900 AIR CLEANER AND IONIZER
OPERATING INSTRUCTIONS
CAUTION:
READ AND SAVE THESE INSTRUCTIONS.
Call I-800-526-2832 Mon.-Fri. 8 a.m. - 4 p.m. Centrai Time

LOCATION
Your Sunbeam 900 Air Cleaner has been designed to
Remove the plastic bag covering your air cleaner. Select the location for your air cleaner with electrical outlet nearby. Do not use an extension cord to supply
let you enjoy a refreshing experience in clean air living.
power to your air cleaner. Remember, the air cleaner must be placed SO that air can freely circulate into the front grill and out of the top grill. (Figure 1) Never place your air cleaner on soft surfaces (such as beds, sofas or carpet), near computers or next to sources of heat
Airborne particles are removed from air passing through the unit by the process of electrostatic precipi-
tation and an activated charcoal filter.
roughly before your air cleaner is operated.
(such as stove tops, ovens, etc.).
Retain your owner’s manual for future refer- ence.
HOW THE SUNBEAM 900 AIR CLEANER AND IONIZER WORKS

The air around you is filled with thousands of particles of air pollution. Some of the pollutants (dust, smoke and lint) are visible to the naked eye, but most of the
“_-I-._ Plug the cord into any standard household electrical outlet. (See data label on bottom of your air cleaner for electrical specifications and power consumption.) Turn the unit on by sliding the ON/OFF switch to the desired speed. (DAILY USE, MEDIUM or SUPER CLEAN, Figure 3) Until your air cleaner is adequately
_“. -.
pollutants (pollen and bacteria, to name a few) are microscopic in size.
Polluted air enters the air cleaner through the front of the air cleaner. (Figure 1) As shown in Figure 2, the fan
pulls in dirty air and the Pre-Filter (#l) traps large parti- cles (hair, lint, etc.). The smaller particles (dust, smoke,
broken in, the speed should be set on SUPER CLEAN for 1 minute initially before switching to desired speed. Your electronic air cleaner is designed for continuous
pollen) in the dirty air receive a positive electrical charge as they pass through the ionizing section. (#2)
operation -- peak efficiency is obtained when the air cleaner remains on constantly. For best results, Select “DAILY USE” setting.
The positively charged particles then enter the collect- ing section (#3) which uses a series of alternately charged aluminum plates to attract and retain the par- ticles. It works Ii ke a powerful magnet and the particles
The “FAN ONLY” speed is provided to assist in the dry
cycle after cleaning the cell. NOTE: You may notice an occasional, infrequent
remain there through natural adhesion until removed by the washing process. The air then passes through a charcoal filter (#4) that helps remove household odors. Next, the negative ion generator (#5) freshens stale air.
Sharp snapping sound coming from your unit. This is a normal occurrence called “arcing” and results as large particles of dust are
Finally, electronically cleaned air passes back into the room through the top grill. (Figure 1)
collected in the ionizing-collecting cell. Should prolonged or continuous arcing occur, the Electronic Collecting Cell should be thorough- ly cleaned and dried. (See “TO Clean Electronic Collecting Cell”.)







The outside of the cabinet can be cleaned by using a soft, clean, damp cloth. Never immerse the unit in water.
The Electronic Collecting Cell Will need cleaning about every four to eight weeks when your air cleaner
is in constant use. Turn off the air cleaner and unplug it trom the electri- cal power source.

Remove cabinet lid by depressing tab located under lid overhang. (See Figure 11 for exact tab placement)
Slide lid forward from base and lift off. (Figure 4)
Push Cell Locking Latch (Figure 5) away from Cell while lifting Cell out of the cabinet using the two small
handles on top of the Cell. (Figure 5 & Figure 6)
Slide Pre-Filter upward from the front of the Cell (Fig- ure 7) and remove.
Slide Charcoal Filter upward from back of the Cell (Figure 6) and remove.




ACTIVATED CHARCOAL FILTER HELPS REMOVE
HOUSEHOLD ODORS
Washing the Charcoal Filter with soap and water Will destroy its ability to adsorb odor.
Odor adsorption effectiveness Will gradually deterio- rate and the Charcoal Filter should be replaced every three months. These filters are available in your retail store or through a reorder form enclosed with this unit.

Shake as much water out of the cell as possible.
be taken to avoid damaging wires and metal
Replace Cell in the unit as described below and oper- ate unit in “FAN ONLY” position for a minimum of one
plates. Do not wash Charcoal Filter. Do not wash Electronic Collecting Cell in dishwasher.
hour to insure cell is thoroughly dry.
Slide out Pre-Filter located on front of the Cell. Rinse thoroughly with clean warm water. Set aside to dry.
ION GENERATOR NEEDLE
Use dishwashing detergent and the hottest water available to make a good soaking solution.
Make sure the air cleaner is turned off and unplugged from the electric power source for approximately 1
minute before cleaning needle.
The negative ion generator needle is located in the
before proceeding to washing instructions.
right rear of the air cleaner (Figure 11) and should be cleaned at least every 60 days.
Completely immerse the Cell and soak for 20 to 30 minutes. . After the Cell has soaked sufficiently, it should be
Simply use cotton swab dipped in alcohol and wipe off the dirt from the needle. Using a dry cotton swab, make
shaken vigorously in water until clean. (Figure 9)
sure the needle is dry.
Thoroughly rinse both sides of the cell. If a sprayer is
available, spray with water. (Figure 10) Check to make sure the cell plates are clean. Carefully wipe with a Q-tip and alcohol along the ionizing wires.

Repeat the above last 3 paragraphs if necessary.




ment of the filters into the Cell and for replacing the Cell into the unit. Unit will not operate
properly if the Cell is not replaced correctly.
Slide the Pre-Filter in the slots provided in the front of the Cell. (Figure 12)
Slide the Charcoal Filter in the slots provided in the
back of the Cell. (Figure 13)
Using the cell handles (Figure 14), align the Cell with the ribs (Figure 14) on the inside cabinet wall. Gently slide Cell into place.

s/
Replace the cabinet top by positioning over the unit. (Figure 15) Gently slide top forward until the top drops into place. (Figure 16) Slide top backward until flush

with the back of the unit. (Figure 17)
Operate the unit in “FAN ONLY” position for a min- imum of one hour to insure the cell is thoroughly dry.
operating the unit immediately after cleaning the Cell and should stop after a few minutes of
operation. If cleaning the Cell does not alleviate excessive arcing, refer to the Troubleshooting Section on page 5.





/ E L E C T R O N I C
C O L L E C T I N G









Many times service problems that appear to be major can be solved easily. The chart below lists potential problems and how to correct them. Remember, check the simple things first.







0 2 PRE-FILTER




To order Replacement Parts, write to Appliance Service Center, P.O. Box 70,6892 Purvis, MS, 39475.


900 AIR CLEANER AND IONIZER
OWNER’S
MANUAL
This product is warranted for one year from the date of purchase against electrical and mechanical defects in material and workman- ship. If the unit fails to operate during this period, return it, prepaid, to Appliance Service Station, 117 Central Industrial Row,Purvis,Mississ- ippi, 39475, for repair or replacement without charge at the manu-
facturer’s option. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Pan NO. 61801 (144958-001)
@Sunbeam-Oster Household Products, Distributed by Sunbeam-Oster Household Products, Schaumburg. IL 60173
Committed To Our Environment . . . Printed on Recycled Paper
(:)
Household Products · Made in America · Printed in USA
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.