to enlarge
Page 13

WARNING THE DIVE COMPUTER WILL NOT ACCEPT FRACTIONAL PERCENTAGE VALUES OF OXYGEN CONCENTRATION. DO NOT ROUND UP FRACTIONAL PERCENTAGES! For example, 31.8% oxygen should be entered as 31%. Rounding up will cause nitrogen percentages to be understated and will affect decompression calculations. If you want to adjust the computer to provide more conservative calculations, use the personal adjustment feature to affect decompression calculations, or reduce the PO2 setting to affect oxygen exposure.

WARNING SELECT THE CORRECT ALTITUDE ADJUSTMENT SETTING! When diving at altitudes greater than 300 m/1,000 ft the Altitude Adjustment feature must be correctly selected in order for the computer to calculate the decompression status. The dive computer is not intended for use at altitudes greater than 3,000 m/10,000 ft. Failure to select the correct Altitude Adjustment setting, or diving above the maximum altitude limit will result in erroneous dive and planning data.

Page 14 of the Suunto D6 Dive Computer user manual — 2. WARNINGS, CAUTIONS, AND NOTES
Page 14 · click to enlarge
Page 14

NOTE It is not possible to change between AIR, NITROX and GAUGE modes before the instrument has counted down the no-fly time. There is one exception to this: You can change from AIR to NITROX mode even during the no-fly time. When planning both air and nitrox dives during the same dive series, you should set the instrument in NITROX mode and modify the gas mix accordingly. In GAUGE mode, the no-fly time is always 48 hours.

Page 15 of the Suunto D6 Dive Computer user manual — 3. SUUNTO D6 AT A GLANCE
Page 15 · click to enlarge
Page 15

3. SUUNTO D6 AT A GLANCE

Suunto D6 Dive Computer — 3. SUUNTO D6 AT A GLANCE diagram (page 15)
Fig. 2

Active Water Contact Indicator

Current Time Display Mode Indicator No-Decompression Time Total Ascent Time Ceiling Depth Safety/Deep Stop Time Surface Interval Time No-Fly Time Compass Display

Date Dual Time Maximum Depth PO2 (Nitrox Mode) Time

Ascent Rate Bar Graph

Seconds Display Stopwatch Weekday Dive Time Temperature PO2 (Nitrox Mode) OLF% (Nitrox Mode)

Show 7 more labels / short text on this page
Present Depth · Daily Alarm Indicator · Dive Alarm Indicator · Diver Attention Symbol · No-Fly Icon · Safety Stop Indicator · Low Battery Warning
Page 16 of the Suunto D6 Dive Computer user manual — 3.1. Navigating in the menus
Page 16 · click to enlarge
Page 16

3.1. Navigating in the menus Suunto D6 has three main operating modes - TIME mode (TIME), DIVE mode (DIVE), and MEMORY mode (MEM) – as well as the COMPASS submode, which can be activated from either TIME or DIVE modes. To toggle between the main modes, press the MODE button. To select a submode in DIVE and MEM mode, press the UP/DOWN buttons.

Suunto D6 Dive Computer — 3.1. Navigating in the menus diagram (page 16)
Fig. 3 · 3.1. Navigating in the menus
Page 17 of the Suunto D6 Dive Computer user manual — 3.2. Button symbols and functions
Page 17 · click to enlarge
Page 17

3.2. Button symbols and functions The table below explains the main functions of the dive computer's buttons. The buttons and their use will be explained in more detail in the relevant sections of the manual.

Table 3.1. Button symbols and functions

Suunto D6 Dive Computer — 3.2. Button symbols and functions diagram (page 17)
Fig. 4 · 3.2. Button symbols and functions

Switch between main modes Switch from submode to main mode Activate backlight in DIVE mode

Select a submode Select and accept settings Short SELECT

Activate compass in TIME and DIVE modes Long SELECT

Page 18 of the Suunto D6 Dive Computer user manual — 3.2. Button symbols and functions
Page 18 · click to enlarge
Page 18
Suunto D6 Dive Computer — 3.2. Button symbols and functions diagram (page 18)
Fig. 5 · 3.2. Button symbols and functions
Page 19 of the Suunto D6 Dive Computer user manual — 4. GETTING STARTED WITH YOUR SUUNTO D6
Page 19 · click to enlarge
Page 19

4. GETTING STARTED WITH YOUR SUUNTO D6

To get the most out of your Suunto D6, take some time to personalize it and really make it YOUR computer. Set the correct time and date, as well as the alarms and tones, unit and backlight settings, then calibrate and test the compass function. Suunto D6 is a very user-friendly dive computer, and you will quickly become familiar with its functions. Make absolutely sure that you know your computer and have it set up as you want it BEFORE getting into the water.

4.1. TIME mode settings The first thing you'll want to do with your Suunto D6, is to set the TIME mode shortcuts: alarm, time, dual time, date, units, backlight, and tones. In this section, we look at how to do this. Before that, however, take a look at the figure below, which shows how to toggle between different shortcuts in the TIME mode.

Suunto D6 Dive Computer — 4. GETTING STARTED WITH YOUR SUUNTO D6 diagram (page 19)
Fig. 6
Page 20 of the Suunto D6 Dive Computer user manual — 4.1.1. Setting the alarm
Page 20 · click to enlarge
Page 20

Now that you know how to toggle between the shortcuts, you can start to set them. The following figure shows how to enter the TIME SETTINGS menu.

Suunto D6 Dive Computer — 4.1.1. Setting the alarm diagram (page 20)
Fig. 7 · 4.1.1. Setting the alarm

USE UP AND DOWN BUTTONS TO TOGGLE BETWEEN ALARM, TIME, DUAL TIME, DATE, UNITS, BACKLIGHT

4.1.1. Setting the alarm The dive computer has a daily alarm function. When the daily alarm activates, the screen blinks and the alarm sounds for 24 seconds. Press any button to stop the alarm.

Page 21 of the Suunto D6 Dive Computer user manual — 4.1.2. Setting the time
Page 21 · click to enlarge
Page 21
Suunto D6 Dive Computer — 4.1.2. Setting the time diagram (page 21)
Fig. 8 · 4.1.2. Setting the time

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

4.1.2. Setting the time In the TIME SETTING mode, you are able to set the hour, minute, and second, as well as choose between 12 and 24 hour display.

Suunto D6 Dive Computer — 4.1.2. Setting the time diagram (page 21)
Fig. 9 · 4.1.2. Setting the time

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

4.1.3. Setting the dual time In the DUAL TIME SETTING mode you can select the hour and minute of a dual time - useful when traveling to a different time zone.

Page 22 of the Suunto D6 Dive Computer user manual — 4.1.4. Setting the date
Page 22 · click to enlarge
Page 22
Suunto D6 Dive Computer — 4.1.4. Setting the date diagram (page 22)
Fig. 10 · 4.1.4. Setting the date

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

4.1.4. Setting the date Use the DATE SETTING mode to set the year, month, and day. The day of the week is automatically calculated in accordance with the date.

Suunto D6 Dive Computer — 4.1.4. Setting the date diagram (page 22)
Fig. 11 · 4.1.4. Setting the date

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

4.1.5. Setting the units In the UNITS SETTING mode you can choose to have the units displayed in either the metric or imperial system - meters/feet, Celsius/Fahrenheit etc.

Page 23 of the Suunto D6 Dive Computer user manual — 4.1.6. Setting the backlight
Page 23 · click to enlarge
Page 23
Suunto D6 Dive Computer — 4.1.6. Setting the backlight diagram (page 23)
Fig. 12 · 4.1.6. Setting the backlight

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

4.1.6. Setting the backlight Use the BACKLIGHT SETTING mode to turn the backlight on or off and to define how long it stays on for (5, 10, 20, 30, or 60 seconds). When the backlight is turned off, it does not illuminate when an alarm sounds.

Suunto D6 Dive Computer — 4.1.6. Setting the backlight diagram (page 23)
Fig. 13 · 4.1.6. Setting the backlight

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

4.1.7. Setting the tones The TONE SETTING mode allows you to activate or deactivate the tones.

Page 24 of the Suunto D6 Dive Computer user manual — 4.2. Stopwatch
Page 24 · click to enlarge
Page 24
Suunto D6 Dive Computer — 4.2. Stopwatch diagram (page 24)
Fig. 14 · 4.2. Stopwatch

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

4.2. Stopwatch The Suunto D6’s stopwatch measures elapsed and split times. A separate stopwatch (dive timer) can also be used when in GAUGE mode. See Section 6.3. Diving in GAUGE mode (DIVEgauge).

Suunto D6 Dive Computer — 4.2. Stopwatch diagram (page 24)
Fig. 15 · 4.2. Stopwatch

USE DOWN BUTTON TO START STOPWATCH AND TAKE A SPLIT TIME. THE UP BUTTON STOPS THE STOPWATCH

Page 25 of the Suunto D6 Dive Computer user manual — 4.3. AC water contacts
Page 25 · click to enlarge
Page 25

4.3. AC water contacts The water and data transfer contact is located on the right side of the case. When submerged, the water contact is connected to the casing (which is the other pole of the water contact) by the conductivity of the water and the “AC” symbol appears on the display. The AC text is shown until the water contact deactivates.

Suunto D6 Dive Computer — 4.3. AC water contacts diagram (page 25)
Fig. 16 · 4.3. AC water contacts

AC APPEARS IN THE TOP RIGHT CORNER OF THE DISPLAY, WHEN THE DIVE COMPUTER IS IN CONTACT WITH WATER.

Contamination or dirt on the water contact may prevent this automatic activation. It is therefore important that the water contact is kept clean. The contact can be cleaned with fresh water and a soft brush, for example a tooth brush.

Page 26 of the Suunto D6 Dive Computer user manual — 4.4. Learning how to use your compass
Page 26 · click to enlarge
Page 26

NOTE Water or moisture build-up around the water contact may cause the contact to activate automatically. This can happen, for example, when washing your hands or sweating. If the water contact activates in the TIME mode, the AC symbol will appear on the display, and will be shown until the water contact deactivates. To save battery power, you should deactivate the water contact by cleaning it and/or drying it with a soft towel.

4.4. Learning how to use your compass Suunto D6 integrates a digital compass, which can be used both while diving and on dry land, and can be accessed from either the DIVE mode or TIME mode.

Page 27 of the Suunto D6 Dive Computer user manual — 4.4.1. Compass display
Page 27 · click to enlarge
Page 27
Suunto D6 Dive Computer — 4.4.1. Compass display diagram (page 27)
Fig. 17 · 4.4.1. Compass display

IF ACCESSED FROM TIME MODE, TIME AND BEARING ARE DISPLAYED AT THE BOTTOM OF THE SCREEN.

IF ACCESSED FROM DIVE MODE, CURRENT DEPTH AND TIME OR MAXIMUM DEPTH, AS WELL AS

4.4.1. Compass display The Suunto D6 displays the compass as a graphical representation of a compass rose. The rose displays the cardinal and half cardinal points, in addition to which, the current bearing is also displayed numerically.

Page 28 of the Suunto D6 Dive Computer user manual — 4.4.2. Locking a bearing
Page 28 · click to enlarge
Page 28

4.4.2. Locking a bearing A bearing can be locked to help you follow a selected course, and directional arrows point towards the locked bearing. Locked bearings are stored in the memory for later analysis and are available the next time the compass is activated.

