READ AND SAVE THESE INSTRUCTIONS WHEN USING ELECTRICAL APPLIANCES,
ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
COOL TAP WATER. PLACE HUMIDIFIER ON A FLAT, LEVEL SURFACE. DO NOT PLACE NEAR HEATING DEVICES. KEEP THE CORD AWAY FROM HEATED SURFACES AND
AREAS WHERE IT CAN BE STEPPED ON OR TRIPPED OVER.
PLUG HUMIDIFIER INTO POLARIZED 120 VOLT AC OUTLET ONLY. BE SURE UNIT IS PLUGGED IN FIRMLY AND COMPLETELY. TURN HUMIDIFIER OFF AND UNPLUG WHEN NOT IN USE AND BEFORE
CLEANING. NEVER OPERATE HUMIDIFIER WITH A DAMAGED CORD OR PLUG. IF IT IS NOT WORKING PROPERLY, OR IT HAS BEEN DROPPED OR DAMAGED, RETURN IT TO THE APPLIANCE SERVICE STATION FOR EXAMINATION, REPAIR, OR POSSIBLE

ELECTRICAL OR MECHANICAL ADJUSTMENT 6. DO NOT ADD MEDICATION OF ANY TYPE INTO THE WATER IN THE RESERVOIR. DO NOT COVER VENTS
OR LOUVERS OR PLACE ANYTHING OVER THEM WHILE HUMIDIFIER IS OPERATING. NEVER DROP
OR INSERT ANY OBJECT INTO ANY OPENING. 7. SUPERVISION IS RECOMMENDED WHEN HUMIDIFIER IS USED NEAR CHILDREN, INVALIDS OR PETS. 8. DO NOT REMOVE HUMIDIFIER MOTOR ASSEMBLY WHILE HUMIDIFIER IS OPERATING. 9. DO NOT TILT OR TIP HUMIDIFIER OR ATTEMPT TO EMPTY OR FILLWHILE IN OPERATION. 10. TURN HUMIDIFIER OFF AND UNPLUG WHEN WATER RESERVOIR IS EMPTY AND BEFORE
CLEANING OR MOVING HUMIDIFIER. 1 11. TO GUARD AGAINST ELECTRICAL SHOCK, DO NOT IMMERSE HUMIDIFIER MOTOR ASSEMBLY IN WATER OR OTHER LIQUIDS. 12. DO NOT USE OUTDOORS.
1 13. DO NOT USE HUMIDIFIER OTHER THAN FOR HUMIDITY CONTROL.

Please refer to the directions below for inserting and removing the humidifier motor assembly. Unit may make vibrating noise if motor assembly is not
placed properly on humidifier water reservoir.
To remove motor assembly from water reservoir lift motor assembly directly
upwards from water reservoir. To insert motor assembly onto water reservoir set motor assembly gently on ridge of water reservoir. Be sure motor
assembly cannot move around on water reservoir.
humidifier when not in use, and before cleaning, rinsing, filling or moving. Unit will reach maximum output after about five uses. If greater output is desired, warm tap water may be used.
full. Do not fill the reservoir higher than the top line. The half full line is to be used for running the humidifier half the
hours when you fill it up, and you only want to fill 10 hours, simply fill your humidifier to the first line.) Do not add
medication of any type to the water in the container. After filling, replace
top as explained above.
Full Line


To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
This humidifier contains a removable moisture Impeller Tip Impeller Tlp Holder control impeller tip. The impeller tip comes already l
placed on the units impeller stem (Figure 2).
=. .
:
:
.- The impeller tip enables you to control the
‘. . .
r :
Figure 2’ Impeller Stem amount of moisture the unit puts into the air. If
you would like to increase moisture output, carefully lift motor
assembly from water reservoir and remove impeller tip and
place on tip holder on under side of humidifier cap. (Figure 3). figure 3
This enables more water to flow through impeller stem and increases the
amount of moisture that is put into the air. To decrease moisture output just slide impeller tip back on to impeller stem.
especially cleaning.
! moisture output of your humidifier.
built up in impeller stem.
* · $