Suunto D6 Dive Computer — 4.4.2. Locking a bearing diagram (page 28)
Fig. 18 · 4.4.2. Locking a bearing

The Suunto D6 also provides help for navigating square and triangular patterns, as well as navigating a return heading. This is made possible by following graphical symbols in the center of the compass display:

Table 4.1. Locked bearing symbols

Suunto D6 Dive Computer — 4.4.2. Locking a bearing diagram (page 28)
Fig. 19 · 4.4.2. Locking a bearing

You are 90 (or 270) degrees from the locked bearing

Page 29 of the Suunto D6 Dive Computer user manual — 4.4.3. Compass settings
Page 29 · click to enlarge
Page 29

You are 120 (or 240) degrees from the locked bearing

4.4.3. Compass settings You can define the compass settings (declination and calibration) when in COMPASS mode:

Suunto D6 Dive Computer — 4.4.3. Compass settings diagram (page 29)
Fig. 20 · 4.4.3. Compass settings

Declination You can compensate for the difference between true north and magnetic north by adjusting the compass declination. The declination can be found, for example, from sea charts or topographic maps of the local area.

Explanation Symbol

Page 30 of the Suunto D6 Dive Computer user manual — Calibration
Page 30 · click to enlarge
Page 30
Suunto D6 Dive Computer — Calibration diagram (page 30)
Fig. 21 · Calibration

Calibration Because of changes in the surrounding magnetic field, the Suunto D6 electronic compass occasionally needs to be re-calibrated. During the calibration process, the compass adjusts itself to the surrounding magnetic field. As a basic rule, you should calibrate the compass whenever it doesn’t seem to operate properly, or after replacing the dive computer's battery. Strong electromagnetic fields, such as powerlines, stereo speakers, and magnets can affect the compass calibration. It is therefore advisable to calibrate the compass if your Suunto D6 has been exposed to these fields.

To calibrate the compass:

Page 31 of the Suunto D6 Dive Computer user manual — Calibration
Page 31 · click to enlarge
Page 31
Suunto D6 Dive Computer — Calibration diagram (page 31)
Fig. 22 · Calibration

If the calibration fails several times in a row, it is possible that you are in an area with sources of magnetism, such as large metal objects, powerlines or electric appliances. Move to another location and try to calibrate the compass again. If the calibration continues to fail, contact an authorized Suunto service center.

Page 32 of the Suunto D6 Dive Computer user manual — 5. BEFORE DIVING
Page 32 · click to enlarge
Page 32

5. BEFORE DIVING

Do not attempt to use the dive computer without reading this user's manual in its entirety, including all the warnings. Make sure that you fully understand the use, displays, and limitations of the instrument. If you have any questions about the manual or the Suunto D6, please contact your Suunto representative before diving with the dive computer. Always remember that YOU ARE RESPONSIBLE FOR YOUR OWN SAFETY! When used properly, Suunto D6 is an outstanding tool for assisting properly trained, certified divers in planning and executing sport dives. It is NOT A SUBSTITUTE FOR CERTIFIED SCUBA INSTRUCTION, including training in the principles of decompression.

Do not attempt to dive with any gas mix other than standard air without first receiving certified training in this specialty.

Page 33 of the Suunto D6 Dive Computer user manual — 5.1. The Suunto RGBM/Deep Stop Algorithm
Page 33 · click to enlarge
Page 33

5.1. The Suunto RGBM/Deep Stop Algorithm Suunto’s Reduced Gradient Bubble Model (RGBM), utilized in the Suunto D6, predicts both dissolved and free gas in the blood and tissues of divers. It is a significant advance on the classic Haldane models, which do not predict free gas. The advantage of Suunto RGBM is additional safety through its ability to adapt to a variety of situations and dive profiles. The Suunto D6 allows you to choose between a traditional Recommended Safety Stop and Deep Stops. Deep Stops are safety stops that occur deeper than traditional stops, with the purpose of minimizing microbubble formation. In order to optimize the response to different increased risk situations, an additional category of stop, referred to as a Mandatory Safety Stop, has been introduced. The combination of stop types depends on the user settings and the specific dive situation. To get the most from the RGBM safety benefits, refer to Section 9.2. RGBM.

5.2. Emergency ascents In the unlikely event that the dive computer malfunctions during a dive, follow the emergency procedures provided by your certified dive training agency or, alternatively, follow these steps: 1. Assess the situation calmly and then move promptly to less than 18 m/60 ft. 2. At 18 m/60 ft, slow down your ascent rate to 10 m/33 ft per minute and move to a depth between 3 and 6 m/10 and 20 ft. 3. Stay there for as long as your air supply will safely allow. After reaching the surface, do not dive for at least 24 hours.

Page 34 of the Suunto D6 Dive Computer user manual — 5.3. Dive computer limitations
Page 34 · click to enlarge
Page 34

5.3. Dive computer limitations While the dive computer's calculations are based on current decompression research and technology, it is important to realize that the computer cannot monitor the actual physiological functions of an individual diver. All decompression schedules currently known to the authors, including the U.S. Navy Tables, are based on theoretical mathematical models, which are intended to serve as a guide to reduce the probability of decompression illness.

5.4. Nitrox Diving with nitrox provides you with an opportunity to increase bottom times or reduce the risk of decompression illness by reducing the nitrogen content in the gas mix. However, when the gas mix is altered, the oxygen content of the mix is generally increased. This increase exposes the diver to an oxygen toxicity risk not usually considered in recreational diving. In order to manage this risk, the dive computer tracks the time and intensity of the oxygen exposure and provides the diver with information to adjust the dive plan in order to maintain oxygen exposure within reasonably safe limits. In addition to the physiological effects of enriched air on the body, there are operational considerations to be addressed when handling altered breathing mixes. Elevated concentrations of oxygen present a fire or explosion hazard. Consult the manufacturer of your equipment to check its compatibility with nitrox.

5.5. Freediving Freediving, and particularly freediving in combination with scuba diving, may present risks that have not been researched and are not commonly known.

Page 35 of the Suunto D6 Dive Computer user manual — 5.6. Audible and visual alarms
Page 35 · click to enlarge
Page 35

Anyone who engages in any form of breathhold diving is in danger of shallow-water blackout (SWB), that is, the sudden loss of consciousness caused by oxygen starvation. Any breathhold diving results in some nitrogen build-up in the blood and other fast tissues. Due to the short time spent at depth, this build-up is generally not significant. Therefore, provided the effort involved in freediving has not been severe, there is little risk in diving after breathhold diving. However, the reverse is more unknown and may significantly increase the risk of DCI. Therefore, FREEDIVING AFTER SCUBA DIVING IS NOT RECOMMENDED. You should avoid freediving, and not exceed 5 m/16 ft, for at least two hours after scuba diving.

5.6. Audible and visual alarms The dive computer features audible and visual alarms that advise when important limits are approached or that prompt you to acknowledge preset alarms. The table below describes the different alarms and their meanings.

Page 36 of the Suunto D6 Dive Computer user manual — 5.6. Audible and visual alarms
Page 36 · click to enlarge
Page 36

Table 5.1. Audible and visual alarm types

Alarm reason Alarm type

Dive computer is activated. Short single beep

Dive computer automatically returns to the TIME mode.

Three beeps with a three second interval and activated backlight

No-decompression dive turns into a Decompression Stop dive. An arrow pointing upwards and the blinking ascent warning ASC TIME will appear.

Continuous beeps and activated backlight

Maximum allowed ascent rate, 10 m per min/33 ft per min, is exceeded. Ascent rate bar graph blinks and STOP warning appears.

Decompression ceiling depth is exceeded. An Error warning (Er) and a downward pointing arrow appear. You should immediately descend to, or below, the ceiling. The instrument will otherwise enter a permenant Error mode within three minutes, indicated by a permanent Er symbol.

You are able to preset alarms before the dive. The programmable alarms can be set for maximum depth, dive time and time. See also Section 5.8. DIVE mode settings and Section 4.1. TIME mode settings.

Page 37 of the Suunto D6 Dive Computer user manual — 5.6. Audible and visual alarms
Page 37 · click to enlarge
Page 37

Table 5.2. Preset alarm types

Alarm reason Alarm type

Preset maximum depth is reached. Continuous beep series for 24 seconds Maximum depth blinks as long as the current depth value exceeds the preset value.

Preset dive time is reached. Continuous beep series for 24 seconds or until any button is pressed. Dive time blinks for one minute.

Preset alarm time is reached. Current time is shown Continuous beep series for 24 seconds or until any button is pressed. Current time blinks for one minute

Page 38 of the Suunto D6 Dive Computer user manual — 5.6. Audible and visual alarms
Page 38 · click to enlarge
Page 38

Table 5.3. Oxygen alarms in NITROX mode

Alarm reason Alarm type

Continuous beeps for 3 minutes and activated backlight

Set oxygen partial pressure limit is exceeded. The alternative display is replaced with a current blinking PO2 value. You should immediately ascend above the PO2 depth limit.

OLF value reaches 80%. The OLF value will start to blink.

OLF value reaches 100%. The OLF value will blink.

Page 39 of the Suunto D6 Dive Computer user manual — 5.7. Error conditions
Page 39 · click to enlarge
Page 39

5.7. Error conditions The dive computer has warning indicators that alert you to react to certain situations that would significantly increase the risk of DCI. If you do not respond to its warnings, the dive computer will enter an Error mode, indicating that the risk of DCI has greatly increased. If you understand the dive computer and operate it sensibly, it is very unlikely you will ever put the instrument into the Error mode. Omitted decompression The Error mode results from omitted decompression, i.e. when you stay above the ceiling for more than three minutes. During this three-minute period the Er warning is shown and the audible alarm beeps. After this, the dive computer will enter a permanent Error mode. The instrument will continue to function normally if you descend below the ceiling within this three-minute period. Once in the permanent Error mode, only the Er warning is shown in the center window. The dive computer will not show times for ascent or stops. However, all the other displays will function as before to provide information for ascent. You should immediately ascend to a depth of 3 to 6 m/10 to 20 ft and remain at this depth until air supply limitations require you to surface. After surfacing, you should not dive for a minimum of 48 hours. During the permanent Error mode, the Er text will be displayed in the center window and the planning mode will be disabled.

Page 40 of the Suunto D6 Dive Computer user manual — X X RGBM
Page 40 · click to enlarge
Page 40

5.8. DIVE mode settings Suunto D6 has several user-definable functions, as well as depth and time-related alarms that you can set according to your personal preferences. The DIVE mode settings are dependent on the dive sub-mode chosen (AIR, EAN, GAUGE), so that, for example, nitrox settings are only available in the DIVEean sub-mode. The table below shows what dive settings are available in each DIVE submode.

Table 5.4. DIVE mode settings

GAUGE mode NITROX mode AIR mode Setting

X X X Depth alarm

X X X Dive-time alarm

X X X Sample rate

X X Safety/Deep stop

X X RGBM

X X X Units

The following figure shows how to enter the DIVE mode settings menu.

X Nitrox · X X Personal/Altitude

Page 41 of the Suunto D6 Dive Computer user manual — 5.8.1. Setting the depth alarm
Page 41 · click to enlarge
Page 41
Suunto D6 Dive Computer — 5.8.1. Setting the depth alarm diagram (page 41)
Fig. 23 · 5.8.1. Setting the depth alarm

5.8.1. Setting the depth alarm You can set a depth alarm in the dive computer.

Suunto D6 Dive Computer — 5.8.1. Setting the depth alarm diagram (page 41)
Fig. 24 · 5.8.1. Setting the depth alarm

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

Page 42 of the Suunto D6 Dive Computer user manual — 5.8.2. Setting the dive-time alarm
Page 42 · click to enlarge
Page 42

The depth alarm is factory-set to 40 m/131 ft, but you can adjust it according to your personal preference, or switch it off altogether. The depth range can be set from 3m to 100 m/9 ft to 328 ft.

5.8.2. Setting the dive-time alarm The Suunto D6 has a dive-time alarm setting which, when activated, can be used for several purposes to add to your diving safety.

Suunto D6 Dive Computer — 5.8.2. Setting the dive-time alarm diagram (page 42)
Fig. 25 · 5.8.2. Setting the dive-time alarm

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

5.8.3. Setting the nitrox values If set to the NITROX mode, the correct oxygen percentage of the gas in your cylinder (and additional gases) must always be entered into the computer to ensure correct nitrogen and oxygen calculations. In addition, the oxygen partial pressure limit must be set. When in the Nitrox setting mode, the equivalent allowed maximum depth, based on the chosen setting, will also be displayed. Settings for an additional mix (MIX2) are made similarly, but with the additional selection of “ON” or “OFF”.

Page 43 of the Suunto D6 Dive Computer user manual — 5.8.2. Setting the dive-time alarm
Page 43 · click to enlarge
Page 43

In order to minimize the risk of error during a dive, it is highly recommended that the mixes are set in the proper order. This means that as the mix number rises, so does oxygen content, and this is the order they are usually used during the dive. Before a dive, only set to “ON” the mixes you actually have available and remember to check the set values to make sure they are correct. The default oxygen percentage (O2%) setting is 21% (air) and oxygen partial pressure (PO2) setting 1.4 bar. After entering values for MIX1, you can enable/disable and set an additional gas mix - MIX2.

Suunto D6 Dive Computer — 5.8.2. Setting the dive-time alarm diagram (page 43)
Fig. 26 · 5.8.2. Setting the dive-time alarm

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT

Page 44 of the Suunto D6 Dive Computer user manual — 5.8.4. Setting the personal/altitude adjustments
Page 44 · click to enlarge
Page 44

5.8.4. Setting the personal/altitude adjustments The current Altitude and Personal Adjustment settings are displayed in the startup screen when entering the DIVE mode. If the mode does not match the altitude or personal conditions (see Section 5.9.4. Diving at altitude and Section 5.9.5. Personal adjustments), it is imperative that you enter the correct selection before diving. Use Altitude Adjustment to select the correct altitude and use Personal Adjustment to add an extra level of conservatism.

Suunto D6 Dive Computer — 5.8.4. Setting the personal/altitude adjustments diagram (page 44)
Fig. 27 · 5.8.4. Setting the personal/altitude adjustments

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

5.8.5. Setting the sample rate The sample rate controls how often the depth, time, and water temperature is stored in the memory. You can set the dive profile sample rate to 1, 10, 20, 30, or 60 seconds. The factory default setting is 20 seconds.

Suunto D6 Dive Computer — 5.8.4. Setting the personal/altitude adjustments diagram (page 44)
Fig. 28 · 5.8.4. Setting the personal/altitude adjustments

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

Page 45 of the Suunto D6 Dive Computer user manual — 5.8.6. Setting the Safety Stops/Deep Stops
Page 45 · click to enlarge
Page 45

5.8.6. Setting the Safety Stops/Deep Stops The Deep Stop setting allows you to choose between traditional Safety Stops or Deep Stops. If Deep Stops are set to OFF, the traditional Safety Stop calculation is used. If set to ON, iterative Deep Stops will be prompted instead. The length of the individual Deep Stops can be set to 1 or 2 minutes.

Suunto D6 Dive Computer — 5.8.6. Setting the Safety Stops/Deep Stops diagram (page 45)
Fig. 29 · 5.8.6. Setting the Safety Stops/Deep Stops

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

5.8.7. Setting the RGBM values For certain divers and diving conditions, it may be desirable to set the attenuated RGBM mode. The selection is displayed during the DIVE mode startup. The options are full RGBM effects (100%), and attenuated RGBM (50%).

Suunto D6 Dive Computer — 5.8.6. Setting the Safety Stops/Deep Stops diagram (page 45)
Fig. 30 · 5.8.6. Setting the Safety Stops/Deep Stops

ADJUST WITH UP AND DOWN BUTTONS. ACCEPT WITH SELECT BUTTON.

Page 46 of the Suunto D6 Dive Computer user manual — 5.9. Activation and pre-checks
Page 46 · click to enlarge
Page 46

5.9. Activation and pre-checks This section describes how to activate the DIVE mode and explains the pre-checks that it is highly recommended you perform before you get into the water.

5.9.1. Accessing DIVE mode The Suunto D6 has three diving modes: AIR mode for diving with standard air only, NITROX mode for diving with oxygen enriched mixtures, and GAUGE mode for use as a bottom timer and for freediving. The OFF mode disables the DIVE mode, and allows the TIME mode to be used underwater. The chosen dive mode is displayed when the DIVE mode is accessed, and you can toggle between the submodes by pressing the UP/DOWN buttons.

Suunto D6 Dive Computer — 5.9. Activation and pre-checks diagram (page 46)
Fig. 31 · 5.9. Activation and pre-checks

5.9.2. DIVE mode activation The dive computer activates automatically when submerged deeper than 0.5 m/1.5 ft. However, it is necessary to activate the DIVE mode BEFORE diving to check the altitude and personal adjustment settings, battery condition, oxygen settings etc.

Page 47 of the Suunto D6 Dive Computer user manual — 5.9. Activation and pre-checks
Page 47 · click to enlarge
Page 47

After activation, all display elements turn on showing mostly figure 8s and graphical elements, and the backlight and the beep are activated. After this, the selected altitude and personal settings are displayed, as well as the RGBM and Deep Stop status. A few seconds later the battery power indicator is shown.

Suunto D6 Dive Computer — 5.9. Activation and pre-checks diagram (page 47)
Fig. 32 · 5.9. Activation and pre-checks
  • At this time, perform your pre-checks, making sure that:
  • the instrument operates in the correct mode and provides a complete display (AIR/NITROX/GAUGE mode)
  • the battery level is ok
  • the altitude, personal adjustment, Safety/Deep stops, and RGBM settings are correct
  • the instrument displays correct units of measurement (Metric/Imperial)
  • the instrument displays the correct temperature and depth (0.0 m/0 ft)
  • the alarm beeps And, if set to NITROX mode, make sure that:
  • the correct number of mixes is set and that the oxygen percentages are adjusted according to the measured nitrox blends in your cylinders
  • the oxygen partial pressure limits are set correctly
Page 48 of the Suunto D6 Dive Computer user manual — 5.9.3. Battery power indication
Page 48 · click to enlarge
Page 48

For more information on the NITROX mode, refer to Section 6.2. Diving in NITROX mode (DIVEean). The dive computer is now ready for diving.

5.9.3. Battery power indication Temperature or internal oxidation of the battery affect the battery voltage. If the instrument is stored for a long period, or used in cold temperatures, the low battery warning may be displayed even though the battery has enough capacity. In these cases, re-enter DIVE mode to receive the battery power indication. After the battery check, the Low Battery Warning is indicated by the battery symbol.

Suunto D6 Dive Computer — 5.9.3. Battery power indication diagram (page 48)
Fig. 33 · 5.9.3. Battery power indication

If the battery symbol is displayed in the Surface mode, or if the display is faded or weak, the battery may be too low to operate the dive computer, and battery replacement is recommended.

Page 49 of the Suunto D6 Dive Computer user manual — 5.9.4. Diving at altitude
Page 49 · click to enlarge
Page 49

5.9.4. Diving at altitude The dive computer can be adjusted both for diving at altitude and also to increase the conservatism of the mathematical nitrogen model. When programming the instrument for the correct altitude, you need to select the correct Altitude Adjustment settings according to Table 5.5, Altitude Adjustment settings. The dive computer will adjust its mathematical model according to the entered altitude setting, giving shorter no-decompression times at higher altitudes (see Table 9.1, No- decompression time limits for various depths (m) and Table 9.2, No-decompression time limits for various depths (ft) in Section 9.2. RGBM).

Table 5.5. Altitude Adjustment settings

Altitude range Alt. adjustment value

0. 300 m / 0 - 1000 ft A0
300. 1500 m / 1000 - 5000 ft A1

1500 - 3000 m / 5000 - 10 000 ft A2

Page 50 of the Suunto D6 Dive Computer user manual — 5.9.5. Personal adjustments
Page 50 · click to enlarge
Page 50
  • 5.9.5. Personal adjustments There are personal factors that can affect your susceptibility to DCI, which you can predict in advance, and input into the decompression model. Such factors vary between divers and also for the same diver from one day to another. The three-step Personal Adjustment setting is available if a more conservative dive plan is desired and, for very experienced divers, a two step adjustment for RGBM effect on repetitive dives is available. The personal factors which tend to increase the possibility of DCI include, but are not limited to:
  • cold exposure - water temperature less than 20 °C/68 °F
  • below average physical fitness level
  • fatigue
  • dehydration
  • previous history of DCI
  • stress
  • obesity This feature is used to adjust the computer to be more conservative, according to personal preference, by entering the suitable Personal Adjustment setting with the help of Table 5.6, Personal Adjustment settings . In ideal conditions, retain the default setting, P0. If conditions are more difficult, or any of the factors which tend to increase the possibility of DCI exist, select P1, or even the most conservative P2. The dive computer then adjusts its mathematical model according to the entered Personal Adjustment setting, giving shorter no-decompression times (see Section 9.2.2. Nodecompression limits , Table 9.1, No-decompression time limits for various depths (m) and Table 9.2, No-decompression time limits for various depths (ft) ). 50
Page 51 of the Suunto D6 Dive Computer user manual — 5.9.5. Personal adjustments
Page 51 · click to enlarge
Page 51

Table 5.6. Personal Adjustment settings

Desired tables Condition Personal adjustment value

Default Ideal conditions P0

Progressively more conservative Some risk factors or conditions exist P1

Several risk factors or conditions exist P2

The Suunto D6 also allows experienced divers who are willing to accept a greater level of risk to adjust the RGBM model. The default setting is 100%, which gives full RGBM effect. Suunto strongly advises you to use full RGBM effect. Statistically, very experienced divers have less incidents with DCI. The reason for this is unknown, but it is possible that some level of physiological and/or psychological accommodation can take place when you are very experienced as a diver. Thus, for certain divers and diving conditions, it may be desirable to set attenuated (50%) RGBM mode. See Table 5.7, RGBM model settings.

Table 5.7. RGBM model settings

Effect Desired Tables RGBM setting

Full RGBM effects Standard Suunto RGBM model (Default) 100%

Page 52 of the Suunto D6 Dive Computer user manual — 5.10. Safety Stops
Page 52 · click to enlarge
Page 52

Effect Desired Tables RGBM setting

Smaller RGBM effects, higher risk! Attenuated RGBM model 50%

5.10. Safety Stops Safety Stops are widely considered good diving practice for recreational diving, and are an integral part of most dive tables. The reasons for performing a Safety Stop include: reducing sub-clinical DCI, microbubble reduction, ascent control, and orientation before surfacing. The Suunto D6 displays two different types of Safety Stops: Recommended Safety Stop and Mandatory Safety Stop.

5.10.1. Recommended Safety Stops With every dive over 10 meters, there is a three minute countdown for the Recommended Safety Stop, to be taken in the 6 - 3 m/10 ft - 20 ft range. This is shown with the STOP sign and a three-minute countdown in the center window instead of the no-decompression time.

Page 53 of the Suunto D6 Dive Computer user manual — 5.10.2. Mandatory Safety Stops
Page 53 · click to enlarge
Page 53
Suunto D6 Dive Computer — 5.10.2. Mandatory Safety Stops diagram (page 53)
Fig. 34 · 5.10.2. Mandatory Safety Stops

5.10.2. Mandatory Safety Stops When the ascent rate exceeds 12 m/40 ft per minute momentarily, or 10 meters/33ft per minute continuously, the microbubble build-up is predicted to be more than is allowed for in the decompression model. When the ascent rate exceeds 10 m/33 ft per minute continuously for more than 5 seconds, the microbubble build-up is predicted to be more than is allowed for in the decompression model. The Suunto RGBM calculation model responds to this by adding a Mandatory Safety Stop to the dive. The time of this Mandatory Safety Stop depends on the severity of the ascent rate excess.