(Always Clean Humidifier Before Storing).
l/4 cup household bleach. Seal humidifier opening with a soft cloth to prevent moisture from escaping. 3. Plug unit into 120 volt outlet and run for 30 minutes with opening sealed. Operate unit in an empty bathtub to avoid damage to surrounding area from bleach water. 4. Remove cloth from opening, empty bucket, and thoroughly rinse until bleach smell is gone.
5. Wipe humidifier dry. Failure to properly clean your humidifier will result in the build up of harmful bacteria and mold. In areas where tap water contains excessive mineral matter, a white dust may accumulate in the area near the humidifier. This white dust can be readily removed with a cloth or vacuum cleaner or be completely eliminated by using distilled water. The white dust is not a defect in the humidifier, but is due to minerals suspended in the water. DO NOT use any type of water
conditioning tablet as it may cause other problems.
add medication of any type to the
/ water in the container.
DO NOT use impeller stem as a handle.
This could damage your
humidifier.
Do not allow humidifier to stand with water unused; this could cause growth of fungi.
It will not harm unit to continue running without water, if the water is used up during normal operation. However, do not leave humidifier plugged in when not in use.

All Sunbeam humidifiers are built with the safety of our customers as a
priority. Our Safety Glow plastic glows in the dark, letting you know the location of your humidifier at night. The length and intensity of the glow will vary depending upon the amount and quality of light the product absorbs dur-
ing the day. to achieve the greatest glow at night, place in direct sunlight dur-
ing the day. The brightness of the glow will be more intense for the first 1-2
hours in the dark. The glow will then diminish, but still remain at a level noticeable to the human eye. Our safety thermostat motors automatically turn off if any overheating occurs. There is no changing of fuses with a Sunbeam humidifier. If overheating occurs just unplug the unit from outlet
for a short period of time, plug back into outlet and resume operation
of humidifier.
2 Year Limited Warranty
Congratulations on your recent purchase of a quality Sunbeam product. We are confident that our product will perform well and therefore warrant to you, as the original retail purchaser, for a period of 2 years from the date of original
purchase, that your new product will be free of mechanical and electrical
defects in material and workmanship.
If your product is covered during the warranty period, we will repair or replace a new or refurbished unit of your new product (at our option) without cost to
you, which will be your exclusive remedy under this warranty. Please do not
return this product to the place of purchase; doing so may delay the processing of your claim and our repair of your product. Simply send your product postage
prepaid, with proof of purchase and a short description of the problem directly to our factory service center at the following address: SUNBEAM PRODUCTS, Sunbeam Appliance Service Station, 95 WL Runnels Industrial Drive, Dock M5,
Hattiesburg, MS 39401. California residents may call the following number to locate the nearest authorized service center: I-800-597-5978.

Our warranty for your product will not cover normal wear of parts, damage resulting from negligent use or misuse of the product, use of improper voltage
or current, use contrary to operating instructions, glass breakage (if applica- ble), or disassembly, repair, or alteration by any person other than an autho- rized service station. Any implied warranty of merchantability or fitness for a particular purpose on your product is limited to the duration of this written warranty. We shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on your product.
Some states do not allow limitations on how long an implied warranty lasts
or the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
01999 Sunbeam Corporation or its affiliated companies, all rights reserved. SUNBEAM@ and HEALTH AT
HOME@ are registered trademarks of Sunbeam Corporation or its affiliated companies. Distributed by Sunbeam Products,
Inc.,
Raton, Florida 33431. Imported by Sunbeam Corporation. The
product you buy may differ slightly from the one shown on this carton due to continuing product development. Questions or comments, please call
customer service at I-800-435-1250.
IJULY
Boca
Owners and our team usually reply within a day — and your question helps the next person too.