Page 54 of the Suunto D6 Dive Computer user manual — 5.10.2. Mandatory Safety Stops
Page 54 · click to enlarge
Page 54

The STOP sign appears in the display and when you reach the depth zone between 6 m and 3 m/20 ft and 10 ft, the CEILING label, ceiling depth, and the calculated Safety Stop time also appear in the display. You should wait until the Mandatory Safety Stop warning disappears. The total length of the Mandatory Safety Stop time depends on the seriousness of the ascent rate violation.

Suunto D6 Dive Computer — 5.10.2. Mandatory Safety Stops diagram (page 54)
Fig. 35 · 5.10.2. Mandatory Safety Stops

WHEN CEILING AND STOP ARE DISPLAYED, MAKE A ONE MINUTE MANDATORY SAFETY STOP IN THE

You must not ascend shallower than 3 m/10 ft with the Mandatory Safety Stop warning on. If you ascend above the Mandatory Safety Stop ceiling, a downward pointing arrow will appear and a continuous beeping starts. You should immediately descend to, or below, the Mandatory Safety Stop ceiling depth. If you correct this situation at any time during the dive, there are no effects on the decompression calculations for future dives.

Page 55 of the Suunto D6 Dive Computer user manual — 5.11. Deep stops
Page 55 · click to enlarge
Page 55
Suunto D6 Dive Computer — 5.11. Deep stops diagram (page 55)
Fig. 36 · 5.11. Deep stops

WHEN CEILING AND STOP ARE DISPLAYED, IMMEDIATELY (WITHIN 3 MINUTES) DESCEND

If you continue to violate the Mandatory Safety Stop, the tissue calculation model is affected and the dive computer shortens the available no-decompression time for your next dive. In this situation, it is recommended that you prolong your surface interval time before your next dive.

5.11. Deep stops The Suunto D6 allows you to choose a Deep Stop algorithm instead of the traditional Recommended Safety Stop. Deep Stops are safety stops that occur deeper than traditional stops, with the purpose of minimizing microbubble formation and excitation. The Suunto RGBM model calculates deep stops iteratively, placing the first stop about halfway between the maximum depth and the ceiling depth. After the first Deep Stop is completed, another Deep Stop will be prompted halfway to the ceiling, and so on until the ceiling depth is reached. The Deep Stop length can be set to 1 or 2 minutes. Enabling the Deep Stops disables the Recommended Safety Stops, but Mandatory Safety Stops due to continuous ascent rate violations, for example, are still prompted.

Page 56 of the Suunto D6 Dive Computer user manual — 6. DIVING
Page 56 · click to enlarge
Page 56

6. DIVING

This section contains instructions on how to operate the dive computer and interpret its displays. You’ll find that this dive computer is easy to use and read. Each display shows only the data relevant to that specific diving mode.

6.1. Diving in AIR mode (DIVEair) In this section, we look at how to make the most of the dive computer when diving with standard air. To activate DIVEair mode, please see Section 5.9.1. Accessing DIVE mode.

Suunto D6 Dive Computer — 6. DIVING diagram (page 56)
Fig. 37

DIVE HAS JUST BEGUN AND AVAILABLE NO-DECOMPRESSION TIME IS OVER 99 MINUTES SO NO

6.1.1. Basic dive data During a No-decompression dive, the following information is displayed:

Page 57 of the Suunto D6 Dive Computer user manual — 6. DIVING
Page 57 · click to enlarge
Page 57
  • your present depth in meters/feet
  • the available no-decompression time in minutes as NO DEC TIME
  • the ascent rate presented as a bar graph on the right side
  • the Diver Attention Symbol if surface interval should be prolonged (see Table 7.1, Alarms )
Suunto D6 Dive Computer — 6. DIVING diagram (page 57)
Fig. 38

DIVE DISPLAY - PRESENT DEPTH IS 15 M, NO-DECOMPRESSION STOP TIME LIMIT IS 61 MIN. MAXIMUM DEPTH DURING THIS DIVE WAS 21.5 M,

  • Alternative displays, by pressing the UP/DOWN buttons, show:
  • the elapsed dive time in minutes, shown as DIVE TIME
  • the water temperature in °C/°F
  • the maximum depth during this dive in meters/feet, indicated as MAX
  • the current time, shown as TIME
Suunto D6 Dive Computer — 6. DIVING diagram (page 57)
Fig. 39

DOWN BUTTON TOGGLES BETWEEN MAXIMUM DEPTH AND CURRENT TIME.

Page 58 of the Suunto D6 Dive Computer user manual — 6.1.2. Bookmark
Page 58 · click to enlarge
Page 58
Suunto D6 Dive Computer — 6.1.2. Bookmark diagram (page 58)
Fig. 40 · 6.1.2. Bookmark

UP BUTTON TOGGLES BETWEEN DIVE TIME AND WATER TEMPERATURE.

6.1.2. Bookmark It is possible to record bookmarks in the profile memory during a dive. These bookmarks are displayed when scrolling the profile memory on the display. The bookmarks will also be shown as annotations in the downloadable Suunto Dive Manager PC software. The bookmark logs the depth, time, and water temperature, as well as compass heading (if the compass has been enabled). To make a bookmark in the profile memory during a dive, press the SELECT button. A brief confirmation will be given.

Suunto D6 Dive Computer — 6.1.2. Bookmark diagram (page 58)
Fig. 41 · 6.1.2. Bookmark

A BOOKMARK IS PLACED IN THE PROFILE MEMORY DURING A DIVE BY PRESSING

Page 59 of the Suunto D6 Dive Computer user manual — 6.1.3. Ascent rate indicator
Page 59 · click to enlarge
Page 59

6.1.3. Ascent rate indicator The ascent rate is shown graphically along the right side of the display. When the maximum allowed ascent rate is exceeded, the fifth SLOW warning segment and the STOP sign appear and the depth reading starts to blink, indicating that the maximum ascent rate has been exceeded continuously or that the current ascent rate is significantly above the allowed rate.

Suunto D6 Dive Computer — 6.1.3. Ascent rate indicator diagram (page 59)
Fig. 42 · 6.1.3. Ascent rate indicator

ACTIVATED BACKLIGHT, ALARM AND A BLINKING ASCENT RATE BAR GRAPH INDICATE YOU ARE ASCENDING FASTER THAN 10 M/MIN. YOU ARE ADVISED

WARNING DO NOT EXCEED THE MAXIMUM ASCENT RATE! Rapid ascents increase the risk of injury. You should always make the Mandatory and Recommended Safety Stops after you have exceeded the maximum recommended ascent rate. If this Mandatory Safety Stop is not completed, the decompression model will penalize your next dive(s). Continuous ascent rate violations will result in Mandatory Safety Stops. When Recommended Deep Stop is enabled, the length is indicated in seconds.

Page 60 of the Suunto D6 Dive Computer user manual — 6.1.4. Safety Stops and Deep Stops
Page 60 · click to enlarge
Page 60

6.1.4. Safety Stops and Deep Stops If Deep Stops are not used, a 3 minute Recommended Safety Stop is prompted after every dive to over 10m.

Suunto D6 Dive Computer — 6.1.4. Safety Stops and Deep Stops diagram (page 60)
Fig. 43 · 6.1.4. Safety Stops and Deep Stops

YOU ARE ADVISED TO MAKE A DEEPSTOP AT 12 M. THE SECOND INDICATOR SHOWS THAT YOU HAVE 58 SECONDS LEFT OF YOUR DEEPSTOP.

6.1.5. Decompression dives When your NO DEC TIME becomes zero, your dive becomes a decompression dive so you must perform one or more decompression stops on your way to the surface. The NO DEC TIME on your display will be replaced by an ASC TIME, and a CEILING notation will appear. An upward pointing arrow will also prompt you to start your ascent. If you exceed the no-decompression limits on a dive, the dive computer will provide the decompression information required for ascent. After this, the instrument will continue to provide subsequent interval and repetitive dive information. Rather than requiring you to make stops at fixed depths, the dive computer lets you decompress within a range of depths (continuous decompression). The ascent time (ASC TIME) is the minimum amount of time needed to reach the surface in a decompression dive. It includes: • the time needed to ascend to the ceiling at an ascent rate of 10 m per minute/33 ft per minute. The ceiling is the shallowest depth to which you should ascend

Page 61 of the Suunto D6 Dive Computer user manual — Ceiling, ceiling zone, floor and decompression range
Page 61 · click to enlarge
Page 61
  • the time needed at the ceiling
  • the time needed at the Mandatory Safety Stop (if any)
  • the time needed to reach the surface after the ceiling and Safety Stops have been completed
  • WARNING YOUR ACTUAL ASCENT TIME MAY BE LONGER THAN DISPLAYED BY THE INSTRUMENT! The ascent time will increase if you:
  • remain at depth
  • ascend slower than 10 m/33 ft per minute
  • make your decompression stop deeper than at the ceiling These factors will also increase the amount of air required to reach the surface.
  • Ceiling, ceiling zone, floor and decompression range When in decompression, it is important that you understand the meaning of ceiling, floor, and decompression range.
  • The ceiling is the shallowest depth to which you should ascend when in decompression. At this depth, or below, you must perform all stops
  • The ceiling zone is the optimum decompression stop zone. It is the zone between the minimum ceiling and 1.8 m/6 ft below the minimum ceiling
  • The floor is the deepest depth at which the decompression stop time will not increase. Decompression will start when you pass this depth during your ascent
Page 62 of the Suunto D6 Dive Computer user manual — Ceiling, ceiling zone, floor and decompression range
Page 62 · click to enlarge
Page 62
  • The decompression range is the depth range between the ceiling and floor. Within this range, decompression takes place. However, it is important to remember that the decompression will be very slow at, or close to, the floor
Suunto D6 Dive Computer — Ceiling, ceiling zone, floor and decompression range diagram (page 62)
Fig. 44 · Ceiling, ceiling zone, floor and decompression range

The depth of the ceiling and floor will depend on your dive profile. The ceiling depth will be fairly shallow when you enter the decompression mode, but if you remain at depth, it will move downward and the ascent time will increase. Likewise, the floor and ceiling may change upwards while you are decompressing. When conditions are rough, it may be difficult to maintain a constant depth near the surface. In such cases, it is more manageable to maintain an additional distance below the ceiling, to make sure that the waves do not lift you above the ceiling. Suunto recommends that decompression takes place deeper than 4 m/13 ft, even if the indicated ceiling is shallower.

Page 63 of the Suunto D6 Dive Computer user manual — Display below the floor
Page 63 · click to enlarge
Page 63

Display below the floor The blinking ASC TIME and an upward pointing arrow indicate that you are below the floor. You should start your ascent immediately. The ceiling depth is shown on the left side, and the minimum total ascent time on the right side, of the center window. Below is an example of a decompression dive without Deep Stops, below the floor.

Suunto D6 Dive Computer — Display below the floor diagram (page 63)
Fig. 45 · Display below the floor

UPWARD POINTING ARROW, BLINKING ASC TIME AND AN ALARM TELL YOU TO ASCEND. MINIMUM TOTAL ASCENT TIME INCLUDING SAFETY

STOP IS 4 MINUTES. CEILING IS AT 3 M.

Display above the floor When you ascend above the floor, the ASC TIME display stops blinking and the upward pointing arrow disappears. Below is an example of a decompression dive above the floor.

Page 64 of the Suunto D6 Dive Computer user manual — Display at the ceiling zone
Page 64 · click to enlarge
Page 64
Suunto D6 Dive Computer — Display at the ceiling zone diagram (page 64)
Fig. 46 · Display at the ceiling zone

UPWARD POINTING ARROW HAS DISAPPEARED AND ASC TIME LABEL HAS STOPPED BLINKING, MEANING YOU ARE IN

Decompression will now begin, but is very slow. You should therefore continue your ascent.

Display at the ceiling zone When you reach the ceiling zone, the display will show you two arrows pointing at each other (the “hour glass” icon). Below is an example of a decompression dive at the ceiling zone.

Suunto D6 Dive Computer — Display at the ceiling zone diagram (page 64)
Fig. 47 · Display at the ceiling zone

TWO ARROWS POINT AT EACH OTHER “HOUR GLASS”. YOU ARE IN THE OPTIMUM CEILING ZONE AT 3 M. AND YOUR MINIMUM ASCENT TIME IS

Page 65 of the Suunto D6 Dive Computer user manual — Display above the ceiling
Page 65 · click to enlarge
Page 65

During the decompression stop, ASC TIME will count down towards zero. When the ceiling moves upwards, you can ascend to the new ceiling. You may surface only after the ASC TIME and CEILING labels have disappeared, which means that the decompression stop and any Mandatory Safety Stop have been completed. You are advised, however, to stay until the STOP sign has also disappeared. This indicates that the three minute Recommended Safety Stop has also been completed.

Display above the ceiling If you ascend above the ceiling during a decompression stop, a downward pointing arrow will appear and a continuous beeping starts.

Suunto D6 Dive Computer — Display above the ceiling diagram (page 65)
Fig. 48 · Display above the ceiling

DECOMPRESSION DIVE, ABOVE CEILING. NOTE DOWNWARD POINTING ARROW, ER WARNING AND ALARM. YOU SHOULD IMMEDIATLY (WITHIN

In addition, an Error warning (Er) reminds you that you have only three minutes to correct the situation. You must immediately descend to, or below, the ceiling. If you continue to violate the decompression, the dive computer will go into a permanent Error Mode. In this mode, the instrument can only be used as a depth gauge and timer. You must not dive again for at least 48 hours. (See Section 5.7. Error conditions).

6.2. Diving in NITROX mode (DIVEean) NITROX mode (DIVEean) is the second dive mode available in Suunto D6 and is used when using oxygen- enriched gas mixtures.

Page 66 of the Suunto D6 Dive Computer user manual — 6.2.1. Before diving in NITROX mode
Page 66 · click to enlarge
Page 66

6.2.1. Before diving in NITROX mode If set to the NITROX mode, the correct oxygen percentage of the gas in your cylinder must always be entered into the computer to ensure correct nitrogen and oxygen calculations. The dive computer adjusts its mathematical nitrogen and oxygen calculation models accordingly. The dive computer will not accept fractional percentage values of oxygen concentration. Do not round up fractional percentages. For example, 31.8% oxygen should be entered as 31%. Rounding up will cause nitrogen percentages to be understated and will affect decompression calculations. If you want to adjust the computer to provide more conservative calculations, use the personal adjustment feature to affect decompression calculations, or reduce the PO2 setting to affect oxygen exposure according to the entered O2% and PO2 values. Calculations based on nitrox use result in longer no-decompression times and shallower maximum depths than diving with air. As a safety precaution, the oxygen calculations in the computer are made with an oxygen percentage of 1% + set O2% . When the dive computer is set in NITROX mode, the Dive Planning mode calculates using the O2% and PO2 values that are currently in the computer. To set the nitrox mixes, refer to Section 5.8.3. Setting the nitrox values.

Default nitrox settings In NITROX mode, the Suunto D6 allows you to set 1 or 2 nitrox mixes containing 21- 99% oxygen.

Page 67 of the Suunto D6 Dive Computer user manual — 6.2.2. Oxygen displays
Page 67 · click to enlarge
Page 67

In the NITROX mode, the default setting for MIX1 is standard air (21% O2). It remains in this setting until the O2% is adjusted to any other percentage of oxygen (22% - 100%). The default setting for maximum oxygen partial pressure is 1.4 bar, however you are able to set it in the range of 0.5 - 1.6 bar. MIX2 is set to OFF by default. To set MIX2 , refer to Section 6.2.4. Gas change and multiple breathing gas mixes. Oxygen percentages and maximum oxygen partial pressures for MIX2 are stored permanently.

NOTE If MIX2 is set OFF, the computer will retain the manually entered values for the oxygen percentage and maximum oxygen partial pressure for MIX1 for about two hours, after which it will revert to the default settings. If MIX2 is set ON, the computer will retain the settings until changed. If MIX2 or MIX3 are set to off and have an oxygen content of value of 21%, the computer will retain the manually entered values for the oxygen percentage and maximum oxygen partial pressure for MIX1 for about 2 hours, after which it will revert to default settings. If MIX2 or MIX3 have an oxygen content of 22% or greater, the computer will retain the settings until changed.

6.2.2. Oxygen displays When NITROX mode is activated, the display will show the information in the figure below. In NITROX mode, the maximum operational depth is calculated based on set O2% and PO2 values.

Page 68 of the Suunto D6 Dive Computer user manual — 6.2.2. Oxygen displays
Page 68 · click to enlarge
Page 68
Suunto D6 Dive Computer — 6.2.2. Oxygen displays diagram (page 68)
Fig. 49 · 6.2.2. Oxygen displays

NITROX DIVE MODE ACTIVATION. MAXIMUM OPERATIONAL DEPTH BASED ON SET O2% (21%) AND PO2 (1.4 BAR) IS 56.7 M.

  • If set to NITROX mode, the Suunto D6 will additionally show on the alternative display:
  • the oxygen percentage, labeled O 2 %
  • the set oxygen partial pressure limit, labeled PO 2
  • the current oxygen toxicity exposure, labeled OLF
  • maximum depth
  • current time
  • water temperature
  • dive time
Suunto D6 Dive Computer — 6.2.2. Oxygen displays diagram (page 68)
Fig. 50 · 6.2.2. Oxygen displays

DOWN BUTTON TOGGLES BETWEEN O2, MAXIMUM DEPTH AND CURRENT TIME.

Page 69 of the Suunto D6 Dive Computer user manual — 6.2.3. Oxygen limit fraction (OLF)
Page 69 · click to enlarge
Page 69
Suunto D6 Dive Computer — 6.2.3. Oxygen limit fraction (OLF) diagram (page 69)
Fig. 51 · 6.2.3. Oxygen limit fraction (OLF)

UP BUTTON TOGGLES BETWEEN PO2, OLF, DIVE TIME AND WATER TEMPERATURE.

6.2.3. Oxygen limit fraction (OLF) If set to NITROX mode, in addition to tracking the diver's exposure to nitrogen, the instrument tracks the exposure to oxygen. These calculations are treated as entirely separate functions. The dive computer calculates separately for Central Nervous System oxygen toxicity (CNS) and Pulmonary Oxygen toxicity, the latter measured by the addition of Oxygen Toxicity Units (OTU). Both fractions are scaled so that the maximum tolerated exposure for each is expressed as 100%. The Oxygen Limit Fraction (OLF) displays only the value of the higher of the two calculations. The oxygen toxicity calculations are based on the factors listed in Section 9.3 “Oxygen exposure”.

Page 70 of the Suunto D6 Dive Computer user manual — 6.2.4. Gas change and multiple breathing gas mixes
Page 70 · click to enlarge
Page 70

6.2.4. Gas change and multiple breathing gas mixes One of Suunto D6’s special features is the possibility to set an additional nitrox mix to be used during a dive. This feature can be activated by setting the MIX2 to ON and entering other parameters in the same way as with the primary gas. Mix 2 settings are held until you change them (they will not return to default settings automatically). A dive is always started with MIX1. During the dive, the Suunto D6 enables you change to another enabled mix, which is within the set maximum oxygen partial pressure. The tissue calculation during the dive is based on the mix you have selected. The Suunto D6 allows gas changes to enabled gas mixes during the dive. Gas changes are made by following the procedure below:

Suunto D6 Dive Computer — 6.2.4. Gas change and multiple breathing gas mixes diagram (page 70)
Fig. 52 · 6.2.4. Gas change and multiple breathing gas mixes

CHANGING GAS MIX. SCROLL THROUGH ENABLED MIXES BY PRESSING THE UP OR DOWN BUTTONS. SELECT NEW MIX BY

NOTE Mix number, O2%, and PO2 for the mixes are shown when scrolling. If the set PO2 limit is exceeded , it will be shown with the PO2 value blinking. The dive computer does not allow you to change to a gas whose set PO2 is exceeded. In such a case, the mix is shown but cannot be selected.

Page 71 of the Suunto D6 Dive Computer user manual — 6.3. Diving in GAUGE mode (DIVEgauge)
Page 71 · click to enlarge
Page 71

NOTE If no button is pressed in 15 seconds, the dive computer will go back to the dive display without changing the gas mix. Upon ascent, the computer prompts you to change gas when the PO2 level you have set for the next mix allows a gas change.The prompt is an audible 3 beeps and the current O2 mix starts to blink.

6.3. Diving in GAUGE mode (DIVEgauge) If set to GAUGE mode, the dive computer can be used as a bottom timer or as a freediving instrument. In the GAUGE mode, the total dive time is always displayed in minutes in the lower right corner. In addition, a Dive Timer in the center window displays time in minutes and seconds. The center window Dive Timer is activated at the start of the dive and it can be reset during the dive and used as a stopwatch by pressing the SELECT button.

Suunto D6 Dive Computer — 6.3. Diving in GAUGE mode (DIVEgauge) diagram (page 71)
Fig. 53 · 6.3. Diving in GAUGE mode (DIVEgauge)

BY PRESSING THE SELECT BUTTON DURING A DIVE, A BOOK- MARK IS WRITTEN IN THE PROFILE MEMORY, THE DIVE TIMER IS RESET,

Page 72 of the Suunto D6 Dive Computer user manual — 6.3. Diving in GAUGE mode (DIVEgauge)
Page 72 · click to enlarge
Page 72
Page 73 of the Suunto D6 Dive Computer user manual — 7. AFTER DIVING
Page 73 · click to enlarge
Page 73

7. AFTER DIVING

7.1. At the surface Once back at the surface, Suunto D6 continues to provide post-dive safety information and alarms. Calculations to enable repetitive dive planning also help to maximize diver safety.

7.1.1. Surface interval An ascent to any depth shallower than 1.2 m/4 ft will cause the DIVING display to be replaced by the SURFACE display:

Suunto D6 Dive Computer — 7. AFTER DIVING diagram (page 73)
Fig. 54

IT IS 6 MINUTES SINCE YOU SURFACED FROM A 35-MINUTE DIVE. THE MAXIMUM DEPTH WAS 21.5 M. THE PRESENT DEPTH IS 0.0 M. THE AIRPLANE SYMBOL AND NO-FLY VALUE INDICATE THAT YOU SHOULD NOT FLY FOR 14 HOURS, 28 MINUTES. THE DIVER ATTENTION SYMBOL INDICATES THAT

  • Or, in the alternative displays, the following information will be shown:
  • maximum depth of last dive in meters/feet
  • dive time of last dive in minutes, shown as DIVE TIME
  • the current time, shown as TIME
  • the current temperature in °C/°F If set to NITROX mode, the following information will also be shown:
  • the oxygen percentage labeled O 2 %
Page 74 of the Suunto D6 Dive Computer user manual — 7.1.2. Dive numbering
Page 74 · click to enlarge
Page 74
  • the oxygen partial pressure labeled PO 2
  • the current oxygen toxicity exposure labeled OLF

7.1.2. Dive numbering Several repetitive dives are considered to belong to the same repetitive dive series when the dive computer has not counted the no-fly time to zero. Within each series, the dives are given individual numbers. The first dive of the series will be numbered as DIVE 1, the second as DIVE 2, the third as DIVE 3, etc. If you start a new dive with less than 5 minutes of surface interval time, the dive computer interprets this as a continuation of the previous dive and the dives are considered to be the same. The diving display will return, the dive number will remain unchanged, and the dive time will begin where it left off. After 5 minutes on the surface, subsequent dives are, by definition, repetitive. The dive counter displayed in the Planning mode will increment to the next number if another dive is made.

Table 7.1. Alarms

Indication Symbol on display

Diver Attention Symbol - Attenuated RGBM model set

Diver Attention Symbol - Extend Surface Interval

Do Not Fly Symbol

Violated Decompression Ceiling

Page 75 of the Suunto D6 Dive Computer user manual — 7.1.3. Repetitive dive planning
Page 75 · click to enlarge
Page 75

7.1.3. Repetitive dive planning The Suunto D6 includes a dive planner that allows you to review the no-decompression limits on a subsequent dive, taking the residual nitrogen loading of previous dives into consideration. The Dive Planning mode is explained in Section Dive Planning mode (MEMplan) in Section 7.1.5. MEMORY mode.

  • 7.1.4. Flying after diving The no-fly time is shown in the center window next to the airplane image. Flying or traveling to a higher altitude should be avoided at any time when the computer is counting down the no-fly time. The no-fly time is always at least 12 hours, or equivalent to the so-called desaturation time (if longer than 12 hours). For desaturation times lower than 70 minutes, no nofly time is given. In the Permanent Error mode and GAUGE mode the no-fly time is 48 hours. The Divers Alert Network (DAN) recommends the following on no-fly times:
  • A minimum surface interval of 12 hours would be required in order to be reasonably assured a diver will remain symptom free upon ascent to altitude in a commercial jetliner (altitude up to 2,400 m/8,000 ft)
  • Divers who plan to make daily, multiple dives for several days, or make dives that require decompression stops, should take special precautions and wait for an extended interval beyond 12 hours before a flight. Further, the Undersea and Hyperbaric Medical Society (UHMS) suggests divers using standard air cylinders and exhibiting no symptoms of decompression illness wait 24 hours after their last dive to fly in an aircraft with cabin pressure up to 2,400 m/8,000 ft. The only two exceptions to this recommendation are:
Page 76 of the Suunto D6 Dive Computer user manual — 7.1.5. MEMORY mode
Page 76 · click to enlarge
Page 76
  • If a diver has less than 2 hours total accumulated dive time in the last 48 hours, a 12 hour surface interval before flying is recommended
  • Following any dive that required a decompression stop, flying should be delayed for at least 24 hours, and if possible, for 48 hours
  • Suunto recommends that flying is avoided until all the DAN and UHMS guidelines, as well as the dive computer’s no-fly conditions, are satisfied

7.1.5. MEMORY mode The memory options include a dive planner (MEMplan), dive logbook (MEMlog) and dive history (MEMhis). They are accessed from DIVE mode and you can toggle between them by using the UP/DOWN buttons.

Suunto D6 Dive Computer — 7.1.5. MEMORY mode diagram (page 76)
Fig. 55 · 7.1.5. MEMORY mode

The dive time and date are registered in the Logbook memory. Always check before diving that the time and date are correctly set, especially after traveling between different time zones.

Dive Planning mode (MEMplan) The Dive Planning mode displays no-decompression times for a new dive, taking into account the effects of previous dives.

Page 77 of the Suunto D6 Dive Computer user manual — 7.1.5. MEMORY mode
Page 77 · click to enlarge
Page 77

When entering the MEMplan mode, the display first briefly shows the remaining desaturation time before going into plan mode. By pressing the UP/DOWN buttons, you can scroll the no-decompression limits in 3 m/10 ft increments ending at 45 m/150 ft. No-decompression limits longer than 99min are displayed as “—“.

Suunto D6 Dive Computer — 7.1.5. MEMORY mode diagram (page 77)
Fig. 56 · 7.1.5. MEMORY mode

WHEN ENTERING THE MEMPLAN MODE THE DISPLAY FIRST BRIEFLY SHOWS THE REMAINING DESATURATION TIME BEFORE GOING INTO PLAN MODE. USE UP AND DOWN BUTTONS TO SCROLL DIFFERENT NO-DECOMPRESSION LIMITS.

NO-DECOMPRESSION LIMITS LONGER THAN 99 MINUTES ARE DISPLAYED AS “–”.

  • The Planning mode takes into account the following information from previous dives:
  • any calculated residual nitrogen
  • all dive history for the past four days The no-decompression times given for different depths will therefore be shorter than before your first “fresh” dive. You can exit the planning mode by pressing the MODE button.
Page 78 of the Suunto D6 Dive Computer user manual — Dive numbering shown during dive planning
Page 78 · click to enlarge
Page 78

Higher Altitude and conservative Personal Adjustment settings will shorten the no- decompression time limits. These limits at different Altitude and Personal Adjustment setting selections are explained in Section 5.9.4. Diving at altitude and in Section 5.9.5. Personal adjustments

Dive numbering shown during dive planning Dives belong to the same repetitive dive series if the instrument was still counting down the no-fly time at the beginning of the dive. The surface interval must be at least 5 minutes for a dive to be considered a repetitive dive. Otherwise, it is considered a continuation of the same dive. The dive number will not change and the dive time will continue where it left off. (See also Section 7.1.2. Dive numbering ).

Dive logbook (MEMlog) The Suunto D6 has a very sophisticated, high capacity Logbook and Profile Memory. The data is recorded in the profile memory based on the selected sample rate. Dives shorter than the recording interval are not registered (see Section 5.8.5. Setting the sample rate).

Page 79 of the Suunto D6 Dive Computer user manual — Dive numbering shown during dive planning
Page 79 · click to enlarge
Page 79

The END OF LOGS text is displayed between the oldest and most recent dive. The following information will be shown on three pages:

Suunto D6 Dive Computer — Dive numbering shown during dive planning diagram (page 79)
Fig. 57 · Dive numbering shown during dive planning

THERE ARE THREE PAGES OF LOGBOOK DIVE INFORMATION. USE SELECT BUTTON TO SCROLL BETWEEN LOGBOOK PAGES I, II, AND III. THE DATA OF

  • Page I, main display
  • Maximum depth (NOTE! Depending on the sampling rate, the reading may differ from the maximum depth reading of the Dive History up to 0.3 m/1 ft.)
  • date of dive
  • type of dive (Air, Ean, Gauge)
  • dive start time
  • dive number
  • oxygen percentage for Mix1
  • total dive time Page II
  • maximum depth
Page 80 of the Suunto D6 Dive Computer user manual — Dive history (MEMhis)
Page 80 · click to enlarge
Page 80
  • surface time before previous dive
  • warnings Page III
  • depth/time profile of the dive
  • real-time water temperature The memory will retain approximately the last 36 hours of dive time. After that, when new dives are added, the oldest dives are deleted. The contents of the memory will remain when the battery is changed (providing that the battery has been replaced according to the instructions).

Dive history (MEMhis) The Dive History is a summary of all the dives recorded by the dive computer. The following information will be shown on the display:

Suunto D6 Dive Computer — Dive history (MEMhis) diagram (page 80)
Fig. 58 · Dive history (MEMhis)

DIVE HISTORY DISPLAY. TOTAL NUMBER OF DIVES, DIVE HOURS AND MAXIMUM DEPTH.

Page 81 of the Suunto D6 Dive Computer user manual — 7.1.6. Suunto Dive Manager (SDM)
Page 81 · click to enlarge
Page 81

The Dive History Memory can hold a maximum of 999 dives and 999 diving hours. When these maximum values are reached, the counters will start again from zero.

  • 7.1.6. Suunto Dive Manager (SDM) Suunto Dive Manager (SDM) is optional PC software that greatly enhances the functionality of your Suunto D6. With the SDM software, you can download dive data from your dive computer to your PC. You can then view and organize all the data recorded with your Suunto D6. You can also plan dives, print copies of your dive profiles and upload your dive logs to share with your friends at <a href="http://SuuntoSports.com" rel="nofollow noopener" target="_blank">SuuntoSports.com</a>. You can always download the latest version of Suunto Dive Manager from <a href="http://www.suunto.com" rel="nofollow noopener" target="_blank">www.suunto.com</a> or <a href="http://www.SuuntoSports.com" rel="nofollow noopener" target="_blank">www.SuuntoSports.com</a> Please check for updates regularly as new features are constantly being developed. The following data is transferred to your PC:
  • depth profile of the dive
  • dive time
  • preceding surface interval time
  • dive number
  • dive start time (year, month, day and time)
  • dive computer settings
  • oxygen percentage settings and maximum OLF (in NITROX mode)
  • tissue calculation data
Page 82 of the Suunto D6 Dive Computer user manual — 7.1.7. SuuntoSports.com
Page 82 · click to enlarge
Page 82
  • real-time water temperature
  • additional dive information (e.g. SLOW and Mandatory Safety Stop violations, Diver Attention Symbol, Bookmark, Surfaced Mark, Decompression Stop Mark, Ceiling Error Mark, Gas Change)
  • dive computer serial number
  • personal information (30 characters) Using SDM, you are able to enter setup options such as:
  • input a personal, 30-character field into the Suunto D6
  • reset the Dive History’s maximum depth to zero It is also possible to manually add comments, multimedia and other personal information to the PC-based dive data files.

7.1.7. SuuntoSports.com When you have dived and transferred your dive data to your Suunto Dive Manager, you can share your best experiences with other diving enthusiasts at SuuntoSports.com. It's a free and open Internet community where you can compare your underwater experiences with other Suunto users and learn from each other. SuuntoSports.com includes three sections. In My Suunto you can register your dive computer and manage your membership profile. The section also contains a personal event calendar.

Page 83 of the Suunto D6 Dive Computer user manual — 7.1.7. SuuntoSports.com
Page 83 · click to enlarge
Page 83

The Communities section is meeting a place for smaller groups of SuuntoSports.com members. Here you can create and manage your own communities and search for others. All communities have a home page that lists the latest group activities. Community members can also use group-specific bulletin boards and calendars, create their own link lists and group activities. All registered SuuntoSports.com users automatically become members of the ‘World of Suunto Sports’ community. The Sport forums include sport-specific news, bulletin boards, event calendars, ranking lists and discussions. You can also exchange experiences and read travel reports written by other members. To learn more about SuuntoSports.com’s functions and activities, visit the site, try them and, if necessary, use the site Help. The Help is available on the right side of the bar that divides the screen.

Page 84 of the Suunto D6 Dive Computer user manual — 8. CARE AND MAINTENANCE
Page 84 · click to enlarge
Page 84

8. CARE AND MAINTENANCE

The Suunto D6 dive computer is a sophisticated precision instrument. Though designed to withstand the rigors of scuba diving, you must handle your Suunto D6 with care, and follow the advice below on how to maximize its service life.

8.1. Water contacts and buttons Contamination or dirt on the water contacts/connector or buttons may prevent the automatic activation of the DIVE mode and cause problems during data transfer. Therefore, it is important that the water contacts and push buttons are kept clean. If the water contacts of the instrument are active (AC-text remains on the display) or the DIVE mode activates on its own, the reason is probably contamination or invisible marine growth that may create an unwanted electric current between the contacts. It is important that the dive computer is carefully washed in fresh water after the day's diving is completed. The contacts can be cleaned with fresh water and, if necessary, a mild detergent and a soft brush.

  • 8.2. Care of your dive computer
  • NEVER try to open the case of the dive computer
  • Have your dive computer serviced every two years or after 200 dives (whichever comes first) by an authorized Suunto representative. This service will include a general operational check, replacement of the battery, and a water resistance check. The service requires special tools and training, so do not attempt to carry out any service that you are not competent to perform
  • If moisture appears inside the case, have the instrument checked immediately by your Suunto representative 84
Page 85 of the Suunto D6 Dive Computer user manual — 8.3. Maintenance
Page 85 · click to enlarge
Page 85
  • If you detect scratches, cracks or other such flaws on the display that may impair its durability, have it replaced immediately by your Suunto representative
  • Check the strap and the buckle for flaws. If needed, have them replaced by your Suunto representative
  • Wash and rinse the unit in fresh water after every use
  • Protect the unit from shock, extreme heat, direct sunlight, and chemical corrosion. The dive computer cannot withstand the impact of heavy objects like scuba cylinders, nor chemicals like gasoline, cleaning solvents, aerosol sprays, adhesive agents, paint, acetone, alcohol etc. Chemical reactions with such agents will damage seals, the case, and the finish
  • Store your dive computer in a dry place when you are not using it
  • The dive computer displays a battery symbol as a warning when the power gets too low. When this happens, the instrument should not be used until the battery has been replaced. Also refer to Section 5.9. Activation and pre-checks
  • Do not fasten the strap of your dive computer too tightly. You should be able to insert your finger between the strap and your wrist

8.3. Maintenance If left without care for an extended period, a thin film, often invisible to the naked eye, will cover the unit. Much like the build-up on the glass of an aquarium, this film is the result of organic contaminants found in both salt and fresh water. Suntan oil, silicone spray and grease will speed up this process. As a result of this build-up, moisture will be trapped next to the water contacts and will prevent your Suunto D6 from operating properly. The water contacts can be cleaned with a small brush (e.g. toothbrush).

Page 86 of the Suunto D6 Dive Computer user manual — 8.4. Water resistance inspection
Page 86 · click to enlarge
Page 86
  • CAUTION
  • Do not use compressed air to blow water off the unit.
  • Do not use solvents or other cleaning fluids that might cause damage.
  • Do not test or use the dive computer in pressurized air.

8.4. Water resistance inspection The water resistance of the unit must be checked after replacing the battery or after other service operations. The check requires special equipment and training. You must frequently check the display for any sign of leaks. If you find moisture inside your dive computer, there is a leak. A leak must be corrected without delay, as moisture will seriously damage the unit, even beyond repair. Suunto does not take any responsibility for damage caused by moisture in the dive computer, if the instructions of this manual have not been carefully followed. In the event of a leak, immediately take the dive computer to an authorized Suunto representative.

Page 87 of the Suunto D6 Dive Computer user manual — 8.5. Battery replacement
Page 87 · click to enlarge
Page 87

8.5. Battery replacement

All history and profile data, as well as the altitude, personal, and alarm settings, will remain in the dive computer memory after the battery change. However, the clock time and time alarm setting are lost. In the NITROX Mode, the nitrox settings also revert back to default settings (MIX1 21 % O2, 1.4 bar PO2, MIX2 OFF).

Page 88 of the Suunto D6 Dive Computer user manual — 9. TECHNICAL DATA
Page 88 · click to enlarge
Page 88

9. TECHNICAL DATA

  • 9.1. Technical specifications Dimensions and weight:
  • Diameter: 50.0 mm/1.97 in
  • Thickness: 16.0 mm/0.61 in
  • Weight: 113g/3.98 oz Depth gauge:
  • Temperature compensated pressure sensor
  • Salt water calibrated, in fresh water the readings are about 3% smaller (calibrated in compliance with EN 13319)
  • Maximum depth of operation: 100 m/328 ft (complying with EN 13319)
  • Accuracy: ± 1% of full scale or better from 0 to 80 m/262 ft at 20°C/68°F (complying with EN 13319)
  • Depth display range: 0 to 150 m/492 ft
  • Resolution: 0.1 m from 0 to 100 m/1 ft from 0 to 328 ft Temperature display:
  • Resolution: 1°C/1.5°F
  • Display range: -20 to +50°C/-9 to +122°F
  • Accuracy: ± 2°C/± 3.6°F within 20 minutes of temperature change Calendar clock:
  • Accuracy: ± 25 s/month (at 20°C/68°F)
  • 12/24 h display Other displays:
Page 89 of the Suunto D6 Dive Computer user manual — 9. TECHNICAL DATA
Page 89 · click to enlarge
Page 89
  • Displays only in NITROX mode:
  • Oxygen %: 21 - 99
  • Oxygen partial pressure display: 0.2 - 3.0 bar, depending on the limit setting
  • Oxygen Limit Fraction: 1 - 200% with 1% resolution Logbook/dive profile memory:
  • Recording interval: 20 seconds adjustable (1,10,20,30,60s). Records the maximum depth and minimum temperature of each interval
  • Memory capacity: approximately 36 hours of diving with 20 second recording interval
  • Depth accuracy: 0.3 m/1 ft Operating conditions:
  • Normal altitude range: 0 to 3,000 m/10,000 ft above sea level
  • Operating temperature: 0°C to 40°C/32°F to 104°F
  • Storage temperature: -20°C to +50°C/ -4°F to +122°F It is recommended that the instrument be stored in a dry place at room temperature.
  • Tissue calculation model:
  • Suunto Deep Stop RGBM algorithm (developed by Suunto and Bruce R. Wienke, BSc, MSc, PhD)
  • 9 tissue compartments
  • Tissue compartment halftimes: 2.5, 5, 10, 20, 40, 80, 120, 240 and 480 minutes (on gassing). The off gassing halftimes are slowed down
Page 90 of the Suunto D6 Dive Computer user manual — 9. TECHNICAL DATA
Page 90 · click to enlarge
Page 90
  • Reduced gradient (variable) "M" values based on diving habit and dive violations. The "M" values are tracked up to 100 hours after a dive
  • The EAN and oxygen exposure calculations are based on recommendations by R.W. Hamilton, PhD and currently accepted exposure time limit tables and principles Battery:
  • One 3 V lithium battery: CR 2450
  • Battery storage time (shelf life): Up to three years
  • Replacement: Every three years, or more often depending on dive activity
  • Life expectancy at 20°C/68°F:
  • 0 dives/y - 3 years
  • 100 dives/year – 2 years
  • 300 dives/year – 1.5 years The following conditions have an effect on the expected battery lifetime:
  • The length of the dives
  • The conditions in which the unit is operated and stored (e.g. temperature/cold conditions). Below 10°C/50°F the expected battery lifetime is about 50-75% of that at 20°C/68°F
  • The use of the backlight and audible alarms
  • The use of the compass
  • The quality of the battery. (Some lithium batteries may exhaust unexpectedly, which cannot be tested in advance)
  • The time the dive computer has been stored until it gets to the customer. (The battery is installed in the unit at the factory)
Page 91 of the Suunto D6 Dive Computer user manual — 9.2. RGBM
Page 91 · click to enlarge
Page 91
  • 9.2. RGBM The Suunto Reduced Gradient Bubble Model (RGBM) is a modern algorithm for predicting both dissolved and free gas in the tissues and blood of divers. It was developed in co-operation between Suunto and Bruce R. Wienke BSc, MSc, PhD. It is based on both laboratory experiments and diving data, including data from DAN. It is a significant advance on the classical Haldane models, which do not predict free gas (microbubbles). The advantage of Suunto RGBM is additional safety through its ability to adapt to a wide variety of situations. Suunto RGBM addresses a number of diving circumstances outside the range of dissolved-gas-only models by:
  • Monitoring continuous multiday diving
  • Computing closely spaced repetitive diving
  • Reacting to a dive deeper than the previous dive
  • Adapting to rapid ascents which produce high microbubble (silent-bubble) buildup
  • Incorporating consistency with real physical laws for gas kinetics
Page 92 of the Suunto D6 Dive Computer user manual — 9.2.1. Suunto RGBM adaptive decompression
Page 92 · click to enlarge
Page 92
  • 9.2.1. Suunto RGBM adaptive decompression The Suunto RGBM algorithm adapts its predictions of both the effects of microbubble build-up and adverse dive profiles in the current dive series. It also changes these calculations according to the personal adjustment you select. The pattern and speed of decompression at the surface is adjusted according to microbubble influence. On repetitive dives, adjustment may also be applied to the maximum allowable nitrogen overpressure in each theoretical tissue group. Depending on the circumstances, Suunto RGBM will adapt the decompression obligations by doing any or all of the following:
  • Reducing No-decompression Stop dive times
  • Adding Mandatory Safety Stops
  • Increasing Decompression Stop times
  • Advising an extended surface interval (Diver Attention symbol) Diver Attention Symbol – Advice to Extend Surface Interval. Some patterns of diving cumulatively add a higher risk of DCI; for example, dives with short surface intervals, repetitive dives deeper than earlier ones, multiple ascents, and substantial multiday diving. When this is detected, in addition to adapting the decompression algorithm, the Suunto RGBM model will in some circumstances also advise, with the Diver Attention Symbol, that you extend your surface interval.
Page 93 of the Suunto D6 Dive Computer user manual — 9.2.2. No-decompression limits
Page 93 · click to enlarge
Page 93

9.2.2. No-decompression limits The no-decompression limits displayed by the dive computer for the first dive to a single depth (see Table 9.1, No-decompression time limits for various depths (m) and Table 9.2, No-decompression time limits for various depths (ft).), are slightly more conservative than those permitted by the U.S. Navy tables.

Table 9.1. No-decompression time limits for various depths (m)

No-decompression time limits (mins) for various depths (m) for the first

dive of a series

Personal Mode / Altitude Mode Depth

(m) P2/A2 P2/A1 P2/A0 P1/A2 P1/A1 P1/A0 P0/A2 P0/A1 P0/A0

Show 27 more labels / short text on this page
9 12 15 · -- 124 72 · 163 89 57 · 130 67 43 · 163 89 57 · 130 67 43 · 96 54 35 · 130 67 43 · 96 54 35 · 75 45 29 · 18 21 24 · 52 37 29 · 39 29 24 · 30 23 19 · 39 29 24 · 30 23 19 · 5 20 16 · 30 23 19 · 25 20 16 · 21 15 12 · 27 30 33 · 23 18 13 · 18 14 11 · 15 12 9 · 18 14 11 · 15 12 9 · 15 12 9
Page 94 of the Suunto D6 Dive Computer user manual — 9.2.2. No-decompression limits
Page 94 · click to enlarge
Page 94
Suunto D6 Dive Computer — 9.2.2. No-decompression limits diagram (page 94)
Fig. 59 · 9.2.2. No-decompression limits

No-decompression time limits (mins) for various depths (m) for the first

(m) P2/A2 P2/A1 P2/A0 P1/A2 P1/A1 P1/A0 P0/A2 P0/A1 P0/A0

Table 9.2. No-decompression time limits for various depths (ft)

Suunto D6 Dive Computer — 9.2.2. No-decompression limits diagram (page 94)
Fig. 60 · 9.2.2. No-decompression limits

No-decompression time limits (mins) for various depths (ft) for the first

(ft) P2/A2 P2/A1 P2/A0 P1/A2 P1/A1 P1/A0 P0/A2 P0/A1 P0/A0

Page 95 of the Suunto D6 Dive Computer user manual — 9.2.3. Altitude diving
Page 95 · click to enlarge
Page 95

No-decompression time limits (mins) for various depths (ft) for the first

dive of a series

Personal Mode / Altitude Mode Depth

(ft) P2/A2 P2/A1 P2/A0 P1/A2 P1/A1 P1/A0 P0/A2 P0/A1 P0/A0

120 130 140 150

10 9 7 6

9 7 6 5

8 6 5 4

9 7 6 5

8 6 5 4

6 5 4 4

8 6 5 4

6 5 4 4

5 4 4 3

9.2.3. Altitude diving The atmospheric pressure is lower at high altitudes than at sea level. After traveling to a higher altitude, you will have additional nitrogen in your body, compared to the equilibrium situation at the original altitude. This "additional" nitrogen is released gradually over time and equilibrium is restored. It is recommended that you acclimatize to a new altitude by waiting at least three hours before making a dive. Before high-altitude diving, the instrument must be set to the Altitude Adjustment mode to adjust the calculations for the new altitude. The maximum partial pressures of nitrogen allowed by the mathematical model of the dive computer are reduced according to the lower ambient pressure.

Show 7 more labels / short text on this page
90 100 110 · 22 17 13 · 18 14 11 · 15 11 9 · 18 14 11 · 15 11 9 · 15 11 9
Page 96 of the Suunto D6 Dive Computer user manual — 9.3. Oxygen exposure
Page 96 · click to enlarge
Page 96

As a result, the allowed no-decompression-stop limits are considerably reduced.

  • 9.3. Oxygen exposure The oxygen exposure calculations are based on currently accepted exposure time limit tables and principles. In addition to this, the dive computer uses several methods to conservatively estimate the oxygen exposure. For example:
  • the displayed oxygen exposure calculations are raised to the next higher percentage value
  • for recreational scuba diving, the recommended upper limit of 1.4 bar PO 2 is used as a default
  • the CNS % limits up to 1.6 bar are based on 1991 NOAA Diving Manual limits
  • the OTU monitoring is based on the long-term daily tolerance level and the recovery rate is reduced Oxygen related information displayed by the dive computer is also designed to ensure that all warnings and displays occur at the appropriate phases of a dive. For example, the following information will be shown before and during a dive when the computer is set in NITROX mode:
  • the selected O 2 % on the alternative display
  • OLF% alternative display for either CNS% or OTU% (whichever is larger)
  • audible alarms are given and the OLF value starts to blink when the 80% and 100% limits are exceeded
  • audible alarms are given and the actual PO 2 value blinks when it exceeds the preset limit
  • in dive planning, the maximum depth according to the O 2 % and maximum PO 2 selected 96
Page 97 of the Suunto D6 Dive Computer user manual — 10. INTELLECTUAL PROPERTY
Page 97 · click to enlarge
Page 97

10. INTELLECTUAL PROPERTY

10.1. Copyright This user's manual is copyrighted and all rights are reserved. It may not, in whole or in part, be copied, photocopied, reproduced, or translated to any media without prior written consent from Suunto.

10.2. Trademark Suunto, D6, Consumed Bottom Time (CBT), Oxygen Limit Fraction (OLF), Suunto Reduced Gradient Bubble Model (RGBM), and Continuous Decompression and their logos are all registered or unregistered trademarks of Suunto. All rights are reserved.

10.3. Patent notice This product is protected by the following patents and patent applications: US 5,845,235 and US11/152,075. Other patents have been applied for.

Page 98 of the Suunto D6 Dive Computer user manual — 11. DISCLAIMERS
Page 98 · click to enlarge
Page 98

11. DISCLAIMERS

11.1. User’s responsibility This instrument is intended for recreational use only. Suunto D6 must not be used for obtaining measurements that require professional or industrial precision.

11.2. Limits of liability and ISO 9001 compliance Suunto Oy does not assume any responsibility for losses or claims by third parties, which may arise through the use of this device. Due to continuous product development, the Suunto D6 is subject to change without notice. ISO 9001 Suunto Oy’s Quality Assurance System is certified by Det Norske Veritas to be in accordance with ISO 9001 in all Suunto Oy's operations (Quality Certificate No. 96- HEL-AQ-220).

Page 99 of the Suunto D6 Dive Computer user manual — 11.3. After sales service
Page 99 · click to enlarge
Page 99

11.3. After sales service If a claim under warranty appears to be necessary, return the product, freight prepaid, to your Suunto representative, who is responsible for having your product repaired or replaced. Depending on the requirements in your country, include your name, address, proof of purchase and/or Warranty card, which can be found at the back of this manual. The claim will be honored and the product repaired or replaced at no charge and returned in what your Suunto representative determines a reasonable amount of time, provided that all necessary parts are in stock. All repairs that are not covered under the terms of this warranty will be made at the owner's expense. This warranty is non- transferable from the original owner. You can locate your local Suunto representative at www.suunto.com

Page 100 of the Suunto D6 Dive Computer user manual — 12. WARRANTY
Page 100 · click to enlarge
Page 100

12. WARRANTY

This Suunto dive computer is warranted against defects in workmanship and materials for a period of two years after purchase to the original owner subject to and in accordance with the terms and conditions set forth below: The dive computer should be serviced and repaired only by an authorized Suunto representative. This warranty does not cover damage to the product resulting from improper usage, improper maintenance, neglect of care, alteration or unauthorized repair. This warranty will automatically become void if proper preventive maintenance procedures have not been followed as outlined in the use and care instructions for this product. All implied warranties, including but not limited to the implied warranties of merchantability and fitness for a particular purpose, are limited from the date of purchase and in scope to the warranties expressed herein. Suunto shall not be liable for loss of use of the product or other incidental or consequential costs, expenses or damage incurred by the purchase. All warranties not stated herein are expressly disclaimed. Some states do not allow the exclusion or limitation of implied warranties of consequential damages, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

Page 101 of the Suunto D6 Dive Computer user manual — 12. WARRANTY
Page 101 · click to enlarge
Page 101

This warranty does not cover any representation or warranty made by representatives beyond the provisions of this warranty. No Suunto representative is authorized to make any modifications to this warranty or to make any additional warranty. Battery replacement is not covered by this warranty. This User's Guide should be kept with your dive computer. Suunto's dive computers and wristop computers can be registered online at www.suunto.com Registering your unit makes it quicker and easier for us to help you if you ever need to send your product for servicing, or if you need information about using your unit from our Global Help Desk.

Page 102 of the Suunto D6 Dive Computer user manual — 13. DISPOSAL OF THE DEVICE
Page 102 · click to enlarge
Page 102

13. DISPOSAL OF THE DEVICE

Please dispose of the device in an appropriate way, treating it as electronic waste. Do not throw it in the garbage. If you wish, you may return the device to your nearest Suunto representative.

Page 103 of the Suunto D6 Dive Computer user manual — GLOSSARY
Page 103 · click to enlarge
Page 103

GLOSSARY

Altitude dive A dive made at an elevation greater than 300 m/1000 ft above sea level. Ascent rate The speed at which the diver ascends toward the surface. ASC RATE Abbreviation for ascent rate. Ascent time The minimum amount of time needed to reach the surface on a decompression stop dive. ASC TIME Abbreviation for ascent time. Ceiling On a decompression stop dive, the shallowest depth to which a diver may ascend based on computed nitrogen load. CNS Abbreviation for central nervous system toxicity. Central nervous system toxicity Toxicity caused by oxygen. Can cause a variety of neurological symptoms. The most important of which is an epileptic-like convulsion which can cause a diver to drown. CNS% Central nervous system toxicity limit fraction. Also note Oxygen Limit Fraction Compartment See "Tissue group". DAN Abbreviation for Divers Alert Network. DCI Abbreviation for decompression illness. Decompression Time spent at a decompression stop, or range, before surfacing, to allow absorbed nitrogen to escape naturally from tissues Decompression range On a decompression stop dive, the depth range between the floor and the ceiling within which a diver must stop for some time during ascent.

Page 104 of the Suunto D6 Dive Computer user manual — GLOSSARY
Page 104 · click to enlarge
Page 104

Decompression illness Any of a variety of maladies resulting either directly or indirectly from the formation of nitrogen bubbles in tissues or body fluids, as a result of inadequately controlled decompression. Commonly called "the bends" or "DCI". Dive series A group of repetitive dives between which the dive computer indicates some nitrogen loading is present. When nitrogen loading reaches zero the dive computer deactivates. Dive time Elapsed time between leaving the surface to descend, and returning to the surface at the end of a dive. EAD Abbreviation for equivalent air depth. EAN Abbreviation for enriched air nitrox. Enriched air nitrox Also called nitrox or Enriched Air = EANx. Air that has some oxygen added. Standard mixes are EAN32 (NOAA Nitrox I = NN I) and EAN36 (NOAA Nitrox II = NN II). Equivalent air depth Nitrogen partial pressure equivalent table. Floor The deepest depth during a decompression stop dive at which decompression takes place. Half time After a change in ambient pressure, the amount of time required for the partial pressure of nitrogen in a theoretical compartment to go half way from its previous value to saturation at the new ambient pressure. Multi level dive A single or repetitive dive that includes time spent at various depths and whose no decompression limits are therefore not determined solely by the maximum depth attained.

Page 105 of the Suunto D6 Dive Computer user manual — GLOSSARY
Page 105 · click to enlarge
Page 105

Nitrox In sports diving, refers to any mix with a higher fraction of oxygen than standard air. NOAA United States National Oceanic and Atmospheric Administration. No decompression time The maximum amount of time a diver may remain at a particular depth without having to make decompression stops during the subsequent ascent. No decompression dive Any dive which permits a direct, uninterrupted ascent to the surface at any time. NO DEC TIME Abbreviation for no decompression time limit. OEA = EAN = EANx Abbreviations for oxygen enriched air nitrox. OLF Abbreviation for oxygen limit fraction. OTU Abbreviation for oxygen tolerance unit. Oxygen tolerance unit Used to measure the whole-body-toxicity. Oxygen limit fraction A term used by Suunto for the values displayed in the oxygen toxicity bargraph. The value is either the CNS% or the OTU%. O2% Oxygen percentage or oxygen fraction in the breathing gas. Standard air has 21% oxygen. Oxygen partial pressure Limits the maximum depth to which the nitrox mixture can be safely used. The maximum partial pressure limit for enriched air diving is 1.4 bar. The contingency partial pressure limit is 1.6 bar. Dives beyond this limit risk immediate oxygen toxicity. PO2 Abbreviation for oxygen partial pressure. RGBM Abbreviation for Reduced Gradient Bubble Model.

Page 106 of the Suunto D6 Dive Computer user manual — GLOSSARY
Page 106 · click to enlarge
Page 106

Reduced Gradient Bubble Model Modern algorithm for tracking both dissolved and free gas in divers. Repetitive dive Any dive whose decompression time limits are affected by residual nitrogen absorbed during previous dives. Residual nitrogen The amount of excess nitrogen remaining in a diver after one or more dives. SURF TIME Abbreviation for surface interval time. Surface interval time Elapsed time between surfacing from a dive and beginning a descent for the subsequent repetitive dive. Tissue group Theoretical concept used to model bodily tissues for the construction of decompression tables or calculations. Whole-body toxicity Another form of oxygen toxicity, which is caused by prolonged exposure to high oxygen partial pressures. The most common symptoms are irritation in the lungs, a burning sensation in the chest, coughing and reduction of the vital capacity. Also called Pulmonary Oxygen Toxicity. See also OTU.

Page 107 of the Suunto D6 Dive Computer user manual — GLOSSARY
Page 107 · click to enlarge
Page 107
Suunto D6 Dive Computer — GLOSSARY diagram (page 107)
Fig. 61
Page 108 of the Suunto D6 Dive Computer user manual — GLOSSARY
Page 108 · click to enlarge
Page 108
Model of Serial Wristop computernumber:

Place of purchase/Store name

Store City Store Country

Store stamp with date of purchase

Show 6 more labels / short text on this page
Date of purchase · Name · Address · City Country · Telephone E-mail · Signature
Page 109 of the Suunto D6 Dive Computer user manual — GLOSSARY
Page 109 · click to enlarge
Page 109
Page 109 of the Suunto D6 Dive Computer user manual — GLOSSARY
Page 110 of the Suunto D6 Dive Computer user manual — GLOSSARY
Page 110 · click to enlarge
Page 110
Page 110 of the Suunto D6 Dive Computer user manual — GLOSSARY
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Suunto D6 Dive Computer

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.